NUMBER SHEET G001 G002 COVER SHEET LEVEL 1 - LIFE SAFETY PLAN A001 AD101 ARCHITECTURAL GENERAL NOTES, SYMBOLS & TYP DETAILS ARCHITECTURAL LEVEL 1 DEMOLITION PLAN A101 A102 A103 A104 A105 A106 A111 LEVEL 1 ARCHITECTURAL FLOOR PLAN LEVEL 1 REFLECTED CEILING PLANS INTERIOR ELEVATIONS ARCHITECTURAL DETAILS ARCHITECTURAL DETAILS THIRD FLOOR SHADE DETAILS DOOR SCHEDULE AND DETAILS I101 I102 INTERIOR FINISH SCHEDULE AND DETAILS FOR REFERENCE - STUDENT LOUNGE FURNITURE LAYOUT 720 E Pete Rose Way #140 Cincinnati, OH 45202 T 513.241.4474 F 513.241.0081 FD101 F101 FIRE PROTECTION- DEMOLITION- FIRST FLOOR FIRE PROTECTION- NEW- FIRST FLOOR thinkchamplin.com MD101 M-101 M-501 MECHANICAL- DEMOLITION- FIRST FLOOR MECHANICAL DUCTWORK- NEW- FIRST FLOOR MECHANICAL DETAILS E-001 E-501 ED101 ELECTRIC LEGEND ELECTRIC- DETAILS ELECTRIC- DEMOLITION- FIRST FLOOR EL101 EL601 ELECTRIC LIGHTING- NEW- FIRST FLOOR ELECTRIC LUMINAIRE SCHEDULE EP101 EP601 EP602 ELECTRIC POWER- NEW- FIRST FLOOR ELECTIRC- SINGLE LINE DIAGRAM ELECTRIC PANEL SCHEDULES DRAWING LIST GALLAGHER STUDENT CENTER PROJECT LOCATION LEVEL 1 Y R O T C VI GALLAGHER CENTER STUDENT CENTER RENOVATION Y W PK XAVIER UNIVERSITY 3800 VICTORY PKWY CINCINNATI, OH 45207 ISSUANCES No. Description Date 1 ISSUED FOR BID/ PERMIT 3/21/2016 DANA AVE . CAMPUS MAP 07009 IS Client Number 81 TE Project Number 5264 I M. J. BATTOCLETTE R EG - E O F OH IT FOR BID/ PERMIT - MARCH 21, 2016 Checked By AT O KPN ST Drawn By EC T GALLAGHER STUDENT CENTER RENOVATION XAVIER UNIVERSITY 3800 VICTORY PARKWAY, CINCINNATI, OH 445207 R E D A RC H M. J. BATTOCLETTE LICENSE #07009 EXPIRATION DATE 12/31/2017 720 E Pete Rose Way Cincinnati, OH 45202 Tel: 513.241.4474 Fax: 513.241.0081 1538 Alexandria Pike, Suite 11 Ft. Thomas, KY 41075 Tel: 859 442 8050 Fax: 859 442 8058 VICINITY MAP G001 3/21/2016 7:50:53 PM COVER SHEET 6 R14 CODE SUMMARY R13 Xavier University - Gallagher Center Student Center Renovation R12 R15 Building Code: All of the following references are to the Ohio Building Code 2011(OBC) Ohio Mechanical Code 2011 (OMC) Project Description: Partial Renovation on the First Level of the existing building. Renovation of the existing campus Bookstore. This area will be divided into approximate half. With one half of the space to remain as the Bookstore with minimal renovation work, finish replacement and finish refurbishment. The remaining half will be renovated as a Student Lounge. 8 Note: No work affecting existing means of egress features. No change to existing fire extinguishers and location. No work at exterior, except minimal electrical work. No work at building structure. No work at existing toilet rooms. No change to existing atrium life safety design or smoke evac system. New work at Atrium corridor wall will match existing design of 1-hour rating achieved through rated walls and deluge sprinklers on either side of borrowed lites meeting building code requirements. 2 8. Building Occupancy Classification: Mixed Use (Original Construction 2002): A-1, A-2, A-3, B, M, S-1, U Construction Type: 2A 8 8. RE R 2H K 5 9. J Automatic Sprinkler System Throughout. Accessibility: Barrier-free design 720 E Pete Rose Way #140 Cincinnati, OH 45202 T 513.241.4474 F 513.241.0081 thinkchamplin.com Building Area 9 RF Automatic Sprinkler System Project Renovation Area 5,770s.f.+/-; Occupancy: A-3 & M (Note: Existing Mercantile Storage is on Ground Level with no change.) Lower Level Area: 29,445s.f. Level One Area: 15,480s.f. Level Two Area: 15,000s.f. Level Three Area: 15,865s.f. R 1H R 2H RC 10 .2 10 6 R1 R18 R1 7 11 1HR .8 10 .2 RB R 2H 4 RA R 2H A A R 1H STUDENT LOUNGE RENOVATION AREA 2,920 S.F. 0'-0" NCE 7 A T S I EL D TRAV R11 R 1H 1HR 1HR B XAVIER UNIVERSITY 3800 VICTORY PKWY CINCINNATI, OH 45207 1HR B 1H R GALLAGHER CENTER STUDENT CENTER RENOVATION -0" 89' C 90'-0" TRAVEL DISTANCE 30'-8" ") 9'-8 =2 R9 3 (1/ R10 RB.3 BOOKSTORE REFURBISHMENT AREA 2,850 S.F. RC.2 ISSUANCES No. Description Date 1 ISSUED FOR BID/ PERMIT 3/21/2016 RD RB R7 R8 1HR C 1HR 2HR 2HR 1HR H D R6 D 1 2 3 G 5 LEGEND 1 HR RATED PARTITION R3 2 3 5 6 EXTERIOR EGRESS POINT Client Number 81 NO WORK THIS AREA Project Number 5264 7 CONTRACTOR TO VERIFY ALL EXISTING RATED WALLS WITHIN SCOPE OF WORK MEET RATED WALL REQUIREMENTS PER RATED WALLS SHOWN IN THE LIFE SAFETY DRAWINGS. EXTEND EXISTING PARTITIONS AS REQUIRED TO UNDERSIDE OF FLOOR/ROOF STRUCTURE ABOVE AND SEAL ALL PENETRATIONS AS REQUIRED AT RATED WALLS. 1 G002 LEVEL 1 - LIFE SAFETY PLAN 3/32" = 1'-0" - I M. J. BATTOCLETTE 07009 IS E 1 Checked By 1HR E O F OH TE R E D A RC H M. J. BATTOCLETTE LICENSE #07009 EXPIRATION DATE 12/31/2017 LEVEL 1 - LIFE SAFETY PLAN G002 3/21/2016 7:51:09 PM R2 KPN AT R EG R4 Drawn By EC T R5 2 HR FIRE RATED BARRIER ASSEMBLY (FIRE DAMPERS REQUIRED) O R1 2HR IT F 7 ST 6 NORTH ARROW AND ANGLE AT CENTERLINE DIAMETER FLOOR LINE PROPERTY LINE POUND OR NUMBER A.B. A.C.M. A/C ACOUS. AC.T. A.D. ADJ. AFF. AGG. AL. ALT. APPROX. ARCH. ASPH. ANCHOR BOLT ASBESTOS CONTAINING MATERIALS ASPHALT CONCRETE PAVING AIR CONDITIONING ACOUSTIC ACOUSTICAL TILE/PANEL AREA DRAIN ADJUSTABLE ABOVE FINISH FLOOR AGGREGATE ALUMINUM ALTERNATE APPROXIMATE ARCHITECT ASPHALT BD. BITUM. BLDG. BLK. BLKG. BM. BOT. BRG. BRK. BRZ. BTWN. B.U.R. BOARD BITUMINOUS BUILDING BLOCK BLOCKING BENCH MARK or BEAM BOTTOM BEARING BRICK BRONZE BETWEEN BUILT-UP ROOFING CAB. CARP. C.B. C.B.B. CNTR. C.O. COL. COMB. COMP. CONC. CONN. CONST. CONT. CONV.O. CTR. C.W. CW. CABINET CARPET CATCH BASIN CEMENTITIOUS BACKER BOARD CEMENT CERAMIC CERAMIC TILE CONTRACTOR FURNISH/ CONTRACTOR INSTALL CONTRACTOR FURNISH/ OWNER INSTALL COAT HOOK CAST IRON CIRCLE CONSTRUCTION JOINT CEILING CEILING JOIST CAULKING CLOSET CLEAR CLOSURE CONCRETE MASONRY UNIT COUNTER CLEAN OUT COLUMN COMBINATION COMPOSITION CONCRETE CONNECTION CONSTRUCTION CONTINUOUS CONVECTION OVEN CENTER COLD WATER CURTAINWALL DET. DF. D.F. DIA. DIAG. DIM. DISP. DIV. DN. D.O. DR. D.S. D.T. D.W. DWG(S). DWR. DETAIL DOUGLAS FIR DRINKING FOUNTAIN DIAMETER DIAGONAL DIMENSION DISPOSAL DIVISION DOWN DOOR OPENING DOOR DOWN SPOUT DRAIN TILE DISHWASHER DRAWING(S) DRAWER (E) EA. E.C. E.E. E.F. E.J. ELEC. ELEV. E.N. EXISTING EACH ELECTRICAL CONTRACTOR EACH END EXHAUST FAN EXPANSION JOINT ELECTRICAL ELEVATION EDGE NAIL A.C.P. LEVEL NAME W/ ELEVATION GRID HEAD CALL OUT HEAD W/ SHEET NUMBER Room name ROOM NAME W/ ROOM NUMBER, AREA & OCCUPANCY 101 150 SF 000 1 SIM BUILDING SECTION NUMBER W/ SHEET NUMBER CEM. CER. CER.T. C.F.C.I. A101 C.F.O.I. SIM 1 C.HK. C.I. CIR. C.J. CLG. CLG.J. CLKG. CLO. CLR. CLS. C.M.U. WALL SECTION NUMBER W/ SHEET NUMBER A101 1 SIM DETAIL SECTION NUMBER W/ SHEET NUMBER A101 DOOR NUMBER 101 WALL TAG 1i WINDOW TAG A 1 View Name 1/8" = 1'-0" A101 VIEW NAME W/ SCALE 1 ADDENDUM TAG C1 10'-0"A.F.F. CEILING TAG W// HEIGHT FIN. FIXT. F.J. F.L. FLASH. FLOUR. FLR. F.N. F.O.B. F.O.C. F.O.F. F.O.M. F.O.S. F.R.T.W. F.S.C. F.S.E.C. FTG. FUT. F.V.C. GA. GALV. G.C. G.B. G.D. G.E. G.I. GL. GLB. GND. GR. G.S.M. GYP.BD. H.B. HC. H.C. HDR. HDWD. HDWE. HGT. H.M. HORIZ. H.P. HR. H.S.S. HTG. H.V.A.C. H.W. JAN. J.H. JST. JT. JANITOR JOIST HANGER JOIST JOINT KIT. KITCHEN LAB. LAM. LAV. L.B. MATERIAL MAXIMUM MACHINE BOLT MEDICINE CABINET MECHANICAL MEDIUM MEMBRANE MECHANICAL, ELECTRICAL, PLUMBING MANUFACTURER MANHOLE MINIMUM MIRROR MISCELLANEOUS MASONRY OPENING MODULAR MOP HOLDER FRAMED MIRROR MOISTURE RESISTANT METAL THRESHOLD MOUNTED METAL S.A.F.F. (N) N. NAT. N.I.C. NO. NOM. NON/COM N.T.S. O/ O.A. OBS. O.C. O.D. O.F. O.F.C.I. OFF. O.F.O.I. O.F.S. O.H.W.S. OPP. P. P.C. P.C.F. P.E.N. PERF. PL. P.LAM. PLAS. P.L.F. PLYWD. P.M.F. PR. PROP. P.S.F. HOSE BIB HANDICAPPED H.V.A.C. CONTRACTOR HEADER HARDWOOD HARDWARE HEIGHT HOLLOW METAL HORIZONTAL HIGH POINT HOUR HOLLOW STRUC. STL. HEATING HEATING, VENTILATION & AIR CONDITIONING HOT WATER INSIDE DIAMETER INSULATION INTERIOR INVERT MAT. MAX. M.B. M.C. MECH. MED. MEMB. M.E.P. MFG. MH. MIN. MIR. MISC. M.O. MOD. MP.H. MR. M.R. M.T. MTD. MTL. GAUGE GALVANIZED GENERAL CONTRACTOR GRAB BAR GARBAGE DISPOSAL GRATE ELEVATION GALVANIZED IRON GLASS GLUE LAMINATED BEAM GROUND GRADE GALVANIZED SHEET METAL GYPSUM BOARD I.D. INSUL. INT. INV. S. S.A.B. P.S.I. P.STA. PTD. P.T.D. PT. P.T.D.F. PTN. P.T.R. P.V.C. NEW NORTH NATURAL NOT IN CONTRACT (NOT PART OF OSA APPROVAL) NUMBER NOMINAL NON-COMBUSTIBLE NOT TO SCALE RAD. R.B. R.C.P. RADIUS RUBBER BASE REFLECTED CEILING PLAN ROOF DRAIN REDWOOD REFERENCE REFRIGERATOR REINFORCING REQUIRED RESILIENT ROOF HATCH ROBE HOOK ROUND HEAD METAL SCREW ROUND HEAD WOOD SCREW ROOM ROUGH OPENING RAIN WATER LEADER R.H.W.S. RM. R.O. R.W.L. SHR. SHT. SHTG. SIM. SL. S.L.D. S.M.D. S.N.D. S.P. SPEC. SQ. SQ. FT. S.S. S.S.D. STA. STD. STL. S. STL. STO. STRUC. SUSP. PAINT PLUMBING CONTRACTOR POUNDS PER CUBIC FOOT PANEL EDGE NAILING PERFORATED PLATE PLASTIC LAMINATE PLASTER POUNDS PER LINEAR FOOT PLYWOOD PRESSED METAL FRAME PAIR PROPERTY POUNDS PER SQUARE FOOT POUNDS PER SQUARE INCH PULL STATION PAINTED PAPER TOWEL DISPENSER POINT PRESSURE TREATED DOUGLAS FIR PARTITION PAPER TOWEL RECEPTACLE POLYVINYL-CHLORIDE QUARRY TILE S.A.S.M. S.BLKG. S.C. S.C.D. S.D. S.DISP. SEAL. SECT. S.E.D. S.N.V. OVER OVERALL OBSCURE ON CENTER OUTSIDE DIAMETER OVERFLOW OWNER FURNISH/ CONTRACTOR INSTALL OFFICE OWNER FURNISH/ OWNER INSTALL OUTSIDE FACE OF STUD OVAL HEAD WOOD SCREW OPPOSITE Q.T. R.D. RDWD. REF. REFR. REINF. REQD. RESIL. R.H. R.HK. R.H.M.S. LABORATORY LAMINATE LAVATORY LAG BOLT S.A.D. T.S. T.V. TYP. TACKBOARD TOP AND BOTTOM TELEPHONE TEMPERED TERRAZZO TONGUE AND GROOVE THICK TOOL JOINT TOE NAIL TOP OF CURB TOP OF PAVEMENT TOP OF PLATE TOP OF SEAT TOP OF WALL TOILET PAPER DISPENSER TRANSOM TOILET SEAT COVER DISPENSER TUBE STEEL TELEVISION TYPICAL UNF. U.N.O. UNFINISHED UNLESS NOTED OTHERWISE UR. U/S URINAL UNDERSIDE V.C.T. VERT. VEST. V.G. V.I.F. V.T. V.T.R. V.W.C. VINYL COMPOSITION TILE VERTICAL VESTIBULE VERTICAL GRAIN VERIFY IN FIELD VINYL TILE VENT TO ROOF VINYL WALL COVERING W. W/ W/IN W.C. WD. WDW. W.F. W.H W/O W.P. W.R. WT. W.W.F. WEST WITH WITHIN WATER CLOSET WOOD WINDOW WATER COOLER WATER HEATER WITHOUT WATER PROOF WATER RESISTANT WEIGHT WELDED WIRE FABRIC YD. YARD T.B. T&BOT. TEL. TEMP. TER. T&G. THK. T.J. T.N. T.O.C. T.O.P. T.O.PL. T.O.S. T.O.W. T.P.D. TRN. T.S.C.D. 1. SOUTH SOUND ATTENUATION BATT SEE ARCHITECTURAL DRAWINGS SELF ADHERED FLEXIBLE FLASHING SELF ADHERED SHEET MEMBRANE SOLID BLOCKING SOLID CORE SEE CIVIL DRAWINGS STORM DRAIN SOAP DISPENSER SEALANT SECTION SEE ELECTRICAL DRAWINGS SHOWER SHEET SHEATHING SIMILAR SLIDING SEE LANDSCAPE DRAWINGS SEE MECHANICAL DRAWINGS SANITARY NAPKIN DISPOSAL SANITARY NAPKIN DISPENSER SOUNDPROOF SPECIFICATION SQUARE SQUARE FOOT (FEET) SANITARY SEWER SEE STRUCTURAL DRAWINGS STATION STANDARD STEEL STAINLESS STEEL STORAGE STRUCTURAL SUSPENDED 2. 