GE Lighting GE Protected Metal Halide Lamps Suitable for use in Open Luminaires and are marked with the /O Luminaire Code as specified in ANSI C78.380, High-intensity Discharge Lamps, Method of Designation. Available in Ceramic Metal Halide, MXR and MPR Designed to meet the containment test specified in ANSI C78.389 EX39 Base E39 Base The EX39 base has an extended center terminal that can reach the center contact of an EX39 socket. Standard E39 mogul base Intended primarily for use in open luminaires but may also be operated in enclosed luminaires. MPR lamps employ a quartz shroud that surrounds the arc tube to reduce the potential risk to persons and property in the unlikely case of an arc tube rupture. GE’s protected Ceramic Metal Halide and Quartz MPR lamps are equipped with an EX39 exclusionary base: GE’s EX39 based lamps are fully compatible for new and renovated Metal Halide installations that fall under the jurisdiction of the 2005 and later National Electric Code (NEC) For more information on the 2005 NEC requirements and implications for certain metal halide lamps refer to the guidelines in NEMA LSD25 and NEMA LSD31. EX39 Socket Additional ceramic material around the center contact keeps standard E39 mogul base from seating and making contact ED17 Med BD17 Med Open-rated ED17 lamps have a max. bulb neck diameter of 31.5mm (~1.24”) Enclosed-rated BD17 lamps have a min. bulb neck diam. of 31mm (~ 1.34”) GE MXR protected metal halide lamps employ E26 medium bases: GE’s MXR protected lamps are designed with a narrow neck ED17 bulb that have a maximum neck diameter of 31.5mm (~1.24”) and can be distinguished from GE’s enclosed-rated MXR lamps which uses a BD17 bulb that have a minimum neck diameter of 34mm (~1.34”). GE’s MXR protected MH lamps are in compliance with ANSI standard C78.43 for single-ended MH lamps. g imagination at work EX26 Socket Additional / extended insulator height on “exclusionary” socket keeps BD17 lamp from seating GE Protected Metal Halide Lamps Protected Multi-Vapor® Metal Halide Watts 32 32 50 50 70 70 100 100 150 150 175 175 175 250 250 250 320 320 320 350 350 350 360 360 400 400 400 400 1000 GE Order Code Description ANSI Type 12651 16469 45670 45671 12377 12577 12381 12579 45683 45688 49470 11649 61325 49471 11650 61326 46275 46276 19609 10202 48824 48825 40056 11685 18708 13582 46273 46274 41433 MXR32/C/VBD/O MXR32/C/VBU/O MXR50/U/MED/O MXR50/C/U/MED/O MXR70/U/MED/O MXR70/C/U/MED/O MXR100/U/MED/O MXR100/C/U/MED/O MXR150/U/MED/O MXR150/C/U/MED/O MPR175/VBU/O MPR175/C/VBU/O MPR175/VBU/PA/O MPR250/VBU/O MPR250/C/VBU/O MPR250/VBU/PA/O MPR320/VBU/XHO/PA MPR320/C/VBU/XHO/PA MPR320/C/PA/ED28 MPR350/VBU/PA MPR350/C/VBU/PA MPR350/C/VBU/3K/PA MPR360/VBU/WM/HO/O MPR360/C/VBU/WM/HO/O MPR400/VBU/HO/O MPR400/C/VBU/HO/O MPR400/VBU/XHO/PA MPR400/C/VBU/XHO/PA MPR1000/VBU/O M100 M100 M110 M110 M98 M98 M90 M90 M102 M102 M57 M57 M137 M58 M58 M138 M132 or M154 M132 or M154 M132 or M154 M131 M131 M131 M59 M59 M59 M59 M135 or M155 M135 or M155 M47 Bulb Shape Bulb Size Base Type Finish LET OP Rated Life Lumens Initial Lumens Mean CCT CRI ED ED ED ED ED ED ED ED ED ED BT BT ED BT BT ED ED ED ED ED ED ED ED ED ED ED ED ED BT 17 17 17 17 17 17 17 17 17 17 28 28 28 28 28 28 37 37 28 37 37 37 37 37 37 37 37 37 56 Med Med Med Med Med Med Med Med Med Med EX39 EX39 EX39 EX39 EX39 EX39 EX39 EX39 EX39 EX39 EX39 EX39 EX39 EX39 EX39 EX39 EX39 EX39 EX39 Coated Coated Clear Coated Clear Coated Clear Coated Clear Coated Clear Coated Clear Clear Coated Clear Clear Coated Coated Clear Coated Coated Clear Coated Clear Coated Clear Coated Clear O O O O O O O O O O O O O O O O O O O O O O O O O O O O O VBD VBU U U U U U U U U VBU VBU VBU VBU VBU VBU VBU VBU VBU VBU VBU VBU VBU VBU VBU VBU VBU VBU VBU 10000 10000 10000 10000 12000 12000 15000 15000 15000 15000 10000 10000 15000 10000 10000 15000 20000 20000 20000 20000 20000 20000 20000 20000 