www.oez.com VJ1-2012-A Any changes reserved Arion Air circuit breakers OEZ s.r.o. Šedivská 339 561 51 Letohrad Czech Republic tel.: +420 465 672 111 +420 465 672 101 fax: +420 465 672 398 +420 465 672 151 e-mail: oeztrade.cz@oez.com www.oez.com www.oez.com Air circuit breakers Arion CONTENT – Commercial information DATA FOR SELECTION OF CIRCUIT BREAKERS AND SWITCH-DISCONNECTORS .................................................2 ADVANTAGES OF CIRCUIT BREAKERS ARION .............................................................................................................5 OVERVIEW OF TYPES AND ACCESSORIES ....................................................................................................................6 DATA FOR SELECTION OF OVERCURRENT RELEASE ..................................................................................................9 MEANING OF TYPE DESIGNATION POSITIONS.........................................................................................................10 STANDARD EQUIPMENT OF CIRCUIT BREAKER/SWITCH-DISCONNECTOR .......................................................10 QUICK COMPOSITION OF TYPE DESIGNATION .........................................................................................................11 PROCEDURE IN COMPOSITION OF TYPE DESIGNATION ........................................................................................12 COMPOSITION OF TYPE DESIGNATION 3-pole circuit breakers, switch-disconnectors for AC operation Fixed design ................................................................................................................................................................14 Withdrawable design..................................................................................................................................................16 COMPOSITION OF TYPE DESIGNATION 4-pole circuit breakers, switch-disconnectors for AC operation Fixed design ................................................................................................................................................................18 Withdrawable design..................................................................................................................................................20 COMPOSITION OF TYPE DESIGNATION 3 and 4-pole switch-disconnectors for DC operation Fixed design ................................................................................................................................................................22 Withdrawable design..................................................................................................................................................23 BASIC ACCESSORIES - drives, auxiliary releases and switches.................................................................................24 ADDITIONAL ACCESSORIES Method of connection, auxiliary circuit terminal blocks ..............................................................................................25 Closing release and motor drives with different operating voltage, shunt trips ..........................................................26 Rated voltage 1000/1150 V.........................................................................................................................................27 Rated current modules................................................................................................................................................27 Signal switches ...........................................................................................................................................................27 Control presentation ...................................................................................................................................................28 Data communication and measuring ..........................................................................................................................28 Blocking and locking ...................................................................................................................................................29 Covers, door sealing frame ..........................................................................................................................................30 SEPARATELY DELIVERED ACCESSORIES Connecting sets - fixed design ....................................................................................................................................31 Connecting sets - withdrawable design ......................................................................................................................32 Rated current modules ...............................................................................................................................................35 Test device ..................................................................................................................................................................35 CubicleBUS modules ...................................................................................................................................................35 Voltage sources ...........................................................................................................................................................35 Data communication device and measuring function .................................................................................................36 Measuring voltage transformers .................................................................................................................................36 External measuring current transformers for N conductor ..........................................................................................36 Auxiliary power sources for shunt trip .........................................................................................................................37 Bowden cables for mechanical blocking .....................................................................................................................37 Sealable covers of overcurrent release ........................................................................................................................37 Door sealing frames ....................................................................................................................................................37 Transparent covers ......................................................................................................................................................37 Arc chute covers ..........................................................................................................................................................37 Bearing angles ............................................................................................................................................................37 ACCESSORIES – FOR ADDITIONAL INSTALLATION BY OEZ SERVICE....................................................................38 CONTENT – Technical information see page 45 1 Arion Commercial information DATA FOR SELECTION OF CIRCUIT BREAKERS for AC operation Size Rated current In I 630 A 800 A 1000 A 1250 A 1600 A 2000 A Rated operating voltage Ue 690 V a.c. Rated frequency Rated short-circuit ultimate breaking capacity fn Icu Rated short-time withstand current Icw Rated short-circuit making capacity Icm 50/60 Hz N - 55 kA/415 V a.c. S - 66 kA/415 V a.c. H - 85 kA/415 V a.c. N - 42 kA /1 s S - 50 kA/1 s H - 66 kA/1 s N - 121 kA/415 V a.c. S - 145 kA/415 V a.c. H - 187 kA/415 V a.c. 3, 4 Number of poles II 800 A 1000 A 1250 A 1600 A 2000 A 2500 A 3200 A 4000 A 690 V a.c. (1000 V a.c./1150 V a.c.) 50/60 Hz N - 66 kA/415 V a.c. S - 80 kA/415 V a.c. H - 100 kA/415 V a.c. N - 55 kA /1 s S - 66 kA /1 s H - 80 kA /1 s N - 145 kA/415 V a.c. S - 176 kA/415 V a.c. H - 220 kA/415 V a.c. 3, 4 Max. rated current of the circuit breaker In [A] Rated short-circuit ultimate breaking capacity III 4000 A 5000 A 6300 A 690 V a.c. (1000 V a.c./1150 V a.c.) 50/60 Hz H - 100 kA/415 V a.c. C - 150 kA (3-pole),130 kA (4-pole) /415 V a.c. H - 100 kA /1 s C - 100 kA /1 s H - 220 kA/415 V a.c. C - 330 kA (3-pole), 286 kA (4-pole)/415 V a.c. 3, 4 Dimensions Icu at 415 V [kA] a.c. fixed 3/4-pole withdrawable 3/4-pole 291 / 291 385 / 385 depth 440.5/440.5 468.5/468.5 height 320 / 410 320 / 410 width 291 / 291 385 / 385 depth 440.5/440.5 468.5/468.5 height 460 / 590 460 / 590 width 291 / 291 385 / 385 depth 440,5/440,5 468,5/468,5 height 704 / 914 704 / 914 width 630 Size I 800 1000 1250 1600 N S H 55 66 85 2000 800 1000 Size II 1250 1600 2000 2500 N S H 66 80 100 3200 4000 Size III 4000 5000 H 100 6300 2 C 150 - 3-pole 130 - 4-pole Commercial information Arion DATA FOR SELECTION OF SWITCH-DISCONNECTOR for AC operation Size Rated current In Rated operating voltage Ue 690 V a.c. Rated frequency Rated short-circuit making capacity fn Icm Rated short-time withstand current Icw 50/60 Hz N - 105 kA/415 V a.c. S - 143 kA/415 V a.c. H - 187 kA/415 V a.c. N - 42 kA /1 s S - 50 kA/1 s H - 66 kA/1 s 3, 4 Number of poles I 630 A 800 A 1000 A 1250 A 1600 A 2000 A II 800 A 1000 A 1250 A 1600 A 2000 A 2500 A 3200 A 4000 A 690 V a.c. (1000 V a.c./1150 V a.c.) 50/60 Hz N - 121 kA/415 V a.c. S - 176 kA/415 V a.c. H - 220 kA/415 V a.c. N - 55 kA /1 s S - 66 kA /1 s H - 80 kA /1 s 3, 4 III 4000 A 5000 A 6300 A 690 V a.c. (1000 V a.c./1150 V a.c.) 50/60 Hz H - 220 kA/415 V a.c. C - 150 kA (3-pole),130 kA (4-pole) /415 V a.c. H - 100 kA /1 s C -100 kA / 1 s 3, 4 DATA FOR SELECTION OF SWITCH-DISCONNECTOR for DC operation Size Rated current In Rated operating voltage Ue Rated conditional short-circuit current Icc Rated short-time withstand current Icw Rated short-circuit making capacity Icm Number of poles II 1000 A 2000 A 4000 A 300 V d.c. 600 V d.c. 1000 V d.c. 30 kA/300 V d.c. 25 kA/600 V d.c. 20 kA/1000 V d.c. 30 kA /1 s 25 kA /1 s 20 kA /1 s 30 kA/300 V d.c. 25 kA/600 V d.c. 20 kA/1000 V d.c. 3, 4 For possible protection of DC circuits, please call technical assistance. See the cover sheet for contact. 3 Arion NOTES 4 Commercial information Commercial information Arion NOTES 5 Arion Commercial information OVERVIEW OF TYPES AND ACCESSORIES 1 Withdrawable device 2 Front, flanged, horizontal and vertical connection 3 Position signal switches 4 Earthing contact 2 5 Insulation cover 6 COM 15 module PROFIBUS 7 Cubicle BUS modules 8 Closing release / shunt trip, undervoltage release 9 Connector and terminal blocks of auxiliary circuits 10 Auxiliary switches 1 11 Door sealing frame 3 12 Protective caps for mechanical ON/OFF 4 13 Emergency OFF push-button 14 Locking device against unauthorized closing 15 Motor drive 16 Counter of cycles 17 BSS module 18 Overcurrent release 19 Remote reset electromagnet 21 19 20 BDA adapter 21 Display 22 Earth fault module 23 Rated current module 24 Measuring function module 22 25 Air circuit breaker Arion 18 23 24 20 6 Arion Commercial information OVERVIEW OF TYPES AND ACCESSORIES 7 6 8 5 9 11 25 10 12 17 13 14 15 16 7 Arion NOTES 8 Commercial information Arion Commercial information DATA FOR SELECTION OF OVERCURRENT RELEASE Rating Plug IR I sd t sd Overcurrent release name Overload protection Short-time delayed short-circuit protection Instantaneous short-circuit protection Neutral conductor protection Earth fault protection Additional functions Neutral conductor protection ON/OFF Short-time delayed short-circuit protection ON/OFF Instantaneous short-circuit protection ON/OFF Thermal memory ON/OFF Load guarding Short-time delayed short-circuit protection switchable to I2t Instantaneous short-circuit protection adjustable Overload protection switchable to I4t Overload protection ON/OFF Adjustable neutral conductor protection N Switchable parameter sets Parameterization and display Parameterization by rotary switches (10 positions) Parameterization by means of communication (absolute values) Parameterization by means of menu (absolute values) Remote parameterization of basic functions Remote parameterization of additional functions 4-line LCD Graphic LCD Measuring function Measuring function Plus Communication CubicleBUS PROFIBUS-DP/MODBUS Ethernet + YES, – NO, z optional L S I N G ETU15B + – + – – ETU25B + + + – – ETU27B + + + + + ETU45B + + + + ETU76B + + + + z z – – – – – – – – – – +/+ – – – – +/+ +/+ +/+ + + +/+ +/+ +/+ + + – – – + + + – – – – – – – – – – – – – – + + – + – + + + + + + + + + – – – – – + – – – – – – – – – – – – – – – – – + – + + + – + – – – z z – – – – – – – – – + + z z z z z 9 Arion Commercial information MEANING OF TYPE DESIGNATION POSITIONS Example of type designation: ARION WL1220-3CB36-4GA2-Z K07 Position number: Rated current Overcurrent release Design and type of connection Auxiliary switches Accessories (it is possible to fill in more codes at a time) 14 15 16 20 - 3 CB 3 6 - 4 G A 2 - Z K07 2nd auxiliary release 13 Drive 12 Number of poles 11 9 - 10 8 Rated short-circuit ultimate breaking capacity 1st auxiliary release 6-7 ARION WL1 2 Type designation: Size 5 13) hand and motor drive with closing release for 230 V a.c./220 V d.c. 14) shunt trip 230 V a.c./220 V d.c. 15) without 2nd auxiliary release 16) 2NO + 2NC auxiliary contacts Accessory code - signal switch „switched off by overcurrent release“ - K07 STANDARD EQUIPMENT OF CIRCUIT BREAKER/SWITCH-DISCONNECTOR Each circuit breaker/switch-disconnector has the following standard equipment 10 ARION WL1220-3CB36-4GA2-Z K07 Fixed design Push-button for mechanical ON Push-button for mechanical OFF Hand drive with storage device Mechanical indicator of circuit breaker state - ON/OFF state Mechanical storage device state - wound up/released Mechanical indicator „ready-to-close“ Auxiliary switches - 2NO + 2NC contacts Terminal blocks and connectors for connection of auxiliary circuits - the circuit breaker/switch-disconnector is always equipped with all necessary terminal blocks and connectors; terminal block has screw terminals Mechanical indicator of switching off by overcurrent release Mechanical interlocking of reset after switching off by overcurrent release Parameters and description of circuit breaker according to positions: 5) size II 6 - 7) rated current In = 2000 A 8) rated short-circuit ultimate breaking capacity Icu = 80 kA 9 - 10) overcurrent release ETU25B 11) 3-pole design 12) withdrawable design, rear horizontal connection Withdrawable design - withdrawable design contains additionally: Mechanical indicator of the circuit breaker position in the withdrawable device Locking device against shifting of circuit breaker using a padlock Arion Commercial information QUICK COMPOSITION OF TYPE DESIGNATION The table can be used for quick and simple selection and composition of type designation of a circuit breaker/switch-disconnector Arion. The table contains only common types of circuit breakers/switch-disconnectors. For an exhaustive offer see the following pages of the catalogue. Type designation ARION WL1 Size size I from 630 to 2000 A 1 size II from 800 to 4000 A 2 size III from 4000 to 6300 A 3 Rated current 630 A size I 06 800 A size I, II 08 1000 A size I, II 10 1250 A size I, II 12 1600 A size I, II 16 2000 A size I, II 20 2500 A size II 25 3200 A size II 32 4000 A size II, III 40 5000 A size III 50 6300 A size III 63 Rated short-circuit ultimate breaking capacity N – ECO 55 kA for size I, 66 kA for size II 2 S – STANDARD 66 kA for size I, 80 kA for size II 3 H – HIGH 85 kA for size I, 100 kA for size II and size III 4 C – EXTRA 150 kA for size III (3-pole), 130 kA for size III (4-pole) 5 Overcurrent release without overcurrent release switch-disconnector AA ETU25B circuit breaker CB ETU45B - without display circuit breaker EB ETU45B - with display circuit breaker FB ETU76B - with graphic display circuit breaker NB Design 3-pole 3 4-pole 4 Design fixed rear vertical connection 1 fixed rear horizontal connection 2 fixed front connection 4 withdrawable rear horizontal connection 6 withdrawable rear vertical connection 7 Drive hand drive 1 4 hand and motor drive, closing release 230 V a.c./220 V d.c. hand and motor drive, closing release 110 V a.c./d.c. 5 hand and motor drive, closing release 24 V d.c. 6 1st auxiliary release without 1st auxiliary release A shunt trip 24 V d.c. B shunt trip 110 V a.c./d.c. F shunt trip 230 V a.c./220 V d.c. G 2nd auxiliary release without 2nd auxiliary release A shunt trip 24 V d.c. B shunt trip 110 V a.c./d.c. F shunt trip 230 V a.c./220 V d.c. G undervoltage release 24 V d.c. J undervoltage release 110 V a.c./d.c. M undervoltage release 230 V a.c./220 V d.c. N Auxiliary switches 2 NO + 2 NC 2 4 NO + 4 NC 4 Accessories (it is possible to fill in more codes at a time separated by positive sign +) electrical ON push-button on the front panel C11 signal switch of the storage device state C20 signal switch „ready-to-close” C22 signal switch „switched off by release“ K07 position signal switches in the withdrawable device R15 door sealing frame T40 locking device against unauthorized closing on the front control panel S01 1 20 - 3 CB 3 6 - 4 G A 2 -Z K07 Example of type designation: ARION WL1120-3CB36-4GA2-Z K07 11 Arion Commercial information PROCEDURE IN COMPOSITION OF TYPE DESIGNATION Steps for correct composition For correct composition of type designation, follow the following steps. As described and illustrated on the example. 1. Determination of circuit breaker type in the catalogue content - 3 or 4-pole circuit breaker/switch-disconnector for AC or DC application of fixed or withdrawable design 2. Determination of the type designation basis according to - connection type - rated current - rated ultimate short-circuit breaking capacity 3. Determination of overcurrent release - for selection it is possible to use detailed table on page 9 „Data for selection of overcurrent release“ 4. Selection of basic accessories - drives, auxiliary releases and switches 5. Selection of additional accessories It is also possible to order separately delivered accessories for the circuit breakers. Steps 1 - 4 are mandatory for the composition of complete type designation for ordering. Step 5 depends on other requirements for the circuit breaker. Example of type designation composition 1. Determination of the circuit breaker/switch-disconnector type in the catalogue content Catalogue content 2. Determination of the type designation basis according to: Page 1 - connection type - rated current - rated ultimate short-circuit breaking capacity Type designation basis: ARION WL 1220-232- Page 14 3. Determination of overcurrent release Type designation including overcurrent release: ARION WL1220-2CB32- 12 Page 14 Commercial information Arion PROCEDURE IN COMPOSITION OF TYPE DESIGNATION 4. Selection of basic accessories Type designation: ARION WL 1220-2CB32-4GA2 Page 24 5. Selection of additional accessories Complete type designation: ARION WL 1220-2CB32-4GA2-Z K07 Page 27 13 Arion Commercial information 3P COMPOSITION OF TYPE DESIGNATION Fixed design, 3-pole, AC Rated current In 1) [A] Rear horizontal connections 630 800 1000 1250 1600 2000 2500 3200 4000 5000 6300 Rated short-circuit ultimate breaking capacity Icu /440 V 66 kA – size II 66 kA – size I N S ARION WL1106-332- ARION WL1108-332- ARION WL1110-332- ARION WL1112-332- ARION WL1116-332- ARION WL1220-232- ARION WL1120-332- ARION WL1225-232- ARION WL1232-232- - 80 kA – size II S ARION WL1208-332- ARION WL1210-332- ARION WL1212-332- ARION WL1216-332- ARION WL1220-332- ARION WL1225-332- ARION WL1232-332- - 630 800 1000 1250 1600 2000 2500 3200 4000 5000 6300 ARION WL1106-231- ARION WL1108-231- ARION WL1110-231- ARION WL1112-231- ARION WL1116-231- ARION WL1120-231- - ARION WL1220-231- ARION WL1225-231- ARION WL1232-231- ARION WL1240-231- - ARION WL1106-331- ARION WL1108-331- ARION WL1110-331- ARION WL1112-331- ARION WL1116-331- ARION WL1120-331- - ARION WL1208-331- ARION WL1210-331- ARION WL1212-331- ARION WL1216-331- ARION WL1220-331- ARION WL1225-331- ARION WL1232-331- ARION WL1240-331- - Front connections one series of holes 630 800 1000 1250 1600 2000 2500 3200 4000 5000 6300 ARION WL1106-233- ARION WL1108-233- ARION WL1110-233- ARION WL1112-233- ARION WL1116-233- - ARION WL1220-233- ARION WL1225-233- ARION WL1232-233- - ARION WL1106-333- ARION WL1108-333- ARION WL1110-333- ARION WL1112-333- ARION WL1116-333- - ARION WL1208-333- ARION WL1210-333- ARION WL1212-333- ARION WL1216-333- ARION WL1220-333- ARION WL1225-333- ARION WL1232-333- - Front connections two series of holes 630 800 1000 1250 1600 2000 2500 3200 4000 5000 6300 ARION WL1106-234- ARION WL1108-234- ARION WL1110-234- ARION WL1112-234- ARION WL1116-234- ARION WL1120-234- - ARION WL1220-234- ARION WL1225-234- ARION WL1232-234- - ARION WL1106-334- ARION WL1108-334- ARION WL1110-334- ARION WL1112-334- ARION WL1116-334- ARION WL1120-334- - ARION WL1208-334- ARION WL1210-334- ARION WL1212-334- ARION WL1216-334- ARION WL1220-334- ARION WL1225-334- ARION WL1232-334- - NSE00967 55 kA – size I N ARION WL1106-232- ARION WL1108-232- ARION WL1110-232- ARION WL1112-232- ARION WL1116-232- ARION WL1120-232- - NSE00969 NSE00968 NSE00979 Rear vertical connections Switch-disconnector unit (switch-disconnector) 2) AA Overcurrent release - without earth fault protection (circuit breaker) Overcurrent release ETU15B – protective functions LI 4) Overcurrent release ETU25B – protective functions LSI Overcurrent release ETU45B – protective functions LSIN 3) Overcurrent release ETU45B – protective functions LSIN, with display, number of lines 4 3) Overcurrent release ETU76B – protective functions LSIN, graphic display 3) BB CB EB FB NB Overcurrent release - without earth fault protection (circuit breaker) Overcurrent release ETU27B – protective functions LSING 3) Overcurrent release ETU45B – protective functions LSING 3) Overcurrent release ETU45B – protective functions LSING, with display, number of lines 4 3) Overcurrent release ETU76B – protective functions LSING, graphic display 3) DG EG FG NG 1) 1 A A 2 Standard type designation Hand drive with mechanical closing Auxiliary switches: contacts 2200 (2NO + 2NC) (you will find other accessories on page 28) Rated current is determined by the rated current module (rating plug). The module delivered with standard version corresponds to the maximum rated current of the circuit breaker. If a smaller rated current is required, its change is possible, see page 27. Permissible short-time withstand current Icw and rated short-circuit making capacity Icm of a switch-disconnector see page 47 (only for AC applications). 3) Measuring current transformers for vectorial addition or protection of N conductor shall be ordered separately, see page 36. 4) Only for size I and II. For weight see page 48. 2) 14 Arion Commercial information 3P COMPOSITION OF TYPE DESIGNATION Fixed design, 3-pole, AC Rated current In 1) Rear horizontal connections 630 800 1000 1250 1600 2000 2500 3200 4000 5000 6300 85 kA – size I H ARION WL1106-432- ARION WL1108-432- ARION WL1110-432- ARION WL1112-432- ARION WL1116-432- ARION WL1120-432- - Rated short-circuit ultimate breaking capacity Icu /440 V 100 kA – size II 100 kA – size III H H ARION WL1208-432- ARION WL1210-432- ARION WL1212-432- ARION WL1216-432- ARION WL1220-432- ARION WL1225-432- ARION WL1232-432- ARION WL1340-432- ARION WL1350-432- - 150 kA – size III C ARION WL1340-532- ARION WL1350-532- - Rear vertical connections 630 800 1000 1250 1600 2000 2500 3200 4000 5000 6300 ARION WL1106-431- ARION WL1108-431- ARION WL1110-431- ARION WL1112-431- ARION WL1116-431- ARION WL1120-431- - ARION WL1208-431- ARION WL1210-431- ARION WL1212-431- ARION WL1216-431- ARION WL1220-431- ARION WL1225-431- ARION WL1232-431- ARION WL1240-431- - ARION WL1340-431- ARION WL1350-431- ARION WL1363-431- ARION WL1340-531- ARION WL1350-531- ARION WL1363-531- ARION WL1208-433- ARION WL1210-433- ARION WL1212-433- ARION WL1216-433- ARION WL1220-433- ARION WL1225-433- ARION WL1232-433- - ARION WL1340-433- - - ARION WL1208-434- ARION WL1210-434- ARION WL1212-434- ARION WL1216-434- ARION WL1220-434- ARION WL1225-434- ARION WL1232-434- - ARION WL1340-434- - - Front connections one series of holes 630 800 1000 1250 1600 2000 2500 3200 4000 5000 6300 - Front connections two series of holes 630 ARION WL1106-434- 800 ARION WL1108-434- 1000 ARION WL1110-434- 1250 ARION WL1112-434- 1600 ARION WL1116-434- 2000 ARION WL1120-434- 2500 3200 4000 5000 6300 - Switch-disconnector unit (switch-disconnector) 2) AA Overcurrent release - without earth fault protection (circuit breaker) Overcurrent release ETU15B – protective functions LI 4) Overcurrent release ETU25B – protective functions LSI Overcurrent release ETU45B – protective functions LSIN 3) Overcurrent release ETU45B – protective functions LSIN, with display, number of lines 4 3) Overcurrent release ETU76B – protective functions LSIN, graphic display 3) BB CB EB FB NB Overcurrent release - with earth fault protection (circuit breaker) Overcurrent release ETU27B – protective functions LSING 3) Overcurrent release ETU45B – protective functions LSING 3) Overcurrent release ETU45B – protective functions LSING, with display, number of lines 4 3) Overcurrent release ETU76B – protective functions LSING, graphic display 3) DG EG FG NG 1 A A 2 Standard type designation Hand drive with mechanical closing Auxiliary switches: contacts 2200 (2NO + 2NC) (you will find other accessories on page 28) 1) Rated current is determined by the rated current module (rating plug). The module delivered with standard version corresponds to the maximum rated current of the circuit breaker. If a smaller rated current is required, its change is possible, see page 27. Permissible short-time withstand current Icw and rated short-circuit making capacity Icm of a switch-disconnector see page 47 (only for AC applications). 