IG224/4 4-Channel-Loop-Detector

advertisement
IG224/4
4-Channel-Loop-Detector
Card plug for rack system
Application range
•
•
•
•
Signal output for traffic light installations
Counting of traffic
Bus classification, car / lorry classification
Special options
Detection of traffic jams
Speed measuring
Features
•
•
•
•
•
•
•
•
•
•
•
•
High noise immunity
Permanent loop control
Ferrite control
Card plug-in for rack system with direct connector
Comfortable operation via manual terminal or PC software, great adjustability
RS 485 interface and RS 232 interface
Operational parameters saved in EEPROM
Low power consumption
Various output functions:
Presence signal
Impulse signal
Directional signal
Adjustable switch on/off delay
NEMA (USA) Standard
Loop feed cable up to 550 m (with ∅ 0.8 mm)
Canoga-compatible version available (e.g. C424, C824)
Functional description
The 4-channel loop detector IG224/4 was especially designed for traffic applications and stands out for its
multitude of special functions. Like the series IG224 and IG224/2, loops are controlled in the noise immune
multiplex mode. Besides the usual switching outputs, this detector has a RS485 data-bus interface.
Subject to technical modification.
IG224_4_DE_35
© Weiss-Electronic GmbH
Tel.: +49 (0) 6 51 / 8 10 02 – 0
1
IG224/4
4-Channel-Loop-Detector
Card plug for rack system
The oscillator can be adjusted to very low loop inductivities by a jumper (single-turn loops). For inductivities
of 400 µH and more a resistance of 40 Ohm is permitted (corresponds to approx. 550 m feed cable with
∅ = 0.8 mm). The front-side service interface can be used to adjust via laptop (service software IGBT)
multiple channel parameters like: sensitivity, measuring time, hold time, operational frequency, switch on/off
delay, directional logic and oversampling.
The software is also designed for the diagnosis of loops and detectors, and for activating special functions.
Classification function
A bus detection can be implemented by using a special loop (10 m x 2.5 m, 2 windings). The value of
attenuation is the decisive criterion. For smaller loops (loop length: 1,0 m– 2,5 m) a simple differentiation
between car / lorry can be realised.
Synchronization
Crosstalk of loops and their feeder cable can be eliminated by synchronizing up to 30 detectors.
Dimensions
179 mm
5 TE
RS232
LAMPS
RESET
CH 1
114 mm
CH 2
CH 3
CH 4
ERROR
TRANS.
FUNC.
IG224/4
193 mm
Dimensions are subject to manufacturer's tolerances
Subject to technical modification.
IG224_4_DE_35
© Weiss-Electronic GmbH
Tel.: +49 (0) 6 51 / 8 10 02 – 0
2
4-Channel-Loop-Detector
IG224/4
Card plug for rack system
† Technical data
Power supply
standard: (12 - 24) V DC, tolerance: (10.8 - 30) V DC
optional: 5 V DC +/-5 %
Power consumption
max. 1.2 W, typical: 0.8 W at 24 V DC (opto-coupler version)
Operating temperature range
in accordance with DIN VDE 0832
Storage temperature range
-40°C to +80°C
Inductivity range
20 µH - 2000 µH (recommended range: 80 µH to 300 µH)
Sensitivity per channel
9 levels, max. 0.007 % to min. 0.5 % (frequency change ∆f/f0 in %)
Measuring time per channel
10 levels: min. 2.5 ms to max. 45 ms
Hold time per channel
10 levels: tmin = 1 s to tmax = ∞
Tuning
automatic after a few seconds:
- after switching on power supply
- after pushing RESET key
- after external RESET command
- after change of parameters via manual controller or PC
Outputs
switching output per channel: opto-coupler
fault detection per channel: open collector
general failure report: opto-coupler
optional: electromechanical / electronic relay
Safety
power supply: suppressor - diode
loop inputs: glow lamps, Z-diodes, transmitter
Dimensions
front panel: W: 25,40 mm (optional: 50,80 mm), H: 114 mm
Connections terminal
direct plug connector (Cinch-Jones 50-44A 3011 or similar)
Weight
approx. 200 g
Technical Data of outputs
OC
Electromechanical
relay
Electronic relay
Opto-Coupler
Open Collector
RESET external
C
C
induction
AC/DC
AC/DC
0V DC
0V DC
•
Open Collector
U max = 48 V
Imax = 300 mA
Ptot = 250 mW
Ic ≤ 20 mA: U CE sat ≤ 0.4 V
non-floating output
Subject to technical modification.