20000 20000 20000 20000 12000 2400 2400 3400 3200 5500 5300 9000 8500 12500 12000 15700 14300 16000 21300 19500 23000 32000 30500 30600 35200 33400 33400 36000 35000 40000 38000 42000 40000 110000 1700 1700 1700 1500 3500 3300 6200 5900 8600 8300 8400 7700 11000 14200 12900 16600 22500 21500 24500 24600 26500 23500 23500 22500 26000 25000 29500 28000 88500 3200 3200 3500 3500 3200 3200 3200 3200 3500 3500 4000 3800 3900 4000 3800 3800 4000 3700 3700 3700 3700 3200 4000 3700 3400 3200 4000 3700 3500 70 70 70 70 70 70 70 70 70 70 65 70 65 65 70 75 65 70 70 65 70 70 65 70 65 70 65 70 65 17 17 17 17 17 17 17 17 28 28 37 37 37 37 37 37 37 Med Med Med Med Med Med Med Med EX39 EX39 EX39 EX39 EX39 EX39 EX39 EX39 EX39 Clear Coated Clear Coated Clear Coated Clear Coated Clear Coated Clear Coated Clear Coated Coated Clear Coated O O O O O O O O O O O O O O O O O U U U U U U U U V V V V V V V V V 15000 15000 15000 15000 12000 12000 15000 15000 20000 20000 20000 20000 20000 20000 20000 20000 20000 5700 5700 5500 5200 12900 11900 12000 11000 23000 22000 37000 36000 34000 33000 39000 31000 30000 4100 4100 4200 4000 9500 8800 9000 8300 18400 17600 29600 28800 27200 26400 31200 24800 24000 3000 3000 4000 4000 3000 3000 4200 4200 4100 4100 4200 4200 3600 3600 3700 4100 4100 80 80 90 90 80 80 90 90 90 90 90 90 90 90 92 90 90 Protected ConstantColor® Ceramic Metal Halide (CMH®) 70 70 70 70 150 150 150 150 250 250 320 320 350 350 400 400 400 31069 31070 31073 31074 31065 31066 31067 31068 48429 48432 17264 17267 20035 20036 49911 17259 17260 CMH70/U/830/MED/O CMH70/C/U/830/MED/O CMH70/U/942/MED/O CMH70/C/U/942/MED/O CMH150/U/830/MED/O CMH150/C/U830/MED/O CMH150/U/942/MED/O CMH150/C/U/942/MED/O CMH250//V/PA/O CMH250/C/V/PA/O CMH320/V/PA/O CMH320/C/V/PA/O CMH350/V/PA/O CMH350/C/V/PA/O CMH400/C/VBU/940/PA/O CMH400/V/PA/O CMH400/C/V/PA/O C98 or M143 C98 or M143 C98 or M143 C98 or M143 C102 or C142 C102 or C142 C102 or C142 C102 or C142 ED ED ED ED ED ED ED ED ED ED ED ED ED ED ED ED ED Protected ConstantColor® Ceramic Metal Halide PAR Lamps (CMH® PAR) and Ceramic Metal Halide MR16 Lamps Watts 20 20 20 20 20 20 20 20 23 23 23 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 70 70 70 70 70 100 100 100 GE Order Code Description ANSI Type 85101 85110 97638 29485 29486 29487 29488 29489 76224 76225 76226 71488 71489 71490 71491 71492 71493 42069 42068 96526 96527 45066 42066 42067 96528 96529 96530 22152 22159 45675 45677 45679 45680 45681 45682 CMH20MR16/830/SP CMH20MR16/830/FL CMH20MR16/830/WFL CMH20PAR20/SP CMH20PAR20/FL CMH20PAR30L/SP10 CMH20PAR30L/SP15 CMH20PAR30L/FL25 CMHi23P38SP/ECO CMHi23P38FL/ECO CMHi23P38WFL/ECO CMH39MR16/930/SP CMH39MR16/930/FL CMH39MR16/930WFL CMH39MR16/952/SP CMH39MR16/942/FL CMH30MR16/942WFL CMH39/UPAR20/SP10 CMH39/UPAR20/FL25 CMH39/PAR20/NSP4K CMH39/PAR20/FL4K CMH39/PAR30L/SP10 CMH39/PAR30L/SP15 CMH39/PAR30L/FL25 CMH39/PAR30L/NSP4K CMH39/PAR30L/SP4K CMH39/PAR30L/FL4k CMH70/PAR30L/830/SP CMH70/PAR30L/830/FL CMH70/PAR38/830/SP15/ECO CMH70/PAR38/830/FL25/ECO CMH70/PAR38/830/WFL/ECO CMH100/PAR38/830/SP15/ECO CMH100/PAR38/830/FL25/ECO CMH100/PAR38/830/WFL/ECO C156/M156 C156/M156 C156/M156 M156 M156 M156 M156 M156 C130/M130 C130/M130 C130/M130 C130/M130 C130/M130 C130/M130 C130/M130 C130/M130 C130/M130 C130/M130 C130/M130 C130/M130 C130/M130 C130/M130 C130/M130 C130/M130 M98 or M139 M98 or M139 M98 or M139 M98 or M139 M98 or M139 M90 or M140 M90 or M140 M90 or M140 ! WARNING Risk of electric shock - Turn power off before inspection, installation or removal - Do not use where directly exposed to water or outdoors without an enclosed fixture Risk of fire - Keep combustible materials away from lamp - Use in fixture rated for this product A damaged lamp emits UV radiation which may cause eye/skin injury - Turn power off if glass bulb is broken. Remove and dispose of lamp. Unexpected lamp rupture may cause injury, fire, or property