Class J Dual Element Time-Delay Fuses

advertisement
Prices as of April 27, 2016. Check Web site for most current prices.
Dual Element Time-Delay
Class J Fuses
Company
Information
Terminal Blocks
Specifications
EDISON JDL Class J fuses are
among the most popular current limiting time-delay fuses
available. Their small physical size and high performance
characteristics make Class J
fuses ideal for any space-limited
application.
JDL5
JDL40
ZIPLink
Connection
System
Interrupting Rating:
200,000 RMS Symmetrical Amps
Multi-wire
Connectors
Self-Certified Interruptin
Rating:
300,000 RMS Symmetrical Amps
Sensor Cables
and Connectors
Self-Certified DC Ratings:
Voltage Rating: JDL - 300 VDC
Interrupting Rating:
JDL - 20,000 Amperes DC
M12 Junction
Blocks
Panel Interface
Connectors
Current Limiting:
Class J Fuse
Wiring Duct
Cable Ties
Agency Approvals
Wire
• UL Listed, Class J, Guide JDDZ,
File E162363
• CSA Certified HRCI-J per C22.2,
No. 248.8
Applications
• Recommended for Type 2
(no damage) protection of IEC
style motor starters and
contactors.
• Use to protect lower interrupting
rated circuit breakers.
• All general purpose circuits with
inductive (high inrush) loads,
including motor and motor
branch circuits, and transformer
circuits. Also
suitable for lighting loads.
Bulk
Multi-conductor
Cables
Wire
Management
Products
CROSS REFERENCE
AJT
LITTELFUSE
LPJ
MERSEN
GOULD
BUSSMANN
EDISON
VOLTS
600 JDL
Power Supplies
DC Converters
Transformers
and Filters
JTD
URRENT LIMITING
JDL Dimensions
inches (mm)
DIMENSIONS
Cat No. JFL and JDL, Class J
Circuit Protection
Tools
Test
Equipment
Enclosures
Enclosure
Climate Control
110-200
225-400
450-600
Blade
Width
F
–
–
3/4
1-1/8
1-5/8
2
Mounting Hole Spacing
G
H
J
–
–
–
–
–
–
1/2
3-518
3/8
11/16
4-3/8
3/8
15/16
5-1/4
17/32
1
6
11/16
JDL Series Dimensions - Inches [mm]
A
B
2.25
0.81
[57.15] [20.6]
2.38
1.06
[60.5] [26.92]
4.63
1.13
[117.5] [28.6]
5.75
1.63
[146.1] [41.3]
7.13
2.13
[181]
[54]
8
2.5
[203.2] [63.5]
Safety: Electrical
Components
K
–
–
9/32
9/32
13/32
17/32
Blade
Width
70-100
Blade
Thickness
E
–
–
1/8
3/16
1/4
3/8
Blade
Thickness
35-60
Barrel
Length
D
–
–
2-5/8
3
3-3/8
3-314
C
D
E
F
G
H
J
K
–
–
–
–
–
–
–
–
Barrel
Length
1-30
Blade
Length
C
–
–
1
1-3/8
1-7/8
2-1/8
Blade
Length
Range
Max.
Dia.
B
13/16
1-1/16
1-1/18
1-5/8
2-1/8
2-5/8
Max. Dia.
