KUHLMAN HALL RENOVATION PHASE III XAVIER UNIVERSITY

advertisement
ALD
XAVIER UNIVERSITY
REAG
HIGHW
AGAN
LD RE
A
N
O
R
126
AN H
126
IGHW
A
126
Y
42
75
27
71
127
22
NOR
WO
OD
LA
TER
562
74
AL
50
75
22
27
71
42
50
71
50
27
50
75
CINCINNATI
471
71
127
27
75
42
27
CINCINNATI, OH
XAVIER UNIVERSITY
3824 LEDGEWOOD DRIVE
CINCINNATI, OHIO 45207
KUHLMAN HALL RENOVATION
PHASE III
22
AY
RON
126
50
SITE LOCATION
DATE
XAVIER UNIVERSITY
3824 LEDGEWOOD DRIVE
CINCINNATI, OHIO 45207
71
42
127
-
KUHLMAN HALL
RENOVATION
PHASE III
75
27
PROJECT SUMMARY
REVISION
KUHLMAN HALL IS A 7-STORY BRICK, CMU, AND CONCRETE STRUCTURE
CONSTRUCTED IN 1966. KUHLMAN HALL IS CONNECTED TO HUSMAN
HALL, BUILT 1964, AND SEPARATED BY A 12'-0" WIDE BREEZEWAY.
HUSMAN HALL MECHANICAL AND ELECTRICAL SYSTEMS ARE FED
THROUGH KUHLMAN HALL.
-
ISSUE
R:\PLANT\DESIGN PROJECTS\KUHLMAN HALL\KUHLMAN 2015 PHASE III - REVISED\SHEETS\G001 COVER SHEET.DWG
-
SCOPE OF THIS PROJECT:
1. WORK ASSOCIATED WITH ELEVATOR MODERNIZATION
XAVIER UNIVERSITY CAMPUS
SHEET INDEX
SHEET NO SHEET TITLE
OFFICE OF PHYSICAL PLANT
XAVIER UNIVERSITY
3800 VICTORY PARKWAY
CINCINNATI, OH 45207
513-745-2037
G001
COVER SHEET
LS100
LIFE SAFETY PLANS
LS101
LIFE SAFETY PLANS
A100
NEW GROUND FLOOR
A107
ROOF AND ELEVATOR MACHINE ROOM PLAN
HD107
H.V.A.C. - DEMOLITION - ROOF
HV107
H.V.A.C. - NEW DUCTWORK - ROOF
HV500
H.V.A.C. - COMCHECK
E000
ELECTRIC LEGEND
ED100
ELECTRIC DEMOLITION - GROUND FLOOR
ED107
ELECTRIC DEMOLITION - ROOF
E100
ELECTRIC - GROUND FLOOR
RACHEL E. BIESIK, LICENSE #11710
EXPIRATION DATE: 12/31/2015
E107
ELECTRIC - ROOF
DRAWN BY:
CHECKED BY:
E201
ELECTRICAL SCHEDULES
JKF
REB
E300
ELECTRICAL SINGLE-LINE DIAGRAM
COVER
SHEET
4/17/2015 10:48 AM
PROJECT NUMBER
911723
DATE
APRIL 17, 2015
SHEET NO.
G001
1 HR FIRE-RATED PARTITION
2 HR FIRE RATED BARRIER
2 HR FIRE-RATED
VERTICAL SHAFTS
INCIDENTAL
OCCUPANCY AREA
IS SPRINKLERED
FE
EXIT SIGN
(EXISTING)
FE - FIRE EXTINGUISHER
FEC - FIRE EXTINGUISHER CABINET
(EXISTING)
(EXISTING)
FEC
ELEVATOR
LOBBY PART OF
EXIT
ACCESS
INCIDENTAL
OCCUPANCY AREA
IS SPRINKLERED
FEC
FEC
EXISTING CONDITIONS
USE GROUP = R-2
CONSTRUCTION TYPE = 1B (NON-COMBUSTIBLE.)
