5-Year Review of Standards (for the December 2001 RevCom Meeting) AP/A

advertisement
5-Year Review of Standards
(for the December 2001 RevCom Meeting)
AP/A
145-1993 Standard Definitions of Terms for Antennas
{Note: The PAR for P145, originally approved in June 1997, is due to expire at the end of this year. For PAR issues, please contact
Jodi Haasz, NesCom Administrator [j.haasz@ieee.org 732-562-6367].}
Recommendation: Administrative Withdrawal.
149-1979 (R1990) Standard Test Procedures for Antennas
{Note: The PAR for P149, originally approved in March 1997, is due to expire at the end of this year. For PAR issues, please contact Jodi
Haasz, NesCom Administrator [j.haasz@ieee.org 732-562-6367].}
Recommendation: Administrative Withdrawal.
C/DA
1076.2-1996 Standard VHDL Language Math Packages
Sponsor states that a reaffirmation is in progress and requests an extension.
Recommendation: Extend until December 2002.
C/LM
802.4-1990 (R1995) Standard for Token-Passing Bus Access Method and Physical Layer Specifications
{Also 802.4h-1997 Standard Local and Metropolitan Area Networks: Alternative Use of BNC Connectors and
Manchester-Encoded Signaling Methods for Single-Channel Bus Physical Layer Entities}
Recommendation: Administrative Withdrawal.
C/MM
896.5-1993 Standard for Futurebus+®, Profile M (Military)
{Also, 896.5a-1994 Standard for Futurebus+®, Profile M (Military): Errata, Corrections, and Clarifications}
Sponsor wishes to proceed with administrative withdrawal.
Recommendation: Administrative Withdrawal.
1101.10-1996 Standard for Additional Mechanical Specifications for Micorcomputers Using the IEEE 1101.11991 Equipment Practice
Sponsor states that a reaffirmation is in progress and requests an extension.
Recommendation: Extend until December 2002.
1156.1-1993 Standard for Microcomputer Environmental Specifications for Computer Modules
Sponsor is investigating the actions to take on this standard and requests an extension.
Recommendation: Extend until December 2002.
1156.2-1996 Standard for Environmental Specifications for Computer Systems
Sponsor is investigating the actions to take on this standard and requests an extension.
Recommendation: Extend until December 2002.
RevCom, December 2001
1296-1987 (R1994) Standard for a High-Performance Synchronous 32-Bit Bus: MULTIBUS II
Sponsor wishes to proceed with administrative withdrawal.
Recommendation: Administrative Withdrawal.
1301.4-1996 Standard for a Metric Equipment Practice for Microcomputers - Coordination Document for
Mezzanine Cards
Sponsor states that a reaffirmation is in progress and requests an extension.
Recommendation: Extend until December 2002.
1596.3-1996 Standard for Low-Voltage Differential Signals (LVDS) for Scalable Coherent Interface (SCI)
Sponsor wishes to proceed with administrative withdrawal.
Recommendation: Administrative Withdrawal.
1596.4-1996 Standard for High-Bandwidth Memory Interface Based on Scalable Coherent Interface (SCI)
Signaling Technology (RamLink)
Sponsor wishes to proceed with administrative withdrawal.
Recommendation: Administrative Withdrawal.
C/PA
1003.0-1995 Guide to the POSIX Open System Environment (OSE)
Recommendation: Administrative Withdrawal.
1387.3-1996 (POSIX) System Administration - Part 3: User and Group Account Administration
Recommendation: Administrative Withdrawal.
2003.2-1996 Standard for Information Technology - Test Methods for Measuring Conformance to POSIX - Part II:
Shell and Utilities
Sponsor states that a reaffirmation is in progress and requests an extension. {voicemail message from Lowell
Johnson on 27-Sep-01}
Recommendation: Extend until December 2002.
C/SE
610.12-1990 Standard Glossary of Software Engineering Terminology
Sponsor states that a reaffirmation is in progress and requests an extension.
Recommendation: Extend until December 2002.
982.2-1988 Guide for the Use of IEEE Standard Dictionary of Measures to Produce Reliable Software
Sponsor wishes to proceed with administrative withdrawal.