3. 4. FASTENER 24" O.C. MAX. SHEAR AND WITHDRAWAL RESISTANCE AS REQUIRED BY SPECIFIC DESIGN CONDITIONS (TYP.) 1-HOUR RATED PARTITION BEYOND 5. 6. 1/2" TYPE S PAN HEAD SCREW AT 12" O.C. (ATTACH BOTH SIDES OF C-H STUD AND J-RUNNER AT TOP AND BOTTOM OF STUD) 7. 8. 9. 10. 11. SEALANT DUCTWORK 12. 13. 14. 1-HOUR RATED SHAFT WALL. 4" STEEL STUDS @ 16" O.C. 15. 16. 1 LAYERS OF 5/8" GYPSUM BOARD 17. 18. 1" GYPSUM LINER PANEL 19. 20. USG STEEL C-H STUD 21. USG STEEL J-RUNNER 22. 1-HOUR RATED SHAFT WALL. 4" STEEL STUDS @ 16" O.C. 23. 24. FASTENER 24" O.C. MAX. SHEAR AND WITHDRAWAL RESISTANCE AS REQUIRED BY SPECIFIC DESIGN CONDITIONS (TYP.) 25. 26. 27. 1-HOUR RATED WALL. SEE PARTITION TYPES. 28. 29. SYMBOLS ABBREVIATIONS 1-HOUR RATED CEILING SECTION 30. TYPE A1 (U.N.O.) ONE LAYER OF 5/8" GYPSUM WALLBOARD ON EACH SIDE OF 3-5/8" 20 GA. METAL STUDS @ 16" O.C. WITH 3" SOUND ATTENUATION BLANKETS IN STUD SPACE. EXTEND STUDS, BOARD, AND BLANKETS FULL HEIGHT TO DECK ABOVE. TYPE A7 ONE LAYER OF 5/8" GYPSUM WALLBOARD ON EACH SIDE OF 3-5/8" 20 GA. METAL STUDS @ 16" O.C. WITH NO SOUND ATTENUATION BLANKETS IN STUD SPACE. EXTEND STUDS AND BOARD TO 6" ABOVE CEILING. BRACE TOP OF WALL AS REQUIRED, BUT NOT LESS THAN 8'-0" O.C. TYPE B7 ONE LAYER OF 5/8" GYPSUM WALLBOARD ON EACH SIDE OF 6" 20 GA. METAL STUDS @ 16" O.C. WITH NO SOUND ATTENUATION BLANKETS IN STUD SPACE. EXTEND STUDS AND BOARD TO 6" ABOVE CEILING. BRACE TOP OF WALL AS REQUIRED, BUT NOT LESS THAN 8'-0" O.C. TYPE C1 ONE LAYER OF 5/8" GYPSUM WALLBOARD ON ROOM SIDE OF 2 1/2" 20 GA. METAL STUDS @ 16" O.C. WITH NO SOUND ATTENUATION BLANKET IN STUD SPACE. EXTEND STUDS AND BOARD FULL HEIGHT TO DECK ABOVE. ATTACH TO STRUCTURE ABOVE W/ VERTICAL SLIP CONNECTIONS. SEE PARTITION NOTES THIS DWG. TYPE WD WOOD ACOUSTICAL PLANK SYSTEM ON FURRING STRIP ATTACHED WITH MOUNTING CLIPS. WC-1 INSTALL PER MANUFACTURER'S INSTRUCTIONS. TYPE GL BACK PAINTED GLASS. PAINT PER FINISH SCHEDULE. SEE DETAILS. TYPE F1 1 HOUR RATED WALL UL# U419 PROVIDE TYPE "X" GYPSUM WALLBOARD FOR 1 HR UL RATING ON EACH SIDE OF 3 5/8" 20 GA. METAL STUDS @ 16" O.C. WITH 3" SOUND ATTENUATION BLANKETS IN STUD SPACE. EXTEND STUDS, BOARD, AND BLANKETS FULL HEIGHT TO DECK ABOVE. TYPE F2 1 HOUR RATED WALL UL# U419 PROVIDE TYPE "X" GYPSUM WALLBOARD FOR 1 HR UL RATING ON EACH SIDE OF 6" 20 GA. METAL STUDS @ 16" O.C. WITH 6" SOUND ATTENUATION BLANKETS IN STUD SPACE. EXTEND STUDS, BOARD, AND BLANKETS FULL HEIGHT TO DECK ABOVE. NOTES: 1. TYPICAL PARTITION TYPE IS WALL TYPE "A1" UNLESS NOTED OTHERWISE ON PLAN. 2. BUILD PARTITIONS IN ACCORDANCE WITH PARTITION SCHEDULE AND DESIGN REFERENCED. REFERENCES ARE TO THE LATEST EDITION OF GYPSUM ASSOCIATION (GA) FIRE RESISTANCE DESIGN MANUAL, OR TO UNDERWRITERS LABORATORY (UL) FIRE RESISTANCE DIRECTORY. 3. ALL WALLBOARD IS TO BE TYPE "X" UNLESS NOTED OTHERWISE. 4. NO EXISTING FIREPROOFING IS TO BE REMOVED FROM EXISTING BUILDING STRUCTURE FOR ANY NEW INSTALLATION FOR ANY REASON. REPAIR ANY FIREPROOFING DAMAGED BY CONSTRUCTION TO MATCH EXISTING SYSTEM. 5. FLOOR TO FLOOR HEIGHT IS TO BE VERIFIED IN THE FIELD BY THE CONTRACTOR. 6. ALL INTERIOR METAL STUD PARTITIONS ARE TO HAVE A 2 1/2" DEEP TOP TRACK FOR DEFLECTION COMPENSATION. DO NOT SCREWATTACH STEEL VERTICAL STUDS OR GYPSUM WALLBOARD TO TOP DEFLECTION TRACK. UNLESS NOTED, THE CONNECTION AT THE TOP OF THE PARTITION TO THE STRUCTURE ABOVE MUST ALLOW FOR 1" MINIMUM VERTICAL MOVEMENT, EITHER UP OR DOWN. AT FIRE RATED METAL STUD PARTITIONS, THE TOP CONNECTION MUST BE A FIRE STOP CONNECTION THAT ALLOWS 1" MINIMUM VERTICAL MOVEMENT, EITHER UP OR DOWN. HOLD GYPSUM WALL BOARD AND STEEL STUDS 1" FROM THE BOTTOM OF THE STRUCTURE ABOVE. DO NOT SCREW-ATTACH STEEL VERTICAL STUDS OR GYPSUM WALL BOARD TO THE TOP TRACK. INSTALL BRIDGING 12" MINIMUM FROM THE TOP OF THE STUDS. 7. PARTITION TYPES INDICATED ARE CONTINUOUS TO A CORNER OR AN INTERSECTING PARTITION, UNLESS INDICATED OTHERWISE. WHERE PARTITIONS OF DIFFERENT THICKNESS MEET, MAINTAIN A FLUSH SURFACE ON THE SIDE WHERE FACES ARE STRAIGHT AND CONTINUOUS, UNLESS NOTED OTHERWISE. 8. METAL STUD GAUGES SCHEDULED ARE THE MINIMUM REQUIRED, AND MAY BE INCREASED BY SPECIFICATIONS TO ACCOMMODATE LOADS, FINISHES, OR UNBRACED CEILING HEIGHT LIMITS. DO NOT CONSIDER CEILING SYSTEM(S) AS A PARTITION BRACING ELEMENT. 9. SOUND ATTENUATION BATT (SAB) IS TO BE PLACED IN ALL PARTITIONS WHICH ENCLOSE A ROOM UNLESS NOTED OTHERWISE. 10. WOOD AND PLYWOOD BLOCKING TO BE FIRE RETARDANT TREATED (FRT). 11. EDGES OF GYPSUM WALL BOARD (GWB) LEFT EXPOSED TO VIEW, OR ABUTTING DISSIMILAR MATERIAL, IS TO BE FINISHED WITH METAL "L" BEAD TRIM AND COMPOUND UNLESS NOTED OTHERWISE. 12. SCHEDULING OF A PARTITION DESIGN WHICH CARRIES A FIRE RATING DOES NOT IMPLY A FIRE SEPARATION FUNCTION FOR THAT PARTITION. LOCATIONS OF FIRE AND SMOKE PARTITIONS ARE INDICATED ON THE LIFE SAFETY PLAN. 13. 1PARTITION SCHEDULE IS BASED ON THE USE OF GYPSUM WALL BOARD (GWB), BUT FACING BOARD MAY VARY, DEPENDENT ON FINAL FINISH SCHEDULED FOR THAT PARTITION: USE CEMENTITIOUS BACKER BOARD (CBB) WHERE CERAMIC TILE SCHEDULED IN "WET" AREAS; USE MOISTURE RESISTANT BOARD (MR) WHERE CERAMIC TILE SCHEDULED IN "DRY" AREAS; USE GYPSUM LATH (BLUE BOARD) WHERE VENEER PLASTER IS SCHEDULED. SEE FINISH SCHEDULE AND SPECIFICATIONS FOR PARTICULARS. AT ALL PLUMBING FIXTURES INSTALL 4X8 (MR) MOISTURE RESISTANT BOARD CENTERED ON FIXTURE. 14. ALL FIRE RATED WALL AND FLOOR PENETRATION MUST COMPLY WITH ASTM-E814 15. ALL DOOR OPENINGS SHALL BE 4" FROM A PERPENDICULAR PARTITION TO OUTSIDE FACE OF FRAME, UNLESS NOTED OR DETAILED OTHERWISE. 16. ALL PARTITIONS, INCL. STUDS, BOARD, SOUND ATTENUATION BLANKETS, ETC. TO EXTEND FROM TOP OF FLOOR SLAB TO UNDERSIDE OF CONCRETE SLAB ABOVE UNLESS OTHERWISE NOTED. 17. CONTRACTOR IS TO CLOSE OFF ANY VOIDS LEFT AS A RESULT OF ANY REMOVALS AND NEW CONSTRUCTION, AS WELL AS INFILL ANY EXISTING VOIDS IN NEWLY DESIGNATED FIRE RATED PARTITIONS. ALL PATCHES SHALL MATCH AND ALIGN WITH SURROUNDING MATERIALS AND SHALL BE IN ACCORDANCE WITH OHIO BASIC BUILDING CODE. 18. REFER TO ARCHITECTURAL FLOOR PLANS FOR PARTITION TYPE DESIGNATIONS. 19. CONTRACTOR SHALL SEAL PARTITION WALLS AROUND ALL M.E.P. PENETRATIONS OR OPENINGS, RESULTING FROM M.E.P. INSTALLATIONS INCLUDING BUT NOT LIMITED TO THE SLAB, ABOVE AND BELOW CEILINGS. PARTITION TYPES 33. 34. 35. 36. 37. 38. 39. 40. 41. 42. thinkchamplin.com GALLAGHER CENTER STUDENT CENTER RENOVATION XAVIER UNIVERSITY 3800 VICTORY PKWY CINCINNATI, OH 45207 ISSUANCES No. Description Date 1 ISSUED FOR BID/ PERMIT 3/21/2016 GENERAL NOTES WHERE BLOCKING ATTACHES TO OPEN SIDE OF WALL STUD, PROVIDE 20 GA. TRACK x 8" LONG. SCREW TO STUD W/ 4 - NO.10-16 SCREWS EA. SIDE PIPE SLEEVE WHERE BLOCKING ATTACHES TO THE OPEN SIDE OF WALL STUD, PROVIDE 20 GA. TRACK x 7 1/4" LONG. SCREW TO STUD W/ 4 - NO.10-16 SCREWS EA. SIDE. 12 GA.CLIP ANGLE 2"x2"x7 1/2" TALL W/ 4 - NO. 10-16 SCREWS IN EA. LAG. FILL MATERIAL (DEPTH TO BE MIN. 1/2") BLOCKING = 2x8 FIRE RETARDANT TREATED WOOD, (FRTW). USE SPRUCE PINE FIR NO. 2, TREATED W/ DRICON BLOCKING = 8" DEEP x 14 GA. TRACK W/ 1 1/4" FLANGES 1/2" PLAN VIEW BLOCKING = 18 GA. x 8" MIN. TALL SHEET STEEL. SCREW TO STUDS W/ 4 - NO. 10-16 SCREWS @ EA. END. PROVIDE ONE ADDITIONAL SCREW EA. END FOR EACH 2" ADDITIONAL HEIGHT INCREASE IN THE BLOCKING PLATE. IF BLOCKING PLATE IS CONTINUOUS @ A WALL STUD, PROVIDE 2 ROWS OF SCREWS. 32. 720 E Pete Rose Way #140 Cincinnati, OH 45202 T 513.241.4474 F 513.241.0081 SEE PLAN 1/2" MIN. DISTANCE FROM EDGE OF PLATE TYP. 31. ALL WORK SHALL BE DONE IN ACCORDANCE WITH APPLICABLE LOCAL, STATE AND FEDERAL AUTHORITIES, CODES, RULES AND REGULATIONS. THESE DOCUMENTS SHOW THE MINIMUM CONSTRUCTION REQUIREMENTS AND THE MINIMUM QUALITY OF WORK EXPECTED. MORE STRINGENT REQUIREMENTS STIPULATED WITHIN RELEVANT MANUFACTURER’S INSTALLATION INSTRUCTIONS WILL SUPERSEDE. ANY UNFORESEEN OR UNCLEAR CONDITIONS SHALL BE REPORTED TO THE ARCHITECT PRIOR TO PROCEEDING WITH WORK. ANY CONFLICTS WITHIN THE DRAWINGS, BETWEEN THE DRAWINGS AND THE SPECIFICATIONS, OR BETWEEN THE DRAWINGS AND THE ACTUAL CONDITIONS AT THE SITE, ARE TO BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT. THE CONTRACTOR SHALL NOT PROCEED WITH WORK UNTIL WRITTEN CLARIFICATION FROM THE ARCHITECT IS RECEIVED. UNLESS OTHERWISE NOTED, ALL MATERIALS AND EQUIPMENT ARE TO BE INSTALLED PER THE APPLICABLE PROVISIONS OF THESE DOCUMENTS AND THE MANUFACTURER’S INSTRUCTIONS. ALL MATERIALS USED ARE REQUIRED TO BE NEW UNLESS OTHERWISE NOTED AND/OR OF A QUALITY TO MEET OR EXCEED ALL APPLICABLE INDUSTRY STANDARDS. WHERE SPECIFIED PRODUCTS OR MANUFACTURERS ARE NOT NOTED, THE CONTRACTOR IS REQUIRED TO NOTIFY THE ARCHITECT TO OBTAIN A MINIMUM STANDARD OF QUALITY. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL MEANS, METHODS AND TECHNIQUES FOR CONSTRUCTION. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR JOB-SITE SAFETY INCLUDING BUT NOT LIMITED TO THE ADHERENCE TO OSHA REGULATIONS. ALL ELECTRICAL AND MECHANICAL WORK SHALL BE PERFORMED BY PERSONNEL LICENSED IN THE STATE WHERE THIS PROJECT IS LOCATED. