Prices as of April 27, 2016. Check Web site for most current prices. Dual Element Time-Delay Class RK5 Fuses ECNR40 ECNR70 These fuses are recommended for AC power distribution system mains, feeders and branch circuits having inductive loads (motors, transformers) or non-inductive loads (lighting, heating) where the available shortcircuit current does not exceed 200,000 RMS symmetrical amperes. These dual element, time-delay fuses have minimum industry standard time-delay of 10 seconds at 5 times the fuse rating (8 sec. minimum for 250V, 30A and less). The time-delay characteristics of these fuses typically allows them to be sized closer to the running ampacity of inductive loads to reduce cost and provide improved overcurrent protection. These fuses will override normal equipment current surges to reduce unnecessary fuse openings. They are the most popular fuses used in the industry and the most economical for most applications, especially motors and transformers. They have moderate current limitation. ECNR/ECSR Features • True dual - element construction allows sizing of 125% FLA for motor backup protection • Superior overload and cycling capabilities • Current limiting; provides component short circuit protection Applications • Recommended for AC power distribution system mains, feeders, and branch circuits • Protection of motors and motor branch circuits • Protection of transformers and other inductive loads • All general-purpose applications including lighting, heating and other non-inductive loads ECNR/ECSR Specifications ECNR150 ECSR100 Voltage Rating: ECNR: 250 VAC ECSR: 600 VAC Ampere Rating: ECNR: 1–600 Amps ECSR: 3–600 Amps Interrupting Rating: 200,000 RMS Symmetrical Amps Self-Certified DC Ratings: • Voltage Rating: ECNR (1–200): 125 VDC ECNR (201–600): 250 VDC ECSR (3–600): 300 VDC • Self-Certified Interrupting Rating: ECNR/ECSR 20,000 Amperes DC Current Limiting: RK5 Fuse Agency Approvals ECSR5 ECSR200 • UL Listed, Class RK5, Guide JDDZ, File E162363 • CSA Certified HRCI-R per C22.2, No. 248.12 CROSS REFERENCE VOLTS EDISON BUSSMANN MERSEN GOULD LITTELFUSE ECNR FRN-R TR FLNR 250 600 ECSR FRS-R TRS FLSR Book 3 (14.3) eCP-150 Circuit Protection 1 - 8 0 0 - 633 - 0 4 0 5 Prices as of April 27, 2016. Check Web site for most current prices. Dual Element Time-Delay Class RK5 Fuses ECNR Series 250V Dual-element Time-delay Fuses Part Number ECNR1 ECNR2 ECNR3 ECNR5 ECNR8 ECNR10 ECNR15 ECNR20 ECNR25 ECNR30 ECNR35 ECNR40 ECNR45 ECNR50 ECNR60 ECNR70 ECNR80 ECNR90 ECNR100 ECNR125 ECNR150 ECNR175 ECNR200 ECNR225 ECNR250 ECNR300 ECNR350 ECNR400 ECNR450 ECNR500 ECNR600 $50.00 2 0.30 lb $50.00 3 $50.00 5 $50.00 8 $50.00 10 $50.00 15 0.50 lb 20 10 $40.50 $40.50 25 $40.50 30 $40.50 35 $70.00 40 $70.00 45 1.00 lb 50 70 $70.00 $70.00 60 $70.00 250V 80 $78.00 5 90 1.50 lb 100 $78.00 $78.00 $78.00 125 0.77 lb 150 175 1.10 lb $36.00 $36.00 $36.00 200 $36.00 225 $52.00 250 1 300 1.52 lb $52.00 $52.00 350 $52.00 400 $52.00 450 $89.00 3.00 lb 500 600 $89.00 $89.00 ECNR/ECSR Dimensions Ferrule Design – 1 through 60 Amperes Terminal Blocks Knife Blade – 70 through 600 