DATA SHEET CP64S COMMERCIAL PROCESSOR Optional SCP2S Equalizer-only Security Cover General Description The CP64S is a versatile commercial preamplifier designed for use in restaurants, bars, health clubs and offices. The CP64S is capable of serving two independent Zones. Two gated Paging inputs and four Program inputs are provided. Ports are provided for expansion of Page, Program or Zone signals. Four levels of priority are supported: • Priority Page • Non-Priority Page • Priority Program • Non-Priority Program The versatility of the CP64S allows a wide variety of system configurations while providing simple and intuitive controls. Two gated Paging Inputs capable of receiving mic or line level input are provided. Each features independent Mic/Line Pad, Gain Trim, detector Threshold, Zone Assign and Zone Level controls. Internally selectable phantom power is provided for each input. Each Paging input may be summed Pre- or PostZone Level control to allow setting Paging Level independent of Zone Level. An internal Paging Priority switch allows a “master” pager to override non-priority paging in its assigned zones, while allowing true dual zone independent paging. If no Paging Priority is selected, the Paging inputs mix together for applications like karaoke. Four stereo Program inputs are provided with independent Input Level controls. Any one of the four Program inputs may be independently assigned in each Zone. One of the Program inputs is a gated Priority Program input. When signal is detected at its input, it overrides any non-priority Program selection in the assigned Zones. The Priority detector features internal, adjustable Threshold and Release-Time controls. The CP64S has two Zone outputs: Zone 1 is stereo: Zone 2 is mono. Each Zone features independent: • Level • Program Select • Ducker On/Off • Ducker Depth • Servo-Locked-Limiter™ • 7 Band EQ (±12 dB) Versatile wired remote control interface ports are provided for Paging assignment, Zone Level and Zone Program source selection. Paging Zone and Source/Volume remote controls are available as accessories. Many options allow the installer to determine exactly which controls are employee accessible. The SCP2S is an optional security cover for the CP64S’s front panel EQ section. Any or all other front panel knobs can be removed and replaced with hole plugs — six are included with the SCP2S. Front panel Ducker Depth controls are screw driver adjust. The remote controls allow blank Decora™ plates to be remote control security covers. The remote knobs can also be individually replaced with hole plugs. Features • Two fully independent gated Mic/Line Paging Inputs • Paging Priority Assign • Page