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR THE PROTECTION OF EXISTING ITEMS TO REMAIN DURING DEMOLITION AND CONSTRUCTION. REMOVE ALL DEBRIS PROPERLY FROM THE SITE. LOAD DEBRIS DIRECTLY ONTO TRUCKS OR INTO DUMPSTERS FOR REMOVAL. DISPOSE OF DEBRIS LEGALLY. DO NOT BURN DEBRIS ON THE SITE. DO NOT ALLOW DEBRIS TO ENTER SEWERS. DO NOT ALLOW PILED DEBRIS TO ENDANGER STRUCTURES, BLOCK EXISTS OR ROADWAYS. COMBUSTIBLE WASTE WHICH COULD CREATE A FIRE HAZARD SHALL NOT BE PERMITTED TO ACCUMULATE IN OR AROUND THE CONSTRUCTION SITE. DO NOT SCALE DRAWINGS. DIMENSIONS SHALL GOVERN. ALL PLAN DIMENSIONS ARE TAKEN TO FINISH FACE OF CONSTRUCTION. LAYOUT AND VERIFY ALL PARTITION LOCATIONS PRIOR TO CONSTRUCTION FOR CLEARANCES AND DIMENSIONS. NOTIFY ARCHITECT OF ANY DISCREPANCIES. WITHIN ALL METAL STUD PARTITIONS, THE GENERAL CONTRACTOR IS TO PROVIDE BLOCKING FOR ALL WALL MOUNTED EQUIPMENT AND ACCESSORIES INCLUDING BUT NOT LIMITED TO: MECHANICAL, ELECTRICAL AND PLUMBING DEVICES, FURNITURE, CASEWORK, MILLWORK AND ALL OTHER WALL MOUNTED ACCESSORIES AND ITEMS. THE LOCATIONS, MOUNTING HEIGHTS AND BLOCKING REQUIREMENTS SHOWN HEREON ARE GIVEN FOR INFORMATIONAL PURPOSES ONLY AND IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO VERIFY THIS INFORMATION WITH THE ASSOCIATED SUB-CONTRACTORS, MANUFACTURERS, OR EQUIPMENT SUPPLIERS. SEE TYPICAL BLOCKING DETAILS IN METAL STUD WALLS INCLUDED IN THESE DOCUMENTS FOR BLOCKING AND ANCHORING REQUIREMENTS. ALL CONCEALED WOOD SHALL BE FIRE RETARDANT TREATED. THE GENERAL CONTRACTOR SHALL COORDINATE WITH ALL OTHER DISCIPLINES INCLUDING BUT NOT LIMITED TO MECHANICAL, ELECTRICAL AND PLUMBING, TO DETERMINE THE SIZE AND LOCATION OF ALL PENETRATIONS IN NEW CONSTRUCTION. COORDINATE AND PROVIDE ALL OPENINGS. SEAL CONSTRUCTION TIGHT TO ALL PENETRATIONS AND CAULK. ALL PENETRATIONS THROUGH FIRE RATED CONSTRUCTION MUST BE FIRE SAFED IN ACCORDANCE WITH THE SPECIFICATIONS. PROVIDE CONTROL JOINTS IN GYPSUM WALLBOARD INTERIOR PARTITIONS AT 30 FEET ON CENTER MAXIMUM. WHERE POSSIBLE, LOCATE AT CORNERS ABOVE OPENINGS. VERIFY LOCATIONS WITH ARCHITECT. SEE THE ASSOCIATED TYPICAL DETAILS INCLUDED IN THESE DOCUMENTS. FURNISH AND INSTALL SEALANT AT ALL FIXTURES AND CHANGES IN MATERIAL, AND AS REQUIRED BY THE APPLICABLE HEALTH DEPARTMENT. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATING ALL EQUIPMENT INSTALLATION AND VERIFYING ALL REQUIRED ROUGH OPENINGS, AND ROUGH-IN DIMENSIONS WITH THE EQUIPMENT MANUFACTURER, OWNER AND ARCHITECT PRIOR TO CONSTRUCTION. THE GENERAL CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND FIELD CONDITIONS PRIOR TO DEMOLITION AND CONSTRUCTION. IF PROVIDED, THE GENERAL CONTRACTOR SHALL CAREFULLY EXAMINE EXISTING BUILDING DOCUMENTS. THE CONTRACTOR SHALL BRING ANY DISCREPANCIES TO THE IMMEDIATE ATTENTION OF THE ARCHITECT. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR THE PROTECTION OF EXISTING ITEMS TO REMAIN DURING DEMOLITION AND CONSTRUCTION. MAINTAIN EXIT EGRESS PATHS TO EXISTING EXIT DOORS DURING CONSTRUCTION. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR THE PROTECTION OF ALL CONSTRUCTION ROUTES BEYOND THE AREAS OF WORK AND THE ROUTES MUST BE RETURNED TO THEIR ORIGINAL CONDITION AT THE END OF THE PROJECT. MAINTAIN THE BUILDING IN A WEATHER TIGHT CONDITION AT ALL TIMES. ALL DEMOLITION AND CONSTRUCTION ACTIVITIES SHALL BE COORDINATED WITH THE OWNER TO MINIMIZE DISRUPTIONS OF NORMAL FUNCTIONS OF THE OWNER'S OCCUPIED AREAS. IF CONSTRUCTION NOISE IS ANTICIPATED, SUBMIT A WRITTEN REQUEST TO THE OWNER FOR THE SCHEDULED TIME OF THE CONSTRUCTION ACTIVITIES. NO WORK SHALL BE DONE WITHOUT THE WRITTEN APPROVAL OF THE OWNER. THE OWNER RESERVES THE RIGHT TO DISCONTINUE NOISY CONSTRUCTION AT ANY TIME. ALL EXISTING SERVICES AND UTILITIES SHALL BE MAINTAINED TO ADJACENT AREAS THAT ARE IN OPERATION AND SERVED BY THEM. COORDINATE ALL DISRUPTIONS OR DISCONTINUATIONS OF UTILITIES AND SERVICES WITH OWNER. NO SHUT DOWN OF EXISTING SERVICES IS ALLOWED TO OCCUR UNTIL RECEIVING THE OWNER'S WRITTEN APPROVAL OF THE SHUT DOWN SCHEDULE. PROVIDE TEMPORARY SERVICES AND/OR UTILITIES DURING INTERRUPTIONS AS REQUIRED AND APPROVED BY THE OWNER. THE GENERAL CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO PREVENT DAMAGE TO OWNER'S OCCUPIED AREAS ADJACENT TO NEW CONSTRUCTION OR OCCUPIED AREAS WHERE VARIOUS SYSTEM CONNECTIONS OR EXTENSIONS ARE REQUIRED. IN THESE AREAS, THE GENERAL CONTRACTOR IS RESPONSIBLE FOR DAMAGE CAUSED BY LACK OF SUFFICIENT PROTECTION FROM THE WEATHER AND FROM THE RESULTS OF ALL CONSTRUCTION ACTIVITY INCLUDING BUT NOT LIMITED TO DUST AND WATER. TEMPORARY BARRICADES WHERE INDICATED ON THE DOCUMENTS ARE SHOWN IN THEIR APPROXIMATE LOCATIONS. THE GENERAL CONTRACTOR MUST COORDINATE SPECIFIC LOCATIONS WITH THE OWNER IN CONJUNCTION WITH THE CONSTRUCTION PHASING. TEMPORARY BARRICADES MUST BE CONSTRUCTED IN ACCORDANCE WITH OSHA REQUIREMENTS AND OWNER'S INTERIM LIFE SAFETY MEASURES. DURING CONSTRUCTION, ISOLATE ALL HVAC SYSTEMS IN AREAS WHERE THE WORK IS BEING PERFORMED. COMPLETE ALL CRITICAL BARRIERS TO SEAL THE WORK AREA FROM THE REST OF THE FACILITY. MAINTAIN NEGATIVE AIR PRESSURE WITHIN THE WORK SITE USING HEPA EQUIPPED AIR FILTRATION UNITS. PROMPTLY SEAL ANY HOLES/PENETRATIONS BETWEEN THE WORK AREA AND THE REST OF THE FACILITY. CONTAIN CONSTRUCTION WASTE IN COVERED CONTAINERS BEFORE TRANSPORTING IT. THE GENERAL CONTRACTOR SHALL RECEIVE WRITTEN APPROVAL FROM THE OWNER BEFORE USING OPEN FLAMES, WELDING RODS AND TORCHES. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL MEANS AND METHODS TO PROHIBIT THE MIGRATION OF SMOKE AND OTHER PRODUCTS OF COMBUSTION INTO OCCUPIED AREAS OF THE EXISTING BUILDING AND FOR OBTAINING ALL REQUIRED PERMITS RELATED TO HOT WORK. PROVIDE FIRE PROTECTION IN ACCORDANCE WITH THE REQUIREMENTS OF THE GOVERNING AUTHORITY. IT IS THE GENERAL CONTRACTORS RESPONSIBILITY TO PATCH ALL SPRAY-ON FIRE PROTECTION AT REMOVALS, AT ANY EXISTING LOCATIONS WHICH ARE VOID OF PROTECTION WITHIN THE AREA OF WORK AND AT NEW CONSTRUCTION WHICH DISTURBS EXISTING FIRE PROTECTION. FIREPROOFING MUST BE CONTINUOUS AND UNOBSTRUCTED. DO NOT OVERLOAD THE EXISTING BUILDING STRUCTURE. MAINTAIN THE STRUCTURAL INTEGRITY OF ALL STRUCTURAL FRAMING MEMBERS AND SYSTEMS AT ALL TIMES. ALL OPENINGS IN EXISTING WALLS, CEILINGS AND FLOORS, WHICH ARE THE RESULT OF REMOVALS AND OTHER NEW CONSTRUCTION ACTIVITY, SHALL BE PATCHED WITH NEW MATERIALS THAT MATCH THE EXISTING MATERIALS. IF THE PATCH IS TO BE MADE IN FIRE RATED CONSTRUCTION, THE PATCH MUST ACHIEVE THE REQUIRED FIRE RATING. THE PATCH SHALL BE FINISHED TO A LIKE NEW CONDITION TO MATCH THE EXISTING FINISH. ALL EXISTING OPENINGS IN CEILINGS, FLOORS AND WALLS DISCOVERED IN THE EXISTING STRUCTURE SHALL BE PATCHED WITH NEW MATERIALS THAT MATCH THE EXISTING MATERIALS. IF THE PATCH IS TO BE MADE IN FIRE RATED CONSTRUCTION, THE PATCH MUST ACHIEVE THE REQUIRED FIRE RATING. THE PATCH SHALL BE FINISHED TO A LIKE NEW CONDITION TO MATCH THE EXISTING FINISH. WHERE EXISTING SURFACES ARE TO BE REFINISHED OR ARE TO SERVE AS SUBSTRATE FOR THE ATTACHMENT OR APPLICATION OF NEW MATERIALS OR CONSTRUCTION, PREPARE OR ALTER THE EXISTING SURFACES AS NECESSARY TO PROPERLY ACCOMMODATE THE NEW MATERIALS. FIELD VERIFY SIZES AND DIMENSIONS OF ALL EXISTING UTILITIES THAT IMPACT THE NEW WORK. DETERMINE THE SIZE AND LOCATION THE PENETRATIONS FROM THE EXISTING UTILITIES WITHIN THE NEW WORK. SEAL TIGHT TO ALL PENETRATIONS AND CAULK. PENETRATIONS THROUGH EXISTING FIRE RATED CONSTRUCTION MUST BE PROPERLY CLOSED AND FIRE SAFED TO ACHIEVE THE PROPER FIRE RATING BY THE END OF CONSTRUCTION OPERATIONS FOR EACH DAY. UNLESS OTHERWISE NOTED, THE GENERAL CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL EXISTING SALVAGED STOCK BEFORE ORDERING NEW MATERIAL. ROOM IDENTIFICATION SIGNAGE IS REQUIRED TO MEET THE REQUIREMENTS FOR CHARACTER HEIGHT AND PROPORTION, FINISH AND CONTRAST, FRONT, BRAILLE AND PICTOGRAM TYPES AS INDICATED IN THESE DOCUMENTS. ROOM IDENTIFICATION SIGNAGE SHALL BE MOUNTED AT 60" ABOVE THE FINISHED FLOOR TO THE SIGN CENTERLINE AND SHALL BE MOUNTED TO THE WALL AT THE LATCH SIDE OF THE DOOR. 3/4" MAX. TYP. OPTION A - PLAN VIEW PLAN VIEW WHERE BLOCKING ATTACHES TO OPEN SIDE OF WALL STUD, PROVIDE 20 GA. TRACK x 8" LONG. SCREW TO STUD W/ 4 - NO.10-16 SCREWS EA. SIDE BLOCKING = 8" DEEP x 14 GA. TRACK W/ 1 1/4" FLANGES CLIP & BEND FLANGES EA. END. CONNECT EA. END W/ 4 - NO.10-16 SCREWS 1" (MIN.) SAFING INSULATION PACKED TIGHT AROUND PIPE SCREW THROUGH STUD OR TRACK INTO THE END OF THE WOOD BLOCKING W/ 4 NO. 9-18 x 1 1/2" CUT THREAD WOOD SCREWS. SCREWS SHALL HAVE A PROTECTIVE COATING. AN ACCEPTABLE FASTERNER IS BUILDEX 918 x 1 1/2" HWH TRUGRIP COATED W/ CLIMASEAL. 1/2" MIN. PROJECTION TO A MAX. 2" METAL PIPE OR CONDUIT THIS DETAIL IS DIAGRAMMATIC ONLY, MFR. OF FIRESTOP MATERIALS SHALL PROVIDE FINAL DESIGN AND APPLICABLE U.L. DESIGN NUMBERS. A A001 WALL PENETRATION - 1 HR & 2HR RATED PARTITION 1 1/2" = 1'-0" Drawn By OPTION B - PLAN VIEW ELEVATION VIEW Checked By - ELEVATION VIEW CLOCK THE CONTRACTOR MUST COORDINATE WITH ALL TRADES TO DETERMINE WHICH TYPE OF WALL BLOCKING IS REQUIRED FOR EACH WALL MOUNTED ITEM. ALL ANCHORS SHALL EXTEND THROUGH THE WALL FINISH INTO THE BLOCKING. AVOID THE USE OF PLASTIC TYPE ANCHOR DEVISES. MANUFACTURERS OF THE WALL MOUNTED ITEMS MUST PROVIDE THE PULLOUT AND SHEAR FORCES AT THE ANCHORS DUE TO THE WEIGHT OF THE ITEM AS WELL AS THE LOADS THAT ARE REQUIRED TO BE SUPPORTED BY THE ITEM AS MANDATED BY THE GOVERNING AUTHORITY. ANCHORS MUST HAVE ADEQUATE STRENGTH TO SUPPORT THESE FORCES. CONTRACTOR HAS THE OPTION TO USE A PROPRIETARY BLOCKING SYSTEM WHICH MUST BE SUBMITTED TO THE ARCHITECT FOR APPROVAL. 1HR PARTITION - SEE FLOOR PLAN & PARTITION TYPE SCHEDULE FOR REQUIREMENTS B A001 4'-0" 4'-0" 1'-6" DEFLECTIONI TRACK ATTACH TO CLOSURE PLATE WALL BLOCKING TYPE 2 OR 3: TO BE USED FOR ALL OTHER WALL MOUNTED ITEMS NOT MEETING THE REQUIREMENTS FOR WALL BLOCKING TYPE 1. WALL BLOCKING DETAILS 4'-0" WALL BLOCKING TYPE 1: TO BE USED FOR WALL MOUNTED ITEMS THAT WEIGH 50 POUNDS OR LESS AND THAT ARE NOT INTENDED FOR HUMAN SUPPORT. EXAMPLES OF WALL MOUNTED ITEMS THAT ARE INTENDED FOR HUMAN SUPPORT ARE HANDRAILS AND GRAB BARS. THESE CANNOT HAVE WALL BLOCKING TYPE 1. FIRE EXTINGUISHER CABINET ELECTRICAL OUTLET ELECT THERMOSTAT SWITCH TEST REF.: SIMILAR TO JMI/PHV 60-01 TYP. RATED WALL PARALLEL TO ROOF DECK - 1HR RATED 1 1/2" = 1'-0" TYPICAL MOUNTING HEIGHTS MONITOR/ TV 07009 TE Project Number 5264 OWNER PROVIDE FIRE SEALANT @JOINT AND OVER ENTIRE CLOSURE PLATE (TYP. BOTH SIDES) NOTES: COOD W WALL BLOCKING TYPE 3 7'-0" WALL BLOCKING TYPE 2 Client Number 81 IS WALL BLOCKING TYPE 1 CL I M. J. BATTOCLETTE R EG OPTION A - ELEVATION VIEW OPTION B - (SIMILAR) ROOF/FLOOR SLAB SEE STRUCTURAL DRAWINGS E O F OH O KPN AT R E D A RC H M. J. BATTOCLETTE LICENSE #07009 EXPIRATION DATE 12/31/2017 ARCHITECTURAL GENERAL NOTES, SYMBOLS, & TYP DETAILS A001 3/21/2016 7:48:56 PM SIM F.HORN F.H.S. FH.W.S. LEFT HAND LIVE LOAD LOW POINT LIGHT EC T 1 A101 F.F. F.G. FGL. F.H. FH.M.S. FACE FIRE ALARM FACE BRICK FIREBOARD FIRE BELL FURNISHED BY OTHERS FLOOR DRAIN FOUNDATION FIRE EXTINGUISHER FIRE EXTINGUISHER CABINET FINISH FLOOR FINISH GRADE FIBERGLASS FIRE HYDRANT FLAT HEAD MACHINE SCREW FIRE HORN FIRE HOSE STATION FLAT HEAD WOOD SCREW FINISH FIXTURE FLOOR JOIST FLOOR LINE FLASHING FLUORESCENT