Amperes Power Distribution Blocks ECSR Series 600V Dual-element Time-delay Fuses Part Number Rated AMP Voltage Pcs/Pkg Package Price Rating Weight AC Max 1 Company Information ECSR3 ECSR4 ECSR5 ECSR6 ECSR6-25 ECSR7 ECSR8 ECSR10 ECSR12 ECSR15 ECSR17-5 ECSR20 ECSR25 ECSR30 ECSR35 ECSR40 ECSR45 ECSR50 ECSR60 ECSR70 ECSR80 ECSR90 ECSR100 ECSR110 ECSR125 ECSR150 ECSR175 ECSR200 ECSR225 ECSR250 ECSR300 ECSR350 ECSR400 ECSR450 ECSR500 ECSR600 Rated AMP Voltage Pcs/Pkg Package Price Rating Weight AC Max 3 $97.00 4 $97.00 5 $97.00 6 $97.00 6.25 $97.00 7 $97.00 8 1.7 lb 10 12 $97.00 $97.00 $97.00 15 10 $88.00 17.5 $88.00 20 $88.00 25 $88.00 30 $88.00 35 $149.00 40 $149.00 45 3.00 lb 50 $149.00 600V 60 $149.00 $149.00 70 $180.00 80 5 90 50.54 lb 100 $182.00 $180.00 $180.00 110 1.00 lb 125 $62.00 $62.00 150 1.22 lb 175 $62.00 $62.00 200 $62.00 225 $96.00 250 1 300 $96.00 3.00 lb $118.00 350 $96.00 400 $96.00 450 $139.00 500 5.00 lb 600 $139.00 $139.00 Wiring Accessories ZIPLink Connection System Multi-wire Connectors Sensor Cables and Connectors M12 Junction Blocks Panel Interface Connectors Wiring Duct Cable Ties Wire Bulk Multi-conductor Cables Wire Management Products Power Supplies DC Converters Transformers and Filters Circuit Protection Tools Test Equipment Enclosures Enclosure Climate Control Safety: Electrical Components Safety: Protective Wear Terms and Conditions Dimensions inches (mm) Catalog Number Amps Overall Length Max Diameter Catalog Number A B Amps ECNR 250V 1-30 35-60 70-100 110-200 225-400 450-600 2 (50.8) 3 (76.2) 5.88 (149.4) 7.13 (181.1) 8.63 (219.2) 10.38 (263.7) 3-30 35-60 70-100 110-200 225-400 450-600 0.56 (14.2) 0.81 (20.6) 1.06 (26.9) 1.56 (39.6) 2.06 (52.3) 2.59 (65.8) ECSR 600V Overall Length Max Diameter A B 5 (127) 5.5 (139.7) 7.88 (200.2) 9.63 (244.6) 11.63 (295.4) 13.38 (339.9) 0.81 (20.6) 1.06 (26.9) 1.11 (28.2) 1.61 (40.9) 2.34 (59.4) 2.88 (73.2) Book 3 (14.3) w w w. a u t o m a t i o n d i r e c t . c o m / c i r c u i t- p r o t e c t i o n Circuit Protection eCP-151 Prices as of April 27, 2016. Check Web site for most current prices. Dual Element Time-Delay Class RK5 Fuses 600A 400A 200A 100A AMPERE RATING 10 TIME IN SECONDS TIME IN SECONDS 10 60A 100 30A AMPERE RATING 10A . 2A . 3A . 4A . 5A . 6A . 8A 1A 1. 125A 1. 6A 2A 2. 5A 3. 2A 4A 5A 6. 125A . 1A 100 15A AVERAGE TIME/CURRENT CURVES Cat No. ECNR (AMP) 250 VAC ECNR Curves 1 1 .1 10, 000 20, 000 1, 000 .01 10 RMS SYMMETRICAL CURRENTS IN AMPERES 100 600 100 10 .1 .01 1 .1 RMS SYMMETRICAL CURRENTS IN AMPERES ECSR Curves 600A 400A 200A 100A 60A 100 30A AMPERE RATING . 1A . 2A 100 10A 15A . 3A . 4A . 5A . 6A . 8A 1A 1. 125A 1. 6A 2A 2. 5A 3. 2A 4A 5A 6. 