Prisma FiberLinX-II Gigabit Media Converter Module Installation Instructions Overview Introduction The Prisma® FiberLinX-II Gigabit Media Converter module connects two remote networks over fiber optics. This module allows administrators to observe both the end-points and the fiber link between them as a single management entity and not as separate networks. No host management traffic is visible to the remote or customer network. Access to the customer network is not required, allowing end-to-end data integrity. Purpose This document provides product information and instructions for installing the module. Overview Qualified Personnel Only appropriately qualified and skilled service personnel should attempt to install, operate, maintain, and service this product. WARNING: Allow only qualified and skilled personnel to install, operate, maintain, and service this product. Otherwise, personal injury or equipment damage may occur. In This Document 2 Important Safety Instructions ...................................................................................3 Module Description....................................................................................................9 PrismaView and iConfig..........................................................................................11 Hardware Configuration ......................................................................................... 14 Installation Instructions ...........................................................................................16 Software Configuration ...........................................................................................17 Using Telnet............................................................................................................... 21 Application Overview..............................................................................................39 Application Examples ..............................................................................................40 Troubleshooting........................................................................................................53 Serial Port Pinout ...................................................................................................... 60 Fiber Optic Cleaning Guidelines ............................................................................61 For Information .........................................................................................................63 4022582 Rev B Important Safety Instructions Important Safety Instructions Read and Retain Instructions Carefully read all safety and operating instructions before operating this equipment, and retain them for future reference. Follow Instructions and Heed Warnings Follow all operating and use instructions. Pay attention to all warnings and cautions in the operating instructions, as well as those that are affixed to this equipment. Terminology The terms defined below are used in this document. The definitions given are based on those found in safety standards. Service Personnel - The term service personnel applies to trained and qualified individuals who are allowed to install, replace, or service electrical equipment. The service personnel are expected to use their experience and technical skills to avoid possible injury to themselves and others due to hazards that exist in service and restricted access areas. User and Operator - The terms user and operator apply to persons other than service personnel. Ground(ing) and Earth(ing) - The terms ground(ing) and earth(ing) are synonymous. This document uses ground(ing) for clarity, but it can be interpreted as having the same meaning as earth(ing). Electrostatic Discharge Electrostatic discharge (ESD) results from the static electricity buildup on the human body and other objects. This static discharge can degrade components and cause failures. Take the following precautions against electrostatic discharge: Use an anti-static bench mat and a wrist strap or ankle strap designed to safely ground ESD potentials through a resistive element. Keep components in their anti-static packaging until installed. Avoid touching electronic components when installing a module. 4022582 Rev B 3 Important Safety Instructions Modifications This equipment has been designed and tested to comply with applicable safety, laser safety, and EMC regulations, codes, and standards to ensure safe operation in its intended environment. Refer to this equipment's data sheet for details about regulatory compliance approvals. Do not make modifications to this equipment. Any changes or modifications could void the user’s authority to operate this equipment. Modifications have the potential to degrade the level of protection built into this equipment, putting people and property at risk of injury or damage. Those persons making any modifications expose themselves to the penalties arising from proven non-compliance with regulatory requirements and to civil litigation for compensation in respect of consequential damages or injury. EMC Compliance Statements FCC Statement for Class A Equipment This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when this equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case users will be required to correct the interference at their own expense. FCC Statement for Class B Equipment This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the 4 4022582 Rev B Important Safety Instructions receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Industry Canada - Industrie Canadienne Statement This apparatus complies with Canadian ICES-003. Cet appareil est confome à la norme NMB-003 du Canada. CENELEC/CISPR Statement with Respect to Class A Information Technology Equipment This is a Class A equipment. In a domestic environment this equipment may cause radio interference in which case the user may be required to take adequate measures. 4022582 Rev B 5 Laser Safety Laser Safety Introduction This equipment contains an infrared laser that transmits intensity-modulated light and emits invisible radiation. Warning: Radiation WARNING: Avoid personal injury! Use of controls, adjustments, or procedures other than those specified herein may result in hazardous radiation exposure. Avoid personal injury! The laser light source on this equipment (if a transmitter) or the fiber cables connected to this equipment emit invisible laser radiation. Avoid direct exposure to the laser light source. Avoid personal injury! Viewing the laser output (if a transmitter) or fiber cable with optical instruments (such as eye loupes, magnifiers, or microscopes) may pose an eye hazard. Do not apply power to this equipment if the fiber is unmated or unterminated. Do not stare into an unmated fiber or at any mirror-like surface that could reflect light emitted from an unterminated fiber. Do not view an activated fiber with optical instruments (e.g., eye loupes, magnifiers, microscopes). Use safety-approved optical fiber cable to maintain compliance with applicable laser safety requirements. Warning: Fiber Optic Cables WARNING: Avoid personal injury! Qualified service personnel may only perform the procedures in this manual. Wear safety glasses and use extreme caution when handling fiber optic cables, particularly during splicing or terminating operations. The thin glass fiber core at the center of the cable is fragile when exposed by the removal of cladding and buffer material. It easily fragments into glass splinters. Using tweezers, place splinters immediately in a sealed waste container and dispose of them safely in accordance with local regulations. 6 4022582 Rev B Laser Safety Safe Operation for Software Controlling Optical Transmission Equipment If this manual discusses software, the software described is used to monitor and/or control ours and other vendors’ electrical and optical equipment designed to transmit video, voice, or data signals. Certain safety precautions must be observed when operating equipment of this nature. For equipment specific safety requirements, refer to the appropriate section of the equipment documentation. For safe operation of this software, refer to the following warnings. WARNING: Ensure that all optical connections are complete or terminated before using this equipment to remotely control a laser device. An optical or laser device can pose a hazard to remotely located personnel when operated without their knowledge. Allow only personnel trained in laser safety to operate this software. Otherwise, injuries to personnel may occur. Restrict access of this software to authorized personnel only. Install this software in equipment that is located in a restricted access area. Laser Safety Information This laser based multi-mode transceiver is an IEC 60825-1 Amend. 2 Class 1 laser product. It complies with FDA performance standards (21 CFR 1040.10 and 1040.11) for laser products except for deviations pursuant to Laser Notice No. 50, dated July 26, 2001. Note: All adjustments have been made at the factory prior to shipment of the module. No maintenance or alteration of this device is required. No adjustments or controls provided. Class 1 Laser Product Avoid possible exposure to hazardous levels of invisible laser radiation; do not view laser aperture. Warning Label The following label applies to this module, but cannot be affixed due to space limitations. Class 1 Laser product, Luokan 1 Laserlaite, Laser Klasse 1, Appareil A'Laser de Classe 1 4022582 Rev B 7 Laser Safety Product Laser Information The following illustration displays the location of laser aperture on the module front panel. 