FLOOR FACE NAIL FACE OF BUILDING FACE OF CONCRETE FACE OF FINISH FACE OF MASONRY FACE OF STUD FIRE RETARDANT TREATED WOOD FIRE SUPPRESSION CONTRACTOR FOOD SERVICE EQUIPMENT CONTRACTOR FOOTING FUTURE FIRE VALVE CABINET L.H. L.L. L.P. LT. IT 0 F. F.A. F.B. F.BD. F.BELL F.B.O. F.D. FDN. F.E. F.E.C. ENCLOSURE EQUIVALENT EACH SIDE EACH WAY ELECTRIC WATER CLOSET EXPANSION EXPANSION BOLT EXPOSURE EXTERIOR ST Name Elevation ENCL. EQUIV. E.S. E.W. E.W.C. EXP. EXP.B. EXPO. EXT. & < @ CL Ø FL PL # DEMOLITION PLAN LEGEND 4 PARTITIONS AND CASEWORK TO BE REMOVED. PARTITIONS AND CASEWORK TO REMAIN. PROTECT ITEMS TO REMAIN DURING DEMOLITION AND NEW WORK. DOOR AND FRAME TO BE REMOVED. DOOR AND FRAME TO REMAIN. PROTECT ITEMS TO REMAIN DURING DEMOLITION AND NEW WORK. A 12 19 HATCHED AREA - INTERIOR DEMOLITION AREA • REMOVE ALL INTERIOR FINISHES, INCLUDING BUT NOT LIMITED TO: INTERIOR PARTITIONS, CEILINGS, FLOOR FINISHES, EQUIPMENT, RUBBER OR WOOD BASE, CASEWORK AND ITEMS MOUNTED ON WALLS AND CEILINGS REMAINING ETC. • SALVAGE 2X4 LIGHTS TO BE REINSTALLED IN NEW WORK. ANY LIGHTS THAT ARE NOT USED ARE TO BE RETURNED TO OWNER. COORDINATE WITH CEILING PLAN AND ELECTRICAL DRAWINGS. • SALVAGE UNDAMAGED FULL ACOUSTICAL CEILING TILES THIS AREA. AT NEW WORK, USE THIS STOCK TO REPLACE DAMAGED CEILING TILES IN ROOM 109 AND AT MODIFIED CEILING WORK. RETURN REMAINING ATTIC STOCK TO OWNER. • COORDINATE THE REMOVAL OF MECHANICAL, ELECTRICAL, SECURITY AND PLUMBING ITEMS WITH MEPT DRAINING. • PROTECT ITEMS TO REMAIN DURING DEMOLITION AND NEW WORK. • SEE GENERAL NOTES AND KEYNOTES FOR ITEMS TO BE SALVAGED AND ADDITIONAL SCOPE. 5 13 5 13 14 5 3 720 E Pete Rose Way #140 Cincinnati, OH 45202 T 513.241.4474 F 513.241.0081 17 18 thinkchamplin.com 1 8 5 HATCHED AREA - LIMITED DEMOLITION • NO WORK AT FLOORING • CEILING SYSTEM, MINI-BLINDS AND DEVICES TO REMAIN. COORDINATE WITH NEW WORK. • COORDINATE THE REMOVAL OF MECHANICAL, ELECTRICAL, SECURITY AND PLUMBING ITEMS WITH MEPT DRAINING. • PROTECT ITEMS TO REMAIN DURING DEMOLITION AND NEW WORK. • SEE GENERAL NOTES AND KEYNOTES FOR ITEMS TO BE SALVAGED AND ADDITIONAL SCOPE. ALTERNATE • #A01 - REMOVE FLOORING SYSTEM AND BASE (BOOKSTORE). 4 6 12 19 3 5 1 NO WORK THIS AREA 13 B 1 2 LEGEND 7 15 3 15 1 10 21 7 20 1 1 GALLAGHER CENTER STUDENT CENTER RENOVATION 11 16 C XAVIER UNIVERSITY 3800 VICTORY PKWY CINCINNATI, OH 45207 9 ISSUANCES 9 9 9 No. Description Date 1 ISSUED FOR BID/ PERMIT 3/21/2016 D DEMOLITION PLAN GENERAL NOTES A. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 1 AD101 LEVEL 1 - DEMOLITION PLAN 3/16" = 1'-0" C. D. E. F. Checked By Client Number 81 I 07009 TE Project Number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rawn By R E D A RC H M. J. BATTOCLETTE LICENSE #07009 EXPIRATION DATE 12/31/2017 ARCHITECTURAL LEVEL 1 DEMOLITION PLAN AD101 3/21/2016 7:50:45 PM DEMOLITION PLAN KEYNOTES 5 EC T 3 IT 2 ST 1 4 22'-6" 3 A103 RA Sim 3 A103 BORROWED LITE -110C SEE DOOR SCHEDULE. A GL 720 E Pete Rose Way #140 Cincinnati, OH 45202 T 513.241.4474 F 513.241.0081 GL + 9" TYP TYP /- thinkchamplin.com F1 1 Sim A A104 A103 F1 STUDENT LOUNGE 5 3'-6" 110 3'-6" 30'-0" 7'-0" 110 1 8'-0" EQUAL Sim 1'-0 1/2" +/- 8 2 10 1/2" +/- 1'-6 1/2" +/- 110C 27'-5" +/- STOR ATRIUM 110C 111 3 5'-8 1/2" +/2 2 7 L EQUA 2'-10" +/- 2 A103 2 A103 1 Sim B F1 A7 A103 A103 110B 12'-0" +/- 3 WD A7 5 STOR EQ 110B 3 110A WD WD STOR EQ 1 F1 8 9'-4" +/- A7 EQ 1-C 8 8 TYP 13'-4" B7 STAIR C 6 Sim EQ TYP 1 GL 2'-8" ST1-Ca 1'-0 1/2" +/- GL 110A F1 ST1-Cb 8'-2 1/2" +/- 4 8'-0 1/2" F1 5'-8" 5'-8" 8'-0 1/2" 6'-9" +/- 5 3/4" 30'-0" 6 C1 7 7 A103 A105 7 GALLAGHER CENTER STUDENT CENTER RENOVATION BOOKSTORE 109 C CORR OFFICE 108 107 30'-0" XAVIER UNIVERSITY 3800 VICTORY PKWY CINCINNATI, OH 45207 ISSUANCES No. Description Date 1 ISSUED FOR BID/ PERMIT 3/21/2016 D 30'-0" 2 3 5 Checked By 4. 5. 6. 7. 8. 1 A101 LEVEL 1 - FLOOR PLAN 3/16" = 1'-0" ALIGN WITH EXISTING WALL ALIGN WALL PROTECTION PANEL. TYPICAL ALL WALL THIS ROOM. SEE MATERIAL AND FINISH SCHEDULE AND NOTES. CARD READER. SEE DOOR SCHEDULE AND ELECTRICAL DRAWINGS. PROJECTION SCREEN ABOVE. 1-HOUR PROTECTION TO BE CONTINUOUS TO STRUCTURE. WHEN RATED PARTITION, CANNOT EXTEND VERTICALLY TO THE STRUCTURE DUE TO THE DUCT MAIN INTERFERENCE, PROVIDE A 1-HOUR RATED HORIZONTAL TRANSITION. SEE SHEET A001 FOR DETAILS. ADA-COMPLIANT ENTRY SIGNAGE FOR "STUDENT LOUNGE" MATCHING BUILDING STANDARDS. COORDINATE WITH OWNER ADA-COMPLIANT ROOM SIGNAGE. MATCH BUILDING STANDARDS. COORDINATE WITH OWNER. A. B. C. D. SEE A001 FOR PROJECT NOTES. PATCH AND REPAIR AREAS DISTURBED BY DEMOLITION. SEE SHEET A001 NOTES. PATCH, REPAIR AND PAINT DAMAGED COLUMN FURRING IN ALL AREAS OF WORK, INCLUDING AREAS TO RECEIVED FINISH MATERIAL. COORDINATE WITH OWNER ON SIGNAGE INSTALLATION REQUIREMENTS. NO WORK THIS AREA Client Number 81 07009 TE Project Number 5264 I IT - IS 1. 2. 3. FLOOR PLAN GENERAL NOTES E O F OH M. J. BATTOCLETTE R EG FLOOR PLAN KEYNOTES AT O KPN ST Drawn By R E D A RC H M. J. BATTOCLETTE LICENSE #07009 EXPIRATION DATE 12/31/2017 LEVEL 1 ARCHITECTURAL FLOOR PLAN A101 3/21/2016 7:49:14 PM 1 30'-0" EC T 24'-0" SEE ELECTRICAL DRAWINGS FOR FIXTURE TYPES CEILING PLAN GENERAL NOTES B. 2' X 2' LIGHT FIXTURE RECESSED DOWNLIGHT C. GYPSUM WALL BOARD CEILING CONTROL JOINT CJ RETURN REGISTER - SEE MECH. DWGS. SUPPLY - SEE MECH. DWGS. D. EXHAUST - SEE MECH. DWGS. E. SPRINKLER - SEE MECH. DWGS. 5 A105 ACT-1 11' - 0"A.F.F. A WC-1 9' - 4"A.F.F. 10 13 TYP ACT-1 10' - 0"A.F.F. ACT-2 9' - 4"A.F.F. 10 J 5" EXIT SIGN ACT-2 9' - 4"A.F.F. J 2x4 ACT 720 E Pete Rose Way #140 Cincinnati, OH 45202 T 513.241.4474 F 513.241.0081 11 " 11 thinkchamplin.com 11 2x2 ACT OR 4x4 ACT 5 1'-3 " TYP " A105 3 1'- SUSPENDED CEILING ACT-1 TYPICAL U.N.O. ACT-1 11' - 0"A.F.F. J ACCEPTABLE SUSPENDED CEILING WC-1 9' - 4"A.F.F. 10 1'-3 " 2' X 4' LIGHT FIXTURE RECESSED CONTINUOUS WALL WASH 4 SEE DRAWING SHEET A001 FOR GENERAL INFORMATION AND PROJECT ABBREVIATIONS COORDINATE WITH HVAC, PLUMBING, ELECTRICAL AND FIRE SUPPRESSION DOCUMENTS FOR ALL LIGHT FIXTURES, SPRINKLERS, POWER, HVAC, AND MEDICAL GAS OUTLET LOCATION AND TYPES. COORDINATE WITH ARCHITECTURAL RCP FOR LOCATION AND ALIGNMENTS OF FIXTURES WHERE FIXTURES (INCLUDING SPRINKLERS, DIFFUSERS, SMOKE DETECTORS, CAN LIGHTS, ETC.) ARE SHOWN ON PLANS AS ALIGNED; ALIGN FIXTURES IN CENTER OF TILE OR CENTER OF AREA AS GRAPHICALLY SHOWN ON THE CEILING PLAN. NOTIFY ARCHITECT IF THERE ARE ANY DISCREPANCIES. PROVIDE ACCESS PANELS IN HARD CEILINGS AS REQUIRED. LOCATE SPRINKLER HEADS, SMOKE DETECTORS, CAN LIGHTS AND ALL OTHER FIXTURES IN ACOUSTICAL CEILING SYSTEM IN FIELD SO THAT THEY ARE CENTERED IN TILE UNO. REFER TO SKETCH BELOW. 4 1/2" A. 4 1/2" 4" OR 1' X 4' LIGHT FIXTURE 11 " GYPSUM BOARD " 11 CEILING PLAN KEYNOTES ALIGN PATCH AND REPAIR CEILING TO MATCH EXISTING. METAL CEILING TRANSITION TRIM AND DRYWALL SOFFIT, WALL TYPE C1. SEE DETAIL A105. PAINTED DRYWALL SOFFIT. PAINT TO MATCH BOOKSTORE ENTRY SOFFIT. MODIFY EXISTING CEILING GRID FOR NEW WORK. INSTALL SALVAGED ACOUSTICAL CEILING TILES AND CEILING TRIM AND NEW TRIM, AS REQUIRED. REPLACE DAMAGED CEILING TILES WITH SALVAGED CEILING TILES. CEILING RECESSED POWERED PROJECTION SCREEN - SEE ELECTRICAL DRAWINGS. CEILING MOUNTED POWERED PROJECTION SCREEN - SEE DETAIL SHEET A105 AND ELECTRICAL DRAWINGS. LCD PROJECTOR AND SUPPORT,OFOI. COORDINATE WITH OWNER AND THEIR VENDOR FOR FINAL LOCATION. COORDINATE WITH ELECTRICAL DRAWINGS FOR POWER AND DATA REQUIREMENTS. RELOCATED TV AND SUPPORT PIPE, OFCI. COORDINATE WITH TENANT ON FINAL LOCATION. MATCH EXISTING DETAILING AND MANUFACTURER'S REQUIREMENTS. COORDINATE WITH ELECTRICAL DRAWINGS. POWERED ROLLER SHADE CLOTH AND ALUMINUM POCKET CEILING TRIM. SEE DETAIL AND COORDINATE WITH ELECTRICAL DRAWINGS. VERTICAL TRANSITION EXTRUDED PAINTED ALUMINUM CEILING TRIM. SEE DETAIL SHEET A105. BASIS OF DESIGN: ARMSTRONG AXIOM TRANSITIONS TRIM - CEILING TO CEILING STRAIGHT TRANSITION. COLOR TO MATCH MAIN CEILING. EXISTING CEILING ASSEMBLIES TO REMAIN. PATCH AND PAINT AS REQUIRED. DRYWALL SOFFIT, WALL TYPE C1 UNLESS NOTED OTHERWISE. TYPICAL. SEE DETAILS ON SHEET A105. 6. 7. 8. 9. 10. 11. 12. 13. PT 8' - 8 1/2"A.F.F. " 11 1'-0" NO WORK THIS AREA 6 " 11 5. 10 3" 4. LED LIGHT 2 J 13 PT 11' - 6"A.F.F. 3 ACT-1 10' - 0"A.F.F. J 8 3 " 11 ACCESS PANEL B ACT-2 9' - 4"A.F.F. 13 1 5 " 11 ACT-1 10' - 0"A.F.F. 12 11 " ACT-2 10' - 0"A.F.F. 3" 3. J PROJ. LIGHT COVE 4 PROJ. 1. 2. 3" 1'1'-3 " 1'-3" LINEAR DIFFUSER 8 J PT 10' - 10"A.F.F. J WC-1 9' - 4"A.F.F. 5 1'-7 7/8" WOOD ACOUTICAL PANEL SYSTEM " 11 5 11 7 11 FP ACCESS PANEL 12 - 7 --- A105 7 9 A103 GALLAGHER CENTER STUDENT CENTER RENOVATION C 5 XAVIER UNIVERSITY 3800 VICTORY PKWY CINCINNATI, OH 45207 1'-8 5/8" 12'-4 1/4" 1 19'-3" 1 7'- 83° 1 D 10" 98° 17 '-6 " 2' -6 " 23'-4 1/2" 92° 9'-7" 87° 4" 7'- 1" MIN 94° 11" 4'-9 1/8" 3° 11 12 1° 2'-1" 97° 1" '-1 17 3'-4 1/4" 4'-4 3/4" " 11 82° 97° " '-1 19 0" '-1 10 3'-8" 2 1" '-1 120° " '-2 14 90 17° ° 1 1 109° 7/8 " 97° 3/21/2016 90° 6" 3'- 4" 3/ 2'-5 0" " '-6 11'5 1 Date ISSUED FOR BID/ PERMIT 96° '-5 18 76° Description 1 14' -2" " 97° 1 No. 8'-1 1" 12 1° 1'-0" 1 0" 8'- 1° 12 104° ° 90 2'-0 " 108° 135 ° 83° A 2'-5" ISSUANCES 5" 0" ° 132 1 2 3 5 Checked By 2 3 5 IT TE Project Number 5264 I 07009 IS 1 Client Number 81 E O F OH M. J. BATTOCLETTE R EG - AT O KPN ST Drawn By EC T '-1 11 129 ° R E D A RC H M. J. BATTOCLETTE LICENSE #07009 EXPIRATION DATE 12/31/2017 2 A102 REFLECTED CEILING PLAN - CLOUDS AND SOFFIT LOCATIONS 1/8" = 1'-0" 1 A102 LEVEL 1 - Ceiling Plan- OVERALL 3/16" = 1'-0" A102 3/21/2016 7:49:41 PM LEVEL 1 REFLECTED CEILING PLANS 720 E Pete Rose Way #140 Cincinnati, OH 45202 T 513.241.4474 F 513.241.0081 Sim 5 7 A105 A103 thinkchamplin.com PROJECTION SCREEN 10'-8" POCKET 10'-0" CEILING 9'-4" CLOUD 7 A105 1 A105 2 A105 START PATTERN WITH A FULL WIDTH BOARD LINEAR PLANK AND ACOUTICAL FELT SYSTEM FULL HEIGHT FROM FLOOR TO TOP OF SOFFIT. SEE TYPICAL DETAIL 1/A105 7 A103 6 SECTION - AT STAGE WALL 3/8" = 1'-0" A103 ELEVATION - STAGE WALL 3/8" = 1'-0" HARDWOOD TRIM ON HM BORROWED LITE FRAME. SEE DETAILS SHEET A104. 