125A 8A AVERAGE TIME/CURRENT CURVES Cat No. ECSR (AMP) 600 VAC AMPERE RATING 10 TIME IN SECONDS TIME IN SECONDS 10 1 1 .1 700 100 10 1 .01 .1 .1 20, 000 10, 000 1, 000 100 .01 10 RMS SYMMETRICAL CURRENTS IN AMPERES RMS SYMMETRICAL CURRENTS IN AMPERES Book 3 (14.3) eCP-152 Circuit Protection 1 - 8 0 0 - 633 - 0 4 0 5 Prices as of April 27, 2016. Check Web site for most current prices. Dual Element Time-Delay Class RK5 Fuses Company Information Terminal Blocks Power Distribution Blocks ECNR/ECSR Curves Wiring Accessories ZIPLink Connection System Multi-wire Connectors Sensor Cables and Connectors M12 Junction Blocks Panel Interface Connectors Wiring Duct Cable Ties Wire Bulk Multi-conductor Cables Wire Management Products Power Supplies DC Converters Transformers and Filters Circuit Protection Tools Test Equipment Enclosures Enclosure Climate Control Safety: Electrical Components Safety: Protective Wear Terms and Conditions Book 3 (14.3) w w w. a u t o m a t i o n d i r e c t . c o m / c i r c u i t- p r o t e c t i o n Circuit Protection eCP-153 Prices as of April 27, 2016. Check Web site for most current prices. Selection Guide Line Overview Company Information Terminal Blocks The fuse selection guide below is a general summary of the specifications included for each fuse type. This selection guide does not include the many variables that can exist for specific situations such as local codes, unusual temperature, or other operating conditions. When selecting fuses, be sure to comply with any applicable PUBLIC SAFETY standards that apply to Overcurrent Protection Devices (OPD). The Edison family of fuses, fuse blocks and fuse holders is divided into two classes: 1. Current Limiting: Class CC, Class J, Class L, Class RK, Class T 2. General Purpose: Class M Midget and Small Dimension Edison Fuses Selection Guide and General Specifications Description Class J Fuse Type Fast-Acting Time-Delay Part Number JHL JDL Voltage Rating Amp Rating Interrupting Rating Current Limiting Agency Approvals Dimensions 600VAC 450VDC Current Limiting Class RK1 Class T Class RK5 Time-Delay ECNR ECSR LENRK LESRK TJN 250VAC 250VAC 600VAC 125 VDC* 600VAC 125VDC* 600VAC 300VAC (1-200A) 300VDC* (10-60A) 300VDC* 160 VDC 300VDC* 250VDC* 250VDC* (15-600A) (201-600A) (70-600A) 1 - 600 1 - 600 3 - 600 10 - 600 5 - 600 Class CC Fast-Acting Fast-Acting TJS LCU HCLR 600VAC 600V 600VAC 300VDC (15-20A) 1 - 600 601 - 1200 Time-Delay HCTR 0.5 - 30 EDCC 600VAC 300VDC 600VAC (0.5-2.25A) (20–30A) 0.25 - 30 0.5 - 30 Class RK5 Class RK1 Class T Class L * Self-certified DC ratings Edison Fuses Selection Guide and General Specifications General Purpose – Midget Fuse Type Fast-Acting Part Number Voltage Rating MCL MOL Time-Delay MEQ MEN 250 VAC to 30A) 600 VAC 250 VAC 500 VAC 250 VAC (0.5 125VDC: (0.5 to 30A) Amp Rating 0.5 to 50 0.5 to 30 0.25 to 30 0.5 to 30 Interrupting 100,000 10,000 RMS Amps RMS Amps Rating Current N/A Limiting Agency Approvals ABC UL Listed to 248.14, File E162443 CSA Cert. C22.2 Part 59.2, LR 700489 0.5 to 30 Fast-Acting Glass AGC GMA 250VAC: 250VAC (0.1 to 10A) (0.063 - 3A) 32VAC: 125VAC (15 to 30A) (4 - 15A) 0.10 to 30 0.063 to 15 Medium Time- Time-Delay Time-Delay Fast-Acting Delay Glass Ceramic Glass Glass S500 TimeDelay Glass GMC MDA MDL S506 250VAC (0.5 - 3A) 125VAC (4 - 10A) 250VAC 125VDC (20A) 250VAC: (0.0625 to 8A) 32VAC: (10 to 20A) 250VAC 250VAC 0.5 to 10 0.5 to 20 0.0625 to 20 0.032 to 10 0.25 to 6.3 See specifications table on product pages UL Listed standard 248-14 UL Listed Guide and File