1
GROUND FLOOR LIFE SAFETY PLAN
STORIES = 7
1/16" = 1'-0"
FIRE PROTECTION SYSTEMS
AUTOMATIC SPRINKLER SYSTEM: BUILDING IS PARTIALLY
SPRINKLERED, NO CHANGE
AUTOMATIC FIRE ALARM SYSTEM: INSTALLED THROUGHOUT.
ACCESSIBLE ENTRANCE
(1 OF 2 MAIN ENTRANCES)
SLABS.
2 HOURS MINIMUM.
SEE LIFE SAFETY
DRAWINGS.
GROUND =
MINUS
MINUS
MINUS
FEC
1ST =
MINUS
2ND =
MINUS
MINUS
FEC
ELEVATOR
LOBBY
13, 150 SF
12, 656 SF
25, 807 SF
OCCUPANT LOAD
11,969 SF (TOTAL)
1,040 SF (ACCESSORY STORAGE)
4
914 SF (MECH. EQUIP. ROOM)
3
75
8,892 SF (REMAINDER)
178
TOTAL
260
12,656 SF (TOTAL)
840 SF (RESIDENTIAL)
11,816 SF (REMAINDER)
TOTAL
5
236
241
TOTAL
4
24
223
251
12,430 SF (TOTAL)
720 SF (RESIDENTIAL)
560 SF (CHAPEL)
11,150 SF (REMAINDER)
3RD =
11,387
228
4TH=
11,387
228
5TH=
11,387
228
6TH=
11,387
228
FEC
2
FINISH REQUIREMENTS
FIRST FLOOR LIFE SAFETY PLAN
-
ISSUE
R:\PLANT\DESIGN PROJECTS\KUHLMAN HALL\KUHLMAN 2015 PHASE III - REVISED\SHEETS\LS100 LIFE SAFETY PLANS.DWG
-
FEC
DATE
ACTUAL BUILDING FOOTPRINT OF HUSMAN HALL
BUILDING FOOTPRINT OF KUHLMAN HALL ADDITION
TOTAL
ALLOWABLE AREA = UL UNLIMITED
REVISION
FIRE RATING OF EXISTING FLOORS:
FIRE RATING OF EXISTING PARTITIONS:
XAVIER UNIVERSITY
3824 LEDGEWOOD DRIVE
CINCINNATI, OHIO 45207
KUHLMAN HALL RENOVATION
PHASE III
ALL RATED WALLS AND SHAFTS ARE INDICATED ON
PLANS. THESE WALLS ARE NOT BEING UPGRADED.
ANY NEW WORK DONE TO THESE PARTITIONS SHALL
BE RATED ACCORDINGLY.
-
NOTE:
1/16" = 1'-0"
INTERIOR WALL AND CEILING
EXIT ENCLOSURES & EXIT PASSAGEWAYS
CORRIDORS
ROOMS & ENCLOSED SPACES
CLASS B
CLASS B
CLASS C
OFFICE OF PHYSICAL PLANT
XAVIER UNIVERSITY
3800 VICTORY PARKWAY
CINCINNATI, OH 45207
513-745-2037
EXISTING
CHAPEL
OCCUPANT
LOAD=
24 SEATS
RACHEL E. BIESIK, LICENSE #11710
EXPIRATION DATE: 12/31/2015
DRAWN BY:
CHECKED BY:
JKF
REB
FEC
FE
ELEVATOR
LOBBY
FEC
FEC
LIFE
SAFETY
PLANS
4/17/2015 10:48 AM
PROJECT NUMBER
911723
3
SECOND FLOOR LIFE SAFETY PLAN
1/16" = 1'-0"
DATE
APRIL 17, 2015
SHEET NO.
LS100
1 HR FIRE-RATED PARTITION
2 HR FIRE RATED BARRIER
2 HR FIRE-RATED
VERTICAL SHAFTS
EXIT SIGN
(EXISTING)
FE - FIRE EXTINGUISHER
FEC - FIRE EXTINGUISHER CABINET
(EXISTING)
(EXISTING)
FEC
FEC
EXISTING CONDITIONS
ELEVATOR
LOBBY
FEC
USE GROUP = R-2
CONSTRUCTION TYPE = 1B (NON-COMBUSTIBLE.)