Ducking • Page / Program / Zone Expansion • Three stereo Program Inputs • One gated stereo Priority Program Input • • • • • • 7-Band graphic EQ for each Zone Servo-Locked-Limiter™ for each Zone Optional SCP2S Security Cover for EQ section only Optional PR2 Remote Page Assign Remote Optional ZR1 Remote Zone Level/Program Select Remote Universal Internal Power Supply (100-240 VAC) Data Sheet-1 CP64S COMMERCIAL PROCESSOR Features and Specifications Parameter MIC/LINE PAGING INPUTS ..........Input Type ..........RFI Filter ..........Gain range ..........Frequency Response ..........Input Referred Noise ..........CMR ..........THD+N ..........Phantom Power ..........Mic Input impedance ..........Line Pad ..........Line Input impedance ..........Signal Detector Range ..........Signal Detector Attack ..........Signal Detector Release ..........Overload Indicator ..........Front Panel Zone Assign ..........Remote Zone Assign ..........Pre/Post Paging assign ..........Page Priority Assign ..........Paging Zone Level Adjust ..........Page Remote Selector PROGRAM INPUTS ..........Input Type ..........Input Level adjust ..........Frequency Response ..........Input impedance .....Priority Program Input ...............Input Detector Range ...............Release Time Range ...............Attack Time ...............Assign EXPAND OUTPUTS ..........Number of Expand Outputs ..........Expand Selector ..........Output Type ..........Gain: Zone ....................Page/Program ..........Frequency Response Data Sheet-2 Specification Two mono Euroblock Yes +30 to +60 30 Hz to 40 kHz -125 40 .05 +15 500 30 14.5k off to +4 .5 3 +16 Remote, Z1, Z2, Both Off, Z1, Z2, Both Limit Units Conditions/Comments All controls duplicated for both inputs Balanced; Instrumentation amplifier 2 +0/-3 1 min .01 4% 1% 1 1% typ typ typ 1 dB dB dBu dB % VDC Ω dB Ω dBu msec sec dBu Continuously adjustable Maximum gain Gain: 60 dB, Rs: 150 Ω, BW: 20 kHz 20 to 20 kHz Gain: 30 dB, +4 dBu out, 1 kHz, BW: 80 kHz Internal switch Each leg to ground off to -35 5 to 20 50 OFF, Z1, Z2 or Both typ typ typ dBu sec msec Internal trim, factory set to -50 dBu Internal trim, factory set to 12 seconds For a 20 dB step; Fixed. Each leg to ground. Defeats phantom power Continuously adjustable Fixed Fixed 4 dB before clipping. Z1 = Zone 1; Z2 = Zone 2 Internal pull-up; Active low; Switch closure to ground or 5 volt TTL logic. Summed with program Pre VCA or Post VCA via Internal switch P1 (Page 1) 1 dBu Priority pager overrides non-priority pager only NO (none) in assigned zones; Selecting NONE allows the P2 (Page 2) two pagers to mix. off to 0 dB Independent for each Zone 11 = Off 1 dBu Internal pull-up. Active low; 10 = Z1 (Zone 1) Switch closure to Ground or 5 volt TTL logic. 