Installation Instructions Blocked Vent Safety Switch for use by heating contractor for Vitorond 100, VR1 (oil fired) boilers Part Number: 7134540, 7134541 Safety and Installation Requirements Please ensure that these instructions are read and understood before starting any service work. Failure to comply with these instructions may cause product/property damage, severe personal injury and/or loss of life. Ensure that main power to the equipment being serviced is off. Working on the equipment The installation, adjustment, service and maintenance of this product must be performed by a licensed professional heating contractor who is qualified and experienced in the installation, service, and maintenance of hot water boilers. There are no user serviceable parts on the boiler, burner or control. Take precautions to avoid accidental activation of power or fuel during service work. Ensure that the main fuel supply valve to the boiler is closed. Do not perform service work on any component part without ensuring safe operation of the heating system. When replacing parts, use original Viessmann or Viessmann approved replacement parts. Refer to the Installation and Service Instructions applicable to this boiler. Product Information CAUTION For use with chimney venting only. Do not use in conjunction with any approved sidewall power venting or direct vent application. These venting systems will provide a safety shutdown in case the vent system becomes blocked. Installation of a secondary safety switch is required for oil-fired installations not equipped with a draft hood. This device is designed to detect flue gas spillage from a blocked flue system and/or inadequate draft. For proper placement of blocked vent safety switch see illustrations below. IMPORTANT There may be additional parts supplied in this kit. Refer to appropriate page for specific instructions on burner/boiler combination. Refer to the Installation and Service Instructions applicable to this boiler. Recommended placement of safety switch 5285 847 - 01 06/2014 Not recommended Installation & Wiring Blocked Vent Safety Switch Installation (Vitorond 100 with Beckett (NX, AFG) burner and Honeywell Aquastat, Part No. 7134 540) 1. Disconnect the orange wire of oil primary control of the burner from the burner motor. 2. Install blocked vent switch (see enclosed Field Controls WMO-1 Installation Instructions). 3. Run BX cable (armored cable) or any other approved wire (required by local authority having jurisdiction) from switch to burner junction box. 2 5285 847 - 01 4. Rewire the burner motor through safety switch and back to orange wire of oil burner primary control (see page 3). Blocked Vent Safety Switch Installation Installation & Wiring (Beckett burner with GeniSys primary control and Hydrostat) WARNING Electric shock hazard. Can cause severe personal injury or loss of life if power source, including service switch on boiler, is not disconnected before installing or servicing. Installations must follow these codes and requirements: - National Electrical Code (N.E.C.), ANSI/NFPA 70, latest edition and any additional national, state or local codes. - In Canada, CSA C22.1 Canadian Electrical Code Part 1 and any local codes. - CSA B-139 installation code for oil boilers. - Wiring must be N.E.C. Class 1. If original wire as supplied with boiler must be replaced, type 105°C wire or equivalent must be used. Supply wiring to boiler and additional control wiring must be 14 ga. or heavier. - Provide electrical ground at boiler as required by codes. H All field supplied nominal 120 VAC voltage wiring must be sheathed in a flexible metal conduit. Hydrostat Legend A Power supply, provide disconnect means and overload protection as required. B Control case must be connected to earth ground. Use grounding provided. C B1 is a in. tab terminal. D Circulator E Temperature limit control (when required by local jurisdiction) CAUTION A field supplied manual reset high limit control must be installed at the outlet pipe of the boiler to interrupt burner operation should the factory supplied high limit control fail. This field supplied high limit control must be set 20° F (7° C) above the setting of the factory supplied high limit control. The setting of this field supplied high limit control must never be greater than 220°F (104° C). IMPORTANT 5285 847 - 01 If burner lock-out occurs, verify blocked vent safety switch operation first. 