ALD XAVIER UNIVERSITY REAG HIGHW AGAN LD RE A N O R 126 AN H 126 IGHW A 126 Y 42 75 27 71 127 22 NOR WO OD LA TER 562 74 AL 50 75 22 27 71 42 50 71 50 27 50 75 CINCINNATI 471 71 127 27 75 42 27 CINCINNATI, OH XAVIER UNIVERSITY 3824 LEDGEWOOD DRIVE CINCINNATI, OHIO 45207 KUHLMAN HALL RENOVATION PHASE III 22 AY RON 126 50 SITE LOCATION DATE XAVIER UNIVERSITY 3824 LEDGEWOOD DRIVE CINCINNATI, OHIO 45207 71 42 127 - KUHLMAN HALL RENOVATION PHASE III 75 27 PROJECT SUMMARY REVISION KUHLMAN HALL IS A 7-STORY BRICK, CMU, AND CONCRETE STRUCTURE CONSTRUCTED IN 1966. KUHLMAN HALL IS CONNECTED TO HUSMAN HALL, BUILT 1964, AND SEPARATED BY A 12'-0" WIDE BREEZEWAY. HUSMAN HALL MECHANICAL AND ELECTRICAL SYSTEMS ARE FED THROUGH KUHLMAN HALL. - ISSUE R:\PLANT\DESIGN PROJECTS\KUHLMAN HALL\KUHLMAN 2015 PHASE III - REVISED\SHEETS\G001 COVER SHEET.DWG - SCOPE OF THIS PROJECT: 1. WORK ASSOCIATED WITH ELEVATOR MODERNIZATION XAVIER UNIVERSITY CAMPUS SHEET INDEX SHEET NO SHEET TITLE OFFICE OF PHYSICAL PLANT XAVIER UNIVERSITY 3800 VICTORY PARKWAY CINCINNATI, OH 45207 513-745-2037 G001 COVER SHEET LS100 LIFE SAFETY PLANS LS101 LIFE SAFETY PLANS A100 NEW GROUND FLOOR A107 ROOF AND ELEVATOR MACHINE ROOM PLAN HD107 H.V.A.C. - DEMOLITION - ROOF HV107 H.V.A.C. - NEW DUCTWORK - ROOF HV500 H.V.A.C. - COMCHECK E000 ELECTRIC LEGEND ED100 ELECTRIC DEMOLITION - GROUND FLOOR ED107 ELECTRIC DEMOLITION - ROOF E100 ELECTRIC - GROUND FLOOR RACHEL E. BIESIK, LICENSE #11710 EXPIRATION DATE: 12/31/2015 E107 ELECTRIC - ROOF DRAWN BY: CHECKED BY: E201 ELECTRICAL SCHEDULES JKF REB E300 ELECTRICAL SINGLE-LINE DIAGRAM COVER SHEET 4/17/2015 10:48 AM PROJECT NUMBER 911723 DATE APRIL 17, 2015 SHEET NO. G001 1 HR FIRE-RATED PARTITION 2 HR FIRE RATED BARRIER 2 HR FIRE-RATED VERTICAL SHAFTS INCIDENTAL OCCUPANCY AREA IS SPRINKLERED FE EXIT SIGN (EXISTING) FE - FIRE EXTINGUISHER FEC - FIRE EXTINGUISHER CABINET (EXISTING) (EXISTING) FEC ELEVATOR LOBBY PART OF EXIT ACCESS INCIDENTAL OCCUPANCY AREA IS SPRINKLERED FEC FEC EXISTING CONDITIONS USE GROUP = R-2 CONSTRUCTION TYPE = 1B (NON-COMBUSTIBLE.) 1 GROUND FLOOR LIFE SAFETY PLAN STORIES = 7 1/16" = 1'-0" FIRE PROTECTION SYSTEMS AUTOMATIC SPRINKLER SYSTEM: BUILDING IS PARTIALLY SPRINKLERED, NO CHANGE AUTOMATIC FIRE ALARM SYSTEM: INSTALLED THROUGHOUT. ACCESSIBLE ENTRANCE (1 OF 2 MAIN ENTRANCES) SLABS. 