Installation Instructions: Ceiling and Wall Mount Bracket for 4-Foot GFF Fixture Part Number: GFF-CWMB INSTR Junction Box Engineered Products Company GFF Series Wall Mount Bracket is the efficient and secure method to install the GFF Series Lighting Fixtures to side walls and ceilings. 1. Center the Mounting Bracket directly over the junction box where the GFF Series Light Fixture will be installed. The Mounting Bracket includes slotted holes to simplify and expedite installation. 2. Use the slotted holes as a template and install mount- ing hardware that is suitable for the surface where you will attach the Wall Mount Bracket. To ensure a secure installation, use a minimum of two (2) fasteners located at the outer areas on the Mounting Bracket as shown in Figure 1. Slotted Holes Mounting Bracket - shown from underside Figure 1. Locating and installing the Mounting Bracket to the Junction Box. Mounting Bracket Clips (4) Note: Select mounting hardware that is intended for the surface where you will secure the GFF Fixture. 3. Secure the Mounting Bracket firmly to the mounting surface. Install the GFF Series Light Fixture into the Mounting Bracket by centering the Fixture so the four (4) clips on the Mounting Bracket are positioned just inside the area where the four (4) polycarbonate or stainless latches are located. See Figure 2. Now push Figure 2. Securing the GFF Fixture Housing to the the Fixture up and into the Mounting Bracket until it Mounting Bracket. “snaps” into place. 4. Remove the protective lens from the GFF Fixture housing by opening (or unlatching) the eight (8) polycarbonate or stainless latches. 5. The gear tray should be removed at this time. Squeeze the two (2) metal retaining clips together on the top of the gear tray, then rotate it backward to expose the ballast and Fixture wiring. Supply conductors must be fed from the junction box and through the center hole in the fixture housing Note: The gear tray is tethered to the Fixture housing. 6. Figure 3. GFF Light Fixture Housing shown with the Feed and then connect the supply conductors from Gear Tray and Protective Lens removed. the junction box through the center hole in the Fixture housing (see Figure 3) directly to the “yellow” luminaire disconnect which is color-coded for circuit wiring. The “black” conductor must be connected to the “black“ Port 1”. The “white“ conductor must be connected to the “white” Port 2”, and the green conductor connected to the Ground. See Figure 4. Caution: Termination of the Black and White supply line conductors to the Black and White conductor wires on the GFF Fixture is critical to maintain the correct polarity. Port 1 Port 2 Figure 4. GFF Lighting Fixture Luminaire Disconnect circuit wiring for Ports 1 and 2. Engineered Products Company • 5401 Smetana Drive • Minnetonka, MN 55343 (800) 336-1976 • Fax (800) 336-2801 • engproducts.com P/N: GFF-CWMB INSTR A1 (6/11 - AGIII) Installation Instructions: Ceiling and Wall Mount Bracket for 8-Foot GFF Fixture Part Number: GFF-CWMB INSTR Junction Box 1. Center the Mounting Bracket directly over the junction box where the 8-Foot GFF Series Light Fixture will be installed. 2. Use the slotted holes on the Mounting Bracket as a template and install mounting hardware that is suitable for the surface where you will attach the Mounting Bracket. To ensure a secure installation, use a minimum of two (2) fasteners located at the outer areas on the Mounting Bracket as shown in Figure 1. Note: Select mounting hardware that is intended for the surface where you will secure the GFF Fixture. 3. 4. Secure the Mounting Bracket mounting surface. Install the 8-foot GFF Series Light Fixture into the Mounting Bracket by centering the Fixture so the four Mounting Bracket Clips (4) (4) clips on the Mounting Bracket are positioned just inside the area where the four (4) polycarbonate or stainless steel latches are located. See Figure 2. Note: Because of the GFF Series Light Fixture 8-Foot length, an assistant may necessary to hold the Fixture in place until both Mounting Brackets areinstalled. Slotted Holes Mounting Bracket - shown from underside Figure 1. Locating and installing the Mounting Bracket to the Junction Box. Position the smaller Mounting Bracket on the 8-Foot GFF Series Light Fixture approximately 48 to 64 inches away (but no more than 64 inches) from the larger Mounting Bracket. Use the slotted hole as a template and install smaller Mounting Bracket. See Figure 3. Now push the Fixture up and into the large and small Mounting Brackets until it “snaps” into place. Figure 2. Securing the GFF Fixture Housing to the Mounting Bracket. Large Mounting Bracket 5. Remove the protective lens from the GFF Fixture housing by opening (or unlatching) the fourteen (14) polycarbonate or stainless latches. 6. The Gear Tray should be removed at this time. Squeeze the three (3) metal retaining clips together on the top of the Gear Tray, then rotate it backward to expose the ballast and Fixture wiring. Small Mounting Bracket 64 48 In In ch ch es es M M in ax im um um im Note: The Gear Tray is tethered to the Fixture Housing. 7. Feed and then connect the supply conductors from the junction box through the center hole in the Fixture Housing (see Figure 3) directly to the “yellow” luminaire disconnect which is color-coded for circuit wiring. The “black” conductor must be connected to the “black“ Port 1”. The “white“ conductor Figure 3. Installation and Alignment of the Small must be connected to the “white” Port 2”, and the green conductor Mounting Bracket. connected to the Ground. See Figure 4. Caution: Termination of the Black and White supply line conductors to the Black and White conductor wires on the GFF Fixture is critical to maintain the correct polarity. Port 1 Port 2 Figure 4. GFF Light Fixture Luminaire Disconnect circuit wiring for Ports 1 and 2. Engineered Products Company • 5401 Smetana Drive • Minnetonka, MN 55343 (800) 336-1976 • Fax (800) 336-2801 • engproducts.com P/N: GFF-CWMB INSTR A1 (6/11 - AGIII)