3) Measuring current transformers for vectorial addition or protection of N conductor shall be ordered separately, see page 36. 4) Only for size I and II. For weight see page 48. 2) 15 Arion Commercial information 3P COMPOSITION OF TYPE DESIGNATION Withdrawable design, 3-pole, AC Rated current In 1) [A] Rear horizontal connections 630 800 1000 1250 1600 2000 2500 3200 4000 5000 6300 Rated short-circuit ultimate breaking capacity Icu /440 V 66 kA – size II 66 kA – size I N S ARION WL1106-336- ARION WL1108-336- ARION WL1110-336- ARION WL1112-336- ARION WL1116-336- ARION WL1220-236- ARION WL1120-336- ARION WL1225-236- ARION WL1232-236- - 80 kA – size II S ARION WL1208-336- ARION WL1210-336- ARION WL1212-336- ARION WL1216-336- ARION WL1220-336- ARION WL1225-336- ARION WL1232-336- - 630 800 1000 1250 1600 2000 2500 3200 4000 5000 6300 ARION WL1106-235- ARION WL1108-235- ARION WL1110-235- ARION WL1112-235- ARION WL1116-235- ARION WL1120-235- - ARION WL1220-235- ARION WL1225-235- ARION WL1232-235- - ARION WL1106-335- ARION WL1108-335- ARION WL1110-335- ARION WL1112-335- ARION WL1116-335- ARION WL1120-335- - ARION WL1208-335- ARION WL1210-335- ARION WL1212-335- ARION WL1216-335- ARION WL1220-335- ARION WL1225-335- ARION WL1232-335- - 630 800 1000 1250 1600 2000 2500 3200 4000 5000 6300 ARION WL1106-237- ARION WL1108-237- ARION WL1110-237- ARION WL1112-237- ARION WL1116-237- ARION WL1120-237- - ARION WL1220-237- ARION WL1225-237- ARION WL1232-237- ARION WL1240-237- - ARION WL1106-337- ARION WL1108-337- ARION WL1110-337- ARION WL1112-337- ARION WL1116-337- ARION WL1120-337- - ARION WL1208-337- ARION WL1210-337- ARION WL1212-337- ARION WL1216-337- ARION WL1220-337- ARION WL1225-337- ARION WL1232-337- ARION WL1240-337- - 630 800 1000 1250 1600 2000 2500 3200 4000 5000 6300 ARION WL1106-238- ARION WL1108-238- ARION WL1110-238- ARION WL1112-238- ARION WL1116-238- ARION WL1120-238- - ARION WL1220-238- ARION WL1225-238- ARION WL1232-238- - ARION WL1106-338- ARION WL1108-338- ARION WL1110-338- ARION WL1112-338- ARION WL1116-338- ARION WL1120-338- - ARION WL1208-338- ARION WL1210-338- ARION WL1212-338- ARION WL1216-338- ARION WL1220-338- ARION WL1225-338- ARION WL1232-338- - NSE00967 55 kA – size I N ARION WL1106-236- ARION WL1108-236- ARION WL1110-236- ARION WL1112-236- ARION WL1116-236- ARION WL1120-236- - Without withdrawable device NSE00972 Rear vertical connections NSE00973 Rear flanged connections Switch-disconnector unit (switch-disconnector) 2) AA Overcurrent release - without earth fault protection (circuit breaker) Overcurrent release ETU15B – protective functions LI 4) Overcurrent release ETU25B – protective functions LSI Overcurrent release ETU45B – protective functions LSIN 3) Overcurrent release ETU45B – protective functions LSIN, with display, number of lines 4 3) Overcurrent release ETU76B – protective functions LSIN, graphic display 3) BB CB EB FB NB Overcurrent release - with earth fault protection (circuit breaker) Overcurrent release ETU27B – protective functions LSING 3) Overcurrent release ETU45B – protective functions LSING 3) Overcurrent release ETU45B – protective functions LSING, with display, number of lines 4 3) Overcurrent release ETU76B – protective functions LSING, graphic display 3) DG EG FG NG 1) 1 A A 2 Standard type designation Hand drive with mechanical closing Auxiliary switches: contacts 2200 (2NO + 2NC) (you will find other accessories on page 28) Rated current is determined by the rated current module (rating plug). The module delivered with standard version corresponds to the maximum rated current of the circuit breaker. If a smaller rated current is required, its change is possible, see page 27. Permissible short-time withstand current Icw and rated short-circuit making capacity Icm of a switch-disconnector see page 47 (only for AC applications). 3) Measuring current transformers for vectorial addition or protection of N conductor shall be ordered separately, see page 36. 4) Only for size I and II. For weight see page 48. 2) 16 Arion Commercial information 3P COMPOSITION OF TYPE DESIGNATION Withdrawable design, 3-pole, AC Rated current In 1) Rear horizontal connections 630 800 1000 1250 1600 2000 2500 3200 4000 5000 6300 85 kA - size I H ARION WL1106-436- ARION WL1108-436- ARION WL1110-436- ARION WL1112-436- ARION WL1116-436- ARION WL1120-436- - Rated short-circuit ultimate breaking capacity Icu /440 V 100 kA – size II 100 kA – size III H H ARION WL1208-436- ARION WL1210-436- ARION WL1212-436- ARION WL1216-436- ARION WL1220-436- ARION WL1225-436- ARION WL1232-436- ARION WL1340-436- ARION WL1350-436- - 150 kA – size III C ARION WL1340-536- ARION WL1350-536- - Without withdrawable device 630 800 1000 1250 1600 2000 2500 3200 4000 5000 6300 ARION WL1106-435- ARION WL1108-435- ARION WL1110-435- ARION WL1112-435- ARION WL1116-435- ARION WL1120-435- - ARION WL1208-435- ARION WL1210-435- ARION WL1212-435- ARION WL1216-435- ARION WL1220-435- ARION WL1225-435- ARION WL1232-435- - ARION WL1340-435- ARION WL1350-435- ARION WL1363-435- ARION WL1340-535- ARION WL1350-535- ARION WL1363-535- Rear vertical connections 630 800 1000 1250 1600 2000 2500 3200 4000 5000 6300 ARION WL1106-437- ARION WL1108-437- ARION WL1110-437- ARION WL1112-437- ARION WL1116-437- ARION WL1120-437- - ARION WL1208-437- ARION WL1210-437- ARION WL1212-437- ARION WL1216-437- ARION WL1220-437- ARION WL1225-437- ARION WL1232-437- ARION WL1240-437- - ARION WL1340-437- ARION WL1350-437- ARION WL1363-437- ARION WL1340-537- ARION WL1350-537- ARION WL1363-537- Rear flanged connections 630 800 1000 1250 1600 2000 2500 3200 4000 5000 6300 ARION WL1106-438- ARION WL1108-438- ARION WL1110-438- ARION WL1112-438- ARION WL1116-438- ARION WL1120-438- - ARION WL1208-438- ARION WL1210-438- ARION WL1212-438- ARION WL1216-438- ARION WL1220-438- ARION WL1225-438- ARION WL1232-438- - ARION WL1340-438- - - Switch-disconnector unit (switch-disconnector) 2) AA Overcurrent release - without earth fault protection (circuit breaker) Overcurrent release ETU15B – protective functions LI 4) Overcurrent release ETU25B – protective functions LSI Overcurrent release ETU45B – protective functions LSIN 3) Overcurrent release ETU45B – protective functions LSIN, with display, number of lines 4 3) Overcurrent release ETU76B – protective functions LSIN, graphic display 3) BB CB EB FB NB Overcurrent release - with earth fault protection (circuit breaker) Overcurrent release ETU27B – protective functions LSING 3) Overcurrent release ETU45B – protective functions LSING 3) Overcurrent release ETU45B – protective functions LSING, with display, number of lines 4 3) Overcurrent release ETU76B – protective functions LSING, graphic display 3) DG EG FG NG 1 A A 2 Standard type designation Hand drive with mechanical closing Auxiliary switches: contacts 2200 (2NO + 2NC) (you will find other accessories on page 28) 1) Rated current is determined by the rated current module (rating plug). The module delivered with standard version corresponds to the maximum rated current of the circuit breaker. If a smaller rated current is required, its change is possible, see page 27. Permissible short-time withstand current Icw and rated short-circuit making capacity Icm of a switch-disconnector see page 47 (only for AC applications). 3) Measuring current transformers for vectorial addition or protection of N conductor shall be ordered separately, see page 36. 4) Only for size I and II. For weight see page 48. 2) 17 Arion Commercial information 4P COMPOSITION OF TYPE DESIGNATION Fixed design, 4-pole, AC Rated current In 1) [A] Rear horizontal connections 630 800 1000 1250 1600 2000 2500 3200 4000 5000 6300 Rated short-circuit ultimate breaking capacity Icu /440 V 66 kA – size II 66 kA – size I N S ARION WL1106-342- ARION WL1108-342- ARION WL1110-342- ARION WL1112-342- ARION WL1116-342- ARION WL1220-242- ARION WL1120-342- ARION WL1225-242- ARION WL1232-242- - 80 kA – size II S ARION WL1208-342- ARION WL1210-342- ARION WL1212-342- ARION WL1216-342- ARION WL1220-342- ARION WL1225-342- ARION WL1232-342- - 630 800 1000 1250 1600 2000 2500 3200 4000 5000 6300 ARION WL1106-241- ARION WL1108-241- ARION WL1110-241- ARION WL1112-241- ARION WL1116-241- ARION WL1120-241- - ARION WL1220-241- ARION WL1225-241- ARION WL1232-241- ARION WL1240-241- - ARION WL1106-341- ARION WL1108-341- ARION WL1110-341- ARION WL1112-341- ARION WL1116-341- ARION WL1120-341- - ARION WL1208-341- ARION WL1210-341- ARION WL1212-341- ARION WL1216-341- ARION WL1220-341- ARION WL1225-341- ARION WL1232-341- ARION WL1240-341- - Front connections one series of holes 630 800 1000 1250 1600 2000 2500 3200 4000 5000 6300 ARION WL1106-243- ARION WL1108-243- ARION WL1110-243- ARION WL1112-243- ARION WL1116-243- - ARION WL1220-243- ARION WL1225-243- ARION WL1232-243- - ARION WL1106-343- ARION WL1108-343- ARION WL1110-343- ARION WL1112-343- ARION WL1116-343- - ARION WL1208-343- ARION WL1210-343- ARION WL1212-343- ARION WL1216-343- ARION WL1220-343- ARION WL1225-343- ARION WL1232-343- - Front connections two series of holes 630 800 1000 1250 1600 2000 2500 3200 4000 5000 6300 ARION WL1106-244- ARION WL1108-244- ARION WL1110-244- ARION WL1112-244- ARION WL1116-244- ARION WL1120-244- - ARION WL1220-244- ARION WL1225-244- ARION WL1232-244- - ARION WL1106-344- ARION WL1108-344- ARION WL1110-344- ARION WL1112-344- ARION WL1116-344- ARION WL1120-344- - ARION WL1208-344- ARION WL1210-344- ARION WL1212-344- ARION WL1216-344- ARION WL1220-344- ARION WL1225-344- ARION WL1232-344- - NSE00967 55 kA – size I N ARION WL1106-242- ARION WL1108-242- ARION WL1110-242- ARION WL1112-242- ARION WL1116-242- ARION WL1120-242- - NSE00969 NSE00968 NSE00979 Rear vertical connections Switch-disconnector unit (switch-disconnector) 2) AA Overcurrent release - without earth fault protection (circuit breaker) Overcurrent release ETU15B – protective functions LI 4) Overcurrent release ETU25B – protective functions LSI Overcurrent release ETU45B – protective functions LSIN 3) Overcurrent release ETU45B – protective functions LSIN, with display, number of lines 4 3) Overcurrent release ETU76B – protective functions LSIN, graphic display 3) BB CB EB FB NB Overcurrent release - s ochranou proti zemnímu zkratu (jistič) Overcurrent release ETU27B – ochranné funkce LSING 3) Overcurrent release ETU45B – ochranné funkce LSING 3) Overcurrent release ETU45B – ochranné funkce LSING, with display, number of lines 4 3) Overcurrent release ETU76B – ochranné funkce LSING, graphic display 3) DG EG FG NG 1) 1 A A 2 Standard type designation Hand drive with mechanical closing Auxiliary switches: contacts 2200 (2NO + 2NC) (you will find other accessories on page 28) Rated current is determined by the rated current module (rating plug). The module delivered with standard version corresponds to the maximum rated current of the circuit breaker. If a smaller rated current is required, its change is possible, see page 27. Permissible short-time withstand current Icw and rated short-circuit making capacity Icm of a switch-disconnector see page 47 (only for AC applications). 3) Internal measuring current transformer for protection of N conductor can be ordered with „F23“ code „F23“ see page 28. 4) Only for size I and II. For weight see page 48. 2) 18 Arion Commercial information 4P COMPOSITION OF TYPE DESIGNATION Fixed design, 4-pole, AC Rated current In 1) Rear horizontal connections 630 800 1000 1250 1600 2000 2500 3200 4000 5000 6300 85 kA – size I H ARION WL1106-442- ARION WL1108-442- ARION WL1110-442- ARION WL1112-442- ARION WL1116-442- ARION WL1120-442- - Rated short-circuit ultimate breaking capacity Icu /440 V 100 kA – size II 100 kA – size III H H ARION WL1208-442- ARION WL1210-442- ARION WL1212-442- ARION WL1216-442- ARION WL1220-442- ARION WL1225-442- ARION WL1232-442- ARION WL1340-442- ARION WL1350-442- - 130 kA – size III C ARION WL1340-542- ARION WL1350-542- - Rear vertical connections 630 800 1000 1250 1600 2000 2500 3200 4000 5000 6300 ARION WL1106-441- ARION WL1108-441- ARION WL1110-441- ARION WL1112-441- ARION WL1116-441- ARION WL1120-441- - ARION WL1208-441- ARION WL1210-441- ARION WL1212-441- ARION WL1216-441- ARION WL1220-441- ARION WL1225-441- ARION WL1232-441- ARION WL1240-441- - ARION WL1340-441- ARION WL1350-441- ARION WL1363-441- ARION WL1340-541- ARION WL1350-541- ARION WL1363-541- ARION WL1208-443- ARION WL1210-443- ARION WL1212-443- ARION WL1216-443- ARION WL1220-443- ARION WL1225-443- ARION WL1232-443- - ARION WL1340-443- - - ARION WL1208-444- ARION WL1210-444- ARION WL1212-444- ARION WL1216-444- ARION WL1220-444- ARION WL1225-444- ARION WL1232-444- - ARION WL1340-444- - - Front connections one series of holes 630 800 1000 1250 1600 2000 2500 3200 4000 5000 6300 - Front connections two series of holes 630 ARION WL1106-444- 800 ARION WL1108-444- 1000 ARION WL1110-444- 1250 ARION WL1112-444- 1600 ARION WL1116-444- 2000 ARION WL1120-444- 2500 3200 4000 5000 6300 - Switch-disconnector unit (switch-disconnector) 2) AA Overcurrent release - without earth fault protection (circuit breaker) Overcurrent release ETU15B – protective functions LI 4) Overcurrent release ETU25B – protective functions LSI Overcurrent release ETU45B – protective functions LSIN 3) Overcurrent release ETU45B – protective functions LSIN, with display, number of lines 4 3) Overcurrent release ETU76B – protective functions LSIN, graphic display 3) BB CB EB FB NB Overcurrent release - with earth fault protection (circuit breaker) Overcurrent release ETU27B – protective functions LSING 3) Overcurrent release ETU45B – protective functions LSING 3) Overcurrent release ETU45B – protective functions LSING, with display, number of lines 4 3) Overcurrent release ETU76B – protective functions LSING, graphic display 3) DG EG FG NG 1 A A 2 Standard type designation Hand drive with mechanical closing Auxiliary switches: contacts 2200 (2NO + 2NC) (you will find other accessories on page 28) 1) Rated current is determined by the rated current module (rating plug). The module delivered with standard version corresponds to the maximum rated current of the circuit breaker. If a smaller rated current is required, its change is possible, see page 27. Permissible short-time withstand current Icw and rated short-circuit making capacity Icm of a switch-disconnector see page 47 (only for AC applications). 3) Internal measuring current transformer for protection of N conductor can be ordered with „F23“ code „F23“ see page 28. 4) Only for size I and II. For weight see page 48. 2) 19 Arion Commercial information 4P COMPOSITION OF TYPE DESIGNATION Withdrawable design, 4-pole, AC Rated current In 1) [A] Rear horizontal connections 630 800 1000 1250 1600 2000 2500 3200 4000 5000 6300 Rated short-circuit ultimate breaking capacity Icu /440 V 66 kA – size II 66 kA – size I N S ARION WL1106-346- ARION WL1108-346- ARION WL1110-346- ARION WL1112-346- ARION WL1116-346- ARION WL1220-246- ARION WL1120-346- ARION WL1225-246- ARION WL1232-246- - 80 kA – size II S ARION WL1208-346- ARION WL1210-346- ARION WL1212-346- ARION WL1216-346- ARION WL1220-346- ARION WL1225-346- ARION WL1232-346- - 630 800 1000 1250 1600 2000 2500 3200 4000 5000 6300 ARION WL1106-245- ARION WL1108-245- ARION WL1110-245- ARION WL1112-245- ARION WL1116-245- ARION WL1120-245- - ARION WL1220-245- ARION WL1225-245- ARION WL1232-245- - ARION WL1106-345- ARION WL1108-345- ARION WL1110-345- ARION WL1112-345- ARION WL1116-345- ARION WL1120-345- - ARION WL1208-345- ARION WL1210-345- ARION WL1212-345- ARION WL1216-345- ARION WL1220-345- ARION WL1225-345- ARION WL1232-345- - 630 800 1000 1250 1600 2000 2500 3200 4000 5000 6300 ARION WL1106-247- ARION WL1108-247- ARION WL1110-247- ARION WL1112-247- ARION WL1116-247- ARION WL1120-247- - ARION WL1220-247- ARION WL1225-247- ARION WL1232-247- ARION WL1240-247- - ARION WL1106-347- ARION WL1108-347- ARION WL1110-347- ARION WL1112-347- ARION WL1116-347- ARION WL1120-347- - ARION WL1208-347- ARION WL1210-347- ARION WL1212-347- ARION WL1216-347- ARION WL1220-347- ARION WL1225-347- ARION WL1232-347- ARION WL1240-347- - 630 800 1000 1250 1600 2000 2500 3200 4000 5000 6300 ARION WL1106-248- ARION WL1108-248- ARION WL1110-248- ARION WL1112-248- ARION WL1116-248- ARION WL1120-248- - ARION WL1220-248- ARION WL1225-248- ARION WL1232-248- - ARION WL1106-348- ARION WL1108-348- ARION WL1110-348- ARION WL1112-348- ARION WL1116-348- ARION WL1120-348- - ARION WL1208-348- ARION WL1210-348- ARION WL1212-348- ARION WL1216-348- ARION WL1220-348- ARION WL1225-348- ARION WL1232-348- - NSE00967 55 kA – size I N ARION WL1106-246- ARION WL1108-246- ARION WL1110-246- ARION WL1112-246- ARION WL1116-246- ARION WL1120-246- - Without withdrawable device NSE00972 Rear vertical connections NSE00973 Rear flanged connections Switch-disconnector unit (switch-disconnector) 2) AA Overcurrent release - without earth fault protection (circuit breaker) Overcurrent release ETU15B – protective functions LI 4) Overcurrent release ETU25B – protective functions LSI Overcurrent release ETU45B – protective functions LSIN 3) Overcurrent release ETU45B – protective functions LSIN, with display, number of lines 4 3) Overcurrent release ETU76B – protective functions LSIN, graphic display 3) BB CB EB FB NB Overcurrent release - with earth fault protection (circuit breaker) Overcurrent release ETU27B – protective functions LSING 3) Overcurrent release ETU45B – protective functions LSING 3) Overcurrent release ETU45B – protective functions LSING, with display, number of lines 4 3) Overcurrent release ETU76B – protective functions LSING, graphic display 3) DG EG FG NG 1) 1 A A 2 Standard type designation Hand drive with mechanical closing Auxiliary switches: contacts 2200 (2NO + 2NC) (you will find other accessories on page 28) Rated current is determined by the rated current module (rating plug). The module delivered with standard version corresponds to the maximum rated current of the circuit breaker. If a smaller rated current is required, its change is possible, see page 27. Permissible short-time withstand current Icw and rated short-circuit making capacity Icm of a switch-disconnector see page 47 (only for AC applications). 3) Internal measuring current transformer for protection of N conductor can be ordered with „F23“ code „F23“ see page 28. 4) Only for size I and II. For weight see page 48. 2) 20 Arion Commercial information 4P COMPOSITION OF TYPE DESIGNATION Withdrawable design, 4-pole, AC Rated current In 1) Rear horizontal connections 630 800 1000 1250 1600 2000 2500 3200 4000 5000 6300 85 kA – size I H ARION WL1106-446- ARION WL1108-446- ARION WL1110-446- ARION WL1112-446- ARION WL1116-446- ARION WL1120-446- - Rated short-circuit ultimate breaking capacity Icu /440 V 100 kA – size II 100 kA – size III H H ARION WL1208-446- ARION WL1210-446- ARION WL1212-446- ARION WL1216-446- ARION WL1220-446- ARION WL1225-446- ARION WL1232-446- ARION WL1340-446- ARION WL1350-446- - 130 kA – size III C ARION WL1340-546- ARION WL1350-546- - Without withdrawable device 630 800 1000 1250 1600 2000 2500 3200 4000 5000 6300 ARION WL1106-445- ARION WL1108-445- ARION WL1110-445- ARION WL1112-445- ARION WL1116-445- ARION WL1120-445- - ARION WL1208-445- ARION WL1210-445- ARION WL1212-445- ARION WL1216-445- ARION WL1220-445- ARION WL1225-445- ARION WL1232-445- - ARION WL1340-445- ARION WL1350-445- ARION WL1363-445- ARION WL1340-545- ARION WL1350-545- ARION WL1363-545- Rear vertical connections 630 800 1000 1250 1600 2000 2500 3200 4000 5000 6300 ARION WL1106-447- ARION WL1108-447- ARION WL1110-447- ARION WL1112-447- ARION WL1116-447- ARION WL1120-447- - ARION WL1208-447- ARION WL1210-447- ARION WL1212-447- ARION WL1216-447- ARION WL1220-447- ARION WL1225-447- ARION WL1232-447- ARION WL1240-447- - ARION WL1340-447- ARION WL1350-447- ARION WL1363-447- ARION WL1340-547- ARION WL1350-547- ARION WL1363-547- Rear flanged connections 630 800 1000 1250 1600 2000 2500 3200 4000 5000 6300 ARION WL1106-448- ARION WL1108-448- ARION WL1110-448- ARION WL1112-448- ARION WL1116-448- ARION WL1120-448- - ARION WL1208-448- ARION WL1210-448- ARION WL1212-448- ARION WL1216-448- ARION WL1220-448- ARION WL1225-448- ARION WL1232-448- - ARION WL1340-448- - - Switch-disconnector unit (switch-disconnector) 2) AA Overcurrent release - without earth fault protection (circuit breaker) Overcurrent release ETU15B – protective functions LI 4) Overcurrent release ETU25B – protective functions LSI Overcurrent release ETU45B – protective functions LSIN 3) Overcurrent release ETU45B – protective functions LSIN, with display, number of lines 4 3) Overcurrent release ETU76B – protective functions LSIN, graphic display 3) BB CB EB FB NB Overcurrent release - with earth fault protection (circuit breaker) Overcurrent release ETU27B – protective functions LSING 3) Overcurrent release ETU45B – protective functions LSING 3) Overcurrent release ETU45B – protective functions LSING, with display, number of lines 4 3) Overcurrent release ETU76B – protective functions LSING, graphic display 3) DG EG FG NG 1 A A 2 Standard type designation Hand drive with mechanical closing Auxiliary switches: contacts 2200 (2NO + 2NC) (you will find other accessories on page 28) 1) Rated current is determined by the rated current module (rating plug). The module delivered with standard version corresponds to the maximum rated current of the circuit breaker. If a smaller rated current is required, its change is possible, see page 27. Permissible short-time withstand current Icw and rated short-circuit making capacity Icm of a switch-disconnector see page 47 (only for AC applications). 3) Internal measuring current transformer for protection of N conductor can be ordered with „F23“ code „F23“ see page 28. 4) Only for size I and II. For weight see page 48. 2) 21 Arion Commercial information 3P 4P COMPOSITION OF TYPE DESIGNATION Fixed design, 3-pole, 4-pole, DC switch-disconnectors Rated current In Size 3-pole design 4-pole design 1000 2000 40001) II II II ARION WL1210-8AA32- ARION WL1220-8AA32- ARION WL1240-8AA32- ARION WL1210-8AA42- ARION WL1220-8AA42- ARION WL1240-8AA42- 1000 2000 40001) II II II ARION WL1210-8AA31- ARION WL1220-8AA31- ARION WL1240-8AA31- ARION WL1210-8AA41- ARION WL1220-8AA41- ARION WL1240-8AA41- 1000 2000 II II ARION WL1210-8AA33- ARION WL1220-8AA33- ARION WL1210-8AA43- ARION WL1220-8AA43- 1000 2000 II II ARION WL1210-8AA34- ARION WL1220-8AA34- ARION WL1210-8AA44- ARION WL1220-8AA44- NSE00967 Rear horizontal connections NSE00979 Rear vertical connections NSE00968 Front connections one series of holes NSE00969 Front connections two series of holes 1 A A 2 Standard type designation Hand drive with mechanical closing Auxiliary switches: contacts 2200 (2NO + 2NC) (you will find other accessories on page 24) 1) Switchboard manufacturer must provide precautions for heat dissipation. Permissible rated short-time current ICW and short-circuit capacity ICC for non-automatic circuit-breakers see page 50. For weight see page 50. 22 Arion Commercial information 3P 4P COMPOSITION OF TYPE DESIGNATION Withdrawable design, 3-pole, 4-pole, DC switch-disconnectors Rated current In Size 3-pole design 4-pole design 1000 2000 40001) II II II ARION WL1210-8AA35- ARION WL1220-8AA35- ARION WL1240-8AA35- ARION WL1210-8AA45- ARION WL1220-8AA45- ARION WL1240-8AA45- 1000 2000 40001) II II II ARION WL1210-8AA36- ARION WL1220-8AA36- ARION WL1240-8AA36- ARION WL1210-8AA46- ARION WL1220-8AA46- ARION WL1240-8AA46- 1000 2000 40001) II II II ARION WL1210-8AA37- ARION WL1220-8AA37- ARION WL1240-8AA37- ARION WL1210-8AA47- ARION WL1220-8AA47- ARION WL1240-8AA47- 1000 2000 40001) II II II ARION WL1210-8AA38- ARION WL1220-8AA38- ARION WL1240-8AA38- ARION WL1210-8AA48- ARION WL1220-8AA48- ARION WL1240-8AA48- Without withdrawable device NSE00967 Rear horizontal connections NSE00972 Rear vertical connections NSE00973 Rear flanged connection 1 A A 2 Standard type designation Hand drive with mechanical closing Auxiliary switches: contacts 2200 (2NO + 2NC) (you will find other accessories on page 24) 1) Switchboard manufacturer must provide precautions for heat dissipation. Permissible rated short-time current ICW and short-circuit capacity ICC for non-automatic circuit-breakers see page 50. For weight see page 50. 