Maryland Transportation Authority Police Training Facility Schematic Design Presentation December 13, 2007 Leah Clark Overview Location: Hawkins Point, Baltimore, Maryland Size: • 42,100 square feet • 2 stories above grade Project Team: • Owner: Maryland Transportation Authority • Mechanical and Electrical: Johnson, Mirmiran, & Thompson • Architectural: Rubeling & Associates • Civil and Structural: Carroll Engineering, Inc. • Construction Manager: To be determined by competitive bid among prequalified bidders Contractor: To be determined (by bid among prequalified contractors) First Floor Front Façade Physical Training Gym Classroom ‘A’ Firing Range Area Second Floor Sections Front Façade Classroom ‘A’ Physical Training Gymnasium Firing Range Area Sections Front Façade Classroom ‘A’ Physical Training Gymnasium Firing Range Area Classroom ‘A’ Design Criteria Light Distribution of Task Plane Uniformity on task plane Peripheral Emphasis Control and Flexibility Variety of tasks Multiple switching options Illuminance Levels (to perform task) Classroom ‘A’ Suspended Direct-Indirect Lighting Under-cabinet Lighting Whiteboard Lighting Whiteboard Zone 1 Zone 2 Zone 3 Projection Screen Zone 4 Zone 5 TV Classroom ‘A’ Range Area Design Criteria Control and Flexibility Pseudo-realistic training environments Multiple lighting systems Control system with preset lighting scenes Illuminance Levels Vertical face of the targets Interior Conditions – 50 fc Exterior Conditions – 10 fc Horizontal illuminance in the shooting lines Interior Conditions – 20 fc Exterior Conditions – 1 fc Direct Glare Lower cutoff angles for fixtures Range Area Dimmable Recessed Compact Fluorescent Lighting Red LED Lighting to signal when firing lane is in use High Pressure Sodium Fixtures to simulate exterior night lighting scene Range Area Dimmable Recessed Compact Fluorescent Lighting Red LED Lighting to signal when firing lane is in use Linear Fluorescent Lighting to simulate normal interior conditions Range Area Shooting Targets Floor Recessed Fixtures illuminate vertical face of targets Physical Training Gymnasium Design Criteria Control and Flexibility Allow fixtures to be Multiple lighting systems Control system Illuminance Levels Highlight Exposed Structure Uplight ceiling joists Physical Training Gymnasium Physical Training Gymnasium Front Facade Design Criteria Sense of Direction Higher light levels at entrance Points of interest Precast logos Light Pollution / Trespass Modeling of Faces and Objects Safety and security Security cameras Light Distribution on Surfaces Hierarchy of light Front Facade MdTA Police Logo Main Entrance MdTA Logo Standing Seam Metal Awning Building Identification Front Facade Thank You Questions & Comments