r Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com HEAVYCON Modular Contact carriers To determine the matching housings , refer to the cross-reference list o n page 162 . The axial screw modules cover the uppe r power range . Advantages : —The conductor is connected using a common hexagon socket screw key . Crimping pliers are not necessary. —The male insert is equipped with a protective collar to protect the contact s against mechanical damage . —The modules are polarized . This makes i t impossible to plug them in incorrectly. The modules are mounted with the hinge d retaining frames (see pagel91) in the type B housings (see page192 to 205) . Note : Only use axial screw modules in the hinged retaining fram e (see page 191) . Only stranded conductors can be connected . For type B HEAVYCON housings, see page192 to 205 . The axial screw contacts are included in the module. HC-M-02-MOD.. . 2-pos. axial screw module incl . contact s Descriptio n Type Order No. HC-M-02-MOD-BU HC-M-02-MOD-ST 16 79 35 9 16 79 34 6 Pcs . Pkt. Contact insert module, 2-pos . with female contacts with male contacts Female contact insert module to take CK 2,5 .. . crimp contacts I Male contact insert module, to take CK 2,5 . . . crimp contact s Accessorie s Crimp contacts and crimping tool s Technical dat a Rated current Rated voltage Test voltage Connection cross sectio n Axial screw connection Crimp connection Conductor diameter (including insulation) Torque Contamination class/Surge voltage category Ambient temperature Inflammability in acc. with UL 94 Insertion/withdrawal cycles Rated voltage in acc. with UUCSA Approvals Conductor cross section [mm 2] 1 .5 2 .5 4 6 AWG 16 14 12 10 [A ] [V ] [kV ] 40 100 0 4 [m m2 ] / AW G [m m2 ] / AW G [mm ] [Nm ] 2 .5-10 .0 / 14- 8 [°C ] [V] Stripping section length of the wire A [mm ] 9 9 9 .6 9 .6 - 34,2 - -14,6 - Correlation between stripping length and conductor cros s sectiont Dimensional drawing : HC-M-02-MOD-B U 34,2 1 - 14,6 - - 2mm Operating instructions for axial screw modul e HC-M-02-MOD .. . Dimensional drawing : HC-M-02-MOD-ST a 70 a 60 U m 50 40 a p 30 20 10 20 30 40 50 60 70 80 90 100 110 120 13 0 Ambient temperature [°C] Derating diagram : HC-M-02-MOD. . . 184 Phoenix Contact 2 HC-M-03-MOD- . .. HC-M-06-MOD-.. . HC-M-08-MOD-.. . 3-pos, without crimp contacts 6-pos, without crimp contacts 8-pos, without crimp contacts .1 Order No . Pcs. Pkt . Order No . Type I Pcs. Pkt . Type Order No. Pcs . Pkt . HC-M-03-MOD-BU I 16 63 22 6 2 HC-M-06-MOD-BU I 16 63 46 2 2 HC-M-08-MOD-BU 1605003 2 HC-M-03-MOD-ST 16 63 21 2 HC-M-06-MOD-ST I 16 63 45 9 2 HC-M-08-MOD-ST 1605002 2 . . ., see page 2271 3ForcimpntasCK4,0 For crimp contacts CK 2 .5 . . ., see page 227 For crimp contacts CK 2.5. . ., see page 221,1 40 400 / 690 3 16 50 0 3 16 40 0 3 1 .5-6.0 / 16-10 0 .5-4 .0 / 20-12 0 .5-4.0 / 20-1 2 3/II I -40 to +12 5 VO 500 60 0 an 911 applied fo r - 34,2 - - 34,2 - - 7 ~- 14,6 -_I 1 1 .11 Dimensional drawing : HC-M-03-MOD-BU Dimensional drawing : HC-M-06-MOD-B U Dimensional drawing : HC-M-08-MOD-B U 34, 2 342_ Dimensional drawing : HC-M-03-MOD-ST 14,6 - - Dimensional drawing : HC-M-06-MOD-ST 34,2- - - 14,6 - Dimensional drawing : HC-M-08-MOD-ST 20 a 1 5 a n 1 0 0 5 5 20 30 40 50 60 110 120 130 Ambient temperature [°C] 70 80 90 100 Derating diagram : HC-M-03-MOD. . . 20 30 40 50 90 100 110 120 13 0 Ambient temperature [°C] 60 70 80 Derating diagram : HC-M-06-MOD. .. 20 30 40 50 90 100 110 120 130 Ambient temperature [°C] 60 70 80 Derating diagram : HC-M-08-MOD .. .