HP90 Surface Surface 2'X4' Fluorescent; T5 or T5HO Page 1 of 3 2-17/32" (64mm) 2-15/16" (59mm) 24-1/8" (613mm) 7/8" (73mm) Dia. KO (2) 1/4" (51mm) Mounting Holes (2) 3-5/8" (92mm) 24-1/8" (613mm) 39-3/4" (1010mm) 2-15/16" (75mm) 1-5/8" (41mm) 42-1/5" (1080m 48" (1219mm) Ordering Information HP90 Body Style Fixture Width Ceiling Type HD B 2 S Direct/Indirect Surface Fluorescent B = Surface mounted 2 = 24" S = Surface (Nominal Size) Lens Type L L = Acrylic high light transmission linear prismatic lens Features • Direct/indirect appearance with soft contoured interior. • Translucent DR acrylic high light transmission linear prismatic lens. • Lens encloses lamp compartment. • Lamp shield opens from either side. • Ballast accessible from room side. • 87.0% efficient 1 lamp, 28W T5. • 88.5% efficient 2 lamp, 28W T5. • 83.6% efficient 1 lamp, 54W T5HO. • 74.8% efficient 2 lamp, 54W T5HO. • Tension screws secure ends to body. • Optional DALI ballast iGEN TECHNOLOGY accepts digital dimming controllers, scene controllers and automatic control devices. • Not for continuous row mounting. Reflector Lamp Qty. Lamps Voltage (by others) 120 = 120v 277 = 277v UNV = 120-277v Ballast Type Options W W = White 1 = 1 Lamp 2 = 2 Lamps 28 = 28W T5 54 = 54W T5HO (Nominal 48") Job Information Job Name: Cat. No.: Notes: Add appropriate suffix to catalog no., i.e.: (C) <10THD 1 or 2 Lamp Elec. T5/T5HO Program Start 1 or 2 Lamp Elec. T5 Program Start Step-Dim (28 watt only) 120v or 277v only 1 or 2 Lamp Elec. T5 Instant Start (28 watt only, 0.93 ballast factor) 1 or 2 Lamp Elec. T5/T5HO LOL Dimming Type: PG VY WA PF HP90 Surface Surface 2'X4' Fluorescent; T5 or T5HO Page 2 of 3 Specifications Materials: Chassis Parts–Die-formed code gauge cold rolled steel. Labels: I.B.E.W. and cULus. cULus Listed for damp locations. This product may have a mercury containing lamp. Manage in accord with Disposal. Laws. See: www.lamprecycle.org Finish: Chassis exterior–white baked polyester enamel. Cavity—white baked polyester enamel. Rust preventative undercoating. Options & Accessories Electrical Wiring Options: Consult factory. Lens: L–Linear prismatic translucent DR acrylic lens. Low profile integral emergency pack: Suffix: L5 or L6. Reflector: W–Soft white post painted polyester powder. Fusing: Internal fast blow fusing: Suffix: A. Internal slow blow fusing: Suffix: C. Electrical:Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. Performance In an installation of a 1 lamp 54W luminaire in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .83. To reduce glare the average brightness at 65° shall not exceed 1856 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 77.5%. Photometry LER = 60.5 IW = 60.8 BF = 1.0 Comparative yearly lighting energy cost per 1000 lumens = $3.97 Report Number: G2008213A Catalog Number: HDB2SLW154UNVPG Lamps: (1) F54 T5HO HP90 Surface 2' x 4' Luminaire: with linear prismatic