GE HID Lighting | GE Protected Metal Halide Lamps | GE Lighting

advertisement
GE
Lighting
GE Protected
Metal Halide Lamps
Suitable for use in Open Luminaires and are
marked with the /O Luminaire Code as specified
in ANSI C78.380, High-intensity Discharge Lamps,
Method of Designation.
Available in Ceramic Metal Halide, MXR and MPR
Designed to meet the containment test specified in
ANSI C78.389
EX39 Base
E39 Base
The EX39 base has an extended center terminal that
can reach the center contact of an EX39 socket.
Standard E39
mogul base
Intended primarily for use in open luminaires
but may also be operated in enclosed luminaires.
MPR lamps employ a quartz shroud that surrounds
the arc tube to reduce the potential risk to persons
and property in the unlikely case of an arc tube rupture.
GE’s protected Ceramic Metal Halide and Quartz MPR lamps
are equipped with an EX39 exclusionary base:
GE’s EX39 based lamps are fully compatible for new and
renovated Metal Halide installations that fall under the
jurisdiction of the 2005 and later National Electric Code (NEC)
For more information on the 2005 NEC requirements and
implications for certain metal halide lamps refer to the
guidelines in NEMA LSD25 and NEMA LSD31.
EX39 Socket
Additional ceramic material around the
center contact keeps standard E39 mogul base
from seating and making contact
ED17 Med
BD17 Med
Open-rated ED17
lamps have a max.
bulb neck diameter of
31.5mm (~1.24”)
Enclosed-rated BD17
lamps have a min. bulb
neck diam. of 31mm
(~ 1.34”)
GE MXR protected metal halide lamps employ E26 medium bases:
GE’s MXR protected lamps are designed with a narrow neck
ED17 bulb that have a maximum neck diameter of 31.5mm
(~1.24”) and can be distinguished from GE’s enclosed-rated
MXR lamps which uses a BD17 bulb that have a minimum
neck diameter of 34mm (~1.34”). GE’s MXR protected
MH lamps are in compliance with ANSI standard
C78.43 for single-ended MH lamps.
g
imagination at work
EX26 Socket
Additional / extended insulator
height on “exclusionary” socket
keeps BD17 lamp from seating
GE Protected Metal Halide Lamps
Protected Multi-Vapor® Metal Halide
Watts
32
32
50
50
70
70
100
100
150
150
175
175
175
250
250
250
320
320
320
350
350
350
360
360
400
400
400
400
1000
GE Order
Code
Description
ANSI
Type
12651
16469
45670
45671
12377
12577
12381
12579
45683
45688
49470
11649
61325
49471
11650
61326
46275
46276
19609
10202
48824
48825
40056
11685
18708
13582
46273
46274
41433
MXR32/C/VBD/O
MXR32/C/VBU/O
MXR50/U/MED/O
MXR50/C/U/MED/O
MXR70/U/MED/O
MXR70/C/U/MED/O
MXR100/U/MED/O
MXR100/C/U/MED/O
MXR150/U/MED/O
MXR150/C/U/MED/O
MPR175/VBU/O
MPR175/C/VBU/O
MPR175/VBU/PA/O
MPR250/VBU/O
MPR250/C/VBU/O
MPR250/VBU/PA/O