Recommendation: Administrative Withdrawal.
1008-1987 (R1993) Standard for Software Unit Testing
Sponsor states that a reaffirmation is in progress and requests an extension.
Recommendation: Extend until December 2002.
1044-1993 Standard Classification for Software Anomalies
Sponsor states that a reaffirmation is in progress and requests an extension.
RevCom, December 2001
Recommendation: Extend until December 2002.
1045-1992 Standard for Software Productivity Metrics
Sponsor states that a reaffirmation is in progress and requests an extension.
Recommendation: Extend until December 2002.
1062-1993 Recommended Practice for Software Acquisition
{Also, 1062a-1998 Recommended Practice for Software Acquisition (Amendment)}
Sponsor states that a reaffirmation is in progress and requests an extension.
Recommendation: Extend until December 2002.
1175-1991 Standard Reference Model for Computing System Tool Interconnections
Sponsor wishes to proceed with administrative withdrawal.
Recommendation: Administrative Withdrawal.
1233-1996 Guide for Developing System Requirements Specifications
{Also, 1233a-1998 Guide for Developing System Requirements Specifications (Amendment)}
Sponsor states that a reaffirmation is in progress and requests an extension.
Recommendation: Extend until December 2002.
1420.1-1995 Standard for Information Technology - Software Reuse - Data Model for Reuse Library
Interoperability: Basic Interoperability Data Model (BIDM)
{Also, 1420.1a-1996 Supplement to Standard for Information Technology - Software Reuse - Data Model for
Reuse Library Interoperability: Asset Certifcation Framework [Developed in cooperation with the Reuse
Library Interoperability Group (RIG)] and 1420.1b-1999 Standard for Information Technology - Software
Reuse - Data Model for Reuse Library Interoperability: Intellectual Property Rights Framework}
Sponsor states that a reaffirmation is in progress and requests an extension.
Recommendation: Extend until December 2002.
1430-1996 Guide for Information Technology - Software Reuse - Concept of Operations for Interoperating Reuse
Libraries [Developed in cooperation with the Reuse Library Interoperability Group (RIG)]
Sponsor wishes to proceed with administrative withdrawal.
Recommendation: Administrative Withdrawal.
C/SISC
1278.3-1996 Recommended Practice for Distributed Interactive Simulation - Exercise Management and Feedback
Sponsor states that a reaffirmation is in progress and requests an extension.
Recommendation: Extend until December 2002.
C/TT
662-1992 Standard Terminology for Semiconductor Memory
{Note: The PAR for P662, originally approved in September 1997, is due to expire at the end of this year. For actions on PARs,
please contact Jodi Haasz, NesCom Administrator [j.haasz@ieee.org 732-562-6367].}
Recommendation: Administrative Withdrawal.
1149.5-1995 Standard for Module Test and Maintenance Bus (MTM-Bus) Protocol
Sponsor states that a reaffirmation is in progress.
RevCom, December 2001
Recommendation: Extend until December 2002.
COM/TA&OS
167A.2-1996 Standard Facsimile Test Chart: High Contrast (Gray Scale)
Sponsor states that a group is being formed to ballot a reaffirmation and requests an extension.
Recommendation: Extend until December 2003.
167A.3-1997 Standard Facsimile Test Chart - Color
Sponsor states that a group is being formed to ballot a reaffirmation and requests an extension.
Recommendation: Extend until December 2003.
367-1996 Recommended Practice for Determining the Electric Power Station Ground Potential Rise and
Induced Voltage from a Power Fault
{Jointly sponsored with PE/PSC}
Recommendation: Administrative Withdrawal.
1027-1996 Standard Method for Measurement of the Magnetic Field in the Vicinity of a Telephone Receiver
Recommendation: Administrative Withdrawal.
DEI
101-1987 (R1995) (DEI) Guide for the Statistical Analysis of Thermal Life Test Data
Sponsor states that a reaffirmation is in progress and requests a two-year extension.
Recommendation: Extend until December 2003.