01 = Z2 (Zone 2) 00 = Both Four stereo All controls duplicated for all four inputs RCA Unbalanced off to 0 dB 10 Hz to 50 kHz +0/-3 dB 10 k 20% Ω Two Zone Program only Page only Balanced 12 6 10 Hz to 50 kHz All controls duplicated for both zones Z1 & Z2, both mono Note: If a Page signal is summed Post-VCA, it is not present on the Expand Zone output. It is available for the Expand Page output. Cross-coupled; Euroblock connector 1 1 +0/-3 dB dB dB continued... CP64S COMMERCIAL PROCESSOR Parameter ..........S/N ..........THD+N ..........Crosstalk ..........Output impedance ..........Maximum Output ZONE OUTPUTS ..........Number of Outputs ..........Output Type ..........Gain: From Program Inputs ....................From Page Inputs ..........Frequency Response ..........S/N ..........THD+N ..........Crosstalk ..........Output impedance ..........Maximum Output ..........Signal Present Indicator ..........Overload Indicator ..........Ducker: Enable ...............Depth Range ..........Limiter: Threshold Range ...............Attack Time ...............Release Time ...............Ratio PROGRAM SELECTION ..........Local (Front Panel) ..........Zone RMT Selector ..........Zone RMT Volume (RMT engaged) ..........Off Isolation EQ CIRCUITS ..........Boost/Cut Range ..........ISO Center Frequencies ..........Filter Bandwidth UNIT: Conformity ..........Universal Line Voltage ..........Construction ..........Size ..........Weight Shipping: Size ..........Weight Specification -84 .05 -75 100 +24 dBu Two Euroblock 12 6 10 Hz to 50 kHz -84 .05 -75 100 +20 -20 +16 ON/OFF -50 to -6 -20 to +20 20 250 15:1 Limit 1 .01 max 1% typ Units dBr % dB Ω Zone 1 Stereo, Zone 2 mono Balanced; Cross-coupled 1 1 +0/-3 1 .01 max 1% typ typ typ dB dB dB dBr % dB Ω dBu dBu dBu typ typ typ typ typ dB dB msec msec L1, L2, L3 or P (priority) 11 = L1 10 = L2 00 = L3 01 = P Attenuation = 64 mV/dB Range 0 V to +5 V (0 dB to -78 dB) -80 typ dB +12 to -12 40, 100, 250, 630, 1.6k, 4k, 10k 2 CE, FCC, CULUS 100-240 VAC, 50/60 Hz All Steel 1.75"H x 19"W x 8.5"D 5 lb 4.5" x 20.3" x 13.75" 9 lb Conditions/Comments re +4 dBu. BW: 20 Hz-20 kHz +4 dBu, 1 kHz, BW: 80 kHz 1 kHz, Rs: 25 Ω, ch/ch Each leg Ri: 2 kΩ .5 3% dB Hz 3% oct re +4 dBu. BW: 20 Hz-20 kHz +4 dBu, 1 kHz, BW: 80 kHz 1 kHz, Rs: 25 Ω, (L/R or ch/ch) Each leg Ri = 600 Ω Maximum 4 dB before clipping Independently defeatable for each Zone Continuously adjustable Continuously adjustable For a 10 dB step; Fixed. For a 10 dB step; Fixed. Soft knee. Independent for each Zone Internal pull-up. Active low. Switch closure to ground or 5 volt TTL. Gray Code logic. Control element: 2 kΩ pot, reverse-log taper; Or any ground referenced 0-5 VDC control. 