MPR320/VBU/XHO/PA
MPR320/C/VBU/XHO/PA
MPR320/C/PA/ED28
MPR350/VBU/PA
MPR350/C/VBU/PA
MPR350/C/VBU/3K/PA
MPR360/VBU/WM/HO/O
MPR360/C/VBU/WM/HO/O
MPR400/VBU/HO/O
MPR400/C/VBU/HO/O
MPR400/VBU/XHO/PA
MPR400/C/VBU/XHO/PA
MPR1000/VBU/O
M100
M100
M110
M110
M98
M98
M90
M90
M102
M102
M57
M57
M137
M58
M58
M138
M132 or M154
M132 or M154
M132 or M154
M131
M131
M131
M59
M59
M59
M59
M135 or M155
M135 or M155
M47
Bulb
Shape
Bulb
Size
Base
Type
Finish
LET
OP
Rated
Life
Lumens
Initial
Lumens
Mean
CCT
CRI
ED
ED
ED
ED
ED
ED
ED
ED
ED
ED
BT
BT
ED
BT
BT
ED
ED
ED
ED
ED
ED
ED
ED
ED
ED
ED
ED
ED
BT
17
17
17
17
17
17
17
17
17
17
28
28
28
28
28
28
37
37
28
37
37
37
37
37
37
37
37
37
56
Med
Med
Med
Med
Med
Med
Med
Med
Med
Med
EX39
EX39
EX39
EX39
EX39
EX39
EX39
EX39
EX39
EX39
EX39
EX39
EX39
EX39
EX39
EX39
EX39
EX39
EX39
Coated
Coated
Clear
Coated
Clear
Coated
Clear
Coated
Clear
Coated
Clear
Coated
Clear
Clear
Coated
Clear
Clear
Coated
Coated
Clear
Coated
Coated
Clear
Coated
Clear
Coated
Clear
Coated
Clear
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
VBD
VBU
U
U
U
U
U
U
U
U
VBU
VBU
VBU
VBU
VBU
VBU
VBU
VBU
VBU
VBU
VBU
VBU
VBU
VBU
VBU
VBU
VBU
VBU
VBU
10000
10000
10000
10000
12000
12000
15000
15000
15000
15000
10000
10000
15000
10000
10000
15000
20000
20000
20000
20000
20000
20000
20000
20000
20000
20000
20000
20000
12000
2400
2400
3400
3200
5500
5300
9000
8500
12500
12000
15700
14300
16000
21300
19500
23000
32000
30500
30600
35200
33400
33400
36000
35000
40000
38000
42000
40000
110000
1700
1700
1700
1500
3500
3300
6200
5900
8600
8300
8400
7700
11000
14200
12900
16600
22500
21500
24500
24600
26500
23500
23500
22500
26000
25000
29500
28000
88500
3200
3200
3500
3500
3200
3200
3200
3200
3500
3500
4000
3800
3900
4000
3800
3800
4000
3700
3700
3700
3700
3200
4000
3700
3400
3200
4000
3700
3500
70
70
70
70
70
70
70
70
70
70
65
70
65
65
70
75
65
70
70
65
70
70
65
70
65
70
65
70
65
17
17
17
17
17
17
17
17
28
28
37
37
37
37
37
37
37
Med
Med
Med
Med
Med
Med
Med
Med
EX39
EX39
EX39
EX39
EX39
EX39
EX39
EX39
EX39
Clear
Coated
Clear
Coated
Clear
Coated
Clear
Coated
Clear
Coated
Clear
Coated
Clear
Coated
Coated
Clear
Coated
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
U
U
U
U
U
U
U
U
V
V
V
V
V
V
V
V
V
15000
15000
15000
15000
12000
12000
15000
15000
20000
20000
20000
20000
20000
20000
20000
20000
20000
5700
5700
5500
5200
12900
11900
12000
11000
23000
22000
37000
36000
34000
33000
39000
31000
30000
4100
4100
4200
4000
9500
8800
9000
8300
18400
17600
29600
28800
27200
26400
31200
24800
24000
3000
3000
4000
4000
3000
3000
4200
4200
4100
4100
4200
4200
3600
3600
3700
4100
4100
80
80
90
90
80
80
90
90
90
90
90
90
90
90
92
90
90
Protected ConstantColor® Ceramic Metal Halide (CMH®)
