REQUEST FOR QUOTATIONS TITLE: PURCHASE OF TWO ONLY 7000 L.P.M. TRIPLE COMBINATION

advertisement
REQUEST FOR QUOTATIONS
TITLE:
PURCHASE OF TWO ONLY
7000 L.P.M. TRIPLE COMBINATION
PUMPER UNITS
REFERENCE No.: 1220-41-25-09
FOR THE SUPPLY OF GOODS
V. October 07, 2009
REQUEST FOR QUOTATIONS
TABLE OF CONTENTS
1. INTRODUCTION........................................................................................................... 01
2. ADDRESS FOR DELIVERY .......................................................................................... 01
3. DATE ............................................................................................................................ 01
4. INQUIRIES .................................................................................................................... 01
5. ADDENDA .................................................................................................................... 01
6. DURATION OF QUOTATION ....................................................................................... 02
7. NO CONTRACT ............................................................................................................ 02
8. ACCEPTANCE.............................................................................................................. 02
9. CONTRACTOR’S EXPENSES ...................................................................................... 02
10. CONTRACTOR’S QUALIFICATIONS ........................................................................... 02
11. CONFLICT OF INTEREST ............................................................................................ 02
12. SOLICITATION OF COUNCIL MEMBERS AND CITY STAFF ...................................... 02
13. CONFIDENTIALITY ...................................................................................................... 03
14. SIGNATURE ................................................................................................................. 03
15. GOODS AND SERVICES TAX AND CUSTOMS DUTY ................................................ 03
SCHEDULE A – SPECIFICATIONS OF GOODS AND SCOPE OF SERVICES ................. 04
Part I – General Specifications & Requirements ............................................................ 05
Part II – Technical Specifications & Requirements ........................................................ 24
SCHEDULE B – GENERAL TERMS AND CONDITIONS ................................................... 87
SCHEDULE C – FORM OF QUOTATION........................................................................... 94
ii
REQUEST FOR QUOTATIONS
1.
INTRODUCTION
The City of Surrey (the “City”) invites contractors to provide a quotation on the form
attached as Schedule C (the "Quotation") for the supply of the goods (if any) and
services described in Schedule A (the "Goods and Services"). The description of the
Goods and Services sets out the minimum requirements of the City. A person that
submits a Quotation (the "Contractor") should prepare a Quotation that meets the
minimum requirements, and may choose, in addition, to also include goods, services or
terms that exceed the minimum requirements.
2.
ADDRESS FOR DELIVERY
The Quotation should be submitted to the City at the office of:
Manager, Purchasing & Payments
City of Surrey - Purchasing Section
6645 – 148th Street
Surrey, British Columbia V3S 3C7 CANADA
Contractors should submit the original plus two (2) electronic copies in PDF format on
CDs (three (3) in total) of their Quotation. The original Quotation should be unbound.
3.
DATE
The City would prefer to receive Quotations on or before Friday, November 20, 2009.
The City's office hours are 8:30 a.m. to 4:00 p.m., Monday to Friday, except statutory
holidays.
4.
INQUIRIES
All inquiries related to this Request for Quotation ("RFQ") should be directed in writing
to:
Manager, Purchasing & Payments
City of Surrey - Purchasing Section
6645 – 148th Street
Surrey, British Columbia V3S 3C7 CANADA
Fax No.: 604-599-0956
Tel: 604-590-7274
Email: purchasing@surrey.ca
5.
ADDENDA
If the City determines that an amendment is required to this RFQ, the City will post a
written addendum on the City website at www.surrey.ca (the "City Website") and upon
posting will be deemed to form part of this RFQ. Upon submitting a Quotation,
Contractors will be deemed to have received notice of all addenda that are posted on the
City Website.
RFQ (Goods and Services) No.: 1220-41-25-09
1
6.
DURATION OF QUOTATION
The Quotation will be open for acceptance by the City until:
(a)
(b)
7.
the date specified in this RFQ or in a Quotation; or
as described in a subsequent written notice which the Contractor may send to the
City.
NO CONTRACT
This RFQ is simply an invitation for quotations (including prices and terms) for the
convenience of all parties. It is not a tender and no obligations of any kind will arise from
this RFQ or the submission of Quotations. The City may negotiate changes to any terms
of a Quotation, including terms in Schedules A and B and including prices, and may
negotiate with one or more Contractors or may at any time invite or permit the submission
of quotations (including prices and terms) from other parties who have not submitted
Quotations.
8.
ACCEPTANCE
A Quotation will be an offer to the City which, subject to Section 6, the City may accept
at any time by signing the copy of the Quotation and delivering it to the Contractor. A
Quotation is not accepted by the City unless and until both the Authorized Signatory and
the Purchasing Representative have signed on behalf of the City. Delivery of the signed
Quotation by the City may be by fax. In that event, the contract will be comprised of the
documents included in the definition of Agreement in Schedule B – General Terms and
Conditions.
9.
CONTRACTOR'S EXPENSES
Contractors are solely responsible for their own expenses in preparing and submitting
Quotations, and for any meetings, negotiations or discussions with the City or its
representatives and contractors, relating to or arising from the RFQ. The City will not be
liable to any Contractor for any claims, whether for costs, expenses, losses or damages,
or loss of anticipated profits, incurred by the Contractor in preparing and submitting a
Quotation, or participating in negotiations for a contract, or other activity related to or
arising out of this RFQ.
10.
CONTRACTOR'S QUALIFICATIONS
By submitting a Quotation, a Contractor represents that it has the expertise,
qualifications, resources, and relevant experience to supply the Goods and Services.
11.
CONFLICT OF INTEREST
A Contractor must disclose in its Quotation any actual or potential conflicts of interest
and existing business relationships it may have with the City, its elected or appointed
officials or employees. The City may rely on such disclosure.
12.
SOLICITATION OF COUNCIL MEMBERS AND CITY STAFF
Contractors and their agents will not contact any member of the City Council or City staff
with respect to this RFQ, other than the contact person named in Section 2, at any time
prior to the award of a contract or the cancellation of this RFQ.
RFQ (Goods and Services) No.: 1220-41-25-09
2
13.
CONFIDENTIALITY
All Quotations become the property of the City and will not be returned to the Contractor.
All Quotations will be held in confidence by the City unless otherwise required by law.
Contractors should be aware the City is a "public body" defined by and subject to the
Freedom of Information and Protection of Privacy Act of British Columbia.
14.
SIGNATURE
The legal name of the person or firm submitting the Quotation should be inserted in the
Quotation. The Quotation should be signed by a person authorized to sign on behalf of
the Contractor and include the following:
15.
(a)
If the Contractor is a corporation then the full name of the corporation should be
included, together with the names of authorized signatories. The Quotation
should be executed by all of the authorized signatories or by one or more of them
provided that a copy of the corporate resolution authorizing those persons to
execute the Quotation on behalf of the corporation is submitted;
(b)
If the Contractor is a partnership or joint venture then the name of the partnership
or joint venture and the name of each partner or joint venturer should be
included, and each partner or joint venturer should sign personally (or, if one or
more person(s) have signing authority for the partnership or joint venture, the
partnership or joint venture should provide evidence to the satisfaction of the City
that the person(s) signing have signing authority for the partnership or joint
venture). If a partner or joint venturer is a corporation then such corporation
should sign as indicated in subsection (a) above; or
(c)
If the Contractor is an individual, including a sole proprietorship, the name of the
individual should be included.
GOODS AND SERVICES TAX AND CUSTOMS DUTY
The Contractor agrees that all Canadian G.S.T. and/or Customs, Duty entitlements
provided by the Excise Tax Act and/or Customs/Tariff Acts and Tax or Custom Duty rate
decreases and/or exemptions resulting from amendments, re-classifications, remissions,
or clarifications thereof on tax and/or duty-included goods and materials, whether
recognized or not at the time of award, shall be passed on to the City.
If the Contractor manufactures or purchases any goods with respect to this Agreement,
from outside of Canada, the Contractor must ensure that its agent or representative is
the importer of record, unless otherwise expressly stipulated.
The City shall not be liable for and the Contractor shall indemnify the City with respect to
any special or dumping duties which may be levied by Canada Border Services Agency
(CBSA) and Canada Revenue Agency (CRA), under the provisions of the Anti-Dumping
Act, upon any imported goods required in the supply of materials in any order or in the
performance of this Agreement.
Goods and Services Tax not submitted in accordance with the requested status will be
adjusted accordingly for the purpose of Quotation evaluation. If pricing offered does not
list applied G.S.T. as a separate line item, the City will assume the Contractor has
omitted such tax and the Quotation will be adjusted accordingly to include the
appropriate tax, and the City will consider the Quotation so amended.
RFQ (Goods and Services) No.: 1220-41-25-09
3
SCHEDULE A
SPECIFICATIONS OF GOODS
AND
SCOPE OF SERVICES

PART I – GENERAL SPECIFICATIONS & REQUIREMENTS

PART II – TECHNICAL SPECIFICATIONS & REQUIREMENTS
PURCHASE TWO (2) ONLY 7000 L.P.M. TRIPLE COMBINATION PUMPER UNITS
REFERENCE No.: 1220-41-25-09
RFQ (Goods and Services) No.: 1220-41-25-09
4
PART I – GENERAL SPECIFICATIONS &
REQUIREMENTS
PURCHASE TWO (2) ONLY 7000 L.P.M. TRIPLE COMBINATION PUMPER UNITS
REFERENCE No.: 1220-41-25-09
RFQ (Goods and Services) No.: 1220-41-25-09
5
SCHEDULE A – SPECIFICATIONS OF GOODS AND SCOPE OF SERVICES
PART I - GENERAL SPECIFICATIONS & REQUIREMENTS
1.
GENERAL
The City of Surrey would like to establish a framework agreement to purchase TWO (2) ONLY
of the following 7000 L.P.M. Triple Combination Pumper units (the “Fire Apparatus”) as detailed
in these Specifications & Requirements [Part 1 & Part II].
Each Quotation shall be accompanied by a set of “Contractor’s Specifications” consisting of a
detailed description of the Fire Apparatus and equipment proposed and to which the Fire
Apparatus furnished under contract shall conform. These specifications shall indicate size, type,
model and make of all component parts and equipment.
Yes ____
2.
No ____
INTENT OF SPECIFICATIONS
It shall be the intent of these specifications to cover the furnishing and delivery of a complete
Fire Apparatus equipped as hereinafter specified. These specifications shall cover only the
general requirements as to the type of construction and test to which the Fire apparatus shall
conform, together with certain details as to finish, equipment and appliances with which the
Contractor shall conform. Minor details of construction and materials, which are not otherwise
specified, are left to the discretion of the Contractor, who shall be solely responsible for the
design and construction of all features. The Fire Apparatus must comply with all D.O.T. and
British Columbia Motor Vehicle Act regulations.
All parts for body and chassis which are necessary in order to provide a complete unit, ready for
operation, shall be included in the Quotation and shall conform in strength, quality of
workmanship, and materials to that which is usually provided by the trade in general. Any
variance from these Specifications & Requirements or standards in quality must be clearly
pointed out in writing by the Contractor in their technical Specifications & Requirements.
The Specifications & Requirements for the Fire Apparatus as specified in this Schedule “A”,
describe the minimum specifications & requirements the City would like the Fire Apparatus to
meet. Contractors should prepare a Quotation that meets the minimum specifications, and may,
in addition, also include in a Quotation the supply of a Fire Apparatus that exceeds the minimum
Specifications & Requirements.
The Contractor will coordinate progress of the Services, progress schedules, and submittals.
The unit(s) proposed shall be new, manufacturer’s latest make and model in current production
as offered to commercial trade and shall be furnished complete with all factory-installed
standard equipment and accessories listed in the manufacturer’s latest literature for the
respective unit and any additional equipment as may be defined in the technical specifications.
Throughout these Specifications & Requirements, compatibility is of the essence and any
modification, accessory, device, material or type of construction, whether to existing or to the
specified equipment, which may be necessary to incorporate the specified equipment into the
existing equipment shall be considered to be a part of these specifications whether detailed by
item or not.
Workmanship shall be the best quality, executed by workers experienced and skilled in the
respective duties.
Yes ____
RFQ (Goods and Services) No.: 1220-41-25-09
No ____
6
3.
REFERENCES
All references to Codes, Standards and general and technical Specifications & Requirements
referred to in these specifications or used on drawings shall mean and intend to be the currently
adopted edition, amendment and revision of such reference standards in effect at the time of
RFQ Closing.
Referenced standards and code requirements shall be considered minimum requirements.
Applicable portions of standards used that are not in conflict with the agreement documents are
hereby made a part of the specifications.
Modifications or exceptions to standards shall be considered as amendments, and unmodified
portions shall remain in full effect.
In cases of discrepancies between the specifications and Standards, the requirements of the
specifications shall govern.
Where references to codes or standards are used in these specifications, the Contractor must
familiarize himself with the applicable portions and shall be governed by them.
If requested, the Contractor shall furnish an affidavit from manufacturers certifying that materials
or products delivered meet the requirements specified. However, such certifications shall not
relieve the Contractor from the responsibility of complying with any added requirements
specified in the agreement documents.
Yes ____
4.
No ____
DESIGNATION EXPLANATION
Items not described in this specification for the construction or performance or in ULC S515
Standards or CAN/ULC S515-04, or NFPA 1901 [latest edition(s)] may be accepted as the
standard of the Contractor. The primary objective of these specifications is to obtain the best
value and most acceptable apparatus for use by the City’s Fire Department.
These general and technical specifications cover specific requirements as to the type of
construction and tests as to which the apparatus must conform, together with certain details as
to finish, material preferences, equipment and appliances with which the successful Contractor
must conform. Minor details of construction and materials, where not otherwise specified, are
left to the discretion of the Contractor, who shall be solely responsible for the design and
construction. The apparatus shall conform to the current NFPA Standard for Fire Apparatus to
the extent as herein specified.
The apparatus shall comply with the Canadian Federal Government Motor Vehicle Safety Act
and Regulations; Canadian Motor Vehicle Safety Standards [CMVSS]; and Province of British
Columbia Motor Vehicle Act and Regulations relating to commercial vehicles as well as to
vehicles used for fire fighting, and emergency vehicles at time of agreement signing. The
Contractor will be solely responsible for the design, construction and performance of the
apparatus and shall also meet the requirements of the Workers’ Compensation Board [WCB] for
the Province of British Columbia.
The delivered Fire Apparatus shall have a certified Province of British Columbia G.V.W.R.
weight sticker applied to the apparatus on delivery to ensure the apparatus meets all laws
pertaining to the weight carrying capacity of the vehicle.
All items listed in the specification are to be considered mandatory except work and equipment
listed as optional. Any Contractor must agree to price and perform all work and provide all
RFQ (Goods and Services) No.: 1220-41-25-09
7
equipment listed in the specification. It is understood that the City may select or delete items
listed as options as necessary when accepting a Quotation.
Whether specifically mentioned herein or not, all parts necessary to provide complete and
efficient Fire Apparatus shall be furnished. Such parts shall conform to the best current
engineering practices of the industry relative to design, structure, quality of materials and
workmanship.
Yes ____
5.
No ____
BUILD SCHEDULE
The successful Contractor will:
(a)
prepare and submit a horizontal bar chart [final build schedule] within Ten (10) days after
the pre-construction meeting, indicating the timing (start and completion date of activities
noting the first work day of each week) of all major activities of the work, providing a
separate bar for each trade or operation including, mechanical, plumbing and electrical
work, and provides details of the critical events and their inter-relationship to
demonstrate the work will be performed in conformance with the agreement time;
(b)
monitor the progress of the work relative to the construction schedule and update the
schedule on a monthly basis for review by the City Representative, at time of submission
for application for payment and as stipulated by the agreement documents;
(c)
promptly advise the City of any revisions required to the schedule;
(d)
indicate changes occurring since previous submission of schedule such as major
changes in scope, activities modified since previous submission, revised projections of
progress and completion, and other identifiable changes;
(e)
provide a narrative report to define problem areas, anticipated delays, the impact on the
schedule, corrective action recommended and its effect; and,
(f)
submit a construction schedule and itemize activities separately for each phase.
Yes ____
6.
No ____
SHOP DRAWINGS
Drawings for approval and blueprints with all details thereon must be furnished within ten (10)
days after the pre-construction meeting and before the construction of the Fire Apparatus
begins.
The Contractor will be required to provide three (3) sets of detailed shop drawings. Shop
drawings shall be formatted so that there is sufficient space for Contractor’s circulation stamps
to appear on the face of the submittal.
One print will be returned with appropriate notation if a re-submittal is required.
The Contractor shall provide a five (5)-view drawing showing overall dimensions and
configuration of Fire Apparatus and arrangement of compartments and equipment storage. The
five views shall be as follows:
RFQ (Goods and Services) No.: 1220-41-25-09
8