3 A104 ALIGN WITH EXISTING GALLAGHER CENTER STUDENT CENTER RENOVATION PAINT DRYWALL SOFFIT TO MATCH EXISTING WOOD PANELING AND TRIM. SEE DETAILS SHEET A104. REINISTALL EXISTING WALLCOVERING ALIGN WITH EXISTING XAVIER UNIVERSITY 3800 VICTORY PKWY CINCINNATI, OH 45207 ISSUANCES No. Description Date 1 ISSUED FOR BID/ PERMIT 3/21/2016 EXISTING WALLCOVERING , REINSTALLED 5 A103 4 ELEVATION- ENTRY 3/8" = 1'-0" A103 ELEVATION- BORROWED LITE 3/8" = 1'-0" EXST COLUMN FURRING VIF ST Checked By Client Number 81 1 A104 07009 TE Project Number 5264 IT - R E D A RC INTERIOR ELEVATIONS 2 A104 A103 ENLARGED PLAN - PARTIAL GLASS COLUMN 1/2" = 1'-0" 2 A103 ENLARGED PLAN - TYPICAL GLASS COLUMN 1/2" = 1'-0" H M. J. BATTOCLETTE LICENSE #07009 EXPIRATION DATE 12/31/2017 1 3 I M. J. BATTOCLETTE A103 A104 2 Sim E O F OH 1 A103 ELEVATION - GLASS COLUMN 1/2" = 1'-0" A103 3/21/2016 7:49:48 PM 1 EXST COLUMN FURRING VIF VIF EXST COLUMN FURRING 1 A104 2 IS 1 A104 KPN AT R EG T B Drawn By O A VIF EC T EXST COLUMN FURRING GENERAL NOTES - WOOD TRIM A. B. THE DESIGN INTENTION IS TO MATCH THE EXISTING CORRIDOR AND BOOKSTORE WOODWORK AND TRIM APPEARANCE. MATCH EXISTING PROFILES, SIZES, MOUNTING HEIGHTS, TYPES AND STAINS. NEW CONSTRUCTION TO ALIGN IN HEIGHT AND FACE OF TRIM THAT MEET ARE TO BE FLUSH. HARDWOOD - MATCH EXISTING: CONFIRM EXISTING IS TRUE QUARTER OAK WITH FLAKE STAINED TO MATCH VENEER OR HARD MAPLE STAINED TO MATCH THE VENEER. PROVIDE SAMPLE FOR REVIEW AND APPROVAL, PRIOR TO FABRICATION. VENEER - MATCH EXISTING: CONFIRM EXISTING IS QUARTERED HEAVY FIGURED EUCALYPTUS WITH CUSTOM STAIN, AWI FINISH TR2 CATALYZED LACQUER 45 SHEEN; PARCEL/ FLICH: 4496; SUBSTRATE PER MANUFACTURER'S RECOMMENDATION. MEET ALL CODES AND REGULATIONS. PROVIDE SAMPLE FOR REVIEW AND APPROVAL, PRIOR TO FABRICATION. ATTACH WOOD TRIM TO HM FRAMING WITH STAGGERED SCREWS, COUNTERSINK AND PLUG. PROVIDE NEOPRENE OR SILICON GLAZING GASKETS AS REQUIRED. MITER WOOD CORNERS. ALL CORNER CONDITIONS TO BE HARDWOOD. DO NOT PROVIDE VENEER TRIM. CHAIR RAIL - MATCH EXISTING. PICTURE RAIL - MATCH EXISTING. C. D. E. 4 A104 5" F. G. H. I. 720 E Pete Rose Way #140 Cincinnati, OH 45202 T 513.241.4474 F 513.241.0081 W16 thinkchamplin.com KEYNOTES - WOOD TRIM 3 1/ W1 - SOLID OAK BASE ADHERED AND FASTENED TO EXISTING WALL ALIGN WITH EXISTING. W2 - RUBBER BASE, HARDWOOD CHAIR RAIL MOULDING AND HARDWOOD PICTURE RAIL MOULDING. W3 - 3/16" CLEAR SAFETY GLASS W4 - 3/16" TRANSOM GLASS W5 - 3/4" VENEER PLYWOOD W6 - HARDWOOD TRIM, UNLESS NOTED OTHERWISE. W7 - ALIGN W8 - PAINTED HM FIRE RATED FRAMING W9 - HARDWOOD BASE W10 - HARDWOOD BASE CAP W11 - 1/2" W X 1/4" D WOOD REVEAL W12 - REINSTALLED EXISTINGTEXTILE WALLCOVERING (BELOW PICTURE RAIL) W13 - LINE OF EXISTING WOOD BASE W14 - LINE OF NEW WOOD BASE AT NEW TRIM. W15 - PROVIDE BLOCKING AS REQUIRED. W16 - TYPICAL 4" WOOD BASE. SEE DETAIL 3/A103. 4" W2 W14 5" W6 W12 W10 W15 W7 W2 /4" 43 W14 W16 W10 3/4" 3 1/ W2 4" 7'-0" 3/4" 5 7/8 " W2 /4" 43 W12 W16 3/4" W3 W5 57 /8" W14 W15 W3 5 7/8 " W10 W6 W15 W16 4" W10 W10 W10 W10 1 1/2" 2 1/8" /4" 43 11 /4" 2 3/ W2 4 5/8" OPP HAND 3/A104 GALLAGHER CENTER STUDENT CENTER RENOVATION W12 " 3/4 1 1/2" CE 3/4" NT ER ED W6 WA L W14 /4" 23 NW ITH /8" 57 AL IG VIF L 4 ENTRY PLAN - 1 1/2" = 1'-0" 3 1/4" 4 3/4" 4 3/4" W2 W10 PLAN DETAIL - BORROW LITE TRIM 3" = 1'-0" XAVIER UNIVERSITY 3800 VICTORY PKWY CINCINNATI, OH 45207 ISSUANCES No. Description Date 1 ISSUED FOR BID/ PERMIT 3/21/2016 2 7/8" +/- 3 1/4" 1/2" REVEAL A104 3 1/4" 3 1/4" ANODIZED ALUMN EDGE PROTECTION TRIM FROM TOP OF BASE TO CEILING, ALL OUTSIDE CORNERS. BASIS OF DESIGN: SCHLUTER-INDEC 7/16" BACK PAINTED GLASS. SEE FINISH SCHEDULE. EXISTING COLUMN FURRING. 4" TYPICAL WOOD BASE. Checked By 8" 4" 3 1/2" 2" ATRIUM SIDE A104 TYPICAL WOOD BASE 3" = 1'-0" 1 A104 DETAIL - GLASS COLUMNS 3" = 1'-0" B PLAN DETAIL R E D A RC H M. J. BATTOCLETTE LICENSE #07009 EXPIRATION DATE 12/31/2017 ARCHITECTURAL DETAILS ANODIZED ALUMN EDGE PROTECTION TRIM FROM TOP OF BASE TO CEILING, ALL OUTSIDE CORNERS. BASIS OF DESIGN: SCHLUTER-INDEC 7/16" 2 TE Project Number 5264 LINE OF FINISHED FLOOR, COORDINATE WITH FINISH TYPE AND THICKNESS 07009 C PLAN DETAIL A104 3/21/2016 7:49:55 PM A104 SECTION - BORROW LITE W/ WOOD TRIM 3" = 1'-0" BACK PAINTED GLASS AND J CHANNEL BELOW. SEE FINISH SCHEDULE. HARDWOOD BASE WITH EASED EDGE. A SECTION DETAIL 3 Client Number 81 EC T 1/2" REVEAL 1/2" MATCH EXISTING PROFILE 6" 2" 1/2" - 8" COLUMN WOOD BASE. IS MATCH TYP ROOM BASE PROFILE 1/2" I M. J. BATTOCLETTE R EG HARDWAOOD E O F OH IT KPN AT O ANODIZED ALUMN EDGE PROTECTION TRIM FROM TOP OF BASE TO CEILING, ALL INSIDE CORNERS. BASIS OF DESIGN: SCHLUTER-JOLLY 1/2" ST Drawn By 1/4" ALUMN J CHANNEL WITH GASKET GLAZING. J NOSING CHANNEL AT TOP EDGE OF GLASS. METAL STUD FRAMING ANGLE MOLDING 6" ACOUSTICAL LAY-IN CEILING PER RCP METAL STUD FRAMING 5/8" GYP. BD., PAINTED COVE LIGHT FIXTURE. SEE ELECTRICAL DRAWINGS. COVE LIGHT FIXTURE. SEE ELECTRICAL DRAWINGS. 720 E Pete Rose Way #140 Cincinnati, OH 45202 T 513.241.4474 F 513.241.0081 METAL STUD FRAMING WALL ANGLE & SCREWS 6" ACOUSTICAL LAY-IN CEILING PER RCP 5/8" GYP. BD., PAINTED thinkchamplin.com 5/8" GYP. BD., PAINTED 4" UPTURN WD PANEL INVERTED GRID TO SUPPORT FIXTURE AND SECURE TO STUD AND TRACK INVERTED GRID TO SUPPORT FIXTURE AND SECURE TO STUD AND TRACK ACOUSTICAL LAY-IN CEILING PER RCP ANGLE MOLDING 6" ANGLE MOLDING INVERTED GRID TO SUPPORT FIXTURE AND SECURE TO STUD AND TRACK 4"UPTURN WD PANEL 1'-3" 11" 11" UNLESS NOTED OTHERWISE LINEAR CARRIER @ 24" O.C. LINEAR CARRIER @ 24" O.C. UNLESS NOTED OTHERWISE 4" LINEAR CARRIER @ 24" O.C. 3 3/4" ACOUTIC CEILING TILE A105 4" AXIOM PERIMETER TRIM 10 A105 WALL ANGLE & SCREWS LINEAR PLANK 9 SECTION DETAIL - AT WOOD CEILING 3" = 1'-0" A105 SECTION DETAIL - AT WOOD CEILING 3" = 1'-0" PROVIDE BLOCKING PER MANUFACTURER'S REQUEST 11'-0" NEW CLG 1/4" MIN PAINTED METAL TRANSITION TRIM. BASIS OF DESING: ARMSTRONG AXIOM 10'-0" NEW CLG 10'-10"+/- A.F.F. VARIES 3/4" REVEAL, TYP. PROVIDE 3-5/8" METAL STUD DIAGONAL BRACING @ 4'-0" O.C., SECURE TO STRUCTURE ABOVE. SEE PLAN TO FOR PARTITION TYPE. ASSEMBLY EXTENDS FROM TOP OF FLOOR SLAB TO UNDERSIDE OF DECK ABOVE. BRACE AS REQUIRED TO SECURE TO STRUCTURE ABOVE 5/8" PAINTED GWB 3/4" REVEAL, TYP. LINEAR PLANK SECTION DETAIL - AT ACOUSTIC CEILING TILE 3" = 1'-0" UNDERSIDE OF STRUCTURE ABOVE;V.I.F. LIGHT GAUGE METAL FRAMING 16" O.C. BRACE TO STRUCTURE ABOVE 3 3/4" LINEAR FLEECE @ ALL REVEALS 3/4" 4" 3 3/4" 10'-0" A.F.F. SUSPENDED ACOUSTICAL CEILING TILE SYSTEM. SEE RCP. ALUM. TRIM AT CEILING EDGE 2 1/2" 3" 2 3/4" 1'-0" 5/8" TYPE "X" GYPSUM BOARD OVER 3-5/8" METAL STUDS. PAINT AS INDICATED ON RCP. PROJECTION SCREEN, BEYOND GALLAGHER CENTER STUDENT CENTER RENOVATION 9'-11" +/TOP OF FRAME 9'-11" +/TOP OF FRAME ACOUSTIC CEILING 1'-0" VARIES 11 LINEAR FLEECE @ ALL REVEALS ACOUSTICAL CLG SYSTEM ACOUSTICAL CLG SYSTEM POWERED ROLLER SHADE CLOTH POWERED ROLLER SHADE CLOTH 5"X5" 2-SIDED PT ALUM PERMITER POCKET AND SUPPORT SYSTEM. BOD IS AXIOM AXP255, WITH 3" CLOSURE CLIP PAINTED TO MATCH ADJACENT CEILING. 5"X5" 2-SIDED PT ALUM PERMITER POCKET AND SUPPORT SYSTEM. BOD IS AXIOM AXP255, WITH 3" CLOSURE CLIP PAINTED TO 5/8" GYPADJACENT BD MATCH CEILING 5/8" GYP BD DRYWALL CORNER BEAD AND SEALANT DRYWALL CORNER BEAD AND SEALANT 3-5/8" MTL STUD 3-5/8" MTL STUD EXISTING EXTERIOR WALL XAVIER UNIVERSITY 3800 VICTORY PKWY CINCINNATI, OH 45207 TRIM TOP PLANK AS REQUIRED TO FIT. EXISTING EXTERIOR WALL LINEAR PLANK SYSTEM AND ACOUTICAL FELT BEYOND - PLANKS RUNNING PERPENDICULAR TO FLOOR. WALL IS TO BE COMPOSED OF FULL WIDTH PLANKS WITH STAGGERED JOINTS USING THE LONGEST LENGTHS POSSIBLE. ISSUANCES No. Description Date 1 ISSUED FOR BID/ PERMIT 3/21/2016 LINEAR PLAN SYSTEM AND ACOUTICAL FELT - PLANKS RUNNING PARALLEL TO FLOOR 8 A105 7 SECTION - SOFFIT AT FEATURE WALL 1 1/2" = 1'-0" A105 6 SECTION DETAIL - WOOD WALL TOP 1 1/2" = 1'-0" A105 5 SECTION DETAIL - MAIN CLG WINDOW SHADE DETAIL 1 1/2" = 1'-0" A105 SECTION DETAIL - HIGH CLG WINDOW SHADE DETAIL 1 1/2" = 1'-0" LED COVE LIGHT FIXTURE. SEE ELECTRICAL DRAWINGS SEE PLAN FOR PARTITION TYPE LINEAR CARRIER AND RIDGID CLIP ATTACHMENT SYSTEM PROVIDE BLOCKING IN WALL AS REQUIRED BY MANUFACTURER, TYPICAL SEE PLAN FOR PARTITION TYP 4" +/- Checked By 2" 1' - 4 1/2" 1/4" GAP SUSPENDED ACOUSTICAL CEILING REFL. CEILING PLANS 3/4" A105 3 A105 SECTION - RECESSED CEILING PROJECTION SCREEN 1 1/2" = 1'-0" LINEAR PLAN SYSTEM AND ACOUTICAL FELT - PLANKS RUNNING PARALLEL TO FLOOR LINEAR FLEECE AT ALL REVEALS BLOCKING AT CLIPS WALL ANGLE & SCREWS SEE PLAN FOR WALL TYPE LINEAR PLANK SYSTEM AND ACOUTICAL FELT - PLANKS RUNNING PERPENDICULAR TO FLOOR. WALL IS TO BE COMPOSED OF FULL WIDTH PLANKS WITH STAGGERED JOINTS USING THE LONGEST LENGTHS POSSIBLE. FRONT OF PROJECTOR SCREEN SECTION - TYPICAL CEILING TRANSITION 1 1/2" = 1'-0" Client Number 81 2" WOOD FACIA BY CEILING MANUFACTURER, SET BEHIND MAIN PLANK 3 3/4" PAINT EXPOSED HOUSING TO MATCH CEILING 4 - 2 A105 PLAN DETAIL - WOOD WALL 3" = 1'-0" 1 A105 SECTION DETAIL - TYICAL WOOD WALL 3" = 1'-0" M. J. BATTOCLETTE 07009 TE Project Number 5264 I R E D A RC H M. J. BATTOCLETTE LICENSE #07009 EXPIRATION DATE 12/31/2017 ARCHITECTURAL DETAILS A105 3/21/2016 7:50:10 PM VIBRATION ISOLATION HANGERS - (4) REQUIRED ONE AT EACH CORNER 3/4" NON-COMM PLYWOOD SEE A/V CONTRACTOR FOR SIZE KPN E O F OH EC T LINEAR CARRIER, TYP AT IT ELECTRICALLY OPERATED PROJECTOR SCREEN Drawn By ST VIBRATION ISOLATION HANGERS AS REQ'D CONTINUOUS FULL LENGTH OF PROJECTOR CASE PLUS TWO FEET 3" REFER TO REFLECTED CEILING PLAN SEE CLG PLAN FINISHED FLOOR RIDGID ATTACHMENT CLIP IS ACOUSTICAL CEILING GRID SYSTEM LINEAR PLANK 1/4" GAP R EG AXIOM PERIMETER TRANSITION TRIM SYSTEM, REFER TO REFLECTED CEILING PLAN. MECHANICALLY FASTEN TRIM TO CEILING GRID SYSTEM PROVIDE 18 GA. METAL STUD FRAMING ANCHORED TO UNDERSIDE OF STRUCTURE ABOVE 16" C/C FULL LENGTH OF PROJECTOR CASE PLUS TWO FEET 2 1/2" O ACOUSTICAL CEILING GRID SYSTEM 45 DEGREE METAL STUD BRACING AT 16" C/C SECURE TO UNDERSIDE OF EXIST. STRUCTURE ABOVE. 45 DEGREE METAL STUD BRACING AT 16" C/C SECURE TO UNDERSIDE OF EXIST. STRUCTURE ABOVE. 5 3/4" HANGER WIRE AS SPECIFIED FOR SUSPENDED CEILING GRID SYSTEM; SECURE TO STRUCTURE ABOVE 2" TYP WALL MOUNTED POWERED SHADE BRACKETS AND ANGLES ATTACHED TO CURTAIN WALL PER MANUFACTURERE'S INSTALLATION REQUIREMENTS. STANDARD SQUARE FASCIA PAINTED TO MATCH CURTAIN WALL. SINGLE SHADE - SEE FINISH NOTES. 