Overall
Length
A
2-1/4
2-3/8
4-5/8
5-3/4
7-1/8
8
Overall
Length
Ampere
Rating
Range
1-30
35-60
70-100
110-200
225-400
450-600
Ampere
Rating
Rated
Part
AMP Voltage Pcs/ Package Price
Number Rating
Pkg Weight
AC Max
1
$129.00
JDL1
2
$129.00
JDL2
3
$129.00
JDL3
4
$135.00
JDL4
5
$129.00
JDL5
6
$129.00
JDL6
8
$135.00
JDL8
1.00 lb. $129.00
JDL10 10
$135.00
JDL12 12
10
$129.00
JDL15 15
$135.00
JDL17-5 17.5
$129.00
JDL20 20
$129.00
JDL25 25
$129.00
JDL30 30
$228.00
JDL35 35
$228.00
JDL40 40
$228.00
JDL45 45
2.00 lb
$228.00
JDL50 50
600V
60
$228.00
JDL60
70
$228.00
JDL70
80
$228.00
JDL80
5
1.70 lb
$244.00
JDL90 90
$228.00
JDL100 100
$96.00
JDL110 110
$90.00
JDL125 125
4.25 lb
$96.00
JDL150 150
$97.00
JDL175 175
$90.00
JDL200 200
$162.00
JDL225 225
$152.00
1
JDL250 250
$190.00
1.70 lb
JDL300 300
$165.00
JDL350 350
$152.00
JDL400 400
$253.00
JDL450 450
$253.00
2.80 lb
JDL500 500
600
$253.00
JDL600
Ampere Rating: 1–600 Amps
• Space saving dimensions
compared to Class R
• Dual-Element construction
provides superior time-delay to
pass harmless motor or
transformer surges
• High performance with fatiguefree cycling capabilities
• Extremely current limiting
JDL Series
Dual-element Time-delay Fuses
Wiring
Accessories
Voltage Rating: JDL - 600 VAC
JDL Features
JDL150
Power
Distribution
Blocks
Mounting Hole Spacing
–
–
–
–
–
–
–
–
1
[25.4]
1.38
[34.9]
1.88
[47.8]
2.13
[54]
2.63
[66.7]
3
[76.2]
3.38
[85.8]
3..75
[95.3]
0.13
[3.2]
0.19
[4.8]
0.25
[6.35]
0.38
[9.5]
0.75
[19.1]
1.13
[28.6]
1.63
[41.3]
2
[50.8]
0.5
[12.7]
0.69
[17.5]
0.94
[23.8]
1
[25.4]
3.63
[92.1]
4.38
[111.1]
5.25
[133.4]
6
[152.4]
0.38
[9.5]
0.38
[9.5]
0.56
[14.3]
0.75
[19.1]
0.28
[7.1]
0.28
[7.1]
0.41
[10.3]
0.53
[13.5]
Book 3 (14.3)
w w w. a u t o m a t i o n d i r e c t . c o m / c i r c u i t- p r o t e c t i o n
Circuit Protection
eCP-145
Safety: Protective
Wear
Terms and
Conditions
Prices as of April 27, 2016. Check Web site for most current prices.
Dual Element Time-Delay
Class J Fuses
Current Curves
600A
Ampere
Rating
200
40,000
30,000
100
80
60
10
7
6
3
20,000
10,000
8,000
6,000
AMPERE
RATING
60, 000
80, 000
100, 000
100
30, 000
40, 000
.1
.08
.06
20, 000
200
100
.2
400
300
6, 000
8, 000
10, 000
.4
.3
3, 000
4, 000
1
.8
.6
1,000
800
600
2, 000
2
A
2,000
600
800
1, 000
4
3
4,000
3,000
300
400
10
8
6
1
200
20
200, 000
40
30
TIME IN SECONDS
B
100,000
80,000
60,000
INSTANTANEOUS PEAK LET-THRU CURRENT IN AMPS
400A
200A
225A
125A
100A
15A
20A
30A
40A
50A
60A
300
10A
Cat. No. JDL (Amp) 600V
5A
Cat. No. JDL (Amp) 600V
3A
PEAK LET-THROUGH CURRENT CURVES
1A
AVERAGE TIME/CURRENT CURVE
RMS SYMMETRICAL CURRENTS IN AMPERES
A–B=ASYMMETRICAL AVAILALBE PEAK (2.3 X SYMM RMS AMPS)
.04
.03
4,000
3,000
AMPERE
RATING
2,000
1,000
800
600
400
300
A
200, 000
60, 000
80, 000
100, 000
30, 000
40, 000
20, 000
6, 000
8, 000
10, 000
3, 000
4, 000
100
2, 000
200
600
800
1, 000
400A
600A
—
—±
—
—
4,400
—
5,540
8,000
6,420
9,000
7,000
10,000
7,500
11,100
8,000
11,800
8,330
12,500
9,000
13,270
9,380
13,820
10,000 15,000
11,270 16,000
12,180 17,270
14,360 19,270
15,820 20,600
100
60
50
40
30
20
15
10,000
8,000
6,000
300
400
1,000
3,000
5,000
10,000
15,000
20,000
25,000
30,000
35,000
40,000
50,000
60,000
80,000
100,000
150,000
200,000
Let-Thru Current (Apparent RMS Symmetrical)
JDL (600V) Fuse Ratings
15A
30A
60A
100A
200A
270
470
750
—
—
370
670
1,130
1,640
2,360
450
800
1,420
1,910
2,760
550
1,000
1,730
2,450
3,520
625
1,220
1,890
2,850
4,000
700
1,330
2,120
3,090
4,400
750
1,440
2,250
3,400
5,000
800
1,530
2,370
3,650
5,140
820
1,600
2,580
3,780
5,430
900
1,640
2,670
4,000
5,640
925
1,760
2,790
4,470
6,000
1,000
1,850
3,000
4,670
6,420
1,160
2,000
3,220
5,000
7,400
1,220
2,150
3,520
5,360
7,950
1,400
2,460
4,000
6,170
9,000
1,560
2,640
4,450
7,000
10,000
200
20,000
200
*Prosp.