23 Arion Commercial information 3P 4P BASIC ACCESSORIES Selected type designation ARION WL1-- Hand drives with mechanical closing 1 Hand drives with electrical closing – closing release: load factor 100 % 110 V a.c./110 V d.c. 230 V a.c./220 V d.c. 2 3 Motor and hand drives with electrical closing – closing release: load factor 100 % - for permanent load 230 V a.c./220 V d.c. 110 V a.c./d.c. 24 V d.c. - different operating voltages for motor drive and closing release see page 30 1st auxiliary release Without 1st auxiliary release Shunt trips – load factor 100 % - for permanent load 24 V d.c. 30 V d.c. 48 V d.c. 60 V d.c. 110 V a.c./d.c. 230 V a.c./220 V d.c. 2nd auxiliary release Without 2nd auxiliary release Shunt trips – load factor 100 % - for permanent load 24 V d.c. 30 V d.c. 48 V d.c. 60 V d.c. 110 V a.c./d.c. 230 V a.c./220 V d.c. Undervoltage releases – short-time delayed 80 or 200 ms 24 V d.c. 30 V d.c. 48 V d.c. 60 V d.c. 110 V a.c./d.c. 230 V a.c./220 V d.c. 400 V a.c. Undervoltage releases – delayed 0.2 až 3.2 s 48 V d.c. 110 V a.c./d.c. 230 V a.c./220 V d.c. 400 V a.c. Auxiliary switches 2NO + 2NC 4NO + 4NC 6NO + 2NC 5NO + 3NC 24 4 5 6 A B C D E F G A B C D E F G J K L U M N P Q R S T 2 4 7 8 Arion Commercial information 3P 4P ADDITIONAL ACCESSORIES Method of connection ARION WL1--- Z Selected type designation Method of connection of a fixed design circuit breaker - if this method of connection is selected, on the 12th place of the type designation there must be „2“ (ARION WL1-2-) Upper terminals Lower terminals For circuit breaker size – rated current Code rear horizontal connection front connection – one series of holes I-16; II-20; II25; II-32; III-40 N11 rear vertical connection rear horizontal connection rear horizontal connection rear vertical connection I-20; II-20; II25; II-32; III-40; III-50 I-20; II-20; II25; II-32; III-40; III-50 N20 N24 Method of connection of a circuit breaker of withdrawable design and of withdrawable device - if this method of connection is selected, on the 12th place of the type designation there must be „6“ (ARION WL1-6-) Upper terminals Lower terminals For circuit breaker size – rated current front connection – one series of holes front connection – one series of holes I-16; II-20; II25; II-32; III-40 front connection – two series of holes front connection – two series of holes I-20; II-20; II25; II-32; III-40 Code P00 P01 rear horizontal connection front connection – one series of holes I-16; II-20; II25; II-32; III-40 P07 rear vertical connection flanged connection rear horizontal connection rear horizontal connection rear horizontal connection rear vertical connection I-20; II-20; II25; II-32; III-40; III-50 I-20; II-20; II25; II-32; III-40 I-20; II-20; II25; II-32; III-40; III-50 P18 P19 P23 Rear flanged connection withdrawable design Front connection one series of holes Front connection two series of holes NSE00969 NSE00968 NSE00973 Rear vertical connection withdrawable design NSE00972 Rear vertical connection fixed design NSE00979 NSE00967 Rear horizontal connection Terminal block Selected type designation ARION WL1--- Z Method of connection of auxiliary circuits of circuit breaker by means of screwless terminals - tension spring principle (normally the circuit breaker is equipped with screw terminals) for fixed design N61 for withdrawable design P61 25 Arion Commercial information 3P 4P ADDITIONAL ACCESSORIES Closing release and motor drives with different operating voltage Selected type designation ARION WL1- - -Z Closing releases - load factor 100 %, if this method of control is selected, there must be „1” set on the 13th place of the type designation (ARION WL1--1) 24 V d.c. 30 V d.c. 48 V d.c. 60 V d.c. 110 V a.c./d.c. 230 V a.c./220 V d.c. Code M21 M22 M23 M24 M25 M26 Closing releases - load factor 5 % - overexcitation (pull-in time) 25 ÷ 60 ms, max. loading time 3 s, if this method of control is selected, there must be „1” set on the 13th place of the type designation (ARION WL1--1) 24 ÷ 30 V d.c. 48 ÷ 60 V d.c. 110 V a.c./d.c. 230 V a.c./220 V d.c. Motor drives - if this method of control is selected, there must be „1” set on the 13th place of the type designation (ARION WL1--1) 24 ÷ 30 V d.c. Code M31 M33 M35 M36 Code M01 48 ÷ 60 V d.c. M03 110 V a.c./d.c. 230 V a.c./220 V d.c. M05 M06 Shunt trips Selected type designation ARION WL1- - -Z Shunt trips - load factor 5 % - overexcitation (pull-in time) 25 ÷ 60 ms, max. loading time 3 s, if this method of control is selected, there must be „A” on the 14th or 15th position of the type designation (ARION WL1--A, ARION WL1--A) 24 ÷ 30 V d.c. 48 ÷ 60 V d.c. 110 V a.c./d.c. 230 V a.c./220 V d.c. Code M41 M43 M45 M46 Tinned connections Selected type designation ARION WL1- - -Z - for complete withdrawable design, individual frame with horizontal or flanged connection - can be used in atmosphere containing sulphur (etc. pulp and paper industry) Code - for size I, II, III A08 26 Commercial information Arion 3P 4P ADDITIONAL ACCESSORIES Rated operating voltage 1000/1150 V ARION WL1--- Z Selected type designation Rated voltage 1000 V for circuit breakers AC/DC and switch-disconnectors AC/DC Code - if withdrawable circuit breaker and withdrawable device are ordered separately, the complement code „A05” must be stated for both the withdrawable circuit breaker and withdrawable device A05 - for IT network with Ue ≤ 690 V a.c. - only for circuit breakers and switch-disconnectors of size I (2000 A) with Icu = 85 kA, II and III with Icu = 100 kA Rated voltage 1150 V for circuit breakers AC and switch-disconnectors AC - if withdrawable circuit breaker and withdrawable device are ordered separately, the complement code „A15” must be stated for both the withdrawable circuit breaker and withdrawable device A15 - only for circuit breakers or switch-disconnectors of size II with Icu = 100 kA - circuit breaker size III with Icu = 130kA/150kA (breaking capacity C) can be used at Ue = 1150 V a.c. without accessory A15 Rated current modules ARION WL1--- Z Selected type designation Rated current modules - it is possible to order only one module per circuit breaker (not possible for overcurrent release ETU15B) - standardly delivered rated current module corresponds to the max. rated current of the circuit breaker Size I Size II Rated current In 250 A + + 315 A + + 400 A + + 500 A + + 630 A + + 800 A + + 1000 A + + 1250 A + + 1600 A + + 2000 A + + 2500 A – + 3200 A – + 4000 A – + 5000 A – – 6300 A – – + it can be used, – it cannot be used Size III – – – – – – – + + + + + + + + Code B02 B03 B04 B05 B06 B08 B10 B12 B16 B20 B25 B32 B40 B50 B63 Signal switches ARION WL1--- Z Selected type designation Signal switches Code For storage device state signalling – cannot be combined with codes „F01“, „F02“ and „F12“ C20 For „Ready-to-close“ state signalling C22 For signalling of „switched off by 1st auxiliary release“ - cannot be combined with codes „F01“, „F02“ and „F12“ C26 For signalling of „switched off by 2nd auxiliary release“ - cannot be combined with codes „F01“, „F02“ and „F12“ C27 For „Switched off by overcurrent release“ signalling - cannot be combined with codes „F01“, „F02“ and „F12“ K07 Working position Test position Disconnected position For position signalling in the withdrawable device - 3 CO 1p 1p 1p R15 For position signalling in the withdrawable device - 6 CO 3p 2p 1p R16 27 Arion Commercial information 3P 4P ADDITIONAL ACCESSORIES Control presentation Selected type designation ARION WL1--- Z Control presentation Code Counter of cycles - number of places 5 - possible only in combination with motor drive C01 Emergency OFF push-button – mushroom push-button in the place of mechanical button OFF S24 Switch for motor drive - only for circuit breaker with motor drive, cannot be combined with codes „C11“, „C12“, „C14“ and „C15“ S25 Electrical ON push-button on the front control panel of the circuit breaker – possible only for circuit breakers with closing release – cannot be combined with codes „F01“, „F02“, „F12“ and „S25“ For electrical ON on the front panel with sealable cap C11 For electrical ON on the front panel, lock CES C12 Automatic reset devices - automatic reset of the circuit breaker reclosing blocking after its switching off by overcurrent release K01 Remote reset devices - remote reset of the indicating push-button „switching off by overcurrent release“ and remote reset of circuit breaker reclosing blocking after its switching off by overcurrent release 24 V d.c. 48 V d.c. 110 V a.c./d.c. 230 V a.c./220 V d.c. K10 K11 K12 K13 Data communication device and measuring function Selected type designation ARION WL1--- Z Data communication – circuit breaker must be equipped at least with ETU45B Code BSS module - circuit breaker status sensor F01 Data communication devices PROFIBUS - complete data communication PROFIBUS - COM15 module, BSS module, connecting cables 2 m - if withdrawable circuit breaker and withdrawable device are ordered separately, the complement code „F02” must be stated for both the withdrawable circuit breaker and withdrawable device - the overcurrent release ETU45B must be set via BDA adapter or via PC equipped with profibus card and SW ES Switch Power - power supply 6EP1333-2AA01 shall be bought additionally F02 Data communication devices MODBUS - complete data communication MODBUS - COM16 module, BSS module, connecting cables 2 m - if withdrawable circuit breaker and withdrawable device are ordered separately, the complement code „F12” must be stated for both the withdrawable circuit breaker and withdrawable device - the overcurrent release ETU45B must be set via BDA adapter - power supply 6EP1333-2AA01 shall be bought additionally F12 Measuring function module Code Measuring function Plus (does not contain data communication) – for the measuring function, measuring voltage transformers are necessary, see page 36 and voltage source 6EP1333-2AA01 F05 Internal measuring current transformers for N conductor Size I, II, III - it is only possible for 4-pole circuit breakers with releases ETU27B up to ETU76B Code EMC noise suppressing filters For interference suppression - attenuation in the range 40 kHz ÷ 10 MHz > 40 dB - application e.g. in IT networks or for frequency converters Code 28 F23 F31 Commercial information Arion 3P 4P ADDITIONAL ACCESSORIES Blocking and locking Selected type designation ARION WL1--- Z Mechanical interlockings – blocking module with Bowden cable 2 m - it is possible to block two or three circuit breakers - each must contain mechanical interlocking - for blocking of three circuit breakers it is necessary to buy one additional Bowden cable to each circuit breaker – see page 37 Code For fixed design For withdrawable design Only for withdrawable device Only for circuit breaker in withdrawable design S55 R55 R56 R57 Locking devices against unauthorized closing – for both fixed and withdrawable circuit breaker - after locking, it is not possible to switch on the circuit breaker mechanically or electrically - the locking acts only on the given circuit breaker - meets the requirements of EN 60 204 for the main switch and EN 60 947-2 for safe disconnection Lock CES Lock IKON Set for locks FORTRESS or CASTELL – preparation for locks, the locks are not included in the delivery, they shall be ordered directly at the manufacturer Set for padlocks Lock RONIS Lock PROFALUX Code S01 S03 S05 S07 S08 S09 Locking devices against unauthorized closing for withdrawable circuit breaker - after locking, it is not possible to switch on the circuit breaker mechanically or electrically - the locking acts on each circuit breaker inserted into the withdrawable device - meets the requirements of EN 60 204 for the main switch and EN 60 947-2 for safe disconnection Code For circuit breaker in withdrawable design, lock PROFALUX For circuit breaker in withdrawable design, lock CES For circuit breaker in withdrawable design, lock RONIS R60 R61 R68 Locking devices of the storage device lever - it is not possible to wind up the circuit breaker manually Code For storage device lever, set for padlocks S33 Locking devices against shifting - prevents from crank withdrawal for shifting Code Lock PROFALUX Lock CES Lock RONIS S75 S71 S76 Locking devices against shifting in disconnected position - consists of the Bowden cable and the lock in the switchboard door Code Lock PROFALUX Lock CES Lock RONIS R85 R81 R86 Blocking devices Code Against switchboard door opening S30 R30 R50 for circuit breaker in fixed design, in ON state for circuit breaker in withdrawable design, in operating position Against shifting of the circuit breaker at opened switchboard door 29 Arion Commercial information 3P 4P ADDITIONAL ACCESSORIES Arc chute covers, insulation covers, door sealing frames Selected type designation ARION WL1--- Z Arc chute cover Arc chute cover - for withdrawable design, it is installed on the withdrawable device - not possible for 1000/1150 V design - not possible for DC design R10 Code Insulation cover Code Insulation cover - for withdrawable design, it is installed on the withdrawable device (covers power contacts in the withdrawable device) - lockable by a padlock (the padlock is not included in the delivery) R21 Door sealing frame Code Door sealing frame - it is installed on the switchboard door, degree of protection IP41 T40 30 R10 Arion Commercial information 3P 4P SEPARATELY DELIVERED ACCESSORIES Connecting sets – fixed design - the set contains one terminal with connecting material for terminal mounting on the circuit breaker - the data are valid for one terminal, if not stated otherwise - for 3-pole design, 3 terminals are necessary for upper and 3 terminals for lower side, for 4-pole design, 4 terminals are necessary for upper and 4 terminals for lower side Front connections one series of holes NSE-01010 NSE-01010 Size I I II II II III Rated current 1000 A 1) 1600 A 1) 2000 A 2500 A 3200 A 4000 A I 1000 A 1) I 1600 A 1) II 2000 A II 2500 A II 3200 A III 4000 A 1) Only for Icu 55 and 66 kA. Type 3WL9111-0AL01-0AA0 3WL9111-0AL02-0AA0 3WL9111-0AL03-0AA0 3WL9111-0AL04-0AA0 3WL9111-0AL05-0AA0 3WL9111-0AL06-0AA0 Product code 34739 34740 20371 34741 34742 34743 Description Upper terminal Upper terminal Upper terminal Upper terminal Upper terminal Upper terminal Weight [kg] 1.000 2.000 2.300 4.500 4.400 6.000 Package [pcs] 1 1 1 1 1 1 3WL9111-0AL51-0AA0 3WL9111-0AL52-0AA0 3WL9111-0AL53-0AA0 3WL9111-0AL54-0AA0 3WL9111-0AL55-0AA0 3WL9111-0AL56-0AA0 34744 34745 34746 34747 34748 34749 Lower terminal Lower terminal Lower terminal Lower terminal Lower terminal Lower terminal 1.200 1.700 2.000 3.700 3.600 6.400 1 1 1 1 1 1 Front connections two series of holes NSE-01011 Size I I II II II III Rated current 1000 A 2000 A 2000 A 2500 A 3200 A 4000 A Type 3WL9111-0AL07-0AA0 3WL9111-0AL08-0AA0 3WL9111-0AL11-0AA0 3WL9111-0AL12-0AA0 3WL9111-0AL13-0AA0 3WL9111-0AL14-0AA0 Product code 19341 19342 19343 19344 19345 14532 Description Upper terminal Upper terminal Upper terminal Upper terminal Upper terminal Upper terminal Weight [kg] 1.000 2.000 2.300 4.500 4.400 6.000 Package [pcs] 1 1 1 1 1 1 NSE-01011 I I II II II III 1000 A 2000 A 2000 A 2500 A 3200 A 4000 A 3WL9111-0AL57-0AA0 3WL9111-0AL58-0AA0 3WL9111-0AL61-0AA0 3WL9111-0AL62-0AA0 3WL9111-0AL63-0AA0 3WL9111-0AL64-0AA0 19346 19347 19348 19349 19350 14354 Lower terminal Lower terminal Lower terminal Lower terminal Lower terminal Lower terminal 1.200 1.700 2.000 3.700 3.600 6.400 1 1 1 1 1 1 Weight [kg] 0.500 1.600 5.000 Package [pcs] 1 1 1 Rear vertical connections Size Rated current Type Product code Description 19351 Upper or lower terminal I 2000 A 3WL9111-0AM01-0AA02) 19352 Upper or lower terminal II 3200 A 3WL9111-0AM02-0AA03) III 6300 A 3WL9111-0AM03-0AA0 14355 Upper or lower terminal 2) Up to (inclusive) 1000 A one terminal is needed per pole, up to (inclusive) 2000 A two terminals are needed per pole. 3) Up to (inclusive) 2500 A one terminal is needed per pole, up to (inclusive) 3200 A two terminals are needed per pole. NSE-01012 In your order always state both type designation and product code, if any. 31 Arion Commercial information 3P 4P SEPARATELY DELIVERED ACCESSORIES Connecting sets – withdrawable design - the set contains one terminal with connecting material for terminal mounting on the circuit breaker - the data are valid for one terminal, if not stated otherwise - for 3-pole design, 3 terminals are necessary for upper and 3 terminals for lower side, for 4-pole design, 4 terminals are necessary for upper and 4 terminals for lower side Front connections one series of holes NSE-01013 Size Rated current Type Product code Description Weight [kg] 3WL9111-0AN01-0AA0 34750 Upper or lower terminal 1.100 I 1000 A 1) 3WL9111-0AN02-0AA0 14462 Upper or lower terminal 1.700 I 1600 A 1) II 2000 A 3WL9111-0AN03-0AA0 34751 Upper or lower terminal 1.900 II 2500 A 3WL9111-0AN04-0AA0 34752 Upper or lower terminal 3.700 II 3200 A 3WL9111-0AN05-0AA0 34753 Upper or lower terminal 3.600 III 4000 A 3WL9111-0AN06-0AA0 34754 Upper or lower terminal 6.400 - on both upper and lower side it is necessary to use supports see „Supports for front connection with one or two rows of holes“ 1) Only for Icu 55 and 66 kA. Package [pcs] 1 1 1 1 1 1 Size Rated current Type Product code Description Weight [kg] I 1000 A 3WL9111-0AN07-0AA0 19353 Upper or lower terminal 1.100 I 2000 A 3WL9111-0AN08-0AA0 19354 Upper or lower terminal 1.700 II 2000 A 3WL9111-0AN11-0AA0 19355 Upper or lower terminal 1.900 II 2500 A 3WL9111-0AN12-0AA0 19356 Upper or lower terminal 3.700 II 3200 A 3WL9111-0AN13-0AA0 19357 Upper or lower terminal 3.600 III 4000 A 3WL9111-0AN14-0AA0 19358 Upper or lower terminal 6.400 - on both upper and lower side it is necessary to use supports see „Supports for front connection with one or two rows of holes“ Package [pcs] 1 1 1 1 1 1 Front connections two series of holes NSE-01014 Supports for front connection of withdrawable design Size I II III I II III Number of poles 3-pole 3-pole 3-pole 4-pole 4-pole 4-pole Type 3WL9111-0AN41-0AA0 3WL9111-0AN42-0AA0 3WL9111-0AN43-0AA0 3WL9111-0AN44-0AA0 3WL9111-0AN45-0AA0 3WL9111-0AN46-0AA0 Product code 19368 19369 19370 19371 19372 19373 NSE-01017 In your order always state both type designation and product code, if any. 32 Weight [kg] 0.800 1.200 1.200 1.200 1.200 1.200 Package [pcs] 1 1 1 1 1 1 Commercial information Arion 3P 4P SEPARATELY DELIVERED ACCESSORIES Withdrawable device, 3-pole, 4-pole, AC Size Max. rated current 3-pole 4-pole 1000 1600 2000 2500 3200 4000 3WL9211-1AA-A1 3WL9211-2AA-A1 3WL9212-3AA-A1 3WL9212-4AA-A1 3WL9212-5AA-A1 3WL9213-6AA-A1 3WL9211-1BA-A1 3WL9211-2BA-A1 3WL9212-3BA-A1 3WL9212-4BA-A1 3WL9212-5BA-A1 3WL9213-6BA-A1 I I I II II II III 1000 1600 2000 2000 2500 3200 4000 3WL9211-1AB-A1 3WL9211-2AB-A1 3WL9211-3AB-A1 3WL9212-3AB-A1 3WL9212-4AB-A1 3WL9212-5AB-A1 3WL9213-6AB-A1 3WL9211-1BB-A1 3WL9211-2BB-A1 3WL9211-3BB-A1 3WL9212-3BB-A1 3WL9212-4BB-A1 3WL9212-5BB-A1 3WL9213-6BB-A1 I I I II II II III III 1000 1600 2000 2000 2500 3200 4000 5000 3WL9211-1AC-A1 3WL9211-2AC-A1 3WL9211-3AC-A1 3WL9212-3AC-A1 3WL9212-4AC-A1 3WL9212-5AC-A1 3WL9213-6AC-A1 3WL9213-7AC-A1 3WL9211-1BC-A1 3WL9211-2BC-A1 3WL9211-3BC-A1 3WL9212-3BC-A1 3WL9212-4BC-A1 3WL9212-5BC-A1 3WL9213-6BC-A1 3WL9213-7BC-A1 I I I II II II II III III III 1000 1600 2000 2000 2500 3200 4000 4000 5000 6300 3WL9211-1AD-A1 3WL9211-2AD-A1 3WL9211-3AD-A1 3WL9212-3AD-A1 3WL9212-4AD-A1 3WL9212-5AD-A1 3WL9212-6AD-A1 3WL9213-6AD-A1 3WL9213-7AD-A1 3WL9213-8AD-A1 3WL9211-1BD-A1 3WL9211-2BD-A1 3WL9211-3BD-A1 3WL9212-3BD-A1 3WL9212-4BD-A1 3WL9212-5BD-A1 3WL9212-6BD-A1 3WL9213-6BD-A1 3WL9213-7BD-A1 3WL9213-8BD-A1 I I I II II II III 1000 1600 2000 2000 2500 3200 4000 3WL9211-1AE-A1 3WL9211-2AE-A1 3WL9211-3AE-A1 3WL9212-3AE-A1 3WL9212-4AE-A1 3WL9212-5AE-A1 3WL9213-6AE-A1 3WL9211-1BE-A1 3WL9211-2BE-A1 3WL9211-3BE-A1 3WL9212-3BE-A1 3WL9212-4BE-A1 3WL9212-5BE-A1 3WL9213-6BE-A1 NSE00968 Front connections one series of holes I I II II II III NSE00969 Front connections two series of holes NSE00967 Rear horizontal connections NSE00972 Rear vertical connections NSE00973 Rear flanged connections - Auxiliary circuit terminal blocks Without connector 1 connector 2 connectors 3 connectors 4 connectors Terminal block type Without terminal block Screw terminals Spring terminals Signalling of position Without switches For position signalling, 3CO For position signalling, 6CO Insulation cover Without insulation cover With insulation cover Other accessories of withdrawable device must be ordered by means of complement codes For weight see page 48. 0 1 2 3 4 0 1 2 0 1 2 A B 33 Arion Commercial information 3P 4P ADDITIONAL ACCESSORIES Withdrawable devices, 3-pole, 4-pole, DC Size Max. rated current 3-pole 4-pole 2000 3WL9212-3DA-A1 3WL9212-3EA-A1 II 2000 3WL9212-3DB-A1 3WL9212-3EB-A1 II II 2000 4000 3WL9212-3DC-A1 3WL9212-6DC-A1 3WL9212-3EC-A1 3WL9212-6EC-A1 II II 2000 4000 3WL9212-3DD-A1 3WL9212-6DD-A1 3WL9212-3EE-A1 3WL9212-6ED-A1 II II 2000 4000 3WL9212-3DE-A1 3WL9212-6DE-A1 3WL9212-3ED-A1 3WL9212-6EE-A1 Front connections one series of holes NSE00968 II NSE00969 Front connections two series of holes NSE00967 Rear horizontal connections NSE00972 Rear vertical connections NSE00973 Rear flanged connection - Auxiliary circuit terminal blocks Without connector 1 connector 2 connectors 3 connectors 4 connectors Terminal block type Without terminal block Screw terminals Spring terminals Signalling of position Without switches For position signalling, 3CO For position signalling, 6CO Insulation cover Without insulation cover With insulation cover Other accessories of withdrawable device must be ordered by means of complement codes. For weight see page 48. 34 0 1 2 3 4 0 1 2 0 1 2 A B Commercial information Arion 3P 4P SEPARATELY DELIVERED ACCESSORIES Rated current modules I nIn ==3200 3200A A NSE00992 Rated current 250 A 315 A 400 A 500 A 630 A 800 A 1000 A 1250 A 1600 A 2000 A 2500 A 3200 A 4000 A 5000 A 6300 A Type 3WL9111-0AA51-0AA0 3WL9111-0AA52-0AA0 3WL9111-0AA53-0AA0 3WL9111-0AA54-0AA0 3WL9111-0AA55-0AA0 3WL9111-0AA56-0AA0 3WL9111-0AA57-0AA0 3WL9111-0AA58-0AA0 3WL9111-0AA61-0AA0 3WL9111-0AA62-0AA0 3WL9111-0AA63-0AA0 3WL9111-0AA64-0AA0 3WL9111-0AA65-0AA0 3WL9111-0AA66-0AA0 3WL9111-0AA67-0AA0 Product code 34755 34756 34757 34758 34759 34628 34760 34761 34762 34763 34764 34765 34766 34767 34768 Description Size I, II Size I, II Size I, II Size I, II Size I, II Size I, II Size I, II Size I, II, III Size I, II, III Size I, II, III Size II, III Size II, III Size II, III Size III Size III Weight [kg] 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.03 Package [pcs] 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 - at insertion of the rated current module (rating plug) into the overcurrent release UTU25B, ETU45B or ETU76B , the rated current of the circuit breaker is changed to the value of the rated current of the module - rated current can only be decreased - the rated current module with the rated current of the selected circuit breaker is part of every circuit breaker or overcurrent release - not possible for overcurrent release ETU15B Test devices Type 3WL9111-0AT32-0AA0 3WL9111-0AT44-0AA0 Product code 36687 36087 Description Hand tester for ETU15B - ETU76B Test device for testing of tripping characteristics - for ETU15B - ETU76B Weight [kg] 1.000 8.21 Package [pcs] 1 1 Description Weight [kg] Digital output module with rotary switch - relay outputs 0.400 Digital output module, possibility of programming - relay outputs 0.400 Digital input module 0.400 Analog output module 0.400 ZSS module - time shortened selectivity control 0.400 For CubicleBUS modules and circuit breakers with data communication, length 0.2 m 0.500 For CubicleBUS modules and circuit breakers with data communication, length 1 m 0.500 For CubicleBUS modules and circuit breakers with data communication, length 2 m 0.500 For CubicleBUS modules and circuit breakers without data communication, length 2 m 0.500 Package [pcs] 1 1 1 1 1 1 1 1 1 CubicleBUS modules NSE-01023 Type Product code 3WL9111-0AT26-0AA0 17878 3WL9111-0AT20-0AA0 17914 3WL9111-0AT27-0AA0 34772 3WL9111-0AT23-0AA0 34773 3WL9111-0AT21-0AA0 34774 3WL9111-0BC04-0AA0 34778 3WL9111-0BC02-0AA0 34779 3WL9111-0BC03-0AA0 34780 3WL9111-0BC05-0AA0 34781 - each module is delivered with a 0.2 m cable for interconnection of individual modules - for connection of CubicleBUS modules to the circuit breaker, one connecting cable is necessary (it is not delivered with the modules) - circuit breaker must be equipped at least with ETU45B Voltage sources Type 6EP1332-2BA10 Product code 33325 Voltage Current Upri = 230 V a.c., Usec = 24 V d.c. In = 2.5 A Weight [kg] 0.400 Package [pcs] 1 6EP1333-2AA01 33505 Upri = 230 V a.c., Usec = 24 V d.c. In = 5 A 0.500 1 - the source is necessary for the circuit breakers equipped with data communication or Plus measuring function In your order always state both type designation and product code, if any. 35 Arion Commercial information 3P 4P SEPARATELY DELIVERED ACCESSORIES Data communication devices and measuring function Type 3WL9111-0AT28-0AA0 Product code Name Description Weight [kg] 36086 BDA adapter Parameterization, control, diagnostics and testing 0.9 of circuit breakers Arion via RS232 - interface RS232 - programmed by means of PC Internet Explorer + JAVA2 VM 1.4.0-01 - includes cable for interconnection of BDA adapter and overcurrent release of the circuit breaker (the cable is not suitable for longtime connection of BDA adapter) - no other software is needed - circuit breaker must be equipped at least with ETU45B Package [pcs] 1 3WL9111-0AT33-0AA0 15968 BDA plus adapter Parameterization, control, diagnostics and testing of circuit breakers Arion via ETHERNET - interface ETHERNET and RS232 - programmed by means of PC Internet Explorer + JAVA2 VM 1.4.0-01 - includes cable for interconnection of BDA adapter and overcurrent release of the circuit breaker (the cable is not suitable for long-time connection of BDA adapter) - no other software is needed - circuit breaker must be equipped at least with ETU45B 1.8 1 3WL9111-0BC22-0AA0 36690 For BDA adapter and overcurrent release ETU Release 2, length 1 m 0.8 1 3WL9111-0BC21-0AA0 34776 Connecting cable Connecting cable For BDA adapter and for circuit breaker - suitable for long-time connection - the cable is not necessary, if the circuit breaker is equipped with data communication PROFIBUS or CubicleBUS modules 0.5 1 3ZS2311-0CC10-0YA0 34777 Parameterization software - parameterization, control, diagnostics and testing of circuit breakers Arion via PROFIBUS - compatible with WIN 95, WIN 98, WIN NT, WIN 2000, WIN XP - the circuit breaker must be equipped with data communication PROFIBUS - in addition, for PC there must be a PROFIBUS card 1 1 Description Class of accuracy 0.5, 3-pole design Weight [kg] 2.7 Package [pcs] 1 Description Without copper busbars Without copper busbars Without copper busbars With copper busbars With copper busbars With copper busbars Weight [kg] 0.5 0.6 0.8 1.6 4.26 8.5 Package [pcs] 1 1 1 1 1 1 NSE-01024 Switch ES Power Measuring voltage transformers Operating voltage 380 ÷ 690 V a.c. Type 3WL9111-0BB68-0AA0 Product code 34154 External measuring current transformers for N conductor NSE00991 NSE00990 36 Circuit breaker size Type Product code I 3WL9111-0AA21-0AA0 34769 II 3WL9111-0AA22-0AA0 20513 III 3WL9111-0AA23-0AA0 34770 I 3WL9111-0AA31-0AA0 20112 II 3WL9111-0AA32-0AA0 20111 III 3WL9111-0AA33-0AA0 34653 In your order always state both type designation and