nos. Designed to UL/CSA 248-14 (ABC 0.25-20 A): UL Listed, Guide JDYX, File (AGC 1/100-10 A) JDYX and E19180 E19180 63mA-6A UL Recognition Guide and UL Recognition, Guide JDYX2, File nos. (ABC 20-30A):(AGC File E19180, 7A-15A 11-30) CSA Certified, File JDYX2 and E19180 053787_C_000, CSA Certification Record No: 63mA-6A Class 1422-01 053787 C 000 and Class No: 1422 01 and 1422 30 0.197” x 0.788” (5mm x 20mm) UL Listed standard 248-14 UL Listed Card: MDA 2/10-20A , MDL 1/16-8A (Guide JDYX, File E19180 UL Recognized Card: MDA 25-30A MDL 9-30A (Guide JDYX2, File E19180) CSA Certification Card: MDA 2/10-15A (Class No. 1422-01) L Recognized Guide U JDYX2, File E19180 Semko Approval VDE Approval BSI Approval IMQ Approval RoHS compliant 1/4” x 1-1/4”, (6.3mm x 32mm) 0.197” x 0.788” (5mm x 20mm) Book 3 (14.3) w w w. a u t o m a t i o n d i r e c t . c o m / c i r c u i t- p r o t e c t i o n Wiring Duct Bulk Multi-conductor Cables Wire Management Products Power Supplies DC Converters Transformers and Filters Tools Test Equipment Enclosures Safety: Electrical Components Safety: Protective Wear Terms and Conditions N/A 1/4” x 1-1/4”, (6.3mm x 32mm) Panel Interface Connectors Enclosure Climate Control RoHS Dimensions ferrule (in): 13/32 length (in): 1-1/2 M12 Junction Blocks Circuit Protection General Purpose – Small Dimension Electronic Fast-Acting Ceramic Sensor Cables and Connectors Wire Class CC UL Listed Class J UL Listed Guide JDDZ Class J UL Listed, File E162363 Guide JDDZ UL Listed, Class RK, Guide JDDZ, UL Listed, Class T, Std. 248-10 UL Listed to 248.4, Class CC, CSA Certified File E162363 File E162363 Guide JDDZ, File E162363 CSA Certified, Guide JDDZ, File E162363, HRCI-J per CSA Certified CSA Certified HRCI-R per C22.2, No. 248.12, CSA Certified HRCI-T per HRC-L C22.2 certified HRCI-MISC per C22.2 C22.2, HRCI-J per File 700489 C22.2, No. 248.12, File 53787, No. 248.10, CSA No. 248.8 C22.2, No. (LENRK CSA File 053787) Class 1422-02 & 1422-82 Class 1422-02, No. 248.4, File 700489 File 700489 248.8 File 53787 RoHS File 700489 compliant See product specification pages. ferrule (in): 13/32, length (in): 1-1/2 Description ZIPLink Connection System Cable Ties 200,000 RMS Symmetrical Amps Class J Wiring Accessories Multi-wire Connectors Class L Extremely Fast-Acting Power Distribution Blocks Circuit Protection eCP-143 Prices as of April 27, 2016. Check Web site for most current prices. Fuse Blocks for Class RK Fuses Company Information Terminal Blocks Description Agency Approvals • UL Listed, UL 512, Guide IZLT, File E14853 • CSA, Certified, C22.2 No.39 Class 6225-01, File 47235 For use with Edison LENRK and ECNR, R250; Edison LESRK and ECSR, R600, Class R fuses Terminal type : • SR = Screw type, clip with re-inforced spring. • CR = Box lug type, clip with reinforced spring R25030-1SR Power Distribution Blocks Wiring Accessories ZIPLink Connection System Multi-wire Connectors Sensor Cables and Connectors M12 Junction Blocks Specifications Panel Interface Connectors Construction: Thermoplastic UL Flammability: 94V-0 Wiring Duct Voltage Ratings: R250: 250 Volts AC; R600: 