lens. Ballast: QT1X54/120PHO Report is based on 4400 lumens per lamp. Efficiency: 83.6% Spacing Criteria: Shielding Angles: 0-Deg. 90-Deg. 1.2 1.4 90 90 Plane: 0-Deg. 90-Deg. Luminous Length: 47.880 23.040 2.280 2.280 Height of Side: Candela Distribution Coefficients of Utilization Vertical Angle Ceiling Wall RC RW 1 2 3 4 5 6 7 8 9 10 0 5 15 25 35 45 55 65 75 85 90 0 1053 1046 997 906 781 626 452 272 121 26 5 Horizontal Angle 45 90 1053 1053 1047 1051 1015 1033 955 996 868 937 760 864 641 777 516 677 392 568 282 469 179 338 Zonal Lumens 100 287 440 541 581 562 492 391 284 Zonal Lumen Summary CIE Type: Direct - Indirect Plane: REPORT NUMBER: G2008213 DATE: 8/06/08 PREPARED FOR: LIGHTOLIER CATALOG NUMBER: HDS2GLW154 LAMP: (1) F54T5 LUMINAIRE: SEMI RECESSED 2X4 HP90 BALLAST: QT1X54/120PHO SYLVANIA BALLAST 60.78W, LENS W/ OVERLAY REPORT IS BASED ON 4400 LUMENS PER LAMP. Room Cavity Ratio Model No. HDB2SLW154UNVPG Zone Lumens % Lamp 0- 30 0- 40 0- 60 0- 90 90-180 0-180 827 1368 2511 3678 0 3678 18.8 31.1 57.1 83.6 0 83.6 % Fixt. 22.5 37.2 68.3 100.0 0 100.0 80% 50% 30% 70 50 30 50 30 10 50 30 10 Zonal Cavity Method Effective Floor Reflectance = 20% 88 83 79 78 74 71 74 71 69 79 71 65 67 61 57 64 59 55 72 62 54 58 52 47 56 50 46 66 54 46 51 44 39 49 43 39 60 48 40 46 39 34 44 38 33 55 43 35 41 34 29 40 34 29 51 39 31 37 31 26 36 30 25 48 36 28 34 28 23 33 27 23 45 33 26 31 25 21 30 25 20 42 30 23 29 23 19 28 22 18 Average Luminance data in candela / sq. meter Angle 45 55 65 75 85 0˚ 1187. 1036. 820. 558. 271. Job Information 45˚ 1407. 1421. 1482. 1670. 2473. Type: 90˚ 1562. 1667. 1856. 2251. 3547. HP90 Surface Surface 2'X4' Fluorescent; T5 or T5HO Page 3 of 3 Performance In an installation of 2 lamp 28W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .88. To reduce glare the average brightness at 65° shall not exceed 2446 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 77.5%. Photometry LER = 58.1 IW = 30.6 BF = 1.0 Comparative yearly lighting energy cost per 1000 lumens = $4.13 Report Number: G2008221A Catalog Number: HDB2SLW128UNVPG Lamps: (1) F28 T5 Luminaire: Ballast: ICN-2S28 HP90 Surface 2' x 4' with linear prismatic lens. Report is based on 2750 lumens per lamp. Efficiency: 87.0% 0-Deg. 90-Deg. 1.2 1.4 Spacing Criteria: Shielding Angles: 90 90 Plane: 0-Deg. 90-Deg. Luminous Length: 47.880 23.040 2.280 2.280 Height of Side: Coefficients of Utilization Vertical Angle Ceiling Wall RC RW 1 2 3 4 5 6 7 8 9 10 0 5 15 25 35 45 55 65 75 85 90 0 679 675 645 587 507 408 295 179 81 18 4 Horizontal Angle 45 679 676 657 619 563 495 417 336 256 184 121 90 679 678 668 645 607 561 505 440 370 307 225 Zonal Lumens 64 186 285 351 378 366 320 255 187 Zonal Lumen Summary CIE Type: Direct - Indirect Plane: Candela Distribution REPORT NUMBER: G2008221 DATE: 08-19-08 PREPARED FOR: LIGHTOLIER CATALOG NUMBER: HDS2GLW128 LAMP: (1)F28 T5 LUMINAIRE: HP90 SEMI RECESSED BALLAST: ICN-2S28 (ADVANCE), 33.31W LENS W/ OVERLAY REPORT IS BASED ON 2750 LUMENS PER LAMP. Room Cavity Ratio Model No. HDB2SLW128UNVPG Zone Lumens % Lamp 0- 30 0- 40 0- 60 0- 90 90-180 0-180 535 886 1630 2392 0 2392 19.5 32.2 59.3 87.0 0 87.0 % Fixt. 22.4 37.1 68.1 100.0 0 100.0 80% 50% 30% 70 50 30 50 30 10 50 30 10 Zonal Cavity Method Effective Floor Reflectance = 20% 92 87 82 81 77 74 77 74 71 83 74 67 69 64 59 66 62 58 75 64 56 60 54 48 58 52 48 68 57 48 53 46 41 51 45 40 63 50 42 47 40 35 46 39 34 58 45 37 43 36 30 41 35 30 53 41 33 39 32 27 37 31 26 50 37 29 35 29 24 34 28 24 46 34 27 32 26 21 32 25 21 43 31 24 30 24 19 29 23 19 Average Luminance data in candela / sq. meter Angle 45 55 65 75 85 0˚ 774. 676. 540. 373. 188. 45˚ 916. 924. 965. 1091. 1614. 90˚ 1014. 1083. 1206. 1466. 2322. Photometry LER = 83.7 IW = 54.1 BF = 0.93 Comparative yearly lighting energy cost per 1000 lumens = $2.87 Report Number: G2008223A Catalog Number: HDB2SLW228120WA Lamps: (2) F28 T5 HP90 Surface 2' x 4' with linear prismatic lens. Ballast: ST232120E (WA) Luminaire: Report is based on 2750 lumens per lamp. Efficiency: 88.5% Spacing Criteria: Shielding Angles: 0-Deg. 90-Deg. 1.2 1.4 90 90 Plane: 0-Deg. 90-Deg. Luminous Length: 47.880 23.040 2.280 2.280 Height of Side: Coefficients of Utilization Vertical Angle Ceiling Wall RC RW 1 2 3 4 5 6 7 8 9 10 0 5 15 25 35 45 55 65 75 85 90 0 1396 1388 1325 1207 1042 840 608 370 170 37 7 Horizontal Angle 45 1397 1390 1347 1266 1150 1011 855 688 517 363 222 90 1396 1394 1368 1315 1241 1150 1034 892 729 573 404 Zonal Lumens 132 381 583 718 775 751 655 513 357 Zonal Lumen Summary CIE Type: Direct - Indirect Plane: Candela Distribution REPORT NUMBER: G2008223 DATE: 8-20-08 PREPARED FOR: LIGHTOLIER CATALOG NUMBER: HDS2GLW228 LAMP: (2)F28T5 LUMINAIRE: HP90 SEMI RECESSED BALLAST: ST232120E (WA), 54.09W WHITE BALLAST COVER/ LENS W/ OVERLAY REPORT IS BASED ON 2750 LUMENS PER LAMP. Room Cavity Ratio Model No. HDB2SLW228120WA Zone Lumens % Lamp 0- 30 0- 40 0- 60 0- 90 90-180 0-180 1097 1815 3340 4866 0 4866 19.9 33.0 60.7 88.5 0 88.5 Philips Lightolier e: lol.webmaster@philips.com t: (508) 679-8131, Technical info. (978) 657-7600 w: www.lightolier.com % Fixt. 22.5 37.3 68.7 100.0 0 100.0 80% 50% 30% 70 50 30 50 30 10 50 30 10 Zonal Cavity Method Effective Floor Reflectance = 20% 94 88 83 82 79 75 79 76 73 84 76 69 71 65 60 68 63 59 76 66 58 61 55 50 59 53 49 69 58 49 54 47 42 52 46 41 64 51 43 48 41 36 47 40 35 59 46 38 44 36 31 42 36 31 54 42 33 39 32 27 38 32 27 51 38 30 36 29 24 35 29 24 47 35 27 33 26 22 32 26 22 44 32 25 31 24 20 30 24 20 Average Luminance data in candela / sq. meter Angle 45 55 65 75 85 0˚ 1593. 1394. 1116. 783. 386. Job Information HP90 Surface 2X4 July 17, 2012 Specifications are subject to change without notice. © Koninklijke Philips Electronics N.V., 2012. All rights reserved. 45˚ 1871. 1895. 1976. 2203. 3183. Type: 90˚ 2079. 2218. 2446. 2889. 4333.