70
70
70
70
150
150
150
150
250
250
320
320
350
350
400
400
400
31069
31070
31073
31074
31065
31066
31067
31068
48429
48432
17264
17267
20035
20036
49911
17259
17260
CMH70/U/830/MED/O
CMH70/C/U/830/MED/O
CMH70/U/942/MED/O
CMH70/C/U/942/MED/O
CMH150/U/830/MED/O
CMH150/C/U830/MED/O
CMH150/U/942/MED/O
CMH150/C/U/942/MED/O
CMH250//V/PA/O
CMH250/C/V/PA/O
CMH320/V/PA/O
CMH320/C/V/PA/O
CMH350/V/PA/O
CMH350/C/V/PA/O
CMH400/C/VBU/940/PA/O
CMH400/V/PA/O
CMH400/C/V/PA/O
C98 or M143
C98 or M143
C98 or M143
C98 or M143
C102 or C142
C102 or C142
C102 or C142
C102 or C142
ED
ED
ED
ED
ED
ED
ED
ED
ED
ED
ED
ED
ED
ED
ED
ED
ED
Protected ConstantColor® Ceramic Metal Halide PAR Lamps (CMH® PAR) and Ceramic Metal Halide MR16 Lamps
Watts
20
20
20
20
20
20
20
20
23
23
23
39
39
39
39
39
39
39
39
39
39
39
39
39
39
39
39
70
70
70
70
70
100
100
100
GE Order
Code
Description
ANSI
Type
85101
85110
97638
29485
29486
29487
29488
29489
76224
76225
76226
71488
71489
71490
71491
71492
71493
42069
42068
96526
96527
45066
42066
42067
96528
96529
96530
22152
22159
45675
45677
45679
45680
45681
45682
CMH20MR16/830/SP
CMH20MR16/830/FL
CMH20MR16/830/WFL
CMH20PAR20/SP
CMH20PAR20/FL
CMH20PAR30L/SP10
CMH20PAR30L/SP15
CMH20PAR30L/FL25
CMHi23P38SP/ECO
CMHi23P38FL/ECO
CMHi23P38WFL/ECO
CMH39MR16/930/SP
CMH39MR16/930/FL
CMH39MR16/930WFL
CMH39MR16/952/SP
CMH39MR16/942/FL
CMH30MR16/942WFL
CMH39/UPAR20/SP10
CMH39/UPAR20/FL25
CMH39/PAR20/NSP4K
CMH39/PAR20/FL4K
CMH39/PAR30L/SP10
CMH39/PAR30L/SP15
CMH39/PAR30L/FL25
CMH39/PAR30L/NSP4K
CMH39/PAR30L/SP4K
CMH39/PAR30L/FL4k
CMH70/PAR30L/830/SP
CMH70/PAR30L/830/FL
CMH70/PAR38/830/SP15/ECO
CMH70/PAR38/830/FL25/ECO
CMH70/PAR38/830/WFL/ECO
CMH100/PAR38/830/SP15/ECO
CMH100/PAR38/830/FL25/ECO
CMH100/PAR38/830/WFL/ECO
C156/M156
C156/M156
C156/M156
M156
M156
M156
M156
M156
C130/M130
C130/M130
C130/M130
C130/M130
C130/M130
C130/M130
C130/M130
C130/M130
C130/M130
C130/M130
C130/M130
C130/M130
C130/M130
C130/M130
C130/M130
C130/M130
M98 or M139
M98 or M139
M98 or M139
M98 or M139
M98 or M139
M90 or M140
M90 or M140
M90 or M140
! WARNING
Risk of electric shock
- Turn power off before inspection, installation or removal
- Do not use where directly exposed to water or outdoors
without an enclosed fixture
Risk of fire
- Keep combustible materials away from lamp
- Use in fixture rated for this product
A damaged lamp emits UV radiation which may cause eye/skin injury
- Turn power off if glass bulb is broken. Remove and dispose of lamp.
Unexpected lamp rupture may cause injury, fire, or property damage
- Turn lamp off at least once for 15 minutes per week
- Do not use beyond rated life. Beyond rated life, light output diminishes
while energy consumption increases.