top view [entire truck]
front end view
rear end view;
Left side view; and,
right side view;
The drawings shall clearly indicate to scale, all exterior portions of the proposed Fire Apparatus,
controls, lights, railings, gauges, etc. This drawing must be approved by the City prior to
construction of the Fire Apparatus.
Each Contractor shall make accurate statements in their specifications as to weight, wheelbase,
and other principal dimensions such as overall length, height, width, compartment sizes, door
openings, etc.
The body manufacturer shall submit all applicable drawings, and calculations to the City with the
Quotation package. Drawings supplied with this document are for evaluation purposes, and are
not intended to assist with the production of design and manufacturing drawings for the project.
No Quotation shall be considered unless complete engineering drawings to the Quotation
Specifications are submitted with the Quotation package. Failure to submit factory prepared
drawings may result in rejection of the Quotation. The engineering drawings will allow the City
the ability to fully evaluate each Quotation, design, engineering and drawing quality in
comparison to the specifications.
CONTRACTOR TO STATE:
Engine Weight and Electrical Data 2;
Engine performance computer generated scans shall be submitted with Quotation indicating
gross and net horsepower and torque, full throttle performance and Apparatus full throttle
acceleration indicating speed, time, distance and engine R.P.M. through all gear ranges at 0%
grade;
G.V.W.R. front, rear, and total weight computer analysis, with proposed City equipment
mounted in noted locations, including personnel shall be submitted with Quotation;
Computer electrical analysis of "response" and stationary "on scene" modes of electrical
operations and equipment shall be submitted with Quotation;
Compartment sizes and locations;
Showing weight distribution, front and rear, and the centre of gravity of the apparatus when fully
loaded;
Ladder storage and ladder locking system;
Schematic piping layout of the hydraulic system with all major components described; and,
Showing the valves and piping layout of the fire pump system with all major components
described.
Photocopied product literature will not be accepted as shop drawings.
The term “by others” shall not be used on shop drawings or other submittals, the related trade or
subcontractor shall be stated by the Contractor.
Where the specifications require shop drawings to bear the seal of a professional Engineer, the
Engineer must be registered in the province/state where the project is located and shall have
expertise in the area of practice reflected by the shop drawings.
Yes ____
RFQ (Goods and Services) No.: 1220-41-25-09
No ____
9
7.
PRODUCT DATA
Certain specification sections specify that manufacturer’s standard schematic drawings,
catalogue sheet(s), diagrams schedules, performance charts, illustrations and other standard
descriptive data will be accepted in lieu of shop drawings.
The above will only be accepted if they conform to the following:
(a)
(b)
(c)
(d)
(e)
Clearly mark each copy to identify pertinent products or models;
Show performance characteristics and capacities;
Show dimensions and clearances required, relative to apparatus requirements;
Show wiring or piping diagrams and controls; and,
Supplement standard information to provide information specifically applicable to the
Work.
A complete set of Contractors specifications, with generic scale drawings, showing the front,
rear, left, right, front and top views of the proposed apparatus must be submitted with your
quotation for the purposes of comparison. Include catalogue information, descriptive literature,
specifications and/or engineering drawings that completely identify the items proposed.
Yes ____
8.
No ____
SPECIFIED EQUIPMENT, OR EQUIVALENT
Wherever in the specifications any materials or processes are indicated or specified by patent of
proprietary name and/or by name of manufacturer, such specifications shall be deemed to be
used for the purpose of facilitating descriptions of the performance, materials and/or processes
desired and shall be deemed to be followed by the words, “or equivalent”, if not so stated in the
specifications herein.
The burden of proof shall rest with the Contractor, the course of a technical evaluation, to prove
that the proposed item(s) are equivalent to the performance, materials, processes, or articles
specified. Determination as to whether the item(s) is/are equivalent to those as specified shall
rest solely with the Department Representative, or designate.
Yes ____
9.
No ____
PRODUCT OPTIONS
For product specified only by referenced standards select any product, which meets or exceeds
the standard.
For products specified by naming several products or acceptable manufacturers select any
product named. If a standard is also referenced, verify that the product selected meets the
standard.
For products specified by “generic” specification: Select any product meeting or exceeding
specification.
Where the specification provides for selection of an option which is not consistent with the
drawings and schedules (as in the case of a piece of equipment which differs from the
equipment detailed in dimensions, service requirements, etc.), the Contractor, if he elects to use
this option, agrees to coordinate the installation of the selected option into the Work, making
such changes in the work as may be required to accommodate the option, and he will bear and
waives all claims for additional compensation for costs which subsequently become apparent
arising out of the option, including costs of re-design, and preparation of drawings and details.
Products specified by brand name, make, name of manufacturer, trade name, catalogue
RFQ (Goods and Services) No.: 1220-41-25-09
10
number, model number or similar reference shall be regarded as establishing a standard. It is
not intended to rule out competition from equal brands or makes. If, however, a product other
than that specified is proposed, it is the Contractor’s responsibility to name such a product in its
Quotation. Evidence of equality in the form of samples may be requested. Determination of
equality shall be at the sole discretion of the City whose decision will be final.
Yes ____
10.
No ____
SUBSTITUTIONS
Quotations for substitution may be submitted by the Contractor only after award of agreement.
Such requests must include statements of respective costs of items originally specified and
proposed substitutions.
Within twenty (20) days after letter of intent to award, the City will consider formal requests from
the Contractor for changes to be made to the agreement to substitute other products for those
specified. Before the end of this period verify that the products where specified can be
obtained, meet all requirements and submit requests for substitutions for products which cannot
be obtained.
The City will consider Quotations if:
(a)
products selected by the Contractor from those specified are not available, or;
(b)
delivery date of products selected from those specified would unduly delay
completion of the agreement, or;
(c)
alternative products or construction methods to those specified, which are brought to
the attention of, and considered by the City as equivalent to those specified, will
result in credit to the agreement amount.
With Quotations for substitution include:
(a)
complete data substantiating compliance of the proposed substitute with agreement
requirements;
(b)
For products: Product identification, including manufacturer’s name and address;
manufacturer’s literature, including product description, performance test data,
reference standards, and limitation, samples, if appearance is relevant; name and
addresses of similar projects where the product has been used;
(c)
For construction methods:
drawings illustrating it.
(d)
itemized comparison of proposed substitution with product or method specified;
(e)
data relating to changes in schedule;
(f)
quotation for change in agreement amount if substitution is approved; and,
(g)
verification that product complies with various codes.
Detailed description of the proposed method, and
Should proposed substitution be accepted, in part or in whole, assume full responsibility and
costs when substitution affects any other Services. Pay for any drawing changes required as a
result of substitution. Drawings incorporating and coordinating all aspects of affected Services
shall bear the seal and signature of an engineer registered in the Province/State of the Services.
RFQ (Goods and Services) No.: 1220-41-25-09
11
In making a Quotation for substitution the Contractor represents: That he has personally
investigated the RFQ and (unless the Quotation explicitly states otherwise) determined that it is
equivalent or superior to the product or method specified; that the same guarantee will be
furnished for the original; that he will coordinate installation of the accepted substitute in the
Services, making such changes in the Services as may be required to accommodate the
change; that he will bear and waives all claims for additional compensation for costs which
subsequently become apparent arising out of the substitution; and that the Quotation is
complete and includes all related costs.
Substitutions will not be considered which are implicit in submitted shop drawings and samples
rather than formally presented Quotations as described above.
Substitutions will not be considered which require substantial changes in the Agreement
documents.
No substitutions will be permitted without the written approval of the City.
Substitutions will not be considered which are due to negligence in not ordering specified
product in proper advance time considering place of origin of product, normal method of delivery
and manufacturer’s ordering requirement. In the case of the preceding, the City will select a
substitute, which the Contractor shall provide and install at no additional cost to the City.
Yes ____
11.
No ____
GENERAL CONSTRUCTION AND DESIGN
All work shall be carried out in a professional workmanlike manner.
The apparatus and all major components shall be manufactured in North America.
All oil, hydraulic and air tubing lines and electrical wiring shall be located in protective positions
properly attached to the frame or body structure and shall have protective loom or grommets at
each point where they pass through structural members, except where a through-frame
connector is necessary.
Parts and components should be located or positioned for rapid and simple inspection and
recognition of excessive wear or potential failure. Whenever functional layout of operating
components determines that physical or visual interface between items cannot be avoided, the
item predicted to require the most maintenance shall be located for best accessibility.
Cover plates, which must be removed for component adjustment or part removal, should be
equipped with quick-disconnect fastenings or hinged panels.
Drains, filler plugs, grease fittings, hydraulic lines, bleeders and check points for all components
should be located so that they are readily accessible and do not require special tools for proper
servicing. Design practices should minimize the number of tools required for maintenance.
Exceptions will not be accepted or permitted since all raw materials of specified type are
available to all manufacturers. Since all fire manufacturers have the ability to shear, brake and
weld, as these specifications require, all basic design requirements shall be complied with.
Materials shall conform to the specifications listed herein. When not specifically listed, materials
shall be of the best quality for purpose of commercial practice. Materials shall be free of all
defects and imperfections that might affect the serviceability of finished product.
All nameplates and instruction plates shall be metal with the information engraved, stamped, or
etched thereon, as required by NFPA #1901 [latest edition(s)].
RFQ (Goods and Services) No.: 1220-41-25-09
12
Name plates shall show make, model, serial numbers, or other such data necessary to
positively identify the item and all fluid types and levels for vehicle. All plates shall be mounted
in a conspicuous place with stainless steel screws and bolts, as required by NFPA #1901 [latest
edition(s)].
The manufacturing process, including quality control, shall be consistent with present industry
standards. All equipment, materials and articles required under this specification are to be new
or fabricated from new materials produced from recovered materials. The term “Heavy Duty”,
as used to describe an item, shall mean in excess of the standard, quantity, quality, or capacity
and represents the best, most durable, strongest, etc., part, component, system, etc., that is
currently available. The City shall be the sole judge of quality, construction and stability of the
apparatus and equipment being offered.
Defective components shall not be furnished. Parts, equipment and assemblies, which have
been repaired or modified to overcome deficiencies, shall not be furnished without the approval
of the City. Welded, bolted, and riveted construction utilized shall be in accordance with the
highest standards of the industry. CWB/AWB Certified welders must perform all welding.
Component parts and units shall be manufactured to definite standard dimensions with proper
fit, clearances, and uniformity. General appearance of the vehicle shall not show any evidence
of poor quality of work.
Yes ____
12.
No ____
PRE-CONSTRUCTION CONFERENCE
A qualified engineer of the body manufacturer is to meet with the City to discuss all facets of
these specifications to ensure a complete and satisfactory understanding of the City’s
specifications and Contractor’s Quotation. A pre-construction meeting will be held at the
Contractor’s facility. The Contractor will provide, arrange and pay for all direct and associated
travel costs for this meeting. For scheduling purposes, notification of the pre-construction
conference shall be a minimum of fourteen (14) days before the date. N.B. Arrangements and
dates for the pre-construction conference must be made within three (3) weeks following
date of award.
Yes ____
13.
No ____
QUALITY AND WORKMANSHIP
The design of the Fire Apparatus must embody the modular design and construction technique
as outlined.
The workmanship must be of the highest quality in its respective field(s). Special consideration
will be given to the following points:
(a)
(b)
accessibility of the various components which require periodic maintenance operations;
and,
ease of operation, including both pumping and driving operations and symmetrical
proportioning of the overall apparatus.
Welding shall not be employed in the assembly of the apparatus in a manner that will prevent
the removal of major component parts for service and/or repair. This includes, but is not limited
to the following:
(a)
(b)
(c)
(d)
individual body compartments;
doors;
panbraces;
body subframe,
RFQ (Goods and Services) No.: 1220-41-25-09
13
(e)
(f)
bodysides;
beavertails, etc.
N.B. ALL WELDING MUST BE DONE BY CWB/AWB CERTIFIED WELDERS, NO
EXCEPTIONS.
The Contractor shall certify that all components of the drive train are compatible and will stand
the strain of Fire Department use, and still bear the Manufacturer’s normal warranty. It will be
the responsibility of the Contractor to check with the manufacturer of the chassis in this regard
and inform the City of any change that may be necessary in the specifications so they will
conform to standards.
The provision of these specifications are to be complied with in all respects, except in instances
whereby variances have been granted. In the event the Contractor cannot supply specified
items for reasons of non-compatibility, or reasons beyond the Contractor’s control, he shall
request a variance to provide substitute items, equal to or better, describe these items in detail
in writing to the City.
The design of the apparatus shall be modern, employing the latest automotive engineering
practices designed to suit the nature of the services, which the apparatus must perform. Frame,
springs, radial arms, transmission, differential, axles, shafts and gears shall be strong enough to
withstand the road speed and practical tests, and the unusual stresses and strains place on
such apparatus in the fire fighting service. All of the equipment furnished shall be the
manufacturer’s current published data. If specifications exceed these, or the Contractor sees fit
to add extra features, they shall be considered as minimum and be furnished.
All areas shall be primed with the highest quality products available before being hidden by
body construction, or finished paint.
Yes ____
14.
No ____
DOCUMENTATION AT TIME OF DELIVERY
The successful Contractor will be required provide the following documentation upon delivery:
.1
All keys [two (2) full sets], parts and service manuals are to be delivered with the vehicle;
.2
Manufacturer’s Certificate of Origin;
.3
Warranty document(s) and/or certifications as may be required in the Specifications;
.4
Two complete overhaul manuals to cover engine, transmission, rear axle, electrical
components, etc. to cover completed apparatus. They will include wiring schematics of
chassis;
.5
One parts catalogue to cover complete drive train and any equipment supplied with
apparatus;
.6
Two pump manuals covering repair and operation of pump;
.7
Two sets of electrical wiring schematics to cover any and all wiring not installed by
chassis manufacturer. This diagram to include part numbers and brand names of
switches, lights, etc. of parts used;
.8
Calculations showing grade ability and speed;
.9
Any special tools that are required in the care and maintenance or overhaul of the
apparatus and its components; and,
.10
A complete list of all belts, hoses, and filters; to include part numbers, manufacturer and
use.
Yes ____
RFQ (Goods and Services) No.: 1220-41-25-09
No ____
14
15.
DELIVERY
The Fire Apparatus and equipment specified herein, with delivery tickets and/or other required
documentation will be delivered prepaid F.O.B. Destination, between the hours of 8:00 a.m. to
3:30 p.m., Monday through Friday, to City of Surrey, Surrey Fire Hall #9, Mechanical Division,
14901 – 64th Avenue, Surrey, BC CANADA.
The Contractor will notify the City, not less than 5 days prior to expected delivery/arrival to
permit final inspection scheduling. An authorized representative of the Contractor shall
supervise delivery to the City. The City will not assume any liability for vehicle/equipment
delivered to an unauthorized location.
Title, Risk of Loss, Freight: Title of goods received under this contract shall remain with the
Contractor until they are delivered to the address specified, at which time title passes to the City
of Surrey. Regardless of FOB point, Contractor agrees to bear all risks of loss, injury, or
destruction of goods and materials ordered herein which occur prior to delivery and acceptance.
Such loss, injury, or destruction shall not release Contractor from any obligations under. Prices
include freight prepaid. Contractor assumes the risk of every increase, and receives the benefit
of every decrease, in delivery rates and charges.
Yes ____
16.
FACTORY INSPECTION TRIPS
16.1
Inspection Visits
No ____
The Contractor will provide, arrange and pay for all direct and associated travel costs of one
City staff for the following inspection visits:
Inspection #1: inspection of cab, chassis and main fire pump;
Inspection #2: inspection of pump installation, all plumbing, and structural body installed, and,
primed and ready for paint; and,
Inspection #3: (pre-delivery) when Fire Apparatus is complete and ready for shipment to the
City.
Factory inspection trips shall be of a minimum three (3) day duration; include commercial
transportation (i.e. airfare), meals, accommodation [lodging], and local transportation to and
from plant facility and be conducted during normal business hours Monday through Friday.
In addition, the City reserves the right to visit the manufacturer’s facility at any time at no cost to
the Contractor, to monitor the construction of the apparatus. Advance notice of these visits will
be made prior to arrival.
The Fire Apparatus must be in finished condition and ready for shipment when the pre-delivery
inspection is scheduled.
A road performance test, pump test, foam delivery test and general operation demonstration
must be performed during the pre-delivery inspection.
Certificates of third party testing of the pump must also be available for inspection.
Yes ____
16.2
No ____
Inspections [Manufacturer’s Facility]
All or any part of the work and all workshops or other places where material for the works is
being prepared or stored, may be inspected by the City, when the City shall deem it expedient,
RFQ (Goods and Services) No.: 1220-41-25-09
15
consistent with the terms of inspection of the specifications. The Contractor shall afford the
City, every facility and access request by him and shall give him any and all information
requested by him in connection therewith. No payment will be made for the cost to the
Contractor of any work delay occasioned by such inspection and no extension of time will be
allowed for any delay occasioned thereby.
All materials or equipment shall be subject to inspection or test and shall meet the approval of
the City. Such inspection, at the option of the City, may be carried out at the place of business
of the Contractor.
Should materials or equipment be found defective in quality of workmanship or otherwise fail to
conform with the specifications set forth, the City shall have the right to reject them or require
their immediate correction.
Materials or equipment requiring correction shall be removed for correction or corrected in place
as requested by the City at no expense to the City. Unavoidable expense encountered by the
City shall be chargeable to the Contractor and deducted from any monies owing to the
Contractor by the City.
If the Contractor fails to take proper action promptly when requested by the City, the City may
replace or correct materials as necessary and charge the cost of such replacement to the
Contractor or the City may terminate the agreement as provided for herein.
If the Contractor covers, or permits to be covered, work that has been designated for special
tests, inspections, or approvals before such tests, inspections, or approvals are made, given or
completed, the Contractor shall, if so directed, uncover such work, have the inspections or tests
satisfactorily completed, and make good covering the work at the Contractor’s expense.
The City may order any portion or portions of the work to be examined to confirm that such work
is in accordance with the requirements of the RFQ. If the work is not in accordance with the
requirements of the RFQ, the Contractor shall correct the work and pay the cost of examination
and correction.
Yes ____
16.3
No ____
Pre-Delivery Service
After transportation from the factory and immediately prior to delivery, the apparatus shall
receive a pre-delivery service consisting of engine oil and filter change, chassis lubrication,
adjustment of the engine to manufacturer’s specifications, and a complete inspection including
all electrical and mechanical devices for proper operation and correction of leaks or obvious
problems.
Upon delivery the Fire Apparatus shall be delivered clean and shall be complete with all
equipment operable. The delivered Fire Apparatus will be inspected for compliance with the
City’s specifications, NFPA 1901 – latest edition and previously authorized exceptions.
The checklist developed during the preliminary inspection at the manufacturer’s site will be used
to verify that all items previously identified, as deficient/defective/unacceptable were
corrected/replaced.
Deviations will not be acceptable unless they were noted and accepted by the City as
exceptions/substitutions.
The Fire Apparatus and equipment will only be accepted by the City upon successful completion
of all required tests and delivery of all specified equipment.
Equipment items not delivered at time of tests or construction not in conformance with the
requirements will be cause for the City to withhold payment.
RFQ (Goods and Services) No.: 1220-41-25-09
16
Each Fire Apparatus shall be inspected by the City to determine its compliance with the
specifications and/or to test its ability to perform its intended use.
In the event the apparatus fails to meet the test requirements on first trials, second trials may be
made at the option of the Contractor within thirty (30) days of the day of the first trials.
Such trials shall be final and conclusive; and failure to comply with these requirements shall be
cause for rejection.
Acceptance will only occur upon issuance of a formal written acceptance signed by the City.
Yes ____
16.4
No ____
Delivery Engineer
The Fire Apparatus shall be delivered to the City with full instructions provided to City personnel
on operation, care, and maintenance of apparatus at the City's fire station.
Delivery shall be performed by a factory trained Contractor’s representative. Delivery by driveaway shall not be acceptable. The Contractor’s representative shall remain on-site for a
minimum of three (3) days after receipt of goods, for training of City personnel and the making
of normal adjustments.
Delivery shall be considered to include, but not be limited to: transportation of the Fire
Apparatus, conducting day and/or evening classes for instruction of City personnel on
operations and for maintenance and repair.
Yes ____
16.5
No ____
Performance Tests and Requirements
The Fire Apparatus shall meet the following requirements:
A.
The Fire Apparatus shall be tested and approved by Underwriter’s Laboratories of
Canada in accordance with ULC S515 Standards or CAN/ULC S515-04, or NFPA 1901
[latest edition(s)].
B.
The Contractor will furnish copies of
(i)
pump manufacturer’s certification of Hydrostatic Test;
(ii)
the engine manufacturer’s current Certified Brake Horsepower curve; and,
(iii)
a current EPQ for the engine and the manufacturer’s record of Fire Apparatus
construction details, when delivered.
The Contractor, at his sole expense, shall have the Underwriters Laboratories of Canada
conduct the tests required under “Certification of Fire Department Pumper”, latest version. A
certificate of compliance with these tests shall be forwarded to the City.
In the event the apparatus fails to meet the requirements of these tests and specifications on
first trials, second trials may be performed at option of the Contractor within thirty (30) days of
the date of first trials. Such trials are to be witnessed by the City and completed at the expense
of the Contractor. Such trials shall be final and conclusive and failure to comply with these
requirements shall be cause for rejection. Failure to comply with changes, as the City, may
consider necessary and to conform to any clause of these specifications within thirty (30) days
after written notice of such changes is given to Contractor shall be cause for rejection of the
apparatus.
Yes ____
RFQ (Goods and Services) No.: 1220-41-25-09
No ____
17
17.
WARRANTIES
The Contractor warrants that the Fire Apparatus shall be free from defects in design, materials,
workmanship and title, shall conform in all respects to the terms of this supply agreement, shall
be fit and suitable and perform satisfactorily for the purposes and under the conditions made
known to the Contractor by the City or which were reasonably inferable. The Fire Apparatus
shall be at least equal to the higher of national standards or codes (such as, by way of
illustration, CSA or ASTM), or standards and codes customarily applicable at the place where
the City will use the Goods. The Fire Apparatus shall be of the best quality, if no quality is
specified. This general warranty is independent of and without prejudice to any specific
warranty or service guarantee offered by the Contractor in connection with the purpose for
which the Fire Apparatus were purchased. If the Fire Apparatus or any part does not conform to
these warranties one year from the date of delivery or installation, the City shall notify the
Contractor within a reasonable time after such discovery, and the Contractor shall then promptly
correct such nonconformity at its expense. Fire Apparatus used to correct nonconformity shall
be similarly warranted for one year from the date of installation. Except as otherwise provided
in this supply agreement, the Contractor’s liability shall extend to all damages caused by any
breach of any of the above warranties.
The Contractor shall assist the City in the submission of warranty claims on all major
components, such as the engine, transmission, pump, tank, etc.
The Contractor shall provide a full statement of the warranty period and terms, including
extended warranty options, for the following items, as a minimum. This warranty should clearly
describe the terms under which the vehicle's manufacturer or subcontractors of the
manufacturer accept responsibility for the cost to repair defects caused by faulty design, quality
of work or material and for the applicable period of time after delivery.
• Frame Lifetime
• Cab
• Engine
• Transmission
• Axle
• Intake and Discharge
plumbing
• Fire Pump
• Corrosion [against
perforation]
• Siren
• Paint
• Structural [Body]
• Paint [against cracking,
checking or peeling and
loss of gloss caused by
chalking or fading]
• Intercom System
Detail the warranty coverage for any hardware items in the proposed solution including parts,
labour, travel allowance and length of warranty.
Any standard warranties, including, but not limited to engine, transmission, tires and axles
furnished by the original equipment manufacturer (OEM) will be passed on to the City.
The Contractor to submit their own printed manufacturer warranty forms in exact compliance to
the above minimum standards, without exceptions. All warranties shall be submitted and
certified by various manufacturers, (warranties by sales representatives, manufacturer's
representatives or other agencies shall not be acceptable).
The Contractor shall make no representation that the apparatus has the capacity to perform any
functions other than as contained in the Company's written literature, catalogues or
specifications accompanying delivery of the apparatus. No person or affiliated company
representative is authorized to give any other warranties or to assume any other liability on
RFQ (Goods and Services) No.: 1220-41-25-09
18
behalf of manufacturer in connection with the sale, servicing or repair of any apparatus
manufactured by the Company.
The Contractor shall warrant to the City that this apparatus body (exclusive of paint, finish,
hardware, mouldings, windows, and other accoutrements and accessories) is structurally sound
and free of all structural defects of both material and workmanship and further warrant that it will
maintain such structural integrity for a period of fifteen (15) years from date of manufacture, as
designated on the manufacturer's certification plate attached thereto.
Yes ____
18.
No ____
MANUALS
To ensure the City a source of service and parts over the anticipated life of the apparatus, the
Contractor shall have established their permanency in the industry and include in the Quotation
a description of their full time local service centre abilities and facilities.
The local service centre, the body and chassis manufacturer must stock a complete line of all
fire fighting equipment and parts for this apparatus. Location of manufacturing plant and
nearest service facility to be included in an accompanying letter.
The body manufacturer shall provide with the vehicle on delivery, two (2) complete delivery
manuals. These manuals to be in three-ring notebook type binders, with reference tabs for
each section of the vehicle. Within each section shall be:
Individual component manufacturer instruction and parts manuals;
Warranty forms for body;
Warranty forms for all major components;
Warranty instructions and format to be used in compliance to warranty obligations;
Electrical wiring diagrams of each body circuit. These drawings must be “as-built”, generic or
similar-to drawings will not be accepted. All fuse, strobe power supplies, diodes and circuit
locations shall be identified;
Necessary normal routine service forms, publications, component of body portion of apparatus;
Technical publications on training and instructions for major body components;
Warning notices and safety related section for personnel protection;
Chassis parts, service and maintenance manuals shall be provided; and,
“As Built” air brake diagrams.
Two (2) maintenance manuals and supplement shall be supplied at the time of delivery for each
unit and must include:
Complete recommended maintenance procedures for all components supplied by the
manufacturer to meet the requirements of this specification.
Specification and a list of approved North American manufactured products for fuel and all
lubricant requirements. A label with all lubricant types and fluid amounts shall be installed on
vehicle driver's door, per NFPA #1901 (current edition).
Yes ____
RFQ (Goods and Services) No.: 1220-41-25-09
No ____
19
19.
RECALL NOTICES
In the event of any recall notice, technical service bulletin, or other important notification
affecting a unit purchased from this agreement, a notice shall be sent to the City. It shall be the
responsibility of the Contractor to assure that all recall notices are sent directly to the City.
Yes ____
20.
No ____
IN-SERVICE TRAINING
The Contractor will provide the following training to the City’s Fire Department, mechanical
personnel:
Fire Apparatus operators will be trained in the operation of all chassis and body functions,
including operator preventive maintenance; technicians will be trained in all operator functions,
in-depth troubleshooting for all major chassis and body systems, engine tune-up procedures,
transmission maintenance and repair, and chassis and body maintenance and repair.
The trainer shall be factory-trained and thoroughly knowledgeable in subjects to be taught,
including but not limited to subjects as outlined above.
Refresher training will be accomplished annually. Periodic training on machine systems and
components will be provided as requested by the City.
Yes ____
No ____
21. PROJECT RECORD DOCUMENTS
21.1
Requirements Included
Record documents, samples, and specifications
Equipment Systems
Product data, materials and finishes, and related information
Operation and maintenance data
Warranties
21.2
Related Requirements
Shop drawings, product data and samples
Construction Schedule
Individual Specifications: Specific requirements for operation and maintenance data.
21.3
Quality Assurance
Prepare instructions and data by personnel experienced in maintenance and operation
of described products.
21.4
Format
Organize data in the form of an instructional manual, index by specification.
Binders; commercial quality, 215mm x 279mm, maximum size, ring style.
When multiple binders are used, correlate data into related consistent groupings.
Cover: Identify each binder with typed or printed title “Project Record Documents”, list
title of project and identify subject matter of contents.
Arrange content under section numbers and in same sequence as Table of Contents.
Provide tabbed fly leaf for each separate product and system, with typed description of
product and major component parts of equipment.
Tests: Manufacturer’s printed data or typewritten data on 20lb. paper.
Submit sample binder and index for review & approval prior to proceeding.
RFQ (Goods and Services) No.: 1220-41-25-09
20
21.5
Contents Each Volume
Table of Contents: Provide title of project: names, addresses and telephone numbers of
Contractor with name or responsible party; schedule of products and systems, indexed
to content of the volume.
For Each Product of System: List names, addresses and telephone numbers of
subcontractors and contractors, including local source of supplies and replacement.
Product Data: Mark each sheet to clearly identify specific products and component
parts, and data applicable to installation; delete inapplicable information.
Drawings: Supplement product data to illustrate relations of component parts of
equipment and system, to show control and flow diagrams.
Type Text: As required to supplement product data. Provide logical sequence of
instructions for each procedure, incorporating all manufacturers’ instructions.
21.6
Submission
Submit two copies of completed volumes in final form 15 days following final acceptance
inspection.
Revise content of documents as identified by the City Representative, or designate.
Submit two copies of revised complete volumes of data in final form as well as one
reproducible copy of all as-built, contract and shop drawings at application for final
payment.
Provide electronic [*pdf] format complete manuals on CD Rom structured per hardcopy
and complete with navigational tools. Information contained within electronic manuals
shall be maintainable and updatable in Microsoft Excel or Word format, balancing
schematic diagrams in AutoCAD [latest version].
21.7
Recording “As Built” Conditions
Record information on a set of blue or blackline drawings and in a copy of project
manual obtained from the City Representative, or designate at the commencement of
the project.
Record information concurrently with construction progress. Do not conceal work until
required information is recorded.
Contract drawings and shop drawings:
construction, including:
Legibly mark each item to record actual
.1
measured locations of internal utilities and appurtenances, concealed elements of
mechanical and electrical services referenced to visible and accessible features of
construction and building grid lines.
.2 field changes of dimension and detail.
.3 changes made by change orders.
.4 references to related shop drawings and modifications.
.5 refer to mechanical and electrical specifications for additional specific technical
requirements.
Specifications: Legibly mark each item to record actual construction, including:
.1
.2
manufacture, trade names, and catalogue number of each project actually installed,
particularly optional items and substitute items.
Changes made by addenda and change orders.
RFQ (Goods and Services) No.: 1220-41-25-09
21
Other Documents: Maintain manufacturer’s certifications, inspection certifications and
field test records required by individual specifications sections.
21.8
Equipment and Systems
Each item of equipment and each system: Include description of unit or system, and
component parts. Give function, normal operation characteristics and limiting conditions.
Include performance curves, with engineering data and tests, and complete
nomenclature and commercial number of replacement parts.
Provide electrical service characteristics, controls and communications.
Include installed colour coded wiring diagrams.
Operating Procedures: Include start-up, break-in, and routine normal operating
instructions and sequences. Include regulation, control, stopping shutdown and
emergency instructions. Include summer, winter and any special operating instructions.
Maintenance Requirements: Include routine procedures and guide for troubleshooting,
disassembly, repair and reassembly instructions; and alignment, adjusting, balancing
and checking instructions.









