Bussmann® North American 1000-4000A FWA 130V ® Electrical Characteristics Ordering Information I2t (A2 Sec) Rated Current Clearing Watts Part Carton RMS-Amps Pre-arc at 130V Loss Number Qty. 1000 170000 460000 60 FWA-1000AH ______________________________________________________________________________________ Type Dimensions Curves Carton Weight (lbs) Figure Number See Page 3.3 Fig. 1 1200 270000 730000 70 FWA-1200AH ______________________________________________________________________________________ 1500 520000 1400000 78 FWA-1500AH ______________________________________________________________________________________ FWA 2000 860000 2400000 108 FWA-2000AH 130V ______________________________________________________________________________________ 2500 1500000 4100000 130 FWA-2500AH ______________________________________________________________________________________ 3000 2100000 5700000 150 FWA-3000AH ______________________________________________________________________________________ 4000 3400000 9200000 257 page 21 1 ______________ Fig. 2 FWA-4000AH Interrupting rating 200kA RMS Symmetrical. Watts loss provided at rated current. (130 Vdc/Interrupting Rating 50kA) U.L. Recognition on 1000 through 2000 amperes. See accessories on page 20. 1 kg = 2.2 lbs 1 lb = 0.45 kg Electrical Characteristics Total Clearing I2t The total clearing I2t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K, given as a function of applied working voltage, E g , (RMS). Arc Voltage This curve gives the peak arc voltage, U L , which may appear across the fuse during its operation as a function of the applied working voltage, E g , (RMS) at a power factor of 15%. 1.5 K Power Losses Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, K p , is given as a function of the RMS load current, Ib , in % of the rated current . 1.0 Kp 0.8 UL 1.0 0.6 0.5 300 0.4 0.5 0.2 0.3 0.2 0.15 26 0.3 200 100 Eg Eg 65 104 130 50 100 Ib 0.1 150 30 40 50 60 70 80 90 100% BIF document: 720001 6 For complete specification data, visit our Web site at www.bussmann.com or call Bussmann Information Fax ~ 636.527.1450 Bussmann® North American FWA 130V 1000-4000A ® Dimensions Fig. 1: 1000-3000 Amp Range Fig. 2: 4000 Amp Range 1.875 1.875 D B B C Order # FWA-1000AH-2000AH FWA-2500AH-3000AH FWA-4000AH Fig. 1 1 2 B 2.0 3.0 3.5 C 1.0 1.5 1.5 D — — 1.5 C Thread Depth Tapped ‹Ω•∑-24 ≈ ⁄Ω™∑ Tapped ⁄Ω™∑-20 ≈ ⁄Ω™∑ Tapped ⁄Ω™∑-20 ≈ ⁄Ω™∑ Dimension in inches. 1mm = 0.0394∑ 1∑ = 25.4mm BIF document: 720001 For complete specification data, visit our Web site at www.bussmann.com or call Bussmann Information Fax ~ 636.527.1450 7 Bussmann® North American 70-1000A FWA 150V Rated Current RMS-Amps Type ® Electrical Characteristics I2t (A2 Sec) Clearing Pre-arc at 150V Ordering Information Watts Loss Part Number Dimensions Carton Qty. Carton Weight (lbs) Figure Number 1 1.76 Fig. 1 Curves See Page 70 470 4000 6.9 FWA-70B _____________________________________________________________________________________ 80 670 6000 7.7 FWA-80B ____________________________________________________________________________________ __ 100 1200 12000 9.0 FWA-100B __ ____________________________________________________________________________________ 125 1870 18000 11.2 FWA-125B _____________________________________________________________________________________ 150 2700 26000 13.5 FWA-150B _____________________________________________________________________________________ 200 4780 45000 17.6 FWA-200B _____________________________________________________________________________________ page 21 250 7470 70000 22.5 FWA-250B _____________________________________________________________________________________ FWA _______________________________________________________________________________ 300 10760 100000 27.0 FWA-300B_____ 150V 350 15700 140000 30.6 FWA-350B _____________________________________________________________________________________ 400 20300 180000 35.2 FWA-400B __________________________________________________________________________________________________________________________ 500 39000 120000 35.0 FWA-500A _____________________________________________________________________________________ 600 46000 140000 47.0 FWA-600A _____________________________________________________________________________________ 700 75000 220000 49.0 FWA-700A _____________________________________________________________________________________ 5 2.42 Fig. 2 800 92000 280000 58.0 FWA-800A _____________________________________________________________________________________ 1000 170000 510000 60.0 FWA-1000A Interrupting rating 100kA RMS Symmetrical for ampere ratings 70-400. Interrupting rating 200kA RMS Symmetrical for ampere ratings 450-1000. Watts loss provided at rated current. (150 Vdc/Interruting rating 20kA) U.L. Recognition on 70- 800 amperes. (80 Vdc/Interruting rating 100kA) U.L. Recognition on 70-400 amperes. See accessories on page 20. 1 kg = 2.2 lbs 1 lb = 0.45 kg Electrical Characteristics Total Clearing I2t The total clearing I2t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K, given as a function of applied working voltage, E g , (RMS). Power Losses Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, K p , is given as a function of the RMS load current, Ib , in % of the rated current . Arc Voltage This curve gives the peak arc voltage, U L , which may appear across the fuse during its operation as a function of the applied working voltage, E g , (RMS) at a power factor of 15%. 1.5 K 1.0 Kp 0.8 UL 1.0 0.6 0.5 300 0.4 0.5 1) 200 2) 100 0.3 0.2 0.3 0.2 0.15 22 Eg Eg 70 102 150 Ib 0.1 50 100 150 30 40 50 60 70 80 90 100% 1) 500-1000 Amp Range 2) 70-400 Amp Range BIF document: 720002 8 For complete specification data, visit our Web site at www.bussmann.com or call Bussmann Information Fax ~ 636.527.1450 Bussmann® North American FWA 150V 70-1000A Dimensions Fig. 1: 70-400 Amp Range 2.656 2.188 1.936 1.156 0.125 0.750 0.312 1.000 0.438 Fig. 2: 500-1000 Amp Range 3.500 2.438 1.250 1.000 0.250 1.500 0.406 Dimension in inches. 1mm = 0.0394∑ 1∑ = 25.4mm BIF document: 720002 For complete specification data, visit our Web site at www.bussmann.com or call Bussmann Information Fax ~ 636.527.1450 9 Bussmann® North American Curves FWX 250V (35-800)A FWX 250V (1000-2500)AH Time-Current Curve Time-Current Curve 104 6 4 104 2 103 FWX-200A FWX-350A FXW-400A FWX-500A FWX-600A FWX-800A 102 2 FWX-1000AH FWX-1200AH FWX-1500AH FWX-1600AH FWX-2000AH FWX-2500AH 102 6 4 101 2 100 Virtual Pre-Arcing Time In Seconds Virtual Pre-arcing Time In Seconds 103 6 4 FWX-35A FWX-40A FWX-60A FWX-70A FWX-100A FWX-150A 10–1 10–2 10–3 101 6 4 2 100 6 4 2 10–1 6 4 10–4 2 102 103 Prospective Current In Ampere RMS 2 104 10–2 6 4 2 10–3 6 4 2 10–4 2 103 Peak Let-Through Curve 4 6 8 2 4 6 104 Prospective Current In Amperes RMS 8 105 Peak Let-Through Curve 105 105 B 6 FWX-2500AH 4 Peak Let-Through Current FWX-800A FWX-600A FWX-400A FWX-300A FWX-200A Peak Let-Through Current 104 FWX-2000AH FWX-1600AH FWX-1500AH FWX-1200AH 2 FWX-1000AH 104 6 4 2 10 3 FWX-150A FWX-100A FWX-70A FWX-60A FWX-45A FWX-35A A 102 102 103 104 103 103 2 4 6 104 2 4 6 105 2 Prospective Short-Circuit Current Symmetrical RMS 105 Prospective Short-Circuit Current Symmetrical RMS BIF document: 359 22 BIF document: 35785299 For complete specification data, visit our Web site at www.bussmann.com or call Bussmann Information Fax ~ 636.527.1450 4 6