600 Volts AC R60030-1SR Cable Ties Wire Ampere Ratings: 0.10 - 600 Amps Bulk Multi-conductor Cables Short-circuit current Rating: 200,000 RMS Symmetrical Amps Wire Management Products Power Supplies R250 Series Fuse Blocks (250V) 0.1 to 30 31 to 60 61 to 100 Maximum Fig # Pcs/ Wt. Price Wire Size Pkg (lbs.) 1 1 0.10 $8.00 2 #10-18 Cu 2 0.25 $12.50 3 3 0.30 $18.50 1 4 0.23 $14.50 5 0.44 $25.00 2 #2-14 Cu #2-8 Al 3 6 0.45 $34.50 1 7 0.60 $36.00 2 1/0-8 Cu-Al 8 1.00 $60.00 3 9 1 1.50 $79.00 1 250MCM-6 101 to 200 3 Cu-Al 2.20 $90.00 5.30 $270.00 1 500MCM-4 201 to 400 3 Cu-Al 2.90 $247.00 1070 $737.00 5.80 $300.00 20.70 $969.00 See Table 1 below then refer to 1 (2) 500MCM- Figure # 401 to 600 3 4/ 0 Cu-Al Part Number Amps R60030-1SR R60030-2SR R60030-3SR R60060-1CR R60060-2CR R60060-3CR R60100-1CR R60100-2CR R60100-3CR R60200-1CR R60200-3CR R60400-1CR R60400-3CR* R60600-1CR R60600-3CR* * Not UL, Please use (3) J60600-1CR to assemble a 3 pole UL Fuseblock Poles R25030-1SR R25030-2SR R25030-3SR R25060-1CR R25060-2CR R25060-3CR R25100-1CR R25100-2CR R25100-3CR R25200-1CR R25200-3CR R25400-1CR R25400-3CR* R25600-1CR R25600-3CR* Poles Part Number Amps R600 Series Fuse Blocks (600V) Maximum Fig # Wire Size 1 0.1 to 30 2 #10-18 Cu only 3 1 31 to 60 61 to 100 2 #2-14 Cu #2-8 Al 3 DC Converters Pcs/ Wt. Price Pkg (lbs.) 13 0.24 $17.50 14 0.44 $26.50 15 0.40 $31.00 16 0.30 $20.50 17 0.60 $34.50 18 0.85 $44.00 1 19 1.00 $44.00 2 1/0-8 Cu-Al 20 1.50 $64.00 3 21 2.30 Retired 0.50 $91.00 4.95 $258.00 4.10 $219.00 9.85 $617.00 7.50 $348.00 17.30 $929.00 101 to 200 1 250MCM-6 3 Cu-Al 201 to 400 1 500MCM-4 3 Cu-Al 401 to 600 1 (2) 500MCM3 4/0 Cu-Al See Table 2 below then refer to Figure # 1 * Not UL, Please use (3) J60600-1CR to assemble a 3 pole UL Fuseblock Book 3 (14.3) w w w. a u t o m a t i o n d i r e c t . c o m / c i r c u i t- p r o t e c t i o n Circuit Protection eCP-187 Transformers and Filters Circuit Protection Tools Test Equipment Enclosures Enclosure Climate Control Safety: Electrical Components Safety: Protective Wear Terms and Conditions Prices as of April 27, 2016. Check Web site for most current prices. R250 Fuse Blocks for Class RK Fuses Dimensions inches (mm) 250V, 0.1 Amp to 30 Amp 1.41 [35.8] 0.22 [5.6] 1.09 [27.7] 0.17 [4.4] 0.75 0.41 [19.1] [10.4] 2.05 [52.1] 1.25 [31.8] 0.95 [24.1] 3 [76.2] 2.5 [63.5] 2 SPACES AT 0.95 - 1.91 [24.1 - 48.5] 0.25 [6.4] 1.27 [32.3] 3.03 [77] 0.5 [12.7] 1.52 [38.6] 0.22 DIAMETER [5.6] Figure 1 0.55 [14] 0.55 [14] Figure 2 Figure 3 250V, 31 Amp to 60 Amp 1.73 [44] 0.27 [6.9] K 4.125 [104.8] 2.81 [71.4] 1.5 [38.1] 0.5 [12.7] 0.5 [12.7] 1.94 [49.3] 0.5 [12.7] 0.5 [12.7] 1.94 [49.3] 1.94 [49.3] 0.22 x 0.41 [5.6 x 10.4] (dia. x c bore) 0.22 x 0.41 [5.6 x 10.4] (dia. x c bore) 0.22 x 0.41 [5.6 x 10.4] (dia. x c bore) 1.25 [31.8] 4.25 [108] 1.5 [38.1] Figure 4 Figure 5 1.81" to 100 0.59" 250V, 61 Amp Amp 2.06" 0.25" 2.06 [52.3] 0.25 [6.4] 7.36" 0.62" 1.81 [46] 0.62 [15.7] 0.59 [15] 3.38" 1.56" 0.62" 3.38 [85.9] 1.56 [39.6] 0.62 [15.7] Figure 6 4.94" 1.56" 1.56" 0.59" 0.62" 4.94 [125.5] 0.59 [15] 0.62 [15.7] 1.56 [39.6] 0.28" DIA. x 