S.C.C.
600
400
40,000
30,000
100
Current-Limiting Effects
B
100,000
80,000
60,000
INSTANTANEOUS PEAK LET-THRU CURRENT IN AMPS
3,000
4,000
6,000
8,000
10,000
RMS SYMMETRICAL CURRENT IN AMPERES
2,000
600
800
1,000
300
400
200
60
80
100
30
40
20
6
8
10
2
1
.01
3
4
.02
RMS SYMMETRICAL CURRENTS IN AMPERES
A–B=ASYMMETRICAL AVAILABLE PEAK (2.3 X SYMM RMS AMPS)
*RMS Symmetrical Amperes Short-Circuit Current.
NOTE:Data derived from Current Limiting Curves.
Book 3 (14.3)
eCP-146
Circuit Protection
1 - 8 0 0 - 633 - 0 4 0 5
Prices as of April 27, 2016. Check Web site for most current prices.
Selection Guide
Line Overview
Company
Information
Terminal Blocks
The fuse selection guide below is a general summary of the
specifications included for each fuse type. This selection guide
does not include the many variables that can exist for specific
situations such as local codes, unusual temperature, or other
operating conditions. When selecting fuses, be sure to comply with any applicable PUBLIC SAFETY standards that apply to
Overcurrent Protection Devices (OPD).
The Edison family of fuses, fuse blocks and fuse holders is divided into two classes:
1. Current Limiting: Class CC, Class J, Class L, Class RK, Class T
2. General Purpose: Class M Midget and Small Dimension
Edison Fuses Selection Guide and General Specifications
Description
Class J
Fuse Type Fast-Acting Time-Delay
Part Number
JHL
JDL
Voltage
Rating
Amp Rating
Interrupting
Rating
Current
Limiting
Agency
Approvals
Dimensions
600VAC
450VDC
Current Limiting
Class RK1
Class T
Class RK5
Time-Delay
ECNR
ECSR LENRK LESRK
TJN
250VAC
250VAC
600VAC 125 VDC*
600VAC 125VDC*
600VAC 300VAC
(1-200A) 300VDC* (10-60A) 300VDC* 160 VDC
300VDC*
250VDC*
250VDC*
(15-600A)
(201-600A)
(70-600A)
1 - 600
1 - 600
3 - 600
10 - 600
5 - 600
Class CC
Fast-Acting Fast-Acting
TJS
LCU
HCLR
600VAC
600V
600VAC
300VDC
(15-20A)
1 - 600
601 - 1200
Time-Delay
HCTR
0.5 - 30
EDCC
600VAC
300VDC
600VAC (0.5-2.25A)
(20–30A)
0.25 - 30
0.5 - 30
Class RK5
Class RK1
Class T
Class L
* Self-certified DC ratings
Edison Fuses Selection Guide and General Specifications
General Purpose – Midget
Fuse Type
Fast-Acting
Part
Number
Voltage
Rating
MCL
MOL
Time-Delay
MEQ
MEN
250 VAC
to 30A)
600 VAC 250 VAC 500 VAC 250 VAC (0.5
125VDC:
(0.5 to 30A)
Amp Rating 0.5 to 50 0.5 to 30 0.25 to 30 0.5 to 30
Interrupting 100,000
10,000 RMS Amps
RMS Amps
Rating
Current
N/A
Limiting
Agency
Approvals
ABC
UL Listed to 248.14, File E162443
CSA Cert. C22.2 Part 59.2, LR 700489
0.5 to 30
Fast-Acting Glass
AGC
GMA
250VAC:
250VAC
(0.1 to 10A) (0.063 - 3A)
32VAC:
125VAC
(15 to 30A) (4 - 15A)
0.10 to 30
0.063 to 15
Medium Time- Time-Delay Time-Delay Fast-Acting
Delay Glass Ceramic
Glass
Glass
S500
TimeDelay
Glass
GMC
MDA
MDL
S506
250VAC
(0.5 - 3A)
125VAC
(4 - 10A)
250VAC
125VDC
(20A)
250VAC:
(0.0625
to 8A)
32VAC:
(10 to 20A)
250VAC
250VAC
0.5 to 10
0.5 to 20
0.0625 to 20
0.032 to 10
0.25 to 6.3
See specifications table on product pages
UL Listed standard 248-14
UL Listed Guide and File nos.