STORIES = 7
1
FIRE PROTECTION SYSTEMS
AUTOMATIC SPRINKLER SYSTEM: BUILDING IS PARTIALLY
SPRINKLERED, NO CHANGE
AUTOMATIC FIRE ALARM SYSTEM: INSTALLED THROUGHOUT.
THIRD FLOOR LIFE SAFETY PLAN
1/16" = 1'-0"
SLABS.
2 HOURS MINIMUM.
SEE LIFE SAFETY
DRAWINGS.
FEC
GROUND =
MINUS
MINUS
MINUS
FE
ELEVATOR
LOBBY
FEC
1ST =
MINUS
2ND =
MINUS
MINUS
FOURTH FLOOR LIFE SAFETY PLAN
OCCUPANT LOAD
11,969 SF (TOTAL)
1,040 SF (ACCESSORY STORAGE)
4
914 SF (MECH. EQUIP. ROOM)
3
75
8,892 SF (REMAINDER)
178
TOTAL
260
12,656 SF (TOTAL)
840 SF (RESIDENTIAL)
11,816 SF (REMAINDER)
TOTAL
5
236
241
TOTAL
4
24
223
251
12,430 SF (TOTAL)
720 SF (RESIDENTIAL)
560 SF (CHAPEL)
11,150 SF (REMAINDER)
1/16" = 1'-0"
3RD =
11,387
228
4TH=
11,387
228
5TH=
11,387
228
6TH=
11,387
228
FINISH REQUIREMENTS
-
ISSUE
R:\PLANT\DESIGN PROJECTS\KUHLMAN HALL\KUHLMAN 2015 PHASE III - REVISED\SHEETS\LS101 LIFE SAFETY PLANS.DWG
-
2
13, 150 SF
12, 656 SF
25, 807 SF
DATE
ACTUAL BUILDING FOOTPRINT OF HUSMAN HALL
BUILDING FOOTPRINT OF KUHLMAN HALL ADDITION
TOTAL
ALLOWABLE AREA = UL UNLIMITED
REVISION
FIRE RATING OF EXISTING FLOORS:
FIRE RATING OF EXISTING PARTITIONS:
XAVIER UNIVERSITY
3824 LEDGEWOOD DRIVE
CINCINNATI, OHIO 45207
KUHLMAN HALL RENOVATION
PHASE III
ALL RATED WALLS AND SHAFTS ARE INDICATED ON
PLANS. THESE WALLS ARE NOT BEING UPGRADED.
ANY NEW WORK DONE TO THESE PARTITIONS SHALL
BE RATED ACCORDINGLY.
-
NOTE:
INTERIOR WALL AND CEILING
FEC
EXIT ENCLOSURES & EXIT PASSAGEWAYS
CORRIDORS
ROOMS & ENCLOSED SPACES
FEC
ELEVATOR
LOBBY
FEC
OFFICE OF PHYSICAL PLANT
XAVIER UNIVERSITY
3800 VICTORY PARKWAY
CINCINNATI, OH 45207
513-745-2037
S
3
CLASS B
CLASS B
CLASS C
FIFTH FLOOR LIFE SAFETY PLAN
1/16" = 1'-0"
FE
S
RACHEL E. BIESIK, LICENSE #11710
EXPIRATION DATE: 12/31/2015
DRAWN BY:
CHECKED BY:
JKF
REB
FEC
FEC
ELEVATOR
LOBBY
FEC
5
PENTHOUSE LIFE SAFETY PLAN
1/16" = 1'-0"
LIFE
SAFETY
PLANS
4/17/2015 10:48 AM
PROJECT NUMBER
911723
4
SIXTH FLOOR LIFE SAFETY PLAN
1/16" = 1'-0"
DATE
APRIL 17, 2015
SHEET NO.
