THREE MR WL recessed low voltage Spec Sheet LOW VOLTAGE 2-232 wallwasher features Three MR WL is a 3” aperture lensed wallwasher designed for use with 12-volt MR-16 flood lamps (65-watt maximum, see note below). The integral electronic transformer delivers 11.8 volts, to lengthen lamp life. Recess depth is only 6”. The optical assembly consists of a lamp holder, an internal reflector, a 40° x 70° glass spread lens and an external reflector. Precise optical design provides uniform illumination on vertical surfaces up to the ceiling line and minimizes aperture brightness. The optical assembly provides 360° horizontal rotation and may be removed from the fixture housing as a unit for easy relamping. With a 65-watt lamp, Three MR WL accepts one of a number of Optical Accessories including a UV filter and various color filters. With a 50-watt lamp, an additional five Optical Accessories are available. Reflectors are available in three clear natural aluminum finishes –– semispecular (C), slightly diffuse (V) or fully diffuse (EC) –– as well as champagne gold or black Alzak®. Other reflector finishes are available on special order. Requires ceiling opening of 3 ¾” (95mm) for Overlap or Flush Detail. Requires ceiling opening of 4” (102mm) for Trim Flush Detail. PRODUCT CODE For complete product code, list basic unit and select one item from each following box. Basic Unit................................................................THREE-MR-WL Three MR WL includes a pair of mounting bars (¾” x 27” C channel). Specialty Reflector Color and Detail Overlap Trim Flush* Semi-specular Clear.............................. COL..........................CTF Slightly diffuse Clear............................. VOL.......................... VTF Fully diffuse Clear............................... ECOL.......................ECTF Champagne Gold................................ GOL........................ GTF Black.................................................. BOL.......................... BTF bars for wood joist and T-bar installations are also available. applications Fixture is recommended for wallwahing in stores, offices, museums, restaurants, showrooms, residences and hotels. Fixture is listed for Damp Location. Fixture includes an integral electronic transformer protected by a thermal auto-reset switch. Fixture is prewired with thermal protector, suitable for use in a fire rated ceiling and approved for ten #12 wire 90°C branch circuit pull-through wiring. Removal of the reflector allows access to the transformer and junction box. Standard reflector flange continues reflector finish. White painted flanges and custom painted flanges are available on special order. Add WF (white flange) or CCF (custom color flange). *Trim Flush reflector trim requires the use of a plaster ring Accessory (see below). Reflectors detailed for metal or wood ceilings available on special order. OPTIONS Specify by adding to the basic unit. Integral 277/12 volt electronic transformer ........................ – SS277 No transformer. With leads and thermal protector for 12-volt service from remote transformer (by others) ............ – NXFMR OPTICAL accessories Specify as separate line items. All are 2 3/8” (60mm) dia. Lenses and filters are glass; screens are aluminum. UV filter......................................................................UVF/2.375 color filters Daylight Blue ........................................................... DAY/2.375 Surprise Pink ............................................................ PNK/2.375 amber ......................................................................AMB/2.375 blue (50-watt max. lamp) . ............................................. BLU/2.375 green (50-watt max. lamp) .......................................... GRN/2.375 red (50-watt max. lamp) .............................................. RED/2.375 33% light reduction screen (50-watt max. lamp).............SCR33/2.375 50% light reduction screen (50-watt max. lamp).............SCR50/2.375 To minimize socket/lamp problems we recommend the use of lamps by GE, Sylvania, Philips or Ushio. In addition, in areas of high ambient temperatures the lamp should be limited to 50 watts. Important installation note: If controlled by a dimmer, use dimming equipment compatible with the design (electronic or magnetic) of the fixture transformer. accessories Specify as a separate line item. Plaster ring allows use of 3¾” OD Trim Flush (-TF) reflector in sheetrock ceiling; 4” dia hole required............TF RING/3 MODIFICATIONs AVAILABLE Contact factory with quantity for pricing; orders may require shop drawing approval. +TR:luminaire prepared for top re-lamping; add +TR to Product Code. +DOD:luminaire suitable for high humidity environments; add +DOD to Product Code. +MAR:reflector suitable for marine environments; add +MAR to Product Code. 41-50 22ND STREET, L IC NY 11101 © Copyright, Edison Price Lighting 2015 tel 718.685.0700 fax 718.786.8530 www.epl.com 9:15 THREE MR WL PHOTOMETRIC REPORT CANDLEPOWER DISTRIBUTION Luminaire Testing Laboratory Report No. 20503. Original test report furnished upon request. Luminaire.................recessed incandescent with internal wallwash reflector and 40° x 70° spread lens WALLWASH INFORMATION 50-watt MR16 quartz FL40 (EXN), 880 lumens (estimated) Distance From Ceiling (Feet) 2’6 From Wall; 2’6” O.C. Below Between Fixture Fixtures 3’ From Wall; 3’ O.C. Below Between Fixture Fixtures 1 11 9 7 6 2 14 12 9 8 3 14 12 10 9 4 12 11 9 8 5 9 9 8 7 6 7 7 6 6 7 6 6 5 5 8 5 4 4 4 9 4 4 4 4 All vertical footcandles are initial values with no contribution from ceiling or floor reflectances. Computation performed with a total of ten wallwashers. WALLWASH INFORMATION 65-watt MR16 quartz FL (FPB), 1144 lumens (estimated) Distance From Ceiling (Feet) 2’6” From Wall; 2’6” O.C. Below Between Fixture Fixtures 3’ From Wall; 3’ O.C. Below Between Fixture Fixtures 3’6” From Wall; 3’6” O.C. Below Between Fixture Fixtures 1 14 12 9 7 6 5 2 18 15 12 10 8 7 3 18 16 13 11 9 8 4 15 14 12 11 9 8 5 12 12 10 10 8 8 6 9 9 8 8 7 7 7 7 7 7 7 6 6 8 6 6 6 6 5 5 9 5 5 5 5 4 4 10 4 4 4 4 All vertical footcandles are initial values with no contribution from ceiling or floor reflectances. Computation performed with a total of ten wallwashers.