The battery is constructed by plates,
separators, safety valves and container.
Since the electrolyte is held by a glassmat separator and plates, the battery
can use in any direction and position
without leakage.
PERFORMANCE SPECIFICATIONS
Nominal Voltage(V)....................................................................................................................6 volts(3cells in series)
Nominal Capacity(AH)
20 hour rate F.V.(1.75V/cell) (150mA to 5.25volts) ...................................................................................3.00A.H.
10 hour rate F.V.(1.75V/cell) (285mA to 5.25volts) ...................................................................................2.85A.H.
5 hour rate F.V.(1.75V/cell) ( 510mA to 5.25volts) ....................................................................................2.55A.H.
1 hour rate F.V.(1.55V/cell) ( 1800mA to 4.65volts)....................................................................................1.80A.H.
Approximate Weight.................................................................................................................................650g(1.43lbs.)
Terminal
Standard..........................................................................................................................................................Type T1
Internal Resistance (Fully Charged Battery).......................................................................................................<30m
Maximum Discharge Current For 5 sec.(A)..............................................................................................................45A
Maximum Charge Current(A)...................................................................................................................................0.9A
Ambient Temperature
Charge.....................................................................................................................................0oC(32oF)~40oC(104oF)
Discharge..............................................................................................................................-20oC(-4oF)~50oC(122oF)
Storage..................................................................................................................................-20oC(-4oF)~40oC(104oF)
Vibration test:
Frequency: 16.7HZ
Amplitude: 4mm
Vibrate the battery horizontally or vertically for 60 minutes.The battery have no abnormality.
Case..........................................................................................................................................................................ABS
Dimension(mm/inch)
Length
1.5mm............................................................................................................................134/5.28
Width
1.5mm..............................................................................................................................34/1.34
Container Height
1.5mm..............................................................................................................................60/2.36
Total Height
2mm.................................................................................................................................66/2.60
Application.................................................................................................................................................Security, UPS.
O
O
BP3-6 Battery discharge characteristics (25 C/77 F)
BATTERY CHARGING CHARACTERISTICS
(Typical example of the charge characteristic for the standby use)
0.51A 0.285A 0.15A
0.75A
5.00
1.8A
4.50
3.50
1
2
3
5
10
6A
120
0.18
7.00
0.15
6.50
80
60
40
4.00
9A
7.50
0.06
0.03
0
0
C ha rg e
6.00
20
30
vo lu m e
1 Discharge
100%(0.05CA 20h)
50%(0.05CA 10h)
2 Constant voltage charging
Charge voltage:2.275V/cell
Charge current:0.1CA
O
O
3 Temperature 20 C(68 F)
5.50
5.00
Charge current
60
2
3
5
10
20
0
0
5
10
30
15
20
25
Charge time (hr)
Hr
Effect of Temperature on Long Term Float Life
10
8
Charging Procedure
Temperature
Charging
compensation
Voltage
coefficient of
at 20OC
voltage
(V/cell) charging
(mV/ OC/cell)
2.25~2.30
-3
Max. charging
current
(CA)
Charging time
O
0.1CA, 20 C
(h)
100%
discharge
0.3
Temp
O
( C)
50%
discharge
24
6
5
4
Life expectancy(year)
Constant
For standby
voltage &
power Source
Constant
current
charging
For
(with current
cycle service restrication)
0.09
20
Discharge time
Charging
method
0.12
Charge voltage
3A
Min
Application
Charge voltage(V)
5.50
0.21
100
Charge volume(%)
Terminal Voltage(V)
6.00
140
Chargeing current(CA)
6.50
20
3
2
1
0~40
O
(32~104 F)
2.40~2.50
-4
0.3
16
Charging voltage :
2.275V/cell
10
0.5
O
20
68
O
*Temperature compensation of charging voltage is not needed, when using the batteries within 5 C to 35 C range.
50 oC
122 oF
40
104
Battery temperature
TERMINAL TYPE
mm(inch)
o
o
Constant power discharge characteristics at 25 C/77 F
Terminal T1
Discharge time
4.75(0.187)
OUTER DIMENSIONS
30
86
Final Voltage
5Min
10Min
15Min
30Min
1Hr
3Hr
5Hr
10Hr
20Hr
Battery output power(W)
6.35(0.25)
34 1.5(1.34 0.06)
5.40V
54.2
39.9
32.0
19.0
10.92
4.37
3.01
1.68
0.88
5.25V
62.8
43.3
33.5
19.8
11.24
4.46
3.06
1.71
0.90
5.10V
66.7
44.8
34.5
20.2
11.45
4.50
3.08
1.72
0.90
4.95V
69.7
45.9
35.3
20.5
11.58
4.53
3.09
1.72
0.91
4.80V
72.0
46.8
36.0
20.7
11.70
4.56
3.10
1.72
0.91
TERMINAL
POSITION
60 1.5(2.36 0.06)
66 2(2.60 0.08)
134 1.5(5.28 0.06)
0.8(0.03)
3.2(0.13)
UL
R
MH19884
B.B. BATTERY CO., LTD.
Web Site: http://www.bb-battery.com
USA :
B&B BATTERY (USA) INC.
6415 RANDOLPH ST. COMMERCE,
CA, 90040 U.S.A.
TEL: 1-323-278-1900 . 1-800-278-8599
FAX: 1-323-278-1268
CHINA FACTORY:
CHENG DONG TRIAL AREA, HUANG GANG,
RAOPING GUANG DONG, CHINA, 515700
TEL: 86-768-7601001-2
FAX: 86-768-7601469
UK:
JAPAN:
B & B BATTERY (UK) CO., LTD.
TEL: 44-161-339-9458
FAX: 44-161-343-7030
B & B BATTERY(JAPAN) CO., LTD.
TEL: 81-426-256-537
FAX: 81-426-256-537
HONG KONG:
TAIWAN:
NATIONAL TRADING LTD.
B & B BATTERY CO., LTD.
TEL: 852-2301-3800
FAX: 852-2739-1182
TEL: 886-6-5898081~3
FAX: 886-6-5898087
QUALITY ASSURED
FIRM
NATIONAL
ACCREDITATION
OF CERTIFICATION
BODIES
I
S
O
1
4
0
0
1
UKAS
ENVIRONMENTAL
MANAGEMENT
Reg. No. 059-C
Download