1 kHz, Rs: 25 Ω Zone 1: Stereo 7-band. Zone 2: Mono 7-band. 12 watts 1U (4.4 cm x 48.3 cm x 21.6 cm) (2.3 kg) (11.5 cm x 52 cm x 35 cm) (4.1 kg) Note: 0 dBu = 0.775 Vrms Data Sheet-3 CP64S COMMERCIAL PROCESSOR Block Diagram DEPTH -50dB LEFT LINE 1 0 dB RIGHT -6dB PROGRAM ZONE 2 INPUT SELECTOR + PAGE DUCKER 6 dB + SIG ON/OFF P R O G R A M I N P U T S + ZONE 6 dB PAGE OL ZONE 2 EXPAND - -20dB Z2 LIMIT THRESHOLD +20dB + Z2 PAGE LEFT LINE 2 0 dB Z2 VC LEFT Z2 POST PAGE DEPTH -6dB -50dB LINE 3 0 dB RIGHT SIG + LEFT DEPTH PROGRAM + OL PRIORITY + ZONE 6 dB PAGE 0 dB + PAGE DUCKER 6 dB + -20dB - Z1 LIMIT THRESHOLD +20dB ZONE 1 EXPAND + Z1 POST PAGE - + Z1 PAGE 6 dB ON/OFF PRGM PRIORITY RELEASE * TIME 12 24 SEC. -60dBu -35dBu Z1 A Z2 B COM P1 (ACTIVE LOW) P2 A B Z1 REMOTE GRAY CODE 11 10 01 00 P1 P1 A B CH 1 CH 2 CH 3 CH 4 Z2 PROGRAM SELECT (ACTIVE LOW) PAGER NONE ASSIGN LOGIC COM PAGE ASSIGN P2 PAGE PRIORITY * A B COM A B COM Z1 LOCAL (FRONT PANEL) Z2 P2 A B CHANNEL SELECT AUTO FADE LOGIC + COM RMT SEL A B COM ZONE 1 RMT/LOCAL P + A G PAGE -1 E I N P + U PAGE 2 T S PAGE OL A B ZONE 1 LEVEL 15V PHTM PWR PAGE 1 DETECT SENS. - P2 ACTIVE 30dB PAD TRIM Z1 PAGE Z1 PAGE LEVEL + PAGE 2 DETECT SENS. - 15V PHTM PWR +4dB TRIM 30 TO 60dB PRE/POST VCA Z2 PAGE LEVEL DET * Z1 POST PAGE Z2 PRE PAGE * MIC/ LINE 30dB PAD LOCAL (FRONT PANEL) Z1 PRE PAGE P1 30 TO 60dB RMT RMT OR DET * MIC/ LINE +4dB + P2 PAGE BRIDGE PRE/POST VCA * Z2 POST PAGE Z2 PAGE * INTERNAL CONTROLS Data Sheet-4 +5 COM P1 ACTIVE - + COM LOCAL ZONE ASSIGN (FRONT PANEL) RMT Z1 Z2 BOTH OFF Z1 Z2 BOTH COM REMOTE ZONE ASSIGN 11 10 01 00 PRIORITY ASSIGN PAGE DUCKER A B 7-BAND EQ Z1 PRE PAGE ZONE 1 RIGHT Z1 VC PRGM PRIORITY THRESHOLD * OFF Z1 Z2 BOTH ZONE 1 LEFT 6 dB Z1 VC + MONO * + + 7-BAND EQ PAGE DUCKER 6 dB ZONE 1 INPUT SELECTOR RIGHT - + 7-BAND EQ Z2 PRE PAGE RIGHT 11 10 01 00 ZONE 2 6 dB ZONE 2 RMT/LOCAL +5 ZONE 2 LEVEL RMT LOCAL (FRONT PANEL) RMT Z1 VC + Z2 VC CP64S COMMERCIAL PROCESSOR Remote Controls L2 L3 L1 Two optional wired remote control units are available. The PR2 allows remote control of Page 1 and Page 2 Zone Assign selection. The ZR1 allows remote control of Zone Level and Zone Program selection. One PR2 and two ZR1 remotes may be used with each CP64S. The PR2 and ZR1 may be installed in standard electrical boxes (minimum depth 2.25"). The remotes connect to the CP64S through Euroblock connectors. The PR2 is a 5-wire remote with 2 bits to select Page 1 Assign, one wire for shield/gnd and 2 bits for Page 2 Assign. Selector logic is active low BCD with pull-up provided in the CP64S. Control may be a simple switch