WAU KESHA ® COM PON E NTS 2 N D G E N E R AT I O N Positive Temperature Coefficient Heater S M A L L E R , FA S T E R , E A S I E R T E M P E R AT U R E C O N T R O L W I T H O U T A T H E R M O S TAT The Waukesha® Positive Temperature Coefficient heater (PTC2) can improve the reliability, efficiency and operational life of electrical equipment by automatically maintaining an enclosure temperature only slightly higher than the outside ambient temperature without using a thermostat or controls. Our PTC2 performs this function with a high velocity fan, all while taking up less space and having no need for any special mounting platforms. E LI M I NATE S TH E R M OSTAT PR OB LE M S Our PTC2 heaters use a variable resistance (current limiting) material that automatically controls cabinet temperature and eliminates the need for a thermostat, increasing heater reliability and efficiency. SEE BACK SIDE FOR PART NUMBER CONFIGURATION TOOL. PR EVE NTS H EAT DAMAG E AN D CON D E N SATI ON During cold weather when significant heat is required to reach the thermostat setting, a traditional strip heater is likely to drive the temperature of the area around the heater well above desirable levels. This can result in uneven heat distribution in the control box. Waukesha® PTC2 heaters feature an integral circulating fan that moves warm air around the cabinet, maintaining even heat distribution and providing uniform condensation protection. The PTC2 offers even better air velocity than the previous PTC, allowing for even more air movement throughout the cabinet. PTC2 heaters are available in the following configurations: •2 0, 30, 40 & 60 Watt — dual rated for 120V–240V • 200 Watt, Fan Forced* • 300 Watt, Fan Forced* • 400 Watt, Fan Forced* * Specify either 120V or 240V I N STALLS QU I CK LY The electrical connections from the fan to the heater are prewired, so the only connection necessary is to provide power to the assembly; our forced air PTC2 heaters include a 12 foot long wire harness with quick-connect end for easy installation. Integrated DIN-rail mounting clip allows for quick orientation in cabinet for proper air circulation. Snap-together connection between harness and heater further simplifies installation. AD D ITI ONAL FEATU R E S • Economical • Energy Efficient — Low Power Consumption • Low Electrical Noise • Low Profile — Compact Size • Plastic Heater Guard to Help Prevent Burns • UL Recognized TRANSFORMERS | SERVICE | TRAINING | COMPONENTS Build Your Own Part Number Using Configuration Below Build BuildYour YourOwn OwnPart PartNumber NumberUsing UsingConfiguration ConfigurationBelow: Below: NOTES: • “T emperature activated” PTC2 heaters are controlled by an internal set to energize at 5ºC±3ºC thermostat, •H i-recovery PTC2 heaters operate as a standard 200 or 300 watt PTC2 heater with a hi-recovery 400W mode activated by integral thermostat, set to energize at 5ºC±3ºC •U nits A, E, F and G are dual-rated for 120V–240V service; use “0” for dual voltage selection PPP TT CC 22 -- XX XX XX 20 WATT ASSY 2020 WATT WATT ASSY ASSY NATURAL CONVECTION NATURAL NATURAL CONVECTION CONVECTION EEE 3.193.19 SYSTEM SYSTEM TYPE TYPE SYSTEM TYPE F FF .41 .41 PTC24.26HEATER A & G SYSTEM TYPES 4.26 OPTION OPTION ADD ADD OPTION ADD 30 WATT ASSY 3030 WATT WATT ASSY ASSY NATURAL CONVECTION NATURAL NATURAL CONVECTION CONVECTION For ForMore MoreInformation Information MOUNTING: DIN RAIL 1.39 [35.3] VOLTAGE VOLTAGE VOLTAGE 4.694.69 5.445.44 40 WATT ASSY 4040 WATT WATT ASSY ASSY NATURAL CONVECTION NATURAL NATURAL CONVECTION CONVECTION GG G 60 WATT ASSY 6060 WATT WATT ASSY ASSY NATURAL CONVECTION NATURAL NATURAL CONVECTION CONVECTION AAA 200 WATT, W/FAN 200 200 WATT, WATT, W/FAN W/FAN FORCED CONVECTION FORCED FORCED CONVECTION CONVECTION BBB DIN RAIL MOUNT 00 2 110-120V 110-120V AC AC 110-120 VAC 0 00 DIN RAIL NONE NONE 1030-1342-001 220-240AC VAC 220-240V 220-240V AC 1 11 MOUNTING MOUNTING PLATE PLATE ADAPTER ADAPTER 6.20 [157.5] 11 3.54 [90.0] RAIL MOUNT MOUNT PTC2 HEATER HEATER DINDINRAIL 22 1030-1342-001 1030-1342-001 NOTES: B, C, D, H, J, K, L & M SYSTEM TYPES 1. "TEMPERATURE ACTIVATED" - PTC