8 4022582 Rev B Module Description Module Description Overview The Prisma FiberLinX-II Gigabit module allows network operators to deploy managed Ethernet services with a full range of remote management, traffic monitoring, and alarm reporting features. This unit converts 1000 Mbps fiber to 10/100/1000 Mbps copper. Several fiber connectors are available (SC or SFP), and the module is supplied in a variety of wavelengths supporting higher density CWDM and single-strand fiber operation. The module supports two main configuration modes: Standalone or Host/Remote. When using Host/Remote, the Remote modules can be fully managed without an IP address using a secure management channel when the SNMP module is installed in the same chassis. In either mode, the network operator can choose to assign an IP address to the Host or Standalone module. If using a local Prisma MediaCenter™ managed chassis, however, all local and remotely connected Prisma FiberLinX-II Gigabit modules can be managed using the single IP address of the chassis. This not only preserves IP addresses and reduces configuration complexity, but also keeps management traffic traveling on the non-IP based transmission channel isolated from customer traffic, thereby enhancing network security. Module Features The Prisma FiberLinX-II Gigabit module offers the following features: Secure separation of SNMP management network from the data network IEEE 802.1Q VLAN Tagging Q-in-Q VLAN Extra-Tagging Remote traffic monitoring Remote automatic alarms Bandwidth limiting FiberAlert (loss return) FX and TX LinkLoss (loss pass-through) Loopback testing Auto-negotiation Selective advertising 4022582 Rev B 9 Module Description AutoCross Compatible Chassis The Prisma FiberLinX-II Gigabit is a double-slot chassis-mounted module. Compatible chassis include the following: Prisma MediaCenter 3-Slot Chassis Prisma MediaCenter 6-Slot Chassis Prisma MediaCenter 8-Slot Chassis Prisma MediaCenter 20-Slot Chassis Port Interfaces Every Prisma FiberLinX-II Gigabit module includes the following port: One 10/100/1000 twisted-pair port (EXT MGMT) for management Each module also includes one of the following uplink ports: One fixed 1000 Mbps fiber port A SFP port capable of receiving a gigabit fiber optic SFP module or a gigabit twisted-pair (RJ-45) SFP module Each module further includes one of the following DATA ports: A 10/100/1000 twisted-pair (RJ-45) port A SFP port capable of receiving a gigabit fiber optic SFP module or a gigabit twisted-pair (RJ-45) SFP module In addition, a DB-9 port is available for management through a serial port connection. Refer to Serial Port Pinout (on page 60) for more information. You can easily configure the module using either the serial craft port connection, a SNMP management application such as PrismaView™, or a Telnet session. CAUTION: Use shielded cable with the Prisma FiberLinX-II Gigabit to maintain EMI/RFI compliance. Craft Serial Port Connection The RS-232 serial connection through the DB-9 connector on the module provides access to the Prisma FiberLinX-II Gigabit module configuration screens. These configuration screens are also accessible from a Telnet connection. 10 4022582 Rev B PrismaView and iConfig PrismaView and iConfig PrismaView Management Application Software PrismaView management application software is a network management application for intelligent networking devices. It features a graphical user interface (GUI), and gives network managers the ability to monitor and control the modules. The application is available in several versions, and can also function as a snap-in module for Hewlett Packard’s (HP) OpenView Network Node Manager (NNM). Note: Select the right version of PrismaView software for your operating system. Refer to the Help files for the PrismaView software and the module for information about configuring and managing the module. Platforms Supported PrismaView supports the following platforms: Windows 98 Windows NT Windows 2000 Windows XP Windows Vista In addition, there are Java versions of PrismaView for Linux and other Java-capable operating systems. iConfig Utility iConfig is a configuration utility in PrismaView that lets you quickly and easily complete the initial SNMP configuration of SNMP-manageable devices. You can use iConfig to perform any of the following tasks: Set the IP address, subnet mask, and default gateway Define the community strings and SNMP traps Upload new versions of unit software In addition, iConfig offers an authorized IP address system and access restriction to MIB groups supported by manageable devices. These extra layers of security do not affect SNMP compatibility in any way. Default Username and Password The default login information for both iConfig and Telnet is as follows: 4022582 Rev B 11 PrismaView and iConfig User ID: admin Password: admin For information on how to set or change passwords, see Basic Device Configuration (on page 22). Note: It is the responsibility of the network administrator to store and maintain the password lists. Dynamic Host Control Protocol (DHCP) The Prisma FiberLinX-II Gigabit module includes a Dynamic Host Control Protocol (DHCP) client. By default, the DHCP client is disabled. When a DHCP server is enabled on the network, the DHCP client will initiate a dialogue with the server during the boot-up sequence. The server will then issue an IP address, default gateway address, and subnet mask to the module. After the new IP address is received, the Prisma FiberLinX-II Gigabit module will reboot with the new IP address. When a DHCP server is not on the network, make sure that DHCP is disabled and use iConfig or serial configuration to manually set the IP addresses. Refer to Serial Configuration/Telnet Session (on page 21) for information on enabling and disabling DHCP. If an IP address is already assigned to the device, and DHCP is then enabled, that original IP address is saved. When DHCP is disabled, the saved IP address will be reinstated and the device will reboot. 12 4022582 Rev B PrismaView and iConfig LED Operation The Prisma FiberLinX-II Gigabit module features diagnostic LEDs. For example, the functions for a 1 x 9 fiber port version (SC) are shown below. 4022582 Rev B 13 Hardware Configuration Hardware Configuration Before installing the module in a chassis, you must select two features using the DIP switches: Enable or disable management on each port (DIP switch settings 1, 2, and 3) Configure the module as Standalone, a Host, or a Remote (DIP switch settings 7 and 8) These settings are explained in further detail below. DIP Switch Settings Before installing the module, use the DIP switches to set the hardware configurable features. The DIP switches are located on switch S1 on the card. Refer to the diagram and table below for switch settings and available features. Switch Function Default Setting 1 Management on EXT MGMT port ON 2 Management on DATA port OFF 3 Management on OPTICS or UPLINK port OFF 4 Factory use - do not change ---- 5 Factory use - do not change ---- 6 Factory use - do not change ---- 7 Remote module OFF 8 Host module OFF 9 Factory use - do not change ---- 0 Factory use - do not change ---- Host/Remote and Standalone Units The Prisma FiberLinX-II Gigabit module can be used as a Host, Remote, or Standalone unit. Refer to Application Examples (on page 40) for examples. When two modules are used as a pair, configure one as a Host unit (DIP switch 8 = On) and the other as a Remote unit (DIP switch 7 = On). 14 4022582 Rev B Hardware Configuration As a Host unit, the module requests management information from the attached Remote unit. It then displays that information, along with its own, when queried by SNMP. As a Remote unit, the module responds to requests for management information from an attached Host unit. The default configuration of the module is Standalone unit (DIP switches 7 and 8 = Off). Management Although the Prisma FiberLinX-II Gigabit module provides a twisted-pair port solely for management (EXT MGMT), you can configure the module to accept IPbased management traffic from any of its three ports. You can enable management on more than one port, or you can disable management on all ports, if desired. These switches limit only IP-based management. Host-to-Remote management is IPless and is never blocked from the fiber port. Serial port management of the unit is always available on the DB-9 port regardless of the DIP switch settings. In addition to defining which ports are used to manage the modules, the management DIP switch settings also define which ports the flow of Network Provider Management Domain traffic can take through the unit. By configuring a unique Management Domain, a Host/Remote pair of units can extend a secure-management LAN to a remote location to manage other equipment at the remote site. 4022582 Rev B 15 Installation Instructions Installation Instructions Each Prisma FiberLinX-II Gigabit module requires two slots in a Prisma MediaCenter chassis. Complete the following steps to install the module in a chassis. 1 Remove the blank faceplates covering the slots in which you want to install the module. 2 Slide the module into the chassis card guides until the module is seated securely in the connector. 