closure to ground or 5 volt TTL. Page 1 and Page 2 bits may be paralleled so that one switch controls both Page Assigns. Remote control is initiated by setting the front panel Paging Zone Assign selector to RMT. The ZR1 is a 5-wire remote with 2 bits for Zone Program selection (active low Gray Code), a common shield/ground and two wires for ratiometric DC control of Zone Level. Zone 1 and Zone 2 ZR1 remote ports may be paralleled so that a single remote controls both Zones. Selector logic is active low Gray Code with pull-up provided in the CP64S. Control may be a simple switch closure to ground or 5 volt TTL. Remote control for each zone is initiated by engaging the RMT switch (located on the front panel) for that Zone. For installations that require a volume remote but don't need the program selection of the ZR1, Rane makes the model VR1 Volume Remote. P PROGRAM SELECT 4 ZR1 6 2 8 0 10 LEVEL OFF Z1 Z2 BOTH PAGE 1 ASSIGN PR2 OFF Z1 Z2 BOTH PAGE 2 ASSIGN Example System: Retail Store CP64S COMMERCIAL AUDIO EQUIPMENT 24TJ Z2 PGM Z2 LEVEL OUTPUTS Z2 EXPAND Z2 MONO REMOTES WIRING 100-240 V 50/60 Hz 12 WATTS R ZONE 2 EXPAND OUT Z1 PGM RANE CORPORATION D1 D0 +8 ZONE 1 EXPAND OUT –20 ZONE PAGE ZONE PAGE Z1 LEVEL 2 1 PGM PGM Vr Vc ZONE 2 PROGRAM INPUTS LIMITER ZONE 1 ZONE 2 ALL AUDIO AND REMOTES ARE CLASS 2 WIRING MIN MAX Vr Vc Z1 EXPAND Z1 RIGHT + – + – ZONE 1 +8 +20 –20 PRIORITY ASSIGN ZONE off 1 +20 L Z2 Z1R Z1L EX1 EX2 1&2 R R 3 2 1 1 2 3 Limit Fault 6 Comp Load Exp Ready 3 3 Limit Fault 6 Comp Load Exp Ready 12 24 Limit Fault 6 Comp Load Exp Ready dB Headroom Z2 Z1 DVR INPUT 2 + – +30 +60 MIC LINE IN2 OL +30 MIC +60 LINE PRIORITY 1 TELEPHONE PAGE OUT 62 1:58 ON 3 Limit Fault 6 Comp Load Exp Ready 12 PAGE 1 TRIM TELEPHONE HOLD MUSIC 4 3 12 24 dB Headroom REMOTE 2 MUSIC SERVICE MULTICHANNEL AMPLIFIER 24 PAGE 2 PAGE 1 DETECT THRESHOLD IN1 PRE-RECORDED ADVERTISEMENT OR BREAK BELL 12 PAGING INPUTS PAGE 2 TRIM PRIORITY 2 CD PLAYER dB Headroom INPUT 1 Z1 Z2 2 PRIORITY Z1 LEFT + – REMOTE 1 REMOTE PAGE ZONE ASSIGN WIRING L MA 4 DIGITAL AMPLIFIER 24 dB Headroom DISTRIBUTED OUTPUTS REQUIRE TRANSFORMERS ZR1 ZR1 DISTRIBUTED L1 L2 L3 P PROGRAM SELECT 4 6 2 8 0 PROGRAM SELECT STEREO L1 ZONE 2 LEVEL L2 L3 P PROGRAM SELECT 4 6 0 10 2 10 LEVEL 8 PROGRAM SELECT ZONE 1 DISTRIBUTED EXPAND 1 LEVEL LEVEL RETAIL / SHOP FLOOR MEETING / DEMO ROOM OFFICE PAGE Data Sheet-5 CP64S COMMERCIAL PROCESSOR Example System: Auto Dealer and Service CP64S Z2 PGM COMMERCIAL AUDIO EQUIPMENT 24TJ OUTPUTS REMOTES Z2 LEVEL WIRING 100-240 V 50/60 Hz 12 WATTS R ZONE 2 EXPAND OUT Z1 PGM RANE CORPORATION D1 D0 LIMITER ZONE 1 ZONE 2 +8 ZONE 1 EXPAND OUT –20 ZONE PAGE ZONE PAGE Z1 LEVEL 2 1 PGM PGM