HEATERS ARE CONTROLLED BY AN INTERNAL THERMOSTAT, 300 WATT, W/FAN 300 300 WATT, WATT, W/FAN W/FAN FORCED CONVECTION FORCED FORCED CONVECTION CONVECTION NOTE: NOTE: Units Units A,AT A, E,DIN E, F& FRAIL & GG areare dual dual rated rated forfor 120V–220V 120V–220V (use (use 0 for 0 for voltage voltage selection). selection). SET TO ENERGIZE 5°C±3°C MOUNTING: C CC 2. HI-RECOVERY PTC HEATERS OPERATE AS A STANDARD 200 0R 300 WATT PTC HEATER WITH A HI-RECOVERY 400W Shipping Shipping weight: weight: 1 1lb.MODE lb. ACTIVATED BY AN INTEGRAL THERMOSTAT, SET TO ENERGIZE AT 5°C±3°C. 400 WATT, W/FAN 400 400 WATT, WATT, W/FAN W/FAN FORCED CONVECTION FORCED FORCED CONVECTION CONVECTION 3. UNITS "A, E, F & G ARE DUAL RATED FOR 120V-220V SERVICE. USE "0" FOR DUAL VOLTAGE SELECTION. D DD 2.24 [56.8] 120VAC - 240VAC ELECTRICAL CONNECTIONS 2.37 [60.1] HARNESS 200 WATT, W/FAN 200 200 WATT, WATT, W/FAN W/FAN TEMPERATURE ACTIVATED TEMPERATURE TEMPERATURE ACTIVATED ACTIVATED H HH 2.762.76 1.391.39 12.0' [3.66M] DIN 1.391.39 RAIL MOUNT 300 WATT, W/FAN 300 300 WATT, WATT, W/FAN W/FAN TEMPERATURE ACTIVATED TEMPERATURE TEMPERATURE ACTIVATED ACTIVATED J JJ 400 WATT, W/FAN 400 400 WATT, WATT, W/FAN W/FAN TEMPERATURE ACTIVATED TEMPERATURE TEMPERATURE ACTIVATED ACTIVATED KKK PTC2 HEATER E & F SYSTEM TYPES DINDIN 1.39 RAIL RAIL [35.3] MOUNT MOUNT BLACK (LINE) 6.50 [165.16] 6.206.20 3.78 [96.02] 3.843.84 L LL MOUNTING: DIN RAIL WHITE (NEUTRAL) DINDIN RAILRAIL MOUNT MOUNT 200/400 WATT, W/FAN 200/400 200/400 WATT, WATT, W/FAN W/FAN 200W FAN 200W 200W & FAN && FAN 400 WATT HI-RECOVERY 400 400 WATT WATT HI-RECOVERY HI-RECOVERY TEMPERATURE ACTIVATED TEMPERATURE TEMPERATURE ACTIVATED ACTIVATED 144.00 144.00 DIN RAIL 2.782.78 MOUNT 3.84 3.54 3.54 [97.5] 2.36 [60.0] 2.362.36 2.78 [70.64] 300/400 WATT, W/FAN 300/400 300/400 WATT, WATT, W/FAN W/FAN 300W & FAN FAN 300W 300W & FAN & 400 WATT HI-RECOVERY 400 400 WATT WATT HI-RECOVERY HI-RECOVERY TEMPERATURE ACTIVATED TEMPERATURE TEMPERATURE ACTIVATED ACTIVATED M MM 2.76 [70.12] 2.242.24 2.242.24 INCHES / [MM] 2.372.37 2.24 [56.8] 120VAC - 240VAC ELECTRICAL 2.372.37 CONNECTIONS 2.37 [60.1] HH OO W W TT OO PP I I CC KK YY OO UU RR HH EE AA TT EE RR : : H OW TO PI CK YOU R OWN H EATE R Wattage vs. Heater Inlet Temperature WATTAGE WATTAGE VS. VS. HEATER HEATER INLET INLETTEMPERATURE TEMPERATURE Heater Inlet vs. Outlet Temperature HEATER HEATER INLET INLET VS. VS.OUTLET OUTLETTEMPERATURE TEMPERATURE 500 500 180 180 450 450 160 160 400 400 Outlet Temp Degrees C Outlet Temp Degrees C 140 140 350 350 120 120 300 300 Watts Watts 100 100 250 250 80 80 200 200 60 60 150 150 40 40 100 100 20 20 50 50 0 0 0 0 -10-10 0 0 10 10 20 20 30 30 40 40 50 50 60 60 70 70 Degrees Degrees C C PTC2-B PTC2-B PTC2-C PTC2-C -10-10 0 0 10 10 20 20 30 30 40 40 50 50 60 60 70 70 Inlet Temp Degrees C C Inlet Temp Degrees PTC2-D PTC2-D PTC2-B PTC2-B PTC2-C PTC2-C PTC2-D PTC2-D Contact us for additional information or quotation on Positive Positive Temperature Temperature Coefficient Coefficient (PTC2) (PTC2) heaters heaters areare distributed distributed byby High High Voltage Voltage our extensive range of products and Supply, Supply, a division a division of of Waukesha Waukesha Electric Electric Systems, Systems, Inc. Inc. services: 9011 GOVERNORS ROW | DALLAS, TX 75247-3709 ®® To continually improve its products and services, SPX Transformer Solutions, Inc. reserves the COMPONENTS COMPONENTS TRAINING TRAINING right to change specifications and features without notice. Please contact us for certified dimensions CUSTOM CUSTOM SOLUTIONS SOLUTIONS and drawings. •• To To continually continually improve improve its its products products andand services, services, Waukesha Waukesha Electric Electric Systems Systems reserves reserves thethe right right to to CALL 800-338-5526 change change specifications specifications andand features features without without notice. notice. Please Please contact contact HVS HVS for for certified certified dimensions dimensions andand VISIT www.waukeshacomponents.com drawings. drawings. © 2013 SPX Transformer Solutions, Inc. PTC2-0801 (Rev. 5/14) 3.793.79