14555 version 3 Page 1 of 3 Carry out defensive control of structure and vehicle fires Level 3 Credits 3 Purpose People credited with this unit standard are able to control structure and vehicle fires, and mop up structure and vehicle fires. Subfield Fire and Rescue Services Domain Fire and Rescue Services - Generic Fire Fighting Status Registered Status date 20 November 2009 Date version published 20 November 2009 Planned review date 31 December 2014 Entry information Prerequisite: Unit 3285, Demonstrate knowledge of protection of personal safety at vegetation fires; or Unit 3283, Demonstrate knowledge of personal safety at fire and emergency incidents; or demonstrate equivalent knowledge and skills. Accreditation Evaluation of documentation and visit by NZQA and industry. Standard setting body (SSB) Fire and Rescue Services Industry Training Organisation Accreditation and Moderation Action Plan (AMAP) reference 0039 This AMAP can be accessed at http://www.nzqa.govt.nz/framework/search/index.do. Special notes 1 Compliance with the fire and rescue service provider’s Health and Safety policy and procedures is mandatory. 2 Definition Fire and rescue service provider’s requirements refer to policies and procedures on safety and operation set down by each fire and rescue service employer or host organisation. 3 Assessment against this unit standard may take place under real or practical simulated conditions. New Zealand Qualifications Authority 2016 14555 version 3 Page 2 of 3 Elements and performance criteria Element 1 Control structure and vehicle fires. Performance criteria 1.1 Identification of hazards enables the safety of the operator and other personnel to be maintained and is in accordance with the fire and rescue service provider’s requirements. Range 1.2 Delivery system is set up in accordance with the fire and rescue service provider’s requirements. Range 1.3 may include but is not limited to – hose size, nozzle size, hydroblender, foam equipment, branch type, branch setting. Safety of the operator and other personnel is maintained for the duration of the operation and is in accordance with the fire and rescue service provider’s requirements. Range 1.4 hazardous materials, underfoot hazards, overhead hazards, materials burning, escape routes. selection of water pressure, use of backup personnel. Application of extinguishing agent meets the needs of the selected tactics and is in accordance with the fire and rescues service provider’s requirements. Range to cool, extinguish or control. 1.5 Fire is suppressed and the spread contained with minimal use of water or environmental damage in accordance with the fire and rescue service provider’s requirements. 1.6 Actions are taken to prevent hose damage in accordance with the fire and rescue service provider’s requirements. Range 1.7 kinks; damage from embers, tools and vehicles; water hammer. Communication with the pump operator is maintained for the duration of the operation in accordance with the fire and rescue service provider’s requirements. New Zealand Qualifications Authority 2016 14555 version 3 Page 3 of 3 Element 2 Mop up structure and vehicle fires. Performance criteria 2.1 Burning and smouldering material is identified and extinguished in accordance with the fire and rescue service provider’s requirements. 2.2 Safety of the operator and other personnel is maintained for the duration of mopping up operations in accordance with the fire and rescue service provider’s requirements. 2.3 Hose and other equipment are recommissioned in accordance with the fire and rescue service provider’s requirements. 2.4 Fire scene is secured in accordance with the fire and rescue service provider’s requirements. Please note Providers must be accredited by NZQA, or an inter-institutional body with delegated authority for quality assurance, before they can report credits from assessment against unit standards or deliver courses of study leading to that assessment. Industry Training Organisations must be accredited by NZQA before they can register credits from assessment against unit standards. Accredited providers and Industry Training Organisations assessing against unit standards must engage with the moderation system that applies to those standards. Accreditation requirements and an outline of the moderation system that applies to this standard are outlined in the Accreditation and Moderation Action Plan (AMAP). The AMAP also includes useful information about special requirements for organisations wishing to develop education and training programmes, such as minimum qualifications for tutors and assessors, and special resource requirements. Comments on this unit standard Please contact the Fire and Rescue Services Industry Training Organisation info@frsito.org.nz if you wish to suggest changes to the content of this unit standard. New Zealand Qualifications Authority 2016