DEI/VE
1043-1996 (DEI/VE) Recommended Practice for Voltage-Endurance Testing of Form-Wound Bars and Coils
Sponsor states that a reaffirmation is in progress and requests a two-year extension.
Recommendation: Extend until December 2003.
EMB
1417-1996 (EMB) ANSI/AAMI EC13-1992 - Cardiac Monitors, Heart Rate Meters, and Alarms
Recommendation: Administrative Withdrawal.
1426-1996 (EMB) ANSI/AAMI EC11-1991 - Diagnostic Electrocardiographic Devices
Recommendation: Administrative Withdrawal.
EMC/SC
140-1990 (R1995) Recommended Practice for Minimization of Interference from Radio-Frequency Heating
Equipment
Recommendation: Administrative Withdrawal.
RevCom, December 2001
1309-1996 Standard for Calibration of Electromagnetic Field Sensors and Probes, Excluding Antennas, from 9 kHz to
40 GHz
Recommendation: Administrative Withdrawal.
IA/IA&C
518-1982 (R1996) Guide for the Installation of Electrical Equipment to Minimize Electrical Noise Inputs to Controllers
from External Sources
Recommendation: Administrative Withdrawal.
IA/IPC
519-1992 Recommended Practices and Requirements for Harmonic Control in Electrical Power Systems
{Note: The PAR for P519, originally approved September 1997, is due to expire at the end of this year. For actions on PARs, please contact
Jodi Haasz, NesCom Administrator [j.haasz@ieee.org 732-562-6367].}
Sponsor has submitted a PAR extension request to NesCom.
Recommendation: Extend until the expiration of the PAR for P519.
IA/PCI
1068-1996 Recommended Practice for the Repair and Rewinding of Motors for the Petroleum and Chemical Industry
Sponsor states that a working group has been formed to formulate and submit a PAR for revision.
Recommendation: Extend until December 2002.
PE/ED&PG
125-1988 (R1996) Recommended Practice for Preparation of Equipment Specifications for Speed-Governing of
Hydraulic Turbines Intended to Drive Electric Generators
Sponsor has submitted a PAR for revision to NesCom.
Recommendation: Extend until the expiration of the PAR for P125.
421.5-1992 Recommended Practice for Excitation System Models for Power System Stability Studies
{Note: The PAR for P421.5, originally approved December 1997, is due to expire at the end of this year. For actions on PARs, please
contact Jodi Haasz, NesCom Administrator [j.haasz@ieee.org 732-562-6367].}
Sponsor has submitted a PAR extension request to NesCom.
Recommendation: Extend until the expiration of the PAR for P421.5.
690-1984 (R1996) Standard for the Design and Installation of Cable Systems for Class 1E Circuits in Nuclear
Power Generating Stations
Sponsor states that a reaffirmation is in progress and requests an extension.
Recommendation: Extend until December 2002.
944-1986 (R1996) Recommended Practice for the Application and Testing of Uninterruptible Power Supplies
for Power Generating Stations
Sponsor has submitted a PAR for revision to NesCom.
Recommendation: Extend until the expiration of the PAR for P944.
RevCom, December 2001
1020-1988 (R1994) Guide for Control of Small Hydroelectric Power Plants
Sponsor states that a reaffirmation is in progress and requests an extension.
Recommendation: Extend until December 2002.
1046-1991 (R1996) Application Guide for Distributed Digital Control and Monitoring for Power Plants
Sponsor states that a working group has been formed to review the standard's validity and requests an
extension.
Recommendation: Extend until December 2002.
1069-1991 (R1996) Recommended Practice for Precipitator and Baghouse Hopper Heating Systems
Sponsor states that a reaffirmation is in progress and requests an extension.
Recommendation: Extend until December 2002.
1249-1996 Guide for Computer-Based Control of Hydroelectric Power Plant Automation
Sponsor has submitted a PAR for revision to NesCom.
Recommendation: Extend until the expiration of the PAR for P1249.
PE/EM
67-1990 (R1995) Guide for Operation and Maintenance of Turbine Generators
Sponsor states that a working group will be formed to review the standard's validity and requests an extension.
Recommendation: Extend until December 2002.