LS101
3 /16" WIDE GROUT
JOINT TYPICAL
NEW PORCELAIN TILE.
5/16" THICK W/ 3/16"
SETTING BED
A.
NEW WATERPROOF
MEMBRANE
MECHANICAL AND ELECTRICAL FIXTURES SHOWN ON
ARCHITECTURAL DRAWINGS FOR REFERENCE ONLY.
REFER TO MECHANICAL AND ELECTRICAL DRAWINGS
FOR NEW AND EXISTING FIXTURE LOCATIONS AND
QUANTITIES.
3
4"
1
2"
NEW 1/4"
UNDERLAYMENT
CEMENT BOARD.
MATCH
EXISTING WOOD
UNDERLAYMENT TO
REMAIN - IF SOLID.
EXISTING STEEL CAB
FLOOR
NEW INTEGRAL CONCEALED
ST ST STUD
NEW ST ST NUT W/ SELF LOCKING
WASHER
4
NEW FLOOR PLAN KEYNOTES
1.
PROVIDE NEW PORCELAIN TILE ON FLOOR OF EXISTING
ELEVATOR CABS. SEE SPECIFICATIONS. PROVIDE SHOP
DRAWING AND SAMPLE OF FINISH FOR ACCESS PLATE.
SCOPE OF ELEVATOR MODERNIZATION.
SEE ELEVATION 2/A100 FOR INFORMATION ABOUT NEW
HOISTWAY JAMB SIGNAGE.
PROVIDE REQUIRED RATED WALL INFILL PATCH,
MATCHING EXISTING WALL CONSTRUCTION WITH
PLASTER FINISH, AT EACH NEW ELEVATOR LOBBY HALL
STATION (FLOORS G-6) TO INFILL PRIOR INSTALLATIONS
OF HALL STATION PANELS. COORDINATE EXTENT AND
HEIGHT OF INFILL WITH ELEVATOR MANUFACTURER
INSTALLER.
REMOVE ALL EXISTING SIGNAGE. PLASTER AND PAINT
WHERE SIGNS AND FASTENERS WERE REMOVED,
MATCHING EXISTING FINISH AND COLOR. PROVIDE AND
INSTALL NEW "IN CASE OF FIRE USE STAIRS SIGN"
CENTERED BETWEEN DOORS AS SHOWN ON ELEVATION
7/A100. PROVIDE SUBMITTAL TO ARCHITECT FOR SIGN
VERIFICATION. INSTALL DIGITAL PRINT EVACUATION
SIGN INSIDE CLEAR ACRYLIC HOLDER AS SHOWN ON
ELEVATION 7/A100.
NEW 5" DIAMETER x 1/16
" THICK STEEL PLATE
341"
2.
3.
EXISTING ACCESS HOLE TO
REMAIN
NEW ACCESS PLATE SECTION
4.
6"-1'-0"
TEXTURED FINISH . PROVIDE
SAMPLES. SURFACE @ -1/16 "
5.
SATIN FINISH
SATIN FINISH
SATIN FINISH
1
2"
1"
ST ST WALL BASE
BY ELEVATOR MFR
234"
SILICONE SEALANT
1/2" BACKER ROD
PORCELAIN TILE
ON SETTING BED
XAVIER UNIVERSITY
3824 LEDGEWOOD DRIVE
CINCINNATI, OHIO 45207
NEW ST ST RECEIVER
TRIM. FASTEN TO
EXISTING PLYWOOD W/
COUNTERSUNK
FLATHEAD ST ST
SCREWS
NEW FLOOR PLAN GENERAL NOTES
KUHLMAN HALL RENOVATION
PHASE III
EXISTING ACCESS
PLATE AND RECEIVER
TRIM TO REMAIN.
DRILL HOLE AS
NEEDED.