21.9
Provide service and lubrication schedule, and list of lubricants required.
Include manufacturers’ printed operation and maintenance instructions.
Include sequence of operation by controls manufacturers.
Provide original manufacturer’s parts list, illustrations, assembly drawings and
diagrams required for maintenance.
Provide installed control diagrams by controls manufacturer.
Provide Contractor’s coordination drawings, with installed colour coded piping
diagrams.
Provide charts of valve tag numbers, with location and function of each valve keyed
to flow and control diagrams.
Include test and balance reports.
Additional requirements: As specified in individual specification sections.
Materials and Finishes
Applied Materials and Finishes: Include product data, with catalogue number, size,
composition, and colour and texture designations. Provide information for re-ordering
custom manufactured products.
Instruction for Cleaning Agents and Methods: Precautions against detrimental agents
and methods, and recommend schedule for cleaning and maintenance.
Moisture Protection and Weather-Exposed Products:
Include manufacturer’s
recommendations for cleaning agents and methods, precautions against detrimental
agents and methods, and recommend schedule for cleaning and maintenance.
Additional Requirements: As specified in individual specifications section.
21.10 Warranties
Separate each warranty with index tab sheets keyed to the Table of Contents listing.
List subcontractors, contractor and manufacturer, with name, address and telephone
number of responsible principal.
Obtain warranties executed in duplicate by Contractors, contractors and manufacturers
within ten days after completion of the applicable item of work.
RFQ (Goods and Services) No.: 1220-41-25-09
22
Except for items put into use with the City’s permission, leave data of beginning of time
of warranty until the date of final inspection and acceptance is determined.
Verify that documents are in proper form and contain full information.
Co-execute submittals when required.
Retain warranties until time specified for submittal.
Yes ____
RFQ (Goods and Services) No.: 1220-41-25-09
No ____
23
PART II – TECHNICAL SPECIFICATIONS &
REQUIREMENTS
PURCHASE TWO (2) ONLY 7000 L.P.M. TRIPLE COMBINATION PUMPER UNITS
REFERENCE No.: 1220-41-25-09
RFQ (Goods and Services) No.: 1220-41-25-09
24
PART II – TECHNICAL SPECIFICATIONS AND REQUIREMENTS
TYPE OF VEHICLE
The vehicle detailed in this specification is a 7000 L.P.M. Triple Combination Pumper unit.
This vehicle must comply with all D.O.T. and British Columbia Motor Vehicle Act regulations.
STATE WARRANTIES
Cab Basic:
_____________
Cab Paint:
_____________
Frame Rails: _____________
Body Basic: _____________
Body & Structural Integrity: ______________
Body Paint Warranty:
___________
Body Corrosion Warranty:
______________
OVERALL HEIGHT
STATE:
OVERALL LENGTH
STATE:
CHASSIS WHEELBASE
STATE:
TURNING RADIUS
STATE:
CAB AND CHASSIS
The cab and chassis shall be a medium four door, 10" raised roof over crew and driver-officer
area, aluminum tilt cab, built specifically for the fire service by a publicly held U.S. parent
company, specializing in chassis design for all fire service applications. The cab and chassis
shall meet the requirements of the National Fire Protection Association Standard 1901, (2003
edition or latest edition).
Yes ____
No ____
FRAME
The frame side rails shall be "C" channel type, min. 10.25" x 3.5" x .38" 110,000 psi minimum
yield high strength steel.
State number of crossmembers.
The area between the axle suspension hangers shall be free of any holes or fasteners in the
flanges. No welding shall be incorporated in attachment of components. All frame dimensional
cutting shall be done by a plasma cutter. All relief areas shall be cut in with a minimum 2"
radius at intersection points with ground smooth edges to prevent a stress focal point.
The frame and crossmembers shall carry a lifetime warranty to the original purchaser.
Yes ____
RFQ (Goods and Services) No.: 1220-41-25-09
No ____
25
PAINT FRAME AND CHASSIS UNDER CARRIAGE
The chassis under carriage consisting of frame, axles, driveline running gear, battery boxes, air
tanks and other assorted chassis mounted components shall be painted with standard black
paint. Paint shall be applied before airlines and electrical wiring is installed.
Yes ____
No ____
FUEL TANK
The fuel tank shall have a minimum capacity of sixty-eight (68) gallons. The baffled tank shall
be made of 14 gauge aluminized steel. The tank exterior is painted with a primer and top coat.
The fuel tank shall be mounted under the frame, behind the rear axle on strap hangers with a
"U" strap bolted front and rear so the tank can be easily dropped and removed. Tank shall have
vent port to facilitate rapid filling without "blow-back". A roll over ball check vent shall be
installed.
Dual draw tubes and dual sender ports shall be installed. A 2" NPT fill port shall be available for
right hand fill. A 1/2" NPT drain plug shall be centered in the bottom of the tank.
Yes ____
No ____
FRONT BUMPER
A one piece, 10 gauge 304 polished stainless steel front bumper shall be provided. The bumper
shall be 101" wide and 12" high, two (2) rib wrap-around type.
The bumper shall be extended 21” ahead of the cab.
Yes ____
No ____
BUMPER APRON
A 3/16" bright embossed aluminum tread plate apron shall be installed between the bumper and
the front face of the cab. Stainless steel bolts shall be used to attach the apron to the bumper
flange.
Yes ____
No ____
TOW HOOKS
Two (2) heavy duty chrome plated tow hooks shall be installed under the bumper and bolted
directly to the chassis frame with grade "8" bolts.
Yes ____
No ____
AIR HORNS
Dual Grover Stuttertone 21" air horns shall be recessed in the front bumper, one (1) each on the
driver and officer inboard mounting positions. A 3/8" airline "teed" equal distance from each
horn shall be installed.
Yes ____
No ____
AIR HORN ACTUATION
Air horns actuation shall be accomplished by the steering wheel horn button and a right side
officer's push button switch located on the dash.
Yes ____
No ____
HORN SELECTOR SWITCH
A rocker switch shall be installed in the switch panel between the driver and officer to allow
control to either the air or electric horn from the steering wheel horn button. Electric horn will
sound by default when selector switch is in either position (FMVSS requirement).
Yes ____
RFQ (Goods and Services) No.: 1220-41-25-09
No ____
26
SIREN 10" ELECTRIC
A Federal Q2B 10" electric siren shall be recessed in the right hand side (officer's side) of the
front bumper. Only the motor will be recessed, with the front stator and grille protruding from
the front face of bumper.
Siren shall be activated with foot switch for the driver and an officers panel push button switch.
One (1) siren brake to be provided on the center console that is easily accessible to the Driver
and to the Officer.
Yes ____
No ____
ELECTRONIC SIREN SPEAKER
A Federal Signal MS-100 siren speaker with polished "Electric F" grill mount will be installed on
the outer left hand side of the front bumper extension.
Yes ____
No ____
FRONT AXLE
The front axle shall be an ArvinMeritor MFS-20 with a 3.74" drop and a 71.00" KPI. It shall have
a capacity of 20,000 pounds GAWR.
The springs shall be a taper type, three (3) leaf, 54" long and 4" wide with a Berlin wrapped front
eye. Both spring eyes shall have a case hardened threaded bushing installed with lubrication
counterbore and lubrication land off crossbore with grease fitting. The spring capacity shall
meet or exceed the capacity of the front axle.
The hydraulic power assist steering gear shall be a TRW TAS-65 with a hydraulic power assist
cylinder. A Vickers hydraulic power steering pump shall be gear driven from the engine. The
steering ratio shall be 23.3:1 and have 5.4 turns stop to stop.
Yes ____
No ____
FRONT SHOCK ABSORBERS
Two (2) monotubular design, nitrogen gas charged shock absorbers shall be part of the front
axle suspension. The shocks shall be warranted for a period of five (5) years.
Yes ____
No ____
CHASSIS ALIGNMENT
The chassis frame rails shall be cross-checked for length and squareness. Front and rear axles
shall be laser aligned. Tires and wheels shall be aligned and toe-in set on the front tires at the
chassis manufacturer's facility.
The completed apparatus should be rechecked for proper alignment after the chassis has been
fully loaded.
Yes ____
No ____
Yes ____
No ____
BRAKE DUST SHIELDS
The front axle shall be equipped with brake dust shields.
FRONT AXLE CRAMP ANGLE
The hub piloted, MFS-20 front axle cramp angle shall turn approximately 48 degrees to the left
and a minimum of 44 degrees turning to the right, when using the 385/65R 22.5 front tires.
Yes ____
RFQ (Goods and Services) No.: 1220-41-25-09
No ____
27
FRONT TIRES
The front tires shall be Michelin 385/65R 22.5 18PR "J" tubeless radial XTE2 highway tread with
22.5 x 12.25, ten (10) stud disc wheels. The tires and wheels shall be rated at 20,000 pounds.
Yes ____
No ____
FRONT WHEELS STEEL
The front wheels shall be Accuride hub piloted, white in color, 12.25" x 22.5" steel wheels.
Yes ____
No ____
FRONT WHEEL BEARINGS OIL LUBRICATED
The front axle wheel bearings shall be oil lubricated and come equipped with an oil level visual
inspection window.
Yes ____
No ____
STEERING COLUMN AND WHEEL
The steering column shall be a tilt and telescopic type with an 18" steering wheel. The steering
wheel shall be covered with black absorbite padding.
The steering column shall contain a horn button, self-canceling turn signal switch, four-way
hazard switch and headlamp dimmer switch.
Yes ____
No ____
FRONT BRAKES
The front brakes shall be 16.5" x 6" S-cam type with automatic slack adjusters.
Brakes to have ArvinMeritor automatic slack adjusters.
Yes ____
No ____
Yes ____
No ____
FRONT BRAKE CHAMBERS
Front brake chambers to be standard stroke.
REAR AXLE
The rear axle shall have a fire service rated capacity of 27,000 pounds GAWR.
Yes ____
No ____
TOP SPEED
The top speed of the vehicle shall be approximately 65 MPH +/-2 MPH at governed engine
RPM.
Yes ____
No ____
Yes ____
No ____
BRAKE DUST SHIELDS
The single rear axle shall be equipped with brake dust shields.
REAR BRAKES
The rear brakes shall be 16.5" x 7" S-cam type with automatic slack adjusters.
Brakes to have ArvinMeritor automatic slack adjusters.
Yes ____
No ____
Yes ____
No ____
REAR BRAKE CHAMBERS
Rear brake chambers to be 30-36 standard stroke
RFQ (Goods and Services) No.: 1220-41-25-09
28
ABS & ATC SYSTEM
A Meritor "WABCO" anti-lock braking system shall be installed on the front and rear axles.
Automatic traction control shall be installed on the single rear axle. The traction control shall
apply the brake on slipping wheel end of drive axle and droop electronic engine throttle back to
prevent wheel spin while accelerating on a slippery surface.
A mud and snow switch shall be provided. When the switch is in the "ON" position it will allow
momentary wheel slip to obtain traction under extreme mud and snow conditions.
Yes ____
No ____
REAR TIRES
The rear tires shall be Michelin 12R 22.5 16PR "H" tubeless radial XDN2 mud and snow tread
with 22.5 x 8.25, ten (10) stud disc wheels. Tires and wheels shall be rated at 27,120 pounds.
Yes ____
No ____
REAR WHEELS
The single rear axle wheels shall be Accuride hub piloted, white in color, 8.25" x 22.5" steel.
Yes ____
No ____
PAINTED WHEELS
The wheels on the chassis shall be pretreated in a zinc phosphate bath, and then coated with
an acrylic cathodic electro deposited white primer base coat (E-Coat) by the wheel supplier.
NOTE: Wheels are to be painted WHITE to match the upper paint of the cab. The Hubs to
remain Black.
Yes ____
No ____
HUBODOMETER
A hubodometer shall be installed on the left rear axle shaft. Require one (1) STEMCO DataTrac
Pro to measure kilometers
Yes ____
No ____
Yes ____
No ____
OIL LUBRICATED REAR WHEEL BEARINGS
The rear axle shall have oil lubricated wheel bearings.
REAR SUSPENSION
The rear suspension shall be a Reyco 79KB vari-rate, captive slipper type, with 57.5" x 3"
springs. One (1) adjustable and one (1) fixed torque rod shall be provided.
The spring capacity must meet or exceed the capacity of the rear axle.
Yes ____
No ____
Yes ____
No ____
NUT COVER KIT STAINLESS STEEL (ALL WHEELS)
The front and rear wheels shall have stainless steel lug nut covers.
AUTOMATIC SNOW CHAINS
On Spot chains are to mounted to the rear axle. The chains are to be controlled by a dash
mounted rocker switch.
Yes ____
RFQ (Goods and Services) No.: 1220-41-25-09
No ____
29
SINGLE REAR AXLE AIR BRAKE SYSTEM
A FMVSS 121 and NFPA rapid build-up, compliant air brake system shall be provided. It shall
include three (3) air reservoirs with a total of 4136 cubic inch of air capacity.
Yes ____
No ____
FRONT WHEEL SERVICE BRAKE LOCK-UP SYSTEM
A front wheel service brake lock-up system shall be installed which will apply both the front air
and rear spring brakes upon application of the PP-1 push-pull valve in the cab.
Yes ____
No ____
AIR DRYER
A Meritor Wabco system saver 1200 spin-on desiccant air dryer with a 12-volt, 100-watt
automatic heated moisture ejector shall be installed in the air brake system.
Yes ____
No ____
REMOTE MANUAL AIR DRAINS
Remote manual drains shall be installed on all reservoirs of the air brake system. All drains are
to be remote located to below L1 and name tagged.
Yes ____
No ____
NYLON AIR LINE TUBING
A dual air system plumbed with color coded reinforced nylon tubing air lines shall be installed.
The primary (rear) brake line shall be green, the secondary (front) brake line red, the parking
brake line orange and the auxiliary (outlet) will be blue.
Brass compression type fittings shall be used on the nylon tubing. All drop hoses shall be fiber
reinforced neoprene covered hoses.
Yes ____
No ____
ADDITIONAL AIR RESERVOIR
An additional 1200 cubic inch air reservoir shall be installed and isolated to prevent depletion of
the air to the air brake system and to act as a supply tank for operating air equipment. It shall
be plumbed with a 90 psi pressure protection valve on the reservoir supply side.
Yes ____
No ____
Yes ____
No ____
AIR TANK MOUNTING
The air tanks shall be installed one (1) inch inboard of the frame rails.
OUTSIDE AIR INTAKE CONNECTION
A quick release outside air intake male connector shall be provided in the left cab step area for
shoreline air intake to maintain air system build up. The air connector supplied shall be
compatible with a Lincoln fitting.
The inlet is to be located in the Driver's mid height step adjacent to the shorepower inlet.
Yes ____
No ____
AIR COMPRESSOR
The air compressor on the engine shall be a Wabco capable of producing a minimum of 18.7
cfm at 1250 engine rpm. It shall be gear driven, engine oil pressure lubricated and cooled by
the engine cooling system.
Yes ____
RFQ (Goods and Services) No.: 1220-41-25-09
No ____
30
ENGINE
Prefer; Cummins ISM-400, turbocharged, charge air cooled engine shall be provided.
TYPE:
In-Line six (6) cylinder, 4 cycle
HORSEPOWER:
400 HP at 1900 to 2100 rpm / Governed at 2100 rpm
TORQUE:
1550 lb. Ft. @ 1400 rpm
DISPLACEMENT:
661 cu. in.
GOVERNOR:
Electronic
A wiring harness shall be supplied with a drop out at the back of the cab. The harness shall
include a connector to allow an optional harness for the pump panel to be plugged into it.
Circuits shall be provided for tachometer, oil pressure, engine temperature, hand throttle, high
idle and PSG system. A circuit for J1939 data link shall also be provided at the dropout.
An engine mounted Fleetguard combination full flow/by-pass oil filter with replaceable spin on
cartridge shall be part of the engine's lubrication system.
Yes ____
No ____
ENGINE OIL LEVEL CHECK
A low engine oil level switch shall be provided that will indicate when the engine oil is
approximately four (4) quarts or more low. The switch shall light a red "LOW OIL LEVEL"
indicator light in the dash. The indicator shall only function while the ignition switch is on and
the engine is not running.
Yes ____
No ____
FUEL FILTER - CUMMINS ENGINE
Two (2) Fleetguard fuel filters shall be provided. A combination primary fuel/water separator
shall be remote mounted in an easily accessible location for servicing complete with a water-infuel (WIF) sensor. If water is present in the fuel the sensor shall activate the WIF light and
alarm in the instrument panel.
A secondary filter will be installed on the engine between the fuel pump and the injectors.
A shut off valve is required for servicing of fuel filters.
Yes ____
No ____
EXHAUST SYSTEM
The exhaust system shall be installed under the frame with the discharge 90 degrees to the
right side forward of the rear tires.
System joints shall be connected with lapping band clamps.
Yes ____
No ____
AIR CLEANER
The air cleaner shall be a dry type with a replaceable element, it shall have an outside air intake
with an ember separator filter and an indicator light in the warning light cluster to show when the
air cleaner element requires replacement.
Yes ____
RFQ (Goods and Services) No.: 1220-41-25-09
No ____
31
COOLING SYSTEM
The cooling system shall have sufficient capacity to keep the engine properly cooled under all
conditions of road and pumping operations. The cooling system shall be designed and tested to
meet or exceed the engine and transmission manufacturer and EPA requirements. The
complete cooling system shall be mounted in a manner to isolate the system from vibration and
stress. The individual cores shall be mounted in a manner to allow expansion and contraction
at various rates without inducing stress into the adjoining core.
Radiator
The radiator shall be a cross-flow design constructed completely of aluminum with welded side
tanks. The radiator shall have a minimum of a 571 sq. in. core. The radiator shall also be
equipped with a drain cock to drain the coolant for serviceability.
Surge Tank
The cooling system shall be equipped with a surge tank that is capable of being filled and
removing entrained air from the system. The surge tank shall be equipped with a low coolant
probe and sight glass to monitor the level of the coolant. The surge tank shall have a cap that
meets the engine manufactures pressure requirements as well as the system design
requirements.
Overflow Tank
Cooling system requires an overflow tank to catch any expelled coolant.
Coolant
The cooling package shall have Extended Life Coolant (ELC) installed.
The use of
supplemental coolant additives (SCA) will not be allowed, as this is part of the extended life
coolant makeup. The coolant shall contain ethylene glycol and deionized water to keep the
coolant from freezing to a temperature of -34 degrees F.
Hoses/Clamps - Radiator
All radiator tubes shall be formed from aluminized steel tubing and installed with silicone hoses
with stainless steel constant torque clamps.
Recirculation Shields
Recirculation shields shall be installed where required to prevent heated air from reentering the
cooling package and affecting the performance
Hoses/Clamps - Charge Air Cooler
All charge air cooler tubes shall be formed from aluminized steel tubing and installed with
silicone hump hoses and stainless steel "T" style clamps meeting the engine manufactures
requirements.
Yes ____
No ____
COOLING SYSTEM FAN
The engine cooling system shall incorporate a heavy-duty composite fan, belt driven on the
engine. A shroud and recirculation shield system shall be used to ensure air that has passed
through the radiator is not drawn through it again.
Yes ____
RFQ (Goods and Services) No.: 1220-41-25-09
No ____
32
TRANSMISSION COOLING SYSTEM
Transmission Cooler
Prefer the transmission cooler to be a cross flow air to oil design constructed completely of
aluminum with welded side tanks. The transmission cooler shall have a minimum of a 136
square inch core and shall be bolted to the bottom of the radiator to allow a single depth core,
allowing a more efficient and serviceable cooling system. The transmission cooler shall be
mounted in such a manner as not to extend below the chassis frame by more than 1", allowing
greater approach angles and ground clearance.
For retarder applications, additional oil to water tube bundle cooler shall be installed. The cooler
will be installed into the retarder circuit providing cooling for the retarder. The tube bundle
cooler shall be mounted to the chassis, plumbed into the engine cooling system plumbing.
Yes ____
No ____
COOLANT FILTER
An engine coolant filter with a shut-off valve shall be installed on the engine. The location of the
filter shall allow for easy maintenance.
Yes ____
No ____
TRANSMISSION
The transmission shall be an Allison 4000 EVSPR automatic with electronic controls and an
output retarder modulated by 1/3 throttle and 2/3 brake pedal actuation. The transmission shall
have two (2) 10-bolt PTO pads.
The transmission shall be equipped with an air to oil transmission cooler located below the
radiator allowing a single depth core and efficient cooling package. The transmission cooler
shall be mounted in a manner to allow maximum approach angle by not protruding below the
frame more than an inch. The transmission cooler shall be constructed of aluminum with
welded side tanks. An external transmission cooler shall also be plumbed into the system to
provide retarder-cooling capacity. The transmission shall have two (2) internal oil filters.
Fourth gear hold-in range may be accomplished by wiring for a pumping application.
Yes ____
No ____
SYNTHETIC TRANSMISSION FLUID
Castrol "Transynd" or an equivalent synthetic TES 295 transmission fluid shall be utilized to fill
the EVS transmission.
Yes ____
No ____
TRANSMISSION TOUCH PAD
An Allison pressure sensitive range selector touch pad shall be provided and located to the right
of the driver within clear view and reach.
Yes ____
No ____
TRANSMISSION MODE
The transmission, upon start-up, will select four- (4) speed operation. By pressing the "mode"
switch on the shift pad (mode on) provides five- (5) speed overdrive.
Yes ____
No ____
DRIVELINES
All drivelines shall be Spicer 1810 heavy duty series with "glide coat" splines on all slip shafts.
Yes ____
RFQ (Goods and Services) No.: 1220-41-25-09
No ____
33
STOP, TAIL, TURN AND BACK-UP LIGHT WIRING
Individual wires shall be run to the rear of the chassis for the stoplight, turn signal, taillight and
back-up lights.
Yes ____
No ____
MULTIPLEX ELECTRICAL SYSTEM WITH COLOR DISPLAY
Prefer; a Weldon multiplex electrical system to be supplied. The system shall be a single
starting type, installed per NFPA 1901. The electrical system shall be 12 volt, suppressed per
SAE J551, prefer six (6) Group 31 950 CCA batteries with 210 minute reserve capacity and 3/0
welding type dual path starter cables per SAE J541.
The Multiplexed wiring system shall include the following:
* Dash mounted information center with approximately 4"H (92mm) x approximately 6"W
(159mm) color LCD screen.
* Systems Diagnostic Menu and controls.
* Solid state switching.
* Complete Peer-to-Peer network architecture.
* Weatherproof Nodes and sealed Deutsch connectors.
* Sequences and sheds electrical loads.
The Vista III Display Node shall include the following features:
* Automatic climate control.
* Outside temperature display.
* A real time clock with display.
* Three (3) programmable video inputs.
* A useable temperature range from -40 degrees to 185 degrees F.
* Unlimited virtual switches.
* Selectable font sizes, types and colors for optimum user efficiency.
* Selectable color buttons and screen backgrounds.
All wiring to be appropriate gauge cross-link with 311-degree F. insulation. All wires in the
chassis shall be circuit numbered and function coded, in addition the SAE wiring will be color
coded. The wiring shall be protected by 275 degree F. minimum high temperature flame
retardant loom as required.
Features included with the Multiplex system include:
Back-up Alarm Disable Switch
A back-up alarm disable switch shall be installed in the cab dash within reach of the driver. The
switch will allow the driver to turn the back-up alarm off. The back-up alarm shall automatically
reset to sound the next time the transmission is placed in reverse.
Incandescent Ground Lighting Below Each Door
The cab shall be equipped with Trucklite model #40003 sealed bulb, incandescent lighting
under each cab door. The lights will be activated by either a single switch on the dash or each
respective door switch.
Alternating Headlights
An alternating high beam headlamp flashing system shall be installed into the high beam
headlamp system that will allow the high beams to flash alternately from left to right.
The completed system shall be capable of using high beam to override flashing function and will
flash high beams only when the low beam headlamps are selected.
RFQ (Goods and Services) No.: 1220-41-25-09
34
Audible Alarm for Open Door Light
An audible alarm shall be wired to the open door light, which will sound when a door is open
and the air brake is off with the vehicle in gear.
Yes ____
No ____
INSTRUMENTATION -STANDARD WITH METRIC SPEEDOMETER
The instrument panel shall contain the following gauges:
One (1) electronic tachometer with integral digital hour meter. The scale on the tachometer
shall read from 0 to 3000 RPM. The hourmeter shall display engine hours of operation.
One (1) electronic speedometer with integral digital odometer. The speedometer shall have a
dual scale with kilometers per hour (KPH) as the dominant scale and miles per hour (MPH) on
the minor scale. The speedometer scale shall read from 5 to 135 KPH (10 to 80 MPH). The
odometer shall display kilometers.
One (1) three function gauge with primary air pressure, secondary air pressure and fuel level.
The scale on the air pressure gauges shall read from 0 to 140 pounds per square inch (PSI).
The air pressure scales shall be non-linear to expand the scales in the region of normal
operation. The scale on the fuel level gauge shall read from empty to full.