95-1977 (R1991) Recommended Practice for Insulation Testing of Large AC Rotating Machinery with High
Direct Voltage
{Note: The PAR for P95, originally approved March 1997, is due to expire at the end of this year. For actions on PARs, please
contact Jodi Haasz, NesCom Administrator [j.haasz@ieee.org 732-562-6367].}
Sponsor has submitted a PAR extension request to NesCom.
Recommendation: Extend until the expiration of the PAR for P95.
115-1995 Guide: Test Procedures for Synchronous Machines Part I: Acceptance and Performance Testing; Part
II: Test Procedures and Parameter Determination for Dynamic Analysis
Sponsor states that a reaffirmation is in progress and requests an extension.
Recommendation: Extend until December 2002.
792-1995 Recommended Practice for the Evaluation of the Impulse Voltage Capability of Insulation Systems
for AC Electric Machinery Employing Form-Wound Stator Coils
Sponsor wishes to proceed with administrative withdrawal.
Recommendation: Administrative Withdrawal.
1107-1996 Recommended Practice for Thermal Evaluation of Sealed Insulation Systems for AC Electric
Machinery Employing Random-Wound Stator Coils
Sponsor states that a reaffirmation is in progress and requests an extension.
Recommendation: Extend until December 2002.
1310-1996 Trial Use Recommended Practice for Thermal Cycle Testing of Form-Wound Stator Bars and Coils
for Large Generators
{Note: This document can be revised as normal. However, it cannot be reaffirmed. Trial-use documents are supposed to be valid for two
years}
Sponsor has requested elevation to full use status and requests a two-year extension to allow time to reaffirm.
RevCom, December 2001
Recommendation: Extend until December 2003.
PE/IC
48-1996 Standard Test Procedures and Requirements for Alternating-Current Cable Terminations 2.5 kV
through 765 kV
Sponsor states that a working group has been formed to review the standard's validity and requests an
extension.
Recommendation: Extend until December 2002.
442-1981 (R1996) Guide for Soil Thermal Resistivity Measurements
Sponsor states that a working group has been formed to review the standard's validity and requests an
extension.
Recommendation: Extend until December 2002.
582-1990 (R1996) Standard for Exposed Semiconducting Shields on High-Voltage Cable Joints and Separable
Insulated Connectors
Sponsor states that a working group has been formed to review the standard's validity and requests an
extension.
Recommendation: Extend until December 2002.
848-1996 Standard Procedure for the Determination of the Ampacity Derating of Fire-Protected Cables
Sponsor states that a working group has been formed to review the standard's validity and requests an
extension.
Recommendation: Extend until December 2002.
1210-1996 Standard Tests for Determining Compatibility of Cable-Pulling Lubricants with Wire and Cable
Sponsor states that a working group has been formed to review the standard's validity and requests an
extension.
Recommendation: Extend until December 2002.
1299-1996/C62.22.1 Guide for the Connection of Surge Arrestors to Protect Insulated, Shielded Electric Power
Cable Systems
Sponsor states that a working group has been formed to review the standard's validity and requests an
extension.
Recommendation: Extend until December 2002.
1300-1996 Guide for Cable Connections for Gas-Insulated Substations
Sponsor states that a reaffirmation is in progress and requests an extension.
Recommendation: Extend until December 2002.
PE/NPE
7-4.3.2-1993 Standard Criteria for Digital Computers in Safety Systems of Nuclear Power Generating Stations
Recommendation: Administrative Withdrawal.
317-1983 (R1996) Standard for Electric Penetration Assemblies in Containment Structures for Nuclear Power
Generating Stations
Recommendation: Administrative Withdrawal.
RevCom, December 2001
323-1983 (R1996) Standard for Qualifying Class 1E Equipment for Nuclear Power Generating Stations
{Note: The PAR for P323, originally approved March 1997, is due to expire at the end of this year. For actions on PARs, please
contact Jodi Haasz, NesCom Administrator [j.haasz@ieee.org 732-562-6367].}
Sponsor has submitted a PAR extension request to NesCom.
Recommendation: Extend until the expiration of the PAR for P323.