product code, if any. Commercial information Arion 3P 4P SEPARATELY DELIVERED ACCESSORIES Auxiliary power sources for shunt trips Operating voltage 110 V a.c./d.c. Type 3WL9111-0BA13-0AA0 Product code 36098 Enables circuit breaker switching off by shunt trip also at interruption of power supply of control circuits (max. 5 min) 230 V a.c./220 V d.c. 3WL9111-0BA14-0AA0 36099 Enables circuit breaker switching off by shunt trip also at interruption of power supply of control circuits (max. 5 min) - operating voltage of the source must be identical to the operating voltage of the shunt trip Weight [kg] 0.500 Package [pcs] 1 0.500 1 Bowden cables for mechanical blocking Length 2m 3m 4.5 m Type 3WL9111-0BB45-0AA0 3WL9111-0BB46-0AA0 3WL9111-0BB47-0AA0 Product code 36684 36685 36686 Weight [kg] 0.160 0.250 0.350 Package [pcs] 1 1 1 Overcurrent release Type ETU15B, ETU25B, ETU27B, ETU45B 3WL9111-0AT45-0AA0 ETU76B 3WL9111-0AT46-0AA0 Product code 19421 19422 Weight [kg] 0.050 0.050 Package [pcs] 1 1 NSE00983 Sealable covers of overcurrent release ETU25B Rating Plug TEST QUERY CLEAR Door sealing frames Type 3WL9111-0AP01-0AA0 Product code 13959 Description Degree of protection IP41 Weight [kg] 0.630 Package [pcs] 1 Type 3WL9111-0AP02-0AA0 Product code 20516 Description Weight [kg] Degree of protection IP55 1.600 - the cover cannot be used simultaneously with the sealing frame - the cover can be removed - the cover can be opened to both sides Package [pcs] 1 NSE01020 NSE01028 Transparent covers Arc chute covers NSE01008 Design, size Type Product code 3-pole, size I 3WL9111-0AS32-0AA0 19335 3-pole, size II 3WL9111-0AS36-0AA0 19336 3-pole, size III 3WL9111-0AS38-0AA0 19337 4-pole, size I 3WL9111-0AS42-0AA0 19338 4-pole, size II 3WL9111-0AS44-0AA0 19339 4-pole, size III 3WL9111-0AS46-0AA0 19340 - installation is not possible for 1000/1150 V (code „A05“, „A15“) and DC switch-disconnectors Weight [kg] 1.830 2.600 4.050 2.340 3.300 5.210 Package [pcs] 1 1 1 1 1 1 Type Weight [kg] 4.800 Package [pcs] 1 Bearing angles Product code 34771 Description For installation of fixed circuit breaker on vertical plane, only for size I and II - contains 2 pieces NSE-01022 NSE-01022 3WL9111-0BB50-0AA0 In your order always state both type designation and product code, if any. 37 Arion Commercial information 3P 4P ACCESSORIES - FOR ADDITIONAL INSTALLATION BY OEZ SERVICE NSE00972 Connections for withdrawable device - rear vertical connection Size I I II II II III III Rated current 1000 A 2000 A 2000 A 2500 A 3200 A 5000 A 6300 A Type 3WL9111-0AN15-0AA0 3WL9111-0AN16-0AA0 3WL9111-0AN17-0AA0 3WL9111-0AN18-0AA0 3WL9111-0AN21-0AA0 3WL9111-0AN22-0AA0 3WL9111-0AN23-0AA0 Product code 19359 19360 19361 19362 19363 19364 19365 Description Upper or lower terminal Upper or lower terminal Upper or lower terminal Upper or lower terminal Upper or lower terminal Upper or lower terminal Upper or lower terminals, 3 pcs (for 3-pole design) Upper or lower terminals, 4 pcs (for 4-pole design) Upper or lower terminals, 4 pcs (for 4-pole design) Weight [kg] 0.570 0.800 1.100 1.400 2.500 6.000 20.000 Package [pcs] 1 1 1 1 1 1 1 3WL9111-0AN20-0AA0 19366 20.000 1 3WL9111-0AN10-0AA0 36065 20.000 1 Type 3WL9111-0AN32-0AA0 3WL9111-0AN33-0AA0 3WL9111-0AN34-0AA0 3WL9111-0AN35-0AA0 3WL9111-0AN36-0AA0 3WL9111-0AN37-0AA0 Product code 36072 36073 36074 15991 36075 36076 Description Upper or lower terminal Upper or lower terminal Upper or lower terminal Upper or lower terminal Upper or lower terminal Upper or lower terminal Weight [kg] 0.63 0.77 1.02 1.24 2.17 3.86 Package [pcs] 1 1 1 1 1 1 Type 3WL9111-0AN24-0AA0 3WL9111-0AN25-0AA0 3WL9111-0AN26-0AA0 3WL9111-0AN27-0AA0 3WL9111-0AN28-0AA0 3WL9111-0AN31-0AA0 Product code 36066 36067 36068 36069 36070 36071 Description Upper or lower terminal Upper or lower terminal Upper or lower terminal Upper or lower terminal Upper or lower terminal Upper or lower terminal Weight [kg] 0.61 0.64 0.98 1.02 1.31 2.37 Package [pcs] 1 1 1 1 1 1 NSE00967 Connections for withdrawable device - rear horizontal connection Size I I II II II III Rated current 1000 A 2000 A 2000 A 2500 A 3200 A 5000 A NSE00973 Connections for withdrawable device - flanged connection 38 Size I I II II II III Rated current 1000 A 2000 A 2000 A 2500 A 3200 A 4000 A Arion Commercial information 3P 4P ACCESSORIES - FOR ADDITIONAL INSTALLATION BY OEZ SERVICE NSE00983 Overcurrent releases ETU25B Rating Plug TEST QUERY Name ETU15B ETU25B ETU27B ETU45B Protective functions LI LSI LSING LSIN(G) ETU76B LSIN(G) Type 3WL9311-5AA00-0AA2 3WL9312-5AA00-0AA2 3WL9312-7AA00-0AA2 3WL9314-5AA00-0AA2 3WL9314-5AA20-0AA2 3WL9317-6AA00-0AA2 3WL9317-6AA20-0AA2 Product code 36674 36675 36676 36677 36678 36679 36680 Description Without measuring function Plus With measuring function Plus Without measuring function Plus With measuring function Plus Weight [kg] 0.72 0.72 0.72 0.72 Package [pcs] 1 1 1 1 0.72 1 CLEAR Displays Type 3WL9111-0AT81-0AA0 Product code 33713 Description For ETU 45B, number of lines 4, LCD Weight [kg] 0.3 Package [pcs] 1 Type 3WL9111-0AT53-0AA0 3WL9111-0AT56-0AA0 Product code 36088 36089 Description Only for ETU45B, signalling and breaking function Only for ETU76B, signalling and breaking function Weight [kg] 0.03 0.03 Package [pcs] 1 1 Weight [kg] 0.100 1.0 Package [pcs] 1 1 Earth fault modules GFM AT 45B SI g TRIP G OFF ALARM A B C D E ALARM t g (s) TRIP .5 .4 .3 .2 .1 I 2 tg .1 .2 .3 .4 .5 NSE 01027 Terminal blocks and connectors Name Connector Connector NSE00978 3WL9111-0AB01-0AA0 3WL9111-0AB03-0AA0 Product code Description Blade contacts, Ue = 690 V 14535 For circuit breaker s Ue = 1000 V including blade 36041 contact unit for circuit breaker (need not be ordered separately), use at configuring of a new circuit breaker Connector 3WL9111-0AB02-0AA0 36040 For circuit breaker s Ue = 1000 V (blade contact unit for the circuit breaker must be ordered separately, unless it is not on the circuit breaker), use at circuit breaker reconstruction from Ue = 690 V to 1000 V 0.15 1 Terminal block 3WL9111-0AB03-0AA0 3WL9111-0AB04-0AA0 14534 21232 Screw terminals, for circuit breaker or withdrawable device Spring terminals, for circuit breaker or withdrawable device 0.070 1 Terminal block Terminal block 3WL9111-0AB08-0AA0 3WL9111-0AB18-0AA0 19321 36042 Sliding contacts, for withdrawable device 0.100 0.12 1 1 Blinding unit Keying set 3WL9111-0AB12-0AA0 3WL9111-0AB07-0AA0 35915 14544 For circuit breaker 0.03 0.001 1 1 Weight [kg] 1.510 1.510 1.510 1.510 Package [pcs] 1 1 1 1 Weight [kg] 0.700 0.700 0.700 0.700 0.700 0.700 0.700 0.700 0.700 0.700 Package [pcs] 1 1 1 1 1 1 1 1 1 1 NSE00975 3WL9111-0AB04-0AA0 3WL9111-0AB08-0AA0 NSE00977 NSE00976 Type 3WL9111-0AB01-0AA0 3WL9111-0AB10-0AA0 Sliding contacts, including terminal block, screw terminals For circuit breaker in fixed design Motor drives I Operating voltage 24 ÷ 30 V d.c. 48 ÷ 60 V d.c. 110 V a.c./d.c. 230 V a.c./220 V d.c. Type 3WL9111-0AF01-0AA0 3WL9111-0AF02-0AA0 3WL9111-0AF03-0AA0 3WL9111-0AF04-0AA0 Product code 19316 36053 19317 19318 Operating voltage 24 V d.c. 30 V d.c. 48 V d.c. 60 V d.c. 110 V a.c./d.c. 230 V a.c./220 V d.c. 24 V d.c. 48 V d.c. 110 V a.c./d.c. 230 V a.c./220 V d.c. Type 3WL9111-0AD01-0AA0 3WL9111-0AD02-0AA0 3WL9111-0AD03-0AA0 3WL9111-0AD04-0AA0 3WL9111-0AD05-0AA0 3WL9111-0AD06-0AA0 3WL9111-0AD11-0AA0 3WL9111-0AD12-0AA0 3WL9111-0AD13-0AA0 3WL9111-0AD14-0AA0 Product code 19322 36043 36044 34805 19323 19324 36045 36046 36047 14671 NSE01003 Closing releases / shunt trips Description Load factor 100 % Load factor 100 % Load factor 100 % Load factor 100 % Load factor 100 % Load factor 100 % Load factor 5 % Load factor 5 % Load factor 5 % Load factor 5 % 39 Arion Commercial information 3P 4P ACCESSORIES - FOR ADDITIONAL INSTALLATION BY OEZ SERVICE Undervoltage releases Operating voltage 24 V d.c. 30 V d.c. 48 V d.c. 60 V d.c. 110 V a.c./d.c. 230 V a.c./220 V d.c. 400 V d.c. 48 V d.c. 110 V a.c./d.c. 230 V a.c./220 V d.c. 400 V a.c. Type 3WL9111-0AE01-0AA0 3WL9111-0AE02-0AA0 3WL9111-0AE03-0AA0 3WL9111-0AE07-0AA0 3WL9111-0AE04-0AA0 3WL9111-0AE05-0AA0 3WL9111-0AE06-0AA0 3WL9111-0AE11-0AA0 3WL9111-0AE12-0AA0 3WL9111-0AE13-0AA0 3WL9111-0AE14-0AA0 Product code 19325 36048 36049 36673 14665 19326 34799 36050 36051 19327 36052 Description Delay 80 or 200 ms Delay 80 or 200 ms Delay 80 or 200 ms Delay 80 or 200 ms Delay 80 or 200 ms Delay 80 or 200 ms Delay 80 or 200 ms Delay 0.2 ÷ 3.2 s Delay 0.2 ÷ 3.2 s Delay 0.2 ÷ 3.2 s Delay 0.2 ÷ 3.2 s Weight [kg] 0.730 0.730 0.730 0.730 0.730 0.730 0.730 0.740 0.730 0.730 0.730 Package [pcs] 1 1 1 1 1 1 1 1 1 1 1 Auxiliary switches Type 3WL9111-0AG01-0AA0 3WL9111-0AG02-0AA0 3WL9111-0AG03-0AA0 Product code 19328 19329 14608 Description For main contact state signalling, 2NO + 2NC For main contact state signalling, 2NO For main contact state signalling, 1NO + 1NC Weight [kg] 0.180 0.050 0.050 Package [pcs] 1 1 1 Type 3WL9111-0AH01-0AA0 Product code 14609 Description For „Ready-to-close“ state signalling Weight [kg] 0.025 Package [pcs] 1 3WL9111-0AH02-0AA0 17867 0.03 1 3WL9111-0AH14-0AA0 16492 0.03 1 3WL9111-0AH08-0AA0 13957 0.030 1 3WL9111-0AH11-0AA0 19334 0.200 1 3WL9111-0AH12-0AA0 36054 0.4 1 Weight [kg] 0.100 Package [pcs] 1 0.150 0.14 0.14 0.14 0.1 1 Signal switches 3WL9111-0AH11-0AA0 NSE00996 For 1st or 2nd auxiliary release - cannot be combined with codes „F01“, „F02“ a „F12“ - the circuit breaker must be equipped with connector X7 For „Switched off by overcurrent release“ - cannot be combined with codes „F01“, „F02“ a „F12“ - the circuit breaker must be equipped with connector X7 For storage device state signalling - cannot be combined with codes „F01“, „F02“ a „F12“ - the circuit breaker must be equipped with connector X7 For position signalling in the withdrawable device variant 1 - 3 microswitches For position signalling in the withdrawable device variant 2 - 6 microswitches Display and control devices 3WL9111-0AH07-0AA0 3WL9111-0BA72-0AA0 NSE00985 40 Name Counter of cycles Type Product code Description 3WL9111-0AH07-0AA0 14667 Possible only in combination with motor drive Button - cannot be combined 3WL9111-0AJ02-0AA0 with codes „F01“, „F02“, „F12“ 3WL9111-0AJ03-0AA0 a „S25“ 3WL9111-0AJ04-0AA0 3WL9111-0AJ05-0AA0 Switch 3WL9111-0AJ06-0AA0 14668 35973 36055 36056 36057 Button 17871 3WL9111-0BA72-0AA0 For electrical ON with sealable cap For electrical ON, lock CES For electrical ON, lock BKS For electrical ON, lock IKON Cannot be combined with electrical ON push-button, possible only in combination with motor drive Mushroom push-button instead of mechanical OFF push-button 0.08 1 Commercial information Arion 3P 4P ACCESSORIES - FOR ADDITIONAL INSTALLATION BY OEZ SERVICE Data communication devices and measuring function 1 2 3 4 5 6 7 8 9 Device PROFIBUS DP CubicleBus Name Data communication devices Type Product code Description 3WL9111-0AT12-0AA0 20683 Complete data communication PROFIBUS - COM15 module, BSS module, connecting cables 2 m 3WL9111-0AT14-0AA0 3WL9111-0AT17-0AA0 36698 36699 3WL9111-0AT15-0AA0 36084 3WL9111-0AT16-0AA0 3WL9111-0AT04-0AA0 36085 36688 NSE-01025 Data communication devices BSS module Data communication devices Complete data communication MODBUS MODBUS data communication module COM16, cable length 2 m PROFIBUS data communication module COM15, cable length 2 m Circuit breaker status sensor Measuring function PLUS module, without measuring voltage transformers - the transformers shall be ordered see page 40 Weight [kg] 0.5 Package [pcs] 1 0.26 0.14 1 1 0.14 1 0.12 0.25 1 1 - circuit breaker must be equipped at least with ETU45B Internal measuring current transformers for N conductor Size I II III Type 3WL9111-0AA11-0AA0 3WL9111-0AA12-0AA0 3WL9111-0AA13-0AA0 Product code 36037 36038 36039 Weight [kg] 0.5 0.5 0.5 Package [pcs] 1 1 1 Name Noise suppressing filter Type 3WL9111-0AK32-0AA0 Product code Description Weight [kg] 34404 Filtr for interference suppression, contains attenuation 0.300 (asymmetric) filter - attenuation in the range 40 kHz ÷ 10 MHz > 40 dB - application e.g. in IT networks or for frequency converters Package [pcs] 1 NSE00990 EMC noise suppressing filters Remote reset devices Operating voltage Type Product code 24 V d.c. 3WL9111-0AK03-0AA0 36059 48 V d.c. 3WL9111-0AK04-0AA0 36060 110 V a.c./d.c. 3WL9111-0AK05-0AA0 36061 230 V a.c./220 V d.c. 3WL9111-0AK06-0AA0 36062 - can be used only in combination with automatic reset Description Remote reset of the indication push-button „switched off by overcurrent release“ Weight [kg] 0.2 0.2 0.2 0.2 Package [pcs] 1 1 1 1 Weight [kg] 0.05 Package [pcs] 1 Automatic reset devices Type 3WL9111-0AK01-0AA0 Product code 36058 Description Circuit breaker reclosing blocking after its switching off by overcurrent release 41 Arion Commercial information 3P 4P ACCESSORIES - FOR ADDITIONAL INSTALLATION BY OEZ SERVICE Mechanical interlockings NSE00989 Type 3WL9111-0BB21-0AA0 3WL9111-0BB22-0AA0 3WL9111-0BB23-0AA0 Product code 19330 36123 20604 Description For circuit breaker in fixed design, Bowden cable 2 m Only for withdrawable device, Bowden cable 2 m Only for circuit breaker in withdrawable design For circuit breaker in withdrawable design and withdrawable device, Bowden cable 2 m Adapter, only for circuit breaker in withdrawable design - size 3 Weight [kg] 2.320 1.1 1 Package [pcs] 1 1 1 3WL9111-0BB24-0AA0 19331 2.420 1 3WL9111-0BB30-0AA0 36124 1.1 1 Type 3WL9111-0BA21-0AA0 Product code 17408 Description Against unauthorized mechanical ON/OFF, set for padlocks Weight [kg] 0.300 Package [pcs] 1 3WL9111-0BA22-0AA0 3WL9111-0BA24-0AA0 19332 36100 Against unauthorized mechanical ON/OFF, lock CES Against unauthorized mechanical ON/OFF, lock IKON 0.24 0.3 1 1 3WL9111-0BA31-0AA0 19333 Against unauthorized ON, set for FORTREES, CASTELL 0.200 1 3WL9111-0BA33-0AA0 3WL9111-0BA34-0AA0 3WL9111-0BA35-0AA0 3WL9111-0BA36-0AA0 3WL9111-0BA38-0AA0 3WL9111-0BA41-0AA0 36101 36102 36103 36104 36105 21213 Against unauthorized ON, lock RONIS Against unauthorized ON, lock KIRK-Key Against unauthorized ON, lock PROFALUX Against unauthorized ON, lock CES Against unauthorized ON, lock IKON Against unauthorized ON, set for padlocks 0.45 0.27 0.25 0.2 0.2 0.5 1 1 1 1 1 1 3WL9111-0BA51-0AA0 36107 0.3 3WL9111-0BA53-0AA0 36108 3WL9111-0BA57-0AA0 36109 3WL9111-0BA58-0AA0 36110 3WL9111-0BA50-0AA0 36106 Against unauthorized ON, for circuit breaker in withdrawable design, lock CES Against unauthorized ON, for circuit breaker in withdrawable design, lock IKON Against unauthorized ON, for circuit breaker in withdrawable design, lock KIRK-Key Against unauthorized ON, for circuit breaker in withdrawable design, lock RONIS Against unauthorized ON, for circuit breaker in withdrawable design, lock PROFALUX 3WL9111-0BA71-0AA0 14666 For storage device lever, set for padlocks 3WL9111-0BA73-0AA0 3WL9111-0BA75-0AA0 3WL9111-0BA76-0AA0 3WL9111-0BA77-0AA0 3WL9111-0BA80-0AA0 36111 36112 36113 36114 36115 3WL9111-0BA81-0AA0 3WL9111-0BA83-0AA0 3WL9111-0BA85-0AA0 3WL9111-0BA86-0AA0 3WL9111-0BA43-0AA0 Locking devices NSE00980 3WL9111-0BA2-0AA0 3WL9111-0BA3-0AA0 NSE00981 3WL9111-0BA5-0AA0 NSE00982 3WL9111-0BA71-0AA0 NSE00984 0.3 0.3 0.3 0.3 1 1 1 1 1 0.080 1 Against circuit breaker shifting, lock CES Against circuit breaker shifting, lock IKON PAgainst circuit breaker shifting, lock PROFALUX Against circuit breaker shifting, lock RONIS Against circuit breaker shifting, lock KIRK-Key 0.3 0.2 0.3 0.3 0.4 1 1 1 1 1 36116 36117 36118 36119 Against circuit breaker shifting in disconnected position, lock CES Against circuit breaker shifting in disconnected position, lock IKON Against circuit breaker shifting in disconnected position, lock PROFALUX Against circuit breaker shifting in disconnected position, lock RONIS 0.8 0.8 0.8 0.8 1 1 1 1 36682 Against unauthorized ON, lock CES, number of locks 3, number of keys 2 0.36 1 3WL9111-0BA7-0AA0 NSE00986 3WL9111-0BA8-0AA0 NSE00987 42 Commercial information Arion 3P 4P ACCESSORIES - FOR ADDITIONAL INSTALLATION BY OEZ SERVICE Blocking devices Type Product code Description 3WL9111-0BB12-0AA0 36120 Against switchboard door opening, for circuit breaker in fixed design Weight [kg] 0.6 Package [pcs] 1 3WL9111-0BB13-0AA0 36121 Against switchboard door opening, for circuit breaker in withdrawable design 0.15 1 3WL9111-0BB15-0AA0 36122 Against shifting of the circuit breaker at opened switchboard door 0.15 1 43 Arion Commercial information 3P 4P ACCESSORIES - FOR ADDITIONAL INSTALLATION BY OEZ SERVICE Insulation covers Number of pole 3 - pól 3 - pól 3 - pól 4 - pól 4 - pól 4 - pól Size I II III I II III Type 3WL9111-0AP04-0AA0 3WL9111-0AP06-0AA0 3WL9111-0AP07-0AA0 3WL9111-0AP08-0AA0 3WL9111-0AP11-0AA0 3WL9111-0AP12-0AA0 Product code 19374 19375 19376 19377 19378 19379 Weight [kg] 0.500 0.630 0.860 0.600 0.770 1.070 Package [pcs] 1 1 1 1 1 1 Operating voltage 690 V 690 V 690 V 1000/1150 V 1000/1150 V Size I II III II III Type 3WL9111-0AS01-0AA0 3WL9111-0AS02-0AA0 3WL9111-0AS03-0AA0 3WL9111-0AS05-0AA0 3WL9111-0AS06-0AA0 Product code 36078 36079 36080 36081 36082 Weight [kg] 1.83 2.6 4.05 2.34 3.3 Package [pcs] 1 1 1 1 1 Description For withdrawable circuit breaker For withdrawable circuit breaker For withdrawable circuit breaker For withdrawable circuit breaker For withdrawable circuit breaker For withdrawable circuit breaker For withdrawable device For withdrawable device Weight [kg] 1.25 1.53 2.27 1.5 1.85 2.95 0.33 0.35 Package [pcs] 1 1 1 1 1 1 1 1 Description Weight [kg] Package [pcs] 0.4 1 Weight [kg] 5.1 5.9 8.1 6.4 6.45 10.7 Package [pcs] 1 1 1 1 1 1 NSE01007 Arc chutes Earthing devices NSE01019 Number of pole Size Type Product code 3 - pole I 3WL9111-0BA05-0AA0 36093 3 - pole II 3WL9111-0BA06-0AA0 36094 3 - pole III 3WL9111-0BA07-0AA0 36095 4 - pole I 3WL9111-0BA08-0AA0 36096 4 - pole II 3WL9111-0BA04-0AA0 36092 4 - pole III 3WL9111-0BA10-0AA0 36097 3 - pole, 4 - pole I, II 3WL9111-0BA01-0AA0 36090 3 - pole, 4 - pole III 3WL9111-0BA02-0AA0 36091 - contact module making capacity is 30 kA, at use of two modules 60 kA Coding of withdrawable device Type 3WL9111-0AR12-0AA0 Kód výrobku 36077 Number of variants 36 NSE01009 Sets for reconstruction of fixed design to withdrawable design Number of pole Size Type Product code 3 - pól I 3WL9111-0BC11-0AA0 36125 3 - pól II 3WL9111-0BC12-0AA0 36126 3 - pól III 3WL9111-0BC13-0AA0 36127 4 - pól I 3WL9111-0BC14-0AA0 36128 4 - pól II 3WL9111-0BC15-0AA0 36129 4 - pól III 3WL9111-0BC16-0AA0 36130 - withdrawable device and sliding contacts shall be ordered separately Main contacts NSE-01021 44 Size Rated current Type Product code Weight [kg] Package [pcs] I 1600 A 3WL9111-0AM901Y 34405 2.8 1 II 2500 A 3WL9111-0AM911Y 34406 5.87 1 II 4000 A 3WL9111-0AM921Y 34407 7.7 1 III 6300 A 3WL9111-0AM931Y 34408 13.74 1 - in the order it is necessary to specify the serial number of the circuit breaker, the type is changed automatically in the order depending on the serial number - 3 or 4 pcs are ordered according to the number of poles Air circuit breakers Arion CONTENT – Technical information CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Specifications..............................................................................................................................................................46 Diagram ......................................................................................................................................................................51 Connection..................................................................................................................................................................53 Description..................................................................................................................................................................55 Dimensions .................................................................................................................................................................56 WITHDRAWABLE DEVICES Description..................................................................................................................................................................69 OVERCURRENT RELEASES Description..................................................................................................................................................................71 Overview of parameters..............................................................................................................................................72 ETU15B - description, tripping characteristic ..............................................................................................................74 ETU25B - description, tripping characteristic ..............................................................................................................75 ETU27B - description, tripping characteristic ..............................................................................................................76 ETU45B - description, tripping characteristic ..............................................................................................................77 ETU75B - description, tripping characteristic ..............................................................................................................79 EARTH FAULT MODULES Description..................................................................................................................................................................81 MEASURING AND DATA COMMUNICATION Description..................................................................................................................................................................82 AUXILIARY SWITCHES, SIGNAL SWITCHES Description, specifications ..........................................................................................................................................85 SHUNT TRIPS, AUXILIARY POWER SOURCES FOR SHUNT TRIP Description, specifications...........................................................................................................................................86 UNDERVOLTAGE RELEASES Description, specifications...........................................................................................................................................86 LOCKING AND BLOCKING DEVICES Description..................................................................................................................................................................87 DRIVES AND CLOSING RELEASES Description, specifications...........................................................................................................................................88 GLOSSARY..........................................................................................................................................................................89 CONTENT – Commercial information see page 1 45 Arion Technical information 3P 4P CIRCUIT BREAKERS, SWITCH-DISCONNECTORS - AC OPERATION Specifications Type ARION WL11... ARION WL12... ARION WL13... Size I II III Standards EN 60947-2 EN 60947-2 EN 60947-2 IEC 60947-2 IEC 60947-2 IEC 60947-2 DIN VDE 0660 Section 101 DIN VDE 0660 Section 101 DIN VDE 0660 Section 101 Approval marks Number of poles 3, 4 3, 4 3, 4 Rated current In 630 A 800 A 1000 A 1250 A 1600 A 2000 A 800 A 1000 A 1250 A 1600 A 2000 A 2500 A 3200 A 4000 A 4000 A 5000 A 6300 A Rated operating voltage Ue 690 V a.c. 690 V a.c. 1000 V a.c. 3) 1150 V a.c. 3) 690 V a.c. 1000 V a.c. 3) 1150 V a.c. 3) Rated frequency fn 50/60 Hz 50/60 Hz 50/60 Hz 12 kV Size I Rated impulse voltage - main current path Size II Uimp 12 kV 12 kV - auxiliary circuits 4 kV 4 kV 4 kV - control circuits 2.5 kV 2.5 kV 2.5 kV 1000 V/1150 V a.c. 1000 V/1150 V a.c. 1000 V/1150 V a.c. B B B Rated insulation voltage Ui Utilization category (selectivity) Rated short-time withstand current Icw see the table on page 47 see the table on page 47 see the table on page 47 Rated short-circuit ultimate breaking capacity Icu see the table on page 47 see the table on page 47 see the table on page 47 Rated short-circuit service breaking capacity Ics Rated short-circuit making capacity Icm 100 % Icu 50 ms 1) Time to switching off at Icu Size III 100 % Icu 50 ms 1) 50 ms 1) Mechanical switching on time 35 ms 35 ms 35 ms Mechanical switching off time 38 ms 34 ms 34 ms Power loss at In Switching frequency see the table on page 48 see the table on page 48 see the table on page 48 Ue = 690 V a.c. (1000 V a.c.) Minimum dwell between circuit breaker switching off by overcurrent release and subsequent reclosing Degree of protection Ambient temperature range 60 cycles/h (20) 80 ms 2) 80 ms 2) 40 °C 40 °C -25 °C ÷ +70 °C -25 °C ÷ +70 °C -25 °C ÷ +70 °C -40 °C ÷ +70 °C -40 °C ÷ +70 °C -40 °C ÷ +70 °C 2000 m 2000 m 2000 m IEC 68 section 30-20 IEC 68 section 30-20 IEC 68 section 30-20 operation Sea level Climatic resistance Weight 60 cycles/h (20) 80 ms 2) 40 °C (it is necessary to observe special conditions for LCD) storage 1) 60cycles/h IP20, IP41 with sealing frame, IP55 with transparent cover Reference ambient temperature m see the table on page 48 see the table on page 48 see the table on page 48 With ETU15B switching off time is 85 ms. 2) Only with automatic reset of reclosing blocking. 3) Special design see page 27. Circuit breakers size III with Icu = H can operate in IT networks up to 690 V a.c. 46 100 % Icu see the table on page 47 see the table on page 47 see the table on page 47 Arion Technical information 3P 4P CIRCUIT BREAKERS, SWITCH-DISCONNECTORS - AC OPERATION Specifications Rated short-time withstand current Icw 2) Size - Type I – ARION WL11… II – ARION WL12… Designation of breaking capacity N S H N S H - In <= 2500 A 0.5 s 50 kA 66 kA 75 kA 66 kA 80 kA 85 kA 1s 42 kA 50 kA 66 kA 55 kA 66 kA 80 kA 2s 29,5 kA 35 kA 46 kA 39 kA 46 kA 65 kA 3s 24 kA 29 kA 37 kA 32 kA 37 kA 50 kA 1) Values in N-pole = 60 %. 