- Do not use lamp if outer glass is scratched or broken
- Do not use where directly exposed to water or outdoors
without an enclosed fixture
- Use in fixture rated for this product -- See Instructions
- Do not store flammable materials near/below lamp
- Use only properly rated ballast
- Do not exceed rated voltage
- Do not turn on lamp until fully installed
- Operate lamp only in specified position
- If used on a dimming system, see instructions.
© 2013 GE
81636
1/2013
Printed in USA
Bulb
Shape
Bulb
Size
Base
Type
LET
OP
Rated
Life
Lumens
Initial
CBCP
CCT
CRI
MR
MR
MR
PAR
PAR
PAR
PAR
PAR
PAR
PAR
PAR
MR
MR
MR
MR
MR
MR
PAR
PAR
PAR
PAR
PAR
PAR
PAR
PAR
PAR
PAR
PAR
PAR
PAR
PAR
PAR
PAR
PAR
PAR
16
16
16
20
20
30L
30L
30L
38
38
38
16
16
16
16
16
16
20
20
20
29
30L
30L
30L
30L
30L
30L
30L
30L
38
38
38
38
38
38
GX10
GX10
GX10
Med
Med
Med
Med
Med
Med
Med
Med
GX10
GX10
GX10
GX10
GX10
GX10
Med
Med
Med
Med
Med
Med
Med
Med
Med
Med
Med
Med
Med
Med
Med
Med
Med
Med
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
12000
12000
12000
7500
7500
7500
7500
7500
12000
12000
12000
10000
10000
10000
12000
12000
12000
10000
10000
10000
10000
10000
10000
10000
10000
10000
10000
13000
13000
10000
10000
10000
10000
10000
10000
1000
1000
1000
1000
1000
1200
1200
1200
1400
1400
1400
2700
2200
2200
2200
2200
2200
2100
2100
1950
1950
2400
2400
2400
2225
2225
2225
4700
4700
4800
4800
4800
6500
6500
6500
9000
2900
1500
13000
3750
19800
14500
4900
28000
6000
2800
16000
5500
3000
16000
5500
3000
22000
7500
19450
6950
39600
29000
11000
36700
26900
10200
43000
10000
40000
14000
4400
45000
15000
5500
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
4000
4000
4000
3000
3000
4200
4200
3000
3000
3000
4200
4200
4200
3000
3000
3000
3000
3000
3000
3000
3000
81
81
81
81
81
81
81
81
81
81
81
90
90
90
92
92
92
86
86
90
90
81
81
81
89
89
89
82
82
82
82
82
81
81
81
! WARNING
R WARNING:
This lamp can cause serious
skin burn and eye inflammation
from shortwave ultraviolet
radiation if outer envelope of
the lamp is broken or punctured.
Do not use where people will
remain for more than a few
minutes unless adequate
shielding or other safety
precautions are used. Lamps
that will automatically extinguish
when the outer envelope is
broken or punctured are
commercially available.
This lamp certified to comply
with FDA radiation performance
standards, 21 CFR Subchapter J.
USA: 21 CFR 1040.30 Canada:
SOR/80-381
Arc tube fill gas contains Kr-85
OPERATING INSTRUCTIONS:
LAMP OPERATING CHARACTERISTICS
This is a discharge lamp and requires some time to restart and come to full brightness
after a power interruption.
Relamp fixtures at or before the end of rated life. Beyond rated life, light output diminishes
while energy consumption increases.
SPECIFIED OPERATING POSITION
VBU - Base up ± 15º
VBD - Base down ± 15º
U - Universal
Match ANSI code of lamp to code on ballast or luminaire.
Electrically insulate any metal to bulb support in luminaire to avoid decomposition of glass.
Use in luminaire which comply with UL1598 or IEC 60598. Lamps are suitable for open or
enclosed fixtures.
For total load, add auxiliary watts to lamp watts.
FOR USE ON DIMMING SYSTEMS
Most vertical operating lamps are suitable for dimming. Contact your local GE Lighting
sales representative.
Information provided is subject to change without notice. Please verify all details with GE. All values are