NEW REMOVABLE
CAST STAINLESS STEEL
ACCESS PLATE
CEMENT BOARD
7"
NEW ST ST ACCES PLATE
PERIMETER MOVEMENT JOINT DETAIL /
NEW TILE FLOOR FINISH OF ELEVATOR CAB
5
NEW ACCESS PLATE / PLAN VIEW
6
6"-1'-0"
PERIMETER MOVEMENT JOINT
-
DATE
9"
NEW ST ST RECEIVER TRIM
4'-1"
6"-1'-0"
6'-7"
REMOVE EXISTING ADJACENT
IN 3 16" MORTAR BED AND
PROVIDE SCHLUTER SCHIENE
E 125EB EDGE FLUSH W/ NEW
1
REVISION
THRESHOLD AND PARTIAL
TILES. PATCH LOBBY FLOOR
"IN CASE OF
FIRE USE
STAIRS" SIGN,
6" X 7"
DOORS ON ALL (7) LEVELS.
4'-1"
NEW PORCELAIN TILE, CEMENT
BOARD, AND WATERPROOF
MEMBRANE. SEE SPEC AND
DETAILS THIS SHEET.
EQ
-
ISSUE
3'-8"
NEW ACCESS PANEL. SEE
DTL 5/A100
DIGITAL PRINT
EVACUATION
SIGN INSIDE
CLEAR ACRYLIC
PLAN HOLDER,
11"X17"
5'-2"
6'-0"
6'-7"
PROVIDE 1/2" WIDE
MOVEMENT JOINT AT
PERIMETER . SEE DTL 6/A100
NEW SCHLUTER
SCHIENE E125EB
EQ
NEW HOISTWAY SIGNAGE ON INSIDE OF
ELEVATOR DOOR JAMB (BY OTHERS)
MATCH
3
TYPICAL ELEVATOR FLOOR FINISH PLAN
1/4"=1'-0"
7
LOBBY SIGNAGE
1
1/2" = 1'-0"
HOISTWAY SIGNAGE GENERAL NOTE
A.
B.
5'-0"
R:\PLANT\DESIGN PROJECTS\KUHLMAN HALL\KUHLMAN 2015 PHASE III - REVISED\SHEETS\A100 NEW GROUND FLOOR.DWG
1
C.
D.
1
FLOOR DESIGNATION SHALL BE
ON BOTH JAMBS OF THE
ELEVATOR HOISTWAY ENTRANCE.
FLOOR DESIGNATIONS SHALL BE
PROVIDED IN BOTH TACTILE
CHARACTERS AND BRAILLE.
TACTILE CHARACTERS SHALL BE 2
INCHES (51 MM) HIGH MINIMUM.
A TACTILE STAR SHALL BE
PROVIDED ON BOTH JAMBS AT
THE MAIN ENTRY LEVEL (GROUND
LEVEL).
3
OFFICE OF PHYSICAL PLANT
XAVIER UNIVERSITY
3800 VICTORY PARKWAY
CINCINNATI, OH 45207
513-745-2037
RACHEL E. BIESIK, LICENSE #11710
EXPIRATION DATE: 12/31/2015
4
5
DRAWN BY:
CHECKED BY:
JKF
REB
3
2
2
1
3
HOISTWAY SIGNAGE
3/4" = 1'-0"
NEW
GROUND
FLOOR
A100
4/17/2015 10:48 AM
PROJECT NUMBER
911723
DATE
APRIL 17, 2015
1
GROUND FLOOR PLAN
SHEET NO.
1/8" = 1'-0"
A100
NEW FLOOR PLAN GENERAL NOTES
C.
D.
MATCH
E.
2
7
NEW FLOOR PLAN KEYNOTES
6
1.
2.
7
5
3.
4.
5.
6.
3
7.
7
4
NEW ENLARGED ELEVATOR MACHINE ROOM PLAN
NEW PAINTING SCHEDULE
-
-
REVISION
ISSUE
MATCH
R:\PLANT\DESIGN PROJECTS\KUHLMAN HALL\KUHLMAN 2015 PHASE III - REVISED\SHEETS\A107 ROOF AND ELEVATOR MACHINE ROOM PLAN.DWG
P-1 MATCH EXISTING ELEVATOR MACHINE ROOM EXTERIOR
DOOR FRAME
(EXTERIOR DOOR AND LOUVERS)
-
1/4" = 1'-0"
DATE
2
SCOPE OF ELEVATOR MODERNIZATION.