2 HOURS MINIMUM. SEE LIFE SAFETY DRAWINGS. GROUND = MINUS MINUS MINUS FEC 1ST = MINUS 2ND = MINUS MINUS FEC ELEVATOR LOBBY 13, 150 SF 12, 656 SF 25, 807 SF OCCUPANT LOAD 11,969 SF (TOTAL) 1,040 SF (ACCESSORY STORAGE) 4 914 SF (MECH. EQUIP. ROOM) 3 75 8,892 SF (REMAINDER) 178 TOTAL 260 12,656 SF (TOTAL) 840 SF (RESIDENTIAL) 11,816 SF (REMAINDER) TOTAL 5 236 241 TOTAL 4 24 223 251 12,430 SF (TOTAL) 720 SF (RESIDENTIAL) 560 SF (CHAPEL) 11,150 SF (REMAINDER) 3RD = 11,387 228 4TH= 11,387 228 5TH= 11,387 228 6TH= 11,387 228 FEC 2 FINISH REQUIREMENTS FIRST FLOOR LIFE SAFETY PLAN - ISSUE R:\PLANT\DESIGN PROJECTS\KUHLMAN HALL\KUHLMAN 2015 PHASE III - REVISED\SHEETS\LS100 LIFE SAFETY PLANS.DWG - FEC DATE ACTUAL BUILDING FOOTPRINT OF HUSMAN HALL BUILDING FOOTPRINT OF KUHLMAN HALL ADDITION TOTAL ALLOWABLE AREA = UL UNLIMITED REVISION FIRE RATING OF EXISTING FLOORS: FIRE RATING OF EXISTING PARTITIONS: XAVIER UNIVERSITY 3824 LEDGEWOOD DRIVE CINCINNATI, OHIO 45207 KUHLMAN HALL RENOVATION PHASE III ALL RATED WALLS AND SHAFTS ARE INDICATED ON PLANS. THESE WALLS ARE NOT BEING UPGRADED. ANY NEW WORK DONE TO THESE PARTITIONS SHALL BE RATED ACCORDINGLY. - NOTE: 1/16" = 1'-0" INTERIOR WALL AND CEILING EXIT ENCLOSURES & EXIT PASSAGEWAYS CORRIDORS ROOMS & ENCLOSED SPACES CLASS B CLASS B CLASS C OFFICE OF PHYSICAL PLANT XAVIER UNIVERSITY 3800 VICTORY PARKWAY CINCINNATI, OH 45207 513-745-2037 EXISTING CHAPEL OCCUPANT LOAD= 24 SEATS RACHEL E. BIESIK, LICENSE #11710 EXPIRATION DATE: 12/31/2015 DRAWN BY: CHECKED BY: JKF REB FEC FE ELEVATOR LOBBY FEC FEC LIFE SAFETY PLANS 4/17/2015 10:48 AM PROJECT NUMBER 911723 3 SECOND FLOOR LIFE SAFETY PLAN 1/16" = 1'-0" DATE APRIL 17, 2015 SHEET NO. LS100 1 HR FIRE-RATED PARTITION 2 HR FIRE RATED BARRIER 2 HR FIRE-RATED VERTICAL SHAFTS EXIT SIGN (EXISTING) FE - FIRE EXTINGUISHER FEC - FIRE EXTINGUISHER CABINET (EXISTING) (EXISTING) FEC FEC EXISTING CONDITIONS ELEVATOR LOBBY FEC USE GROUP = R-2 CONSTRUCTION TYPE = 1B (NON-COMBUSTIBLE.) STORIES = 7 1 FIRE PROTECTION SYSTEMS AUTOMATIC SPRINKLER SYSTEM: BUILDING IS PARTIALLY SPRINKLERED, NO CHANGE AUTOMATIC FIRE ALARM SYSTEM: INSTALLED THROUGHOUT. THIRD FLOOR LIFE SAFETY PLAN 1/16" = 1'-0" SLABS. 2 HOURS MINIMUM. SEE LIFE SAFETY DRAWINGS. FEC GROUND = MINUS MINUS MINUS FE ELEVATOR LOBBY FEC 1ST = MINUS 2ND = MINUS MINUS FOURTH FLOOR LIFE SAFETY PLAN OCCUPANT LOAD 11,969 SF (TOTAL) 1,040 SF (ACCESSORY STORAGE) 4 914 SF (MECH. EQUIP. ROOM) 3 75 8,892 SF (REMAINDER) 178 TOTAL 260 12,656 SF (TOTAL) 840 SF (RESIDENTIAL) 11,816 SF (REMAINDER) TOTAL 5 236 241 TOTAL 4 24 223 251 12,430 SF (TOTAL) 720 SF (RESIDENTIAL) 560 SF (CHAPEL) 11,150 SF (REMAINDER) 1/16" = 1'-0" 3RD = 11,387 228 4TH= 11,387 228 5TH= 11,387 228 6TH= 11,387 228 FINISH REQUIREMENTS - ISSUE R:\PLANT\DESIGN