IG224_4_DE_35
A
E
•
Opto-coupler
U max = 48 V
Imax = 50 mA
P tot = 100 mW
Ic ≤ 10 mA: U CE sat ≤ 0,4 V
floating output
•
Electronic relay
•
Electromechanical
relay
U max = 40 V AC / DC
Imax = 0.2 A Peak AC / DC
P tot = 100 mW
U max = 48 V AC / DC
Imax = 0.5 A AC / DC
floating output
floating output
© Weiss-Electronic GmbH
Tel.: +49 (0) 6 51 / 8 10 02 – 0
3
4-Channel-Loop-Detector
IG224/4
Card plug for rack system
Connections: IG 224/4 Standard
- 1
I
I
A
0V
- 2
I
I
B
+12 V DC - +24 V DC / +5 V DC
I
I
C
RESET external ( low active )
CH1 loop 4
- 3
I---- I
D
CH1 loop
CH1 loop 5
I---- I
E
CH1 loop
CH1 fault detection (OC) 6
I
I
F
CH1 switching output (K)
- 7
I
I
H
CH1 switching output (E)
I---- I
J
CH2 loop
I---- I
K
CH2 loop
I
L
PE
CH2 loop 8
CH2 loop 9
synchronisation 10
I
central fault detection (K) 11
I
I
M
CLK external EEPROM
central fault detection (E) 12
I
I
N
DATA external EEPROM
CH3 loop 13
I---- I
P
CH3 loop
CH3 loop 14
I---- I
R
CH3 loop
CH3 fault detection (OC) 15
I
I
S
CH3 switching output (K)
- 16
I
I
T
CH3 switching output (E)
CH4 loop 17
I---- I
U
CH4 loop
CH4 loop 18
CH4 loop
I---- I
V
CH2 fault detection (OC) 19
I
I
W
CH2 switching output (K)
- 20
I
I
X
CH2 switching output (E)
CH4 fault detection (OC) 21
I
I
Y
CH4 switching output (K)
- 22
I
I
Z
CH4 switching output (E)
(E): emitter (opto-coupler-model)
(K): collector (opto-coupler-model)
(OC): open collector
: PIN not covered
--- : bridged
Connections: IG 224/4 Canoga
- 1
I
I
A
0V
- 2
I
I
B
+12 V DC - +24 V DC / +5 V DC
I
I
C
RESET external ( low active )
CH1 loop 4
- 3
I---- I
D
CH1 loop
CH1 loop 5
CH1 loop
I---- I
E
- 6
I
I
F
CH1 switching output (K)
CH1 fault detection (OC) 7
I
I
H
CH1 switching output (E)
CH2 loop 8
I---- I
J
CH2 loop
CH2 loop 9
I---- I
K
CH2 loop
- 10
I
I
L
PE
synchronisation wire 2 11
I
I
M
CLK external EEPROM
synchronisation wire 1 12
I
DATA external EEPROM
I
N
CH3 loop 13
I---- I
P
CH3 loop
CH3 loop 14
I---- I
R
CH3 loop
- 15
I
I
S
CH3 switching output (K)
CH3 fault detection (OC) 16
I
I
T
CH3 switching output (E)
CH4 loop 17
I---- I
U
CH4 loop
CH4 loop 18
I---- I
V
CH4 loop
RS485-A 19
I
I
W
CH2 switching output (K)
CH2 fault detection (OC) 20
I
I
X
CH2 switching output (E)
RS485-B 21
I
I
Y
CH4 switching output (K)
CH4 fault detection (OC) 22
I
I
Z
CH4 switching output (E)
(E): emitter (optocoupler version)
(K): collector (optocoupler version)
Subject to technical modification.
IG224_4_DE_35
(OC): open collector
: PIN not covered
--- : bridged
© Weiss-Electronic GmbH
Tel.: +49 (0) 6 51 / 8 10 02 – 0
4
IG224/4
4-Channel-Loop-Detector
Card plug for rack system
EC Conformity
This device is an inductive radio transmitter system whose
transmission frequency is not harmonised in the European Union.
EC Declaration of Conformity
Subject to technical modification.
IG224_4_DE_35