Vr Vc ZONE 2 PROGRAM INPUTS Z2 EXPAND Z2 MONO ALL AUDIO AND REMOTES ARE CLASS 2 WIRING MIN MAX Vr Vc Z1 EXPAND Z1 RIGHT + – + – ZONE 1 +8 +20 –20 PRIORITY ASSIGN ZONE off 1 +20 L INPUT 1 PAGING INPUTS PAGE 1 TRIM PAGE 2 TRIM Z1 Z2 2 1&2 R PRIORITY Z1 LEFT + – REMOTE 1 REMOTE PAGE ZONE ASSIGN WIRING L R 3 2 1 PAGE 2 PAGE 1 DETECT THRESHOLD Z2 Z1 Z2 Z1R Z1L EX1 EX2 PRIORITY 4 PRIORITY 3 REMOTE 2 +30 +60 MIC LINE OL +30 MIC +60 LINE IN2 IN1 TO SET PAGE PRIORITY 2 PRIORITY 1 PRIORITY SUM PAGE 1 & PAGE 2 POST VCA PRIORITY 2 SUM PAGE 2 POST VCA MUSIC SERVICE MULTICHANNEL AMPLIFIER INPUT 2 + – 10 8:58 1 2 0 0 3 3 3 6 6 12 CD 3 0 POWER EXPAND 2 MUSIC ON HOLD MA 3 MULTICHANNEL AMPLIFIER 6 12 12 dB CHANNEL OUTPUT HEADROOM PR2 POWER TELEPHONE KEY SERVICE UNIT OFF Z1 Z2 BOTH PAGE 1 ASSIGN ZR1 ZR1 OFF Z1 Z2 BOTH PAGE 2 ASSIGN L1 L2 L3 DISTRIBUTED (USE TRANSFORMERS) P PROGRAM SELECT 4 6 0 10 2 ZONE 2 8 L2 L3 L1 MASTER PAGE LEFT RIGHT P PROGRAM SELECT 4 6 0 10 2 ZONE 1 8 LEVEL RECEPTION 12:00 LEVEL PROMO DVD SALES & CREDIT OFFICES SALES FLOOR EXPAND 1 EMERGENCY PAGE SET PAGE PRIORITY TO P2 IN2 PRIORITY 1 CP64S Z2 PGM COMMERCIAL AUDIO EQUIPMENT 24TJ Z2 LEVEL REMOTES OUTPUTS WIRING 100-240 V 50/60 Hz 12 WATTS MIN MAX Vr Vc R ZONE 2 EXPAND OUT Z1 PGM RANE CORPORATION D1 D0 LIMITER ZONE 1 ZONE 2 +8 ZONE 1 EXPAND OUT –20 ZONE PAGE ZONE PAGE Z1 LEVEL 2 1 PGM PGM Vr Vc ZONE 2 PROGRAM INPUTS Z2 EXPAND Z2 MONO ALL AUDIO AND REMOTES ARE CLASS 2 WIRING Z1 EXPAND Z1 RIGHT + – + – ZONE 1 Z2 Z1 LEFT + – Z1L EX2 +8 +20 –20 PRIORITY ASSIGN ZONE off 1 +20 L REMOTE 1 REMOTE PAGE ZONE ASSIGN WIRING L 1&2 R PRIORITY R 3 2 1 PAGE 2 PAGE 1 DETECT THRESHOLD REMOTE 2 Z2 Z1 0 3 3 6 6 POWER MA 3 10 8:58 MULTICHANNEL AMPLIFIER 12 dB CHANNEL OUTPUT HEADROOM SERVICE RECEPTION ZR1 ZR1 L1 L2 L3 P 4 6 0 10 2 8 LEVEL Data Sheet-6 DISTRIBUTED ZONE 2 L1 L2 L3 P PROGRAM SELECT 4 6 0 10 2 SERVICE WRITER AND PARTS ROOM DISTRIBUTED DISTRIBUTED ZONE 1 EXPAND 2 8 LEVEL SERVICE BAYS RESTROOMS OL +30 PRIORITY 2 MIC OR TELEPHONE PAGE TO SERVICE BOTH PAGE 1 ASSIGN HOLE PLUG POWER DISTRIBUTED OUTPUTS REQUIRE TRANSFORMERS PROGRAM SELECT +60 LINE CD 6 12 Z1 Z2 +30 MIC 3 0 3 12 INPUT 2 + – IN1 PRIORITY 3 OFF 2 0 PAGE 1 TRIM PAGE 2 TRIM Z1 Z2 OPTIONAL SOURCES PRIORITY 4 1 PAGING INPUTS 2 PR2 MULTICHANNEL AMPLIFIER INPUT 1 MIC +60 LINE CP64S COMMERCIAL PROCESSOR Example System: Karaoke Diner CP64S Z2 PGM COMMERCIAL AUDIO EQUIPMENT 24TJ Z2 LEVEL OUTPUTS Z2 EXPAND Z2 MONO REMOTES WIRING 100-240 V 50/60 Hz 12 WATTS R ZONE 2 EXPAND OUT D1 D0 ZONE 2 +8 ZONE 1 EXPAND OUT –20 ZONE PAGE ZONE PAGE Z1 LEVEL 2 1 PGM PGM Vr Vc Z1 PGM RANE CORPORATION PROGRAM INPUTS LIMITER ZONE 1 ZONE 2 ALL AUDIO AND REMOTES ARE CLASS 2 