One (1) four function gauge with engine oil pressure, coolant temperature, transmission oil
temperature and a voltmeter. The scale on the engine oil pressure gauge shall read from 0 to
140 pounds per square inch (PSI). The engine oil pressure scale shall be non-linear expand the
scale in the region of normal operation. The scale on the coolant temperature gauge shall read
from 100 to 250 degrees Fahrenheit (F). The scale on the transmission oil temperature gauge
shall read from 100 to 300 degrees Fahrenheit (F). The scale on the voltmeter shall read from 8
to 16 volts.
One (1) brake application gauge measured in PSI.
The instrument panel shall contain an Annunciator Module that contains the following indicator
lights. All indicator lights shall contain LED lamps.
Yes ____
No ____
Yes ____
No ____
RED LAMPS
Stop Engine - indicates critical engine fault.
Park Brake - indicates park brake is set.
Low Fuel - indicates low fuel.
Cab Ajar - indicates tilt cab is not locked down.
Volts - indicates high or low system voltage.
Low Oil Press - indicates low engine oil pressure.
High Coolant Temp - indicates excessive engine coolant temperature.
High Trans Temp - indicates excessive transmission oil temperature.
Low Air - indicates low air pressure in either system one or system two.
Low Coolant Level - indicates low engine coolant level.
Low Oil Level - indicates low engine oil level.
Air Filter - indicates excessive engine air intake restriction.
RFQ (Goods and Services) No.: 1220-41-25-09
35
YELLOW LAMPS
Check Engine - indicates non-critical engine fault.
Check Trans - indicates transmission fault.
ABS - indicates anti-lock brake system fault.
Water in Fuel - indicates presence of water in fuel filter.
Engine Maint - indicates engine maintenance is required.
Yes ____
No ____
GREEN LAMPS
Left and Right turn signal indicators.
Aux Brake Active - indicates secondary braking device is active.
High Idle - indicates engine high idle is active.
Low Trac - indicates low wheel traction for automatic traction control (ATC) equipped vehicles,
also indicates mud/snow mode is active for ATC system.
Yes ____
No ____
BLUE LAMP
High beam indicator.
The instrumentation system shall provide a constant audible alarm for the following situations:
Low air pressure.
Low engine oil pressure.
High engine coolant temperature.
High transmission oil temperature.
Low coolant level.
High or low system voltage
Critical engine fault (Stop Engine).
The instrumentation system will provide a three second alarm every three minutes for the
following situations:
Low fuel
Water in fuel
Yes ____
No ____
Yes ____
No ____
STARTING SYSTEM PANEL
Prefer the starting system to be supplied with the following:
One (1) master battery switch.
One (1) ignition switch.
One (1) starter button.
One (1) green LED indicator for battery "on".
One (1) green LED indicator for ignition "on"
ROCKER SWITCH CONSOLE
A three (3) section, double row switch console shall be provided with easy switch access to both
the driver and officer. The console will consist of an angled driver's side panel, center main and
angled officer's side panel.
Yes ____
RFQ (Goods and Services) No.: 1220-41-25-09
No ____
36
OFFICER ROCKER SWITCH PANEL
The officer's side switch panel shall include two (2) momentary switches. One (1) shall operate
the Federal Q2B siren, and one (1) shall operate the air horns.
Yes ____
No ____
CENTER ROCKER SWITCH PANEL
The center main rocker switch panel shall include six (6) LED backlit and labeled rocker
switches mounted in the left hand side of the panel. The single row of switches shall be located
across the top left of the panel. The right hand section of the panel shall be left free to
accommodate flush mounted equipment.
From left to right: Chains, Horn, PTO, Spare, Spare, Siren brake.
Yes ____
No ____
DRIVER ROCKER SWITCH PANEL
The color Mux Vista display will be mounted in the right hand side of the panel. The driver's
side panel shall include a rocker type headlight switch with instrument lamp slide dimmer,
intermittent windshield wiper/washer switch, secondary braking device rocker switch.
Yes ____
No ____
POWER AND GROUND STUDS - BATTERY DIRECT
Power and grounding studs shall be provided and installed behind the electrical center cover
with a breaker. The studs shall be #10 and capable of carrying up to a 40 amp battery direct
load.
The power and ground studs are to have two (2) switched on with ignition and two (2) battery
direct (hot).
Yes ____
No ____
ALTERNATOR
A 270 amp Leece Neville 12 volt alternator with integral regulator and #10 screw AC terminals
shall be installed.
Yes ____
No ____
KUSSMAUL 20 AMP INLET
A Kussmaul 20 amp electrical receptacle with a gray weatherproof cover and box.
This shorepower inlet is to be located in the driver's step area.
Yes ____
No ____
BATTERY CONDITIONER 1200 KUSSMAUL
A Kussmaul 1200 battery conditioner shall be supplied.
The battery conditioner shall be mounted in the cab behind the driver's seat.
The remote charge indicator display will be located and viewable through the driver's side
center cab window.
Yes ____
No ____
BATTERY JUMPER STUDS
Battery jumper studs shall be provided in the driver's step area. The studs allow the vehicle to
be jump-started or cab to be raised in an emergency due to battery failure.
Yes ____
RFQ (Goods and Services) No.: 1220-41-25-09
No ____
37
PUMP PANEL HARNESS MID MOUNT
An apparatus interface wiring harness for the engine will be supplied with the chassis. The
harness shall have a connector to connect to the chassis harness drop out at the back of the
cab. The harness shall be for a mid-mount pump panel. The harness shall contain circuits for a
Class 1 TPG and 3 in 1 gauge connector multiplexed gauge connector which includes
tachometer, engine temperature and engine oil pressure. Separate circuits are also included for
engine oil pressure warning light, engine coolant temperature warning light, low fuel light, check
engine light, stop engine light, high idle switch and high idle indicator light.
Yes ____
No ____
MARKER LAMPS
Five (5) I.C.C. DOT approved Light Emitting Diode (LED) cab marker lamps shall be installed on
the face of the cab above the windshield.
Yes ____
No ____
BACKUP ALARM
A backup alarm shall be installed at the rear of the chassis with an auto-adjusting output level of
not less than 87 dB and up to 107 dB. The alarm will automatically activate when the
transmission is placed in reverse.
Yes ____
No ____
RED WARNING LIGHTS IN CAB DOORS
Four (4) red 4" diameter LED Trucklite flashing warning lights shall be provided on the inner
surface of each cab door to serve as an indicator to oncoming traffic that the cab door is open.
Or Surrey approved equal.
Yes ____
No ____
SCENE LIGHTS
Two (2) Whelen #810 Series clear halogen scene lights shall be installed on the sides of the
cab. The lights shall be surface mounted one (1) each side of the cab. The lights shall be
controlled by opening the cab doors and by separate switches one (1) for the left side and one
(1) for the right side.
Yes ____
No ____
HEADLIGHTS
Four (4) rectangular halogen headlamps with a separate high and low beams in bright bezels
shall be provided. The headlamps shall be equipped with a "Daytime Running" light feature,
which will illuminate the headlights to 80% brilliance when the master switch is in the "On"
position and the parking brake is released.
Yes ____
No ____
WARNING LIGHTS -INBOARD
Four (4) Whelen 4x6 SUPER LED red warning lights shall be installed on the cab fascia above
the headlamps in a chrome housing.
Yes ____
RFQ (Goods and Services) No.: 1220-41-25-09
No ____
38
TURN SIGNALS - AMBER LED
Two (2) Whelen 4x6 amber LED programmable turn signals shall be installed in polished
aluminum castings above the outer warning lamps.
Two (2) round side turn signal/marker lights shall be provided on the front cab corners.
Yes ____
No ____
FLAT FLOOR 10" RAISED ROOF 4DR TILT CAB
The cab shall be a Flat Floor (medium four door), 10" raised roof, aluminum tilt cab, capable of
seating six (6) firefighters.
Prefer the raised roof to extend from the back of the cab to the center of the front doors to
provide additional headroom for the driver and officer.
The cab shall be of the Eurospace interior design allowing for easy communication inside the
cab. The cab overall length shall be approximately 130.38" with 54.00" from the centerline of
the front axle to the back of the cab.
All glass used in the cab shall be automotive tint.
A grab handle shall be provided on the hinge post inside the cab at both the driver and officer
door for entering and exiting the cab.
Intermittent electric wipers with a single motor and electric powered "wet arm" type windshield
washers shall be provided.
Yes ____
No ____
CAB DOORS
All doors shall be equipped with black exterior pull handles, suitable for use with firefighter
gloves, and keyed alike locks that are designed to prevent accidental lockout.
Step area to have aluminum checker kick plates
State Door and Step Measurements
Front Entry Doors:
Front Entry Steps:
Rear Entry Doors:
Rear Entry Steps:
Yes ____
No ____
Yes ____
No ____
FRONT AND REAR ROLL DOWN DOOR WINDOWS
The front and rear doors shall have a full roll down window.
INNER DOOR PANELS ZOLATONE PAINTED
The inner door panels shall be a Zolatone painted aluminum panel. A "Fireman Friendly" cast
steel pull handle shall be included with the front door panel.
Yes ____
RFQ (Goods and Services) No.: 1220-41-25-09
No ____
39
DOOR WARNING - CHEVRON
Four (4) Chevron reflective signs shall be installed on the lowest portion of the inner door
panels, one (1) on each door. A stripe of reflective tape shall be installed at the outer edge of
each door.
Yes ____
No ____
REINFORCEMENT FOR ROOF MOUNTED SCENE LIGHT
The scene light will be a Comandlight Shadow-RT #SL445-RT mounted to the upper raised roof
of the cab. The actual final location must be indicated by the Fire Department prior to ordering
the cab.
Yes ____
No ____
ENGINE COVER
The fixed type engine cover shall be a maximum of 21.00" high x 36.00" wide. The cover shall
be an integral part of the cab and made of 0.19" thick aluminum.
The interior cab side shall be covered with a multi-layer mat consisting of; .25" thick sound
absorbing closed-cell foam, a heavy weight sound barrier, a .06" thick non-slip vinyl wear
surface with a pebble grain finish, and held in place by a pressure sensitive adhesive and
aluminum cornering trim. All exposed seams are sealed to reduce moisture contamination and
debris build up.
The engine side of the cover shall be heavily insulated with multi-layer insulating materials,
consisting of foam, a 1.0 lbs per sq ft sound barrier with a facing that resists heat transfer, and
held in place by adhesive, aluminum stick pins and retention caps. All exposed insulation
seams and edges are sealed to reduce moisture contamination and debris build up.
Yes ____
No ____
ENGINE COVER TOP
If the engine cover is sloped, then an aluminum top is required to level the engine cover surface.
This top is to be Line-x type coated in black
Yes ____
No ____
FULL WIDTH CREW CAB DOOR ASSIST RAILS
Black powder coated cast aluminum assist rails shall be provided and installed on the inside of
the rear crew doors the full width of the window glass. The rails shall assist personnel in exiting
and entering the cab. The rails shall be located at the retracted door window glass level and will
protect the exposed window glass area.
Yes ____
No ____
MOBILE DATA TERMINAL PROVISION W/GLOVE COMPARTMENT - XTREME DUTY TYPE
The cab interior dash trim officer panel shall consist of a high impact resistant “Zolatone type”
painted aluminum module, which contains a glove compartment with a hinged non-locking door.
A Mobile Data Terminal (MDT) provision shall be provided above the glove compartment.
Yes ____
No ____
INTERIOR LIGHTING
The cab interior lighting shall consist of the following:
A red/white dome lamp shall be located over each door. The white lamp shall be activated by its
respective door when opened and both activated by an individual switch on the light.
RFQ (Goods and Services) No.: 1220-41-25-09
40
A red/white dome lamp with individual switches shall be located in the headliner, over the
engine tunnel to serve as a tunnel surface light.
Yes ____
No ____
FLASHING DOOR AJAR LIGHT
A red flashing door ajar light shall be located in the headliner, centered in the cab. The light
shall be approximately 6.00" long x 2.50" wide x 1.75" high and labeled "Do Not Move
Apparatus". The light shall be wired to indicate an open door on the cab when the parking
brake is released.
Yes ____
No ____
ENGINE TUNNEL LIGHT
A clear work light shall be provided and installed under the engine tunnel. A 4” round Trucklite
preferred.
Yes ____
No ____
MAP LIGHT
A Sunnex instrument panel map light shall be installed on the right hand side (Officer’s side) of
the overhead HVAC consul.
Yes ____
HAND HELD SPOTLIGHT
A Collins Pulsar 500 hand-held spotlight shall be sent loose.
momentary switch and a 500,000 candlepower lamp.
No ____
It shall have a coil-cord, a
Yes ____
No ____
Yes ____
No ____
Yes ____
No ____
VINYL COVERED SEATS
The seats shall be covered with a vinyl material.
BLACK SEAT COLOR
All seats supplied on the chassis shall be black in color.
DRIVER SEAT
The driver's seat shall be an H.O. Bostrom Sierra, non SCBA, high back seat and shall include
a tapered and padded seat cushion and back with air ride suspension.
The seat shall have red three-point shoulder harness with lap belt and an automatic retractor.
Cab front underseat access door to be painted.
Yes ____
No ____
OFFICER SEAT
The officer's seat shall be a four-way air suspended type H.O. Bostrom Sierra SCBA high back
seat with air control valve located at lower front of seat. The suspension mechanism shall be
enclosed by a rubber bellows.
The seat back shall include a spring loaded flip-up headrest with Secure-All SCBA brackets. A
removable padded cover shall be supplied over the SCBA cavity.
The seat shall be equipped with a red three-point shoulder harness with lap belt and an
automatic retractor attached to the cab.
Cab front underseat access door to be painted.
Yes ____
RFQ (Goods and Services) No.: 1220-41-25-09
No ____
41
REAR FACING OUTBOARD SEATS
Two (2) outboard rear facing crew area H.O. Bostrom Tanker 400 SCBA individual seats shall
be installed in the rear of the cab.
Each seat shall include a tapered and padded seat cushion and back with a spring loaded
hinged fold up seat bottom.
Each seat back shall include a spring loaded flip-up headrest with Secure-All SCBA brackets. A
removable vinyl cover shall be supplied over the SCBA cavity.
Prefer the seats to be an ABTS (All Belts to Seat) type integrated red three-point shoulder
harness with lap belt and an automatic retractor built into the seat assembly.
Yes ____
No ____
FORWARD FACING CENTER SEATS
Two (2) center forward facing crew area H.O. Bostrom Sierra high back individual seats shall be
installed in the rear of the cab.
Each seat shall include a tapered and padded seat cushion and back with a spring loaded
hinged fold up seat bottom.
Prefer the seats to be an ABTS (All Belts to Seat) type integrated red three-point shoulder
harness with lap belt and an automatic retractor built into the seat assembly.
Seats are to be separated as far apart as possible for additional shoulder room.
Yes ____
No ____
FORWARD FACING CENTER SEAT BOX
A seat box 42-3/8" wide x 12" high x 22" deep shall be installed against the center of the rear
wall for seat mounting. The seat box shall be made from smooth aluminum and welded to the
cab structure for seat mounting integrity. The seat box will be painted the cab interior color.
Both sides of the seat box shall have a hinged door with latch and opening 13-3/4" wide x 10"
high to allow access for storage in the seat box.
Yes ____
No ____
PAINT INTERIOR
The interior metal surfaces shall be painted with a “Zolatone type” black/gray texture finish.
Yes ____
No ____
PAINT INNER DOOR PANELS
The inner door panel surfaces shall be painted with a “Zolatone type” black/gray texture finish.
Yes ____
No ____
DASH AND HEADER TRIM XTREME DUTY TYPE
The cab interior dash trim shall consist of a two (2) piece vacuum formed ABS composite driver
(or Xtreme Duty if available), a high impact aluminum officer panel and a high impact aluminum
center assembly. The center dash shall incorporate the integral rocker switch console and
incorporate a latching electrical component access cover to allow complete access to the
underside of the switch panel assembly and electrical harness and components.
The "A" pillar and center windshield post trim shall consist of a vacuum formed ABS composite
driver, officer and center cover.
RFQ (Goods and Services) No.: 1220-41-25-09
42
The header trim shall consist of a vacuum formed ABS composite driver, officer and a two (2)
piece center HVAC cover. Mounted to the trim panels shall be two (2) vinyl sunvisors.
Yes ____
No ____
INTERIOR TRIM COLOR AND FLOOR MAT GRAY/GRAY/BLACK
The cab interior soft vinyl trim surfaces shall be gray in color.
The cab interior vacuum formed ABS composite trim surfaces shall be gray in color.
The cab interior floormat shall be black in color.
The interior cab floor, engine tunnel sides and front seat risers shall be covered with a mutlitlayer mat consisting of; .25" thick sound absorbing closed-cell foam, a heavy weight sound
barrier, a .06" thick non-slip vinyl wear surface with a pebble grain finish, and held in place by a
pressure sensitive adhesive and aluminum cornering trim. All exposed seams are sealed to
reduce moisture contamination and debris build up.
Yes ____
No ____
HVAC SYSTEM
The cab shall be equipped with a ceiling mounted HVAC system. The system shall consist of
an overhead heater/defroster/air-conditioning unit mounted above the engine tunnel in a central
location with dash mounted controls.
The ceiling mounted HVAC system shall include adjustable louvers. Forward facing louvers for
windshield defrosting, rearward facing louvers to direct air for crew, driver and officer comfort.
In "Cabin Mode" the system is designed to produce 60,000 Btu's of heat and 32,000 Btu's of
cooling. The system shall be capable of lowering the cab interior temperature from 100 degrees
to 70 degrees within thirty minutes, with a relative humidity of sixty percent.
A roof mounted condenser shall be installed.
The air-conditioning compressor will be an engine driven and utilize R-134A refrigerant.
The A/C lines will be a mixture of custom bent zinc coated steel fittings and Aeroquip flexible
hose with E-Z clip fittings.
All heater system hoses, including auxiliary units shall be silicone with stainless steel constant
torque clamps approved for use with silicone hose.
Yes ____
No ____
AUXILLARY DEFROSTER FANS
Four (4) electric defroster fans, two (2) are to be mounted at the top of the windshield, one (1)
each side, two (2) are to be mounted in the rear of the cab. Exact location to be determined at
pre-construction meeting. They are to be switched at the fan.
Yes ____
No ____
DELUXE INSULATION PACKAGE
Additional insulation in the cab shall be installed to improve air-conditioning and/or heating in
extreme weather climates as well as reducing road noise. The sides, roof and rear wall of the
cab shall contain 1" thick multilayered insulation.
Yes ____
No ____
CAB TILT ACTUATION
The entire cab shall tilt 45 degrees to allow for easy maintenance of the engine and
transmission.
RFQ (Goods and Services) No.: 1220-41-25-09
43
The cab tilt actuation shall be with an electric over hydraulic lift pump with a control box on a
pendant for safe visual operation.
The lift system shall have an ignition interlock and red lock down indicator lamp, which shall
illuminate when holding "down" switch to indicate safe road operation. It shall be necessary to
activate the master battery switch with the park brake set in order to tilt the cab.
Two cab tilt cylinders shall be provided with velocity fuses in each cylinder port.
Two spring loaded hydraulic hold down hooks outboard of the frame shall be installed for
holding the cab securely to the frame.
A steel safety assembly shall be installed on the cab lift cylinder to prevent accidental cab
lowering. The safety assembly shall fall over the lift cylinder when the cab is in the "up" position.
A cable release system shall also be provided to clear the safety assembly from the lift cylinder
when lowering the cab.
Yes ____
No ____
MANUAL CAB LIFT PUMP - HORIZONTAL
A manual cab lift pump module shall be attached to the electric over hydraulic tilt pump. The
hand pump shall be mounted in a horizontal orientation.
Yes ____
No ____
POLISHED STAINLESS STEEL ON REAR CAB CORNERS
The rear corners of the cab shall be trimmed with polished stainless steel to protect the cab
paint.
Yes ____
No ____
WHEEL WELL LINERS
Full width wheel well liners shall be installed on the extruded cab to limit road splash and enable
easier cleaning. The two-piece liners shall consist of an inner liner 16" wide made of vacuum
formed ABS composite and a outer fenderette 3.50" wide made of 14 gauge 304 polished
stainless steel.
Yes ____
No ____
FRONT GRILLE
A two (2) piece, hinged stainless steel raised front grille 39"W x 33.50"H x 1.50"D, with a
minimum free air intake of 632.9 square inches shall be installed on the front of the cab. The
upper portion of the grille will be hinged and will have two (2) flush push button latches that
allow access to the front fluid fills of the cab.
Yes ____
No ____
CAB WINDOWS
Fixed cab side windows shall be installed behind the front cab doors one each side of the cab.
Each window shall be the same height as the windshield to provide maximum visibility.
Yes ____
No ____
REAR CAB WINDOWS
The cab shall have two (2) fixed windows, 8”W x 26”H, at the outer edges on the rear wall
mounted in black anodized aluminum frames with lower drain slots.
Yes ____
RFQ (Goods and Services) No.: 1220-41-25-09
No ____
44
DARK TINTED WINDOWS
A 45% light transmittance dark tint shall be applied to windows to aid in cab cooling and to help
protect passengers from radiant solar energy.
Windows are to include the following:
Driver's side center window.
Driver's side rear crew window.
Driver's side rear wall window.
Officer's side center window.
Officer's side rear crew window.
Officer's side rear wall window.
Do not dark tint driver’s and officer’s front roll down windows.
Yes ____
No ____
EXTERIOR CAB ASSIST HANDLES
Four (4) anti-slip one-piece exterior assist handles shall be installed, one (1) behind each cab
door. The assist handle shall be made of 14 gauge 304 stainless steel and be 1.25" diameter to
enable easy grabbing with the gloved hand.
Yes ____
No ____
CAB MIRRORS
Two (2) Retrac, West Coast style mirrors model 1171HL shall be provided. The mirrors shall be
Single Vision, motorized and heated with a flat 7" x 16" head and 8" round lower convex. The
mirror heads shall be mounted on stainless steel bow swing away type arms mounted to the cab
doors. The mirrors shall be heated and lighted by amber clearance lights, or Surrey approved
equal.
Yes ____
No ____
TWO TONE PAINT
The cab shall be painted two tone with a finished break line 1.5" below the cab side windows
and down to the top of the grill on the cab front fascia.
All cab painting must be completed prior to the installation of glass accessories or any other cab
trim to assure complete paint coverage and maximum corrosion protection.
A .5" (1/2") gold reflective tape with black borders shall be applied on the break line between the
two different colored surfaces.
Preferred brand of paint, upper color and lower color:
PPG FBCH System
Upper: 2185 WHITE
Lower: 75390 ALT RED
Yes ____
No ____
OPERATORS MANUAL AND PARTS LIST
A chassis operator's manual and parts list with wiring and air plumbing diagrams shall be
provided. The wiring and plumbing diagrams shall be of the chassis model.
Yes ____
No ____
ENGINE AND TRANSMISSION OPERATION MANUAL
One (1) engine operation and maintenance manual and one (1) transmission operation manual
shall be included in the Spartan operator's manual.
Yes ____
RFQ (Goods and Services) No.: 1220-41-25-09
No ____
45
AS BUILT DIAGRAMS
"As built" wiring diagrams shall be supplied for the chassis model provided.
Yes ____
No ____
CHASSIS FAMILIARIZATION CLASS
Chassis Familiarization Class will cover complete chassis maintenance from bumper to bumper
at your facility. The class will outline general operation of the cab/chassis system/components
operationally as well. The class concludes with the sharing of technical information on CD and
time for questions and answers.
Yes ____
No ____
INDEPENDENT FIRE PUMP MOUNTING
The fire pump will be mounted within a separate body module that is not directly connected to
the apparatus body. The module will be mounted to the frame in four locations and in such a
manner that should the apparatus be involved in a collision, the likelihood the pump casing
cracking is minimized.
The point where the pump module is mounted to the frame will be reinforced appropriately to
carry the expected load for the life of the apparatus.
Plumbing as well as the pump will be integral with the pump module as much as possible to
facilitate the changing of the chassis should the apparatus be involved in a collision.
Yes ____
No ____
MIDSHIP MOUNTED FIRE PUMP
The fire pump will be a Hale model Qmax 2250 midship mounted unit, rated at 2250 U.S.
gallons per minute.
Yes ____
No ____
SINGLE STAGE FIRE PUMP
The pump will be a single stage centrifugal class "A" rated fire pump, designed specifically for
the fire service.
The entire pump will be assembled and tested at the pump manufacturer's factory.
The pump will be driven by a driveline from the truck transmission. The engine will provide
sufficient horsepower and RPM to enable the pump to meet and exceed its rated performance.
Yes ____
No ____
ULC PUMP CERTIFICATION
The fire pump will be tested and certified by Underwriters Laboratories of Canada, to perform as
listed below:


100% of rated capacity at 1000 kPa net pressure.

70% of rated capacity at 1350 kPa net pressure.

50% of rated capacity at 1700 kPa net pressure.
The entire pump, both suction and discharge passages, will be hydrostatically tested to a
pressure of 600 PSI.
The pump will comply with the applicable requirements of "Standard for Automotive Fire
Fighting Apparatus" CAN/ULC-S515, latest revision.
The pump will be free from objectionable pulsation under all normal operating conditions.
The pump is to be certified to 7,000 litres.

Yes ____
RFQ (Goods and Services) No.: 1220-41-25-09
No ____
46
PUMP BODY
The pump body and related parts will be of fine grain alloy cast iron, with a minimum tensile
strength of 30,000 PSI. All moving parts in contact with water will be of high quality bronze or
stainless steel. Pumps utilizing castings made of lower tensile strength cast iron are not
acceptable.
The pump body will be split, on a single plane in two sections for easy removal of the entire
impeller assembly, including wear rings and bearings from beneath the pump, without disturbing
piping or the mounting of the pump.
The pump will have one (1) double suction impeller. The pump body will have two (2) opposed
discharge volute cutwaters to eliminate radial unbalance.
The pump shaft will be rigidly supported by three bearings for minimum deflection. One high
lead bronze sleeve bearing will be located immediately adjacent to the impeller. The sleeve
bearing will be lubricated by a force-fed, automatic oil lubricated design, pressure balanced to
exclude foreign material. The remaining bearings will be heavy-duty, deep groove ball bearings
in the gearbox and they will be splash lubricated.
Yes ____
No ____
MECHANICAL SEAL
The pump will be equipped with a mechanical seal. Only one (1) will be required and it will be
located on the suction (inboard) side of the pump. The mechanical seal will be two (2) inches in
diameter and will be spring loaded, maintenance free and self-adjusting. Mechanical seal
construction will consist of a carbon sealing ring, stainless steel coil spring, Viton® rubber cup,
and a carbide seat with Teflon® backup seal.
Yes ____
No ____
PUMP GEARBOX
The gearbox will be assembled and tested at the pump manufacturer factory.
Pump gearbox will be of sufficient size to withstand up to 16,000 ft lbs of torque in road
operating conditions. The drive unit will be designed of ample capacity for lubrication reserve
and to maintain the proper operating temperature.
The gearbox drive shafts will be of heat-treated chrome nickel steel and at least 2-3/4 inches in
diameter, on both the input and output drive shafts. They will withstand the full torque of the
engine.
All pump drive gears will be of highest quality electric furnace chrome nickel steel. Bores will be
ground to size and teeth integrated, shaved, hardened and ground to give an extremely
accurate gear for long life, smooth quiet running, and higher load carrying capability. An
accurately cut spur design will be provided to eliminate all possible end thrust.
The pump ratio will be selected by the apparatus manufacturer to give maximum performance
with the engine and transmission selected.
Yes ____
No ____
HALE ANODES
There will be two (2) Hale zinc anodes provided with the fire pump. The anodes will aid in
preventing galvanic corrosion within the water pump. The anodes will be installed in the suction
manifold of the pump and will easily replaceable.
Yes ____
RFQ (Goods and Services) No.: 1220-41-25-09
No ____
47
AIR OPERATED PUMP SHIFT
The pump shift actuating mechanism will be air operated from a valve in the cab identified as
"PUMP SHIFT". Full instructions for shifting the pump will be inscribed on the valve plate.
Yes ____
No ____
MANUAL OVERRIDE PUMP SHIFT
A manual override system will be supplied for the pump shift should a problem develop in the
chassis air brake system.
Yes ____
No ____
PUMP SHIFT INDICATING LIGHTS
There will be two (2) green pump system shift indicator lights in the chassis cab. The first light
will become energized when the pump has completed its shift into pump gear and will be
labeled "Pump Engaged". The second light will become energized when the chassis parking
brake has been set, and when the pump and the chassis transmissions have been shifted
completely into the correct gears for pumping, this light will be labeled "OK to Pump".
There will be one (1) green pump system shift indicator light located on the operator's panel.
This light will only become engaged when the chassis parking brake has been set, and when
the pump and the chassis transmissions have been completely shifted into the correct gears.
The light will be located adjacent to the throttle control and will be labeled "Warning: Do Not
Open Throttle Unless Light Is On".
Yes ____
No ____
PRIMING PUMP CONTROL
The Priming Pump will be controlled at the pump operator's panel. The control will be provided
in the form of a push-pull "T" handle that is easily actuated with a gloved hand.
When the handle is in the "engaged" position, the indicator light at the pump panel will illuminate
to notify the operator.
Yes ____
No ____
HALE ESP PRIMER
The priming pump will be a Hale model ESP, environmentally safe priming system. The pump
will be a positive displacement, rotary vane type unit that is self-lubricating, thereby requiring no
oil that could leak onto the ground. The pump will be controlled from the pump operator's panel.
An indicator light on the pump panel will show when the primer motor is engaged. The pump
will be capable of creating suction and discharging water from a lift of 10 feet through 20 feet of
suction hose of the appropriate size, in not more than 30 seconds starting with the pump dry. It
will be capable of developing a vacuum of 22 inches at an altitude of up to 1000 feet.
Yes ____
No ____
TOTAL PRESSURE GOVERNOR (TPG)
Apparatus shall be equipped with a Class 1 “Total Pressure Governor” (TPG) that is connected
to the Electronic Control Module (ECM) mounted on the engine.
The “TPG” will operate as a pressure sensor (regulating) governor (PSG) utilizing the engine’s
J1939 datalink for optimal resolution and response provided that J1939 is supported by the
engine manufacturer. If J-1939 engine control is not supported, then analog remote throttle
control shall be provided by the TPG, subject to J1939 RPM data availability.
The TPG shall utilize control algorithms that minimize pressure spikes during low or erratic
water supply situations and display operational status messages to the operator under certain
circumstances.
RFQ (Goods and Services) No.: 1220-41-25-09
48
The TPG shall be backwards compatible to any engine that supplies J1939 RPM, Temperature
and Oil Pressure information providing the ability to maintain consistent fleet fire-fighting
capability.
TPG shall incorporate the ability to use either a 300 PSI or a 600 PSI transducer for best
operation.
PSG system diagnostics shall be built in and accessible by service technicians. Programmable
presets for RPM and Pressure settings shall be easily configurable.
The TPG shall incorporate configurable parameters in the menu structure accessed through a
diagnostic password.
The “TPG” shall also include indication of engine RPM, system voltage, engine oil pressure and
engine temperature complete with audible alarm output for all.
The “TPG” uses the J1939 data bus for engine information, requiring no additional sensors to be
installed.
The TPG shall use J1939 broadcast warnings for the alarm points as a standard.
Yes ____
No ____
PUMP DRAIN VALVE
A manifold drain valve assembly will be supplied. This drain will provide the capability to drain
the entire pump by turning a single control. The valve assembly will consist of a stainless steel
plate and shaft in a bronze body with multiple ports. The drain valve control will be mounted on
the left side pump panel and identified as "Master Drain".
Yes ____
No ____
ENGINE PUMP HEAT EXCHANGER
The chassis’s engine that provides the power to drive the fire pump will have a supplementary
cooling system installed between the engine and the radiator that uses water from the discharge
side of the pump to cool the engine coolant through the use of a closed heat exchanger. The
water from the pump and the engine coolant will not be intermixed. This cooling system will be
controlled by a valve on the pump operator's panel, and will be clearly labeled “Engine Cooler”.
To prevent damage from freezing, the heat exchanger will be plumbed through the master pump
drain.
Yes ____
No ____
1/2" PUMP COOLER LINE
There will be a 1/2" line installed from the discharge side of the pump to the water tank. The
line will be used to cool the pump during long periods of pumping when water is not being
discharged. The pump cooler will be controlled with a quarter-turn ball valve on operators
panel, and will be clearly labeled "Pump Cooler".
Yes ____
No ____
PUMP COOLER CHECK VALVE
There will be a check valve installed in the pump cooler line to prevent tank water from back
flowing into the pump when it is not in use.
Yes ____
RFQ (Goods and Services) No.: 1220-41-25-09
No ____
49
INTAKE RELIEF VALVE
There will be an intake relief valve installed on the suction side of the pump. The valve will be
the preset type, adjustable from 75 to 250 PSI, and will be designed to prevent vibration from
altering the setting. The relief outlet will be directed below the pump with the discharge
terminating in a 2-1/2" male NST connection. The discharge will be away from the pump
operator and labeled "Do Not Cap".
The intake relief valve discharge shall be located below R1, for ease of connecting a hose.
Yes ____
No ____
PUMP MANUAL
Two (2) Pump Operation & Maintenance manuals will be supplied at the time of delivery.
Yes ____
No ____
PUMP VALVES
Except where noted, all manual valves will be Akron 8800 series or Elkhart Unibody, quarterturn, full flow, swing-out type. The flow regulating element of each valve will not change its
position under any condition of operation involving discharge pressures to the maximum
pressure of the pump. The means to prevent a change in position will be incorporated in the
operating mechanism and will be permitted to be manually controlled.
NOTE: All electric valves are to be Elkhart Unibody
Yes ____
No ____
SLOW CLOSE MECHANISMS
Gated intakes and discharges that are 3" or larger will be equipped with a mechanism to prevent
changing the position of the valve from full open to full close, or vice-versa, in less than 3
seconds as required by NFPA.
Yes ____
No ____
TANK TO PUMP CHECK VALVE
There will be a check valve between the pump suction and the booster tank valve. The check
valve will eliminate back flow into the water tank when the pump is connected to a pressurized
source.
Yes ____
No ____
TANK TO PUMP VALVE
There will be one (1) 3" manual full flow ball valve connected with a flexible hose from the tank
to the pump. The tank to pump valve will be controlled from the pump operator's panel.
Yes ____
No ____
TANK FILL VALVE
There will be one (1) 2" full-flow tank fill valve plumbed with 2" plumbing from the pump to the
tank. Installation will be completed with 2" high pressure flex hose. Stainless steel hose
couplings will be utilized. The tank fill valve will be controlled from the operator's control panel.
Yes ____
No ____
6" STEAMER SUCTION INLETS
There will be two (2) 6" male steamer inlets, one (1) on each side of the apparatus. The suction
fittings will include a removable die cast screen to provide cathodic protection for the pump thus
reducing corrosion.
Yes ____
RFQ (Goods and Services) No.: 1220-41-25-09
No ____
50
SHORT STEAMER BARREL - RIGHT SIDE
To accommodate an intake valve without exceeding the legal overall body width, a shorter
steamer barrel will be installed on the right side of the apparatus.
Yes ____
No ____
RIGHT STEAMER MASTER INTAKE VALVE ( ELECTRIC )
The right steamer will be equipped with a Hale model MIV-E, master intake valve. The valve
will be a full flow butterfly type designed to mount on the fire pump between the suction
extension and the suction tube behind the pump panel.
A pressure relief valve will be provided that is factory set to 125 PSI and field adjustable from 75
to 250 PSI. The pressure relief valve will provide overpressure protection for the suction hose
even when the intake valve is closed.
The inlet valve will be operated by a 12 VDC electric motor with remote capabilities. The valve
will be provided with a panel placard indicating control operations. The placard will have status
lights to indicate whether the valve is open, closed, or traversing from one position to another.
A panel mounted manual override will be provided to permit operation of the electric control
valve in the event of abnormal operating conditions. The manual override will be designed to
permit operation of the valve without the use of special tools or disassembly of the pump panel
or valve.
Yes ____
No ____
BLEEDER VALVE
There will be a Hale ABV, air bleeder valve, provided on the pump panel for the steamer / intake
equipped with a Hale MIV. The valve will be used to bleed off air or water as per NFPA
requirements.
The air bleeder control shall be located on the left side pump operator’s panel.
Yes ____
No ____
STEAMER INLET ADAPTER
There will be one (1) lightweight aluminum 30 degree elbow provided. Threads shall be: 6"
swivel female NST with long handles to 4" Storz.
The adapter shall be located on the right 6" steamer inlet.
Yes ____
No ____
4" STORZ CAP & CHAIN
There will be one (1) lightweight aluminum 4" Storz cap provided. A chain attachment will be
also supplied.
The Storz blind cap shall be located on the right 6" steamer inlet adapter.
One (1) 6" NST chrome plated long handle steamer cap will be provided.
Yes ____
No ____
GATED SUCTION INLETS
All suction valves, unless otherwise noted in the specifications, will be brass, quarter-turn, full
flow, and swing-out type. Each valve will be designed in such a manner that the action of water
against the regulating element will not affect its position.
Each valve will be individually attached to the manifold of the pump with stainless steel
(preferred) or schedule 40 galvanized pipe. The plumbing to the valve will contain a minimum of
elbows to keep friction loss to a minimum.
RFQ (Goods and Services) No.: 1220-41-25-09
51
The valves located in the pump compartment area will be partially recessed behind the panel
with the portion of the valve that contains water protected from the elements.
Yes ____
No ____
INTAKE DRAINS
Each gated intake will be equipped with a Class1 3/4" quarter turn bleeder valve. The bleeder
valve will be equipped with a chrome plated handle to provide a positive grip while personnel
are wearing gloves.
Yes ____
No ____
INTAKE TRIM PLATES
Each gated intake will have a polished cast aluminum or stainless steel trim plate around the
intake valve and fitting. The trim plate will be easily removable without the need to disturb the
valve.
Yes ____
No ____
Yes ____
No ____
INTAKE STRAINERS
Removable strainers will be provided with each gated intake.
LEFT SIDE 2-1/2" GATED INTAKE
There will be one (1) 2-1/2" gated intake provided on the left side of the pump compartment.
The intake will be furnished with a 2-1/2" valve and 2-1/2" plumbing. The intake will terminate
with a 2-1/2" BCT female chrome swivel.
The control for this valve shall be in the DOWN position when CLOSED, and in the UP position
when OPEN
There will also be a 2-1/2" BCT rocker lug plug with Chrome finish provided on the adapter. A
retention chain will be included with the plug.
Yes ____
No ____
RIGHT SIDE 2-1/2” GATED INTAKE
There will be one (1) 2-1/2” gated intake provided on the right side of the pump compartment.
The intake will be furnished with a 2-1/2” valve and 2-1/2” plumbing. The intake will terminate
with a 2-1/2” BCT female chrome swivel.
The control for this valve shall be in the DOWN position when CLOSED, and in the UP position
when OPEN
There will also be a 2-1/2” BCT rocker lug plug with chrome finish provided on the adapter. A
retention chain will be included with the plug.
Yes ____
No ____
RIGHT SIDE 4” GATED INTAKE
There will be one (1) 4” gated intake provided on the right side of the pump compartment. The
intake will be furnished with an 4” electric valve and 4” plumbing. The intake will terminate with
a 4” Storz adapter.
A pressure relief valve shall be provided that is factory set to 125 psi and field adjustable from
75 to 250 psi. The pressure relief valve shall provide overpressure protection for the suction
hose even when the intake valve is closed. The outlet of the pressure relief valve will have 21/2” NPT threads to allow directing the discharge flow away from the pump operator’s position.
RFQ (Goods and Services) No.: 1220-41-25-09
52
There will be one (1) 4” Storz blind cap with chain attached to the panel.
Yes ____
No ____
CROSSLAY PRECONNECT HOSE BED
Crosslay pre-connects will have 90 degree elbow type swivel on discharge outlets. The flooring
will be punched to allow for adequate ventilation and drainage.
The dividers between the hose bed areas will be fabricated of 3/16" aluminum.
mounted in a channel on each end for adjustability.
Yes ____
It will be
No ____
ABRADED FINISH CROSSLAY HOSEBED
The crosslay hose bed and dividers will have a maintenance free abraded finish.
Yes ____
No ____
VINYL CROSSLAY COVER
The crosslays shall have a vinyl coated nylon cover installed. The front edge of the cover shall
be retained in a "C" channel to prevent wind from lifting it. The back of the cover shall be
attached to the apparatus body with velcro.
The cover shall be black in color.
Yes ____
No ____
1-1/2" CROSSLAYS
There will be two (2) 1-1/2" crosslays above the side mount control panel. Each crosslay will be
plumbed with a full-flow 2" valve. High pressure flex hose with stainless steel couplings will be
used in plumbing the discharge to a 1-1/2" Male swivel elbow. The swivel for each crosslay
hose bed will be located outboard for ease of making connections while changing hose.
The 90 degree elbow swivel on the discharge outlet will terminate NPHS thread.
Each crosslay hose bed will have a capacity of 200' of 1-3/4", double jacket fire hose.
Crosslays are to hold the following hose configuration:
100' of 1 3/4" pre-connect, single stack of double jacket fire hose.
150' of 1 3/4" pre-connect, double stack of double jacket fire hose.
Yes ____
No ____
2-1/2" CROSSLAYS
There will be two (2) 2-1/2" crosslay above the side mounted operator's control panel. The
crosslay will be plumbed with a full-flow 2-1/2" valve. High pressure flex hose with stainless
steel couplings will be used in plumbing the discharge to a 2-1/2" Male swivel elbow. The swivel
for the crosslay hose bed will be located outboard for ease of making connections while
changing hose.
The crosslay hose bed will have a capacity of 200' of 2-1/2" double jacket fire hose.
Crosslays are to hold the following hose configuration:
200' of 2 1/2" pre-connect, double stack each.
Yes ____
RFQ (Goods and Services) No.: 1220-41-25-09
No ____
53
DISCHARGE ADAPTERS
There will be two (2) rigid female to male adapter with rocker lugs provided. Threads will be:
2-1/2" NST female x 2-1/2" BCT male.
The adapters shall be located on the 2-1/2" crosslays
Yes ____
No ____
DEADLAY HOSE BED
There will be one (1) 1-1/2" deadlay provided above the pump compartment. The deadlay hose
bed will have a minimum capacity of 200' of 1-1/2" double jacket fire hose.
The deadlay hosebed will be 7-1/2" wide.
Yes ____
No ____
CROSSLAY ROLLERS
Stainless steel rollers will be provided at each end of the crosslay hose bed to facilitate
deployment of hose. Vertical rollers will be installed on each side of the hose bed opening, and
a horizontal roller will be installed under the opening.
Yes ____
No ____
DRAIN VALVES
Each discharge 2-1/2" or larger, with the exception of the crosslays and hard to access
plumbing, will be equipped with a 3/4" quarter turn Class1 drain between the valve and the
discharge. There will be a chrome plated round handle provided on each drain valve to facilitate
use with a gloved hand.
Drain valves will be located in a row just above the running board and below the pump panel on
each side of the apparatus pump compartment to reduce clutter in the pump panel area. Each
drain valve will be color coded to match the appropriate line it is connected to. The drain valves
will be connected to the individual valves with flexible hose that is routed in such a manner as to
assure complete drainage. Discharge from the drain valves will be routed to below the
apparatus.
Yes ____
No ____
AUTOMATIC DRAINS
Crosslay and hard to access discharges will be equipped with Class1, model 34AD automatic
drains. These drains will open whenever the pressure in the discharge line drops below 5 PSI.
The drains will be located in areas that will allow the entire line to drain effectively. More than
one drain will be used in lines that are uneven along their length.
Where the drain valve is located above the frame rails of the chassis, the outlets will be
extended with hoses to below the chassis frame rails.
Yes ____
No ____
DISCHARGE ELBOWS
All discharges that are 2" or larger and are 42" or more above grade will be equipped with a
downward pointing elbow of 30 degrees or more.
Yes ____
RFQ (Goods and Services) No.: 1220-41-25-09
No ____
54
DISCHARGE CAPS
All discharges, except for those designated as pre-connects, will have a chrome cap. Caps for
discharges 2-1/2" and smaller will be secured to the apparatus with suitable chains.
Yes ____
No ____
DISCHARGE TRIM PLATES
Each gated discharge will have a polished cast aluminum or stainless steel trim plate around the
discharge valve and fitting. The trim plate shall be easily removable without the need to disturb
the valve.
Yes ____
No ____
LEFT SIDE 2-1/2" DISCHARGE
There will be one (1) 2-1/2" NST discharge on the left side of the pump compartment. The
discharge will be plumbed with a 2-1/2" valve and 2-1/2" plumbing.
Yes ____
No ____
DISCHARGE ADAPTER
There will be one (1) rigid female to male adapter with rocker lugs and Chrome finish provided.
Threads will be: 2-1/2" NST female x 2-1/2" BCT male.
The adapter shall be located on the left pump panel 2 1/2" discharge.
There will also be a 2-1/2" BCT rocker lug cap with Chrome finish provided on the adapter. A
retention chain will be included with the cap.
Yes ____
No ____
RIGHT SIDE 2-1/2" DISCHARGE
There will be one (1) 2-1/2" NST discharge on the right side of the pump compartment. The
discharge will be plumbed with a 2-1/2" valve and 2-1/2" plumbing.
Yes ____
No ____
DISCHARGE ADAPTER
There will be one (1) rigid female to male adapter with rocker lugs and Chrome finish provided.
Threads will be: 2-1/2" NST female x 2-1/2" BCT male.
The adapter shall be located on the right pump panel 2 1/2" discharge.
There will also be a 2-1/2" BCT rocker lug cap with Chrome finish provided on the adapter. A
retention chain will be included with the cap.
Yes ____
No ____
FRONT BUMPER 2-1/2" DISCHARGE
There will be one (1) 2-1/2" NST discharge installed to the left side of the front bumper. The
discharge will be plumbed with a 2-1/2" valve and 2-1/2" plumbing. High pressure flex hose with
stainless steel couplings will be used in the plumbing of this discharge.
Yes ____
No ____
CHROME DISCHARGE SWIVEL
The front bumper discharge will be equipped with a chrome swivel. The swivel assembly will
have a 2-1/2" victaulic pipe end and a 2-1/2" male NST end. The swivel will have a specially
deigned elbow that reduces friction loss.
Yes ____
RFQ (Goods and Services) No.: 1220-41-25-09
No ____
55
DISCHARGE ADAPTER
There will be one (1) rigid female to male adapter with rocker lugs and Chrome finish provided.
Threads will be: 2-1/2" NST female x 2-1/2" BCT male.
The adapter shall be located on the front bumper pre-connect.
Yes ____
No ____
DISCHARGE ADAPTER
There will be one (1) rigid female to male adapter with rocker lugs and Chrome finish provided.
Threads will be: 2-1/2" BCT female x 1-1/2" NPSH male.
The adapter shall be located on the front bumper pre-connect adapter.
Yes ____
No ____
RIGHT SIDE 4" LARGE DIAMETER DISCHARGE
There will be one (1) 4" NST discharge located on the right side pump panel. The discharge will
be plumbed with a 4" valve and 4" plumbing. Prefer the 4" discharge to be controlled by a
handwheel. The handwheel worm gear will be connected to the remote mounted valve via a rod
assembly. The handwheel shall turn a gear sector mounted on the valve for smoother and
easier operations under pressure.
A Position Indicator will show the position of the ball valve as per NFPA 1901. Opening and
closing speed will comply with the current NFPA Standard to minimize effects of water hammer.
NOTE: This discharge shall be capable of flowing either water or foam.
Yes ____
No ____
ELBOW ADAPTER
There will be one (1) lightweight aluminum 30 degree elbow provided. Threads shall be: 4"
swivel female NST with rocker lugs to 4" Storz.
The adapter shall be located on the 4" LDH.
Yes ____
No ____
DISCHARGE ADAPTER
There will be one (1) 4” to 2-1/2” lightweight aluminum adapter provided. Threads shall be: 4"
Storz with lugs with manual locks x 2-1/2" rigid male BCT.
The adapter shall be located on the 4" LDH.
There will also be a 2-1/2" BCT rocker lug cap with chrome finish provided on the adapter. A
retention chain will be included with the cap.
Yes ____
No ____
VALVE CONTROLS
All 2-1/2" or smaller valves will be controlled by a quarter turn locking type push/pull control with
direct linkages and universal yokes. Control rods will be hard coated anodized aluminum 3/4''
rod and polished chrome plated zinc handles.
The centerline of any valve control will be no more than 72" vertically above the platform that
serves as the pump operator's position.
Yes ____
RFQ (Goods and Services) No.: 1220-41-25-09
No ____
56
DELUGE MONITOR RISER ( ELECTRIC VALVE )
There will be one (1) 3" riser for a deluge monitor installed above the pump on the apparatus.
The riser pipe will be installed with a 3" electric valve, controlled from the pump operator's
panel.
Yes ____
No ____
ELKHART EXTENDER FOR DECK GUN
Extender is designed to provide better clearance for the monitor to allow for a wider coverage
range and address firefighter safety concerns;
18" Extender shall be compatible with the Elkhart Vulcan® Series of monitor; shall be designed
for use with monitor and nozzle flow ratings of 1250 gpm maximum with 100 psi nozzle pressure
with a maximum inlet pressure rating of 200 psi;
Shall be electrically actuated through a pump panel pushbutton control pad and designed for a
static load of up to 2500 pounds in any position;
Shall allow deployment of the monitor in 10 seconds;
Installation kit shall have an in-cab warning light that shall alert the driver when unit is not
retracted;
Pressure switch shall be provided to limit movement when internal pressure
exceeds 10 psi to avoid injury to personnel and damage to equipment;
Automatic drain system shall be provided on the vertical piping to drain all water from the
monitor and piping upon closing of the water valve;
Shall have a 3" Victaulic base by a 3" Flange outlet for attachment to apparatus piping;
Extender package shall include all items required for 12 volt installation.
Yes ____
No ____
ELKHART VULCAN RF MONITOR
Monitor to be an Elkhart Vulcan RF c/w hand held transmitter, 282-A stream shaper, and ST194 quad stacked tips.
Yes ____
No ____
ELKHART SM-1250E NOZZLE
An Elkhart Select-O-Matic master stream nozzle model SM-1250E complete with a 2.5” swivel
base shall be provided. The nozzle shall be equipped with an electric pattern control. The
nozzle shall be designed for flows of 1250 gpm. The nozzle shall be rated at an operating
pressure of 75 psi.
Yes ____
No ____
FOAM PRO 2002 SINGLE FOAM SYSTEM
The apparatus shall be equipped with a Hypro FoamPro 2002 electronic, fully automatic,
variable speed, direct injection, discharge side foam proportioning system. The system will be
capable of handling Class A foam concentrates and most Class B foam concentrates.
The foam proportioning operation will be based on direct measurement of water flows, and
remain consistent within the specified flows and pressures. The system will be equipped with a
digital electronic control display, suitable for installation on the pump panel.
Incorporated within the control display will be a microprocessor that receives input from the
system flow meter, while also monitoring foam concentrate pump output, comparing values
toensure that the operator preset proportional amount of foam concentrate is injected into the
discharge side of the fire pump.
RFQ (Goods and Services) No.: 1220-41-25-09
57
A paddlewheel type flow meter will be installed in a manifold for the specified foam capable
discharges.
The digital computer control display will enable the pump operator to perform the following
control and operation functions for the foam proportioning system:









Provide push-button control of foam proportioning rates from 0.1% to 9.9% in 0.1%
increments.
Show current gallon-per-minute water flow rate.
Show total gallons of water discharged, during and after foam operations are completed.
Show total gallons of foam concentrate consumed.
Simulate flow rates for manual operation.
Perform set-up and diagnostic functions for the computer control microprocessor.
Flash a low concentrate warning when the foam concentrate tank runs low.
Flash a no concentrate warning and shut the foam concentrate pump off, preventing
damage to the pump, should the foam tank empty.

A 12 volt electric motor driven positive displacement foam concentrate pump, rated up to 5.0
GPM, with operating pressures up to 400 PSI, will be installed in a suitable compartment near
the apparatus pump house. A pump motor electronic driver (mounted to the base of the pump)
will receive signals from the computer control display, and power the 3/4 horsepower electric
motor directly coupled to the concentrate pump in a variable speed duty cycle to ensure that the
correct proportion of concentrate preset by the pump operator is injected into the water stream.
System Capacity will be as follows:
Foam
Concentrate
0.2%
0.5%
1.0%
3.0%
2002 Maximum
Water Flow GPM ( LPM )
2500 ( 9464 )
1000 ( 3785 )
500 ( 1893 )
166 ( 628 )
A full flow check valve will be provided to prevent foam contamination of fire pump and water
tank or water contamination of foam tank.
Components of the complete proportioning system as described above will include:
 Operator control and display.
 One (1) Paddlewheel flow meter.
 Pump and electric motor/motor driven.
 Wiring harnesses.
 Foam injection check valve.
 One (1) Low level foam tank switch.