2) At reverse connection the values do not change (input terminals 2, 4, 6, output terminals 1, 3, 5). III – ARION WL13…1) H C 100 kA 100 kA 100 kA 100 kA 80 kA 80 kA 65 kA 65 kA H - In = 3200 A 100 kA 80 kA 70 kA 65 kA Rated short-circuit ultimate breaking capacity Icu 2) Size - Type I – ARION WL11… II – ARION WL12… III – ARION WL13…1) Designation of breaking capacity N S H N S H H C 415 V a.c., 500 V a.c. 55 kA 66 kA 85 kA 66 kA 80 kA 100 kA 100 kA 150 kA (3-pole), 130 kA (4-pole) 690 V a.c. 42 kA 50 kA 66 kA 50 kA 75 kA 85 kA 85 kA 150 kA (3-pole), 130 kA (4-pole) 1000 V/1150 V a.c. 50 kA 50 kA 50 kA 70 kA 3) 2) 3) 1) Values in N-pole = 60 %. At reverse connection the values do not change (input terminals 2, 4, 6, output terminals 1, 3, 5). Rated operating voltage 1150 V. Rated short-circuit ultimate making capacity Icm 2) Size - Type I – ARION WL11… II – ARION WL12… III – ARION WL13… 1) Designation of breaking capacity N S H N S H H C 415 V a.c., 500 V a.c. 121 kA 145 kA 187 kA 145 kA 176 kA 220 kA 220 kA 330 kA (3-pole), 286 kA (4-pole) 690 V a.c. 88 kA 105kA 145 kA 105 kA 165 kA 187 kA 187 kA 330 kA (3-pole), 286 kA (4-pole) 1000 V/1150 V a.c. 105 kA 105 kA 105 kA 154 kA 3) 1) Values in N-pole = 60 %. 2) At reverse connection the values do not change (input terminals 2, 4, 6, output terminals 1, 3, 5). 3) Rated operating voltage 1150 V. Rated conditional short-circuit current Icc 1) Size - Type I - ARION WL11… II – ARION WL12… Designation of breaking capacity N S H N S H 500 V a.c. 55 kA 66 kA 75 kA 66 kA 80 kA 100 kA 690 V a.c. 42 kA 50 kA 66 kA 50 kA 75 kA 85 kA 1000 V/1150 V a.c. 50 kA 50 kA 2) 1) At reverse connection the values do not change (input terminals 2, 4, 6, output terminals 1, 3, 5). 2) Rated operating voltage 1150 V. III – ARION WL13… H 100 kA 85 kA 50 kA 2) C 100 100 70 kA 2) Mechanical endurance I - ARION WL11… N 10 000 cycles S 10 000 cycles H 10 000 cycles C N 20 000 cycles, 15 000 cycles (2000 A) with maintenance 1) S 20 000 cycles, 15 000 cycles (2000 A) H 15 000 cycles C 1) At replacement of main contacts and arc chutes. without maintenance Electrical endurance Ue 690 V a.c. I - ARION WL11… without maintenance N 10 000 cycles, 7 500 cycles (2000 A) S 10 000 cycles, 7 500 cycles (2000 A) H 7 500 cycles C 20 000 cycles, 15 000 cycles (2000 A) with maintenance 1) N S 20 000 cycles, 15 000 cycles (2000 A) H 15 000 cycles (3P), 10 000 cycles (4P) 1000 V a.c. without maintenance H 1 000 cycles (2000 A) C 1150 V a.c. without maintenance H C 1) At replacement of main contacts and arc chutes. II - ARION WL12… 10 000 cycles 10 000 cycles 10 000 cycles 15 000 cycles 15 000 cycles 15 000 cycles - III - ARION WL13… 5 000 cycles 5 000 cycles 10 000 cycles 10 000 cycles II - ARION WL12… III - ARION WL13… 7 500 cycles, 4 000 cycles (3200 A), 2 000 cycles (4000 A) 7 500 cycles, 4 000 cycles (3200 A), 2 000 cycles (4000 A) 7 500 cycles, 4 000 cycles (3200 A), 2 000 cycles (4000 A) 15 000 cycles 15 000 cycles 15 000 cycles 1000 cycles 500 cycles - 2 000 cycles 1 000 cycles 10 000 cycles 1000 cycles 1000 cycles 500 cycles 500 cycles 47 Arion Technical information CIRCUIT BREAKERS, SWITCH-DISCONNECTORS - AC OPERATION Specifications Losses at In - per 3 pole Type Fixed design ARION WL1106… 100 W ARION WL1108… 100 W ARION WL1110… 100 W ARION WL1112… 105 W ARION WL1116… 170 W ARION WL1120… 240 W ARION WL1208… 40 W ARION WL1210… 45 W ARION WL1212 … 80 W ARION WL1216 … 85 W ARION WL1220… 180 W ARION WL1225… 270 W ARION WL1232… 410 W ARION WL1340… 520 W ARION WL1350… 630 W ARION WL1363… 900 W Withdrawable design 195 W 195 W 195 W 205 W 350 W 440 W 85 W 95 W 165 W 175 W 320 W 520 W 710 W 810 W 1050 W 1600 W Weight Type ARION WL1106… ARION WL1108… ARION WL1110… ARION WL1112… ARION WL1116… ARION WL1120… ARION WL1208… ARION WL1210… ARION WL1212 … ARION WL1216 … ARION WL1220… ARION WL1225… ARION WL1232… ARION WL1340… ARION WL1350… ARION WL1363… 48 Fixed design 43 kg 43 kg 43 kg 43 kg 43 kg 43 kg 56 kg 56 kg 56 kg 56 kg 56 kg 59 kg 64 kg 82 kg 82 kg 90 kg Maximum load of the circuit breaker/switch-disconnector depending on ambient temperature Type 55 °C 60 °C 70 °C ARION WL1106… 630 A 630 A 630 A ARION WL1108… 800 A 800 A 800 A ARION WL1110… 1000 A 1000 A 1000 A ARION WL1112… 1250 A 1250 A 1210 A ARION WL1116… 1600 A 1600 A 1490 A ARION WL1120… 2000 A 1930 A 1780 A ARION WL1208… 800 A 800 A 800 A ARION WL1210… 1000 A 1000 A 1000 A ARION WL1212… 1250 A 1250 A 1250 A ARION WL1216… 1600 A 1600 A 1600 A ARION WL1220… 2000 A 2000 A 2000 A ARION WL1225… 2500 A 2500 A 2280 A ARION WL1232… 3200 A 3020 A 2870 A ARION WL1340… 4000 A 4000 A 4000 A ARION WL1350… 5000 A 5000 A 5000 A ARION WL1363… 5920 A 5810 A 5500 A 3-pole Withdrawable circuit breaker + withdrawable device 45 + 25 = 70 kg 45 + 25 = 70 kg 45 + 25 = 70 kg 45 + 25 = 70 kg 45 + 25 = 70 kg 45 + 25 = 70 kg 60 + 31 = 91 kg 60 + 31 = 91 kg 60 + 31 = 91 kg 60 + 31 = 91 kg 60 + 31 = 91 kg 63 + 39 = 102 kg 68 + 45 = 113 kg 88 + 60 = 148 kg 88 + 60 = 148 kg 70 + 108 = 178 kg 4-pole Fixed design Withdrawable circuit breaker + withdrawable device 50 kg 54 + 30 = 84 kg 50 kg 54 + 30 = 84 kg 50 kg 54 + 30 = 84 kg 50 kg 54 + 30 = 84 kg 50 kg 54 + 30 = 84 kg 50 kg 54 + 30 = 84 kg 67 kg 72 + 37 = 109 kg 67 kg 72 + 37 = 109 kg 67 kg 72 + 37 = 109 kg 67 kg 72 + 37 = 109 kg 67 kg 72 + 34 = 106 kg 71 kg 76 + 47 = 123 kg 77 kg 82 + 54 = 136 kg 99 kg 106 + 84 = 190 kg 99 kg 106 + 84 = 190 kg 108 kg 108 + 119 = 227 kg 3P 4P Arion Technical information 3P 4P SWITCH-DISCONNECTORS - DC OPERATION Specifications Type ARION WL1210-8AA... Size II Standards ARION WL1220-8AA... ARION WL1240-8AA... II II EN 60947-3 EN 60947-3 EN 60947-3 IEC 60947-3 IEC 60947-3 IEC 60947-3 DIN VDE 0660 Section 101 DIN VDE 0660 Section 101 DIN VDE 0660 Section 101 Approval marks Number of poles Size II 3, 4 3, 4 3, 4 Rated current In 1000 A 2000 A 4000 A Rated operating voltage Ue 300 V d.c. 1) 600 V d.c. 1) 1000 V d.c. 1) 2) 300 V d.c. 1) 600 V d.c. 1) 1000 V d.c. 1) 2) 300 V d.c. 1) 600 V d.c. 1) 1000 V d.c. 1) 2) 12 kV Rated impulse voltage - main current path 12 kV 12 kV - auxiliary circuits 4 kV 4 kV 4 kV - control circuits 2.5 kV 2.5 kV 2.5 kV 1000 V/1150 V 1000 V/1150 V 1000 V/1150 V Rated insulation voltage Ui Rated short-time withstand current Icw see the table on page 50 see the table on page 50 see the table on page 50 Rated conditional short-circuit current Icc see the table on page 50 see the table on page 50 see the table on page 50 Mechanical switching on time 35 ms 35 ms 35 ms Mechanical switching off time 34 ms 34 ms 34 ms Power loss at In per 1 pole Mechanical endurance Electrical endurance 280 W 770 W 1640 W - without maintenance 10 000 cycles 10 000 cycles 10 000 cycles - with maintenance 3) 15 000 cycles 15 000 cycles 15 000 cycles - without maintenance 6000 cycles 6000 cycles 4000 cycles 1000 cycles (1000 V d.c.) 1000 cycles (1000 V d.c.) 1000 cycles (1000 V d.c.) - with maintenance 3) Switching frequency Ue = 600 d.c. V (1000 V d.c) 15 000 cycles 15 000 cycles 15 000 cycles 60 cycles/h (20) 60 cycles/h (20) 60 cycles/h (20) Degree of protection IP20, IP41 with sealing frame, IP55 with transparent cover Reference ambient temperature 40 °C Ambient temperature range 40 °C 40 °C operation - 25 °C ÷ + 70 °C - 25 °C ÷ + 70 °C - 25 °C ÷ + 70 °C storage - 40 °C ÷ + 70 °C - 40 °C ÷ + 70 °C - 40 °C ÷ + 70 °C Sea level Climatic resistance Weigh 2000 m 2000 m 2000 m IEC 68 section 30-20 IEC 68 section 30-20 IEC 68 section 30-20 see the table on page 50 see the table on page 50 see the table on page 50 1) Rated operating voltage according to the connection see page 50. 2) Special design see page 27. 3) At replacement of main contacts and arc chutes. For possible protection of DC circuits, please call technical assistance. See the cover sheet for contact. 49 Arion Technical information 3P 4P SWITCH-DISCONNECTORS - DC OPERATION Specifications Rated short-time withstand current Icw 1) Operating voltage Ue Type ARION WL1210-8AA… ARION WL1220-8AA… ARION WL1240-8AA… 300 V d.c. 30 kA/1 s 30 kA/1 s 30 kA/1 s 600 V d.c. 25 kA/1 s 25 kA/1 s 25 kA/1 s 1000 V d.c. 20 kA/1 s 20 kA/1 s 20 kA/1 s 1) At reverse connection of the switch-disconnector the values do not change (input terminals 2, 4, 6, output terminals 1, 3, 5). Rated conditional short-circuit current Icc 1) Operating voltage Ue Type ARION WL1210-8AA… ARION WL1220-8AA… ARION WL1240-8AA… 300 V d.c. 30 kA/1 s 30 kA/1 s 30 kA/1 s 600 V d.c. 25 kA/1 s 25 kA/1 s 25 kA/1 s 1000 V d.c. 20 kA/1 s 20 kA/1 s 20 kA/1 s 1) At reverse connection of the switch-disconnector the values do not change (input terminals 2, 4, 6, output terminals 1, 3, 5). Weight Type 3-pole Withdrawable circuit breaker + withdrawable device 60 + 31 = 91 kg 60 + 31 = 91 kg 68 + 45 = 113 kg Fixed design ARION WL1210-8AA... ARION WL1220-8AA... ARION WL1240-8AA... 56 kg 56 kg 64 kg Rated current versus ambient temperature Type 55 °C ARION WL1210-8AA... 1000 A ARION WL1220-8AA... 2000 A ARION WL1240-8AA... 3640 A 60 °C 1000 A 2000 A 3500 A Fixed design 67 kg 67 kg 77 kg 4-pole Withdrawable circuit breaker + withdrawable device 72 + 37 = 109 kg 72 + 37 = 109 kg 82 + 54 = 136 kg 70 °C 1000 A 1950 A 3250 A Connection of switch-disconnectors for DC operation according to operating voltage Rated operating voltage Recommended number of contacts in series 3-pole switch-disconnectors Operating current up to 4000 A per current path 4-pole switch-disconnectors Operating current up to 4000 A per current path 1-pole switching, 3 current paths parallel only with earthed network 2-pole switching 1-pole switching, 4 current paths parallel only with 2-pole switching earthed network 2 current paths parallel 2-pole switching, only with earthed network 1-pole switching, 2 current paths parallel only with earthed network 2-pole switching 1-pole switching, only with earthed network 2-pole switching, only with earthed network up to 300 V + 10 % over 300 V + 10 % up to 600 V + 10 % over 600 V + 10 % up to 1000 V + 10 % Connection of the switch-disconnector does not depend on polarity. Circuit diagrams can be changed logically. If parallel or serial connections are made directly on the main leads of the circuit breaker, the for thermal reasons the circuit breakers can by permanently loaded only by 80 % of permissible rated current. If these connections are made at 1 m or more from the main leads, the circuit breaker can be loaded by full rated current. 50 Earthed network’ Load 2-pole switching Arion Technical information 3P 4P CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Diagram Internal Remote reset electromagnet F7 Measuring current transformer G, S2 Measuring current transformer G, S1 Measuring current transformer N, S2 Measuring current transformer N, S1 External measuring voltage transformers, node External measuring voltage transformers, L3 External measuring voltage transformers, L2 External measuring voltage transformers, L1 ETU CubicleBUS + CubicleBUS – Storage device state signalling S21 Electrical “ON” push-button on the circuit breaker S10 Signal switch for the 1st auxiliary release, S22 Signal switch for the 2nd auxiliary release, S23 X6 14 13 12 11 10 9 8 7 6 5 4 3 2 1 First auxiliary release F1 - shunt Auxiliary make contact S1 Auxiliary break contact S1 Closing release Y1 Signal switch „ready-to-close” S20 Auxiliary make contact S2 Auxiliary break contact S2 Second auxiliary release F2 - shunt or F3 - undervoltage or F4 - undervoltage with delay Auxiliary make contact S3 or make S7 Auxiliary make contact S3 or make S7 Auxiliary make contact S4 nor make S8 Auxiliary make contact S4 or make S8 M External X8 14 13 12 11 10 9 8 7 6 5 4 3 2 1 X7 14 13 12 11 10 9 8 7 6 5 4 3 2 1 Signal switch „switched off by overcurrent release“ S24 Motor drive storage device Storage device motor drive switch S12 Terminals X5 14 13 12 11 10 9 8 7 6 5 4 3 2 1 L / L+ N / L− Jumper, if measuring current transformer N is not connected L1 L2 L3 - 24 V DC input + Terminating resistor, if no CubicleBUS module is connected (the resistor is included in the delivery) COM 15 nebo COM 16 COM 15 - MODBUS data communication module COM 16 - PROFIBUS data communication module L / L+ L / L+ N / L− Electrical “OFF” push-button L / L− N / L+ Electrical “ON” push-button Emergency OFF” push-button or jumper - only for undervoltage release delayed L / L+ N / L− L / L+ N / L− 51 Arion Technical information 3P 4P CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Diagram Example of control circuit connection B L1 (L+) L1 (L+) OFF -S10 L elektr. electrical ONON -X5.6 -X5.4 -X5.10 -X5.8 -X6.4 -X6.2 -X6.12 -X6.10 5 N 1 3 -X6.6 -X7.12 -X7.14 -X5.12 -X6.14 -X6.7 -X7.9 -X5.2 ON ETU S I N N G -S11 -T2 -T3 N (L-) -X5.5 -X5.3 -X5.9 -X5.7 -X6.3 -X6.1 -X6.9 6 -X6.11 -X8.9 * -X8.10 -X6.5 -X7.13 -T4 -X5.11 -X6.13 -X6.8 -F1 N 2 4 -S12 U< NSE0_01558a_oe -F3 -Y1 -X5.1 -S4 -S3 -T1 M N (L-) -S2 -S1 -Q1 P QS mech. mechanical ON ON mechanical mech. OFF OFF -S24 -F5 -S20 R * Jumper, if measuring current transformer is not connected. Diagram description T1, T2, T3 - current transformers Q1 - main contacts ETU - overcurrent release at the circuit breaker, switch-disconnector is without overcurrent release S1, S2, S3, S4 - auxiliary switches F1 - 1st auxiliary release – shunt trip F3 - 2nd auxiliary release – undervoltage release F5 - voltage coil – controlled by overcurrent release Y1 - closing release S10 - switch for electrical closing S12 - storage device motor drive switch S20 - signal switch “ready-to-close” S24 - signal switch „switched off by overcurrent release“ – it can only be at the circuit breaker P - storage device M - motor R - indication and reset push-button on the overcurrent release – signals switching off by overcurrent release QS - storage device lever electrical ON - push-button for electrical ON on the front panel of the circuit breaker mechanical ON - push-button for mechanical ON B - recommended wiring of the control circuits – not part of the circuit breaker/switch-disconnector - ON – push-button for electrical remote switching on - OFF – push-button for electrical remote switching off 52 Arion Technical information 3P 4P CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Connection and installation Recommended dimensions of main connections and min. cross-sections Type ARION WL1106... ARION WL1108... ARION WL1110... ARION WL1112... ARION WL1116... ARION WL1120... ARION WL1208... ARION WL1212 ... ARION WL1216... ARION WL1220... ARION WL1225... ARION WL1232... ARION WL1340... ARION WL1350... ARION WL1363... Dimensions Cu busbars [mm] 1x 60 x 10 1x 60 x 10 1x 60 x 10 2x 50 x 8 2x 50 x 10 3x 50 x 10 1x 80 x 8 2x 80 x 5 2x 80 x 8 4x 80 x 5 3x 80 x 8 4x 80 x 10 4x 120 x 10 5x 120 x 10 6x 120 x 10 Min. cross-section [mm2] 600 600 600 800 1000 1500 500 800 1000 1500 2000 3000 4000 6000 7200 Main (power) circuit - is connected by Cu busbars - to extend connection options, use connecting sets see „types of main connections“ - reverse connection is possible (inversion of input and output terminals) without limitation of rated ultimate short-circuit breaking capacity Icu - we recommend to coat the busbars with paint - input and output conductors/busbars must be reinforced mechanically to eliminace transfer of electrodynamic forces into circuit breaker/switch-disconnector at short-circuits see fig. Rear horizontal connection Rear vertical connection Rear flanged connection Front connection one series of holes Front connection two series of holes Rear horizontal connection Front connection one series of holes - custom delivery Front connection two series of holes NSE00979 NSE00969 NSE00968 NSE00967 Types of main connections Fixed design Rear vertical connection Rear horizontal connection Front connection one series of holes - custom delivery Front connection two series of holes Rear vertical connection NSE00973 NSE00972 NSE00971 NSE00970 NSE00967 Withdrawable design Rear flanged connection - custom delivery 53 Arion Technical information 3P 4P CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Connection and installation Terminal blocks and connectors The delivered circuit breaker/switch-disconnector is always equipped with all connectors and terminal blocks for connection of selected auxiliary circuits. Fixed design Withdrawable design Terminal block 3WL9111-0AB03-0AA0 Terminal block 3WL9111-0AB04-0AA0 NSE00978 NSE00977 Terminal block 3WL9111-0AB04-0AA0 NSE00975 NSE00976 NSE00975 Terminal block 3WL9111-0AB03-0AA0 NSE00976 or or NSE00978 Connector 3WL9111-0AB01-0AA0 Connector 3WL9111-0AB01-0AA0 Connecting cross-sections of conductors of auxiliary circuits Conductor type Terminal type Cu stranded wire without sleeve Cu stranded wire with sleeve (DIN 46 228 T.2) Cu stranded wires with double sleeve (DIN 46 228 T.2) 54 Screw terminals 2x 0.5 mm2 ÷ 2x 1.5 mm2 , 1x 2.5 mm2 1x 0.5 mm2 ÷ 1x 1.5 mm2 2x 0.5 mm2 ÷ 2x 1.5 mm2 Spring terminals 2x 0.5 mm2 ÷ 2x 2.5 mm2 2x 0.5 mm2 ÷ 2x 1.5 mm2 - Terminal block 3WL9111-0AB08-0AA0 Technical information Arion 3P 4P CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Description of circuit breaker, switch-disconnector Circuit breaker (1) (1) (28) (28) (2) (2) (27) (27) (26) (26) (3) (3) (4) (4) (25) (25) (5) (5) (24) (24) (6) (6) (23) (23) (7) (7) (22) (22) (21) (21) (8) (8) (9) (20) (20) (9) (10) (10) (11) (11) (19) (19) (18) (18) (17) (17) (12) (12) (13) (13) (16) (16) (14) (14) (15) NSE00965 (15) 1 Arc chutes 2 Transport handle 3 Label for description by the user 4 Optional storage device motor drive switch or push-button „electrical ON“ 5 Label with circuit breaker parameters (rated values) 6 Mechanical storage device state 7 Push-button „mechanical ON“ 8 Value of rated current of circuit breaker 9 Pictogram of instructions for withdrawable circuit breaker handling (for withdrawable design only) 10 Operating cycle counter (optional) 11 Storage device hand drive lever 12 Crank for withdrawing/inserting (for withdrawable design only) 13 Shaft of withdrawable circuit breaker shifting (for withdrawable design only) 14 Label with data of circuit breaker equipment 15 Hole for protective earthing 16 Indication of circuit breaker position in the withdrawable device 17 Table with data of earth fault protection 18 Locking device against shifting of the withdrawable circuit breaker (optional) 19 Mechanical unlock of the crank for withdrawing/inserting (for withdrawable design only) 20 Overcurrent release 21 Rated current module 22 „Mechanical OFF“ push-button or mushroom „Emergency OFF“ push-button (optional) 23 Mechanical indicator „ready-to-close“ 24 Mechanical indicator of circuit breaker state 25 Mechanical indicator of switching off by overcurrent release (reset push-button) 26 Locking device against unauthorized closing (optional) 27 Control panel 28 Sliding contact module Withdrawable device (1) (1) (2) (2) (18) (18) (3) (17) (17) (4) (3) (4) (5) (5) (16) (16) (6) (6) (7) (7) (15) (15) (14) (14) (8) (8) (13) (13) 1 Arc chute cover (optional) 2 Exhaust holes 3 Holes for crane hooks 4 Insulation cover (optional) 5 Insulation cover locking 6 Type label of withdrawable device 7 Disconnecting (break) contacts of main leads 8 Hole for protective earthing - diameter 14 mm 9 Locking device for withdrawing rails 10 Blocking of withdrawal at open switchboard door (optional) 11 Blocking device against switchboard door opening (optional) 12 Withdrawing rail 13 Coding of rated current of circuit breaker 14 Protection by earthing - contact module for withdrawable device (optional) 15 Coding of withdrawable device (optional) 16 Lever for insulation cover opening (optional) 17 For position signalling in the withdrawable device (optional) 18 Sliding contact module (12) (12) (9) (9) (11) (11) (10) (10) NSE00966 55 Arion Technical information 3P 4P CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Dimensions - size I - fixed design 5) 9) 60,5 60.5 1) 2) NSE00614a 4) 8) 33,5 33.5 90 35 Rear horizontal connection 90 90 60 55 Øø13.5 13,5 a 327.5 327,5 541.5 541,5 461.5 461,5 ØM8 a 45 150 210 230 NSE00617a 76 5,5 15 10 270 300 390 7) 3) 7) 275 3) 150 NSE00611 123.5 123,5 437.5 434 275 440.5 439,5 11) 6) 139 320 410 58 106 127 47 NSE00612b 55 55 NSE00613b 421 451 11) 82 ø13.5 Ø 13,5 55 55 90 55 90 55 3) NSE00616b 421 541 6 80 15 10 c 82 40 14 270 300 390 11) 10) 34 NSE00611 123.5 123,5 437.5 434 275 440.5 439,5 NSE00615b 80 40 47 4) 60 90 35 c 26 11 NSE00611 55 3) Front connection two series of holes 5) 55 10) 15 10 270 300 390 Æ 13,5 ø13.5 6 123.5 123,5 437.5 434 275 4) 440.5 439,5 5) 35 Front connection one series of holes 60 90 90 90 Rear vertical connection 4) 60 15 10 4-pole design 1) Installation space for replacement of arc chutes. 2) Deionization space, space for connection of auxiliary circuits. 4) Connectors of auxiliary circuits with screw terminals (SIGUT). 5) Connectors of auxiliary circuits with spring terminals. 6) Dimension to internal surface of closed switchboard door. 7) Fastening points for circuit breaker installation. 8) Locking device against unauthorized closing, on the front control panel. 9) Locking device against mechanical ON/OFF. 10) Holes for fastening screws, diameter 10 mm. 11) Contact area. 56 30 3) 127.5 127,5 267.5 267,5 275 440.5 439,5 123.5 123,5 437.5 434 NSE00611 270 300 390 b NSE00619 35 11) NSE00618b 5) ø13.5 Æ 13,5 113.5 113,5 128.5 128,5 10) 60 Rated current 90 90 90 a b c up to 1000 A Dimension 10 10 10 1250 ÷ 2000 A 15 20 15 Arion Technical information 3P 4P CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Dimensions - size I - withdrawable design 4) 8) 9) 55 NSE00630 55 327,5 327.5 30 55 11) NSE00627a 10) 220 367,5 367.5 382,5 382.5 3) 76 a 460 3) 275 150 275 468.5 465,5 13 210 300 55 ø13.5 Ø 13,5 123.5 123,5 10) 55 38 7) NSE00624a a 320 270 5) NSE00621 Rear horizontal connection 45 58 88,5 121,5 121.5 140.5 140,5 6) 10) 15 90 55 90 139 270 320 410 10) 90 68 25 62.5 62,5 NSE00622a 373 6 11) 3) c 169.5 169,5 90 15 90 35 30 55 55 NSE00623a 26 13 210 300 55 ø13.5 ø13,5 10) 11 10) 55 35 55 123.5 123,5 403 4) 275 468.5 465,5 320 270 5) NSE00621 Front connection one series of holes 90 62.5 62,5 4-pole design 4) Connectors of auxiliary circuits with screw terminals (SIGUT). 5) Connectors of auxiliary circuits with spring terminals. 6) Dimension to internal surface of closed switchboard door. 7) Arion in operating position. 8) Arion in test position. 9) Arion in disconnected position. 10) Holes for fastening screws, diameter 10 mm. 11) Contact area. 55 55 80 NSE00626a 373 493 11) 80 40 30 55 55 10) c 169,5 169.5 14 13 210 300 55 40 NSE00625a 123.5 123,5 10) Ø 13,5 ø13.5 6 34 4) 275 468.5 465,5 320 270 5) NSE00621 Front connection two series of holes 15 Rated current 90 90 90 a b c up to 1000 A Dimension 10 10 10 1250 ÷ 2000 A 15 20 15 57 Arion Technical information 3P 4P CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Dimensions - size I - withdrawable design 4) 11) Øø13.5 13,5 b NSE00629 38 10) 13 210 300 30 267.5 267,5 127,5 127.5 275 123,5 123.5 468.5 465,5 60 320 270 5) NSE00621 Rear vertical connection NSE00628a 30 55 3) 10) 150 165 15 90 90 90 55 NSE00631 13 210 300 30 55 4-pole design 4) Connectors of auxiliary circuits with screw terminals (SIGUT). 5) Connectors of auxiliary circuits with spring terminals. 6) Dimension to internal surface of closed switchboard door. 7) Arion in operating position. 8) Arion in test position. 9) Arion in disconnected position. 10) Holes for fastening screws, diameter 10 mm. 11) Contact area. 58 55 59 33 Ø M 12 26 121 59 282.5 282,5 10) 3) 142.5 142,5 123,5 123.5 10) 55 55 14 275 4) 468.5 465,5 320 270 5) NSE00621 Rear flanged connection NSE00632 15 90 Rated current 90 90 a b c up to 1000 A Dimension 10 10 10 1250 ÷ 2000 A 15 20 15 Arion Technical information 3P 4P CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Dimensions - size II - fixed design Rear horizontal connection 1) 130 NSE00642 130 130 130 90 90 90 NSE0_00635c NSE00634c 90 40 421 26 c 82 128 11) 35 10) 10 85 139 460 590 130 3) 11 7) 35 90 6 451 440.5 435,5 275 NSE00633 6) 40 123.5 123,5 437.5 434 106 127 47 4) 570 11) 76 5,5 5.5 45 150 210 230 Front connection one series of holes 270 440 30 Ø9 10) 570 5) 90 3) Ø 13,5 ø13.5 7) 327.5 327,5 541,5 541.5 461.5 461,5 3) 10 85 270 440 130 3) 275 150 a 275 NSE00633 123.5 123,5 437.5 434 440.5 435,5 a 30 90 35 2) NSE0_00639f 5) NSE00636a 4) 90 130 130 130 ø13.5 Ø13,5 Front connection two series of holes 4) 4-pole design 1) Installation space for replacement of arc chutes. 2) Deionization space, space for connection of auxiliary circuits. 4) Connectors of auxiliary circuits with screw terminals (SIGUT). 5) Connectors of auxiliary circuits with spring terminals. 6) Dimension to internal surface of closed switchboard door. 7) Fastening points for circuit breaker installation. 10) Holes for fastening screws, diameter 10 mm. 11) Contact area. 90 40 90 80 40 90 421 NSE0_00638c NSE00637c 3) 11) 14 541 34 10) 10 85 570 90 40 80 270 440 6 c 82 40 NSE00633 123.5 123,5 437.5 434 275 47 440.5 435,5 5) 90 130 130 130 Rated current ø13.5 Ø13,5 a b c up to 2000 A Dimension 10 15 10 2500 A 15 15 20 3200 A 30 30 20 59 Arion Technical information 3P 4P CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Dimensions - size II - fixed design 30 b NSE00641 134.5 134,5 98 3) 290 275 440.5 435,5 123.5 123,5 437.5 434 NSE00633 10 85 270 440 30 4) 5) Øø13.5 13,5 Rear vertical connection 10) 35 NSE00640b 11) 570 113.5 113,5 128,5 128.5 90 130 130 130 Rear vertical connection - 4000 A 4) 1) 10 85 Ø 13.5 4011) 142 162 10 20 200 130 200 570 4-pole design 1) Installation space for replacement of arc chutes. 2) Deionization space, space for connection of auxiliary circuits. 4) Connectors of auxiliary circuits with screw terminals (SIGUT). 5) Connectors of auxiliary circuits with spring terminals. 6) Dimension to internal surface of closed switchboard door. 7) Fastening points for circuit breaker installation. 