3 Secure the module to the chassis by tightening the captive screw. The module includes on-board SNMP logic. A chassis other than a Prisma MediaCenter series cannot manage the module, so if installed in a different chassis, it must be managed independently. When installed in a Prisma MediaCenter chassis, you can manage the module from the chassis by using the Unified Management Agent (UMA). Modules not managed by UMA must have an IP address assigned to them after installation before they can be managed. Refer to Basic Device Configuration (on page 22) for details on assigning IP information. Small Form-Factor Pluggable (SFP) Ports Prisma FiberLinX-II Gigabit modules are available with one or two optional SFP ports. You must use a 1000 Mbps speed SFP for fiber connections or any gigabit copper SFP (1000 Mpbs to 10/100/1000 Mbps). In addition, many SFPs feature enhanced diagnostics capabilities with a Digital Diagnostics Monitoring Interface (DDMI). DDMI statistics provide real-time access to transceiver operating parameters such as voltage, temperature, laser bias current, and both transmitted and received optical power. To access DDMI information in PrismaView, click Tables > SFP Info. Note: Prisma FiberLinX-II Gigabit modules have been tested with SFP modules known to be MultiSource Agreement (MSA) compliant. Functionality of other SFP modules is not guaranteed due to possible non-conformity with MSA design standards. 16 4022582 Rev B Software Configuration Software Configuration The following sections describe the features that you can configure. Refer to the PrismaView online help for Prisma FiberLinX-II Gigabit module configuration information. To Assign IP Information When the Prisma FiberLinX-II Gigabit module is installed in a Prisma MediaCenter chassis, you can use UMA to manage the module without an IP address (see PrismaView online help for more information on UMA). When the module is not installed in a Prisma MediaCenter chassis, SNMP management is not accessible until the module IP information (e.g., IP address, subnet mask, etc.) is configured using iConfig, a serial port DB-9 connection, or DHCP. After assigning the module an IP address, you can use PrismaView or another SNMP-compatible network management system (NMS) to remotely configure, monitor, and manage the module. Auto-Negotiation, Duplex Mode, and Speed The DATA (non-SFP version) and EXT MGMT ports on the Prisma FiberLinX-II Gigabit module auto-negotiate for speed and duplex mode. The module also provides the option of selectively advertising or forcing the speed and duplex mode. See Port Configuration - port (on page 28) for details. AutoCross Feature for Twisted-Pair Connection All twisted-pair ports on the module include AutoCross, a feature that automatically selects between a crossover workstation and a straight-through connection depending on the connected device. See Port Configuration - port (on page 28) for details. Auto-Negotiation The module ships from the factory with auto-negotiation enabled on the twisted-pair and fiber ports. In this mode, the ports negotiate for speed and duplex. See Port Configuration - port (on page 28) for details. Forcing the Speed and Duplex Mode You can manually set the twisted-pair ports on the module for 10 Mbps or 100 Mbps operation at half or full duplex; for example, 10 Mbps full duplex, 10 Mbps half duplex, 100 Mbps full duplex, and so on. The OPTICS port operates at 100 Mbps full duplex. See Port Configuration - port (on page 28) for details. 4022582 Rev B 17 Software Configuration Selective Advertising Selective advertising, when used in combination with auto-negotiation, advertises only the configured speed and duplex mode for the twisted-pair port. If a specific speed or duplex mode is desired, use selective advertising rather than Force mode when connecting to devices that only use auto-negotiation. See Port Configuration port (on page 28) for details. Bandwidth Control The module includes bi-directional bandwidth control in increments of 244 Kbps at gigabit speed, configurable via PrismaView. This allows you to independently set the bandwidth limit from the DATA port to the OPTICS (or UPLINK) port and vice versa in a single-module application. Link Speed (Mbps) Speed Increments (Kbps) 10 4.88 100 48.8 1000 244 In a dual-module application, you can set it from the Host unit to the Remote unit and vice versa; that is, the bandwidth on the DATA ports on both the Host and Remote modules can be limited independently. Note: Management packets do not have priority over data packets. FX/TX LinkLoss and FiberAlert During normal operation, link integrity pulses are transmitted by all point-to-point Ethernet devices. When a Prisma FiberLinX-II Gigabit module receives valid link pulses, it registers that the device to which it is connected is active, and that the copper or fiber cable coming from that device is intact. The appropriate LNK (link) LED is lit to indicate this. For troubleshooting information when using the LinkLoss and FiberAlert features of the module, refer to Troubleshooting LinkLoss (on page 54) and Troubleshooting FiberAlert (on page 57). CAUTION: FiberAlert and LinkLoss features cause data interruptions designed to alert remote sites of line failures. These data interruptions can be misinterpreted as module failures when these features are enabled. Enable these features only when the resulting data interruptions and their causes are well understood. FX LinkLoss FX LinkLoss is a link integrity monitoring feature that forwards fiber link faults to the RJ-45 Data port to indicate that a fiber link fault has occurred. 18 4022582 Rev B Software Configuration TX LinkLoss TX LinkLoss is a link integrity monitoring feature that forwards an RJ-45 link fault to the fiber connected device to indicate that a link fault has occurred. FiberAlert FiberAlert minimizes the problems associated with the loss of one strand of fiber. Normally, when a single strand of fiber is lost, the transmitting side of the connection is unaware that there is a fault. FiberAlert returns faults on the same fiber on which they were received. Using LinkLoss and FiberAlert In a typical central site to remote site media conversion, it is recommended that you enable the LinkLoss and FiberAlert features as indicated in the following table. Feature Enabled Fault Location Port Affected FiberAlert Remote side only Fiber Fiber TX LinkLoss Remote side (or both) Twisted pair Fiber FX LinkLoss Host side (or both) Fiber Twisted pair CAUTION: When using Prisma FiberLinX-II Gigabit modules in pairs, do not enable FiberAlert on both modules. This will cause them to lock up when a fault occurs in the fiber. Only enable FiberAlert on the Remote module. Link Fault Pass-Through Link Fault Pass-Through (LFPT) is a troubleshooting feature that combines TX and FX LinkLoss from both the local and remote Prisma FiberLinX-II Gigabit modules. LFPT is enabled by turning on both FX and TX LinkLoss on both modules. This feature allows either end of the conversion to detect a link fault occurring at the other end of the media conversion chain. 1 A cable fault occurs on the remote twisted pair. 2 TX LinkLoss detects the fault and disables the OPTICS (or UPLINK) port. 3 FX LinkLoss detects the fiber loss and disables the DATA port. The link fault is passed through the media conversion and is observed at each end. It acts just like it would if the devices were directly connected. Note: FiberAlert can also be added to the remote side of the pair to further assist in locating a fault. 4022582 Rev B 19 Software Configuration Loopback Testing on Remote or Standalone The following functions are available during loopback testing. During loopback testing, management traffic entering the uplink port is still capable of managing the device. Address Swap A Layer 2 Ethernet switch will discard all received packets with the same MAC address as sent packets. To avoid this issue, the Loopback feature can swap the source and destination MAC addresses on the looped data. Address Swap and Clear Multicast Bit In addition to swapping the source and destination MAC addresses on the looped data, the Loopback feature can also be set to clear the multicast bit. This allows the looped data to avoid being blocked by any multicast settings. No Learning on OPTICS and DATA Ports The Loopback feature can be set to disable address learning on the OPTICS (or UPLINK) and DATA ports, allowing the loopback to be performed without interference from MAC address filtering functions. This is a function on the Host unit. Set the Remote unit for Loopback, and then set the Host to disable learning so Loopback frames pass from the OPTICS port to the DATA port. 20 4022582 Rev B Using Telnet Using Telnet Unless you are using UMA, you must assign the module an IP address before using a Telnet session. Refer to Basic Device Configuration (on page 22) for details on assigning IP information. All of the configurations that you can perform from the serial port can also be performed using a Telnet session. You can only use one Telnet session at a time. The following are the three levels for Telnet account access: User - can view status, change own password, and reboot. Operator - has all user privileges mentioned above, plus the ability to change settings. Administrator - has all operator privileges mentioned above, plus ability to add or delete accounts and re-initialize the unit to default settings (cleandb). Serial Configuration/Telnet Session The following sections describe serial configuration (including VLAN configuration), Telnet session configuration, and DHCP configuration. Note: Some screens may show TX and FX for the port titles where TX = DATA port and FX = OPTICS (or UPLINK) port. Serial Port (EXT MGMT) Note: The serial port (EXT MGMT) is always set to Administrator level. Your password for Telnet sessions is the password that you set and use in iConfig. Refer to iConfig Utility (on page 11) for more information. 