REMOVE THRU-WALL A/C UNIT WOOD FRAMING AND
PANEL, METAL THRU-WALL FRAME, AND ANY OTHER
INFILL PANELS. REMOVE PRIOR INFILL BRICK (12
BRICKS). PATCH OPENING (NOM. 1'-4"H X 3'-8"W) WITH
NOM. 4" CMU INSIDE AND NOM. 4" FACE BRICK ON THE
EXTERIOR. SEE GENERAL NOTE E.
REMOVE METAL THRU-WALL FRAME, BLANK-OFF PANELS
AND EXTERIOR LOUVER. PATCH OPENING (NOM. 1'-4"H X
3'-8"W) WITH NOM. 4" CMU INSIDE AND NOM. 4" FACE
BRICK ON THE EXTERIOR. SEE GENERAL NOTE E.
PATCH OPENING OF DEMO'D THRU-WALL EXHAUST UNIT
(NOM. 1'-4"H X 1'-4"W) WITH NOM. 4" CMU INSIDE AND
NOM. 4" FACE BRICK ON THE EXTERIOR. SEE GENERAL
NOTE E.
PREP AND PAINT EXTERIOR LOUVERS COLOR P-1.
PREP AND PAINT THE OUTSIDE ONLY OF THE EXTERIOR
DOOR COLOR P-1.
PACK ALL GAPS/HOLES AT FLOOR PENETRATIONS WITH
MINERAL WOOL. SEAL TOP OF MINERAL WOOL WITH
FIRE-RATED CAULK PER FIRESTOPPING
MANUFACTURER'S INSTRUCTIONS. REFER TO UL
DESIGN SYSTEM NO. C-AJ-1226. SEE FIRESTOPPING
SPECIFICATIONS.
XAVIER UNIVERSITY
3824 LEDGEWOOD DRIVE
CINCINNATI, OHIO 45207
B.
MECHANICAL AND ELECTRICAL FIXTURES SHOWN ON
ARCHITECTURAL DRAWINGS FOR REFERENCE ONLY.
REFER TO MECHANICAL AND ELECTRICAL DRAWINGS
FOR NEW AND EXISTING FIXTURE LOCATIONS AND
QUANTITIES.
COORDINATE ALL WORK WITH MECHANICAL AND
ELECTRICAL DRAWINGS.
SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR
SPECIFIC INFORMATION ON PRODUCTS USED.
IF CONTRACTOR SHOULD DISCOVER ANY UNFORESEEN
PROBLEMS DURING THE REMOVAL OF ANY EXISTING
CONSTRUCTION OR THE CONSTRUCTION OF ANY NEW
WORK, THE ARCHITECT SHOULD BE NOTIFIED
IMMEDIATELY AND THAT PARTICULAR WORK SHOULD BE
DISCONTINUED UNTIL NECESSARY REVISIONS CAN BE
DECIDED UPON.
ALL CMU INFILL TO BE NOM. 4X8X16 IN SIZE. ALL FACE
BRICK INFILL TO NOM. 4X2-12X8. FILL COLLAR JOINT WITH
GROUT. SEE SPECIFICATIONS.
KUHLMAN HALL RENOVATION
PHASE III
A.
OFFICE OF PHYSICAL PLANT
XAVIER UNIVERSITY
3800 VICTORY PARKWAY
CINCINNATI, OH 45207
513-745-2037
RACHEL E. BIESIK, LICENSE #11710
EXPIRATION DATE: 12/31/2015
DRAWN BY:
CHECKED BY:
JKF
REB
ROOF AND
ELEVATOR
MACHINE
ROOM PLAN
1
2
A107
4/17/2015 10:48 AM
PROJECT NUMBER
911723
1
NEW ROOF AND ELEVATOR MACHINE ROOM PLAN
1/8" = 1'-0"
DATE
APRIL 17, 2015
SHEET NO.
A107