Hoist Push-Button Switches

advertisement
Hoist Push-Button Switches
COB 60 series
For Indirect Operation of Electrical Machinery
Outline
Power
Switches
The COB 60 series is a push button switch for indirect
operation via electro-magnetic switches. It is small, light,
and economical.
Basic type list
Type name
Button packing is included inside the case, built-in structure.
It is possible to manufacture types other that the standard
of cable bushing and character boards, etc. The attached
cable bushing of COB64 and COB66 is supposed to be
used for vinyl cabtire cable.
Hoist Push-Button
Switches
COB 61
COB 61W
COB 61UNB
COB 62
COB 62W
COB 62UNB
COB 63
COB 63W
COB 63UNB
2 (1 pair)
4 (2 pairs)
Built-in structure
6 (3 pairs)
Appearance
The standard case is made with high impact ABS, and is
light and safe with no risk of electrification.
The mechanical interlock is included for safety, so Up/Down
and East/West cannot be pressed at the same time.
COB61, COB 62, COB 63 have type attached with power
on/off unit which is convenient for opening/closing of the
main circuit and switch on/off of the light (COB61UNB,
COB62UNB, COB63UNB). The installing position of power
on/off unit is at the uppermost.
Operating Push
Button Switches
Using twin contact, we also have available a type built in
with a switch unit that can correspond to a minute load
(COB61W, COB 62W, COB 63W, COB 64W, COB 65W).
The on/off switch is not twin contact. The contact reliability
of twin contact is confirmed and proven usable without
problems through the test using the circuit condition of DC
12V 10mA.
No. of buttons
Button packing
Prevention of
erroneous operation
Type name
With mechanical interlock
COB 64
COB 64W
COB 66
COB 66W
Appearance
Foot
Switches
No. of buttons
Button packing
Prevention of
erroneous operation
8 (4 pairs)
12 (6 pairs)
Built-in structure
With mechanical interlock
General specifications
Specifications
Item
Degree of
protection
Rating
Rating
IP65(JIS C 0920)
Electrical Appliance and Material Safety Law :Rainproof type
Material/ Color
Liquid Level
Relays
Case: Shockproof ABS Resin Note /
Orange (Munsell 7.5YR7/13 equivalent)
Case-tightening screws: Stainless (± screws)
Cable bushing: Synthetic rubber / Black
Vibration proof
Operational Tolerance 10 to 55Hz Displacement: 1.0mm
500m/s2
Durability
Shockproof
Operational Tolerance 100m/s2
Connected terminal M4 screws (Pressure terminal type)
Ambient
temperature
−15℃ to +40℃
(must be free of ice or condensation)
Relative humidity 45 to 85% RH
Installation
Must be installed with the cabtire cable slot
position
uppermost using appropriate cabtire cabling.
Specifications
220V AC 2A
Item
Voltage used/
Rated operating current
(Inductive load AC15)
440V AC 1A
Rated insulation voltage
Rated thermal current
Insulation resistance
Withstand voltage
500V AC
5A
100 MΩ or more (500 V DC Megger)
2500 V AC / minute
Remark : Rating in accordance with the Electrical Appliance and Material
Safety Law (250 V AC / 5 A) only is shown on the nameplate.
Compliance standards
Name of standards
JIS C 8201-5-1
NECA C4520
JIS C 0920
Electrical Appliance and Material Safety Law (compliant products)
Overseas standards (Production on demand)
File name
Name of standards
R9750209 (not applicable to COB66)
TÜV
2005010305168698 (not applicable to COB66)
CCC
17
Hoist Push-Button Switches
For Indirect Operation of Electrical Machinery
COB 60 series
Product List
No. of buttons
4
(2 pairs)
8
(4 pairs)
12
(6 pairs)
Note : Unit type name : UNB CH10
Hoist Push-Button
Switches
6
(3 pairs)
Type name
Power
Switches
2
(1 pair)
General
Included cable bushing Included markings board Contact arrangement
mass (g)
(Applicable cable diameter range)
Up, Down
230
−
COB 61
C125
1NO-1NO
For minute current
COB 61W
(φ11.4 to φ12.6)
To be specified
With On/Off switch COB 61UNB
1NO- Off
unit Note
U p , D o w n , E a s t , 1NO-1NO-1NO-1NO 340
−
COB 62
C15
West, South, North
(φ14.3 to φ15.5)
For minute current
COB 62W
To be specified
1NO- Off- 1NO- 1NO
With On/Off switch COB 62UNB
unit Note
U p , D o w n , E a s t , 1NO-1NO-1NO-1NO- 430
−
COB 63
C18
West, South, North 1NO-1NO
For minute current
COB 63W
(φ17.2 to φ18.4)
To be specified
With On/Off switch COB 63UNB
1NO- Off- 1NO- 1NOunit Note
1NO- 1NO
On, Off, Up, Down, 1NO- Off- 1NO- 1NO- 550
With On/Off switch COB 64
C17
East, West, South, 1NO- 1NO- 1NO- 1NO
unit Note
(φ15.7 to φ17.1)
North
For minute current
COB 64W
On, Off, Up, Down, East, 1NO- Off- 1NO- 1NO- 770
C18
With On/Off switch COB 66
West, South, North, Forward, 1NO- 1NO- 1NO- 1NOunit Note
(φ17.2 to φ18.4)
Backward, Left, Right
1NO- 1NO- 1NO- 1NO
For minute current
COB 66W
Characteristics
Option
It is dangerous to use the standard cable bushing included with this product with inappropriate cabling, as rainwater may
easily enter the switch. Please purchase the appropriate cable bushing.