4022582 Rev B 21 Using Telnet Basic Device Configuration After running through an initial self test, the message “Press <Enter> for Device Configuration” appears. When you press Enter, the main configuration screen opens as shown below. The following sections describe the information and options provided on this screen. Saved and Current Values The main configuration screen displays the following saved and current values: IP Address (IP address of SNMP agent) Subnet Mask (mask to define IP subnet to which agent is connected) Default Gateway (default router for IP traffic outside of the subnet) Server IP Address (TFTP server) New PROM File (TFTP new file name) Saved Values are the changes made during the current session, while Current Values are the values currently in use. Command List The following commands are available on this screen: 22 Command Description I Allows you to enter new Saved Values. P Allows you to change the password. * T Allows you to enter new trap destinations. K Allows you to remove all trap destinations. C Allows you to create SNMP community strings. 4022582 Rev B Using Telnet Command Description U Allows you to delete all SNMP community strings. E Allows you to end the session. * Reboot Allows you to reboot the unit (may result in short data loss). D Allows you to enable or disable DHCP. Space Bar Opens the device-specific configuration options screen. * Individuals with User-level rights can only view port status and port settings, change their password, end a session, and reboot the unit. Note: You must reboot the module after making any modifications to the Saved Values for your changes to take effect. To reboot, type reboot at the prompt on the Main Configuration screen, and then press Enter. (I) - Assign IP Information To assign the IP address and subnet mask, you must modify the Saved Values as follows: 1 At the main configuration screen, press I. 2 In the fields provided, enter the IP address for the connected device, and then press Enter. 3 In the fields provided, enter the subnet mask for the connected device, and then press Enter. You can now assign a default gateway to allow the unit to be visible beyond the local network, or press Enter to skip this step. Note: If a gateway is not defined, the module is visible only from the local network, not through the routers. When finished, press Enter, and then type reboot and press Enter for the changes to take effect. The Current Values on the Main Configuration screen are updated to match the Saved Values. (P) - Password Protect/Change Password Passwords have the following requirements: The password must be between 1 and 8 characters long. The password consists of a combination of any ASCII characters except spaces. Passwords are case-sensitive. To password-protect the serial port, press P in the Main Configuration screen. At the prompt, enter the password (do not use spaces), and then press Enter. You will then be asked for your password whenever you log on. 4022582 Rev B 23 Using Telnet To remove password protection, press P and then, instead of entering a password, press Enter. Notes: Passwords are a way to make the management of the network devices secure. It is your responsibility to store and maintain the password lists. If the passwords are lost, neither you nor we have a way to recover the lost password. Your password will need to be reset. Refer to the PrismaView and iConfig online help for more password information. If you forget the serial password, you must contact the support center for your area for assistance in resetting the password. See Support Telephone Numbers (on page 63). If you forget the iConfig username and password, you can launch a console session through the serial port, and then type in the command cleandb. If you forget both the serial and the iConfig passwords, you must contact the support center for your area for assistance. See Support Telephone Numbers (on page 63). (T) - Assign SNMP Trap Destinations Traps are sent by the manageable device to a management PC when a certain event takes place. Complete the following steps to enter a trap destination: 1 At the main configuration screen, press T. You will then be prompted to enter a new IP address. 2 At the prompt, type the IP address of the destination device, and then press Enter. 3 Type the name of the community string that the destination device has been configured to accept, and then press Enter. 4 Select whether the trap is for SNMP version 1 or 2c, and then press Enter. Note: This procedure enables all of the device traps. When you want to selectively activate and deactivate traps, use iConfig to configure your device. Supported traps include Link Down, Link Up, Cold Start, Warm Start, Last Gasp, and Authentication Failure. When deployed in pairs, Prisma FiberLinX-II Gigabit modules also support the following traps: Remote Unit Lost Remote Unit Found Far End TX Link Up Far End TX Link Down Remote Unit Cold Start 24 4022582 Rev B Using Telnet Remote Unit Warm Start (K) - Remove All SNMP Trap Destinations Complete the following steps to remove all trap destinations: 1 At the main configuration screen, press K. You will then be prompted to confirm that you want to delete all trap destinations. 2 At the prompt, press Y to continue, or press N to abort. 3 Press Enter to finish. Note: This procedure deletes all trap destinations. If you want to selectively delete trap destinations or select the type of trap reported or not reported, use iConfig to configure your device. (C) - Create SNMP Community Strings The default community string is named “public” and has read-write access. Before deleting the default community string, it is recommended that you create two custom community strings, one with read-only access for general use and another with read/write access for the administrator. Complete the following steps to create a new community string: 1 At the main configuration screen, press C. 2 Enter the name of the new community (up to 16 characters, no spaces), and then press Enter. 3 Type one of the following to assign access rights to the community string: R = read-only access W = read/write access Enter = abort (U) - Delete All SNMP Community Strings Complete the following steps to delete all community strings and start over. 1 At the main configuration screen, press U. You will then be prompted to confirm that you want to delete all community strings. 2 Press Y to proceed, or press N to abort. 3 Press Enter to finish. Note: This procedure deletes all community strings. If you want to selectively delete community strings, use iConfig to configure your device. (E) - End Your Session Press E to end the session before disconnecting the serial cable. This will stop the continuous stream of data that is sent to the serial port. 4022582 Rev B 25 Using Telnet (REBOOT) – Reboot Device To reboot the device, type reboot, and then press Enter. The device restarts, causing a temporary loss of operation while the unit re-initializes. (D) – Enable DHCP Press D to display a screen that allows you to enable or disable DHCP for the device. The DHCP client is disabled by default. Commands List (Space Bar) The Prisma FiberLinX-II Gigabit module also includes several device-specific options. To access these options, press the Space Bar from the Main Configuration screen, type the name of the action you want to perform (as shown below), and then press Enter. 26 Command Description See cleandb Allows reboot of the unit with a clean database. Clean Database cleandb (on page 27) download Downloads firmware from server IP address using TFTP. Download Files download (on page 27) ifstats Displays interface statistics. rmstats Displays RMON statistics. version Displays the firmware and hardware version information. reboot Reboots the unit. security Allows the non-standard network configuration. port Display or configure port status values. Port Configuration port (on page 28) 4022582 Rev B Using Telnet Command Description See config Configure VLAN and Transparent modes of operation. Mode Configuration config (on page 29) accounts Add or delete username/password accounts. Basic Device Configuration (on page 22) sysdescr Enter the MIB-II system description information. unit Display and change unit settings. Unit Configuration unit (on page 36) bw Display and change bandwidth settings. Bandwidth Configuration - bw (on page 37) sfpstats Display SFP diagnostics (SFP versions only). Clean Database - cleandb There are two levels of cleandb. The first level resets the Telnet or iConfig password and all of the SNMP database values. The second level additionally resets the IP address, IP Subnet, Gateway, VLAN settings, CLI command settings, serial port password, and security settings. Download Files - download The Prisma FiberLinX-II Gigabit module allows you to download firmware from a central server by using TFTP. Complete the following steps to download firmware using either a serial connection or a Telnet session. 4022582 Rev B 1 At the main configuration screen, enter the TFTP server IP address and the name of the PROM file you want to download (case-sensitive). 2 Reboot the unit to make these settings current. 3 Press the Space Bar from the Command List section in the main configuration screen. The Device-Specific Options screen appears. 4 Type download, and then press Enter. The Download a File screen appears with the IP Address of the TFTP server and the name of the file you want to download. Confirm that the server IP address and the filename are correct. 