10) Holes for fastening screws, diameter 10 mm. 11) Contact area. 60 2) 85 Nm NSE0_01868a 541.5 516 345.5 100 30 275 123.5 123,5 437.5 434 NSE00633 270 440 440.5 435,5 30 5) Rated current a b c up to 2000 A Dimension 10 15 10 2500 A 15 15 20 3200 A 30 30 20 Arion Technical information 3P 4P CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Dimensions - size II - withdrawable design Rear horizontal connection 76 45 58 88,5 88.5 121,5 121.5 140,5 140.5 10) 55 45 130 130 Front connection one series of holes 5) NSE00643a 4) 480 55 10) 4 0 9 0 9 0 3 5 NSE00644b 3 ) 3 7 3 1 1 ) 2 6 403 9 0 5 3 0 138 95 6 9 40 4 0 0 9 0 139 270 460 590 10) 130 ø13.5 1 3 ,5 10) 11 270 350 4 0 6 123.5 123,5 465.5 461 275 468.5 465,5 62,5 62.5 10) 38 11) NSE00649a 150 Ø 13,5 ø13.5 3) a 460 10) 30 30 2 8 7 55 40,5 40.5 90 90 N S E 0 _ 0 0 6 4 5 c 40 327.5 327,5 a 480 270 350 275 275 468.5 465,5 123.5 123,5 465.5 461 10) 10) 220 367.5 367,5 382,5 382.5 90 90 7) 8) 9) NSE00646a c 169.5 169,5 445.1 5 ,1 1 3 0 5 5 1 3 0 1 3 0 3 5 4) NSE00652a 5) NSE00643a 40 ø13.5 Ø13,5 4) 480 270 350 40 55 4-pole design 4) Connectors of auxiliary circuits with screw terminals (SIGUT). 5) Connectors of auxiliary circuits with spring terminals. 7) Arion in operating position. 8) Arion in test position. 9) Arion in disconnected position. 10) Holes for fastening screws, diameter 10 mm. 11) Contact area. 90 80 NSE00647b 11) 287 3) 373 10) 14 c 169.5 169,5 55 45 130 Rated current 130 69 493 10) 90 40 530 400 90 90 40 80 10) 6 34 123.5 123,5 465.5 461 275 468.5 465,5 62,5 62.5 40 5) NSE00643a NSE0_00648c Front connection two series of holes 130 a b c up to 2000 A Dimension 10 15 10 2500 A 15 15 20 3200 A 30 30 20 61 Arion Technical information 3P 4P CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Dimensions - size II - withdrawable design Rear vertical connection 4) 11) 38 b 10) 480 270 350 40 55 NSE00651 10) 100 290 3) 135 123.5 123,5 465.5 461 468.5 465,5 275 30 30 NSE00650a 5) NSE00643a 10) 157 172 55 45 130 130 130 Rear flanged connection 480 270 350 40 55 10) 4-pole design 4) Connectors of auxiliary circuits with screw terminals (SIGUT). 5) Connectors of auxiliary circuits with spring terminals. 7) Arion in operating position. 8) Arion in test position. 9) Arion in disconnected position. 10) Holes for fastening screws, diameter 10 mm. 11) Contact area. 90 40 NSE00654 33 26 275 10) 121 3) 59 282,5 282.5 59 468.5 465,5 123.5 123,5 465.5 461 10) 62 Ø M 12 142.5 142,5 4) NSE00653 5) NSE00643a 45 130 130 Rated current 130 a b c up to 2000 A Dimension 10 15 10 2500 A 15 15 20 3200 A 30 30 20 Arion Technical information 3P 4P CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Dimensions - size III - fixed design Rear horizontal connection 1) NSE00658a 5) 4) 2) 205 7) 210 160 210 15 210 ø13.5 Ø 13,5 130 914 248 5.5 5,5 150 210 230 45 106 127 130 6) 210 210 210 130 11) 7) Ø M 10 139 704 10) NSE00661a 30 3) 35 890 3) 327,5 327.5 35 440.5 439 437.5 434 270 680 NSE00664a 76 541,5 541.5 461.5 461,5 275 150 30 30 12 275 123,5 123.5 NSE00655 47 160 NSE0_00657c 421 20 82 11) 130 210 210 210 35 205 890 160 3) 10) 11 270 680 12 160 50 50 26 451 275 6 123,5 123.5 440.5 439 437.5 434 160 50 50 ø13.5 13,5 NSE00656c 5) 4) NSE00655 35 Front connection one series of holes 4-pole design 1) Installation space for replacement of arc chutes. 2) Deionization space, space for connection of auxiliary circuits. 4) Connectors of auxiliary circuits with screw terminals (SIGUT). 5) Connectors of auxiliary circuits with spring terminals. 6) Dimension to internal surface of closed switchboard door. 7) Fastening points for circuit breaker installation. 10) Holes for fastening screws, diameter 10 mm. 11) Contact area. 63 Arion Technical information 3P 4P CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Dimensions - size III - fixed design Front connection two series of holes 40 15 30 205 12 890 4-pole design 1) Installation space for replacement of arc chutes. 2) Deionization space, space for connection of auxiliary circuits. 4) Connectors of auxiliary circuits with screw terminals (SIGUT). 5) Connectors of auxiliary circuits with spring terminals. 6) Dimension to internal surface of closed switchboard door. 7) Fastening points for circuit breaker installation. 10) Holes for fastening screws, diameter 10 mm. 11) Contact area. 64 330.5 330,5 Ø 13,5 ø13.5 80 80 130 210 210 210 107 20 10 40 NSE00663 3) 94,5 94.5 120 275 440.5 439 123.5 123,5 437.5 434 270 680 11) 160 NSE0_00660c 421 Rear vertical connection 5) 4) 160 3) 40 20 82 NSE00655 160 50 50 14 34 12 890 160 50 50 10) 10) 40 142 162 NSE00662a 205 NSE00659c 541 275 440.5 439 123.5 123,5 437.5 434 270 680 6 ø13.5 Ø 13,5 47 5) 4) NSE00655 85 210 210 210 11) Arion Technical information 3P 4P CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Dimensions - size III - withdrawable design Rear horizontal connection 7) 10) 800 30 30 160 57 NSE00668a 10) 10) 220 40,5 40.5 367,5 367.5 382,5 382.5 160 160 NSE00674 327,5 327.5 460 3) 160 45 58 88.5 88,5 121.5 121,5 140,5 140.5 6) 57 85 210 210 210 ø13.5 Ø 13,5 38 30 270 590 160 275 150 30 468.5 466,5 123,5 123.5 465.5 461 10) 8) 9) 30 NSE00665a 76 4) 275 5) NSE00671a 11) 260 217 800 69 800 57 20 169,5 169.5 NSE0_00670c 160 80 160 11) 14 10) 10) 160 50 50 287 160 630 160 50 50 69 270 590 34 10) 210 210 590 373 6 123,5 123.5 493 NSE00669b NSE00665a 465.5 461 10) 40 Ø13,5 ø13.5 62,5 62.5 4) 210 840 275 468.5 466,5 5) 85 57 Front connection two series of holes 287 373 20 169,5 169.5 35 57 160 10) 10) 26 160 160 11) 40 800 270 590 11 10) 160 50 50 35 NSE00666b 6 123,5 123.5 403 NSE00665a 465.5 461 10) 13,5 ø13.5 62.5 62,5 4) 275 468.5 466,5 5) 630 160 50 50 NSE0_00667c 840 Front connection one series of holes 80 914 139 270 704 85 210 590 210 210 800 4-pole design 4) Connectors of auxiliary circuits with screw terminals (SIGUT). 5) Connectors of auxiliary circuits with spring terminals. 6) Dimension to internal surface of closed switchboard door. 7) ARION in operating position. 8) ARION in test position. 9) ARION in disconnected position. 10) Holes for fastening screws, diameter 10 mm. 11) Contact area. Rated current a b up to 4000 A Dimension 40 210 5000 A 40 210 6300 A 5 245 65 Arion Technical information 3P 4P CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Dimensions - size III - withdrawable design Rear vertical connection NSE00665a 38 11) 20 10 NSE00672a 4) 704 NSE00673a 10) 10) 800 270 590 160 57 330,5 330.5 94.5 94,5 124.5 124,5 123.5 123,5 465.5 461 275 468.5 466,5 30 5) 10) Øø13.5 13,5 10) a 57 24 177 197 b c 590 800 210 914 800 270 590 160 57 10) 10) 4-pole design 4) Connectors of auxiliary circuits with screw terminals (SIGUT). 5) Connectors of auxiliary circuits with spring terminals. 6) Dimension to internal surface of closed switchboard door. 7) Arion in operating position. 8) Arion in test position. 9) Arion in disconnected position. 10) Holes for fastening screws, diameter 10 mm. 11) Contact area. 59 5 57 85 121 66 160 160 Rated current 30 210 210 590 210 NSE00676 10) 282.5 282,5 142.5 142,5 468.5 466,5 123.5 123,5 465.5 461 10) 704 160 160 59 NSE00665a Ø M 12 33 26 4) 275 5) NSE00675 Rear flanged connection 800 914 a b up to 4000 A Dimension 40 210 5000 A 40 210 6300 A 5 245 Technical information CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Arion 3P 4P Dimensions - accessories Measuring voltage transformers - 3WL9111-0BB68-0AA0 125 277 NSE0_01103a Installation on standard Montá na standardní DIN rail lištu35 35mm mm DIN 99 External measuring current transformer for N conductor with Cu busbars - size I - 3WL9111-0AA31-0AA0 97 83 55 41 170 130 68 51 44 ø13.5 Ø 13,5 15 NSE00606 External measuring current transformer for N conductor with Cu busbars - size II - 3WL9111-0AA32-0AA0 3x10 30 30 50.5 50,5 170 130 68 51 44 ø13.5 Ø 13,5 NSE00607 90 131 External measuring current transformer for N conductor with Cu busbars - size III - 3WL9111-0AA33-0AA0 3x10 30 30 30 52 170 130 68 51 44 Øø13.5 13,5 NSE00608 160 123 External measuring current transformer for N conductor without Cu busbars - size I - 3WL9111-0AA21-0AA0 60 16 8 R 22 18 NSE0_01375 40 22 81 96,8 96.8 8,9 8.9 R13.1 R 13,1 51 36 70 83 Voltage source - 6EP1333-2AA01 Voltage source - 6EP1332-2BA10 125.3 125,3 120.3 120,3 125.5 125,5 120,5 120.5 32.4 32,4 44,2 125 125 45 50 67 Arion Technical informatio 3P 4P CIRCUIT BREAKERS, SWITCH-DISCONNECTORS Dimensions - accessories External measuring current transformer for N conductor without Cu busbars - size II - 3WL9111-0AA22-0AA0 65,5 65.5 NSE0_01376 54 115 131 R 27 51 88 95 113 3 External measuring current transformer for N conductor without Cu busbars - size III - 3WL9111-0AA23-0AA0 161 NSE0_01377 107 123 3 31 45 R 15 51 160 184 Cutout in the switchboard door for control panel at use of the sealing frame 3 1 4 1 2 0 ø5.5 Ø 5 ,5 4 0 3 ) 2 ) 1) Mounting plane 2) Control panel axis 3) 8 mounting holes for the door sealing frame 4) 3 mounting holes for the switchboard door blocking 1 8 0 1 4 0 4 0 1 2 0 Ø ø5.5 5 ,5 11.5 1 1 ,5 6 5 1 7 5 3 5 0 Øø5.5 5 ,5 1 8 5 R 5 R 5 1 4 0 N S E 0 _ 0 0 6 1 0 c 3 0 0 1 ) 1 2 2 1 4 ) 4 0 NSE0_01030a Cutout in the switchboard door for control panel at use of the transparent cover 4 x R5 ° 80 295-300 341 Montání rovina jistièe plane Circuit breaker mounting 68 330 17 444 4 x 5,5 Montání rovina Circuit breaker jistièe mounting plane 149 Arion Technical information 3P 4P WITHDRAWABLE DEVICE Description Withdrawable circuit breaker/switch-disconnector is intended for harsh industrial environment, which requires quick replacement of the circuit breaker, frequent inspections, and visible, galvanic disconnection of the circuit. Circuit breaker positions in the withdrawable device Figure (1) Position for maintenance (2) Signalling of position NSE01033 Auxiliary circuits Switchboard door Insulation cover CONNECT TEST (4) Main current paths disconnected disconnected open closed disconnected disconnected closed closed disconnected connected closed closed connected connected closed open DISCON NSE01037 CONNECT Disconnected position (3) TEST DISCON NSE01034 NSE01038 CONNECT Test position (Inspection position) TEST DISCON NSE01035 NSE01039 CONNECT Working position TEST DISCON NSE01008 NSE01009 NSE01040 Arc chute covers 3WL9111-0AS..-0AA0 or complement code „R10“ Arc chute cover is used for the protection of the switchgear equipment, which is installed directly above the circuit breaker arch chutes. The cover is optional accessory for the withdrawable device. Coding of withdrawable device 3WL111-0AR12-0AA0 Withdrawable circuit breaker and withdrawable device can be optionally equipped with an additional coding device, which is set according to the circuit breaker equipment. The coding device enables custom coding of both the circuit breaker and withdrawable device according to installed equipment. If the frame and the circuit breaker have different codes, it is not possible to slide the circuit breaker into the withdrawable device. The coding device has 36 different codes. Insulation cover 3WL9111-0AP..-0AA0 or complement code „R21“ Insulation cover consists of insulating strips, which cover lamellar contacts of main current paths in the withdrawable device. The insulation cover prevents from contact with the live parts of the device. The insulation strips can be lifted manually from the protective position by a lever. The insulation strips can be fixed in various positions by padlocks, which prevent from unauthorized handling. Coding device according to rated current Withdrawable circuit breaker and withdrawable device are normally equipped with coding device according to rated current. This coding device enables insertion into the withdrawable device only of the circuit breaker of relevant size, with compatible size of contact blades of the main current paths. (1) (4) NSE01031 NSE01036 (2) (3) NSE01032 (5) (1) Withdrawable device, left internal side; right internal side by analogy (2) Coding pin on the guide rail on the withdrawable device (3) Guide rail (4) Withdrawable circuit breaker, right side; left side by analogy (5) Coding pin in the withdrawable device 69 Arion Technical information 3P 4P WITHDRAWABLE DEVICE For position signalling in the withdrawable device Withdrawable device can be additionally equipped with position signal switches. They enable determination of the circuit breaker position in the frame. For position signalling, they are delivered installed on the bearing plate, with connecting cables long 1.5 m. Two types are delivered with various number of contacts. 3WL9111-0AH11-0AA0 or complement code 3WL9111-0AH12-0AA0 or complement code 1 Number of contacts according to type Design Position Disconnected Test Operating 3WL9111-0AH11-0AA0 1 make-and-break 1 make-and-break 1 make-and-break or complement code „R15“ 3WL9111-0AH12-0AA0 1 make-and-break 2 make-and-break 3 make-and-break or complement code „R16“ States of position signal switches Signal switch Contacts Disconnected position Circuit breaker position Test position S30 S31 / S32 S33 / S34 / S35 - contact open - contact closed Parameters of the position signal switches Rated operating voltage Ue Rated insulation voltage Ui Rated frequency fn Rated operating current Ie Protection 70 AC-12 AC-15 DC-12 DC-13 Fuse Circuit breaker 250 V a.c./d.c. 440 V a.c./250 V d.c. 50/60 Hz 10 A/24 ÷ 440 V 4 A/230 V, 3 A/440 V 10 A/24 V, 2.5 A/48 V, 0.2 A/240 V 3 A/24 V, 0.1 A/240 V Max. PVA10 8A gG Max. LPN-8C-1 Working position Technical information Arion 3P 4P OVERCURRENT RELEASES Description Basic description The overcurrent releases are used for protection of transformers, lines, circuits, motors and other devices such as, for example, frequency converters etc. For each application it is possible to select an optimal overcurrent release according to requirements from the viewpoint of protective and other functions, e.g. data communication. For more information about data communication and measuring function see page 82. Overcurrent releases are electronic and controlled by a microprocessor. They work independently of the voltage in the circuit. The overcurrent releases do not need an external power supply for their protective function. The power supply is necessary, if the circuit breaker is equipped with measuring function Plus or data communication. All overcurrent releases enable the control of rated current in the range 0.4 ÷ 1 In. Overview of parameters of overcurrent releases is on page 72. On other pages there is a description of individual overcurrent releases including tripping characteristics. Overcurrent release models ETU45B and higher enable the setting of I4t = constant The tripping (time-current) characteristic thus gets near to the fuse time-current characteristic. This ensures higher degree of selectivity between the circuit breaker and the fuses. Eventual failure of the microprocessor is signaled on all releases by red LED. Display Overcurrent release ETU45B can be equipped with a 4-line LCD display. Overcurrent release ETU76B has an integrated graphic display. The displays can show, for instance, the values of measured quantities in a circuit. The parameters of the overcurrent release ETU76B are set by means of the display and push-buttons. Overcurrent release parameter setting For overcurrent releases ETU15B to ETU45B, the basic parameters of protective functions are set by means of rotary switches. Some other parameters of the overcurrent release ETU45B are set only via data communication. These functions are only accessible if the circuit breaker is equipped with measuring function Plus see page 82. Overcurrent release ETU76B can be set directly by means of push-buttons and display via menu or also via data communication. Rated current module The overcurrent releases, except ETU15B, contain a „Rated current module”. Normally, each circuit breaker is equipped with a rated current module of the rating corresponding to maximum rated current of the circuit breaker. If a lower rated current of the circuit breaker is required, it is possible to deliver the circuit breaker with an overcurrent release containing the rated current module of required value, see page 27. The rated current module can also be replaced additionally to decrease the rated current of the circuit breaker, see page 35. The rated current module can be used for permanent or temporary reduction of the rated current. For example, in commissioning of a new plant a lower rated current is needed initially. The rated current control 0.4 ÷ 1 In depends on the rated current of the module and not on the maximum current of the circuit breaker. Example: Circuit breaker with max. rated current 2500 A with standard rated current module - Ir setting 1000 ÷ 2500 A Circuit breaker with max. rated current 2500 A and rated current module with In = 1000 A - Ir setting 400 ÷ 1000 A Switchable set of parameters Overcurrent releases ETU76B allow for setting of two parameter sets (two various tripping characteristics) in the memory for protection of two different devices. By simple switching over between these sets of parameters (for ETU76B via data communication and for ETU76B also via the menu of the release) the circuit breaker is ready to protect other device in 200 ms. N conductor protection or switching N conductor protection is ensured by overcurrent releases ETU27B or higher. For current measuring N conductor, the 3-pole circuit breaker must be completed by an external current transformer for N conductor, see page 36. 4-pole circuit breakers must be equipped with an internal current transformer for N conductor, see page 28. For 4-pole circuit breakers without the internal current transformer for N conductor N conductor is only switched. For possible setting of N conductor protection see the table on page 72. Earth fault protection See page 81. Testing of overcurrent releases and disconnection signalling The functionality of an overcurrent release can be tested on the overcurrent release itself. Basic test of protective functions of the overcurrent release is activated by pressing the „TEST“ key on the overcurrent release. Overcurrent releases can also be tested by special testers see page 35. For more information, please contact OEZ’s technical support. See the contact at the end of the catalogue. Detailed information about the overcurrent release testing will be delivered on request or see „Detailed Instructions for Use“ at www.oez.com. Overcurrent releases can signal a cause of disconnection by means of LEDs. LEDs are installed directly on the overcurrent release. The signalling can be activated by „QUERY“ key. The LED corresponding to the protective function which caused the circuit breaker disconnection, lights when the key is pressed. The overcurrent release remembers the cause of the last disconnection until its memory is cleared by „CLEAR“ key, however maximum for 24 hours. immediately after the circuit breaker closing i.e. when the overcurrent release has not measured current, the relevant switching off time is extended by up to 15 ms depending on the value of the current. Time and current tolerance are specified for the characteristics. The characteristics are valid at ambient temperature –5 up to +55 °C. The release can be operated at –20 up to +70 °C. For these temperature there is an extended tolerance range. The circuit breaker with overcurrent release ETU76B with graphic display can be operated at temperature up to +55 °C. See program Sichr for visual demonstration of the tripping characteristics. Reset after circuit breaker switching off by overcurrent release After circuit breaker switching off by an overcurrent release, the overcurrent release must be reset. It is not possible to switch on the circuit breaker without the overcurrent release reset. After the circuit breaker switching off by overcurrent release, the red indicating push-button on the overcurrent release, which is used for mechanical local signalling of „switched off by overcurrent release“ and also for local manual reset of the overcurrent release, slips out. Automatic reset The circuit breaker can be equipped with automatic reset function (complement code „K01“). If the circuit breaker is equipped with this function, after its switching off by overcurrent release, the overcurrent release is reset automatically immediately and the circuit breaker is readyto-close. The red indicating push-button remains extended after the automatic reset. It signals the circuit breaker switching off by overcurrent release until its manual or remote reset. Remote reset The circuit breaker equipped with the automatic reset can be also equipped with remote reset. The remote reset function makes it possible to carry out remote electrical reset of the indicating push-button signalling the switching off by overcurrent release. It is also possible to perform manual reset of the indicating push-button. Overcurrent release sealing It is possible to put a sealable transparent cover on the overcurrent release. The elements used for parameter setting are covered, and thus unauthorized access to parameter setting is eliminated. The openings in the cover enable access to query and test push-buttons. There is also a lockable cap, which prevents from manual reset of the „switched off by overcurrent release“ indicator. Tripping characteristics Each type of the Arion overcurrent release has its own characteristic. Complete characteristic of a release is created by combining individual parts of characteristics. Characteristics illustrate the response of the overcurrent release to current under the state, when current already passes through the circuit breaker. If the overcurrent release is activated 71 Arion Technical information 3P 4P OVERCURRENT RELEASES - OVERVIEW OF PARAMETERS Specifications Basic functions Type of overcurrent release Overload protection The function can be switched on and off Setting range IR = In x ... L IR tR N S Isd tsd Ii I G Switchable parameter sets LCD display Switchable overload protection (functional dependence I2t- or I4t) Setting range of delay time tR for I2t at 6x In Setting range of delay time tR for I4t at 6x In Thermal memory Phase failure sensitivity Protection of N conductor The function can be switched on and off Setting range for N conductor N IN = In x ... Short-time delayed short-circuit protection The function can be switched on and off Setting range Isd = In x ... Setting range of delay time tsd Switchable short-time delayed short-circuit protection (functional dependence I2t) Setting range of delay time tsd at I2t Function ZSS-s (time shortened selectivity control) Instantaneous short-circuit protection The function can be switched on and off Setting range Ii Earth fault protection Tripping and alarm signalling function The tripping function can be switched on and off The alarm signalling function can be switched on and off Measuring of short-circuit current by vectorial addition of currents by means of internal measuring current transformers on N conductor Measuring of short-circuit current by external measuring current transformer on protective conductor Setting range of limit for tripping Ig Setting range of limit for alarm signalling Ig Setting range of delay time tg Switchable function of short-circuit protection (functional dependence I2t) Setting range of delay time tg at I2t Function ZSS-g (time shortened selectivity control) Alphanumeric, 4-line Graphic Data communication Integrated CubicleBUS Possible data communication via PROFIBUS protocol Possible data communication via MODBUS protocol Measuring function Measuring function Plus LED signalling active overcurrent release alarm signalling faulty ETU switching off by function L switching off by function S switching off by function I switching off by function N switching off by function G G - alarm signalling switching off by extended protective function communication Reporting by signal contacts via external CubicleBUS modules (optical elements or relays) alarm: overload load reduction, load connection alarm: high temperature phase asymmetry instantaneous disconnection at short-circuit short-time delayed disconnection at short-circuit tripping from overload tripping from overload of N conductor earth fault tripping alarm: earth fault auxiliary relay faulty ETU − the function is unavailable; + the function is available; z the function is optional 1) M = motor protection. 