WIRING MIN MAX Vr Vc Z1 EXPAND Z1 RIGHT + – + – ZONE 1 Z2 EX2 +8 +20 –20 PRIORITY ASSIGN ZONE off 1 +20 R PRIORITY Z1L REMOTE 1 REMOTE PAGE ZONE ASSIGN WIRING L 1 2 3 R 3 2 1 3 Limit Fault 3 Limit Fault 3 Limit Fault Load 6 Comp Load 6 Comp Load 6 Comp Load Exp Ready Exp Ready Exp Ready Exp Ready 12 24 dB Headroom 12 12 24 12 24 dB Headroom Z2 Z1 L2 L3 PROGRAM SELECT P OFF Z1 Z2 INPUT 2 + – +30 +60 MIC LINE OL +30 MIC +60 LINE PAGE IN LOUNGE OR DINING AREA BOTH PAGE 1 ASSIGN MA 4 DIGITAL AMPLIFIER 24 dB Headroom REMOTE 2 IN2 IN1 PROGRAM SELECT ON Fault Comp PAGE 2 PAGE 1 DETECT THRESHOLD PR2 L1 4 Limit 6 PAGE 1 TRIM PAGE 2 TRIM PRIORITY 1 MULTICHANNEL AMPLIFIER PAGING INPUTS Z1 Z2 ZR1 3 INPUT 1 2 1&2 Z1 LEFT + – Z1R L dB Headroom 4 6 0 10 2 LEVEL 8 OFF STREAMING MUSIC SERVICE LEVEL Z1 Z2 BOTH PAGE 2 ASSIGN SINGER 1 1-1-05 ZR1 KARAOKE DVD SINGER 2 or ANNOUNCER or DINING PAGE CH 68 L1 L2 L3 P PROGRAM SELECT 4 6 0 10 2 8 PROGRAM SELECT ZONE 2 LEVEL DVR ZONE 1 LEVEL 62 1:58 OTHER PROGRAM SOURCE KARAOKE LOUNGE DINING AREA Example System: Restaurant CP64S Z2 PGM COMMERCIAL AUDIO EQUIPMENT 24TJ Z2 LEVEL OUTPUTS Z2 EXPAND Z2 MONO REMOTES WIRING 100-240 V 50/60 Hz 12 WATTS MIN MAX Vr Vc R ZONE 2 EXPAND OUT Z1 PGM RANE CORPORATION D1 D0 ZONE 1 PROGRAM INPUTS LIMITER ZONE 1 ZONE 2 ALL AUDIO AND REMOTES ARE CLASS 2 WIRING +8 ZONE 1 EXPAND OUT –20 ZONE PAGE ZONE PAGE Z1 LEVEL 2 1 PGM PGM Vr Vc Z1 EXPAND Z1 RIGHT + – + – ZONE 2 +8 +20 –20 PRIORITY ASSIGN ZONE off 1 +20 L Z2 Z1R Z1L EX1 EX2 L R 1&2 1 2 3 Limit Fault 6 Comp Load Exp Ready 12 24 dB Headroom 3 3 Limit Fault 6 Comp Load Exp Ready 12 24 3 Limit Fault 6 Comp Load Exp Ready 12 24 dB Headroom dB Headroom 1 4 3 PAGE 2 TRIM PAGE 1 TRIM PRIORITY 3 2 1 PAGE 2 PAGE 1 DETECT THRESHOLD Z2 Z1 INPUT 2 + – IN1 PRIORITY 4 +30 +60 MIC LINE OL +30 MIC +60 LINE IN2 PRIORITY 2 PRIORITY 1 MUSIC SERVICE 4 REMOTE 2 PR2 PAGE 1 ON 3 Limit Fault 6 Comp Load Exp Ready 12 2 PAGING INPUTS Z1 Z2 R 3 TO TELEPHONE MUSIC-ON-HOLD MULTICHANNEL AMPLIFIER INPUT 1 2 PRIORITY Z1 LEFT + – REMOTE 1 REMOTE PAGE ZONE ASSIGN WIRING MA 4 CH 68 DIGITAL AMPLIFIER 24 OFF Z1 Z2 BOTH dB Headroom DVR PAGE 1 ASSIGN OFF 10 8:58 70V TRANSFORMERS Z1 Z2 BOTH PAGE 2 ASSIGN PAGE ASSIGN HOLE PLUG BLU-RAY MT 4 MULTICHANNEL TRANSFORMER RECEPTION STATION PR2 ZONE 2 ZONE 2 EXPAND ZONE 1 EXPAND ZONE 1 OFF PAGE 2 Z1 Z2 BOTH PAGE 1 ASSIGN OFF ZR1 DISTRIBUTED ZR1 L1 L2 L3 P PROGRAM SELECT 4 6 2 8 0 DISTRIBUTED DISTRIBUTED PROGRAM SELECT PATIO DINING L1 L2 L3 LEVEL 6 2 10 8 0 LEVEL Z1 Z2 BOTH PAGE 2 ASSIGN OFFICE PAGE RESTROOMS P PROGRAM SELECT 4 DISTRIBUTED HOLE PLUG 10 PROGRAM SELECT LEVEL MIC OR TELEPHONE PAGE TELEPHONE KEY SERVICE 10 8 19:58 JUKEBOX LEVEL DINING