PROJECTS\KUHLMAN HALL\KUHLMAN 2015 PHASE III - REVISED\SHEETS\LS101 LIFE SAFETY PLANS.DWG - 2 13, 150 SF 12, 656 SF 25, 807 SF DATE ACTUAL BUILDING FOOTPRINT OF HUSMAN HALL BUILDING FOOTPRINT OF KUHLMAN HALL ADDITION TOTAL ALLOWABLE AREA = UL UNLIMITED REVISION FIRE RATING OF EXISTING FLOORS: FIRE RATING OF EXISTING PARTITIONS: XAVIER UNIVERSITY 3824 LEDGEWOOD DRIVE CINCINNATI, OHIO 45207 KUHLMAN HALL RENOVATION PHASE III ALL RATED WALLS AND SHAFTS ARE INDICATED ON PLANS. THESE WALLS ARE NOT BEING UPGRADED. ANY NEW WORK DONE TO THESE PARTITIONS SHALL BE RATED ACCORDINGLY. - NOTE: INTERIOR WALL AND CEILING FEC EXIT ENCLOSURES & EXIT PASSAGEWAYS CORRIDORS ROOMS & ENCLOSED SPACES FEC ELEVATOR LOBBY FEC OFFICE OF PHYSICAL PLANT XAVIER UNIVERSITY 3800 VICTORY PARKWAY CINCINNATI, OH 45207 513-745-2037 S 3 CLASS B CLASS B CLASS C FIFTH FLOOR LIFE SAFETY PLAN 1/16" = 1'-0" FE S RACHEL E. BIESIK, LICENSE #11710 EXPIRATION DATE: 12/31/2015 DRAWN BY: CHECKED BY: JKF REB FEC FEC ELEVATOR LOBBY FEC 5 PENTHOUSE LIFE SAFETY PLAN 1/16" = 1'-0" LIFE SAFETY PLANS 4/17/2015 10:48 AM PROJECT NUMBER 911723 4 SIXTH FLOOR LIFE SAFETY PLAN 1/16" = 1'-0" DATE APRIL 17, 2015 SHEET NO. LS101 3 /16" WIDE GROUT JOINT TYPICAL NEW PORCELAIN TILE. 5/16" THICK W/ 3/16" SETTING BED A. NEW WATERPROOF MEMBRANE MECHANICAL AND ELECTRICAL FIXTURES SHOWN ON ARCHITECTURAL DRAWINGS FOR REFERENCE ONLY. REFER TO MECHANICAL AND ELECTRICAL DRAWINGS FOR NEW AND EXISTING FIXTURE LOCATIONS AND QUANTITIES. 3 4" 1 2" NEW 1/4" UNDERLAYMENT CEMENT BOARD. MATCH EXISTING WOOD UNDERLAYMENT TO REMAIN - IF SOLID. EXISTING STEEL CAB FLOOR NEW INTEGRAL CONCEALED ST ST STUD NEW ST ST NUT W/ SELF LOCKING WASHER 4 NEW FLOOR PLAN KEYNOTES 1. PROVIDE NEW PORCELAIN TILE ON FLOOR OF EXISTING ELEVATOR CABS. SEE SPECIFICATIONS. PROVIDE SHOP DRAWING AND SAMPLE OF FINISH FOR ACCESS PLATE. SCOPE OF ELEVATOR MODERNIZATION. SEE ELEVATION 2/A100 FOR INFORMATION ABOUT NEW HOISTWAY JAMB SIGNAGE. PROVIDE REQUIRED RATED WALL INFILL PATCH, MATCHING EXISTING WALL CONSTRUCTION WITH PLASTER FINISH, AT EACH NEW ELEVATOR LOBBY HALL STATION (FLOORS G-6) TO INFILL PRIOR INSTALLATIONS OF HALL STATION PANELS. COORDINATE EXTENT AND HEIGHT OF INFILL WITH ELEVATOR MANUFACTURER INSTALLER. REMOVE ALL EXISTING SIGNAGE. PLASTER AND PAINT WHERE SIGNS AND FASTENERS WERE REMOVED, MATCHING EXISTING FINISH AND COLOR. PROVIDE AND INSTALL NEW "IN CASE OF FIRE USE STAIRS SIGN" CENTERED BETWEEN DOORS AS SHOWN ON ELEVATION 7/A100. PROVIDE SUBMITTAL TO ARCHITECT FOR SIGN VERIFICATION. INSTALL DIGITAL PRINT EVACUATION SIGN INSIDE CLEAR ACRYLIC HOLDER AS SHOWN ON ELEVATION 7/A100. NEW 5" DIAMETER x 1/16 " THICK STEEL PLATE 341" 2. 