720 E Pete Rose Way #140 Cincinnati, OH 45202 T 513.241.4474 F 513.241.0081 4'-5" 6'-6" 4'-5" V.I.F. V.I.F. V.I.F. V.I.F. V.I.F. 8" 12'-4" thinkchamplin.com SHADECLOTH IS CENTERED ON MULLIONS 15'-4" V.I.F. 2 A106 ELEVATION - THIRD FLOOR LOUNGE 3/8" = 1'-0" GALLAGHER CENTER STUDENT CENTER RENOVATION STUDENT LOUNGE 308 XAVIER UNIVERSITY 3800 VICTORY PKWY CINCINNATI, OH 45207 ISSUANCES m Si 2 No. Description Date 1 ISSUED FOR BID/ PERMIT 3/21/2016 A106 A106 m Si 2 A106 im 2 S Checked By EC T IT TE Project Number 5264 I 07009 IS Client Number 81 E O F OH M. J. BATTOCLETTE R EG - AT O KPN ST Drawn By R E D A RC H M. J. BATTOCLETTE LICENSE #07009 EXPIRATION DATE 12/31/2017 1 A106 PARTIAL FLOOR PLAN - LEVEL 3 3/8" = 1'-0" A106 3/21/2016 7:50:18 PM THIRD FLOOR SHADE DETAILS DOOR SCHEDULE ROOM TO ROOM NAME DOOR NUMBER DOOR HEIGHT MATERIAL WIDTH TYPE FRAME TYPE MATERIAL THK. DETAIL HEAD JAMB 110 STUDENT LOUNGE 6' - 0" 7' - 0" WD FP 0' - 2" 2 HM * * 110A 110B 110C ST1-Ca ST1-Cb STOR STOR STOR STAIR C STAIR C 6' - 0" 6' - 0" 4' - 0" 3' - 0" 3' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" WD WD WD EXST EXST F F F EXST EXST 0' - 2" 0' - 2" 0' - 2" 0' - 2" 0' - 2" 1 1 1 EXST EXST HM HM HM HM HM 1 1 1 2 2 2 FIRE RATING HARDWARE 3/4-HR 3 1-HR 1-HR 2 2 1 4 5 COMMENTS *SEE DETAILS; PAINT FRAME TO MATCH WD TRIM; DOOR IS COMPONENT OF ATRIUM LIFE SAFETY CLOSURE SYSTEM; PROVIDE ASTRGAL DOOR PROTECTION PANEL DOOR PROTECTION PANEL DOOR PROTECTION PANEL MODIFY EXISTING RATED HARDWARE MODIFY EXISTING HARDWARE BORROWED LITES 110C - HM / FRAME TYPE 3/ FIRE RATING = 3/4-HOUR / SEE BORROWED LITE DETAILS THIS SHEET. REMARK: PROVIDE RATED HM FRAME. GLASS FIRE PROTECTION PROVIDED BY DELUGE SPRINKLERS - SEE FIRE PROTECTION DRAWINGS. PROVIDE GLASS STOPS AND GASKETS TO MEET CODE LOAD AND RATING REQUIREMENTS. 720 E Pete Rose Way #140 Cincinnati, OH 45202 T 513.241.4474 F 513.241.0081 HARDWARE SETS thinkchamplin.com GENERAL NOTES SEE FINISH AND MATERIAL SCHEDULE. HARDWARE FINISH TO MATCH EXISTING BOOKSTORE HARDWARE FINISH. MATCH EXISTING BUILDING DOOR HARDWARE TYPES AND MANUFACTURERS FOR LIKE APPLICATIONS. TRANSOM GLASS HARDWARE SET 1 (INTERIOR STORAGE) 3 HEAVY DUTY HINGES 1 STOREROOM LOCKSET (SCHLAGE: D 80 PD) 1 WALL STOP 1 CYLINDER RIGID VINYL WALL PROTECTION, BOTH SIDES DOOR (SEE MATERIAL AND FINISH SCHEDULE) RIGID VINYL DOOR EDGE PROTECTION (SEE MATERIAL AND FINISH SCHEDULE) MATCH EXISTING BOOKSTORE PATTERN. PROVIDE SAMPLE TO OWNER FOR APPROVAL. HARDWARE SET 2 (INTERIOR PAIR, STEERAGE WITH ONE INACTIVE LEAF) 3 HEAVY DUTY HINGES 1 STOREROOM LOCKSET (SCHLAGE: D 80 PD) 2 FLUSH BOLTS 1 DUSTPROOF STRIKE 2 OVERHEAD STOPS 1 CYLINDER RIGID VINYL WALL PROTECTION, BOTH SIDES DOOR (SEE MATERIAL AND FINISH SCHEDULE) RIGID VINYL DOOR EDGE PROTECTION (SEE MATERIAL AND FINISH SCHEDULE) HARDWARE SET 3 (INTERIOR PAIR – ENTRY, RATED) 3 EXTRA HEAVY DUTY HINGES 1 SET AUTO FLUSH BOLTS 1 EA DUSTPROOF STRIKE 2 EA CLOSERS 1 COORDINATOR WITH FILLER AND BRACKETS 1 SET SMOKE GASKETS/ SEALS 1 ASTRAGAL 1 CLASSROOM LOCKSET (SCHLAGE: D70 PD) 1 CYLINDER 1 ELCTRIFIED WALL MAGNETIC HOLD OPENS - SEE ELECTRICAL SPECIFICATIONS POWER -- SEE ELECTRICAL DRAWINGS NOTE: MATCH EXISTING BOOKSTORE HARDWARE. DOORS TO RELEASE WITH ACTIVATION OF FIRE ALARM, SMOKE EVAC SYSTEM OR SMOKE DETECTORS. HARDWARE SET 4 (EXISTING INTERIOR STAIR) REMOVE ALARM / SOUNDER. NOTE: PROVIDE FREE ACCESS IN AND OUT OF DOOR. HARDWARE SET 5 (EXISTING EXTERIOR STAIR) REPLACE EXTERIOR GASKETS. CARD READER - MATCH EXISTING BUILDING SYSTEM. MOUNT TO BE ADA COMPLIANT. POWER SUPPLY - SEE ELECTRICAL DRAWINGS. NOTE: MODIFY EXISTING DOOR TO PROVIDE ACCESS CONTROL FOR STUDENT/ STAFF ONLY ENTRY FROM THE EXTERIOR INTO THE STAIR. COORDINATE WITH ELECTRICAL DRAWINGS AND OWNER. DOOR MUST ALWAYS ALLOW FREE OUT. 3 1/4" GL-3 3'-7" * - MATCH EXISTING VARIES SEE DOOR SCHEDULE GLASS AREA APPROX = 580 SI 3'-0" * GLASS AREA APPROX = 380 SI GL-2: TEMPERED GLASS * * * * * GLASS AREA APPROX = 3,270 SI DR PROTECTION AS SCHEDULED - C A111 3 1/4" 8" FRAME TYPE-2 WITH TRANSOM MATCH EXISING BOOKSTORE FRAME. COORDINATE WITH WOOD TRIM REQUIREMENTS. FRAME TYPE-3 WITH TRANSOM MATCH EXISING BOOKSTORE FRAME. COORDINATE WITH WOOD TRIM REQUIREMENTS. WOOD TRIM APPLIED TO SURFACE. PROFILE TO MATCH EXST BOOKSTORE DOORS. XAVIER UNIVERSITY 3800 VICTORY PKWY CINCINNATI, OH 45207 * * 7'-0" 8'-8" GL-2 GLASS AREA APPROX = 2,130SI FRAME TYPE-1 GALLAGHER CENTER STUDENT CENTER RENOVATION 2" GL-3: LAMINATE W PATTERN 7'-0" MATCH EXISTING 8'-8" 7'-0" 7'-0" 2'-4" SEE DOOR SCHEDULE 3 1/4" = 975 SI 2" MATCH EXISTING 3 1/4" GL-3: LAMINATE W PATTERN GLASS AREA APPROX 1'-1 1/2" 2" MATCH EXST 6'-0" 1'-1 1/2" 2" 3 1/4" 2" VARIES 2" SEE DOOR SCHEDULE 2" MATCH EXST 3 1/4" 6'-6 1/4" DOOR TYPE-F DOOR TYPE-FT INTERIOR FLUSH DOOR SOLID CORE FLUSH DOOR MATCH BOOKSTORE ISSUANCES No. Description Date 1 ISSUED FOR BID/ PERMIT 3/21/2016 DOOR AND FRAME TYPES 1/2" = 1'-0" CRIPPLE STUD AT CONTROL JOINT LOCATIONS. REFER TO SPECIFICATIONS. COORDINATE STUD SIZE WITH SPECS AND PARTITION SCHEDULE SECURE JAMB STUDS TO STUDS STRUCTURE ABOVE SEE WALL TYPES FLAT STRAP 2" 2" SCHEDULED GLASS 7 A111 BORROWED LIGHT SILL @ FLOOR 3" = 1'-0" 4 A111 BORROWED LIGHT JAMB 3" = 1'-0" 6 A111 BORROWED LIGHT HEAD 3" = 1'-0" 2 A111 DOOR JAMB DETAIL - #2 3" = 1'-0" Client Number 81 JAMB ANCHER (S) 1/2" 1 A111 07009 TE Project Number 5264 R E D A RC M. J. BATTOCLETTE LICENSE #07009 EXPIRATION DATE 12/31/2017 FLOOR ANCHOR 1 5/8" DOOR HEAD DETAIL - #1 3" = 1'-0" B A111 DOOR TYPICAL CONTROL JOINT DETAIL 1/2" = 1'-0" H DOOR SCHEDULE AND DETAILS HOLLOW METAL FRAME CAULK FRAME PERIMETER BOTH SIDES 2" M. J. BATTOCLETTE EC T - DOOR AS SCHEDULED HOLLOW METAL FRAME CAULK FRAME PERIMETER BOTH SIDES. ANCHORS AS SPECIFIED. SCHEDULED GLASS FRAME AS SCHEDULED METAL STUD CONTINUOUS TO TOP RUNNER METAL STUD TO HEADER 5/8" METAL STUD HEADER TYPICAL CEILING HEIGHT AS INDICATED ON CEILNG PLAN I A A111 DOOR TYPICAL TYPICAL DETAIL 1/2" = 1'-0" A111 3/21/2016 7:50:27 PM SEE WALL TYPES 2" 1 5/8" 1/2" 5/8" 2" HOLLOW METAL FRAME 2" FINISHED FLOOR 1/2" 1/2" HOLLOW METAL FRAME 5/8" CONCEALED FASTENERS 2" SCHEDULED GLASS 2" SEE WALL TYPE 1/2" 2" GYPSUM BOARD ASSEMBLIES Checked By IS GYPSUM BOARD ASSEMBLIES CONTROL JOINT. PROVIDE CONTROL JOINTS SPACED 30'-0" O.C. MAXIMUM AT CLOSEST DOOR JAMB LOCATION WITHIN MAXIMUM ALLOWED SPACING. R EG HOLLOW METAL FRAME 5/8" GYPSUM WALLBOARD (TYPE "X" WHERE SCHEDULED) ON METAL STUDS. CONTINUE STUDS, GWB, AND SOUND ATTENUATION BATTS (WHERE SCHEDULED) TO DECK U.N.O. E O F OH IT 2" 1/2" 5/8" KPN AT O LINE INDICATION OF FINISHED CEILING 5/8" GYPSUM WALLBOARD (TYPE "X" WHERE SCHEDULED) ON METAL STUDS. Drawn By RUNNERS FASTENED W/ SCREWS TO JAMB STRUT STUDS ST SEE WALL TYPE TEXTILE COMPOSITE FLOORING MANUF.: KINETEX STYLE: UMBRA (1819) COLOR: 1766 ECLIPSED SIZE: 18" X 36" BACKING: POLYESTER FELT CUSHION INSTALLATION:ASHLAR - DIRECTION FROM ENTRANCE TO SOUTH WINDOW REP: ERIN RINK: erin.rink@jjflooringgroup.com TEXTILE COMPOSITE FLOORING MANUF. KINETEX STYLE: PROPEL ( 1817) COLOR: 1708 OUTPACE SIZE: 18" X 36" BACKING: POLYESTER FELT CUSHION INSTALLATION:ASHLAR - DIRECTION FOLLOWING STRIPE DIRECTION REP: ERIN RINK: erin.rink@jjflooringgroup.com P-2 WOOD BASE DETAIL.: FINISH: SIZE: I101 " -0 WALL PAINT MANUF.: COLOR: FINISH: TC-2 WC-1 SEE SHEET A104 TO MATCH VP-1 - SUBMIT SAMPLE FOR APPROVAL 8" HT x 3/4" - SEE DETAIL 1/A104 AX-1 TC-1 WALL PAINT TO MATCH EXISTING ATRIUM VINYL WALLCOVERING - C-1 ENTRANCE ALCOVE NOTES 10, 11 STUDENT LOUNGE 110 TC-2 Align TC-2 TC-1 TC-1 TC-1 STOR 3' 0" WOOD PLANK CEILING MANUF.: ARMSTRONG STYLE: WOODWORKS PLANK SIZE: 4" PLANK - NATURAL VARIATIONS COLOR: DARK CHERRY (W1) REP: MONTY GILLESPIE: VLGillespie@armstrongceilings.com 3' 5'-3 3/4" METAL CEILING FACIA TRIM MANUF.: ARMSTRONG STYLE: AXION SIZE: 4" HEIGHT COLOR:WHITE/ GREY MATCH CEILING COLOR TC-1 110C " -0 EXISTING ELEVATOR TC-2 TC-1 Align STAIR C 1-C STOR 1'-10" STOR 110B FINISH SCHEDULE " 3'-0 0" 3'- TC-2 FLOOR BASE NORTH WALL TC-1,TC-2, VP-1,VP-2 WB-1 WB-2 P-1 EAST WALL SOUTH WALL WEST WALL P-1 P-1/GL-1 P-1/WW-1 CEILING ACT-1, ACT-2, WC-1 EXISTING SHAFT NOTES 3'-10 1/4" TC-2 TC-1 TC-1 110A TC-2 19'-7 7/8" GALLAGHER CENTER STUDENT CENTER RENOVATION NOTES 5,6,7,14,15,16,18,19 110A STORAGE TC-1 B-1 P-1,WP-1 P-1,WP-1 P-1,WP-1 P-1,WP-1 ACT-1 NOTE 8 110B STORAGE TC-1 B-1 P-1,WP-1 P-1,WP-1 P-1,WP-1 P-1,WP-1 ACT-1 NOTE 8 111 STORAGE TC-1 B-1 P-1,WP-1 P-1,WP-1 P-1,WP-1 P-1,WP-1 ACT-1 NOTE 8 C-1 B-2 - P-2 1-C STAIR C - - - EXISTING BOOKSTORE - - - 110 (ENTRANCE ALCOVE) - Align 0" 3'- FINISH LISTING 1/8" = 1'-0" 110 STUDENT CENTER NOTE 12 VP-2 0" 3'- SHERWIN WILLIAMS SW7043 WORLDLY GRAY EGGSHELL ACT-2 ACOUSTICAL CEILING TILE MANUF.: ARMSTRONG STYLE: ULTIMA 1942 BEVELED TEGULAR EDGE SIZE: 24" X 24" IN 9/16" PRELUDE SUPRAFINE GRID COLOR: WHITE TILES IN WHITE GRID AND TRIM SEE SHEET A104 TO MATCH VP-1 - SUBMIT SAMPLE FOR APPROVAL 4" HT x 3/4" - SEE DETAIL 2/A104 ROOM TC-1 TC-2 VP-1 SCH-1 VERTICAL METAL TRIM MANUF.: SCHLUTER FINISH: NATURAL ANODIZED ALUM. SIZE: SEE DRAWINGS 2 3' Align TC-1 0" 3'- WB-2 WOOD BASE DETAIL.: FINISH: SIZE: DOOR PROTECTION SHEET MANUF.: INPRO COLOR: 0545 CROWN CHERRY SUBMIT SAMPLE FOR FINAL APPROVAL SIZE: 4'-0" HT - SET ON TOP OF BASED THICKNESS: .060 INSTALLATION:SEE DRAWINGS REP: CHRIS WALSH: cwalsh@inprocorp.com ACT-1 ACOUSTICAL CEILING TILE MANUF.: ARMSTRONG STYLE: CALLA SQUARE TEGULAR SIZE: 24" X 24" IN 9/16" PRELUDE SYPRAFINE GRID COLOR: STONE *SEE NOTES 14, 15 WOOD BASE STAIN TO MATCH EXISTING WOOD BASE IN ATRIUM CORRIDOR WB-1 thinkchamplin.com 0" 3'- P-1 4" RUBBER BASE MANUF.: JOHNSONITE COLOR: #48 GRAY SIZE: 4" COVED BASE REP: ROD SEABOLT: rseabolt@CDCDIST.com B-2 6'-3 3/4" 3'-1 1/2" TC-1 VINYL PLANK RESILIENT FLOORING MANUF.: CENTIVA STYLE: CONTOUR COLOR: CP-3201-C-TK GRAPPA NOCE SIZE: 4" X 36" SURF. TEXT.: (NG) NATURAL GRAIN EDGE: SQUARE EDGE (SE) REP: MARY SIEWE: msiewe@tandus-centiva.com B-1 1'-10 3/4" 720 E Pete Rose Way #140 Cincinnati, OH 45202 T 513.241.4474 F 513.241.0081 3'-0 " WP-2 VINYL PLANK RESILIENT FLOORING MANUF.: CENTIVA STYLE: EVENT COLOR: WP-3315-E TG MAHOGONY SUBMIT SAMPLE FOR FINAL APPROVAL SIZE: 4" X 36" SURF. TEXT.: (TG) STANDARD (SE) SQ. EDGE REP: MARY SIEWE: msiewe@tandus-centiva.com VP-2 .060 WALL PROTECTION SHEET MANUF.: INPRO COLOR: TAUPE 0113 SIZE: 4'-0" HT - SET ON TOP OF 4" BASE INSTALLATION: SEE DRAWINGS REP: CHRIS WALSH: cwalsh@inprocorp.com TC-1 CARPET TO MATCH EXISTING CARPET IN ATRIUM CORRIDOR XAVIER STOCK NOTED TO BE AVAILABLE SEE XAVIER FACILITIES VP-1 WP-1 7" C-1 BACK PAINTED GLASS COLUMN PANELS MANUF.: SEE SPECIFICATIONS COLOR: SHERWIN WILLIAMS SW6537 LUXE BLUE SIZE: 1/4" TEMPERED INSTALLATION:SEE DRAWINGS & SPECIFICATIONS 4'-4 3/8" TC-2 GL-1 1'-3" TC-1 P-2 P-2 NOTE 11 NOTES 10, 11, 12 - - - - NO FINISH WORK - - - - NOTE 13 NOTE: EXTENT OF BOOKSTORE FINISH WORK IS TO BE DETERMINED BY FOLLETT CORPORATE. FINISH NOTES WORK WILL BE DONE BY TENANT, WITH THE EXCEPTION OF ALTERNATE #A01 DEMOLITION IF IT IS ACCEPTED. 