336-1985 (R1991) Standard Installation, Inspection, and Testing Requirements for Power, Instrumentation, and
Control Equipment at Nuclear Facilities
Recommendation: Administrative Withdrawal.
382-1996 Standard for Qualification of Actuators for Power-Operated Valve Assemblies with Safety-Related
Functions for Nuclear Power Plants
Recommendation: Administrative Withdrawal.
572-1985 (R1992) Standard for Qualification of Class 1E Connection Assemblies for Nuclear Power
Generating Stations
Recommendation: Administrative Withdrawal.
627-1980 (R1996) Standard for Design Qualification of Safety Systems Equipment Used in Nuclear Power
Generating Stations
Recommendation: Administrative Withdrawal.
PE/PSC
367-1996 Recommended Practice for Determining the Electric Power Station Grounding Potential Rise and
Induced Voltage from a Power Fault
{Jointly sponsored with COM/TA&OS}
Recommendation: Administrative Withdrawal.
1138-1994 Standard Construction of Composite Fiber Optic Groundwire (OPGW) for Use on Electric Utility
Power Lines
Recommendation: Administrative Withdrawal.
PE/PSIM
4-1995 Standard Techniques for High-Voltage Testing
{Also, 4a-2001 Amendment to High Voltage Test Techniques}
Sponsor has submitted a PAR for revision to NesCom.
Recommendation: Extend until the expiration of the PAR for P4 [December 2005], which was approved via continuous
processing.
PE/PSR
C37.90-1989 (R1994) Standard for Relays and Relay Systems Associated with Electric Power Apparatus
{Note: The PAR for PC37.90, originally approved June 1991, is due to expire at the end of this year. For actions on PARs, please contact Jodi
Haasz, NesCom Administrator [j.haasz@ieee.org 732-562-6367].}
Sponsor has submitted a PAR extension request to NesCom.
RevCom, December 2001
Recommendation: Extend until the expiration of the PAR for PC37.90.
PE/SPD
1313.1-1996 Standard for Insulation Coordination - Definitions, Principles, and Rules
[PE/TC ?]
Sponsor states that a reaffirmation is in progress and requests an extension.
Recommendation: Extend until December 2002.
C62.37-1996 Standard Test Specification for Thyristor Diode Surge Protection Devices
Recommendation: Administrative Withdrawal.
C62.92.4-1991 (R1996) Guide for the Application of Neutral Grounding in Electrical Utility Systems, Part IV Distribution
Sponsor states that a reaffirmation is in progress and requests an extension.
Recommendation: Extend until December 2002.
PE/SUB
857-1996 Recommended Practice for Test Procedures for High-Voltage Direct-Current Thyristor Valves
Sponsor states that a reaffirmation is in progress.
Recommendation: Extend until December 2002.
998-1996 Guide for Direct Lightning Stroke Shielding of Substations
Sponsor states that a reaffirmation is in progress.
Recommendation: Extend until December 2002.
1158-1991 (R1996) Recommended Practice for Determination of Power Losses in High-Voltage Direct-Current
(HVDC) Converter Stations
Sponsor wishes to proceed with administrative withdrawal.
Recommendation: Administrative Withdrawal.
C37.122-1993 Standard for Gas-Insulated Substations
{Note: The PAR for PC37.122, originally approved December 1997, is due to expire at the end of this year. For actions on PARs,
please contact Jodi Haasz, NesCom Administrator [j.haasz@ieee.org 732-562-6367].}
Sponsor states that a reaffirmation is in progress.
Recommendation: Extend until December 2002.
C37.123-1996 Guide to Specifications for Gas-Insulated, Electric Power Substation Equipment
Sponsor states that a reaffirmation is in progress.
Recommendation: Extend until December 2002.
PE/SWG
1325-1996 Recommended Practice for Reporting Field Failure Data for Power Circuit Breakers
Recommendation: Administrative Withdrawal.
RevCom, December 2001
C37.011-1994 Application Guide for Transient Recovery Voltage for AC High-Voltage Circuit Breakers Rated
on a Symmetrical Current Basis
Sponsor has submitted a PAR for revision to NesCom.