Designed to UL/CSA 248-14
(ABC 0.25-20 A):
UL Listed, Guide JDYX, File
(AGC 1/100-10 A)
JDYX and E19180
E19180 63mA-6A
UL Recognition Guide and UL Recognition, Guide JDYX2,
File nos. (ABC 20-30A):(AGC File E19180, 7A-15A
11-30)
CSA Certified, File
JDYX2 and E19180
053787_C_000,
CSA Certification Record No: 63mA-6A Class 1422-01
053787 C 000 and Class No:
1422 01 and 1422 30
0.197” x 0.788”
(5mm x 20mm)
UL Listed standard 248-14
UL Listed Card:
MDA 2/10-20A ,
MDL 1/16-8A
(Guide JDYX, File E19180
UL Recognized Card:
MDA 25-30A MDL 9-30A
(Guide JDYX2, File
E19180)
CSA Certification Card:
MDA 2/10-15A
(Class No. 1422-01)
L Recognized Guide
U
JDYX2, File E19180
Semko Approval
VDE Approval
BSI Approval
IMQ Approval
RoHS compliant
1/4” x 1-1/4”,
(6.3mm x 32mm)
0.197” x 0.788”
(5mm x 20mm)
Book 3 (14.3)
w w w. a u t o m a t i o n d i r e c t . c o m / c i r c u i t- p r o t e c t i o n
Wiring Duct
Bulk
Multi-conductor
Cables
Wire
Management
Products
Power Supplies
DC Converters
Transformers
and Filters
Tools
Test
Equipment
Enclosures
Safety: Electrical
Components
Safety: Protective
Wear
Terms and
Conditions
N/A
1/4” x 1-1/4”,
(6.3mm x 32mm)
Panel Interface
Connectors
Enclosure
Climate Control
RoHS
Dimensions ferrule (in): 13/32 length (in): 1-1/2
M12 Junction
Blocks
Circuit Protection
General Purpose – Small Dimension Electronic
Fast-Acting
Ceramic
Sensor Cables
and Connectors
Wire
Class CC
UL Listed
Class J
UL Listed
Guide JDDZ Class J
UL Listed,
File E162363 Guide JDDZ UL Listed, Class RK, Guide JDDZ,
UL Listed, Class T,
Std. 248-10 UL Listed to 248.4, Class CC,
CSA Certified File E162363 File E162363
Guide JDDZ, File E162363
CSA Certified, Guide JDDZ, File E162363,
HRCI-J per CSA Certified CSA Certified HRCI-R per C22.2, No. 248.12, CSA Certified HRCI-T per
HRC-L C22.2
certified HRCI-MISC per C22.2
C22.2,
HRCI-J per File 700489
C22.2, No. 248.12, File 53787, No. 248.10, CSA
No. 248.8
C22.2, No. (LENRK CSA File 053787)
Class 1422-02 & 1422-82
Class 1422-02, No. 248.4, File 700489
File 700489 248.8
File 53787
RoHS
File 700489
compliant
See product specification pages.
ferrule (in): 13/32, length (in): 1-1/2
Description
ZIPLink
Connection
System
Cable Ties
200,000 RMS Symmetrical Amps
Class J
Wiring
Accessories
Multi-wire
Connectors
Class L
Extremely Fast-Acting
Power
Distribution
Blocks
Circuit Protection
eCP-143
Prices as of April 27, 2016. Check Web site for most current prices.
Fuse Blocks for Class J Fuses
Description
Specifications
For use with Edison JDL class J fuses
Construction: T hermoplastic,
UL Flammability; 94V-0
Terminal type:
• C = Box lug type
• CR = Box lug type, with retaining clip
• P = Pressure plate. Clip reinforcin
springs are standard on fuseblocks
rated 100A and above.