Installation and operation manual will be provided for the unit, along with a one-year limited
warranty.
The foam system will be plumbed to the following discharges:






Two (2) 1-1/2" crosslays
One (1) 2-1/2" crosslay
One (1) 2-1/2” front bumper discharge
One (1) 4” right side discharge
Yes ____
RFQ (Goods and Services) No.: 1220-41-25-09
No ____
58
BYPASS SYSTEM FOR RIGHT SIDE 4” DISCHARGE
There shall be a bypass system provided with the Foam System that shall allow the right side 4”
discharge to either flow water or foam. The bypass shall be plumbed into the 4” discharge with
3" plumbing and a 3" valve. The bypass valve shall be controlled by a Hand wheel. The hand
wheel worm gear shall be connected to the remote mounted valve via a rod assembly. The
hand wheel shall turn a gear sector mounted on the valve for smoother and easier operations
under pressure.
A position Indicator shall show the position of the ball valve as per NFPA 1901. Opening and
closing speed shall comply with the current NFPA Standard to minimize effects of water
hammer.
Yes ____
No ____
FOAM PRO REFILL SYSTEM
The apparatus will be equipped with an electronic, automatic concentrate refill system. It will be
separate from the proportioning system to allow for simultaneous operations. The system will
be capable of handling Class A or Class B foam concentrate. The apparatus will be plumbed
from the externally accessed intake/flush port to the foam cell. The external intake/flush
connection will be quick connect, cam-lock type and incorporated a check valve to prevent
backflow. The refill line will be positioned in the lower portion of the foam cell to minimize
agitation. The refill operation will be based on direct measurement of the concentrate level in
the cell and the refill pump intake performance. The system must be capable of automatically
stopping when the foam cell is full and warn the operator when the concentrate source is empty
or any other conditions preventing flow occurs. The system will be equipped and electronic
control suitable for installation on the pump panel. Incorporated within the control will be a
microprocessor that receives input from the system while also monitoring foam concentrate
pump output. An all bronze three-way valve will be included to allow that operator to flush the
system after use.
A 12-volt electric motor driven positive concentrate pump, with a minimum of 10 gpm @ 20 psi
rating, with concentrate viscosity exceeding 5500 cps, will be installed per manufacturer
recommendations. A pump motor electronic driver will receive signals from the computer
control display and power the electric motor directly coupled to the concentrate pump. The
system will receive readings when the concentrate tank is full and stop operation to prevent
overfill. The system will terminate operations when flow is not detected on the intake side for 12
seconds.
Yes ____
No ____
POLYPROPYLENE FOAM CELL
There will be one (1) 25 imperial gallon polypropylene foam cell incorporated into the
polypropylene water tank.
There will be one (1) pressure/vacuum vent installed on the foam tank.
There will be one (1) drain hose connected to the foam cell. The drain will have a 1/4 turn valve
installed inside the pump house and it will drain below the frame rail of the chassis.
Yes ____
RFQ (Goods and Services) No.: 1220-41-25-09
No ____
59
FOAM TANK LEVEL GAUGE
The apparatus shall be equipped with one (1) Class1 "Intelli-Tank" Level Gauge for indicating
foam level. The Tank Level Gauge shall indicate the liquid level on an easy to read LED display
and show increments of 1/8 of a tank.
Each tank level gauge system shall include:
1) A pressure transducer that is mounted on the outside of the tank in an easily accessible
area. Sealed foam tanks will require zero pressure vacuum vents.
2) A super bright LED 4-light display with a visual indication at nine accurate levels.
3) A set of weather resistant connectors to connect to the digital display, to the pressure
transducer and to the apparatus power.
Yes ____
No ____
WATER TANK
The water tank will have a capacity of 500 Imp Gallons. Certification of the tank capacity to be
recorded on the manufacturer's record of construction and to be provided to the purchaser upon
delivery of the apparatus.
Yes ____
No ____
TANK CONSTRUCTION
The Poly-Tank will be constructed of 1/2" thick polypropylene sheet stock. This material will be
a noncorrosive stress relieved thermoplastic, black in color, and U.V. stabilized for maximum
protection.
Yes ____
No ____
TANK BAFFLES
The transverse swash partitions will be manufactured of 3/8" polypropylene (natural in color)
and extend from approximately 4" off the floor to just under the cover. The longitudinal swash
partitions will be constructed of 3/8" polypropylene (natural in color) and extend to the floor of
the tank through the cover to allow for positive welding and maximum integrity. All partitions will
be equipped with vent and air holes to permit movement of air and water between
compartments. The partitions will be designed to provide maximum water flow. All swash
partitions will interlock with one another and be welded to each other as well as to the walls of
the tank.
Yes ____
No ____
TANK SUMP
There will be one (1) sump in the bottom of the water tank. The sump will be constructed of 1/2"
polypropylene and will be located in the left front quarter of the tank. On all tanks that require a
front suction, a 4" schedule 40 polypropylene pipe will be installed that will incorporate a dip
tube from the front of the tank to the sump location. The sump will be used as a combination
clean-out and drain. All tanks will have an anti-swirl plate located approximately 2" above the
sump to pre-vent air from being entrained in the water while pumping.
Yes ____
No ____
TANK FILL CONNECTION
All tank fill couplings will be backed with flow deflectors to break up the stream of water entering
the tank, and will be capable of withstanding sustained fill rates of up to 1,000 GPM.
Yes ____
RFQ (Goods and Services) No.: 1220-41-25-09
No ____
60
TANK LID
The tank lid will be constructed of 1/2" thick polypropylene to incorporate a multi three-piece
locking design that allows for individual removal and inspection if necessary. The tank lid will be
recessed 3/8" from the top of the tank and will be welded to both sides and longitudinal
partitions for maximum integrity. Each one of the lids will have hold downs consisting of 2"
polypropylene dowels spaced a maximum of 30" apart. These dowels will extend through the
covers and will assist in keeping the covers rigid under fast filling conditions. A minimum of two
lifting dowels will be drilled and tapped 1/2" x 13" to accommodate the lifting eyes.
Yes ____
No ____
TANK MOUNTING
The tank will rest on the body cross members in conjunction with such additional cross
members, as required by the tank manufacturer.
The tank will be isolated from the cross members through the use of hard rubber strips with, a
minimum Rockwell Hardness of 60 durometer. Additionally, the tank will be supported around
the entire perimeter and captured both front and rear as well as side to side to prevent the tank
from shifting during vehicle operation.
Although the tank will be designed on a free floating suspension principle, it will be required that
the tank have adequate hold down restraints to minimize movement during vehicle operation.
The tank will be completely removable without disturbing or dismantling the apparatus structure.
Yes ____
No ____
TANK FILL / VENT
The tank will have a combination vent and manual fill tower marked "Water Fill." The fill tower
will be constructed of 1/2" polypropylene and will be a minimum dimension of 8" x 8" at the outer
perimeter.
The tower will be located in the left front corner of the tank. The tower will have a 1/4" thick
removable polypropylene screen and a polypropylene hinged-type cover. Inside the fill tower,
approximately 4" down from the top, will be fastened a combination vent overflow pipe. The
vent overflow will be a minimum of schedule 40 polypropylene pipe that is designed to run
through the tank, and will be piped behind the rear wheels so as to obtain maximum traction.
Yes ____
No ____
TANK DRAIN VALVE
One (1) 1-1/2" tank drain valve will be provided under the tank sump. The valve will have a
locking lever to prevent accidental draining of the tank.
Yes ____
No ____
WATER TANK LEVEL GAUGE
The apparatus will be equipped with one (1) Class1 "Intelli-Tank" Level Gauge on the pump
operators control panel. The Tank Level Gauge will indicate the water level on an easy to read
LED display and show increments of 1/8 of a tank.
The tank level gauge system will include:
1) A pressure transducer that is mounted on the outside of the tank in an easily accessible
area. Sealed foam tanks will require zero pressure vacuum vents.
2) A super bright LED 4-ight display with a visual indication at nine accurate levels.
3) A set of weather resistant connectors to connect to the digital display, to the pressure
transducer and to the apparatus power.
Yes ____
RFQ (Goods and Services) No.: 1220-41-25-09
No ____
61
CONTROL PANEL
The left side of the pump enclosure will be divided into two sections. The lower section will be
where all valve controls, the primer control, the discharge relief valve controls (pilot valve), and
other mechanical controls are located. This surface will be referred to as the "control panel".
All valve controls will be the self locking type, activated by either direct control or with a direct
linkage utilizing friction locking bell cranks and universal ball swivels. The primary valve
handles will have color coded tags installed in a recessed area to clearly denote the purpose of
each control.
Yes ____
No ____
INSTRUMENT PANEL
The surface above the control panel will contain all instruments, gauges, test fittings, and
optional controls. This surface will be referred to as the "instrument panel". The instrument
panel will be independent and hinged and latched so that it may be opened. All instruments,
gauges, and other equipment will be installed with sufficient slack in any cabling, tubing, or
plumbing to allow the panel to swivel to the fully open position.
Yes ____
No ____
COLOR CODED LABELS
To improve identification of discharges and intakes, color coded tags will be provided. The tags
will utilize an etching process to provide easy visibility and improved field service life. Tags will
be affixed using an industrial grade adhesive backing, eliminating the need for pop rivets or
screws into the panel or control handle.
Yes ____
No ____
RIGHT SIDE PUMP PANEL
A single panel will be installed on the right side of the pump enclosure. This will be the area
where any right side discharges, inlets, steamers, and other pump associated equipment are
located. This panel will be easily removable. It will be fully removable for pump and plumbing
access without the need to use hand tools. Any electrical equipment that may be installed will
be equipped with connectors so they may be easily separated from the opening created when
the below described front access panel is removed.
Yes ____
No ____
PUMP PANEL LIGHTS
The pump operator's control panel and the right side pump panel will each be illuminated by On
Scene Solutions LED light strips. Each light assembly will have a plastic or lexan lens to protect
the lamp from the elements.
The pump panel lights will become energized upon setting the parking brake so the gauge
information provided may be consulted at any time the apparatus is parked.
A stainless steel shield will be installed over the pump panel lights to further protect them from
the elements and to act as a reflector for additional illumination.
Yes ____
No ____
PANEL SURFACES
The control panel, instrument panel, and right side pump panel will be fabricated from
a minimum of 16 gauge stainless steel with brushed finish.
Yes ____
RFQ (Goods and Services) No.: 1220-41-25-09
No ____
62
PRESSURE / VACUUM TEST PORTS
Class1 model 102709 pressure and vacuum test ports will be provided on the pump panel.
Yes ____
No ____
PUMP COOLER VALVE
Class1 model 34BV pump cooling control valve will be provided on the pump panel.
Yes ____
No ____
ENGINE COOLER VALVE
Class1 model 34BV engine cooling control valve will be provided on the pump panel.
Yes ____
No ____
WHITE FACE / BLACK NUMERAL GAUGE DISPLAY
The master pump gauges and individual pressure gauges will have a white face with black
numbers and lettering. This will provide a high contrast and allow the gauges to be easily read
by the operator.
Yes ____
No ____
CLASS1 PRESSURE GAUGES
There will be nine (9) Class1 individual pressure gauges installed on the pump panel. Each
gauge will have dual readout capabilities, 0-400 PSI or -100-2750 kPa. The gauges will be a
minimum of 2-1/2" in diameter.
Yes ____
No ____
CLASS1 PRESSURE GAUGES
There will be two (2) Class1 individual pressure gauges installed on the pump panel. Each
gauge will have dual readout capabilities, -30-400 PSI or -100-2750 kPa. The gauges will be a
minimum of 4-1/2" in diameter.
Yes ____
No ____
PUMP PANEL SPEAKER
There shall be one (1) external weatherproof speaker, Motorola HSN4018C, w/ on-off switch
installed on the pump operator's panel. There is to be speaker wire run to the center dash
access panel, with sufficient pigtail to attach to the customer radio.
Yes ____
No ____
Yes ____
No ____
AIR HORN BUTTON ON PUMP PANEL
One (1) air horn button shall be provided on the pump panel.
INDEPENDENT PUMP COMPARTMENT
The main body and the pump compartment will be fabricated as individual units. Both the body
and pump compartment will be fabricated using precision holding fixtures to ensure proper
dimensions. All attachment points will be heavily reinforced.
Yes ____
No ____
5052-H32 ALUMINUM
All body compartments will be fabricated of 1/8", 5052-H32, smooth aluminum plate.
State how body is formed
Yes ____
RFQ (Goods and Services) No.: 1220-41-25-09
No ____
63
BODY SUBFRAME
To assure proper body alignment and clearance, the body sub frame will be constructed in a jig
and fitted directly on the chassis.
The chassis frame rails will be fitted with fiber reinforced rubber to isolate the body frame
members from direct contact with chassis frame rails.
The main body sub frame will be constructed from steel tubing. The sub frame will run the full
length of the body and shall be spaced the same width as the chassis frame rails. The main
sub frame will also be the integral support for the water tank. Vertical drop tubes will be welded
to the sub frame. From these vertical drop tubes will extend cross members constructed of
steel angle.
These cross members will extend out to support the compartments. Cross members will be
located at the front and rear of the body and in front and rear of the wheel well opening.
The compartment area behind the rear axle will be supported by a drop frame fabricated of steel
tube and steel angles. The rear drop frame will be constructed using vertical drop tubes,
welded to the main sub frame. All drop frame structures will be welded directly to the body sub
frame to allow the body to be a completely separate structure from the chassis.
Yes ____
No ____
BODY MOUNTING
The body sub frame will be fastened to the chassis frame with flanged body mounts to prevent
the body from moving. Each mount will be configured using a two-piece bracket. The two (2)
brackets will be fabricated of steel plates. The plates will be painted to prevent any corrosion.
“U” bolts will not be accepted.
State how Body/Subframe is mounted
Yes ____
No ____
LEFT SIDE COMPARTMENTS
COMPARTMENT L1
There will be a full height compartment located ahead of the rear wheels on the left side of the
apparatus body. This compartment will be designated as L1. It will be equipped with a roll-up
door.
Door Opening - 30" Wide x min. 59" High
The compartment will have a usable depth of min. 25" in the lower portion and min. 15" in the
upper portion.
Yes ____
No ____
COMPARTMENT L2
There will be an upper compartment located over the rear wheel on the left side of the
apparatus body. This compartment will be designated as L2. The compartment will be
equipped with a roll-up door.
Door Opening - 62" Wide x min. 28" High
The compartment will have a usable depth 15".
Yes ____
RFQ (Goods and Services) No.: 1220-41-25-09
No ____
64
COMPARTMENT L3
There will be a full height compartment located behind the rear wheels on the left side of the
apparatus body. This compartment will be designated as L3. The compartment will be
equipped with a roll-up door.
Door Opening - 51" Wide x min. 59" High
The compartment will have a usable depth of min. 25" in the lower portion and min.15" in the
upper portion.
Yes ____
No ____
RIGHT SIDE COMPARTMENTS
COMPARTMENT R1
There will be a full height compartment located ahead of the rear wheels on the right side of the
apparatus body. This compartment will be designated as R1. It will be equipped with a roll-up
door.
Door Opening - 30" Wide x min. 59" High
The compartment will have a usable depth of min. 25" in the lower portion and min. 15" in the
upper portion.
Yes ____
No ____
COMPARTMENT R2
There will be an upper compartment located over the rear wheel on the right side of the
apparatus body. This compartment will be designated as R2. It will be equipped with a roll-up
door.
Door Opening - 36" Wide x 28" High
The compartment will have a usable depth of min. 15".
Yes ____
No ____
COMPARTMENT R3
There will be a full height compartment located behind the rear wheels on the right side of the
apparatus body. This compartment will be designated as R3. It will be equipped with a roll-up
door.
Door Opening - 51" Wide x min. 59" High
The compartment will have a usable depth of min. 25" in the lower portion and min. 15" in the
upper portion.
Yes ____
No ____
NON-TRANSVERSE REAR COMPARTMENTS
Bulkheads will be installed in the back of the lower left and right side compartments to separate
them from the rear facing, low compartment.
Yes ____
No ____
REAR COMPARTMENT
There will be a full height compartment located at the rear of the apparatus body. This
compartment will be designated as T1 within these specifications and any ensuing paperwork or
drawings after contract execution. It will be equipped with a roll-up door.
Door Opening – approx. 47" Wide x 33" High
The compartment will have a usable depth of 30".
Yes ____
RFQ (Goods and Services) No.: 1220-41-25-09
No ____
65
SWEEP-OUT CONSTRUCTION
Compartment floors will have a "sweep-out" design with door opening threshold positioned
lower than compartment floor, permitting easy cleaning of compartments.
Yes ____
No ____
ROLL-UP DOORS ( SATIN FINISH )
Roll-up doors will be ROM shutter type with 34 millimeter slats that roll onto a spool at the top of
the compartment.
Yes ____
No ____
ROBINSON ROLL UP DOOR HANDLES
The roll-up door will be supplied with a full width handle for ease of opening with only one hand,
allowing quick access to equipment.
Yes ____
No ____
NFPA STEP REQUIREMENTS
All steps will have a surface area of at least 35 square inches and will be able to withstand a
load of at least 500 pounds. Steps will be provided at any area that personnel may need to
climb and will be adequately lighted. Each folding step will have two large open slots to prevent
buildup of ice or mud and to provide a handhold when necessary.
Steps will be provided in the following locations:
Three (3) folding steps on the left front compartment
Three (3) folding steps on the right front compartment
Six (6) steps at the rear of the body, three (3) on each side.
NOTE: The exact number of steps provided may vary depending upon body configuration and
options.
Yes ____
No ____
RIGHT SIDE PUMP ACCESS DOOR
There will be a treadbrite door above the right hand side pump panel to allow access to the
pump compartment. The horizontally hinged panel will be of the single pan design and shall be
positively latched in the closed position utilizing a pushbutton latch. A gas strut will be provided
on the door.
This door will be wired into the hazard warning light circuit. An aluminum sill protector will be
installed on the bottom of the door opening to protect the paint from chipping and scratching.
Access Door is to be horizontally hinged.
Yes ____
No ____
PUMP ACCESS WITH DOOR
There will be a treadbrite access panel provided on the front of the pump compartment. The
panel will be of the single pan design and shall be positively latched in the closed position. An
aluminum sill protector will be installed on the bottom of the door opening to protect the paint
from chipping and scratching.
Yes ____
RFQ (Goods and Services) No.: 1220-41-25-09
No ____
66
COMPARTMENT VENTING
Each body compartment will be properly vented in a manner that will reduce the amount of dirt
and water that may enter the compartment. Venting will be directly to the atmosphere rather
than into another compartment, which would only spread moisture throughout the body rather
than dissipate it.
Additionally, each compartment will be equipped with drain holes to allow standing water to exit.
Yes ____
No ____
HEAT DEFLECTOR SHIELD
Increased standards for emission have caused most exhaust temperatures to increase. To
keep the exhaust heat from affecting anything stored in the body, a deflector shield is to be
installed to aid in dissipating the heat.
Yes ____
No ____
HATCH COMPARTMENT-LEFT SIDE
There will be a hatch compartment located on top of the left side high compartments. The
compartment shall be constructed as an integral part of the apparatus body and have two lift-up
treadbrite doors with gas powered assists and water tight latches.
The Hatch compartment is to be notched at the rear to allow the rotator to be lowered.
Yes ____
No ____
LEFT SIDE MODULAR RUNNING BOARD
A modular running board will be installed on the left side of the pump compartment module.
The running board will be constructed of non-slip treadbrite. The outside edge of the running
board will be flush with the rub rail that is installed on the body to maintain a uniform
appearance.
All running boards will be installed with sufficient support to form a sturdy, non-deflecting step
area for personnel.
Yes ____
No ____
LEFT SIDE PUMP OPERATOR'S PLATFORM
An Innovative Industries pull out platform shall be provided at the pump operator's control panel
that can support a maximum of 500 pounds. The top surface of the platform shall be
constructed of aluminum serrated bar grating for ease of maintenance and to provide a slip
resistant surface for the operator. The platform shall lock in both the retracted and the extended
position. The pull out platform shall be wired to the door ajar circuit.
The pull out platform roller assembly shall have a powder coat finish for added corrosion
protection.
Yes ____
No ____
RIGHT SIDE MODULAR RUNNING BOARD
A modular running board will be installed on the right side of the pump compartment module.
The running board will be constructed of non-slip treadbrite. The outside edge of the running
board will be flush with the rub rail that is installed on the body to maintain a uniform
appearance.
All running boards will be installed with sufficient support to form a sturdy, non-deflecting step
area for personnel.
Yes ____
RFQ (Goods and Services) No.: 1220-41-25-09
No ____
67
RIGHT SIDE PUMP OPERATOR'S PLATFORM
An Innovative Industries pull out platform shall be provided at the right side pump panel that can
support a maximum of 500 pounds. The top surface of the platform shall be constructed of
aluminum serrated bar grating for ease of maintenance and to provide a slip resistant surface
for the operator. The platform shall lock in both the retracted and the extended position. The
pull out platform shall be wired to the door ajar circuit.
The pull out platform roller assembly shall have a powder coat finish for added corrosion
protection.
Yes ____
No ____
MODULAR REAR TAIL BOARD
A modular bolt-on tail board will be installed on the rear of the apparatus to form a step area.
The rear tail board will be constructed of non-slip treadbrite. The recessed rear tail board will be
installed between the left and right side body, below the rear compartments.
All running boards and rear tail board will be installed with sufficient support to form a sturdy,
non-deflecting step area for personnel.
Yes ____
No ____
PUMP PANEL VERTICAL HOSE COMPARTMENT - RIGHT
There will be soft suction hose compartment vertically recessed in the pump panel on the right
side.
The hosewell shall hold 50' of 5" hose. The LDH roll measures 9"W X 26"H X 17"D.
The bottom of the hosewell is to be ramped.
There is to be a strap provided with the pump panel hose compartment. The strap will be
installed on the compartment to retain the hose.
Yes ____
No ____
STAINLESS SCREWS
Stainless steel screws will be provided throughout the body in locations such as: overlays, pump
panels, and other numerous hardware mounting locations.
Yes ____
No ____
STEPPING, STANDING, WALKING SURFACES
All exterior surfaces designated by the manufacturer as stepping, standing, or walking areas will
be constructed of aluminum or stainless steel, Grip Strut or Textured Treadbrite and will provide
a highly slip resistant surface, even when the surface is wet. All interior surfaces designated by
the manufacturer as stepping, standing, or walking areas will be slip resistant when the surface
is dry.
The degree of slip resistance will be in compliance with the intent of NFPA 1901 newest version.
It is the desire of the fire department to purchase an apparatus that utilizes aluminum treadplate
as an overlay of the main apparatus body structure. Aluminum treadplate may also be utilized
in the construction of enclosure doors, lids and covers where applicable. Aluminum treadplate
is not to be utilized as a main structural member of the apparatus body, compartments, or pump
enclosure.
Yes ____
RFQ (Goods and Services) No.: 1220-41-25-09
No ____
68
TREADPLATE OVERLAYS
The following areas will have treadplate overlays installed:






Front compartment vertical areas on both sides.
The top surface of all side compartments.
The rear surface of the body module between the rear compartment and the vertical
handrail.
The rear surface of the body module above the rear compartment extending in width
between the hose bed risers.
Yes ____
No ____
REAR WHEEL WELLS
The fenders will be integral with the body sides and compartments with a seamless appearance.
The fenders will be fitted with bolt-in removable full circular inner liners in the wheel well area for
ease of cleaning and maintenance. There will be sufficient clearance provided in the wheel well
to allow the use of tire chains when the apparatus fully loaded.
Yes ____
No ____
REAR FENDERETTES
Two (2) stainless steel fenderettes will be installed at the outboard edge of the rear wheel well
area, one on each side. The fenderettes will be constructed of stainless steel that has been
polished to a high quality finish.
Yes ____
No ____
BODY RUB RAILS
Rub rails will be installed beneath the compartment doors to protect them from damage should
the body be brushed or rubbed against another object.
State design of rub rails:
Yes ____
No ____
REAR TOW EYE
Minimum one (1) rear tow eye will be installed directly below the rear of the chassis frame rails.
The tow eye shall be capable of a 15,000 lb. straight pull rating without causing any damage to
the body.
Yes ____
No ____
HANDRAILS
Handrails will be constructed of extruded aluminum of not less than 1-1/4" in diameter. All railing
escutcheons and brackets will be chrome plated, and will be bolted to the body with stainless
steel bolts. The lower bracket on all vertical handrails will have a drain hole drilled in it at the
lowest point. Handrails will be provided in the following areas:






Horizontal rear hand rail above the rear center compartment.
Grab handle on top of catwalk on the left side of the apparatus in front of the tank fill tower.
Grab handle on top of catwalk on the right side of the apparatus.
Left rear vertical hand rail from top of body to just above the rear step.
Right rear vertical hand rail from top of body to just above the rear step.

Yes ____
RFQ (Goods and Services) No.: 1220-41-25-09
No ____
69
HYDRAULIC LADDER RACK
The ladders will be mounted above the high compartments on the right side of the apparatus on
a pivoting ladder rack. The pivoting ladder rack will be operated hydraulically and controlled by
electric solenoid valves, lowering the ladders firmly to shoulder height for easy removal and
reloading.
The control switch will be located on the right side of the body to allow viewing the ladder rack
when operating the mechanism. The control will be wired to the parking brake and will only be
operable when the parking brake is applied.
The ladder rack will modular in design and built in a "T" shape pivoting on an approx. 20 inch
wide arm. The module will be located between the high side compartments. There will be no
guide arms or stabilizer arms located on the ends of the folding ladder rack. The right side
compartments will be accessible when the ladder rack is in either the up or down position.
When in the up position the ladder rack lifting mechanism will be fully retracted into the
apparatus body and is flush with the side of the apparatus. Pilot operated check valves will be
installed in the hydraulic system to lock the rack in the stored position by maintaining pressure
on the hydraulic cylinder.
There will be a master shut off switch and a flashing indicator light on the chassis dash to warn
the driver when the ladder rack is in the down position, or in motion when the chassis parking
brake is disengaged. The warning light will be operative regardless of the position of the master
switch.
Reflective striping will be applied to the ladder rack assembly in a manner that will readily
indicate a hazard or obstruction to personnel.
In addition to the reflective striping, flashing LED lights will be affixed to the front and rear of the
ladder rack. These lights will automatically become energized any time the ladder rack is not
fully bedded.
Yes ____
No ____
LADDER RACK SHIELD
There will be a smooth body colored painted shield installed on the hydraulic ladder rack. The
shield will protect the lifting mechanism of the ladder rack when in the up and stored position.
Yes ____
No ____
GROUND LADDERS
The ground ladder brackets will have quick release spring loaded latches. The holding
mechanism will have be designed to clamp the ladders at two separate areas. This provision
will allow the sectional ladder to still be clamped into position when the roof ladder has been
removed.
The following ladders will be provided:
 One (1) 10' Folding attic ladder, Duo Safety 585A
 One (1) 14' Roof ladder, Duo Safety 775A
 One (1) 35' Three section extension ladder, Duo Safety 1225A

Yes ____
No ____
ALUMINUM TUBES FOR PIKE POLE STORAGE
There will be two (2) aluminum tubes for storage of pike poles installed on the folding ladder
rack.
RFQ (Goods and Services) No.: 1220-41-25-09
70
The following pike poles will be provided:
 One (1) 6' Pike Pole, Duo Safety
 One (1) 12' Pike Pole, Duo Safety