Recommendation: Extend until the expiration of the PAR for PC37.011.
C37.081-1981 (R1988) Guide for Synthetic Fault Testing of AC High-Voltage Circuit Breakers Rated on a
Symmetrical Current Basis
{Also C37.081a-1997 Supplement to Guide for Synthetic Fault Testing of AC High-Voltage Circuit Breakers
Rated on a Symmetrical Current Basis}
Recommendation: Administrative Withdrawal.
C37.10-1995 Guide for Diagnostics and Failure Investigation of Power Circuit Breakers
Recommendation: Administrative Withdrawal.
C37.13-1990 (R1995) Standard for Low-Voltage AC Power Circuit Breakers Used in Enclosures
Recommendation: Administrative Withdrawal.
C37.18-1979 (R1996) Standard Enclosed Field Discharge Circuit Breakers for Rotating Electric Machinery
Recommendation: Administrative Withdrawal.
C37.26-1972 (R1996) Standard Guide for Methods of Power-Factor Measurement for Low-Voltage Inductive
Test Circuits
Recommendation: Administrative Withdrawal.
C37.34-1994 Standard Test Code for High-Voltage Air Switches
Recommendation: Administrative Withdrawal.
C37.35-1995 Guide for the Application, Installation, Operation, and Maintenance of High-Voltage Air
Disconnecting and Interrupter Switches
Recommendation: Administrative Withdrawal.
C37.36b-1990 (R1996) Guide to Current Interruption with Horn-Gap Air Switches
Recommendation: Administrative Withdrawal.
C37.37-1996 Loading Guide for AC High-Voltage Air Switches (in Excess of 1000 V)
Recommendation: Administrative Withdrawal.
C37.38-1989 Standard for Gas Insulated, Metal-Enclosed Disconnecting, Interrupter, and Grounding Switches
Recommendation: Administrative Withdrawal.
PE/T&D
539-1990 Standard Definitions of Terms Relating to Corona and Field Effects of Overhead Power Lines
{Note: The PAR for P539, originally approved June 1995, is due to expire at the end of this year. For actions on PARs, please contact
Jodi Haasz, NesCom Administrator [j.haasz@ieee.org 732-562-6367].}
Sponsor has submitted a PAR extension request to NesCom.
Recommendation: Extend until the expiration of the PAR for P539.
563-1978 (R1996) Guide on Conductor Self-Damping Measurements
Sponsor states that a reaffirmation is in progress and requests an extension.
RevCom, December 2001
Recommendation: Extend until December 2002.
951-1996 Guide to the Assembly and Erection of Metal Transmission Structures
Sponsor states that a reaffirmation will be initiated and requests an extension.
Recommendation: Extend until December 2002.
1260-1996 Guide on the Prediction, Measurement, and Analysis of AM Broadcast Reradiation by Power Lines
Sponsor states that a reaffirmation will be initiated and requests an extension.
Recommendation: Extend until December 2002.
PE/TC
1313.1-1996 Standard for Insulation Coordination - Definitions, Principles, and Rules
[PE/SPD now?]
Sponsor states that a reaffirmation is in progress and requests an extension.
Recommendation: Extend until December 2002.
PE/TR
637-1985 Guide for the Reclamation of Insulating Oil and Criteria for Its Use
Sponsor states that a reaffirmation is in progress and requests a two-year extension.
Recommendation: Extend until December 2003.
C57.12.20-1996 Standard for Overhead Type Distribution Transformers, 500 kVA and Smaller, High-Voltage
34 500 Volts and Below; Low-Voltage, 7970/13 800Y Volts and Below
Sponsor has submitted a PAR for revision to NesCom.
Recommendation: Extend until the expiration of the PAR for PC57.12.20.
C57.12.35-1996 Standard for Bar Coding for Distribution Transformers
Sponsor states that a reaffirmation is in progress and requests a two-year extension.
Recommendation: Extend until December 2003.
C57.12.40-1993 Standard for Requirements for Secondary Network Transformers - Subway and Vault Types
(Liquid Immersed)
Sponsor has submitted a PAR for revision to NesCom.