3 Installation & Wiring Blocked Vent Safety Switch Installation (Vitorond 100 with Riello burner and Hydrostat) IMPORTANT CAUTION There are additional parts supplied in this kit. Refer to appropriate page for specific instructions on burner/boiler combination. For use with chimney venting only. Do not use in conjunction with sidewall power venting or direct vent application. These venting systems will provide a safety shutdown in case the vent system becomes blocked. Hydrostat 4 5285 847 - 01 Legend A Power supply, provide disconnect means and overload protection as required. B Control case must be connected to earth ground. Use grounding provided. C B1 is a in. tab terminal. D Circulator Blocked Vent Safety Switch Installation Burner Set-up WARNING Electric shock hazard. Can cause severe personal injury or loss of life if power source, including service switch on boiler, is not disconnected before installing or servicing. Electrical connections (with Vitotronic control) Installations must follow these codes and requirements: - National Electrical Code (N.E.C.), ANSI/NFPA 70, latest edition and any additional national, state or local codes. - In Canada, CSA C22.1 Canadian Electrical Code Part 1 and any local codes. - CSA B-139 installation code for oil boilers. - Wiring must be N.E.C. Class 1. If original wire as supplied with boiler must be replaced, type 105°C wire or equivalent must be used. Supply wiring to boiler and additional control wiring must be 14 ga. or heavier. - Provide electrical ground at boiler as required by codes. Burner wiring harness (supplied) Closed end connectors are factory installed on RED, ORANGE and BLUE wires. These RED, ORANGE and BLUE wires may or may not be used in your burner application. See wiring diagram in this manual which is specific to your burner application. Do not remove or cut any of the closed end connectors of the RED, ORANGE or BLUE wires, unless it is necessary to do so. RED wire is live (120VAC) at all times. Do not remove or cut its closed end connector unless it is necessary to do so. Failure to heed the above instructions may cause severe personal injury or loss of life. Burner wiring harness (supplied) 5285 847 - 01 Legend BL OR BK WT GN RD Blue Orange Black White Green / Ground Red * If Beckett burner is being installed, cut this length to 6” for connection to burner junction box (located under the burner primary control). 5 Burner Set-up Blocked Vent Safety Switch Installation (Beckett burner with GeniSys primary control and Vitotronic control) WARNING Electric shock hazard. Can cause severe personal injury or loss of life if power source, including service switch on boiler, is not disconnected before installing or servicing. WARNING Ensure that the burner cycles ON and OFF on proper call for heat before leaving the job site. Failure to do so may lead to boiler runaway situation, which may lead to property damage, personal injury or death. Wiring diagram (Vitorond 100 with Beckett burner, GeniSys control and Vitotronic control) Installations must follow these codes and requirements: - National Electrical Code (N.E.C.), ANSI/NFPA 70, latest edition and any additional national, state or local codes. - In Canada, CSA C22.1 Canadian Electrical Code Part 1 and any local codes. - CSA B-139 installation code for oil boilers. - Wiring must be N.E.C. Class 1. If original wire as supplied with boiler must be replaced, type 105°C wire or equivalent must be used. Supply wiring to boiler and additional control wiring must be 14 ga. or heavier. - Provide electrical ground at boiler as required by codes. IMPORTANT 6 5285 847 - 01 If burner lock-out occurs, verify blocked vent safety switch operation first. Blocked Vent Safety Switch Installation Wiring Diagram (Vitorond 100 with Riello burner and Vitotronic control) WARNING Ensure that the burner cycles ON and OFF on proper call for heat before leaving the job site. Failure to do so may lead to boiler runaway situation, which may lead to property damage, personal injury or death. WARNING Electric shock hazard. Can cause severe personal injury or loss of life if power source, including service switch on boiler, is not disconnected before installing or servicing. Installations must follow these codes and requirements: - National Electrical Code (N.E.C.), ANSI/NFPA 70, latest edition and any additional national, state or local codes. - In Canada, CSA C22.1 Canadian Electrical Code Part 1 and any local codes. - CSA B-139 installation code for oil boilers. - Wiring must be N.E.C. Class 1. If original wire as supplied with boiler must be replaced, type 105°C wire or equivalent must be used. Supply wiring to boiler and additional control wiring must be 14 ga. or heavier. - Provide electrical ground at boiler as required by codes. WARNING 5285 847 - 01 RED wire not used in this application. DO NOT cut or remove closed end connector from the wire. (Live 120VAC at all times). 7 5285 847 - 01 Technical information subject to change without notice. Printed on environmentally friendly (recycled and recyclable) paper. Blocked Vent Safety Switch Installation