72 ETU15B + − 0.5-0.6-0.7-0.8-0.9-1 − 10 s fixed − − − − − − − − − − − − − + − 2-3-4-5-6-7-8x In − − − − ETU25B + − 0.4-0.45-0.5-0.55 0.6-0.65-0.7-0.8-0.9-1 − 10 s fixed − − at tsd = 20 ms (M) 1) − − − + − 1.25-1.5-2-2.5-3-4-6-8-10-12 0-M-100-200-300-400 − − − + − fixed at Ii ≥ 20x In, max. 50 kA − − − − ETU27B + − 0.4-0.45-0.5-0.55 0.6-0.65-0.7-0.8-0.9-1 − 10 s fixed − − at tsd = 20 ms (M) 1) + + (by sliding switch) 1 + − 1.25-1.5-2-2.5-3-4-6-8-10-12 0-M-100-200-300-400 − − − + − fixed at Ii ≥ 20x In, max. 50 kA + fixed integrated − + (by rotary switch) − − − + − − − − − − − − − − − − − − − − + + + − − − − − − − − − − − − − − − − − − − − − + + + + + + − − − − − A-B-C-D-E − 100-200-300-400-500 ms − − − − − − − − − − + + + + + + + + − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − Arion Technical information 3P 4P OVERCURRENT RELEASES - OVERVIEW OF PARAMETERS Specifications Basic functions Overload protection The function can be switched on and off Setting range IR = In x ... Switchable overload protection (functional dependence I2t or I4t) Setting range of delay time tR for I2t Setting range of delay time tR for I4t Thermal memory Phase failure sensitivity Protection of N conductor The function can be switched on and off Setting range for N conductor N IN Short-time delayed short-circuit protection The function can be switched on and off Setting range Isd Setting range of delay time tsd Switchable short-time delayed short-circuit protection (functional dependence I2t) Setting range of delay time tsd at I2t Function ZSS-s (time shortened selectivity control) Instantaneous short-circuit protection The function can be switched on and off Setting range Ii Earth fault protection Tripping and alarm signalling function The tripping function can be switched on and off The alarm signalling function can be switched on and off Measuring of short-circuit current by vectorial addition of currents by means of internal measuring current transformers on N conductor Measuring of short-circuit current by external measuring current transformer on protective conductor Setting range of limit for tripping Ig Setting range of limit for alarm signalling Ig Setting range of delay time tg Switchable function of short-circuit protection (functional dependence I2t) Setting range of delay time tg at I2t Function ZSS-g (time shortened selectivity control) Switchable parameter sets LCD display Alphanumeric, 4-line Graphic Data communication Integrated CubicleBUS Possible data communication via PROFIBUS-DP Possible data communication via MODBUS Measuring function Measuring function Plus LED signalling active overcurrent release alarm signalling faulty ETU switching off by function L switching off by function S switching off by function I switching off by function N switching off by function G G - alarm signalling switching off by extended protective function data communication Reporting by signal contacts via external CubicleBUS modules (optical elements or relays) alarm: overload load reduction, load connection alarm: high temperature phase asymmetry instantaneous disconnection at short-circuit short-time delayed disconnection at short-circuit tripping from overload tripping from overload of N conductor earth fault tripping alarm: earth fault auxiliary relay faulty ETU 2) Value setting step: Range 0÷1 1 ÷ 100 Step 0,1 1 ETU45B + − 0.4-0.45-0.5-0.55 0.6-0.65-0.7-0.8-0.9-1 + (by sliding switch) 2-3-5-5.5-8-10-14-17-21-25-30 s 1-2-3-4-5 s + (ON/OFF by sliding switch) at tsd = 20 ms (M) 1) + + by sliding switch 0.5 ÷ 1 + + (by rotary switch) (1.25-1.5-2-2.5-3-4-6-8-10-12)x In M-100-200-300-400 ms + (by rotary switch) 100-200-300-400 ms by means of CubicleBUS + + (by rotary switch) (1.5-2.2-3-4-6-8-10-12)x In. max. 0.8x Ics + 2 ÷ 30 s 2) 1-2-3-4-5 s + (by means of menu/data communication) + (ON/OFF by means of menu/data communication) + + (by means of menu/data communication) 0.5 ÷ 2 2) + + (by means of menu/data communication) 1.25x In ÷ 0.8x Icw 2) M- 80 ÷ 4000 ms 2) + (by means of menu/data communication) 100 ÷ 400 ms 2) by means of CubicleBUS + + (by means of menu/data communication) 1.5x In ÷ 0.8x Ics 2) z z + + (by rotary switch) − + + (by means of menu/data communication) + (by means of menu/data communication) + + + + A-B-C-D-E A-B-C-D-E 100-200-300-400-500 ms + 100-200-300-400-500 ms by means of CubicleBUS − + − + A-B-C-D-E A-B-C-D-E 100 ÷ 500 ms 2) + 100 ÷ 500 ms 2) by means of CubicleBUS + − + + z z z z + + + + + + + + + (only with earth fault protection module) + (only with earth fault protection module) + + + + + + + + + + + (only with earth fault protection module) + (only with earth fault protection module) + + + + + + + + + + + (only with earth fault protection module) + (only with earth fault protection module) + + + + + + + + + + + (only with earth fault protection module) + (only with earth fault protection module) + + 100 ÷ 500 5 500 ÷ 1000 10 ETU76B + + 0.4 ÷ 1 2) 1000 ÷ 1600 50 1600 ÷ 10000 100 10000 ÷ max 1000 73 Arion Technical information 3P 4P OVERCURRENT RELEASES - ETU15B Description Use Simple protection of installations in buildings and protection of equipment without time selectivity up to 6300 A. Mechanical reset of reclosing blocking Option: safety lock, prevents from pressing of reset push-button after switching off by overcurrent Properties adjustable overload protection with characteristic I2t with fixed delay tR = 10 s at 6x IR instantaneous short-circuit protection in the range (2 ÷ 8)x In protective function setting by rotary switch Signalling: overcurrent release activated Alarm signalling: overload For other technical data see the table on page 72. Function Signalling: faulty overcurrent release Rotary switch: setting of limit of switching off by overcurrent Rotary switch: setting of limit of instantaneous tripping at short-circuit Sealing lug Test connector Tripping characteristic R min 1000 . NSE0_01527 10000 R max . 100 10 1 i min i max 0,1 . 0,01 . 0,1 . 1 10 100 / n Tolerance at set current: L: tripping between 1.05 and 1.2x IR I: - 0 %, +20 % Tripping time tolerance: L: - 20 %, + 0 % for characteristic I2t I: < 50 ms 74 Technical information Arion 3P 4P OVERCURRENT RELEASES - ETU25B Description Use Classical protection of building installations, motors and equipment with time selectivity up to 6300 A. Mechanical reset of reclosing blocking Properties adjustable overload protection with characteristic I2t with fixed delay tR = 10 s at 6x IR short-time delayed short-circuit protection, adjustable to (1.25 ÷ 12)x In instantaneous short-circuit protection set to 20x In , max. 50 kA signalling overload LED signalling of tripping cause possible overcurrent release testing function protective function setting by rotary switch Option: safety lock, prevents from pressing of reset push-button after switching off by overcurrent Signalling: overcurrent release activated Alarm signalling: overload Rated current module For other technical data see the table on page 72. Function IR Signalling: faulty overcurrent release Rotary switch: setting of limit of switching off by overcurrent Signalling of release tripping cause Rotary switch: setting of shorttime delayed short-circuit protection Fixed instantaneous short-circuit protection Rotary switch: setting of tripping delay at short-circuit Query push-button Test push-button I sd t sd Sealing lug Reset push-button Test connector Tripping characteristic R min NSE0_01520 10000 R max . ... 1,0 . x n 0,4 1000 100 10 sd min 1 1,25 . ... 12 x n sd max 0 ... 0,4 . s 0,1 i i > 20 x n max. 50 kA 0,01 . . 0,1 1 10 100 / n Tolerance at set current: L: tripping between 1.05 and 1.2x IR S: - 0 %, +20 % I: - 0 %, +20 % Tripping time tolerance: L: - 20 %, + 0 % for characteristic I2t S: - 0 %, + 60 ms nebo –0 %, +10 % for characteristics with fixed delay I: < 50 ms 75 Arion Technical information 3P 4P OVERCURRENT RELEASES - ETU27B Description Use Classical protection of building installations, motors and equipment with time selectivity up to 6300 A. The overcurrent release has fixed integrated earth fault protection module. Option: safety lock, prevents from pressing of reset push-button after switching off by overcurrent Mechanical reset of reclosing blocking Properties adjustable overload protection with characteristic I2t with fixed delay tR = 10 s at 6x IR short-time delayed short-circuit protection, adjustable to (1.25 ÷ 12)x In instantaneous short-circuit protection set to 20x In , max. 50 kA overload signalling LED signalling of tripping cause possible overcurrent release testing function protective function setting by rotary or sliding switches possible protection of N conductor fixed integrated earth fault protection module – calculation of earth current from vector sum of individual currents Signalling: overcurrent release activated Alarm signalling: overload Rated current module Signalling: faulty overcurrent release Signalling of release tripping cause Rotary switch: setting of limit of switching off by overcurrent Rotary switch: setting of short-time delayed short-circuit protection Fixed instantaneous short-circuit protection For other technical data see the table on page 72. Rotary switch: setting of tripping delay at short-circuit Sealing lug Rotary switch: setting earth fault protection Function Rotary switch: setting of delay of protection at earth fault Query push-button Test push-button Reset push-button Test connector Tripping characteristic Function G R min R max 0,4 . ... 1,0 . x 1000 NSE0_01519 10000 n N 10000 1000 100 100 10 10 sd min 1 g min g max 100 ... 1200 A 1) sd max 1 1,25 . ... 12 x n g max 0,1 . ... 0,5 . s 0 ... 0,4 . s 0,1 . NSE0_01521 Function LSI i 0,1 . > 20 x n max. 50 kA g min i 0,01 . 0,01 . 0,1 . 1 10 100 100 1000 10000 / n 1) Size Velikost Size Velikost Tolerance at set current: L: tripping between 1.05 and 1.2x IR S: - 0 %, +20 % I: - 0 %, +20 % G: - 0 %, +20 % 76 100000 A Tripping time tolerance: L: - 20 %, + 0 % for characteristic I2t S: - 0 %, + 60 ms or –0 %, +10 % for characteristics with fixed delay I: < 50 ms G: - 0 ms, + 60 ms or –0 %, +10 % for characteristics with fixed delay I and II: 100 ... 1200 A III: 400 ... 1200 A. Technical information Arion 3P 4P OVERCURRENT RELEASES - ETU45B Description Use Budget-priced universal overcurrent release for intelligent buildings and for all industrial applications. Properties adjustable overload protection with characteristic I2t or I4t with adjustable delay time 2 ÷ 30 s for I2t at 6x IR, 1 ÷ 5 s for I4t at 6x IR short-time delayed short-circuit protection, adjustable to (1.25 ÷ 12)x In instantaneous short-circuit protection set from (1.5 ÷ 12)x In; max. 0.8x Ics, max. 50 kA overload signalling LED signalling of tripping cause possible overcurrent release testing function protective function setting by rotary or sliding switches adjustable delay class for overload protection switchable characteristics I2t and I4t in overload area and in the area of short-time delayed short-circuit protection for better current selectivity with assigned fuses or circuit breakers thermal memory, which is used for protection at the circuit breaker reclosing after switching off by overload – it can be disabled possible protection of N conductor (separately adjustable) optional earth fault protection module with separately adjustable alarm signalling and tripping functions possible connection of data communication and measuring function Plus independent time-delayed release with possibility of angle setting for better visibility Mechanical reset of reclosing blocking Scrolling up Signalling: overcurrent release activated Alarm signalling: overload COMMUNICATION EXTENSION F. Rated current module Rotary switch: setting of limit of switching off by overcurrent Rotary switch: setting of short-time delayed short-circuit protection Rotary switch: setting of limit of instantaneous short-circuit protection Earth fault measuring switch Rotary switch: setting of limit of earth fault protection Rotary switch: setting of limit of earth fault alarm Test push-button Query push-button Option: safety lock, prevents from pressing of reset push-button after switching off by overcurrent Optional alphanumeric display Scrolling down Signalling: faulty overcurrent release Thermal memory: ON/OFF Protection of N conductor: ON/OFF Setting of overload limit of N conductor Switching of overload characteristics I2t/I4t Rotary switch: setting of tripping delay at overload Rotary switch: setting of tripping delay at short-circuit Tripping cause signalling Sealing lug Optional earth fault modules Alarm signalling: earth fault Signalling: tripping by earth fault Rotary switch: setting of delay of protection at earth fault - tg/I2tg Reset push-button Test connector For other technical data see the table on page 72. Function 77 Arion Technical information 3P 4P OVERCURRENT RELEASES - ETU45B Tripping characteristic Function L 4 R 0,4 . ... 1,0 . x 1000 = const n 2 10000 1000 NSE0_01523 10000 NSE0_01522 Function S sd = const 1,25 . ... 12 x n 100 100 2 R 2 ... 30 for 2 1 ... 5 for 4 10 sd = const 10 1 1 2 0,1 . sd = const 0,1 . ... 0,4 . s sd = const 0,1 0,02 . ... 0,4 . s 0,01 . 0,01 . 0,1 . 1 10 . 0,1 100 1 10 100 / n / n Function G NSE0_01524 10000 1000 10000 NSE0_01525 Function I 1000 100 100 g 10 10 100 ... 1200 A 1) 1 1 i g 0,01 . 0,01 . . 0,1 1 10 100 100 1000 / n ... 1200 A Size III: 400 ...III1200 A ... 1200 A Velikost : 400 Tolerance at set current: L: tripping between 1.05 and 1.2x IR S: - 0 %, +20 % I: - 0 %, +20 % G: - 0 %, +20 % Tripping time tolerance: L: - 20 %, + 0 % for characteristic I2t S: - 0 %, + 60 ms or –0 %, +10 % for characteristics with fixed delay I: < 50 ms G: - 0 ms, + 60 ms or –0 %, +10 % for characteristics with fixed delay 10000 100000 A 1) Size I and II: I100 ... 1200 A Velikost and II : 100 78 0,1 . ... 0,5 . s 0,1 . 1,5 . x n ... 0,8 . x cs 0,1 . Arion Technical information 3P 4P OVERCURRENT RELEASES - ETU76B Description Use Overcurrent release with versatile options for network analysis with graphic display. Up to 6300 A. Properties adjustable overload protection with characteristic I2t or I4t with fixed adjustable delay time 2 ÷ 30 s for I2t at 6x IR, 1 ÷ 5 s for I4t at 6x IR short-time delayed short-circuit protection, adjustable to 1.25x In ÷ 0.8x Icw instantaneous short-circuit protection set from 1.5x In ÷ 0.8x Ics, max. 100 kA overload signalling LED signalling of tripping cause possible overcurrent release testing function protective function setting by rotary switch adjustable delay class for overload protection switchable characteristics I2t and I4t in overload area and in the area of short-time delayed short-circuit protection for better current selectivity with assigned fuses or circuit breakers thermal memory, which is used for protection at the circuit breaker reclosing after switching off by overload – it can be disabled possible protection of N conductor (separately adjustable) optional earth fault protection module with separately adjustable alarm signalling and tripping functions possible connection of data communication and measuring function Plus recognition of energy flow direction two parameter sets, stored in the electronic release memory (switching over by an external signal or directly on the overcurrent release) switchable overload protection for protection of modern drives adjustable delay of short-circuit protection up to 4000 ms adjustable protection of N conductor up to IN = 2x In protective function setting by means of data communication graphic presentation of all parameters and events and curves storage of events and tripping causes for specific fault analysis high contrast backlit graphic display with quiet mode Option: safety lock, prevents from pressing of reset push-button after switching off by overcurrent Mechanical reset of reclosing blocking Graphic display Signalling: overcurrent release activated Alarm signalling: overload COMMUNICATION EXTENSION F. Signalling of release tripping cause Control push-buttons for setting of release parameters Rating Plug Signalling: faulty overcurrent release Rated current module Optional earth fault protection module Field for designation of set values Test push-button Query push-button Alarm signalling at earth fault Signalling: tripping by earth fault Field for designation of set values Reset push-button Test connector For other technical data see the table on page 72. Function 79 Arion Technical information 3P 4P OVERCURRENT RELEASES - ETU76B Tripping characteristic Function L 4 R 0,4 . ... 1,0 . x 1000 = const n 2 10000 NSE0_01526 10000 NSE0_01522 Function S 1000 sd = const . x n ... 0,8 . x cw 1,25 100 100 R 2 ... 30 for 2 1 ... 5 for 4 10 10 2 1 1 sd . 0,1 0,1 . = const sd = const . ... 0,4 . s 0,1 . ... 4 s 0,02 . 0,01 0,01 . 0,1 . 1 10 0,1 . 100 1 / n 1 / cw Function G NSE0_01524 10000 1000 10000 NSE0_01525 Function I 10 / n 1000 100 100 g 10 10 100 ... 1200 A 1) 1 1 i g 0,01 . . 0,01 . 0,1 1 10 100 100 1000 / n ... 1200 A Size III: 400 ...III1200 A ... 1200 A Velikost : 400 Tolerance at set current: L: tripping between 1.05 and 1.2x IR S: - 0 %, +20 % I: - 0 %, +20 % G: - 0 %, +20 % Tripping time tolerance: L: - 20 %, + 0 % for characteristic I2t S: - 0 %, + 60 ms or –0 %, +10 % for characteristics with fixed delay I: < 50 ms G: - 0 ms, + 60 ms or –0 %, +10 % for characteristics with fixed delay 10000 100000 A 1) Size I and II: I100 ... 1200 A Velikost and II : 100 80 . s 0,1 . ... 0,5 . 0,1 . x n ... 0,8 . x cs 1,5 0,1 . Arion Technical information 3P 4P OVERCURRENT RELEASES - EARTH FAULT MODULE Description The earth fault protection module measures earth fault current. Adjustable delay (time lag) enables selective sequencing of more circuit breakers. On the module it is possible to select the function of signalling or tripping (Alarm/Trip) at exceeding of a set limit of the earth current. By pressing the Query push-button the tripping cause is indicated by LED. In the overcurrent release ETU27B the earth fault protection module is integrated. Releases ETU45B, ETU55B and ETU76B are available in two variants. Without earth fault protection module or with integrated earth fault protection module. For other technical data see the table on page 72. Method of measuring 1. Vectorial sum of currents Overcurrent release measures currents in all three phases and also in N conductor and evaluates earth fault current by means of vectorial addition of these currents. 3-pole circuit breakers must be completed by an external measuring current transformers for N conductor see page 40. 4-pole circuit breakers must be equipped with an internal current transformer for N conductor, see page 28. 2. Direct measuring of earth fault current Direct measuring of earth fault current is performed by measuring current transformer with ratio 1200 A/1A and class of accuracy 1. Internal resistance of the circuit for the measuring current transformer connection is 0.11 Ohm. The measuring current transformer is installed on the earth conductor of the (power) transformer unit. Setting For ETU27B and ETU45B release the earth fault protection module is set by switches. For ETU76B it is set via menu or communication. Ft is possible to set: earth fault measuring mode limits for signalling and switching off of earth fault earth fault tripping delay Earth fault protection with characteristic I2t All releases - except ETU27B - have switchable characteristic I2t = constant. The use of this characteristic reduces thermal load f protective conductor PE at short-circuit. Setting range Ig A B C D E Circuit breaker size I and II III 100 A 400 A 300 A 600 A 600 A 800 A 900 A 1000 A 1200 A 1200 A Earth fault measuring mode switch GFM AT 45B Alarm signalling of earth fault Earth fault measuring mode switch Signalling tripping by earth fault Rotary switch setting the limits of tripping at earth fault Rotary switch of earth fault protection delay tg / I2tg Rotary switch setting the limits of alarm at earth fault Earth fault protection module GFM AT 76B Alarm signalling of earth fault Field for designation of the set measuring mode Signalling tripping by earth fault Field for designation of set limits Field for designation of set limits 3-pole circuit breaker, measuring current transformers on N conductor, vectorial sum of currents Arion 3-pole circuit breaker, measuring current transformer on earth conductor of the transformer unit, direct measuring Arion 4-pole circuit breaker, measuring current transformer on earth conductor of the transformer unit, direct measuring Arion 81 Arion Technical information MEASURING AND DATA COMMUNICATION 3P 4P Description BDA BDA Plus BSS ETU Measuring function Plus ZSS module COM15 Module with digital inputs Output device e.g. notebook Module with analog outputs The circuit breaker equipped with data communication enables: remote control setting of overcurrent release parameters state monitoring transfer of measured values Ethernet/ Intranet/ Internet PC with program Switch ES Power parameterization and visualization by means of PROFIBUS Module with digital outputs Data communication Data communication can be implemented via PROFIBUS or MODBUS protocol. Values can be obtained also in analog form via CubicleBUS module. Another method of transfer of the measured value is via BDA adapter with Ethernet protocol. This makes it possible to view the values on a standard PC. This solution is intended above all for service actions. PLC SIMATIC S7 data acquisition and processing Module with configurable digital outputs Measuring Circuit breaker equipped with relevant modules can measure electrical quantities in the protected circuit. E.g. current, voltage or power output. The values can be displayed directly on the overcurrent release display or transferred by means of data communication. GDS files necessary for control unit programming will be delivered on request. Measuring Measuring variants and properties Variant Standard variant – without measuring function Plus Extended variant – with measuring function Plus Current, voltage, power output (active, apparent, reactive), Energy, Cos φ, frequency, harmonic analysis Measured quantities Current - displays instantaneous value and records minimum and maximum value - enables storage of behaviour (curves) of current and voltage in the memory 3) - signals exceeding of the set limits of measured quantities 3) - extends protective functions 3) Necessary circuit breaker equipment Overcurrent release ETU45B or ETU76B Measuring function Plus No – current measuring is standard function of the release ETU45B, ETU76B ETU45B or ETU76B Yes Measuring voltage transformers No Yes Power supply No Yes Local Yes – on the overcurrent release display 2) Yes – on the overcurrent release display 2) Remote (PC, PLC, analog measuring instruments) Yes – the circuit breaker must be equipped with data communication PROFIBUS, MODBUS, CubicleBUS or with BDA adapter Yes – the circuit breaker must be equipped with data communication PROFIBUS, MODBUS or CubicleBUS Display of measured values Type designation for ordering Component/module type designation/complement code type designation/complement code ETU45B without display 1) ARION WL1-EB- Overcurrent release ETU45B with display ARION WL1-FB- ETU76B ARION WL1-NB- ARION WL1-EB- ARION WL1-FB- ARION WL1-NB- Measuring function Plus No „F05“ Measuring voltage transformers for 400 V a.c. No 3WL9111-0BB68-0AA0 Power supply No 6EP1333-2AA01 1) The circuit breaker must be equipped with data communication PROFIBUS, MODBUS or CubicleBUS for transfer and display of measured values. 2) The circuit breaker must be equipped with overcurrent release EtU45B with display or EtU76B with graphic display. 3) Detailed information about measuring function Plus will be delivered on request or see „Detailed Instructions for Use“ at www.oez.com. 82 Arion Technical information MEASURING AND DATA COMMUNICATION 3P 4P Data communication - PROFIBUS, MODBUS, BDA adapter Data communication methods and properties Method of data communication Communication protocol Connectible display and control devices SW of connected PC HW of PC Necessary circuit breaker equipment Overcurrent release Power supply Communication module Circuit breaker control Circuit breaker ON/OFF Reset of signalling „switched off by overcurrent release“ Free user digital output ON/OFF Signalling of circuit breaker state Circuit breaker state ON/OFF Switched off by overcurrent release Circuit breaker position in the withdrawable device Disconnected by undervoltage release Ready-to-close Storage device state Ready-to-close Monitoring of input state of CubicleBUS module with digital inputs Parameter setting Change of parameters of protective functions 2) Parameter set switching 2) Maintenance information reset Reset of minimum and maximum measured values Event memory and behaviour memory clearing Setting of limits for measured value exceeding alarm *) Setting of parameters of extended protective functions *) Reading of parameters Reading of event protocol Reading of overcurrent release tripping protocol Download of protective function parameters Contact wear Circuit breaker identification Number of pressing for storage device loading, number of operating hours Number of switching off by release (function L, S, I total) Download of limits for measured value exceeding alarm *) Download of parameters of extended protective functions *) Download of record of current and voltage behaviour *) Alarms Alarm of switching off by overcurrent release with breaking current value/including time Alarm with information of its start and end/including time Alarm of exceeding of limits of measured value *) Measured quantities Current in all phases including max. and min. value/including time Temperature in the circuit breaker including max. and min. value/including time Temperature in the switchboard including max. and min. value/including time Current, voltage, power output (active, apparent, reactive), energy, Cos φ, frequency, harmonic analysis including max. and min. value *) PROFIBUS PROFIBUS PC, PLC - e.g. SIMATIC S7 6GK1704-5DW08-1AA0 - SIMATIC NET PB SOFTNET-DP 6GK1571-1AA00 - USB adapter MODBUS MODBUS On request On request BDA adapter Ethernet PC Internet Explorer + JAVA 2 Virtual Machine On request network card or port RS232 ETU45B, ETU76B Yes COM15 3) ETU45B, ETU76B Yes COM16 3) ETU45B, ETU76B Yes 4) BDA adapter 3) Yes Yes 5) Yes Yes Yes 5) Yes Yes 1) Yes 5) Yes 1) Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 6) Yes 6) Yes 1) 6) No Yes 6) Yes 6) Yes 6) Yes 6) Yes 2) Yes 2) Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 1) Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 1) Yes 1) Yes Yes 6) Yes Yes 1) Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes/No Yes/No No Yes Yes Yes Type designation for ordering Component/module Overcurrent release ETU45B without display ETU45B with display ETU76B type designation/complement code ARION WL1-EB- ARION WL1-FB- ARION WL1-NB- „F02“ included „F02“ 6EP1333-2AA01 type designation/complement code ARION WL1-EB- ARION WL1-FB- ARION WL1-NB- „F12“ included „F12“ 6EP1333-2AA01 type designation/complement code ARION WL1-EB- ARION WL1-FB- ARION WL1-NB- 3WL9111-0AT33-0AA optional „F01“ 6EP1333-2AA01 4) Data communication BSS module Source *) Only for circuit breaker equipped with measuring function Plus, see page 82. 