1. ALL FINISHES TO BE INSTALLED PER MANUFACTURER'S DIRECTIONS. 2. ALL ACCESS PANEL DOORS, GRILLES, ETC. TO BE PAINTED TO MATCH WALL COLOR. XAVIER UNIVERSITY 3800 VICTORY PKWY CINCINNATI, OH 45207 ISSUANCES No. Description Date 1 ISSUED FOR BID/ PERMIT 3/21/2016 3. ALL HOLLOW METAL DOOR FRAMES TO BE PAINTED TO MATCH WALL COLOR. SEE SPECIFICATIONS FOR PAINT FINISH. 4. REFER TO SPECIFICATIONS SECTION 09260 FOR DRYWALL LEVEL INFORMATION. 5. PROVIDE DETAILED SEAM LAYOUT SHOP DRAWINGS FOR ALL FLOORING PATTERNS. 6. STANDARD WALL COLOR THROUGHOUT TO BE CODE "P-1", UNLESS NOTED OTHERWISE. 7. SEE ELEVATIONS SHEET FOR EAST STAGE WALL DETAILS. 8. STANDARD HT. FOR WALL PROTECTION IN ALL STORAGE ROOMS TO 4'-4" - 4'-0" WP-1 WALL PROTECTION SHEET ABOVE THE 4" RESILIENT BASE. 9. NOTIFY ARCHITECT OF ANY DISCREPANCIES BETWEEN DRAWINGS AND FIELD CONDITIONS. 10. CARPET IN NEW ALCOVE TO MATCH BOOKSTORE ALCOVE CARPET AND TO BE PULLED FROM EXISTING CAMPUS STOCK. 11. DRYWALL CEILING IN NEW ALCOVE TO BE PAINTED TO MATCH CEILING IN BOOKSTORE ALCOVE. 12. REMOVE EXISTING VINYL WALLCOVERING FROM SIDE WALL TO NEW ENTRANCE. PAINT TO MATCH VWC. 18. PROVIDE SCHLUTER SCHIENE ALUMINUM FINISH TRANSITION STRIPES BETWEEN TC-1/TC-2 TEXITLE COMPOSITE FLOORING TILES AND VP-1/VP-2 VINYL PLANK FLOORING. 19. WB-2 BASE TO BE PROVIDED AT THE 4 CENTRAL COLUMNS WITH BACK-PAINTED GLASS CLADDING ONLY. SEE DETAIL 2/A103. ST Checked By Client Number 81 Project Number 5264 I M. J. BATTOCLETTE 07009 TE IT CM E O F OH R E D A RC H M. J. BATTOCLETTE LICENSE #07009 EXPIRATION DATE 12/31/2017 INTERIOR FINISH SCHEDULE AND DETAILS I101 3/21/2016 7:51:18 PM 17. ALL FINISHES ARE PENDING PER FINAL APPROVAL OF SUBMITTED SAMPLES. CM IS 16. BASIS OF DESIGN FOR SHADES ARE MECHOSHADE SATIN WEAVE 1-2% OPEN, DIAMONWEAVE, SERIES 3000, 3200, 3300 THERMOVEIL. THIS APPLIES ALSO TO THE THIRD FLOOR LOUNGE WINDOWS DETAILED ON SHEET A1.08. I101 LEVEL 1 - Floor Finish Plan 3/16" = 1'-0" R EG 15. BEFORE CEILING INSTALLATION, A TECHNICAL REVIEW BETWEEN THE CONTRACTOR AND THE MANUFACTURER IS REQUIRED. 1 AT O 14. ALL CEILINGS NOTED ACT-1 ARE ARMSTRONG TILE COLOR STONE. PRELUDE GRID AND AXIOM TRIM FOR THESE CEILINGS ARE TO MATCH THE TILE COLOR STONE. Drawn By EC T 13. BOOKSTORE FINISH REPLACEMENT / PATCHING TO BE DETERMINED BY FOLLETT CORPORATE. LOUNGE AND EAST STAGE 720 E Pete Rose Way #140 Cincinnati, OH 45202 T 513.241.4474 F 513.241.0081 thinkchamplin.com STUDENT LOUNGE GALLAGHER CENTER STUDENT CENTER RENOVATION FOR REFERENCE ONLY - FURNITURE PLAN LAYOUT XAVIER UNIVERSITY 3800 VICTORY PKWY CINCINNATI, OH 45207 ISSUANCES No. Description Date 1 ISSUED FOR BID/ PERMIT 3/21/2016 Drawn By ST Checked By EC T IT TE R E D A RC H M. J. BATTOCLETTE LICENSE #07009 EXPIRATION DATE 12/31/2017 FOR REFERENCE STUDENT LOUNGE FURNITURE LAYOUT I102 3/21/2016 7:51:26 PM Project Number 5264 07009 IS Client Number 81 I M. J. BATTOCLETTE R EG - E O F OH O CM AT KEYED NOTES F01 F03 EXISTING TO REMAIN. EXISTING TO BE REMOVED AND RELOCATED FOR NEW CEILING. 720 E Pete Rose Way #140 Cincinnati, OH 45202 T 513.241.4474 F 513.241.0081 thinkchamplin.com MECHANICAL/ELECTRICAL ENGINEERS WWW.KLHENGRS.COM 1538 ALEXANDRIA PIKE, SUITE 11 FT. THOMAS, KENTUCKY 41075 800-354-9783 859-442-8050 859-442-8058 FAX LEXINGTON, KENTUCKY COLUMBUS, OHIO NEW YORK, NEW YORK A F03 D D D D D EX. 2-1/2" 4 D F03 D D D D D B X EXISTING FCA X X X GALLAGHER CENTER STUDENT CENTER RENOVATION X X X F01 X X X X X X C XAVIER UNIVERSITY 3800 VICTORY PKWY CINCINNATI, OH 45207 ? A.F.F. F01 F01 X X X X X ISSUANCES X No. Description Date 1 ISSUED FOR BID / PERMIT 03/21/2016 D 1 2 3 5 6 7 Drawn By KEC Checked By GRS Client Number 81 Project Number FIRE PROTECTION DEMOLITION - FIRST FLOOR 1 FD101 FD DEMOLITION - FIRST FLOOR 1/8" = 1'-0" FD101 3/18/2016 3:13:44 PM 17917 KEYED NOTES F01 F02 F04 EXISTING TO REMAIN. RECONNNECT AND RESUPPLY. PROVIDE WATER CURTAIN AT GLASS ENTRY. GENERAL NOTES A. COVERS SHALL BE CHROME / ALUMINUM IN THE STUDENT LOUNGE. COORDINATE WITH ARCHITECT PRIOR TO PURCHASING. 720 E Pete Rose Way #140 Cincinnati, OH 45202 T 513.241.4474 F 513.241.0081 thinkchamplin.com MECHANICAL/ELECTRICAL ENGINEERS WWW.KLHENGRS.COM 1538 ALEXANDRIA PIKE, SUITE 11 FT. THOMAS, KENTUCKY 41075 800-354-9783 859-442-8050 859-442-8058 FAX LEXINGTON, KENTUCKY COLUMBUS, OHIO NEW YORK, NEW YORK A 10' - 0" A.F.F. 11' - 0" A.F.F. N N 9' - 4" A.F.F. N 11' - 0" A.F.F. N N F02 F02 N N N N N F04 F02 N N 9' - 4" A.F.F. N N STUDENT LOUNGE 110 N 4N 9' - 4" A.F.F. N N N F04 N N N 9' - 4" A.F.F. N N N N F02 N N 9' - 4" A.F.F. N N F02 N N N N 9' - 4" A.F.F. B F01 N N N X N STAIR C 1-C N STOR 111 F01 STOR 110A N N N N X X N STOR 110B GALLAGHER CENTER STUDENT CENTER RENOVATION X X F01 X X X X X X X X C F01 ? A.F.F. X X X F01 XAVIER UNIVERSITY 3800 VICTORY PKWY CINCINNATI, OH 45207 X X ISSUANCES X No. Description Date 1 ISSUED FOR BID / PERMIT 03/21/2016 D 1 2 3 5 6 7 Drawn By KEC Checked By GRS Client Number 81 Project Number 17917 F-101 FP NEW - FIRST FLOOR 1/8" = 1'-0" FIRE PROTECTION NEW - FIRST FLOOR F-101 3/18/2016 3:13:40 PM 1 DEMOLITION / NEW WORK LINETYPE LEGEND = EXISTING WORK TO BE DEMOLISHED BY CONTRACTOR = NEW WORK BY CONTRACTOR = EXISTING WORK TO REMAIN KEYED NOTES M02 A 14"x12" SA 10"ø SA FP-101 14"x12" SA 12"ø SA FP-101 14"x12" SA FP-102 20"x15" SA T M02 T REMOVE EXISTING JOHNSON CONTROL THERMOSTAT AND REMOVE WIRE BACK TO VAV CONTROLLER. M02 12"x14" SA 10"x12" SA 720 E Pete Rose Way #140 Cincinnati, OH 45202 T 513.241.4474 F 513.241.0081 FP-102 20"x15" SA thinkchamplin.com 10"ø SA 4 18"x18" SA MECHANICAL/ELECTRICAL ENGINEERS WWW.KLHENGRS.COM 12"ø SA 1538 ALEXANDRIA PIKE, SUITE 11 FT. THOMAS, KENTUCKY 41075 800-354-9783 859-442-8050 859-442-8058 FAX VAV-11 LEXINGTON, KENTUCKY COLUMBUS, OHIO NEW YORK, NEW YORK 32"x14" SA 30"x14" SA 28"x18" SA 16"ø SA 16"x12" SA B VAV-11 TS 12"x12" SA 36"x14" SA 22"x14" SA M02 10"ø SA 62"x16" SA 34"x14" SA 18"x14" SA GALLAGHER CENTER STUDENT CENTER RENOVATION 12"x12" SA 12"x12" SA XAVIER UNIVERSITY 3800 VICTORY PKWY CINCINNATI, OH 45207 VAV-13 30"x10" SA T C ISSUANCES T 10"x10" SA No. Description Date 1 ISSUED FOR BID / PERMIT 03/21/2016 16"x14" SA 10"ø SA 10"ø SA FP-104 12"ø SA 20"x15" SA 10"ø SA FP-103 10"ø SA 10"ø SA 10"ø SA 10"ø SA 20"x15" SA 20"x12" SA 12"ø SA 16"x12" SA 10"x12" SA 10"ø SA 10"ø SA 24"x16" SA 12"x10" SA Drawn By CJS Checked By KTW D Client Number 81 Project Number MECHANICAL DEMOLITION - FIRST FLOOR 1 1 MD101 HD DEMOLITION - FIRST FLOOR 1/4" = 1'-0" 2 3 5 6 MD101 3/18/2016 3:13:52 PM 17917 DEMOLITION / NEW WORK LINETYPE LEGEND = EXISTING WORK TO BE DEMOLISHED BY CONTRACTOR = NEW WORK BY CONTRACTOR = EXISTING WORK TO REMAIN 4' LD (1) 2" SLOT 350 CFM 4' LD (1) 2" SLOT 350 CFM 4' LD (1) 2" SLOT 280 CFM 4' LD (1) 2" SLOT 245 CFM 4' LD (1) 2" SLOT 255 CFM 4' LD (1) 2" SLOT 255 CFM 4' LD (1) 2" SLOT 255 CFM 4' LD (1) 2" SLOT 255 CFM 4' LD (1) 2" SLOT 255 CFM M03 KEYED NOTES FP-102 A T FP-101 M03 M04 M04 M04 4' LD (1) 2" SLOT 350 CFM M04 M04 10"ø SA M01 10"ø SA 10"ø SA 14"x12" SA 10"ø SA 10"ø SA 12"x14" SA M04 FP-101 720 E Pete Rose Way #140 Cincinnati, OH 45202 T 513.241.4474 F 513.241.0081 GENERAL NOTES A. FP-102 20"x15" SA M04 STUDENT LOUNGE 110 10"ø SA 10"ø SA 4' LD (1) 2" SLOT 220 CFM CONNECT NEW DUCTWORK TO EXISTING MAIN. CUT & PATCH AS NECESSARY. INSTALL NEW SIEMENS THERMOSTAT AND INSTALL NEW WIRE BACK TO VAV CONTROLLER. RELOCATE EXISTING LINEAR DIFFUSER TO NEW LOCATION SHOWN AND BALANCE TO CFM INDICATED. PROVIDE NEW FLEX DUCT FROM MAIN TO EXISTING LINEAR DIFFUSER 10"x12" SA 4' LD (1) 2" SLOT 220 CFM 10"ø SA thinkchamplin.com ALL DIFFUSERS SHALL BE PAINTED MATCH THE CEILING COLORS. COORDINATE WITH ARCHITECTURAL PLANS. 4' LD (1) 2" SLOT 210 CFM 12"ø SA 18"x18" SA MECHANICAL/ELECTRICAL ENGINEERS 10"x10" SA 10"ø SA 4 12"ø SA 4' LD (1) 2" SLOT 220 CFM M04 M04 M04 10"ø SA 12"ø SA M01 14"x12" SA M04 10"ø SA 10"ø SA 10"ø SA M01 M01 M03 T 10"ø SA WWW.KLHENGRS.COM 1538 ALEXANDRIA PIKE, SUITE 11 FT. THOMAS, KENTUCKY 41075 800-354-9783 859-442-8050 859-442-8058 FAX VAV-12 12"ø SA 4' LD (1) 2" SLOT 220 CFM 4' LD (1) 2" SLOT 220 CFM LEXINGTON, KENTUCKY COLUMBUS, OHIO NEW YORK, NEW YORK M01 M01 32"x14" SA M01 VAV-11 10"ø SA M01 12"x12" SA M04 16"x12" SA 12x12 SR 20 CFM 4' LD (1) 2" SLOT 220 CFM STOR 110B 36"x14" SA 6"ø SA 4' LD (1) 2" SLOT 220 CFM CD-10"Ø 320 CFM 22"x14" SA B STAIR C 1-C VAV-11 M01 10"ø SA M01 M01 T 28"x18" SA M01 M03 M01 10"ø SA 6"ø SA 4' LD (1) 2" SLOT 350 CFM 10"ø SA M01 10"ø SA 12x12 SR 20 CFM 6"ø SA M01 24x24 RR 12x12 SR 20 CFM M01 EXISTING FD FD 12"ø SA 62"x16" SA VAV-14 STOR 110A 18"x14" SA 18"x14" SA M01 CD-10"Ø 320 CFM 34"x14" SA EXISTING FD FD GALLAGHER CENTER STUDENT CENTER RENOVATION CD-10"Ø 320 CFM CD-10"Ø 320 CFM XAVIER UNIVERSITY 3800 VICTORY PKWY CINCINNATI, OH 45207 CD-10"Ø 320 CFM MVD M01 78"x20" RA M03 ISSUANCES VAV-14 T FP-103 T C T No. Description Date 1 ISSUED FOR BID / PERMIT 03/21/2016 FP-104 FP-104 FP-103 Drawn By CJS Checked By KTW Client Number 81 Project Number 2 1 M-101 HV NEW - FIRST FLOOR 1/4" = 1'-0" 3 5 6 17917 MECHANICAL DUCTWORK - NEW FIRST FLOOR M-101 3/18/2016 3:13:47 PM 1 720 E Pete Rose Way #140 Cincinnati, OH 45202 T 513.241.4474 F 513.241.0081 MECHANICAL/ELECTRICAL ENGINEERS WWW.KLHENGRS.COM 1538 ALEXANDRIA PIKE, SUITE 11 FT. THOMAS, KENTUCKY 41075 800-354-9783 859-442-8050 859-442-8058 FAX HVAC VENTILATION SCHEDULE ROOMNUM ROOMNAME SYSTEM ZONE AREA CLNGHT AIR CHGS OA CHGS PEOPLE DES PEOPLE RED OA PER OA SQFT REQ SUP ACT SUP REQ OA ACT OA ACT RET ACT EXH CRITICAL PRESSURE PCT OPERABLE 109 BOOKSTORE 1 1 2121 0 0 0 20 20 7.5 0.06 1645 1680 329 336 1680 0 0.2059 E 0.0000 110 STUDENT CENTER 1 2 1761 0 0 0 20 20 7.5 0.06 1500 1530 300 306 1530 0 0.2091 E 0.0000 110A STOR 1 2 50 0 0 0 0 0 0 0.12 20 20 4 4 20 0 0.4 E 0.0000 110B STOR 1 2 66 0 0 0 0 0 0 0.12 20 20 4 4 20 0 0.5 E 0.0000 110C STUDENT CENTER 1 3 473 0 0 0 10 10 7.5 0.06 1490 1520 298 304 1520 0 0.0848 E 0.0000 110D STUDENT CENTER 1 4 475 0 0 0 15 15 7.5 0.06 1645 1680 329 336 1680 0 0.1047 E 0.0000 111 STOR 1 2 64 0 0 0 0 0 0 0.12 20 20 4 4 20 0 0.5 E 0.0000 1-C STAIR C 1 262 0 0 0 0 0 0 0 90 90 18 18 90 0 0 E 0.0000 NATURAL VENTILATION LEXINGTON, KENTUCKY COLUMBUS, OHIO NEW YORK, NEW YORK HVAC VAV BOX SCHEDULE SYSTEM STATUS SIZE MAX CFM VAV-14 NEW 14 1680 VAV-11 EXISTING 14 1590 FP-102 EXISTING 14 1520 FP-101 EXISTING 14 1680 MIN CFM HMIN CFM EAT 840 252 55 795 795 55 760 1164 55 840 1180 55 HVAC PROJECT INFO / CODE SCHEDULE LOCATION STATE TSQFT VENTILATION CODE BUILDING CODE MECHANICAL CODE PLUMBING CODE FIRE CODE ELECTRIC CODE CINCINNATI,OH OHIO 5272 2009 IMC IBC 2009 IMC 2009 IPC 2009 IFC 2009 NEC 2011 ENERGY CODE ASHRAE 90.1 2007 TOA TEX 1312 0 HVAC ACCESSORIES ACCESSORIES: 1. MOTOR DAMPER 2. ECONOMIZER 3. ROOF CURB 4. HAIL GUARDS 5. INTAKE HOOD 6. VIBRATION ISOLATION 7. FLAT FILTER 8. FILTER/MIXING BOX 9. ACCESS DOOR 10. FLEX CONNECTIONS 11. MOUNTING COLLAR 12. HOT GAS BYPASS 13. FACE/BYPASS DAMPER 14. CONDENSATE PUMP 15. MOTOR GUARD 16. GREASE TRAP 17. DUCT FLANGES 18. BASE RAIL 19. HUMIDIFIER 20. CO2 SENSORS 21. ECON POWERED EXHAUST 22. ECON BAROMETRIC RELIEF 23. HOT GAS REHEAT COIL 24. SHAFT GROUNDING BRUSHES GENERAL NOTES: KEYED NOTES: TEMP 1. S.A. S.A. 2. AI 3. AIRFLOW AO DAMPER POSITION AI AI SPACE HUMIDITY OCC. OVERRIDE AI SPACE TEMP. 4. 