5 Press Enter to display the release notes. Use the space bar to page through the notes. 6 When you reach the end of the notes, press Y to start downloading the file. 7 The screen displays the progress of the download. Confirm that the download successfully (if not, an error message appears). 8 Press Q or F4 to return to the Device-Specific Options screen. 27 Using Telnet Note: When the module is installed in a managed chassis, you have option of using UMA to update the firmware. Refer to the PrismaView online help for more information on using UMA with iConfig, the Prisma MediaCenter chassis, and the Prisma FiberLinX-II Gigabit module. Port Configuration - port The Prisma FiberLinX-II Gigabit module allows you to view port status and configure some port features from a serial connection or a Telnet session. To access the Port Status/Control screen, type port in the Commands List, and then press Enter. The screen appears as shown below. In the Port Status Values area of this screen, you can view the link status, link lost counter, duplex status, and port speed. Note: Copper SFP settings in the Optics column may differ from those shown above. In the Port Control Settings area of the Port screen, you can access the settings described below. Port Enable This setting allows you to enable or disable the port. Both Port Enable and Admin Status must be enabled (enabled and up) to enable the port. This setting can be disabled from PrismaView. Admin Status This setting allows you to enable (Up) or disable (Down) the port. Both Port Enable and Admin Status must be enabled (enabled and up) to enable the port. This setting can be disabled from MIB-II compatible software. Port Speed Ctrl This selection allows you to set the port for auto-negotiation or to force one of the following speeds: 28 4022582 Rev B Using Telnet 10/100/1000 Mbps half duplex 10/100/1000 Mbps full duplex Advertise Ctrl Selective advertising is used in combination with auto-negotiation to advertise your selected speed and duplex mode for the DATA and EXT MGMT ports. This allows you to advertise all speeds and duplex modes. You must enable auto-negotiation for selective advertising to work. Note: If a specific speed or duplex mode is desired, it is recommended that you use selective advertising instead of Force mode (FO) when connecting to devices that can only auto-negotiate. For the FO uplink versions, the port is always force flow control 1000 FDX and cannot be changed. Advertise FlowC and Force FlowCtrl The following table lists the Advertise Control features available. Functionality Advertise FlowC Advertise FlowCtrl Auto-negotiation and flow control Adv Flow Flow Auto Auto-negotiation without flow control Adv No Flow N/A Flow control with force port speed (port speed control) Adv Flow Frc FlowCt In Port Control Settings, enable Unit FlowControl (described below), and then configure each port individually as appropriate. Press the Space Bar to toggle the function you want to enable. All RJ-45 ports feature Flow Control in full duplex and Back Pressure Flow control in half duplex. Back Pressure Flow Control is a hardware-based flow control that forces collisions on the line to limit bandwidth. Unit FlowControl This setting allows you to enable or disable Flow Control functionality on the unit. Before configuring each port individually, you must enable this global function. Mode Configuration - config The Prisma FiberLinX-II Gigabit module can be configured to allow several combinations of VLAN tagging and management. The most useful of these combinations are referred to as modes, and include the following: Default, for initial setup purposes only Transparent, for Untagged Management, Tagged Management, Extra Tagging (Q-in-Q) VLAN Defined, for Port VLAN, VLAN Filtering 4022582 Rev B 29 Using Telnet The applications of these modes are described in detail in Application Examples (on page 40). Note: Default mode, the factory default, is provided as a starting point from which to configure Prisma FiberLinX-II Gigabit modules. This mode does not provide adequate management isolation, and is not recommended for normal use. This section describes the Telnet or serial port screens and fields available for configuring the modes. To configure any of these modes, type config at the Device-Specific Options screen, and then press Enter. This opens either the Transparent Mode or VLAN Mode screen, depending on the current configuration. Transparent Mode The Transparent Mode screen is displayed when the module is configured in Default mode or Transparent mode. Transparent Mode Setup Screen Type Y on the Transparent Mode screen to display the Transparent Mode Setup screen, shown below. In this screen you can set the Extra Tag Mode. 30 4022582 Rev B Using Telnet Transparent Mode Setup This parameter lets you choose either to use all untagged data as the management domain, or to define a VLAN ID tag for the management domain. Type N to use all untagged data as the management domain. Type Y to define a VLAN ID tag for the management domain. If you choose to define a VLAN ID tag, this field expands to display the Management Tag field and the Management Priority field. CAUTION: If the device is currently managed on any port other than the EXT MGMT port, do not leave the Management Tag field defined as zero (0). This will disable management traffic on the module. You must enter a VLAN ID between 1 and 4094 (excluding the VLAN ID used for the Extra tag). Transparent with Extra-Tagging This parameter lets you choose whether to add a VLAN ID tag to all traffic, tagged or untagged, arriving on the DATA port. This ID can optionally be kept or removed when leaving the DATA port. If you choose to keep the tag, the unit only passes frames with this tag. Type Y to add these extra VLAN ID tags. Type N to avoid adding extra VLAN ID tags. 4022582 Rev B 31 Using Telnet If you choose to add extra tags, this field expands to display the Data Tag, Data Priority, and Leave Tags on Data Port fields. Transparent with VLAN Tag on EXT MGMT Port This parameter allows you to restrict the EXT MGMT port to only accept data tagged with the management VLAN ID by typing Y. 32 4022582 Rev B Using Telnet VLAN Mode Screen When you type N in the Transparent Mode Setup screen, the VLAN Mode screen appears as shown below. In this screen, you can set the following parameters: Default Mode Port VLAN on OPTICS (or UPLINK) port Port VLAN on DATA port Port VLAN Filter Management VLAN (available with all selections by default) Default Mode Typing N in the Tags column of both the Optics and Data rows will place the module in Default mode. No VLANs are defined, allowing only untagged packets to pass through the unit. Port VLAN on OPTICS (or UPLINK) Port This parameter allows you to restrict traffic to a single VLAN ID tag for the OPTICS (or UPLINK) port by typing Y in the Tags column of the Optics row. 4022582 Rev B 33 Using Telnet In the VLAN IDs - Saved column of the Data row, type the VLAN ID tag to be used (13 in this example). This VLAN ID will be added to all untagged traffic entering the DATA port and removed from all traffic leaving the DATA port. Port VLAN on DATA Port This parameter allows you to restrict traffic to a single VLAN ID tag for the DATA port by typing Y in the Tags column of the Data row. In the VLAN IDs - Saved column of the Optics row, type the VLAN ID tag to be used (13 in this example) This VLAN ID will be added to all untagged traffic entering the OPTICS (or UPLINK) port and removed from all traffic leaving the OPTICS (or UPLINK) port. 34 4022582 Rev B Using Telnet Port VLAN Filter This parameter allows you to pass traffic with up to 32 separate VLAN IDs between the OPTICS (or UPLINK) port and the DATA port. To enable the Data VLANS fields, type Y in the Tags column for both the Optics and Data rows. Then enter up to 32 VLAN IDs in the Data VLANs fields, plus one for SNMP. Management VLAN and EXT MGMT Tag This selection is available for all VLAN modes except for the default mode. To configure a VLAN ID for management traffic, type the ID in the VLAN IDs – Saved column of the SNMP row (200 in this example). The EXT MGMT tag parameter provides the option of adding the defined Management VLAN ID to all untagged traffic entering the EXT MGMT port (EXT Mgmt Tag = N) or restricting the EXT MGMT port to pass only traffic bearing this VLAN ID (EXT Mgmt Tag = Y). CAUTION: If the device is currently managed on any port other than the EXT MGMT port, do not leave the Management Tag field defined as zero (0). This will disable management traffic on the module. You must enter a VLAN ID between 1 and 4094 (excluding the VLAN IDs used for the Port VLAN or the Data VLANs). 