1) Only if the circuit breaker is equipped with data communication PROFIBUS or MODBUS. 2) Only with ETU76B. 3) COM15 is the module of data communication via protocol PROFIBUS, COM16 is the module of data communication via protocol MODBUS, BDA adapter is the module of data communication via protocol ETHERNET. 4) Only if power supply is not provided for data communication or measuring function Plus. 5) The circuit breaker must be equipped with remote and automatic reset see page 28. 6) The circuit breaker must be equipped with BSS module see page 28. 83 Arion Technical information MEASURING AND DATA COMMUNICATION 3P 4P Data communication - CubicleBUS Module with digital outputs 6 digital outputs outputs by means of relays or optical elements outputs can be assigned to selected circuit breaker state signals output assignment by means of rotary switch max. 2 modules can be connected to the circuit breaker 3WL9111-0AT26-0AA0 – relay outputs Module with configurable digital outputs 6 digital outputs outputs by means of relays or optical elements outputs can be assigned to selected circuit breaker state signals max. 1 module can be connected to the circuit breaker configuration by means of BDA adapter or PC with software „ES Switch Power“ via PROFIBUS 3WL9111-0AT20-0AA0 – relay outputs Module with analog outputs four analog outputs (3 phases + N-pole) at a time it can transfer one selected measured quantity with values in all three phases and N pole possibility of selection of analog output type 0 ÷ 10 V or 4 ÷ 20 mA selection of quantities to be transferred and selection of analog output type is possible by means of rotary switch max. 2 modules can be connected to the circuit breaker 3WL9111-0AT23-0AA0 Module with digital inputs module has two modes control voltage 24 V d.c. max. 2 modules can be connected to the circuit breaker one in mode 1 and the other in mode 2 MODE 1: user inputs transferred via protocol PROFIBUS or Ethernet (BDA adapter) - 6 digital inputs MODE 2: switching of overcurrent release parameter sets (for ETU76B) - 1 digital input 3WL9111-0AT27-0AA0 ZSS module – time shortened selectivity control 3WL9111-0AT21-0AA0 at connection of circuit breakers Arion at more levels it ensures full selectivity at short-circuit protection ensures as short breaking time as possible in case of short-circuit all controlled circuit breakers must be equipped with one ZSS module At short-circuit in the protected circuit, the affected circuit breaker sends “shortcircuit protected” alarm. Consequently, the system can determine the place of short-circuit, and disconnect the circuit breaker, which is closest to the shortcircuit in the energy flow direction. Higher-level circuit breakers are in standby mode. If the circuit breaker, which is closest to the short-circuit, does not send the information of the short-circuit (for example, the circuit breaker is set incorrectly), the short-circuit will switch off the closest higher-level circuit breaker immediately, without waiting for expiration of selectivity time. Detailed information about CubicleBUS modules will be delivered on request or see „Detailed Instructions for Use“ at www.oez.com. Parameters of CubicleBUS modules Name Module with digital outputs Type designation 3WL9111-0AT26-0AA0 Function digital outputs Number of inputs – Number of outputs 6 Output/input type digital Rated operating current Ue Relay output 84 AC-15 DC-13 6 A/250 V a.c. 2 A/24 V d.c., 0.2 A/250 V d.c. Module with configurable digital outputs 3WL9111-0AT20-0AA0 programmable digital outputs – 6 digital Module with analog outputs Module with digital inputs ZSS module 3WL9111-0AT23-0AA0 analog outputs – 4 (3f + N) analog 3WL9111-0AT27-0AA0 digital inputs 6/1 according to mode, see the text – digital 3WL9111-0AT21-0AA0 time shortened selectivity control – – – 6 A/250 V a.c. 2 A/24 V d.c., 0.2 A/250 V d.c. – – – – – – Technical information Arion AUXILIARY SWITCHES, SIGNAL SWITCHES 3P 4P Description Auxiliary switches The switches signal always the state of main contacts of the circuit breaker. Each circuit breaker is equipped with auxiliary switch with two make and break contacts. The circuit breaker can by completed by additional switch. Specifications Signal switch „switched off by overcurrent release“ – designation in the diagram: S24 This switch signals the circuit breaker disconnection by overcurrent release due to overload, short-circuit or earth fault. The signal switch is optional accessory. If the circuit breaker is equipped with data communication, this switch is standard accessory. Signal switch “ready-to-close” – designation in the diagram: S20 Circuit breakers are standardly equipped with an optical indicator of readiness to closing. The switch enables repote signalling„ready-to-close“. The signal switch is optional accessory. If the circuit breaker is equipped with data communication, this switch is standard accessory. Auxiliary switches – designation in the diagram: S1, S2, S3, S4, S7, S8 Rated operating voltage Ue Rated insulation voltage Ui Rated frequency fn Rated operating current Ie AC-12 AC-15 DC-12 DC-13 500 V a.c./d.c. 500 V a.c/d.c. 50/60 Hz 10 A/24 ÷ 500 V 4 A/24 ÷ 230 V, 3 A/400 V, 2 A/500 V 10 A/24 V, 8 A/48 V, 3,5 A/110 V, 1 A/220 V 8 A/24 V, 4 A/48 V, 1,2 A/110 V, 0,4 A/220 V Signal switch of the storage device state – designation in the diagram: S21 Circuit breakers are standardly equipped with an optical indicator of storage device state. The switch enables remote signalling, whether the storage device is loaded up or released. The signal switch is optional accessory. If the circuit breaker is equipped with data communication, this switch is standard accessory. Specifications Signal switche Rated operating voltage Rated insulation voltage Rated frequency Rated operating current Ue Ui fn Ie AC-12 DC-12 250 V a.c./d.c. 440 V a.c./250 V d.c. 50/60 Hz 8 A/250 V 6 A/24 V, 0,4 A/125 V, 0,2 A/250 V Diagram see page 51 85 Arion Technical information SHUNT TRIPS, AUXILIARY POWER SOURCES FOR SHUNT TRIPS 3P 4P Description Shunt trip Shunt trip causes immediate disconnection of the circuit breaker when voltage is applied on it. The shunt trip is delivered in the version for short-time excitation (overexcitation) with load factor 5 % and in the variant for continuous excitation with load factor 100 %. Continuously excited overcurrent release enables circuit breaker blocking in disconnected state and blocking of eventual circuit breaker reclosing. It is possible to buy an auxiliary power source for shunt trip, which enables circuit breaker disconnection at interruption of control circuit power supply. Specifications Shunt trip – designation in the diagram: F1, F2 Load factor Rated operating voltage Ue for 100 % 110, 230 V a.c. 24, 30, 48, 60, 110, 220 V d.c. 50/60 Hz Rated frequency fn Input power 15 W/15 VA Characteristic U>= 0.7 Ue circuit breaker must be switched off Control pulse min. 60 ms Time to switching 80 ms Protection Circuit breakers for AC LPN-1C-1 Circuit breakers for DC LPN-DC-2C-1 Loading time ∞ Shunt trip signal switch – designation in the diagram: S22 or S23 250 V a.c./d.c. Rated operating voltage Ue 440 V a.c./250 V d.c. Rated insulation voltage Ui 50/60 Hz Rated frequency fn 8 A/250 V Rated operating current Ie AC-12 DC-12 6 A/24 V, 0.4 A/125 V, 0.2 A/250 V Auxiliary power sources for shunt trips Operating voltage Type Maximum power supply time Auxiliary release signal switch Shunt trip state is signaled by the auxiliary signal switch. Diagram see page 51 110 V a.c./d.c. 230 V a.c./220 d.c. 3WL9111-0BA13-0AA0 3WL9111-0BA14-0AA0 UNDERVOLTAGE RELEASES Auxiliary release signal switch Undervoltage release state is signaled by the auxiliary signal switch. Specifications Undervoltage release – designation in the diagram: F3, F4 110 , 230 V, 400 V a.c. Rated operating voltage Ue 241), 301), 48, 110, 220 V d.c. 50/60 Hz Rated frequency fn Input power 5 W/5 VA (holding 200 W/200 VA) Characteristic U>=0.85 Ue circuit breaker can be switched on U<= 0.35 Ue circuit breaker must be switched off Control pulse min. 60 ms Time to switching off 80 ms Protection Circuit breaker LPN-1C-1 Undervoltage release signal switch – designation in the diagram: S23 250 V a.c./d.c. Rated operating voltage Ue 440 V a.c./250 V d.c. Rated insulation voltage Ui 50/60 Hz Rated frequency fn AC-12 8 A/250 V Rated operating current Ie DC-12 6 A/24 V, 0.4 A/125 V, 0.2 A/250 V 1) - only for short-time delayed undervoltage release Combinations of auxiliary releases Diagram see page 51 86 A No No 3s 3P 4P Undervoltage release Undervoltage release causes instantaneous disconnection of the circuit breaker at drop of control voltage of the release under a specified limit or at full loss of voltage. If the undervoltage release is not excited, it is not possible to switch on the circuit breaker mechanically or electrically. The undervoltage release is delivered in two variants. Short-time delayed with delay of 80 or 200 ms and long-time delayed with delay of 0.2 to 3.2 s. Combination 25 ms 50 ms 5 min from failure 5 min from failure Description Auxiliary release 1st auxiliary release 2nd auxiliary release for 5 % B Shunt No C No Shunt D Shunt Shunt E No Undervoltage F Shunt Undervoltage Arion Technical information LOCKING AND BLOCKING DEVICES 3P 4P Description tive only with the circuit breaker switched off and the key withdrawn. The key can be withdrawn only in position “OFF”. With the circuit breaker “ON” the locking device is blocked. Locking device against unauthorized closing This function prevents from circuit breaker closing and meets the requirements of EN 60 204 (VDE 0113) for safe disconnection from the network. The locking device is effective only on given circuit breaker. After circuit breaker replacement, the closing is not prevented until the new circuit breaker is locked against unauthorized closing. After activation of the locking device the circuit breaker must be switched off. The lock is effective only with withdrawn key. The key can be withdrawn only in position “OFF”. With the circuit breaker “ON” the locking device is blocked. Protective caps for mechanical ON/OFF They prevent from unauthorized closing/opening of the circuit breaker on the control panel. For the variant with locking by means of a safety lock, it is only possible to press the push-buttons, if the key is inserted. The circuit breaker can be switched ON/OFF remotely. The lock is effective only with withdrawn key. For the variant with locking by means of a padlock, the push-buttons are covered by the caps with hole of diameter 6.5 mm. The holes enable the circuit breaker control by means of a special tool. Locking device against unauthorized closing, independent of the circuit breaker This special function for withdrawable circuit breakers prevents from circuit breaker closing, is independent of the circuit breaker, and meets the requirements of EN 60 204 (VDE 0113) for safe disconnection from the network. It prevents from unauthorized closing of the circuit breaker also after its replacement by other circuit breaker. The locking is effec- Locking devices of the storage device lever The storage device hand drive lever can be locked by a padlock. After it, it is not possible to wind up the storage device by the lever. Mechanical interlocking Mechanical interlocking can block 2 or 3 circuit breakers/ switch-disconnectors. The mechanical interlocking is solved by means of Bowden cables. It is possible to interlock circuit breakers and switch-disconnectors of both fixed and withdrawable design. For example, it is possible to block 3 devices: 2 circuit breakers of withdrawable design and one switch-disconnector of fixed design. Mechanical interlocking is only functional if the circuit breaker of withdrawable design is in operating position. The distance between blocked circuit breakers/switchdisconnectors is given by the length of the used Bowden cables. Circuit breakers/switch-disconnectors can be installed next to each other or above each other. Circuit breakers/ switch-disconnectors equipped with mechanical interlocking are standardly equipped with 2 m Bowden cables. It is possible to buy separately Bowden cables of the length 2 m, 3 m or 4.5 m. At use of mechanical interlocking for three circuit breakers/switch-disconnectors, it is necessary to order to each circuit breaker/switch-disconnector separately one additional Bowden cable of relevant length. Mechanical endurance of the mechanical interlocking is 10 000 cycles. Conditions of use and correct function of mechanical interlocking: Bowden cables must be, if possible, led straight, without undue bends bend radius of the Bowden cable must be higher than 500 mm the sum of all bend angles of the Bowden cable must not be higher than 640° at arrangement of the interlocked circuit breakers/ switch-disconnectors above each other the interlocking mechanismus must be in row above each other Locking devices against shifting It prevents from withdrawal of the crank for circuit breaker shifting. The circuit breaker is thus secured against withdrawing. The lock is effective only with withdrawn key. Blocking device against shifting of the circuit breaker at opened switchboard door The crank for circuit breaker withdrawing/inserting is blocked and cannot be withdrawn. Circuit breaker cannot be moved. The blocking is effective only with the crank inserted. Blocking device against switchboard door opening Blocking is transferred by Bowden cable. Ft is not possible to open the switchboard door, if: fixed circuit breaker is switched on withdrawable circuit breaker in operating position the distance between the blocked circuit breakers/switch- disconnectors is given by the length of the Bowden cables which must be led according to the mentioned rules Bowden cables must be fixed in the switchboard already before mechanical interlocking setting fixed Bowden cables must not prevent circuit breaker/ switch-disconnector handling or switchboard door opening Example of possible interlocking Max. 1 circuit breaker can be switched on Max. 2 arbitrary circuit breakers can be switched on Max. 1 circuit breaker can be switched on 2 transformers or only generator can be switched on G S1 S2 S1 S2 NSE01041 NSE01042 G G S3 S1 S1 NSE01043 S2 S2 Transformer and generator are blocked S3 S1 S3 S2 S3 NSE01044 NSE01045 For other information see detailed instructions for use at www.oez.com. 87 Arion Technical information DRIVES AND CLOSING RELEASES 3P 4P Description Hand drive Each circuit breaker is equipped with the hand drive. Hand drive lever is used for mechanical loading of the storage device. Motor drive It is used for automatic loading of the storage device of the closing mechanism. The motor drive is switched on automatically, if the storage device is not loaded(if supply voltage is applied). After storage device loading, the motor drive is switched off automatically. Manual storage device loading by a lever is independent of the motor drive. Motor drive switch It switches the motor drive off. Operating cycle counter The circuit breaker with the motor drive can be equipped with 5-place cycle counter. The counter adds „1” after each full storage device loading. Closing release It enables local (by electrical ON push-button on the front control panel) or remove switching the circuit breaker on by electrical pulse. The closing release is delivered in the version for short-time excitation (overexcitation) with load factor 5 % and in the version for continuous excitation with load factor 100 %. Circuit breakers switching on by means of mechanical “ON” push-button on the front panel of the circuit breaker is independent of the closing release. Diagram see page 51 88 Specifications Hand drive Number of lever pressing for full storage device loading Control force Motor drive Rated operating voltage Ue Rated frequency fn Input power Time to storage device loading Protection Closing release Load factor Rated operating voltage Rated frequency Input power Control pulse Time to switching Protection Ue fn Ie 9 230 N 24 ÷ 60 V 110 ÷ 230 V for 100% 110 , 230 V a.c. 241), 301), 48, 60, 110, 220 V d.c. 50/60 Hz 15 W/15 VA min. 60 ms 80 ms Circuit breakers for AC LPN-1C-1 Circuit breakers for DC LPN-DC-2C-1 Loading time 1) 110 , 230 V a.c. 24, 301), 48, 601), 110, 220 V d.c. 50/60 Hz 110 W/110 VA ≤ 10 s PVA10 2A gG, LPN-2C-1 LPN-1C-1 Only for release with load factor 100 %. ∞ for 5% 25 ms 50 ms 3s Arion Technical information GLOSSARY OF TERMS Note: Precise wording of definitions and texts relating to a given term are detailed in the respective standards (see Name). Name Symbol Explanation Rated operating voltage EN 60947-1; 4.3.1.1 Ue Voltage fixed by the manufacturer. Several pertinent tests relate to its determination, as may also the utilization category. Along with the rated (operating) current, it determines the device’s utilization. The highest value of rated operating voltage may in no case be greater than the value of the rate insulation voltage Ui. Rated insulation voltage EN 60947-1; 4.3.1.2 Ui Voltage measure to which are related tests of dielectric strength and creepage distance. Rated current EN 60947-2; 4.3.2.3 In Current value of particular circuit breaker that can be handled uninterruptedly. The highest current valued tripping the circuit breaker in conformity with a specifically stated tripping characteristic. Reduced rated current IR Specifically established, reduced value of In current for a regulated time-dependent (thermal) release and that the circuit breaker can handle continuously. Maximum setting is at value equal to In. Changing IR shifts the release’s tripping characteristic along the current axis. (IR = k x In holds where k ≤ 1) Tripping time at a given Ir multiple tR Time after which circuit breaker will trip, if a current flows through it that is equal to the given multiple of IR. Changing tR shifts the tripping characteristic along the time axis. Actuating current of (selective) release’s time-independent delay Isd Minimum current value causing the release’s time-independent delay to actuate. Delay of time-independent delayed release tsd If a current flows through the circuit breaker equal to at least Isd but not reaching Ii the circuit breaker will trip with time delay tsd. Total shut-off time is influenced by the tripping of the circuit breaker itself and is about 10 ÷ 20 ms longer. Actuating current of time-independent instantaneous (short-circuit) release Ii Minimum current value causing the time-independent instantaneous release to actuate. Rated operating current EN 60947-1; 4.3.2.3 Ie Rated operating current of device (switch-disconnector) is fixed by the manufacturer with consideration for the rated operating voltage, rated frequency, rated operation, utilization category and type of protective cover, if that comes into consideration. Rated normal current EN 60947-1; 4.3.2.4 Iu Current value set by the manufacturer and which the device can handle in continuous operation, i.e. during a period longer than 8 hours (weeks, months, or longer). Rated ultimate short-circuit breaking capacity EN 60947-2; 2.15.1; 4.3.5.2.1 Icu Ultimate short-circuit breaking capacity value expressed as the rms value of the alternating component of the assumed short-circuit current that the circuit breaker must be able to manage in the mode: 1x switching off of the short circuit and a following 1x make-break sequence. After testing, the circuit breaker need not be able to conduct the rated current uninterruptedly. Icu is set for the rated operating voltage at the rated frequency and at the established power factor for alternating current or at the time constant for direct current. Must fulfil the condition: Icu ≥ Ik“ Rated short-circuit service breaking capacity EN 60947-2; 2.15.2; 4.3.5.2.2 Ics Value of the operating short-circuit breaking capacity expressed as the rms value of the alternating component of the assumed short-circuit current that the circuit breaker must be able to manage in the mode: 1x switching off of the short circuit and a following 2x make-break sequence. May also be expressed as a percentage of Icu. After testing, the circuit breaker must be able uninterruptedly to conduct the rated current and to switch off the overcurrent. Temperature increase of the main terminals may be greater. Ics is set for the rated operating voltage at the rated frequency and at the established power factor for alternating current or at the time constant for direct current. Permitted: Ics ≥ Ik“ Rated short-time withstand current EN 60947-1; 4.3.6.1 EN 60947-2; 4.3.5.4 EN 60947-3; 4.3.6.1 Icw Value of short-time withstand current specified by the manufacturer that the device is able to handle without damage during a designated time period (short-time delay). In case of alternating current, it is the rms value of the alternating component of the assumed short-circuit current Ip. Rated conditional short-circuit current EN 60947-1; 4.3.6.4 EN 60947-2; Supplement L; L.4.2 Icc The prospective short-circuit value given by the producer that can be transferred by the device, protected against short-circuit by protective device, within its operation. Must fulfil the condition: Icc ≥ Ik“ 89 Arion Technical information GLOSSARY OF TERMS Note: Precise wording of definitions and texts relating to a given term are detailed in the respective standards (see Name). Name Symbol Explanation Rated short-circuit making capacity EN 60947-1; 4.3.6.2 EN 60947-2; 4.3.5.1 EN 60947-3; 4.3.6.2 Icm Value of short-circuit making capacity specified by the manufacturer for the rated operating voltage at the rated frequency and at the established power factor for alternating current or at the time constant for direct current. It is expressed as the maximum assumed peak current. Must fulfil the condition: Icm ≥ ip Initial peak short-circuit current EN 60909-0; 1.3.5 Ik“ Short-circuit current value at the moment of its arising at a given point in the electrical distribution expressed as the rms value of the alternating symmetrical component of the assumed short-circuit current. Surge short-circuit current EN 60909-0; 1.3.8 ip Maximum possible momentary value of the assumed short-circuit current. (Corresponds to the moment the short arises, as a result of which there occurs the peak value of the short-circuit current.) Prospective short-circuit current EN 60947-1; 2.5.5 EN 60909-0; 1.3.3 Ip Short-circuit current value, which would flow through the circuit if the protection device were replaced and a short circuit were experienced by conductors with negligible impedance. (In a three-phase distribution, it is assumed that the short circuit is simultaneous in all phases.) Rated pulse withstand voltage EN 60947-1; 4.3.1.3 Uimp Peak value of the voltage impulse of the prescribed form and polarity which the device is able to withstand without failure at the established conditions and pertinent to which is the value of the separating air distance. Uimp of the device must be equal to or higher than the value established for momentary overvoltage at the point in the circuit (overvoltage category) where the device is used. Overvoltage category EN 60947-1; 2.5.60 Rated frequency EN 60947-1; 4.3.3 Numerically defined level of momentary overvoltage, i.e. overvoltage having its origin in atmospheric or switching. Standard EN 60664-1 establishes for electrical equipment the overvoltage categories: Overvoltage category IV - service entrance, outside lead Overvoltage category III - fixed wiring Overvoltage category II - appliances Overvoltage category I - light-current appliances fn Frequency of the supply network for which the device is proposed and that corresponds to its other characteristics values. Utilization category (circuit breakers - timing selectivity) EN 60947-2; 4.4 Utilization category of circuit breaker establishes whether or not the circuit breaker specifically is intended for providing selectivity by means of intentional time delay (timing selectivity) with other protective devices connected in series on the load side in short-circuiting conditions. Utilization category: A - circuit breakers are not specifically intended for providing timing selectivity B - circuit breakers are specifically intended for providing timing selectivity Utilization category (switch-disconnectors - switching mode) EN 60947-3; 4.4 Utilization category defines the assumed use of switch devices (switch-disconnectors). Characterised by values of current and voltage, expressed as multiples of rated operating current and rated operating voltage, and further by power factors or time constants of the circuit. Utilization category: AC-21B (DC-21B) - infrequent switching of resistive loads, including moderate overloading AC-22B (DC-21B) - infrequent switching of mixed resistive and inductive loads, including moderate overloading AC-23B (DC-23B) - infrequent switching of motor loads or other highly inductive loads. Pollution degree EN 60947-1; 2.5.58; 6.1.3.2 Pollution degree relates to the conditions of the surrounding environment for which the device is intended. Pollution degree: 1 - No contamination will occur, or only dry, non-conducting contamination. 2 - Normally occurs only non-conducting contamination, but sometimes there may occur temporary conductibility due to condensation. 3 - There occurs conductive contamination or dry non-conducting contamination that with the effect of condensation will become conductive. 4 - Contamination generates continuous conductibility, by means of, for example, conductive dust, rain or snow. 90 Technical information Arion NOTES 91 Arion NOTES 92 Technical information OEZ s.r.o. Šedivská 339 561 51 Letohrad Czech Republic tel.: +420 465 672 111 +420 465 672 101 fax: +420 465 672 398 +420 465 672 151 e-mail: oeztrade.cz@oez.com www.oez.com www.oez.com www.oez.com VJ1-2012-A Any changes reserved Arion Air circuit breakers