Meeting: GLAST Preliminary Design Review, January 8-11, 2002 Subsystem: Electrical RFA Number: 51 Originator: Fred Huegel, Code 561, 301-286-2286 Response Accepted/ RFA Closed: _________________ (Originator’s initials) Specific Request: Ensure that flight tantalum caps receive 100% surge current testing and conservative derating to provide for maximum protection against short circuit failures in the tracker electronics. Supporting Rational: A large number of tantalum capacitors are used in the tracker electronics. A short in any of them can bring down an entire tracker stack. Response: Conservative derating has been adopted and we expect to procure only tantalum caps which have been surge current tested. If we are unable to procure sufficient number of tested parts, then we will complete the testing ourselves in accordance with MIL-PRF-55365.