4022582 Rev B 35 Using Telnet Unit Configuration - unit The Prisma FiberLinX-II Gigabit module allows you to view unit status as well as configure some unit features by using a serial connection or Telnet session. In the Main Configuration screen, press the Space Bar, type unit, and then press Enter. The Unit Control Settings screen opens as shown below. In this screen, you can view the unit FlowControl, FiberAlert/LinkLoss, Loopback, Maximum Frame Size, and 802.1p Base Priority. Note: Logging in as a User in a Telnet session allows you to view these settings, but prevents you from changing them. Unit FlowControl This setting allows you to enable or disable Flow Control functionality on the unit. You must enable this to use Flow Control on any port. The settings include the following: Disable FlowControl Globally Enable FlowControl If Port Allows Unit FiberAlert This setting allows you to enable or disable FiberAlert and LinkLoss functionality on the unit. The settings include: No FiberAlert Or LinkLoss Enabled FXLinkLoss Only, Enabled TXLinkLoss Only, Enabled FiberAlert Plus FXLinkLoss Enabled FiberAlert Plus TXLinkLoss Enabled TXLinkLoss Plus FXLinkLoss Enabled TXLinkLoss + FXLinkLoss + FiberAlert Enabled FiberAlert Only 36 4022582 Rev B Using Telnet Unit LoopBack This setting allows you to enable or disable Loopback functionality on the unit. The settings include the following: No LoopBack, Normal Traffic Mode LoopBack Enabled LoopBack, Src/Dest Address Swap LoopBack, Address Swap, Clear Multicast bit No Learning on OPTICS (or UPLINK) or DATA Ports Unit Max FrameSz This setting allows you to enter the maximum frame size on the unit by using the number keys. The valid values are 1518 to 12196. 802.1p Base Pri This parameter allows you to set the threshold between low and high priority on the unit. For example, when the Base VLAN Priority is set to 4, priority settings of 0 through 3 are low priority and settings of 4 through 7 are high priority. When the Base VLAN Priority is set to 3, priority settings of 0 through 2 are low priority and priority settings of 3 through 7 are high priority. Boot Trap Delay, Seconds This parameter allows you to set the number of seconds before a Warm Start trap is sent by the agent; for example, 0. Bandwidth Configuration - bw The Prisma FiberLinX-II Gigabit module allows you to view bandwidth status and to configure bandwidth from a serial connection or Telnet session. In the Main Configuration screen, press the Space Bar, type bw, and then press Enter. The Bandwidth Control Setting screen opens as shown below. This screen includes the following parameters: 4022582 Rev B 37 Using Telnet Receive Bandwidth Limit (policing) Transmit Bandwidth Limit (shaping) Unit Rate Control RX Bandwidth Limit This parameter allows you to set the receive bandwidth limit (up to 1000 Mbps) for both the DATA and OPTICS (or UPLINK) ports. Entering a setting of either 0 or 1,000,000,000 will result in a limit of 1000 Mbps. When the received data reaches the set limit in a one-second interval, the unit stops receiving data. If flow control is enabled, flow control begins prior to reaching the set limit. TX Bandwidth Limit This parameter allows you to set the transmit bandwidth limit (up to 1000 Mbps) for both the DATA and OPTICS (or UPLINK) ports. Entering a setting of either 0 or 1,000,000,000 will result in a limit of 1000 Mbps. When the transmit data reaches the set limit in a one-second interval, the unit stops transmitting but continues to receive data until all the internal buffers are filled. If flow control is enabled, flow control begins before all the buffers are filled. Note: Do not set both the RX and TX Bandwidth limits at the same time. Unit RateControl Enable/Disable This parameter allows you to enable or disable the bandwidth limiting feature on this unit. 38 4022582 Rev B Application Overview Application Overview Before using the Prisma FiberLinX-II Gigabit module in your network, decide the following: Will modules be located at only one or at both ends of the fiber? How do you want to manage the modules? Will you define VLAN IDs? How Many Modules? How many Prisma FiberLinX-II Gigabit modules will you use? Two modules are recommended for Host/Remote applications. This will allow for IP-less management, providing greater security (only with an SNMP management module). One module is recommended for a single-unit application. This option requires an assigned IP address for management. How to Manage Them? You can manage a Prisma FiberLinX-II Gigabit module through any of its three ports, through any combination of these ports, or from the chassis. Using only the EXT MGMT port or UMA provides the highest level of security. If management must be through either the DATA port or the UPLINK port, a unique VLAN tag is recommended to maintain security. Will You Define VLAN IDs? To use VLAN traffic with specific tags on any or all of the DATA ports, you must disable Transparency and define VLAN IDs as explained in the VLAN configuration sections to follow. To use VLAN tagged, untagged, or double-tagged traffic, enable Transparency. To use only untagged traffic, set the unit to Default mode. 4022582 Rev B 39 Application Examples Application Examples The following are application examples of the different VLAN configuration modes available using the Prisma FiberLinX-II Gigabit module. If you need assistance configuring an application, contact Customer Support. See Support Telephone Numbers (on page 63). The application modes include the following: Default Transparent with untagged management Transparent with tagged management Transparent with extra tagging (Q-in-Q) Port VLAN Port VLAN filter Note: When configuring VLAN IDs, remember that you can use any VLAN ID between 1 and 4,094. The VLAN IDs used in the following applications are for example purposes only. Default Default mode passes only untagged data between the DATA port and the OPTICS (or UPLINK) port. This mode is the factory default and is provided as a starting point from which to configure the Prisma FiberLinX-II Gigabit module. It is not intended as a mode for normal use. Note: Default mode does not provide any management traffic protection, and is not recommended for normal use. Transparent with Untagged Management Transparent with Untagged Management mode passes tagged traffic between the DATA port and the OPTICS (or UPLINK) port and allows untagged traffic to be considered as management domain traffic (untagged). Complete the following steps to configure this mode: 40 4022582 Rev B Application Examples 4022582 Rev B 1 Set the management DIP switch ON for the ports using management. In the example shown below, it is the OPTICS (or UPLINK) port: 3 = ON. To enable External Management (EXT MGMT), set DIP Switch 1 to ON. Otherwise, leave DIP Switch 1 in the OFF position (default from factory) to disable EXT MGMT. 2 Set Transparent Mode to allow both tagged data and untagged management traffic to pass: a In the Main Configuration screen, press the Space Bar, type config, and then press Enter. The Configuration screen appears as shown below. b Type Y in the Transparent Mode field and press any key except S or Q. The Transparent Mode Setup screen appears as shown below. 41 Application Examples c Type S or press F3 to save without setting any transparent mode options. This sets all untagged traffic as management (Is a VLAN tag required on Management packets? [ N ]). d Type reboot, and then press Enter. In this mode, both tagged and untagged data can pass from the OPTICS and DATA ports. If the EXT MGMT DIP switches are enabled, untagged packets are allowed access to management. Note: The flow of management domain traffic is defined by the DIP switches. For example, if the management DIP switches are on the OPTICS and DATA ports, management domain traffic is allowed to flow through those ports. Transparent with Tagged Management Transparent with Untagged Management mode passes both tagged and untagged traffic between the DATA port and the OPTICS (or UPLINK) port. By using a VLAN Tag, you can isolate and route the management path in the module. This method can be used with or without continuing the management path down the EXT MGMT port. Complete the following steps to configure this mode: 42 1 Set the management DIP switch ON for the ports using management. In the example shown below, it is the OPTICS (or UPLINK) 3 = ON and EXT MGMT 1 = ON. 2 Set Transparent Mode to allow both tagged and untagged traffic to pass: 4022582 Rev B Application Examples a In the Main Configuration screen, press the Space Bar, type config, and then press Enter. The Configuration screen appears as shown below. b Enter Y in the Transparent Mode field and press any key except S or Q. The Transparent Mode Setup screen appears as shown below. c Type Y in the Is a VLAN tag required on management packets? field. The screen displays the management tag fields: Is a VLAN tag required on Management packets? [ Y ] The Management Tag is [0 ] Management Priority is [0 ] d Enter the management tag (VLAN ID) and the priority (optional), as shown in the example below: Is a VLAN tag required on Management packets? [ Y ] The Management Tag is [7 ] Management Priority is [0 ] e Confirm that the Are VLAN Tags required on the EXT port? field is set to N, as shown in the example below: Are VLAN Tags required on the EXT Port? [ N ] 4022582 Rev B f Type S or press F3 to save the settings. This sets all traffic with VLAN ID 7 as management. g Type reboot, and then press Enter. 43 Application Examples The module is now configured to pass all data between the OPTICS (or UPLINK) and DATA ports except for data that is tagged with VLAN ID 7. All data tagged VLAN ID 7 is considered management traffic and passes from the OPTICS (or UPLINK) port to the EXT MGMT port only. The module is configured to receive untagged data from the twisted pair EXT MGMT port and add the VLAN ID 7 before sending it out the OPTICS (or UPLINK) port. In this mode, the EXT MGMT port provides a secure link to the management port at the other end of the fiber link. Transparent with Extra Tagging (Q-in-Q) Transparent with Extra Tagging mode can add an extra tag to data received on the DATA port. By using Extra Tagging in a Host/Remote module pair, all data received on the Remote module DATA port can be extra-tagged and sent from the Host module DATA port with a unique tag for identification in the Host cloud. In the reverse direction, the extra tag is removed before sending the data from the Remote module DATA port. To configure this mode, you must set Extra Tag mode on both Prisma FiberLinX-II Gigabit modules. Complete the following steps to configure this mode: 1 44 In the Main Configuration screen, press the Space Bar, type config, and then press Enter. The Configuration screen appears as shown below. 