0.5" C'BORE 1.56 [39.6] 2.38" 3.125" 0.28" DIA. x 0.5" C'BORE [7.1 x 12.7] 2.125" 7.36 [187] 2.38 [60.5] 3.125 [79.4] 2.125 [54] Figure 7 Figure 8 Figure 9 Note: All dimensions shown in inches [mm] Book 3 (14.3) eCP-188 Circuit Protection 1 - 8 0 0 - 633 - 0 4 0 5 Prices as of April 27, 2016. Check Web site for most current prices. R250 Fuse Blocks for Class RK Fuses Company Information Terminal Blocks Power Distribution Blocks Table 1 (250V) Fig # R25200-1CR 10 R25200-3CR 11 R25400-1CR 10 R25400-3CR 12 R25600-1CR 10 R25600-3CR 12 A B C D E F G H Wiring Accessories K 7.15in 3.15in (181.6mm) (80mm) 3.0in (76.2mm) 2.06in 0.5in 2.0in 3.0in 0.75in 0.31in (52.3mm) (12.7mm) (50.8mm) (76.2mm) (19.05mm) (7.9mm) 9.06in (230.1mm) 9.06in (230.1mm) 11.0in (279.4mm) 11.0in (279.4mm) 3.0in (76.2mm) 4.0in (101.6mm) 3.0in (76.2mm) 5.0in (127mm) 3.02in (76.7mm) 2.5in (63.5mm) 4.0in (101.6mm) 3.0in (76.2mm) ZIPLink Connection System Dimenions on Figure 4.0in (101.6mm) 4.0in (101.6mm) 4.97in (126.2mm) 4.97in (126.2mm) 0.91in (23.1mm) 0.82in (20.8mm) 1.125in (28.6mm) 1.87in (47.5mm) 1.75in (44.5mm) 9.25in (235mm) 1.75in (44.5mm) 11.0in (279.4mm) 3.0in (76.2mm) 10.88in (276.4mm) 4.0in (101.6mm) 14.74in (374.4mm) 1.0in (25.4mm) 1.0in (25.4mm) 1.0in (25.4mm) 1.0in (25.4mm) Multi-wire Connectors 0.31in (7.9mm) 0.56in (14.2mm) 0.56in (14.2mm) 0.56in (14.2mm) Sensor Cables and Connectors M12 Junction Blocks Panel Interface Connectors 250V, 101 Amp to 200 Amp Wiring Duct 8 [203.2] 6 [152.4] B H K G F E .5 [12.7] Bulk Multi-conductor Cables 2 [50.8] .34 [8.6] DIA. HOLE THROUGH 0.34 [8.6] DIAMETER 0.75 [19.1] C'BORE C A Wire 5 [127] 3 [76.2] 3.4 [86.4] 1 [25.4] Cable Ties 4.5 [114.3] 7.13 [181.1] EYELETS TO ACCEPT .25 [6.35] DIA. SCREW Wire Management Products 3 [76.2] Power Supplies DC Converters D 2.06 [52.3] Transformers and Filters 9 [228.6] Figure 10 Circuit Protection Figure 11 Tools Test Equipment 250V, 201 Amp to 600 Amp Enclosures Enclosure Climate Control G B F E H Safety: Electrical Components Safety: Protective Wear A C .34 [8.6] DIA. HOLE THROUGH Terms and Conditions D Figure 12 Note: All dimensions shown in inches [mm] Book 3 (14.3) w w w. a u t o m a t i o n d i r e c t . c o m / c i r c u i t- p r o t e c t i o n Circuit Protection eCP-189 Prices as of April 27, 2016. Check Web site for most current prices. R600 Fuse Blocks for Class RK Fuses Dimensions inches (mm) 600V, 0.1 Amp to 30 Amp 1.73 [43.9] 0.26 1.73 [6.6] 1.54 [39.1] 0.62 [15.7] [43.9] 0.26 [6.6] 0.25 [6.4] 1.54 [39.1] [39.6] 0.62 [15.7] 0.25 [6.4] 0.62 [15.7] 0.28x0.5 [7.1 x 12.7] 0.25 [6.4] 1.56 [39.6] 0.62 0.25 [15.7] [6.4] 1.564.25 [39.6] [108] 1.56 [39.6] 1.56 [39.6] 0.62 [15.7] 0.28x0.5 [7.1 x 12.7] 0.28x0.5 [7.1 x 12.7] 0.28x0.5 [7.1 x 12.7] 0.28x0.5 [7.1 x 12.7] 6.25 [158.8] 4.25 [108] 2.90 [73.7] 1.562.90 [39.6] [73.7] 0.62 1.56 [15.7] 0.28x0.5 [7.1 x 12.7] 3.13 [79.5] 3.13 [79.5] 6.25 [158.8] 1.56 [39.6] Figure 13 2.06 [52.3] 0.25 [6.4] Figure 3.38 14 [85.9] 1.56 [39.6] 0.62 3.38 [15.7] 1.81 [46] 600V, 31 Amp to 60 Amp 0.59 0.62 [15.7] 2.06 [52.3] 0.25 [6.4] [15] 1.81 [46] [85.9] 1.56 [39.6] 