Cable bushing
type name
Applicable cable
diameter range
φ7.5 to φ10.5
φ10.3 to φ13.5
φ13.3 to φ16.5
φ16.3 to φ19.5
Packing
Bush
(waterproof area) (protection area)
CC-A1
CB-A
CC-A2
CC-B1
CB-B
CC-B2
・Installation method for COB A1, A2, B1, B2 cable bushing
The cable is fed through the bushing holder, bushing, and packing in that
order, and the tightening screw used to secure the bushing holder firmly to
the case.Two packings are prepared as a set. Check the cable range
displayed on the packing, and separate off the applicable one.
In terms of C7 to C19 cable bushing, the bush and packing are integrated.
Liquid Level
Relays
Reference :
When inserting into the bushing, it is
recommended to lubricate the cable
and cable slot with wet soap to ease
insertion. Do not use lubricating oil,
as this may damage the bushing.
Cable bushing
type name
COB A1
COB A2
COB B1
COB B2
Foot
Switches
C7
C8
C9
C10
C12
C125
C13
C14
C15
C16
C17
C18
C19
Applicable cable
diameter range
φ6.8 to φ7.9
φ7.7 to φ8.8
φ8.9 to φ10.0
φ10.0 to φ11.0
φ10.6 to φ11.8
φ11.4 to φ12.6
φ12.3 to φ13.5
φ12.7 to φ14.1
φ14.3 to φ15.5
φ15.4 to φ16.6
φ15.7 to φ17.1
φ17.2 to φ18.4
φ18.4 to φ19.6
Operating Push
Button Switches
Cable bushing
18
Hoist Push-Button Switches
COB 60 series
For Indirect Operation of Electrical Machinery
Button Characters
An extensive range of markings boards is available in addition to the markings board included. Characters other than the
following can also be produced. Please contact us for further details.
Power
Switches
入 切 上 下 東 西 南 北 前 後 左 右 起 伏 伸 縮 正 逆 停 止 開 閉 非 警
高 低 元 先 陸 海 山 早 速 遅 吸 出 単 始 同 商 照 ラ ブ
補
上
補
下
巻
上
巻
下
両
上
両
下
片
上
片
下
上
昇
下
降
高
上
高
下
低
上
低
下
上
高
ブ
ザ
ラ
入
ブ
入
ブ
切
照
入
照
切
警
報
U
D U 1 U2 D 1 D2 E W S
下
高
正
転
逆
転
停
止
主
上
主
下
電
源
照
明
上
低
下
低
高
速
低
速
自
動
手
動
N
F
R
L
A
B FOR REV
STOP ON OFF UP DOWN EAST WEST SOUT NORT IN OUT INV COMM TILL
Hoist Push-Button
Switches
※1
STOP
※2
巻 戻
運
転
反
転
※3
戻
し
入 切 LEFT RIGHT STOP 切 非 レベル ロック
※4
※4
※4
※1 Plain red ※2 Red characters ※3 For engrared characters ※4 Black character on red background
Diagram of internal connections
COB 61, COB 61W
COB 62, COB 62W
COB 63, COB 63W
Down
Operating Push
Button Switches
1
Down
1
3
(West)
Down
2
3
1
(South)
3
(North)
3
2
1
2
1
3
3
2
1
3
2
1
3
2
1
3
2
1
3
Off
2
1
2
COB 66, COB 66W
2
1
2
1
2
COB 64, COB 64W
3
2
1
3
2
1
3
3
Connection cable
1.25 mm2, 3-core
Note :
Connection cable
1.25 mm2, 5-core
Note :
Connection cable
1.25 mm2, 7-core
Note :
Connection cable
1.25 mm2, 9-core
Note :
Connection cable Note :
1.25 mm2, 13-core
Dimensions (Unit: mm)
COB 61, COB 61W,
COB61UNB
COB 62, COB 62W,
COB62UNB
COB 63, COB 63W,
COB63UNB
COB 64, COB 64W
COB 66, COB 66W
φ
Foot
Switches
Note : If a different cable diameter is used, please purchase an appropriate cable bushing.
φ
φ
φ
φ
Liquid Level
Relays
19
Download