Voltage Ratings: 600 Volts AC
Ampere Ratings: 0.50 - 600 Amps
Short-circuit current Rating: 200,000 RMS
Symmetrical Amps
Agency Approvals
• UL Listed, UL 512, Guide IZLT, File E14853
• CSA, certified, C22.2 No. 39, Class 6225-01,
File 47235
J60060-1C
Class J Fuse Blocks
Part Number
J60030-1P
J60030-2P
J60030-3P
J60060-1C
J60060-2C
J60060-3C
J60100-1CR
J60100-3CR
J60200-1CR
J60200-3CR
J60400-1CR
J60400-3CR
J60600-1CR
J60600-3CR*
J60030-2P
Amps Poles
Maximum
Wire Size
1
0.5 to 30
31 to 60
61 to 100
101 to 200
201 to 400
401 to 600
Wt.
Fig # Pcs/
Pkg (lbs.) Price
1
0.44
$18.50
2
0.35
$32.00
3
3
0.45
$48.50
1
1
0.44
$20.50
2
0.35
$39.00
3
3
0.55
$50.00
1
4
0.98
$34.50
2
2
3
1
3
1
3
1
3
#10-14 Cu
#2-14 Cu-Al
1/0-8 Cu-Al
1
1.55
$89.00
6
1.70
$133.00
9
6.70
$396.00
7
3.10
$202.00
10
14.0
$568.00
(2) 500MCM-4/0 8
Cu-Al
11
5.40
$328.00
8.0
$969.00
250MCM-6 Cu-Al
500MCM-4 Cu-Al
5
* Not UL, Please use (3) J60600-1CR to assemble a 3 pole UL Fuseblock
Class J Fuseholder Dimensions
J60030-3P
0.5 Amp to 60 Amp
2.42
[61.3]
1.70
[43.2]
.75
[19.1]
3.20
[81.3]
2.25
[57.2]
4.70
[119.4]
2.28
[58]
.30
[7.62]
2.25
[57.2]
.75
[19.1]
C
L
CL
4.01
[102]
6.28"
[160
1.50
[38.1]
Figure 1
Figure 2
Figure 3
Note: All dimensions shown in inches [mm]
Book 3 (14.3)
eCP-196
Circuit Protection
1 - 8 0 0 - 633 - 0 4 0 5
Prices as of April 27, 2016. Check Web site for most current prices.
Fuse Blocks for Class J Fuses
Terminal Blocks
0
3]
2]
Company
Information
4.70
.75
[19.1]
2.28
[58]
.30
[7.62]
61 Amp[119.4]
to 100 Amp
2.25
[57.2]
[49.4]
.94
[23.8]
[38.1]
1.58
[40.1]
Power
Distribution
Blocks
5
[127]
Wiring
Accessories
[5.6]
[12.7]
C
L
CL
4.01
[102]
6.28"
.22 [5.6]
Dia.
.5 [12.7]
C'Bore
ZIPLink
Connection
System
[160]
Multi-wire
Connectors
3.14
[79.8]
1.50
[38.1]
1.75
[44.5]
101 Amp to 200 Amp
3.1
[78.7]
3
[76.2]
2
[50.8]
3.06
[77.7]
Figure 4
.5
[12.7]
6.13
[155.7]
Wiring Duct
3
[76.2]
1.75
[44.5]
3.5
[88.9]
7.5
[191]
Cable Ties
.344 [8.74]
dia. hole through
.750 [19.1]
dia. c'bore
Wire
Bulk
Multi-conductor
Cables
4
[101.6]
1
[25.4]
.625
[15.9]
Power Supplies
10.51
[267]
9.00
[228]
6.00
[152.4]
.56
[14.2]
Wire
Management
Products
.750
[19.1]
Figure 7
Figure 6
201 Amp to 400 Amp
Panel Interface
Connectors
3.15
[80]
6.13
[155.7]
1.69
[42.9]
.34 [8.6]
dia.
M12 Junction
Blocks
Figure 5
8.31
[211.1]
7.00
[177.8]
.75
[19.1]
.31
[7.8]
.75 [19.1]
c'bore
Sensor Cables
and Connectors
1.5
[38.1]
DC Converters
4.00
[101.6]
Transformers
and Filters
Circuit Protection
7.50
[191]
.75 [19.1]
c'bore
.34 [8.6]
dia.