Yes ____
No ____
INTERLOCKING TILES
There will be interlocking tiles provided with the apparatus and installed in compartments.
Yes ____
No ____
ADJUSTABLE SHELVES
There will be nine (11) adjustable shelves installed on the apparatus. The shelves will be
constructed of 3/16" aluminum sheet with 2" lips. The shelves will have an abraded finish. The
shelves will be designed in such a manner that will allow liquids to readily drain when spilled.
The shelves shall be installed as follows:
L1:
One (1) shelf in the upper 15" D portion.
L3:
Two (2) shelves total, both in the upper 15" D portion.
R1: Two (2) shelves total.
One (1) shelf in the upper 15" D portion.
One (1) half depth shelf in the lower portion below the transition point.
R2: One (1) shelf.
R3: Two (2) shelves total, both in the upper 15" D portion.
T-A: One (1) shelf.
Yes ____
No ____
ROLL OUT EQUIPMENT TRAY
There will be one (1) rollout tray installed on the apparatus.
The lower tray will be provided with a SlideMaster™, roller type assembly. The roller assembly
will have a rated capacity of 150lb end load, 300lb distributed load, and will have 100%
extension capabilities. A mechanical lock assembly will be provided to lock the tray in the
extended position and the retracted position. The tray will be constructed of 3/16" aluminum
sheet with 3" lips. The tray will have an abraded finish.
The tray roller assembly shall have a power coated finish for added corrosion protection.
The roll-out tray shall be installed in the T-A compartment.
Yes ____
No ____
ALUMINUM MOUNTING AND FLOOR PLATE
There will be one (1) 3/16" thick, 5052-H32 aluminum plate installed on the back wall of one (1)
compartment. The plate will be spaced away from the back wall of the compartment with
unistrut channels which shall also be used as an easy means of removing the plate to mount
equipment brackets. The plate will have an abraded finish.
There will be one (1) 3/16" thick, 5052-H32 aluminum plate installed on the floor of one (1)
compartment. The plate will be mounted to the interlocking tiles. The plate will have an abraded
finish. Exact mounting will be determined at the pre-construction meeting
These aluminum plates shall be installed in the L2 compartment.
Yes ____
RFQ (Goods and Services) No.: 1220-41-25-09
No ____
71
AIR BOTTLE COMPARTMENTS
There will be four (4) single cylinder air bottle compartments installed in the rear wheel well
area. The tubes will be constructed from injection molded plastic to reduce damage to the air
cylinders. There will be a drain hole in the rear of the compartment.
Yes ____
No ____
AIR BOTTLE COMPARTMENT DOORS ( O-RING GASKETS )
The single air bottle compartment will have a Cast Products hinged door with an o-ring gasket.
Yes ____
No ____
HOSE BED CAPACITY
The hosebed shall have the capacity for 800' of 4" hose and 800' of 2 1/2" hose.
Yes ____
No ____
HOSE BED
The hose bed compartment will have a minimum of 30 cubic feet of storage space in
accordance with NFPA latest edition 1901.
Yes ____
No ____
HOSE BED FLOORING
All hose beds shall have fiberglass, aluminum, or splinter free wood slats with varnished or
similar coating.
State type of hose bed flooring.
Yes ____
No ____
ALUMINUM HOSE BED PARTITION
One (1) hose bed partition will be installed in the hose bed. The partition will be fabricated from
1/4" smooth aluminum plate and an aluminum extrusion.
The partition will be mounted on hot-dipped galvanized slide rails at the front and rear of the
hose bed.
Where no obstruction such as a fill tower is present, the slide rails will allow full movement of a
hose partition along the width of the hose bed. This will provide the capability for variable hose
load configurations & capacities.
The hose bed partition will have a maintenance free abraded finish.
Yes ____
No ____
POWER OPERATED ALUMINUM HOSE BED COVER
Prefer the hose bed storage area to be covered with two (2) hinged aluminum doors. The doors
will be hinged on the outside edges, utilizing full length stainless steel piano hinges. The doors
will lift up and out towards the outside of the body. The doors will be fabricated with 1/8"
aluminum inner panel for superior strength. The outside sheet will be constructed of non-slip
treadbrite.
The hose bed doors will be power operated utilizing a self-contained hydraulic system. The
system pressure of the hydraulic system will be factory set to a pressure that will smoothly
power the cover doors upward and downward. The system is designed to keep the doors firmly
open when reloading hose as well as to hold the cover doors firmly down in the travel position.
Mechanical locks are not required in order to avoid possible injury from accidental closing of
cover doors.
RFQ (Goods and Services) No.: 1220-41-25-09
72
Hydraulic cylinders, located in front of the hose bed storage area will be utilized to open/close
the cover doors. The hydraulic system shall be powered by a self-contained power unit. The
hydraulic system will be designed so the doors only operate in the predetermined factory-set
sequence. There shall be a manual method of opening and closing the covers should there be
a system failure.
State manual method.
A self-contained switch will be utilized to raise/lower the cover doors. The switch will be located
at the rear of the apparatus in a convenient location allowing the operator to view the hosebed
cover doors while operating the mechanism from ground level. The switch will be the
momentary type of switch that requires the operator to hold the switch until the desired
movement of the cover doors is achieved.
The power unit will be interlocked with the parking brake and shall be operable only when the
park-brake is applied. The doors will be connected to the open door warning system when in
the open condition. An audible alarm will be located towards the front of the hose bed area
designed to warn possible occupants of the hose bed area that door movement is occurring.
Yes ____
No ____
VINYL FLAP ON END OF HOSE BED COVER
There will be a BLACK heavy duty vinyl flap located on the rear of the hose bed cover installed
on the apparatus. The flap will have a weighted bottom edge.
Yes ____
No ____
STORAGE UNDER HOSEBED
There shall be a storage compartment under the hose bed for storing long tools and material.
The storage compartment includes a horizontally hinged chevron striped plate door. The
compartment will also include stops to keep the material from sliding forward. Approximate
dimensions: 56” W x 12” H x 48”/72” deep, there will be a partition at the 48/72 step. The 72”
portion will have a tray with 6 removable dividers. To be determined at the pre-construction
meeting.
Yes ____
No ____
HARD SUCTION STORAGE
There shall be storage for two (2), 10’ x 6” hard suction hoses, to be stacked on the right side of
the main hose bed. Exact mounting and location to be determined at the pre-construction
meeting.
Yes ____
No ____
HOSE WEBBING
There will be a heavy duty 1” x 1” black nylon webbing installed on the rear of the apparatus.
The sides and bottom of the webbing shall be attached by D-rings and hook fasteners. Or
Surrey approved equal.
The final configuration and fastening design shall meet the approval of the Fire Chief.
Yes ____
No ____
WIRING HARNESSES
Wiring harnesses will be the automotive type, engineered specifically for the builder's
apparatus, and will meet the following criteria. Under no circumstances will diodes, resistors, or
fusible links be located within the wiring harness. All such components will be located in an
easy to access wiring junction box or the main circuit breaker area. All wire will meet white
book, baseline advanced design transit coach specification and Society of Automotive
RFQ (Goods and Services) No.: 1220-41-25-09
73
Engineers recommended practices. It will be stranded copper wire core with cross linked
polyethylene insulation complying with SAE specification J1128.
Each wire will be hot stamp function coded every three inches starting one inch from the end
and continuing throughout the entire harness. In addition to function coding, each wire will be
number and color coded.
All terminals on the ends of the wiring harness will be soldered unless a crimping tool or
machine is used that gives an even and precise pressure for the terminal being used. All
terminals will be pull tested to insure their integrity.
Yes ____
No ____
V-MUX ELECTRICAL MANAGEMENT SYSTEM
Prefer the apparatus to be equipped with a V-MUX Multiplex System. The Manufacture of the
Multiplex system will provide at a minimum three cities of reference that have at least 10 trucks
operational for over a one year period. The Multiplex system hardware that is being put into the
apparatus of this bid will be field proven for a minimum of two years. Any multiplex system that
has less then 200 systems in vehicles with less then two years field time on the identical
hardware that will be put into the apparatus shall be excluded from this bid process. Any
Multiplex system with a warranty higher then 1% over the past 2 years will be excluded. There
are several key benefits to multiplexing, one is to reduce the number of connections in a
vehicles electrical system, because of this it is important to limit the amount of modules that
control certain functions of the vehicle, therefore wherever it is stated that an “add-on” module
will not be acceptable, there will be No Exceptions.
Outputs:
The outputs will perform all the following items without added modules to perform any of the
tasks.
1. Load Shedding: The System will have the capability to Load Shed with 8 levels any
output. This means we can specify which outputs (barring NFPA restrictions) we would
like Load Shed. Level 1 12.9v, Level 2 12.5V, Level 3 - 12.1V, Level 4 - 11.7V, Level 5
11.3V, Level 6 10.9V, Level 7 10.5, Level 8 10.1. Unlike conventional load shedding
devices you can assign a level to any or all outputs. Load shedding will be determined at
pre-construction. No add-on modules will be acceptable; the module with the
outputs must perform this function.
2. Load Sequencing: The System will be able to sequence from 0-8 levels any output.
With 0 being no delay and 1 being a 1 second delay, 2 being a 2 second delay and so
on. Sequencing reduces the amount of voltage spikes and drops on our vehicle, and
can help limit damage to our charging system. Load sequencing will be determined at
pre-construction. No add-on modules will be acceptable; the module with the
outputs must perform this function.
3. Output Device: The System will have solid-state output devices. Each solid-state output
shall be a MOS-FET (Metal Oxide Semiconductor - Field Effect Transistors); MOS-FETs
are solid-state devices with no moving parts to wear out. A typical relay when loaded to
spec has a life of 100,000 cycles. The life of a FET is more than 100 times that of a
relay. No add-on modules will be acceptable; the module with the outputs must
perform this function.
4. Flashing Outputs: The System will be able to flash any output in either A or B phase,
and logic is used to shut down needed outputs in park, or any one of several combined
interlocks. The flash rate can be selected at either 80, or 160 FPM. This means any light
can be specified with a multiplex truck with no need to add flashers. Flashing outputs
RFQ (Goods and Services) No.: 1220-41-25-09
74
can also be used to warn of problems. No add-on modules will be acceptable; the
module with the outputs must perform this function.
5. PWM: The modules will have the ability to PWM at some outputs so that a Headlight
PWM module is not needed. No add-on modules will be acceptable; the module
with the outputs must perform this function.
6. Diagnostics: An output will be able to detect either a short or open circuit. The System
will be able report in “real time” a text based message that points the maintenance
person to a specific output.
Inputs:
1. The inputs will have the ability to switch by a ground or battery signal.
2. The inputs will be filtered for noise suppression via hardware and software so that RF or
dirty power will not trick an input into changing its status.
Automatic Climate Control:
The Multiplex system will have the capability to provide automatic climate control, this shall
occur by the use of PWM outputs and a Digital readout that combines other vehicle
functions as well. The Climate control will be an integral part of the Multiplex system. No
add-on modules will be acceptable; the module with the outputs must perform this
function.
Auto-Throttle:
The Multiplex system will be able to perform automatic high idle via a network gateway or by
using an existing output on a module to provide the proper signals to an OEM Engine ECU.
This task will be handled with existing inputs and outputs. No add-on modules will be
acceptable; the module with the outputs must perform this function.
Displays:
Displays will be able to provide real time information regarding Load Shedding and System
Status, such as network traffic/errors or shorts and open circuits.
System Network:
The Multiplex system will contain a Peer-to-Peer network. A Master Slave Type network is
not suitable for the Fire/Rescue industry. A Peer-to-Peer network means that all the
modules are equal on the network; a Master is not needed to tell other nodes when to talk.
System Reliability:
The Multiplex system will be able to perform in extreme temperature conditions, from 40° to
+85° C (-40° to +185° F.) The system will be sealed against the environment, moisture,
humidity, salt or fluids such as diesel fuel, motor oil or brake fluid. The enclosures will be
rugged to withstand being mounted in various locations or compartments around the
vehicle. The modules shall be protected from over voltage and reverse polarity.
Yes ____
No ____
WELDON V-MUX TRANSCEIVER KIT WITH DIAGNOSTICS SOFTWARE
Provide any updates or new equipment available.
Yes ____
RFQ (Goods and Services) No.: 1220-41-25-09
No ____
75
WEATHERPROOF DOOR SWITCHES
Due the harsh environment and susceptibility to moisture on the fire ground, the fire apparatus
compartment doors will utilize weatherproof switches. Two different types of switches will be
used. Weatherproof proximity switches will be utilized where space permits. In tight locations,
mechanical weatherproof switches will be used. No Exceptions.
The switches will be used for activation of the compartment lights and will provide a signal to the
door open circuit in the cab.
Yes ____
No ____
12 VOLT WIRING
All wiring must be concealed or out of harm’s way but must be accessible to any junctions,
relays, end points etc.
Yes ____
No ____
12 VOLT SYSTEM SCHEMATIC
A complete electrical schematic for the apparatus is to be provided. This schematic will be
specifically prepared for this individual unit rather than a generic schematic designed to
accommodate all apparatus.
Yes ____
No ____
12 VOLT SYSTEMS TEST
After completion of the unit, the 12 volt electrical system will undergo a battery of tests as listed
in the latest addition of NFPA Pamphlet 1901. These tests will include, but not be limited to: a
reserve capacity test, alternator performance test at idle, alternator performance test at full load,
and a low voltage alarm test. Certification of the results will be supplied with the apparatus at
the time of delivery.
Yes ____
No ____
REAR WORK LIGHT SWITCH ( REAR - BODY - REVERSE )
There will be a switch at the rear of the apparatus to activate the backup lights when the parking
brake is set. This switching circuit shall be deactivated when the parking brake is released.
There will also be a switch provided in the cab to activate the backup lights when the parking
brake is set. This switching circuit shall be deactivated when the parking brake is released.
In addition to the lights being activated by the above switches, the lights will also come on when
the transmission if placed in reverse.
Yes ____
No ____
MIDSHIP TURN SIGNAL ( LED )
There will be one (1) Truck-Lite model 21LED midship auxiliary / turn signal lights installed in
the rub rail, on each side of the body. Or Surrey approved equal.
Yes ____
No ____
LED CLEARANCE LIGHTS
Truck-Lite model 30 LED clearance lights will be installed on the rear of the body as necessary
to be in full compliance with applicable ICC and DOT codes and regulations. Or Surrey
approved equal.
Yes ____
RFQ (Goods and Services) No.: 1220-41-25-09
No ____
76
GROUND LIGHTING
Truck-Lite model 40 lights will be installed beneath the apparatus in areas where personnel may
be expected to climb on and off of the apparatus. The lights will illuminate the ground within 30"
of the apparatus to provide visibility of any obstructions or hazards. These areas will include,
but not be limited to, cab doors, side running boards, and the rear step area.
Yes ____
No ____
WALKWAY LIGHTS
Grote 60571 LED lights will be mounted in a manner that illuminates all walkways and steps for
safe operation of the apparatus. These lights will become illuminated when the parking brake is
engaged.
Yes ____
No ____
SIGTRONIC US-67S INTERCOM
There will be a Sigtronics US-67S intercom system supplied and installed on the apparatus.
The system will have the following capabilities:
Drivers Position
Officers Position
Four (4) Crew Positions
Intercom / PTT
Intercom / PTT
Intercom
The following accessories shall be provided: One (1) radio adapter interfaces, four (4) SE-8
headsets.
Radio Interface to be for a M/A COM model #D28LTX
Yes ____
No ____
REAR STEP SIGNAL SYSTEM
A rear step buzzer system will be installed. It will consist of one (1) weather proof button at the
rear step area with a label reading "1-STOP, 2-GO, 3-BACK UP", and a buzzer in the cab that is
activated by the rear step switch.
Yes ____
No ____
ON-SCENE SOLUTION LED COMPARTMENT LIGHTING
All high side compartments will be furnished with an On-Scene Solution LED compartment light
mounted on the front corner of the compartment. An automatic door switch will activate these
compartment lights.
All full height compartments will be equipped with an On-Scene Solution LED compartment light
mounted on the front corner of the compartment. An automatic door switch will activate these
compartment lights.
All compartments that have a door opening larger than 42" wide will have an "On-Scene" LED
compartment light installed on the front and rear corner of the compartment.
Further, lighting will be installed in any compartment or enclosed, equipment area with four
cubic feet of storage capacity or greater, or any compartment with a door opening of 144 square
inches or more.
Each compartment shall contain two (2) light strips.
Yes ____
RFQ (Goods and Services) No.: 1220-41-25-09
No ___
77
PUMP COMPARTMENT LIGHTS
There will be two (2) lights installed in the pump compartment. The lights will be activated by an
automatic switch in the right side pump compartment access door and will be located in a
manner that will provide maximum lighting.
Yes ____
No ____
TAIL LIGHTS
There will be two (2) Whelen 600 series LED tail light assemblies installed on the rear of the
apparatus. Two (2) red LED tail/brake lights, two (2) amber LED turn lights, and two (2) white
LED reverse lights will be supplied. The lights will be mounted in a cast housing, on each side
of the apparatus.
Yes ____
No ____
12 VOLT SCENE LIGHTS
There will be five (5) Whelen 70K000ZR with 7E flange, Opti-Scenelight with 8-32 degree optics
installed on the apparatus.
One (1) light shall be located on the upper rear face of cab for the illumination of the Crosslay
Hose Beds & Dunnage area.
This light shall be switched on the Pump Operator's panel and shall be one of the earliest lights
to shed through the Multiplex system. Shedding point to be determined at pre-construction
Locate two (2) scene lights on the left side of the body, (1) to the front and (1) toward the back
Locate two (2) scene lights on the right side of the body, (1) to the front and (1) toward the back.
These lights shall be switched by the V-Mux and when a cab door on the corresponding side is
open.
Yes ____
No ____
12 VOLT SCENE LIGHTS
There will be two (2) Whelen 810CA0ZR scene light with 8-32 degree optics installed on the
apparatus.
The lights shall be located at the upper rear of the apparatus (1) each side above the amber
warning lights.
The rear scene lights will be controlled by the V-Mux, rear work light switch, and when the
transmission is placed in reverse.
Yes ____
No ____
CUSTOMER SUPPLIED ANTENNAS
There will be two (2) customer supplied antennas shipped to the manufacturer for installation.
One (1) GPS antenna mounted on the cab roof right side. One (1) radio antenna mounted on
the cab roof left side.
Yes ____
No ____
CAB INTERIOR SPEAKER WIRING
There shall be speaker wiring 16/2 from the centre top rear of the cab with a one foot pig tail,
routed to the dash electrical centre cover with a three foot pig tail
Yes ____
No ____
LAPTOP COMPUTER DOCK
A Gamber Johnson NP-PANDOCK-L docking station c/w MCS-CLEVIS, and 7160-0095 LED
light assembly will be installed. Exact location to be determined at the pre-paint meeting.
Yes ____
RFQ (Goods and Services) No.: 1220-41-25-09
No ____
78
PANASONIC CF30 TOUGHBOOK
Supply one (1)
CF30KQPAXAM Intel ® Core™ 2 Duo Processor SL9300 1.6 GHz, 13.3" TFT (AR.T/S)
160 GB SATA HDD, 2GB, 802.11 a/b/g, Bluetooth 2.0, (No FDD),
Dual Connector, Wireless Antenna, Genuine Windows ® XP Pro
SP2, VISTA License included (Vista/XP Recovery Disks included)
Yes ____
No ____
ONAN HYDRAULIC GENERATOR SET
An Onan model CMHG 8000, hydraulic driven generator set will be installed on the apparatus in
the upper dunnage area. The generator will be rated at 8,000 watts at 120/240 volts. Current
frequency will be stable at 60 hertz.
The power generating unit will be modular unit, housed in stainless steel with an acoustical
material added for maximum sound dampening. The module will consist of the hydraulic motor,
generator, blower, cooler, and all other necessary components.
For ease of maintenance, the only part of the system that will require accessibility shall be the
oil reservoir which will be located as to facilitate periodic checks and the adding of hydraulic
fluids.
Yes ____
No ____
WARRANTY PERIOD
Provided such goods are operated and maintained in accordance with Onan's written
instructions, Onan warrants that the CMHG SERIES Hydraulic Generators will be free from
defects in material and workmanship for a period of five (5) years or one thousand (1,000)
hours, whichever comes first, from the date of delivery to the first purchaser.
Repair or replacement parts will be warranted for ninety (90) days from date of purchase,
excluding labor and travel expenses. Any part repaired or replaced during the warranty period
assumes the remainder of the warranty or ninety (90) days, whichever is greater.
Onan will pay for the parts and labor, including diagnostic labor, to repair the generator. When
necessary, Onan will also pay reasonable labor expenses associated with the removal and
reinstallation of the generator into the customer's equipment, up to the maximum time of two (2)
hours. For the first two (2) years of coverage, Onan will pay travel time up to two and one-half
(2.5) hours and mileage cost up to one hundred (100) miles, if such work is done by an Onan
distributor or other service representative designated by Onan.
The generator shall be located in the forward portion of the hosebed.
Yes ____
No ____
GENERATOR HOT SHIFT PTO CONNECTION
The hydraulic pump for the generator system will be connected to the chassis transmission
through a "Hot Shift", electrically engaged power-take-off system. The control to engage and
disengage the power-take-off system will be installed in the chassis cab.
Yes ____
RFQ (Goods and Services) No.: 1220-41-25-09
No ____
79
FROG DISPLAY
There will be a FROG D provided with the generator. The FROG D will automatically sense a
generator signal and begin displaying information. The digital meter display will constantly
monitor and display Voltage, Frequency (accurate to within 1 decimal point), and Current Draw
on two separate lines. The display will be capable of displaying total accumulated run time
hours when the MODE button is pressed. This information will be stored in a non-erasable
memory.
The frog display shall be located on the pump panel.
Yes ____
No ____
GENERATOR COVER
A treadplate cover will be installed over the generator. The cover will be designed in such a
manner as to allow for easy access to the generator when performing routine maintenance.
The cover will also be designed in compliance with the generator manufacturer's air flow
requirements.
Yes ____
No ____
GFI LOAD CENTER
The entire 120 volt electrical system will be installed in strict compliance with NFPA Pamphlet
1901, newest edition. This will include all testing, labeling, wiring methodology, and dimensional
requirements. Certification of compliance will accompany the apparatus at the time of delivery.
There will be a 120 volt load center incorporated into the 120 volt wiring system. The load
center will include adequate circuit breakers to protect the loads specified on this apparatus.
All 120 volt A.C. Wiring will be done in accordance with NFPA Pamphlet 1901 as well as
nationally accepted electrical codes.
Yes ____
No ____
BRANCH CIRCUIT OVERCURRENT PROTECTION
Overcurrent protection devices will be provided for circuits in accordance with NFPA 1901
newest version. The load center will be equipped with a non-GFI two pole main breaker when
the six or more individual branch circuits are present.
Overcurrent protection devices will be marked with labels to identify the function of the circuit
they protect.
The load center shall be located L1 compartment against the forward wall.
There shall be a drip pan with drain provided in the upper section of the compartment. The drip
pan shall prevent moisture from the roll-up door spool from coming in contact with the breaker
box.
Yes ____
No ____
ELECTRIC CORD REEL
There will be one (1) Hannay 120 volt electric rewind cord reel model ECR1616-17-18 installed
on the apparatus with a push button labeled REEL REWIND installed for 12 volt rewinding of
each cord reel. The reel will be equipped with 200' of yellow STW Seoprene 105 degree
Celsius 10/3 wire installed with a cable stop to prevent damage to cable fittings. Rollers will be
supplied to prevent damage to the electrical cable if pulled in any direction.
The 120V Cord Reel shall be located in the upper portion of R1 compartment. Exact location to
be determined at pre-construction meeting.
Yes ____
RFQ (Goods and Services) No.: 1220-41-25-09
No ____
80
CORD REEL JUNCTION BOX
There will be one (1) Extenda-Lite model EJB-CS back lighted electrical junction box, equipped
with four (4) electrical receptacles, two on each side. Each receptacle will be equipped with a
spring loaded snap cover. A cord reel will be prewired to the cast aluminum junction box to
supply power to the four receptacles. An extension cord will be connected to the junction box
through a heavy duty water resistant strain relief and flexible extender. Each side of the junction
box will be fitted with polypropylene faceplates which are back lighted so that plug orientation to
the receptacles is quick and easy to align.
The receptacles shall be 15 amp U ground style.
Yes ____
No ____
SHADOW-RT LIGHT TOWER
The apparatus will be equipped with one (1) Command Light, Shadow-RT, model SL445-RT, all
electric floodlight tower. The unit will not require tapping into vehicle braking system to be
operated, eliminating the chance for vehicle brake problems. Hydraulic or pneumatic type
floodlights will not acceptable alternatives to the all electric light tower specified.
The light tower shall have 4 weatherproof, 500 watt, 120 volt quartz halogen lights. Light heads
shall be mounted in a cluster to provide maximum illumination.
The light tower shall be capable of elevating to 90 degrees (full upright) then past to 135
degrees to provide illumination over the side of the vehicle, no exceptions.
The light tower shall be capable of 350 degrees rotation. Further the tower shall automatically
return to the proper position when autopark is initiated, no exceptions.
Light tower will be controlled with a hand-held umbilical line remote control. The controls on the
remote box shall be:
1.
2.
3.
4.
5.
6.
Two (2) switches, one (1) for each light bank.
One (1) switch for elevating / retracting the arm.
One (1) switch for rotation of the light bank.
One (1) switch to engage autopark.
One (1) indicator light to indicate when light bank is out of roof nest position.
One (1) indicator light to indicate when light bank is rotated to proper nest position.
The controls will be located in the L1 compartment.
The light tower will have a full extension over 3 feet from mounted position and extend from nest
position to full upright in 15 seconds. The overall size of nested light tower will be approximately
24" wide x 42" long x 10" high, and weight approximately 50 lbs.
The light tower will be all aluminum construction, with stainless steel shafts and bronze
bushings for long life and low maintenance.
The light tower shall be mounted perpendicular to the rear wall of the cab on the raised roof
portion with the lighthead portion to the front when in the stored position.
Yes ____
No ____
Yes ____
No ____
LED WARNING LIGHTS
All LED warning lights are to be SUPER LED
RFQ (Goods and Services) No.: 1220-41-25-09
81
UPPER ZONE A VISUAL WARNING
There will be one (1) Whelen Engineering model FL2RRBB9LLTH82, 82" long light bar installed
on the chassis cab roof. The lightbar will be equipped with two (2) forward facing linear12
Super "White" LED's, two (2) forward facing linear12 Super "Red" LED's, four (4) corner
forward facing "Red" LED's, and two (2) side facing Halogen Alley Lights.
There will be an Opticom located in the center of the lightbar.
The lightbars will be equipped with red lenses.
Lightbar includes Opticom Emitter #9592.
Yes ____
No ____
UPPER ZONE C VISUAL WARNING
There will be two (2) Whelen Engineering model L31HRFN beacon installed high at the rear of
the apparatus. The left side beacon to be fast flash, the right side beacon to be standard flash.
The beacons will have red lenses.
The hatch compartment is to be notched to allow the beacon to be lowered.
Yes ____
No ____
UPPER ZONE C VISUAL WARNING
There will be two (2) Whelen 600 series LED lights installed in the upper warning zone. The
lights will have amber lenses.
Locate below the scene lights.
Yes ____
No ____
LOWER ZONE B VISUAL WARNING
There will be three (3) Whelen 600 series LED lights with flanges installed in the lower warning
zone. The lights will have red lenses.
Yes ____
No ____
LOWER ZONE C VISUAL WARNING
There will be two (2) Whelen 600 series LED lights with flanges installed in the tail light
housings. The lights will have red lenses.
Yes ____
No ____
LOWER ZONE D VISUAL WARNING
There will be three (3) Whelen 600 series LED lights with flanges installed in the lower warning
zone. The lights will have red lenses.
Yes ____
No ____
Yes ____
No ____
AIR HORN BUTTON ON PUMP PANEL
One (1) air horn button will be provided on the pump panel.
WHELEN 700 SERIES GRILLE LED
There will be one (1) Whelen 700 series LED light installed on the front of the cab. The LED
light will be wired in such a manner as to be disabled when the parking brake is set. A switch in
the main switch panel will control the unit in conjunction with the parking brake circuit.
Locate either on or above the front grille.
Yes ____
RFQ (Goods and Services) No.: 1220-41-25-09
No ____
82
BODY COMPARTMENTATION COATING
The interior of the body compartments will be coated with a gray (preferred) thermo-plastic
polyurethane coating. The coating will be durable enough to withstand everyday abuse of
equipment removal and shifting.
Yes ____
No ____
PUMP COMPARTMENT - JOB COLOR
The pump, valves, plumbing and interior of the pump compartment will be painted with PPG
polyurethane enamel paint. The paint will be job color, same as the body or Black.
Yes ____
No ____
APPARATUS BODY COLOR
The apparatus will be painted with High Solids Polyurethane Base/Clear Coat.
The apparatus will be painted (RED) PPG# FBCH - 75380 alt
Yes ____
No ____
TOUCH UP PAINT
One (1) four ounce bottle of acrylic enamel touch-up paint will be supplied for each colour.
Yes ____
No ____
REFLECTIVE LETTERING
There will be forty two (42) reflective letters provided and installed on the apparatus. The letters
will be approximately 4" tall with black outline and shadow.
Lettering to be applied as follows in gold reflective with black shade in Symbol ITC (Roman)
font.
"FIRE RESCUE" to be applied to the front of the cab with "FIRE" on RH and "RESCUE" on LH.
"FIRE RESCUE" to be on L2/R2 in the 4" White stripe.
"CITY OF SURREY" on LH upper body.
Yes ____
No ____
REFLECTIVE 6" FLAG - STRAIGHT
There shall be two (2) 6" reflective Canadian Flags installed on the apparatus.
The flags shall be located above the front cab doors ahead of the 810 scene light.
Yes ____
No ____
NFPA COMPLIANT REFLECTIVE STRIPING
Reflective striping will be applied to the exterior of the apparatus in a manner consistent with the
National Fire Protection Association Pamphlet 1901, latest edition. It will consist of a 1", 4", and
a 1" wide stripe low across the front of the chassis and along the sides up to the first
compartment on each side where it shall then angle up and back to a point above the wheel well
area where it shall then run level to the back edge of the body. There will be a 1" gap provided
between each of the stripes. A 6" wide, red/yellow chevron stripe will be applied across the rear
of the apparatus. To be determined at pre-construction meeting.
Yes ____
No ____
UNDERCOATING
The apparatus is to undergo an undercoating process. During this application, special care will
be taken to avoid spraying the product on air lines, cables, or other items that would cause
normal maintenance to be hindered.
State process for undercoating:
Yes ____
RFQ (Goods and Services) No.: 1220-41-25-09
No ____
83
MUD FLAPS
Four (4) mud flaps will be installed on the apparatus, two at the front and two at the rear. The
mud flaps will be a minimum of 3/8" thick to prevent "sailing".
Yes ____
No ____
WORDEN RUBBER WHEEL CHOCKS
One (1) pair of Worden HRC rubber wheel chocks will be provided with the apparatus (send
loose).
Yes ____
No ____
ELECTRONIC SIREN
There will be one (1) Federal model PA300MSC electronic siren installed in the cab. Full
features of the siren will include Wail, Yelp, Hi -Lo, Air Horn, and a hard-wired microphone.
The siren will be flush mounted in the center console on the officer’s side of center.
Yes ____
No ____
CUSTOMER SUPPLIED 2-WAY RADIO
Customer supplied 2-way radio will be flush mounted in the center console on the officer’s side
of center above the electronic siren.
Yes ____
No ____
OEM PAINTED CHASSIS RIMS
The chassis rims will be as painted from the chassis manufacturer. White.
Yes ____
No ____
FUEL FILL
There will be a fuel fill pocket located in the right rear wheel well area. The fuel fill will have a
Cast Products aluminum door with bezel installed.
Yes ____
No ____
FUEL TANK SENDING UNIT ACCESS PANEL
There will be a removable panel provided in the rear compartment to allow for access to the fuel
tank sending unit without removing the fuel tank.
Yes ____
No ____
CENTER FRONT STORAGE WELL IN BUMPER
There will be a storage well in the extended front bumper. The well will be located in the center
over the chassis frame rails, and will be as large as practical to accommodate 150 ft of 1 ½” fire
hose. There shall be a 2” lip along the front of the compartment to help retain the fire hose.
The floor will be covered with removable interlocking tiles.
Yes ____
No ____
FRONT BUMPER HOSE COMPARTMENT COVER
There will be one (1) aluminum treadbrite cover installed on the front bumper hose
compartment.
Yes ____
No ____
BUS STYLE MIRROR
There will be a stainless steel bus style mirror installed on the right side roof of the cab. The
mirror will allow the driver to see down the front and side of the vehicle for added security.
Mirror is to be installed on the right front corner of the cab, to view the front bumper area.
Yes ____
RFQ (Goods and Services) No.: 1220-41-25-09
No ____
84
AXE BRACKET
There will be two axe mounting brackets located on the apparatus. Exact location and design to
be determined at pre-construction meeting.
Locate on the front surface of the fire body, one (1) each side.
Yes ____
No ____
PINCH POINT CROW BAR BRACKET
Supply one (1) Akron PPBH, raised mount, pinch point bar holder set. Ship loose.
Yes ____
No ____
Yes ____
No ____
WHEEL COVERS
Install Spartan supplied nut covers.
MANUFACTURING LABELS
A permanent plate will be mounted in the driver's compartment specifying the quantity and type
of the following fluids that may be used in the apparatus for normal maintenance. Where a fluid
is not applicable to the unit, the plate will be marked N/A to inform the service technician who
may not be familiar with the apparatus.