4022582 Rev B Application Examples 2 Type Y in the Transparent Mode field, and then press any key except S or Q. The Transparent Mode Setup screen opens as shown below. 3 Type Y in the Do you want to enter the Extra Tag mode? field. The screen expands to display the Extra Tag mode fields: Do you want to enter the Extra Tag mode? Enter Y for Extra Tagging. Enter N if you do not want Extra Tags [ Y ] The Data Tag is [0 ] Data Priority is [0 ] Are Extra Tags left on the Data Port? [ N ] 4 Type the extra tag VLAN ID (for example, 8), the Priority (optional), and the EtherType (optional). These values must be identical on both Prisma FiberLinX-II Gigabit modules. The Data Tag is [8 ] Data Priority is [0 ] Are Extra Tags left on the Data Port? 4022582 Rev B [ N ] 5 On the Host module, type Y in the Are Extra Tags left on the Data Port? field to only accept the Extra Tag VLAN ID on the DATA port. 6 On the Remote module, type N to have the Extra Tag VLAN ID added to incoming and removed from outgoing data on the DATA port. 7 Press S or F3 to save the settings. 8 Type reboot, and then press Enter to re-initialize the module. 9 Repeat steps 1-8 above for second module. 45 Application Examples The Host/Remote module pair is now configured to pass only VLAN ID 8 data from the Host module to the Remote module. VLAN ID 8 tagging is removed before sending the data from the Remote DATA port. The Extra Tag VLAN ID 8 is added to all data received on the Remote DATA port before being sent to the Host module, where the VLAN ID 8 tag remains on the data leaving the Host DATA port. Port VLAN The Port VLAN mode allows you to configure the module to accept only data tagged with one specific VLAN ID. This mode can be configured for either the OPTICS (or UPLINK) port or the DATA port. VLAN on DATA Port - Configuration Complete the following steps to configure this mode: 46 4022582 Rev B Application Examples 1 In the Main Configuration screen, press the Space Bar, type config, and then press Enter. The Configuration screen appears as shown below. 2 Type N in the Transparent Mode field, and then press any key except S or Q. The VLAN screen opens as shown below. 3 Type Y in the Tags column of the Data row, and then enter a VLAN ID in the VLAN IDs Current column of the OPTICS row (for example, 13). VLAN IDs Current Saved Ports Optics Data 4 [0 [0 ] ] [13 [0 ] ] Priorities Current Saved [0 [0 ] ] [0 [0 ] ] Tags Data VLANs are used only [ N ] if Tags are enabled on both [ Y ] the Optics and Data Ports. Type Y in the SNMP field. VLAN IDs Current Saved Priorities Current Saved Tags Ports Data VLANs are used only Optics [0 ] [13 ] [0 ] [0 ] [ N ] if Tags are enabled on both Data [0 ] [0 ] [0 ] [0 ] [ Y ] the Optics and Data Ports. Management VLAN.........................EXT Mgmt Tag SNMP....[0 ] [20 ] [0 ] [0 ] [ Y ] 4022582 Rev B 5 Type S or press F3 to save the settings. 6 Type reboot, and then press Enter to re-initialize the module. 47 Application Examples The Prisma FiberLinX-II Gigabit module is now configured to pass only VLAN ID 13 from the DATA port to the OPTICS (or UPLINK) port. Untagged packets arriving at the OPTICS (or UPLINK) port (Tags = N) receive a tag (VLAN ID = 13) before being sent out of the DATA port. The VLAN ID number used for a port must be different from the number used for the Management VLAN ID tag (VLAN ID=20). The EXT MGMT must have VLAN=20. Note: If you entered Y in the EXT MGMT Tag field, the VLAN ID for this port is the value in the Management VLAN field, so you must also define a VLAN ID in the Management VLAN field. If the unit is managed through the EXT MGMT port using untagged frames, you do not need to define the Management VLAN. VLAN on OPTIC Port - Configuration Complete the following steps to configure the module: 48 4022582 Rev B Application Examples 1 In the Main Configuration screen, press the Space Bar, type config, and then press Enter. The Configuration screen appears as shown below. 2 Type N in the Transparent Mode field, and then press any key except S or Q. The VLAN screen opens as shown below. 3 Type Y in the Tags column of the Optics row, and then type a VLAN ID in the VLAN IDs Current column of the Data row (for example, 13). VLAN IDs Current Saved Ports Optics Data 4 [0 [0 ] ] [0 [13 ] ] Priorities Current Saved [0 [0 ] ] [0 [0 ] ] Tags Data VLANs are used only [ Y ] if Tags are enabled on both [ N ] the Optics and Data Ports. Type a VLAN ID in the Management VLAN IDs field. VLAN IDs Current Saved Priorities Current Saved Tags Ports Data VLANs are used only Optics [0 ] [13 ] [0 ] [0 ] [ N ] if Tags are enabled on both Data [0 ] [0 ] [0 ] [0 ] [ Y ] the Optics and Data Ports. Management VLAN.........................EXT Mgmt Tag SNMP....[0 ] [20 ] [0 ] [0 ] [ N ] 4022582 Rev B 5 Type S or press F3 to save the settings. 6 Type reboot, and then press Enter to re-initialize the module. 49 Application Examples The Prisma FiberLinX-II Gigabit module is now configured to pass only VLAN ID 13 from the OPTICS (or UPLINK) port to the DATA port. Untagged packets arriving at the DATA port (Tags = N) receive a tag (VLAN ID = 13) before being sent out of the OPTICS (or UPLINK) port. The VLAN ID number used for a port must be different from the number used for the Management VLAN ID. Management of a host unit through the external port requires an IP address on the host unit. A remote unit connected over the fiber link is managed through the local unit using internal IP-less communication. If direct IP management of remote units is required, then DIP switch #3 must be ON and the remote must have an IP address. Port VLAN Filter The VLAN filter mode allows you to isolate a segment of the network to only accept data using some or all of the 32 available VLAN IDs. Complete the following steps to configure this mode: 50 4022582 Rev B Application Examples 1 In the Main Configuration screen, press the Space Bar, type config, and then press Enter. The Configuration screen appears as shown below. 2 Type N in the Transparent Mode field, and then press any key except S or Q. The VLAN screen opens as shown below. 3 Type Y in the Tags column of both the Optics row and the Data row to enable Data VLANs. VLAN IDs Current Saved Ports Optics Data 4022582 Rev B [0 [0 ] ] [0 [0 ] ] Priorities Current Saved [0 [0 ] ] [0 [0 ] ] Tags Data VLANs are used only [ Y ] if Tags are enabled on both [ Y ] the Optics and Data Ports. 4 Type a VLAN ID in the Management VLAN IDs field, and then enter up to 32 VLAN IDs in the Data VLANs rows. VLAN IDs can range from 1 to 4094. Only the VLANs in this list will pass through the unit. 5 Type S or press F3 to save the settings. 51 Application Examples 6 Type reboot, and then press Enter to re-initialize the module. The Prisma FiberLinX-II Gigabit module is now configured to pass only packets with tags containing the VLAN IDs defined in the Data VLANs table. VLAN ID numbers defined in this table must not be the same as the number used for the Management VLAN ID. 52 4022582 Rev B Troubleshooting Troubleshooting General Troubleshooting If two Prisma FiberLinX-II Gigabit Host/Remote units are not communicating properly, make sure one is a Host (DIP switch #8) and the other is a Remote (DIP switch #7). If the second unit is not configured as a Remote, it will be recognized as a Standalone unit and the Host and Remote units will not communicate with each other properly. Setting the OPTICS (or UPLINK) port management DIP switch #3 to the ON position on both modules will allow you to perform a simple ping test. This is possible only if pinging from the computer through the optics UPLINK port, which is highly unusual. You must enable the EXT or DATA switch and connect to the computer to ping either device. If you cannot establish a link on a twisted pair port, make sure that the cable is in working order; if not, replace the cable. The Prisma FiberLinX-II Gigabit module includes AutoCross, so you should detect a link regardless of the Cat5 E cable type. If you cannot establish a fiber link, make sure that the fiber transceivers on the module are not over- or under-driving the fiber receivers. Make sure that the fiber mode and wavelength on both modules match (e.g., both are 1310 nm single-mode fiber). Make sure that the port speeds on the module match those on the end devices connected to the module. Configure all connected devices for auto-negotiation, or if using Force mode, confirm that speed and duplex settings match. If using single-strand fiber, make sure that the pair of devices is compatible single-strand fiber devices. For example, a Prisma FiberLinX-II Gigabit TX/SSFXSM1310-SC that transmits 1310 nm and receives 1550 nm must be connected to a device which transmits 1550 nm and receives 1310 nm. If using a module with an SFP port and it is not functioning properly or at all, make sure that the installed SFP module is the correct speed (1000 Mbps). When using the FiberAlert feature, make sure that FiberAlert is enabled on only one unit when connecting two modules, or when connecting a Prisma FiberLinXII Gigabit to another media converter that includes the FiberAlert feature. If management is not functioning properly, make sure that the DIP switch settings are accurate for the port you want to manage. To restore the unit to factory default settings, use the cleandb function via the serial port. This is especially helpful if you feel that you have configured the module improperly. If restarting to factory defaults is necessary, use this function on both units in Host/Remote applications, and then reconfigure all 4022582 Rev B 53 Troubleshooting settings. Confirm that the READ/WRITE Community Strings for the module and PrismaView are the same. Troubleshooting LinkLoss The following sections show and explain the different troubleshooting configurations for the Prisma FiberLinX-II Gigabit module. Normal Operation The Prisma FiberLinX-II Gigabit module also sends out link pulses from its copper and fiber transmitters. Normally, however, the module has no way of knowing whether the cable to the other device is intact and the link pulses are reaching the other end. The combination of FiberAlert and LinkLoss allows this information to be obtained even when physical access to a remote device is not available. 