0.62 [15.7] 0.59 [15] 0.62 [15.7] 1.56 [39.6] Figure 4.94 15 [125.5] 1.56 1.56 [39.6] [39.6] 0.59 [15] 0.62 [15.7] 4.94 [125.5] 1.56 1.56 0.28" DIA. x 0.5" C'BORE [39.6] [39.6] 0.59 [15] [7.1 x 12.7] 0.62 [15.7] 0.28" DIA. x 0.5" C'BORE 7.36 [187] 2.38 [60.5] 7.36 [187] 3.125 [7.1 x 12.7] [79.4] 2.38 2.125 [54][60.5] 2.22 [56.4] 2.38 [60.5] 0.34 [8.6] 2.38 [60.5] 0.34 [8.6] 0.88 Figure 16[22.4] 2.22 [56.4] 0.28x0.5 Figure 17 [7.1 100 x 12.7] Amp 600V, 61 Amp to 0.67 2.38 [60.5] 0.69 [17.4] 9.5 [241.3] 0.67 [17] 0.88 [22.4] 0.88 [22.4] 2.22 [56.4] 0.88 4.03 [102.4] 1.81 [46] [17] 0.88 [22.4] 0.28x0.5 [22.4] [7.1 x 12.7] 4.03 [102.4] 0.28x0.5 1.81 [7.1 x 12.7] 4.03 [46] [102.4] 0.67 1.81 [17] [46] 0.88 0.28x0.5 [22.4] [7.1 x 12.7] 0.28x0.5 [7.1 x 12.7] 9.5 [241.3] 0.67 [17] 0.88 [22.4] 1.81 [46] 5.84 [148] 1.81 [46] 3.125 [79.4] 2.125 [54] Figure 18 5.84 [148] 0.28x0.5 1.81 1.81 [7.1 x 12.7] 0.67 [46] [46] 5.84 [17] [148] 0.88 0.67 1.81 [22.4] [17] [46] 0.88 4.25 [108] 0.28x0.5 [22.4] [7.1 x 12.7] 0.28x0.5 [7.1 x 12.7] 0.28x0.5 [7.1 x 12.7] 2.63 [67] 4.25 [108] 9.5 [241.3] 4.25 [108] 2.63 [67] 2.63 [67] Figure 19 Figure 20 Figure 21 Note: All dimensions shown in inches [mm] Book 3 (14.3) eCP-190 Circuit Protection 1 - 8 0 0 - 633 - 0 4 0 5 Prices as of April 27, 2016. Check Web site for most current prices. R600 Fuse Blocks for Class RK Fuses Company Information Terminal Blocks Power Distribution Blocks Table 2 (600V) Fig # A B C D E F G H Wiring Accessories K R60200-1CR 22 9.63in 3.09in 3.0in 3.31in 0.5in 2.0in 3.0in 0.75in 0.31in (244.6mm) (78.5mm) (76.2mm) (84.1mm) (12.7mm) (50.8mm) (76.2mm) (19.1mm) (7.9mm) R60200-3CR 23 Dimensions on Figure R60400-1CR 22 12.0in 4.0in 3.0in 4.5in 0.63in (305mm) (102mm) (76.2mm) (114.3mm) (16mm) R60400-3CR 24 Dimensions on Figure R60600-1CR 22 14.0in 4.97in 3.0in 5.5in 1.125in 1.75in 4.0in 1.0in 0.56in (356mm) (126.2mm) (76.2mm) (140mm) (28.6mm) (44.5mm) (102mm) (25.4mm) (14.2mm) R60600-3CR 25 Dimensions on Figure 250V, to600 600A; 600V, 101101A Amp to Amp B H K Sensor Cables and Connectors M12 Junction Blocks Panel Interface Connectors Wiring Duct 9.0 [229] 8.0 [203.2] 6.5 [165] Cable Ties 3.15 [80] Bulk Multi-conductor Cables Wire Management Products 9.58 [243.3] 0.34 [8.6] DIAMETER 0.75 [19.1] DIA. C'BORE .50 [12.7] Deep C A Wire .75 [19.1] 0.34 DIAMETER 0.75" C'BORE Multi-wire Connectors 1.75in 3.0in 1.0in 0.56in (44.5mm) (76.2mm) (25.4mm) (14.2mm) 600V, 101A to 600A 600V, 101 Amp to 200 Amp G F E ZIPLink Connection System 5.5 3.0 [140] [76.2] Power Supplies DC Converters D Transformers and Filters 2.04 [52] FIGURE 10. Figure 22 Circuit Protection Tools Figure 23 Test Equipment Enclosures 1.19 [30.2] 15.26 [387.6] 4.02 [102.1] 11.63 [295.4] 9.25 [235] 1.00 [25.4] 0.34 [8.6] DIAMETER 0.75 [19.1] DIA. C'BORE .67 [17] Deep 12.00 [304.8] Enclosure Climate Control 600V, 401 Amp to 600 Amp 600V, 201 Amp to 400 Amp 2.13 [54.1] 0.34 [8.6] DIAMETER 0.75 [19.1] DIA. C'BORE .67 [17] Deep 7.00 [178] 2.5 [63.5] Figure 24 4.987 [127] 11.0 [279.4] 1.00 [25.4] 8.00 [203.2] 3.00 [76.2] Figure 25 Book 3 (14.3) Circuit Protection Safety: Protective Wear Terms and Conditions 14.00 [356] Note: All dimensions shown in inches [mm] w w w. a u t o m a t i o n d i r e c t . c o m / c i r c u i t- p r o t e c t i o n Safety: Electrical Components eCP-191 Prices as of April 27, 2016. Check Web site for most current prices. Accessories Accessories Part Number Description FP-2 Fuse puller for fuse dia. 13/32” - 13/16”. Fuse type: 0-60A, 250V; 0-30A, 600V Multi-pole connection kit to connect new design multiple Class CC and Midget Class fuse holders together. Kit consists of 6 connectors and 3 handle pins to connect up to 4 fuse holders. JV-L* (Not Field Installable) Pcs/Pkg Price 1 $16.50 $6.50 Note: Will not work with retired design fuse holders shipped before November 1, 2009. *Roll pin punch or installation tool is required to install handle pins (Tool not sold by Automationdirect.com). FP2 Handle Pin Dimensions Diameter = 0.0625 in [1.58 mm] Length = 0.632 in [16.07 mm] JV-L JV-L Book 3 (14.3) eCP-218 Circuit Protection 1 - 8 0 0 - 633 - 0 4 0 5 Prices as of April 27, 2016. Check Web site for most current prices. Cross Reference Guide Company Information Terminal Blocks Power Distribution Blocks CROSS REFERENCE GUIDE By manufacturers type reference or series number. Ampere ratings must be added for ordering purposes. FUSE TYPE VOLT EDISON BRUSH/ BUSSMANN MERSEN / GEC/CEFCO LITTELFUSE DORMAN GOULD UL CLASS CURRENT LIMITING FUSES (CSA CLASS) CC (HRCI-CC) RK1 RK5 J T Time-Delay 600 EDCC – LP-CC ATDR – CCMR Time-Delay 600 HCTR – FNQ-R ATQR – KLDR Fast-Acting 600 HCLR HCLR KTK-R ATMR CTK-R KLKR 250 LENRK – LPN-RK-SP A2DR – LLNRK 600 LESRK – LPS-RK-SP A6DR – LLSRK 250 ECNR – FRN-R TR – FLNR 600 Time-Delay Dual Element Time-Delay Dual Element ECSR – FRS-R TRS – FLSR Time-Delay Dual Element 600 JDL – LPJ AJT – JTD High-Speed AC Drive 600 JHL – DFJ HSJ – – 300 TJN – JJN A3T – JLLN 600 TJS – JJS A6T – JLLS Extremely Fast-Acting Sensor Cables and Connectors M12 Junction Blocks Panel Interface Connectors Wiring Duct Cable Ties Wire 600 MCL MCL KTK ATM CTK KLK 250 MOL MOL BAF/BAN OTM – BLF 500 MEQ MEQ FNQ ATQ – FLQ 250 MEN MEN FNM TRM – FLM 250/125 ABC ABC ABC GAB – 314 250/32 AGC AGC AGC GGC – 312 250 MDA MDA MDA – – 326 250/32 MDL MDL MDL GDL – 313 Fast-Acting 250/125 GMA GMA GMA GGM – 235 Medium Time-Delay 250/125 GMC GMC GMC GSC – – Fast-Acting 250 S500 BDB GDB GSB – 217 Time-Delay 250 S506 BDC GDC GDG – 218 FP-2 – – – Midget Time-Delay 1/4”x 1-1/4” Ceramic 1/4”x 1-1/4” Glass 1/4”x 1-1/4” Ceramic 1/4”x 1-1/4” Glass 5x20 mm Glass 5x20 mm Glass Fast-Acting Time-Delay Bulk Multi-conductor Cables Wire Management Products Power Supplies DC Converters Transformers and Filters Circuit Protection Tools Fuse Puller Fuse Puller FP-2 – old - 38072 – new - FP-2 ZIPLink Connection System Multi-wire Connectors UL CLASS GENERAL PURPOSE FUSES Fast-Acting Wiring Accessories Test Equipment Enclosures Enclosure Climate Control Safety: Electrical Components Safety: Protective Wear Terms and Conditions Book 3 (14.3) w w w. a u t o m a t i o n d i r e c t . c o m / c i r c u i t- p r o t e c t i o n Circuit Protection eCP-219