Tools
.344 [8.7]
dia. hole through
.750 [19.1]
dia. c'bore
2.0
[50.8]
.5
[12.7]
.50
[12.7]
Test
Equipment
Enclosures
Enclosure
Climate Control
Figure 9
Figure 8
1.00
[25.4]
Safety: Electrical
Components
401 Amp to 600 Amp
4
[101.6]
1.75
[44.5]
Safety: Protective
Wear
4.99
[126.7]
1.125
[28.6]
14.144
[359.3]
11.00
[279.4]
1 [25.4]
.56
[14.2]
Terms and
Conditions
4.99
[126.7]
3.25
[82.6]
8.875
[225.4]
2.38
[60.5]
.75 [19.1]
c'bore
.34 [8.6] dia.
Figure 10
8.88
[226] 2.88
[73.2]
Note: All dimensions shown in inches [mm]
.344 [8.7]
dia.
hole through
.750 [19.1] dia.
c'bore
Figure 11
.50
[12.7]
1.00
[25.4]
Book 3 (14.3)
w w w. a u t o m a t i o n d i r e c t . c o m / c i r c u i t- p r o t e c t i o n
Circuit Protection
eCP-197
Prices as of April 27, 2016. Check Web site for most current prices.
Modular Fuse Holders
for Class J Fuses
CH30J3
CH30J2I
CH30J1
Description
Specifications
• Choice of LED indicator or
non-indicating fuse holder
• Comes in standard 1-, 2- and 3-Pole
ganged assemblies where all fuses are
extracted simultaneously
• Meets requirements of IEC 60529 for
IP-20 finger safe rating
• 35 mm DIN rail and chassis (6-32 UNC Pan
Head recommended) mounting features
• Fuseholder wire ports dual wire rated
from 18 to 3 AWG
Agency Approvals
• Listed UL 512, Guide IZLT, File E14853
• CSA Certified per C22.2 Nos. 39
Class 6225-01, File LR47235
•C
E compliance for the European Union
Low Voltage Directive
Construction: Thermoplastic, with
tin-plated copper clip
UL Flammability: 94V-0
Voltage Ratings: 600 Volts AC
Ampere Ratings: 1 - 60 Amps
Interrupting Rating: 200,000 RMS Symmetrical Amps
Minimum Indicating Voltage
(neon lamp): 90 Volts
Nominal Operating Current
(neon lamp): 34 mA (460 VAC)
CH Series Modular Fuse Holders for Class J Fuses
Amp Part
Rating Number
CH30J1
CH30J2
CH30J3
30A
CH30J1I
CH30J2I
CH30J3I
CH60J1
CH60J2
CH60J3
60A
CH60J1I
CH60J2I
CH60J3I
Amps
0.5 to 30
31 to 60
Easy ID window
1
6
$125.83
Easy ID window
2
3
$175.76
Easy ID window
3
2
Neon indicator
1
6
Neon indicator
2
3
$201.73
Neon indicator
3
2
$193.46
Easy ID window
1
6
$169.55
Easy ID window
2
3
$198.64
Easy ID window
3
2
Neon indicator
1
6
Neon indicator
2
3
$237.12
Neon indicator
3
2
$215.27
A
B
C
D
E
F
G
H
CH30J in
(mm)
18 -1 AWG Single
18 -3 AWG Dual
75°C
Pcs/Pkg
Weight
(lbs.)
Poles
Price
$171.61
2.8
$147.70
$202.82
3.4
E
Dimensions
Dimension
Maximum
Wire Size
Type
$191.31
H
G
CH60J in (mm)
1.28 (32.5)
1.58 (40.0)
2.56 (65.0)
3.16 (80.0)
3.84 (97.5)
4.72 (120.0)
4.59 (116.6)
4.88 (124.0)
2.83 (71.8)
3.31 (84.1)
3.56 (90.4)
3.85 (97.9)
1.28 (32.5)
1.58 (40.0)
0.18 (4.44)
0.18 (4.44)
D F
3 POLE CLASS J
Modular Fuse Holder
A
B
C
Book 3 (14.3)
eCP-198
Circuit Protection
30A AND 60A
Ganging Assembly
1 - 8 0 0 - 633 - 0 4 0 5
Prices as of April 27, 2016. Check Web site for most current prices.