ROOM LOUNGE OFFICES Data Sheet-7 CP64S COMMERCIAL PROCESSOR Rear Panel Architectural Specifications The processor shall provide two fully independent gated paging inputs, three line-level non-priority program inputs and one gated line-level priority program input. Two zone outputs shall be served. Zone 1 shall be a stereo zone with balanced, crosscoupled outputs. Zone 2 shall be a mono zone with a balanced cross-coupled output. Mono expansion ports for page, program or zone signals shall be provided for each zone. Wired remote control ports shall be provided for paging zone assign, zone program select and zone level. Page inputs shall use a 5-pin Euroblock connector. Paging controls shall include: • 30 dB mic/line input pad. • Input gain trim range of 30 dB to 60 dB. • Mic gate threshold (range -∞ to +4 dBu). • 15 volt phantom power (internal switch). • Paging priority (page 1, none, page 2; internal switch). • Pre- or post-zone level summing (internal switch). • Front panel paging zone assign (Remote, Z1, Z2, Both). • Remote paging zone assign (Off, Z1, Z2, Both). • Paging zone level. Each Program input shall have stereo RCA input jacks and independent input level control. The priority program assign switch shall provide priority program override to zone 1, zone 2, both, or neither (off). The gated priority program input shall have internally adjustable threshold and release time controls. Zone outputs shall use 3-pin Euroblock connectors. Zone controls shall include: • Ducker on/off • Ducker depth (-6 to -50 dB) • Program select (L1, L2, L3, P) • Zone level • 7-band graphic equalizer (±12 dB) • Servo-Locked-Limiter™ threshold (-20 to +20 dBu) • Mono switch for Zone 1 (internal) • Remote engage switch Wired remote ports shall use 3-pin Euroblock connectors. Remote logic shall be active low with internal pull-up. Remote level control shall be ratiometric DC control with 5 volt reference. The unit shall be capable of operation by means of its own built-in universal power supply operating at 100-240 VAC and meet CE requirements. The unit shall be UL and cUL listed. The unit shall be entirely constructed from cold-rolled steel. Reliability and efficiency are to be primary design considerations. The unit shall be a Rane Corporation CP64S Commercial Processor. Available Accessories • • • • • SCP2S Security Cover (for EQ section) PR2 Page Assign Remote Control ZR1 Zone Source/Volume Remote Control VR1 Volume Remote Control Hole Plugs (6 Provided with SCP2S) ©Rane Corporation 10802 47th Ave. W., Mukilteo WA 98275-5000 USA TEL 425-355-6000 FAX 425-347-7757 WEB rane.com Data Sheet-8 All features & specifications subject to change without notice. 9-2015