3. EXISTING ACCESS HOLE TO REMAIN NEW ACCESS PLATE SECTION 4. 6"-1'-0" TEXTURED FINISH . PROVIDE SAMPLES. SURFACE @ -1/16 " 5. SATIN FINISH SATIN FINISH SATIN FINISH 1 2" 1" ST ST WALL BASE BY ELEVATOR MFR 234" SILICONE SEALANT 1/2" BACKER ROD PORCELAIN TILE ON SETTING BED XAVIER UNIVERSITY 3824 LEDGEWOOD DRIVE CINCINNATI, OHIO 45207 NEW ST ST RECEIVER TRIM. FASTEN TO EXISTING PLYWOOD W/ COUNTERSUNK FLATHEAD ST ST SCREWS NEW FLOOR PLAN GENERAL NOTES KUHLMAN HALL RENOVATION PHASE III EXISTING ACCESS PLATE AND RECEIVER TRIM TO REMAIN. DRILL HOLE AS NEEDED. NEW REMOVABLE CAST STAINLESS STEEL ACCESS PLATE CEMENT BOARD 7" NEW ST ST ACCES PLATE PERIMETER MOVEMENT JOINT DETAIL / NEW TILE FLOOR FINISH OF ELEVATOR CAB 5 NEW ACCESS PLATE / PLAN VIEW 6 6"-1'-0" PERIMETER MOVEMENT JOINT - DATE 9" NEW ST ST RECEIVER TRIM 4'-1" 6"-1'-0" 6'-7" REMOVE EXISTING ADJACENT IN 3 16" MORTAR BED AND PROVIDE SCHLUTER SCHIENE E 125EB EDGE FLUSH W/ NEW 1 REVISION THRESHOLD AND PARTIAL TILES. PATCH LOBBY FLOOR "IN CASE OF FIRE USE STAIRS" SIGN, 6" X 7" DOORS ON ALL (7) LEVELS. 4'-1" NEW PORCELAIN TILE, CEMENT BOARD, AND WATERPROOF MEMBRANE. SEE SPEC AND DETAILS THIS SHEET. EQ - ISSUE 3'-8" NEW ACCESS PANEL. SEE DTL 5/A100 DIGITAL PRINT EVACUATION SIGN INSIDE CLEAR ACRYLIC PLAN HOLDER, 11"X17" 5'-2" 6'-0" 6'-7" PROVIDE 1/2" WIDE MOVEMENT JOINT AT PERIMETER . SEE DTL 6/A100 NEW SCHLUTER SCHIENE E125EB EQ NEW HOISTWAY SIGNAGE ON INSIDE OF ELEVATOR DOOR JAMB (BY OTHERS) MATCH 3 TYPICAL ELEVATOR FLOOR FINISH PLAN 1/4"=1'-0" 7 LOBBY SIGNAGE 1 1/2" = 1'-0" HOISTWAY SIGNAGE GENERAL NOTE A. B. 5'-0" R:\PLANT\DESIGN PROJECTS\KUHLMAN HALL\KUHLMAN 2015 PHASE III - REVISED\SHEETS\A100 NEW GROUND FLOOR.DWG 1 C. D. 1 FLOOR DESIGNATION SHALL BE ON BOTH JAMBS OF THE ELEVATOR HOISTWAY ENTRANCE. FLOOR DESIGNATIONS SHALL BE PROVIDED IN BOTH TACTILE CHARACTERS AND BRAILLE. TACTILE CHARACTERS SHALL BE 2 INCHES (51 MM) HIGH MINIMUM. A TACTILE STAR SHALL BE PROVIDED ON BOTH JAMBS AT THE MAIN ENTRY LEVEL (GROUND LEVEL). 3 OFFICE OF PHYSICAL PLANT XAVIER UNIVERSITY 3800 VICTORY PARKWAY CINCINNATI, OH 45207 513-745-2037 RACHEL E. BIESIK, LICENSE #11710 EXPIRATION DATE: 12/31/2015 4 5 DRAWN BY: CHECKED BY: JKF REB 3 2 2 1 3 HOISTWAY SIGNAGE 3/4" = 1'-0" NEW GROUND FLOOR A100 4/17/2015 10:48 AM PROJECT NUMBER 911723 DATE APRIL 17, 2015 1 GROUND FLOOR PLAN SHEET NO. 1/8" = 1'-0" A100 NEW FLOOR PLAN GENERAL NOTES C. D. MATCH E. 2 7 NEW FLOOR PLAN KEYNOTES 6 1. 