Recommendation: Extend until the expiration of the PAR for PC57.12.40.
C57.12.58-1991 (R1996) Guide for Conducting a Transient Voltage Analysis of a Dry Type Transfomer Coil
Sponsor states that a reaffirmation is in progress and requests a two-year extension.
Recommendation: Extend until December 2003.
C57.19.03-1996 Standard Requirements, Terminology, and Test Code for Bushings for DC Applications
Sponsor states that a reaffirmation is in progress and requests a two-year extension.
Recommendation: Extend until December 2003.
C57.19.100-1995 Guide for Application of Power Apparatus Bushings
Sponsor states that a reaffirmation is in progress and requests an extension.
Recommendation: Extend until December 2002.
RevCom, December 2001
C57.21-1990 (R1995) Standard Requirements, Terminology, and Test Code for Shunt Reactors Rated Over 500
kVA
Sponsor states that a reaffirmation is in progress and requests a two-year extension.
Recommendation: Extend until December 2003.
C57.91-1995 Guide for Loading Mineral-Oil-Immersed Transformers
Sponsor states that a reaffirmation is in progress and requests an extension.
Recommendation: Extend until December 2002.
C57.111-1989 (R1995) Guide for Acceptance of Silicone Insulating Fluid and Its Maintenance in Transformers
Sponsor states that a reaffirmation is in progress and requests a two-year extension.
Recommendation: Extend until December 2003.
C57.124-1991 (R1996) Recommended Practice for the Detection of Partial Discharge and the Measurement of
Apparent Charge in Dry Type Transformers
Sponsor states that a reaffirmation is in progress and requests a two-year extension.
Recommendation: Extend until December 2003.
C57.131-1995 Standard Requirements for Load Tap Changers
Sponsor states that a reaffirmation is in progress and requests a two-year extension.
Recommendation: Extend until December 2003.
PEL/ET
389-1996 Recommended Practice for Testing Electronics Transformers and Inductors
Sponsor states that a group is being formed to ballot a reaffirmation and requests an extension.
Recommendation: Extend until December 2003.
SCC14
260.4-1996 American National Standard Letter Symbols and Abbreviations for Quantities Used in Acoustics
Sponsor states that a reaffirmation is in progress.
Recommendation: Extend until December 2002.
SCC20
1226.6-1996 ABBET Guide for the Understanding of the "A Broad Based Environment for Test (ABBET)"
Standard
Sponsor wishes to proceed with administrative withdrawal.
Recommendation: Administrative Withdrawal.
SCC21
1144-1996 Recommended Practice for Sizing Nickel-Cadmium Batteries for Photovoltaic (PV) Systems
Sponsor wishes to proceed with administrative withdrawal.
Recommendation: Administrative Withdrawal.
RevCom, December 2001
1262-1995 Recommended Practice for Qualificaton of Photovoltaic (PV) Modules
Recommendation: Administrative Withdrawal.
SCC28
1460-1996 Guide for the Measurement of Quasi-Static Magnetic and Electric Fields
Sponsor states that a reaffirmation is in progress and requests an extension.
Recommendation: Extend until December 2002.
SCC29
450-1995 Recommended Practice for Maintenance, Testing, and Replacement of Vented Lead-Acid Batteries
for Stationary Applications
{Note: The PAR for P450, originally approved December 1995, is due to expire at the end of this year. For actions on PARs, please
contact Jodi Haasz, NesCom Administrator [j.haasz@ieee.org 732-562-6367].}
Sponsor has submitted a PAR extension request to NesCom.
Recommendation: Extend until the expiration of the PAR for P450.
1189-1996 Guide for Selection of Valve-Regulated Lead-Acid (VRLA) Batteries for Stationary Applications
Sponsor has submitted a PAR for revision to NesCom.
Recommendation: Extend until the expiration of the PAR for P1189.
UFFC
790-1989 (R1996) Guide for Medical Ultrasound Field Parameter Measurements
Sponsor wishes to proceed with administrative withdrawal.
Recommendation: Administrative Withdrawal.
RevCom, December 2001
Download