damage - Turn lamp off at least once for 15 minutes per week - Do not use beyond rated life. Beyond rated life, light output diminishes while energy consumption increases. - Do not use lamp if outer glass is scratched or broken - Do not use where directly exposed to water or outdoors without an enclosed fixture - Use in fixture rated for this product -- See Instructions - Do not store flammable materials near/below lamp - Use only properly rated ballast - Do not exceed rated voltage - Do not turn on lamp until fully installed - Operate lamp only in specified position - If used on a dimming system, see instructions. © 2013 GE 81636 1/2013 Printed in USA Bulb Shape Bulb Size Base Type LET OP Rated Life Lumens Initial CBCP CCT CRI MR MR MR PAR PAR PAR PAR PAR PAR PAR PAR MR MR MR MR MR MR PAR PAR PAR PAR PAR PAR PAR PAR PAR PAR PAR PAR PAR PAR PAR PAR PAR PAR 16 16 16 20 20 30L 30L 30L 38 38 38 16 16 16 16 16 16 20 20 20 29 30L 30L 30L 30L 30L 30L 30L 30L 38 38 38 38 38 38 GX10 GX10 GX10 Med Med Med Med Med Med Med Med GX10 GX10 GX10 GX10 GX10 GX10 Med Med Med Med Med Med Med Med Med Med Med Med Med Med Med Med Med Med O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O U U U U U U U U U U U U U U U U U U U U U U U U U U U U U U U U U U U 12000 12000 12000 7500 7500 7500 7500 7500 12000 12000 12000 10000 10000 10000 12000 12000 12000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 13000 13000 10000 10000 10000 10000 10000 10000 1000 1000 1000 1000 1000 1200 1200 1200 1400 1400 1400 2700 2200 2200 2200 2200 2200 2100 2100 1950 1950 2400 2400 2400 2225 2225 2225 4700 4700 4800 4800 4800 6500 6500 6500 9000 2900 1500 13000 3750 19800 14500 4900 28000 6000 2800 16000 5500 3000 16000 5500 3000 22000 7500 19450 6950 39600 29000 11000 36700 26900 10200 43000 10000 40000 14000 4400 45000 15000 5500 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 4000 4000 4000 3000 3000 4200 4200 3000 3000 3000 4200 4200 4200 3000 3000 3000 3000 3000 3000 3000 3000 81 81 81 81 81 81 81 81 81 81 81 90 90 90 92 92 92 86 86 90 90 81 81 81 89 89 89 82 82 82 82 82 81 81 81 ! WARNING R WARNING: This lamp can cause serious skin burn and eye inflammation from shortwave ultraviolet radiation if outer envelope of the lamp is broken or punctured. Do not use where people will remain for more than a few minutes unless adequate shielding or other safety precautions are used. Lamps that will automatically extinguish when the outer envelope is broken or punctured are commercially available. This lamp certified to comply with FDA radiation performance standards, 21 CFR Subchapter J. USA: 21 CFR 1040.30 Canada: SOR/80-381 Arc tube fill gas contains Kr-85 OPERATING INSTRUCTIONS: LAMP OPERATING CHARACTERISTICS This is a discharge lamp and requires some time to restart and come to full brightness after a power interruption. Relamp fixtures at or before the end of rated life. Beyond rated life, light output diminishes while energy consumption increases. SPECIFIED OPERATING POSITION VBU - Base up ± 15º VBD - Base down ± 15º U - Universal Match ANSI code of lamp to code on ballast or luminaire. Electrically insulate any metal to bulb support in luminaire to avoid decomposition of glass. Use in luminaire which comply with UL1598 or IEC 60598. Lamps are suitable for open or enclosed fixtures. For total load, add auxiliary watts to lamp watts. FOR USE ON DIMMING SYSTEMS Most vertical operating lamps are suitable for dimming. Contact your local GE Lighting sales representative. Information provided is subject to change without notice. Please verify all details with GE. All values are design or typical values when measured under laboratory conditions, and GE makes no warranty or guarantee, express or implied, that such performance will be obtained under end-use conditions. For additional product and application information, please consult GE’s Website: www.gelighting.com