2. 7 5 3. 4. 5. 6. 3 7. 7 4 NEW ENLARGED ELEVATOR MACHINE ROOM PLAN NEW PAINTING SCHEDULE - - REVISION ISSUE MATCH R:\PLANT\DESIGN PROJECTS\KUHLMAN HALL\KUHLMAN 2015 PHASE III - REVISED\SHEETS\A107 ROOF AND ELEVATOR MACHINE ROOM PLAN.DWG P-1 MATCH EXISTING ELEVATOR MACHINE ROOM EXTERIOR DOOR FRAME (EXTERIOR DOOR AND LOUVERS) - 1/4" = 1'-0" DATE 2 SCOPE OF ELEVATOR MODERNIZATION. REMOVE THRU-WALL A/C UNIT WOOD FRAMING AND PANEL, METAL THRU-WALL FRAME, AND ANY OTHER INFILL PANELS. REMOVE PRIOR INFILL BRICK (12 BRICKS). PATCH OPENING (NOM. 1'-4"H X 3'-8"W) WITH NOM. 4" CMU INSIDE AND NOM. 4" FACE BRICK ON THE EXTERIOR. SEE GENERAL NOTE E. REMOVE METAL THRU-WALL FRAME, BLANK-OFF PANELS AND EXTERIOR LOUVER. PATCH OPENING (NOM. 1'-4"H X 3'-8"W) WITH NOM. 4" CMU INSIDE AND NOM. 4" FACE BRICK ON THE EXTERIOR. SEE GENERAL NOTE E. PATCH OPENING OF DEMO'D THRU-WALL EXHAUST UNIT (NOM. 1'-4"H X 1'-4"W) WITH NOM. 4" CMU INSIDE AND NOM. 4" FACE BRICK ON THE EXTERIOR. SEE GENERAL NOTE E. PREP AND PAINT EXTERIOR LOUVERS COLOR P-1. PREP AND PAINT THE OUTSIDE ONLY OF THE EXTERIOR DOOR COLOR P-1. PACK ALL GAPS/HOLES AT FLOOR PENETRATIONS WITH MINERAL WOOL. SEAL TOP OF MINERAL WOOL WITH FIRE-RATED CAULK PER FIRESTOPPING MANUFACTURER'S INSTRUCTIONS. REFER TO UL DESIGN SYSTEM NO. C-AJ-1226. SEE FIRESTOPPING SPECIFICATIONS. XAVIER UNIVERSITY 3824 LEDGEWOOD DRIVE CINCINNATI, OHIO 45207 B. MECHANICAL AND ELECTRICAL FIXTURES SHOWN ON ARCHITECTURAL DRAWINGS FOR REFERENCE ONLY. REFER TO MECHANICAL AND ELECTRICAL DRAWINGS FOR NEW AND EXISTING FIXTURE LOCATIONS AND QUANTITIES. COORDINATE ALL WORK WITH MECHANICAL AND ELECTRICAL DRAWINGS. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR SPECIFIC INFORMATION ON PRODUCTS USED. IF CONTRACTOR SHOULD DISCOVER ANY UNFORESEEN PROBLEMS DURING THE REMOVAL OF ANY EXISTING CONSTRUCTION OR THE CONSTRUCTION OF ANY NEW WORK, THE ARCHITECT SHOULD BE NOTIFIED IMMEDIATELY AND THAT PARTICULAR WORK SHOULD BE DISCONTINUED UNTIL NECESSARY REVISIONS CAN BE DECIDED UPON. ALL CMU INFILL TO BE NOM. 4X8X16 IN SIZE. ALL FACE BRICK INFILL TO NOM. 4X2-12X8. FILL COLLAR JOINT WITH GROUT. SEE SPECIFICATIONS. KUHLMAN HALL RENOVATION PHASE III A. OFFICE OF PHYSICAL PLANT XAVIER UNIVERSITY 3800 VICTORY PARKWAY CINCINNATI, OH 45207 513-745-2037 RACHEL E. BIESIK, LICENSE #11710 EXPIRATION DATE: 12/31/2015 DRAWN BY: CHECKED BY: JKF REB ROOF AND ELEVATOR MACHINE ROOM PLAN 1 2 A107 4/17/2015 10:48 AM PROJECT NUMBER 911723 1 NEW ROOF AND ELEVATOR MACHINE ROOM PLAN 1/8" = 1'-0" DATE APRIL 17, 2015 SHEET NO. A107