Engine oil
Engine coolant
Transmission fluid
Pump transmission fluid
Pump primer fluid
Drive axle fluid
Air conditioning refrigerant
Power steering fluid
Cab tilt mechanism fluid
Transfer case fluid
Equipment rack fluid
Air compressor system lubricant
Generator system lubricant
Front tires air pressure
Rear tires air pressure
A permanent plate will be affixed in the driver's area that states the maximum number of
personnel allowed to ride on the apparatus at any time.
A sign will be affixed in the chassis cab, in plain sight of the driver that states the overall travel
height, overall length, and gross GVWR of the apparatus.
On any gated inlet on the apparatus, a permanent label will be provided that states:
"WARNING: Death or serious injury might occur if proper operating procedures are not followed.
The pump operator as well as individuals connecting supply or discharges hoses to the
apparatus must be familiar with water hydraulics hazards and component limitations."
All other appropriate labels to ensure safe operation of the apparatus will be permanently affixed
in conspicuous locations.
Yes ____
RFQ (Goods and Services) No.: 1220-41-25-09
No ____
85
EQUIPMENT SUPPLIED WITH TRUCK
Per vehicle;


One (1) 270 amp Leece Neville 12 volt alternator
One (1) Retrac, West Coast style mirrors model 1171HL
Yes ____
RFQ (Goods and Services) No.: 1220-41-25-09
No ____
86
SCHEDULE B
GENERAL TERMS AND CONDITIONS
PURCHASE TWO (2) ONLY 7000 L.P.M. TRIPLE COMBINATION PUMPER UNITS
REFERENCE No.: 1220-41-25-09
RFQ (Goods and Services) No.: 1220-41-25-09
87
SCHEDULE B – GENERAL TERMS AND CONDITIONS
DEFINITIONS AND INTERPRETATION
1.
In these General Terms and Conditions:
(a)
(b)
(c)
(d)
(e)
2.
"Agreement" has the meaning set out in Section 2;
“City” means the City of Surrey;
“Contractor” means a contractor whose Quotation has been accepted by the City
and who is supplying the Goods under this Agreement;
“Goods” means the equipment or materials that are the subject of this Agreement;
and
“Purchase Price” means the price quoted by the Contractor and accepted by the
City, unless otherwise agreed by the parties in writing, and includes all taxes,
duties, freight charges and other charges except PST and GST.
This Agreement may be modified only by express and specific written agreement. In the
event of a conflict between the provisions of any documents listed below, then the
documents shall govern and take precedence in the following order:
(a)
(b)
(c)
(d)
(e)
these General Terms and Conditions;
the specifications set out in Schedule A of the Request for Quotations ("RFQ");
the RFQ;
the Quotation; and
other terms, if any, that are agreed to by the parties in writing.
GOODS
3.
The Contractor will supply the Goods in accordance with this Agreement. The Goods
supplied will meet the specifications set out in Schedule A of the RFQ and as described in
the Quotation set out in Schedule C of the RFQ.
4.
The Contractor will deliver the Goods free and clear of all liens and encumbrances in the
manner and to the destination stipulated. In the event of the Contractor's failure to meet
this condition, the Contractor will, on written notice from the City, forthwith return all
monies paid by the City on account of the Goods and in addition the City may by written
notice terminate this Agreement without liability, and in such event, in addition to the
above, the Contractor will be liable for any and all expenses or losses incurred by the City
resulting from such failure.
PURCHASE PRICE
5.
The City will pay the Purchase Price to the Contractor in accordance with this Agreement.
The Purchase Price shall also include without limitation all costs of boxing, packing,
crating, and loading and unloading the Goods at the prescribed destination.
TIME
6.
The Contractor acknowledges that time is of the essence with respect to the provision of
the Services and accordingly the Contractor will provide the Services within the
performance or completion dates or time periods (the "Time Schedule") as set out in
this Agreement, or as otherwise agreed to in writing by the City and the Contractor. If at
RFQ (Goods and Services) No.: 1220-41-25-09
88
any time the Contractor discovers that the Time Schedule cannot be met it will
immediately advise the City in writing and provide a revised Time Schedule.
PAYMENT
7.
Invoices must include the Contractor's name, address and telephone number, the City's
purchase order number, the Contractor's invoice number, the Contractor's GST
registration number or an indication that it is not applicable if the Contractor is a small
trader, the quantity, tax (if any) and the complete Purchase Price calculations, including
extensions and discounts.
8.
The City will pay the invoice, in the amount as the City determines is correct less any
deductions for setoffs or holdbacks permitted by this Agreement including, without
limitation, those described in Sections 10, 11 and 12, within 30 days of the receipt of the
invoice, unless the parties have agreed in writing to other payment terms. The payment
by the City of any invoice will not bind the City with respect to any subsequent payment or
final payment and will not mean that the City has accepted that the Goods are in
accordance with the requirements of this Agreement, or that the Contractor is in any
manner released from its obligation to comply with this Agreement.
9.
Unless otherwise provided, all dollar amounts referred to in this Agreement are in lawful
money of Canada.
DEFICIENCIES
10.
The City shall have a reasonable time to inspect and to accept the Goods. The City may
reject any Goods not in accordance with this Agreement, whether due to damage resulting
from improper packing, loading, unloading or otherwise. The City shall notify the
Contractor of rejection of the Goods whereupon the Goods will be held subject to the
disposition by the Contractor. Any costs or expenses incurred by the City as a result of
the rejection of the Goods are, immediately upon written demand by the City, payable by
the Contractor, and may be set off against any payments owing by the City to the
Contractor.
11.
The City may hold back from payments otherwise due to the Contractor up to 150% of a
reasonable estimate, as determined by the City, on account of deficient or defective
materials. This holdback may be held, without interest, until replacement Goods are
received or such deficiency or defect is remedied.
DEFAULT AND TERMINATION
12.
In the event the Contractor does not ship the Goods by the shipping date specified in this
Agreement, or does not deliver the Goods by the delivery date specified in this Agreement,
or otherwise fails to comply with the requirements of this Agreement, then:
(a)
the City reserves the right to terminate this Agreement, in whole or in part, and in
the event of such termination no payment will be owing by the City on account of
this Agreement and the Contractor will be liable for any and all expenses or loss
resulting from such failure or delay and will return all monies paid by the City; or
RFQ (Goods and Services) No.: 1220-41-25-09
89
(b)
if the City does not terminate this Agreement for late shipping or delivery, the City
may deduct and setoff from any payments owing to the Contractor all additional
costs the City reasonably incurs on account of the late shipping or delivery.
13.
The City may by written notice at any time cancel this Agreement with respect to Goods
which, as of the date of cancellation, have not been shipped.
14.
If the Contractor becomes insolvent or makes an assignment for the benefit of creditors or
a receiver or trustee is appointed for the property of the Contractor, then the City may, at
its election, and without prejudice to its rights at law or in equity, terminate this Agreement.
15.
The City will not accept nor be responsible for any restocking charges for any Goods
shipped to the City and then, for whatever reason, returned to the Contractor pursuant to
this Agreement. The Contractor is to bear all costs including shipping and handling of
returned Goods.
WARRANTIES AND INDEMNITIES
16.
The Contractor warrants that the Goods shall be free from defects in design, materials,
workmanship and title, shall conform in all respects to the terms of this Agreement, shall
be fit and suitable and perform satisfactorily for the purposes and under the conditions
made known to the Contractor by the City or which were reasonably inferable. The Goods
shall be at least equal to the higher of national standards or codes (such as, by way of
illustration, CSA or ASTM), or standards and codes customarily applicable at the place
where the City will use the Goods. The Goods shall be of the best quality, if no quality is
specified. This general warranty is independent of and without prejudice to any specific
warranty or service guarantee offered by the Contractor or third party manufacturer or
supplier of the Goods in connection with the purpose for which the Goods were
purchased. The Contractor shall assign to the City any warranty or service guarantee
offered by a third party manufacturer or supplier of the Goods. Notwithstanding this
assignment, if at any time up to one year from the date of delivery or installation (if
applicable) the City determines the Goods or any part do not conform to these warranties,
the City shall notify the Contractor within a reasonable time after such discovery, and the
Contractor shall then promptly correct such nonconformity at the Contractor's expense.
Goods used to correct a nonconformity shall be similarly warranted for one year from the
date of installation. The Contractor's liability shall extend to all liabilities, losses, damages,
claims and expenses incurred by the City caused by any breach of any of the above
warranties.
17.
The Contractor warrants and guarantees that Goods delivered under this Agreement do
not infringe any valid patent, copyright or trademark, foreign or domestic, owned or
controlled by any other corporation, firm or person, and agrees to indemnify and save
harmless the City and all of its elected and appointed officials, officers, employees,
servants, representatives and agents (collectively the "Indemnitees"), from and against
any and all claims, demands, causes of action, suits, losses, damages and costs,
liabilities, expenses and judgments (including all actual legal costs) by reason of any
claim, action or litigation arising out of any alleged or actual infringement of any patent,
copyright or trademark, foreign or domestic, relating to the Goods supplied under this
Agreement.
RFQ (Goods and Services) No.: 1220-41-25-09
90
18.
The Contractor represents and warrants that all Goods delivered under this Agreement
shall comply with all applicable codes, statutes, by-laws, rules and regulations, of any
federal, provincial, municipal or other competent authority for the time being in force,
including any environmental laws and that the Goods are not dangerous to the
environment or to person or health.
19.
The Contractor will indemnify and save harmless the Indemnitees from and against all
claims, demands, causes of action, suits, losses, damages and costs, liabilities, expenses
and judgments (including all actual legal costs) for damage to or destruction or loss of
property, including loss of use, and injury to or death of any person or persons which any
of the Indemnitees incur, suffer or are put to arising out of or in connection with any failure,
breach or non-performance by the Contractor of any obligation of this Agreement, or any
wrongful or negligent act or omission of the Contractor or any employee or agent of the
Contractor.
CUSTOMS
20.
Documentation for shipments of Goods from outside Canada shall be provided by a
Contractor by airmail and shall include all documents as required by law or customary
practice. All packages shall be marked as follows:
"Upon arrival, please contact customs broker:
Livingston International Inc.
Telephone: 604-685-3555
Fax: 604-605-8231
Email: cst19@livingstonintl.com"
INSPECTIONS
21.
If this Agreement pertains to the fabrication, assembly or other processing of the Goods,
representatives of the City shall be permitted free access at all reasonable times for the
purpose of inspection, testing or obtaining information as to the progress of the fabrication,
assembly or processing.
SAFETY
22.
If this Agreement includes any inspection, installation or other work on the City's premises
by the Contractor, or representative or subcontractor of the Contractor, all such activity
shall be performed and undertaken in strict compliance with all applicable health and
safety laws and regulations, including, without limitation, the Workers Compensation Act,
the Occupational Health & Safety Regulation and the Hazardous Products Act, and also in
strict compliance with any published and issued by the City for use at the City's premises.
The Contractor shall provide the City with the Contractor's Workers Compensation Board
registration number and a letter from the Workers Compensation Board confirming the
supplier is registered in good standing with the Workers Compensation Board and that all
assessments have been paid to the date thereof prior to the City having any obligation to
pay monies under this Agreement.
RFQ (Goods and Services) No.: 1220-41-25-09
91
WHMIS/MSDS
23.
The Contractor covenants and agrees to comply with all the Workers Compensation Board
Occupational Health and Safety Regulations for hazardous materials and substances, and
in particular with the "Workplace Hazardous Materials Information Systems (WHMIS)"
Regulations. All "Material Safety Data Sheets (MSDS)" will be shipped along with the
Goods and any future MSDS updates will be forwarded.
SHOP DRAWINGS
24.
The City may require that shop drawings be submitted by the Contractor for review prior
to the delivery of the Goods. The City may require that a qualified registered
professional engineer stamp and approve a shop drawing prior to submission. Any
review of shop drawings by the City will not relieve the Contractor from its obligation to
deliver Goods in full compliance with all requirements of this Agreement.
WAIVER
25.
Any failure of the City at any time or from time to time to enforce or require the strict
keeping or performance of any of the terms and conditions contained in this Agreement
shall not constitute a waiver of the terms and conditions and shall not affect or impair the
terms or conditions in any way or the City's right at any time to avail itself of any
remedies as the City may have for any breach or breaches of the terms and conditions.
APPLICABLE LAW
26.
This Agreement shall be governed by and construed in accordance with the laws of the
Province of British Columbia. The City and the Contractor accept the jurisdiction of the
courts of British Columbia and agree that any action under this Agreement shall be
brought in such courts.
NOTICES
27.
Any notice, report or other document that either party may be required or may wish to give
to the other must be in writing, unless otherwise expressly provided for, and will be
deemed to be validly given to and received by the addressee:
(a)
(b)
(c)
by hand, on delivery;
by facsimile, on transmission; or
by mail, five calendar days after posting.
The addresses for delivery will be as shown in Schedule C to the RFQ. In addition, the
City may give notice to the Contractor by email at the Contractor's email address as
shown in Schedule C to the RFQ, which email will be deemed to be validly given and
received by the Contractor on transmission. The Contractor may not give notice to the
City by email.
RFQ (Goods and Services) No.: 1220-41-25-09
92
MERGER AND SURVIVAL
28.
The representations, agreements, covenants and obligations set out in this Agreement,
including without limitation Section 19, shall survive the delivery of the Goods and
payment of the Purchase Price.
ENTIRE AGREEMENT
29.
This Agreement, including any other documents expressly included by reference in this
Agreement, contains the entire agreement of the parties regarding the provision of the
Goods, and no understandings or agreements, oral or otherwise, exist between the parties
except as expressly set out in this Agreement. This Agreement supersedes and cancels
all previous agreements between the parties relating to the Goods.
RFQ (Goods and Services) No.: 1220-41-25-09
93
SCHEDULE C
FORM OF QUOTATION
PURCHASE TWO (2) ONLY 7000 L.P.M. TRIPLE COMBINATION PUMPER UNITS
REFERENCE No.: 1220-41-25-09
RFQ (Goods and Services) No.: 1220-41-25-09
94
SCHEDULE C
FORM OF QUOTATION
RFQ Title: TO PURCHASE TWO (2) ONLY 7000 L.P.M. TRIPLE COMBINATION PUMPER UNITS
RFQ #:
1220-41-25-09
CONTRACTOR
CITY OF SURREY
Legal Name: ______________________________________
City’s Representative: Manager, Purchasing & Payments
________________________________________________
Address: 6645 – 148 St., Surrey, BC V3S 3C7 CANADA
Address: _________________________________________
Phone: 604-590-7272
Fax: 604-599-0956
Phone: __________________ Fax: __________________
Email: ___________________________________________
1.
The Contractor offers to supply to the City of Surrey the Goods for the prices plus applicable taxes as
follows:
A.
Fire Apparatus Timetable: Number of days from the date of receipt of order to guaranteed delivery date
________ days.
Year: _________________
Make: __________________
Model: ___________________
All costs to meet the minimum specifications shall be included in the following delivered prices.
PARTICULARS
COST PER UNIT
NUMBER OF
UNITS
AMOUNT
CASH PRICE PER UNIT:
$ ______________
X2
$ ___________________
ENVIRONMENTAL LEVY
(BATTERY(IES)):
$ ______________
X2
$ ___________________
TIRE STEWARDSHIP B.C. (TSBC)
LEVY:
$_______________
X2
$ ___________________
AIR CONDITIONING SURCHARGE:
$ ______________
X2
$ ___________________
SUB TOTAL:
$ ___________________
GST: (5%) on $ _________________
=
$ ___________________
PST: (7%) on $ _________________
=
$ ___________________
TOTAL QUOTATION PRICE
(CANADIAN CURRENCY)
$
The above price includes and covers duties, Federal, (including G.S.T.), BC Provincial Sales Taxes, handling
and transportation charges (including duty and brokerage fees), and all other charges incidental to and
forming part of this Quotation.
B.
DELIVERY
F.O.B. Destination, Freight Prepaid to:
Surrey Fire Hall #9, 14901 – 64th. Avenue, Surrey, British Columbia,
V3S 1X8, CANADA.
RFQ (Goods and Services) No.: 1220-41-25-09
95
C.
PAYMENT SCHEDULE
Subject to the provisions of the Agreement documents, and in accordance with legislation and statutory regulations,
the City will make sequenced payment(s) upon performance and the City receiving appropriate progress
documentation, in arrears, and after receipt of an Invoice in accordance with the following:
(1)
First (1st) Payment [Value of Main Fire Pump]:
Payment of a sum equal to the stated value of the Main Fire Pump unit(s) subject to:
(a)
the Contractor providing the City with satisfactory proof of receipt & payment of the Main Fire
Pump; and,
(b)
the City receiving appropriate progress documentation [identified marking, serial number and
notarized documentation] supporting the request for payment.
A total amount not greater than ______________________________ Canadian Dollars
($_________________), plus GST & PST.
(2)
Second (2nd) Payment [Value of Chassis]:
Payment of a sum equal to the stated value of the chassis unit(s) subject to:
(a)
the Contractor providing the City with satisfactory proof of receipt & payment of the chassis;
(b)
the registration card containing the new vehicle information statement;
(c)
receipt of a completed B.C. Motor Vehicle registration form APV-9T; and,
(d)
receipt of a Bill of Sale for the prescribed vehicle from the manufacturer to the City.
A total amount not greater than ______________________________ Canadian Dollars
($_________________), plus GST & PST.
(3)
Third (3rd) Payment [Balance Owing]:
A total amount not greater than ____________________________________
Canadian Dollars
($_________________), plus GST & PST, as may be applicable to such payment; will be made upon
delivery to the City and final inspection, final certification and acceptance by the City, except the City may
hold back from payment(s) 10% of any amount the City determines is payable to the Contractor until such
time as the Contractor provides its final documentation to the City, and satisfactory completion/correction of
any deficiencies.
D.
PAYMENT TERMS
A cash discount of _______% will be allowed if account is paid within _____ days, or the_________ day of the month
following, or net 30 days, on a best effort basis.
2.
If this offer is accepted by the City, such offer and acceptance will create a contract as described in:
(a)
the RFQ;
(b)
the specifications set out above and in Schedule A of the RFQ;
(c)
the General Terms and Conditions; and
(d)
this Quotation; and
(e)
other terms, if any, that are agreed to by the parties in writing.
RFQ (Goods and Services) No.: 1220-41-25-09
96
3.
Capitalized terms used and not defined in this Quotation will have the meanings given to them in the RFQ.
Except as specifically modified by this Quotation, all terms, conditions, representations, warranties and
covenants as set out in the RFQ will remain in full force and effect.
4.
In addition to the warranties provided in the General Terms and Conditions this offer includes the following
warranties:
5.
I/We have reviewed the General Terms and Conditions. If requested by the City, I/we would be prepared to enter
into an agreement that incorporates the General Terms and Conditions, amended by the following departures
(list, if any):
Section
Departure / Alternative
6.
The Contractor confirms that this Quotation will be open for acceptance by the City until ________________.
7.
I/We the undersigned duly authorized representatives of the Contractor, having received and carefully reviewed
the RFQ including without limitation the Specifications and the General Terms and Conditions, submit this
Quotation in response to the RFQ.
This Quotation is offered by the Contractor this ___________ day of ___________________, 200_.
CONTRACTOR
I/We have the authority to bind the Contractor.
____________________________________________
(Legal Name of Contractor)
____________________________________________
(Signature of Authorized Signatory)
__________________________________________
(Signature of Authorized Signatory)
____________________________________________
(Print Name and Position of Authorized Signatory)
__________________________________________
(Print Name and Position of Authorized Signatory)
____________________________________________
(Signature of Authorized Signatory)
__________________________________________
(Signature of Authorized Signatory)
____________________________________________
(Print Name and Position of Authorized Signatory)
__________________________________________
(Print Name and Position of Authorized Signatory)
RFQ (Goods and Services) No.: 1220-41-25-09