54 4022582 Rev B Troubleshooting FX LinkLoss Normally, when a fault occurs on the fiber segment of a Prisma FiberLinX-II Gigabit conversion, only the fiber port LEDs on the modules indicate a fault. None of the devices connected to the RJ-45 ports are aware of the fault. When FX LinkLoss is enabled on the module, the fiber fault is forwarded to that module's RJ-45 connection. This turns off the link on the RJ-45 port, which can then be detected by the connected device. 4022582 Rev B 55 Troubleshooting TX LinkLoss When a fault occurs on a twisted pair segment joining a device to a Prisma FiberLinX-II Gigabit module, the link fault is not detected by the device connected to the module by fiber. 56 4022582 Rev B Troubleshooting When TX LinkLoss is enabled on the Remote module, a twisted pair fault turns off the fiber port transmitter. This allows the fiber-connected device to detect a link fault. When the fiber uplink port is set to AN, the LED is OFF. Troubleshooting FiberAlert CAUTION: Do not enable FiberAlert at both ends. This can cause the fiber link to lock up. 4022582 Rev B 57 Troubleshooting When FiberAlert is enabled on the Remote module (preferred use), a fault on the receive side of the OPTICS (or UPLINK) port causes the transmitter side to turn off. This allows the fiber connected device to detect a fault in its transmission fiber. 58 4022582 Rev B Troubleshooting Troubleshooting Link Fault Pass-Through 4022582 Rev B 59 Serial Port Pinout Serial Port Pinout The Prisma FiberLinX-II Gigabit features a serial port that uses an IBM-compatible DB-9 serial connector. To connect the module to your workstation, use a straight-through (pin-to-pin) cable. If your workstation has a serial port using a connection not compatible with a DB-9 COM port, use the following pin connection chart for reference in making a cable. Pin Signal 2 Transmit (out) 3 Transmit (in) 5 Ground 1, 4, 6-9 Reserved CAUTION: Use shielded cable with the Prisma FiberLinX-II Gigabit to maintain EMI/RFI compliance. Make sure that the cable length is less than 50 ft (15.24 m). Plug one end of the cable into the DB-9 connector on the Prisma FiberLinX-II Gigabit module and the other into the appropriate port on your workstation. Set your workstation for VT-100 emulation. The serial port settings on the workstation should be as follows: 38.4K baud 8 data bits 1 stop bit No parity No flow control 60 4022582 Rev B Fiber Optic Cleaning Guidelines Fiber Optic Cleaning Guidelines Optical Connector Cleaning Overview Cleaning fiber-optic connectors can help prevent interconnect problems and therefore aid system performance. When optical connectors are disconnected and reconnected, the fiber surface can become dirty or scratched. The goal of cleaning the fiber optic connectors is to remove all dust and contaminants without leaving any residue. Recommended Equipment The following equipment is recommended to clean the ends of fiber-optic connectors. CLETOP or OPTIPOP ferrule cleaner (CLETOP Type A for SC, Type B for LC) Compressed air (also called “canned air”) Lint-free wipes moistened with optical-grade (99%) isopropyl alcohol Bulkhead swabs for LC or SC type connectors (choose appropriate type) Optical connector scope Tips for Optimal Fiber-Optic Connector Performance Follow these guidelines to ensure optimal connector performance. Do not connect or disconnect optical connectors while optical power is present. Always use compressed air before cleaning the fiber-optic connectors. Always use end caps on connectors when they are not in use. Always use compressed air to clean the end caps. If you have any degraded signal problems, clean the fiber-optic connector. Advance a clean portion of the ferrule cleaner reel for each cleaning. Turn off optical power before making or breaking optical connections in order to avoid microscopic damage to fiber mating surfaces. 4022582 Rev B 61 Fiber Optic Cleaning Guidelines To Clean Optical Connectors Warning: Avoid personal injury! Use of controls, adjustments, or procedures other than those specified herein may result in hazardous radiation exposure. Avoid personal injury! The laser light source on this equipment (if a transmitter) or the fiber cables connected to this equipment emit invisible laser radiation. Avoid personal injury! Viewing the laser output (if a transmitter) or fiber cable with optical instruments (such as eye loupes, magnifiers, or microscopes) may pose an eye hazard. Do not apply power to this equipment if the fiber is unmated or unterminated. Do not stare into an unmated fiber or at any mirror-like surface that could reflect light emitted from an unterminated fiber. Do not view an activated fiber with optical instruments (e.g., eye loupes, magnifiers, microscopes). Use safety-approved optical fiber cable to maintain compliance with applicable laser safety requirements. Important: Ensure that no optical power is present prior to this procedure. 1 Turn optical power off to the connector. 2 Using an optical connector scope, inspect the connector for scratches, burns, or other signs of damage. Note: If the connector is damaged, replace the jumper. 3 If the connector requires cleaning, swipe it across the face of the appropriate ferrule cleaner several times. Result: This will remove dust and some films. Note: You may hear a slight "squeak" while cleaning the connector, indicating that it is clean. 62 4 Inspect the connector again. If the connector requires further cleaning, clean it using 99% isopropyl alcohol and a lint free wipe. 5 Swipe the connector across the face of the appropriate ferrule cleaner several more times to remove any film left by the alcohol. 6 Repeat all the steps above as needed until the connector is clean. 4022582 Rev B For Information For Information Support Telephone Numbers This table lists the Technical Support and Customer Service numbers for your area. Region Centers North America Cisco Services Atlanta, Georgia United States Telephone and Fax Numbers For Technical Support, call: Toll-free: 1-800-722-2009 Local: 678-277-1120 (Press 2 at the prompt) For Customer Service or to request an RMA number, call: Europe, Middle East, Africa Belgium Toll-free: 1-800-722-2009 Local: 678-277-1120 (Press 3 at the prompt) Fax: 770-236-5477 E-mail: customer.service@sciatl.com For Technical Support, call: Telephone: 32-56-445-197 or 32-56-445-155 Fax: 32-56-445-061 For Customer Service or to request an RMA number, call: Telephone: 32-56-445-444 Fax: 32-56-445-051 E-mail: elc.service@sciatl.com Japan Japan Telephone: 81-3-5908-2153 or +81-3-5908-2154 Fax: 81-3-5908-2155 E-mail: yuri.oguchi@sciatl.com Korea Korea Telephone: 82-2-3429-8800 Fax: 82-2-3452-9748 E-mail: kelly.song@sciatl.com China (mainland) China Telephone: 86-21-2401-4433 Fax: 86-21-2401-4455 E-mail: xiangyang.shan@sciatl.com All other Asia-Pacific countries & Australia Hong Kong Telephone: 852-2588-4746 Fax: 852-2588-3139 E-mail: support.apr@sciatl.com Brazil Brazil For Technical Support, call: Telephone: 55-11-3845-9154 ext 230 Fax: 55-11-3845-2514 For Customer Service or to request an RMA number, call: Telephone: 55-11-3845-9154, ext 109 Fax: 55-11-3845-2514 E-mail: luiz.fattinger@sciatl.com 4022582 Rev B 63 For Information Region Centers Telephone and Fax Numbers Mexico, Central America, Caribbean Mexico For Technical Support, call: Telephone: 52-3515152599 Fax: 52-3515152599 For Customer Service or to request an RMA number, call: Telephone: 52-55-50-81-8425 Fax: 52-55-52-61-0893 E-mail: karla.lugo@sciatl.com All other Latin America countries Argentina For Technical Support, call: Telephone: 54-23-20-403340 ext 109 Fax: 54-23-20-403340 ext 103 For Customer Service or to request an RMA number, call: Telephone: 770-236-5662 Fax: 770-236-5888 E-mail: veda.keillor@sciatl.com 64 4022582 Rev B 5030 Sugarloaf Parkway, Box 465447 678-277-1000 Lawrenceville, GA 30044 Cisco, Cisco Systems, the Cisco logo, the Cisco Systems logo, PrismaView, MediaCenter, and Prisma are registered trademarks or trademarks of Cisco Systems, Inc. and/or its affiliates in the U.S. and certain other countries. All other trademarks mentioned in this document are the property of their respective owners. Product and service availability are subject to change without notice. © 2009 Cisco Systems, Inc. All rights reserved. Printed in United States of America February 2009 Part Number 4022582 Rev B