Radox 125 Connecting leads GENERAL PROPERTIES : Excellent high temperature, low temperature, ozone and weathering resistance, halogen free, soldering iron resistant, easy to strip and process, flexible. APPLICATION : For protected and fixed installation inside electrical equipment, especially suitable for the connection of motor windings, switchboards, magnets and transformers. 2 1 1. Conductor : Stranded tin plated copper, according to IEC 228 cl.5 2. Insulation : RADOX 125 , extruded irradiation crosslinked polyolefin Colours : diverse Printing: HUBER + SUHNER SWITZERLAND RADOX 125 ...mm2 TECHNICAL DATA : Temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -- 40 ... + 125 . . . . . °C TABLE 1 : Dimensions, conductor resistance, weight Cross section nom. Conductor construction nom. Conductor diameter max. Core diameter D R20 IEC 228 max. Weight nom. Nominal voltage Test voltage Min. bending radius mm2 n x mmØ mm mm Ω / km kg / 100m V V mm 0.25 19 x 0.13 0.6 1.45 ± 0.05 85.9 0.4 450/750 2500 3xD 0.34 19 x 0.16 0.8 1.60 ± 0.10 52.1 0.5 450/750 2500 3xD 0.50 19 x 0.18 0.9 1.70 ± 0.10 40.1 0.7 450/750 2500 3xD 0.75 24 x 0.20 1.15 2.20 ± 0.10 26.7 1.1 600/1000 3500 3xD 1.0 32 x 0.20 1.3 2.60 ± 0.10 20.0 1.5 600/1000 3500 3xD 1.5 30 x 0.25 1.55 2.73 ± 0.10 13.7 1.9 600/1000 3500 3xD 2.5 48 x 0.25 2.05 3.50 ± 0.10 8.21 3.0 600/1000 3500 3xD 4.0 56 x 0.30 2.6 4.15 ± 0.15 5.09 4.6 600/1000 3500 3xD 6.0 82 x 0.30 3.4 4.95 ± 0.15 3.39 6.7 600/1000 3500 3xD 10 78 x 0.40 4.4 6.15 ± 0.15 1.95 11 600/1000 3500 3xD 16 119 x 0.40 5.4 7.35 ± 0.15 1.24 16.5 600/1000 3500 3xD 25 182 x 0.40 6.7 8.9 ± 0.2 0.795 25 600/1000 3500 3xD 35 266 x 0.40 7.9 10.3 ± 0.2 0.565 34.9 600/1000 3500 3xD 50 378 x 0.40 9.4 12.1 ± 0.25 0.393 50 600/1000 3500 4xD 70 348 x 0.50 11.5 14.4 ± 0.25 0.277 70.8 600/1000 3500 4xD 95 444 x 0.50 12.9 16.0 ± 0.3 0.210 89 600/1000 3500 4xD 120 570 x 0.50 15.1 18.6 ± 0.3 0.164 116 600/1000 3500 4xD 150 722 x 0.50 17.0 20.5 ± 0.3 0.132 145 600/1000 3500 4xD 185 874 x 0.50 18.5 22.2 ± 0.3 0.108 173 600/1000 3500 4xD 240 1147 x 0.50 21.3 25.4 ± 0.3 0.0817 225 600/1000 3500 4xD Copyright 2010 Huber + Suhner AG. This document may not be copied nor be passed on to third parties without our written permission. Uncontrolled copy when printed (will not be updated]. Wire+Cable Division CH--8330 Pfäffikon +41 (0)44 952 22 11 +41 (0)44 952 26 40 FAX www.hubersuhner.com The product fulfils the test and specification requirements described in this document for the stated areas of application and operating conditions. HUBER+SUHNER AG does not expressly or implicitly guarantee performance under additional or changed conditions. Deviations are to be agreed upon in writing. Issue 06.07.2010 / 2447 Release 2453 Supersedes issue H 08.01.2009 TechnicalDatasheet Page 1/2 559 926 I (e) Radox 125 Connecting leads The cables are in conformity with : Halogen--free compound . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . fulfilled . . . . . . . . . . . . . . . EN 50363 Corrosivity of combustion gases . . . . . . . . . . . . . . . . . . . . . . . . . pH ≥ 4.3, σ ≤ 10 μS/mm EN 50267--2--2 Amount of halogen acid gas . . . . . . . . . . . . . . . . . . . . . . . . . . . . HCI+HBr ≤ 0.5% . . . . . . EN 50267--2--1 Content of fluorine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HF ≤ 0.1% . . . . . . . . . . . EN 60684--2, # 45.2 Issue 06.07.2010 / 2447 Release 2453 Supersedes issue H 08.01.2009 TechnicalDatasheet Page 2/2 559 926 I (e)