Accessories
Accessories
Part Number
Description
FP-2
Fuse puller for fuse dia. 13/32” - 13/16”. Fuse type: 0-60A, 250V;
0-30A, 600V
Multi-pole connection kit to connect new design multiple Class
CC and Midget Class fuse holders together. Kit consists of 6 connectors and 3 handle pins to connect up to 4 fuse holders.
JV-L*
(Not Field Installable)
Pcs/Pkg Price
1
$16.50
$6.50
Note: Will not work with retired design fuse holders shipped before November 1, 2009.
*Roll pin punch or installation tool is required to install handle pins (Tool not sold by Automationdirect.com).
FP2
Handle Pin Dimensions
Diameter = 0.0625 in [1.58 mm]
Length = 0.632 in [16.07 mm]
JV-L
JV-L
Book 3 (14.3)
eCP-218
Circuit Protection
1 - 8 0 0 - 633 - 0 4 0 5
Prices as of April 27, 2016. Check Web site for most current prices.
Cross Reference Guide
Company
Information
Terminal Blocks
Power
Distribution
Blocks
CROSS REFERENCE GUIDE By manufacturers type reference or series number.
Ampere ratings must be added for ordering purposes.
FUSE TYPE
VOLT EDISON
BRUSH/ BUSSMANN MERSEN / GEC/CEFCO LITTELFUSE
DORMAN
GOULD
UL CLASS CURRENT LIMITING FUSES (CSA CLASS)
CC (HRCI-CC)
RK1
RK5
J
T
Time-Delay
600
EDCC
–
LP-CC
ATDR
–
CCMR
Time-Delay
600
HCTR
–
FNQ-R
ATQR
–
KLDR
Fast-Acting
600
HCLR
HCLR
KTK-R
ATMR
CTK-R
KLKR
250
LENRK
–
LPN-RK-SP
A2DR
–
LLNRK
600
LESRK
–
LPS-RK-SP
A6DR
–
LLSRK
250
ECNR
–
FRN-R
TR
–
FLNR
600
Time-Delay Dual Element
Time-Delay Dual Element
ECSR
–
FRS-R
TRS
–
FLSR
Time-Delay Dual Element 600
JDL
–
LPJ
AJT
–
JTD
High-Speed AC Drive
600
JHL
–
DFJ
HSJ
–
–
300
TJN
–
JJN
A3T
–
JLLN
600
TJS
–
JJS
A6T
–
JLLS
Extremely Fast-Acting
Sensor Cables
and Connectors
M12 Junction
Blocks
Panel Interface
Connectors
Wiring Duct
Cable Ties
Wire
600
MCL
MCL
KTK
ATM
CTK
KLK
250
MOL
MOL
BAF/BAN
OTM
–
BLF
500
MEQ
MEQ
FNQ
ATQ
–
FLQ
250
MEN
MEN
FNM
TRM
–
FLM
250/125 ABC
ABC
ABC
GAB
–
314
250/32 AGC
AGC
AGC
GGC
–
312
250
MDA
MDA
MDA
–
–
326
250/32 MDL
MDL
MDL
GDL
–
313
Fast-Acting
250/125 GMA
GMA
GMA
GGM
–
235
Medium Time-Delay
250/125 GMC
GMC
GMC
GSC
–
–
Fast-Acting
250
S500
BDB
GDB
GSB
–
217
Time-Delay
250
S506
BDC
GDC
GDG
–
218
FP-2
–
–
–
Midget
Time-Delay
1/4”x 1-1/4” Ceramic
1/4”x 1-1/4” Glass
1/4”x 1-1/4” Ceramic
1/4”x 1-1/4” Glass
5x20 mm Glass
5x20 mm Glass
Fast-Acting
Time-Delay
Bulk
Multi-conductor
Cables
Wire
Management
Products
Power Supplies
DC Converters
Transformers
and Filters
Circuit Protection
Tools
Fuse Puller
Fuse Puller FP-2
–
old - 38072 –
new - FP-2
ZIPLink
Connection
System
Multi-wire
Connectors
UL CLASS GENERAL PURPOSE FUSES
Fast-Acting
Wiring
Accessories
Test
Equipment
Enclosures
Enclosure
Climate Control
Safety: Electrical
Components
Safety: Protective
Wear
Terms and
Conditions
Book 3 (14.3)
w w w. a u t o m a t i o n d i r e c t . c o m / c i r c u i t- p r o t e c t i o n
Circuit Protection
eCP-219
Download