5. VAV BOX SCALE: NONE CENTRAL AIR TERMINAL UNITS PROVIDE SPLITTER DAMPER (SD) AT ALL MAIN BRANCH TAKEOFFS PROVIDE MANUAL VOLUME DAMPERS AT ALL BRANCH TAKEOFFS PROVIDE MINIMUM 3 TIMES STRAIGHT INLET DIAMETER TO ALL VAV TERMINAL DEVICES DAMPER NOT REQUIRED AT TERMINAL DEVICE TAKEOFF ALL MANUAL DAMPERS SHALL BE LOCATED IN AN ACCESSIBLE CEILING. PROVIDE ACCESS PANEL AS REQUIRED MVD 2. 3. 4. MVD 2. ON A CALL FOR HEAT, VAV DAMPER SHALL MODULATE DOWN TO MINIMUM SETPOINT POSITION (15% adj.). ON A CALL FOR COOLING, CONTROL VALVE SHALL CLOSE AND DAMPER SHALL MODULATE OPEN TO SATISFY ROOM TEMPERATURE. PROVIDE SUPPLY AIR TEMPERATURE SENSOR TIED TO BAS. 2. 3. 4. 5. 6. INSULATED FLEXIBLE INLET DUCT WITH MAXIMUM LENGTH OF 24" TO HARD DUCT CONNECTION TO VAV BOX VAV BOX DAMPER ACTUATOR - PROVIDE 3 FEET CLEARANCE. PROVIDE ABOVE ACCESSIBLE CEILING OR INSTALL ACCESS PANEL. GALVANIZED THREADED ROD (CONNECT TO STRUCTURE WITH DOUBLE NUT) OUTLET DUCT WRAPPED WITH INSULATION SHEET METAL DUCT INTO VAV BOX, MINIMUM LENGTH OF 3 TIMES INLET DUCT DIAMETER A. AIR FLOW 5. 6. SD 7. GALVANIZED OPERATOR PAD BRANCH MAIN DUCT DOUBLE THICKNESS TURNING VANES (TYPICAL) 3" RADIUS MINIMUM BRANCH DUCT TEE MVD MAIN BRANCH 1. GENERAL NOTES: AIR FLOW MVD MAIN BRANCH MVD KEYED NOTES: GALLAGHER CENTER STUDENT CENTER RENOVATION 20 GAUGE DOUBLE SHEET METAL AIR FOIL FULL DEPTH OF MAIN DUCT UP TO 12" WIDE BRANCHES 18 GAUGE ON WIDER BRANCHES MAIN DUCT GALVANIZED 3/16" ROD VENTLOCK NO. 600-3 DAMPER BLADE, BRACKET & LOCKING BRANCH A. VAV BOXES 1. PROVIDE LOW VOLTAGE DDC CONTROLLER, DIFFERENTIAL PRESSURE TRANSMITTER, ACTUATOR AND WIRING FOR VAV BOXES. TEMPERATURE CONTROLS CONTRACTOR SHALL FIELD OR FACTORY MOUNT CONTROLLER AT THEIR EXPENSE. VAV BOX MANUFACTURER SHALL FURNISH FLOW RING, ROUND DAMPER SHAFT FOR DIRECT MOUNTING OF ACTUATOR, AND CONTROL ENCLOSURE. TEMPERATURE CONTROLS CONTRACTOR SHALL PROVIDE TRANSFORMERS WITH CONNECTION TO LINE VOLTAGE JUNCTION BOX ABOVE CEILING PROVIDED BY ELECTRICAL CONTRACTOR IN VARIOUS LOCATIONS. PROVIDE ROOM TEMPERATURE SENSOR(S) WITH ROOM TEMPERATURE SETPOINT ADJUSTMENT CAPABILITY (+/3 DEG. F., ADJUSTABLE THRU BAS) AND OVERRIDE FEATURE (2 HOURS, ADJUSTABLE THRU BAS). 1. AIR FLOW BRANCH AI BRANCH OMIT FLEX DUCT ON DISTRIBUTION SYSTEMS THAT PENETRATE 1-HR FIRE BARRIERS. REFER TO ARCHITECTURAL PLANS FOR LOCATIONS OF FIRE BARRIERS. AIR FLOW BRANCH AIR FLOW MVD BRANCH MAIN BRANCH SD XAVIER UNIVERSITY 3800 VICTORY PKWY CINCINNATI, OH 45207 MVD No. Description Date 1 ISSUED FOR BID / PERMIT 03/21/2016 AIR FLOW SD 3. CONTROL AND MONITORING POINTS SHALL INCLUDE BUT NOT BE LIMITED TO THE FOLLOWING: a. DAMPER POSITION (AO) b. ZONE SPACE TEMPERATURE (AI) AIR FLOW c. ZONE OCCUPANCY TEMPERATURE OVERRIDE (AI) d. ACTUAL CFM (AI) 233613.00-06 e. DISCHARGE AIR TEMPERATURE (AI) VAV BOX 233300.00-01 SCALE: NONE BEAM CLAMP (MAX. WEIGHT 500 LBS.) TOP CHORD OF JOISTS. DUCT MAIN DUCT MAIN AIR FLOW MAIN BRANCH MANUAL DAMPER DETAIL SCALE: NONE TOP CHORD OF JOISTS. 2x2x16 GA. ANGLE 1/2" DIA. CONTINUOUS THREADED ROD. 1/2" CONTINUOUS THREADED ROD. METAL JOIST METAL JOIST 3/8" MACHINE BOLT 12" MIN. INSULATION 1" X 16 GA. MIN (DUCTS OVER 2 SQ. FT.) MAX. 700 LBS. 1" X 18 GA. MIN (DUCTS UNDER 2 SQ. FT.) MAX. 420 LBS. FOR DUCTS OVER 49" WIDE, TURN METAL STRAP UNDER BOTTOM OF DUCT AND FASTEN METAL STRAP MAIN SUPPLY DUCT 3-1/2" MIN. GENERAL NOTES: A. WHERE LINEAR DIFFUSER IS ADJACENT TO WINDOWS, ADJUST PATTERN CONTROLLER TO DIRECT AIRFLOW HORIZONTALLY TOWARDS WINDOWS. KEYED NOTES: 1. 2. 3. 4. 5. LOW PRESSURE SUPPLY DUCT 1" WIDE BAND AND CLAMP. SHEET METAL SCREW INSULATED FLEX. DUCT MAX LENGTH 5'-0" ABOVE ACCESSIBLE CEILINGS ONLY. PEEL BACK INSULATION AND PROVIDE STRAPPING AND SHEET METAL SCREWS AT FLEX CONNECTION TO DUCT. THEN PROVIDE STRAPPING AROUND INSULATION 233713.00-14 1. 6. 7. 8. 9. 10. 11. 12. 13. 14. SHEET METAL PLENUM 1/2" ACOUSTICAL LINING PATTERN CONTROLLER SCREWS, MIN 6" ON CENTER & SEAL AIRTIGHT, TYP, BOTH SIDES VOLUME ADJUSTER BAND CLAMP MAXIMUM SAG 1/2" PER FOOT BETWEEN SUPPORT BRACING TAKE-OFF SPIN-IN FITTING WITH ADJUSTABLE MANUAL DAMPER. LOCATE ABOVE ACCESSIBLE CEILING OR PROVIDE ACCESS PANEL BELOW DAMPER. SHEET METAL BRANCH DUCT MANUAL VOLUME DAMPER PLENUM/LINEAR DIFFUSER SCALE: NONE GENERAL NOTES: CEILING DUCTWORK SUPPORT DETAIL NOT TO SCALE MAX. SIDE INCHES THROUGH 12 13 THROUGH 30 31 THROUGH 54 55 THROUGH 84 OVER 84 233113.00-10 RECTANGULAR DUCTS MIN. GALV. SHT. GAUGE 26 (0.022 IN.) 24 (O.028 IN.) 22 (0.034 IN.) 20 (0.040 IN.) 18 (0.052 IN.) ALUMINUM MIN. B & S GAUGE 24 (0.020 IN.) 22 (0.025 IN.) 20 (0.032 IN.) 18 (0.040 IN.) 16 (0.051 IN.) DUCT SUPPORT DETAIL SCALE: NONE NOTE: DISTANCE BETWEEN DUCT HANGERS SHALL BE IN ACCORDANCE WITH THE RULES OF THE AGENCIES HAVING JURISDICTION. DUCT SIZE 36" DIA. MAX DIAMETER INCHES THROUGH 12 13 THROUGH 18 19 THROUGH 28 29 THROUGH 36 37 THROUGH 52 KEYED NOTES: MAX WEIGHT PER FOOT = 16 LBS. 1. ROUND DUCT SUPPORT DETAIL NOT TO SCALE SPIRAL SEAM ROUND DUCTS DUCT STEEL MIN. LONGITUDINAL SEAM GALV. SHT. DUCT STEEL MIN. GAUGE GALV. SHT. GAUGE 28 (0.019 IN.) 26 (0.022 IN.) 26 (0.022 IN.) 24 (0.028 IN.) 24 (0.028 IN.) 22 (0.034 IN.) 22 (0.034 IN.) 20 (0.040 IN.) 20 (0.040 IN.) 18 (0.052 IN.) FITTINGS STEEL MIN. GALV. SHT. GAUGE 26 (0.022 IN.) 24 (0.028 IN.) 22 (0.034 IN.) 20 (0.040 IN.) 18 (0.052 IN.) 2. 3. 4. 5. MAXIMUM LENGTH OF INSUL. FLEX DUCT EQUALS 5 FEET. FLEX NOT PERMITTED IN INACCESSIBLE CEILINGS INSULATED DUCT, COLLAR AND DIFFUSER BY HVAC CONTRACTOR SCOOP SPIN IN FITTING WITH MANUAL VOLUME DAMPER INTERNAL BUTTERFLY DAMPER FOR DRYWALL APPLICATIONS ONLY. (PROVIDE KEY FOR ADJUSTMENT) 6. 7. 8. 9. 233713.00-04 OMIT FLEX DUCT ON DISTRIBUTION SYSTEMS THAT PENETRATE 1-HR FIRE BARRIERS. REFER TO ARCHITECTURAL PLANS FOR LOCATIONS OF FIRE BARRIERS. SECURE TO CEILING PER MANUFACTURER'S RECOMMENDATIONS AND PER CEILING FINISH. PROVIDE GRID CLIPS PER MFG'R REQUIREMENTS. PROVIDE FRAMING FOR DRYWALL INSTALLATION. HANGER, SECURE TO STRUCTURE AND DUCTWORK PEEL BACK INSULATION AND PROVIDE STRAPPING AND SHEET METAL SCREWS AT FLEX CONNECTION TO DUCT. THEN PROVIDE STRAPPING AROUND INSULATION. SUPPORT FLEX TO PREVENT COLLAPSING DIFFUSER INSTALLATION (TYPICAL) SCALE: NONE Drawn By CJS Checked By KTW Client Number 81 Project Number 17917 MECHANICAL DETAILS M-501 ELECTRIC LEGEND SYMBOL DESCRIPTION LUMINAIRE (SEE LUMINAIRE SCHEDULE) RECESSED / SURFACE MOUNTED LUMINAIRE SURFACE OR FLUSH WALL MOUNTED LUMINAIRE 720 E Pete Rose Way #140 Cincinnati, OH 45202 T 513.241.4474 F 513.241.0081 SHADED LUMINAIRES DENOTE THOSE CONNECTED TO EMERGENCY POWER SOURCE (UNSWITCHED LUMINAIRES ARE EGRESS LIGHTS THAT OPERATE 24/7) TRACK LIGHTING IN LENGTH SHOWN AND WITH NUMBER OF LUMINAIRE HEADS AS INDICATED PROVIDE ALL REQUIRED ACCESSORIES (FITTINGS, END CAPS, POWER FEEDS, ETC.) DECORATIVE LUMINAIRE / CHANDELIER SINGLE / DOUBLE SIDED EXIT SIGN CONNECT AHEAD OF SWITCHING & CONFIGURE ARROWS TO INDICATE DIRECTION OF EGRESS TRAVEL A,B,C LUMINAIRE TYPE SWITCHING DESIGNATION a,b,c INDICATES AN EGRESS LIGHTING LUMINAIRE WIRED AHEAD OF ALL SWITCHING AND INTENDED TO PROVIDE REQUIRED EGRESS ILLUMINATION EL MECHANICAL/ELECTRICAL ENGINEERS WWW.KLHENGRS.COM 1538 ALEXANDRIA PIKE, SUITE 11 FT. THOMAS, KENTUCKY 41075 800-354-9783 859-442-8050 859-442-8058 FAX SINGLE POLE SWITCH 3 3-WAY SWITCH K KEY OPERATED SWITCH TYPE CEILING-MOUNTED OCCUPANCY SENSOR. TYPE "IR" = INFRARED, TYPE "US" = ULTRASONIC, TYPE "DT" = DUAL TECHNOLOGY TYPE WALL-MOUNTED OCCUPANCY SENSOR SWITCH. TYPE "IR"=INFRARED, TYPE "US"=ULTRASONIC, TYPE "DT"=DUAL TECH., "V"=VACANCY SENSOR, #= NUMBER OF CCTS. THAT MAY BE CONTROLLED CS LIGHTING CONTROL SYSTEM - LIGHTING CONTROL STATION LEXINGTON, KENTUCKY COLUMBUS, OHIO NEW YORK, NEW YORK DUPLEX RECEPTACLE DUPLEX RECEPTACLE - AT COUNTER HEIGHT OR SPECIAL HEIGHT - VERIFY IN FIELD DOUBLE DUPLEX ("QUAD") RECEPTACLE DOUBLE DUPLEX ("QUAD") RECEPTACLE MOUNTED AT COUNTER HEIGHT OR SPECIAL HEIGHT VERIFY IN FIELD DUPLEX GFCI RECEPTACLE - COUNTER HEIGHT OR SPECIAL HEIGHT - VERIFY IN FIELD - DO NOT FEED DOWNSTREAM OUTLETS FROM LOAD SIDE TERMINALS UNLESS SPECIFICALLY NOTED OTHERWISE ON DWGS. SPECIAL PURPOSE RECEPTACLE DETERMINE EXACT NEMA CONFIGURATION IN FIELD CASE-BY-CASE DUPLEX RECEPTACLE - SURGE PROTECTIVE DEVICE (PROVIDE DEDICATED NEUTRAL FOR EACH SPD RECEPT. BRANCH CCT. PHASE CONDUCTOR - DO NOT SHARE NEUTRALS) DOUBLE-DUPLEX ("QUAD") RECEPTACLE - SURGE PROTECTIVE DEVICE (PROVIDE DEDICATED NEUTRAL FOR EACH SPD RECEPT. BRANCH CCT. PHASE CONDUCTOR - DO NOT SHARE NEUTRALS) SPECIAL PURPOSE RECEPTACLE (MOUNT AT, ON OR WITHIN COMMUNICATION RACK/CABINET) FIELD COORDINATE WITH EQUIPMENT INSTALLER AND DETERMINE NEMA CONFIGURATION IN FIELD CEILING DUPLEX RECEPTACLE TYPE FLOOR OUTLET - POWER AND / OR TECHNOLOGY (SEE SPECIFICATIONS FOR TYPE DESIGNATION) - WHERE SHOWN AT SAME LOCATION ON DWGS. OF E & CT, THEY ARE THE SAME DIV. 26 MULTI-SERVICE FLOOR OUTLET FIRE ALARM SYSTEM MANUAL PULL STATION F S TAG GALLAGHER CENTER STUDENT CENTER RENOVATION FIRE ALARM SYSTEM SMOKE DETECTOR - PHOTOELECTRIC TYPE | TAG "IZ" = IONIZATION TYPE TAG "SB" = AUDIO SOUNDER BASE FIRE ALARM SYSTEM WALL MOUNTED DEVICES FIRE ALARM SYSTEM ELECTRO-MAGNETIC DOOR HOLDER (PROVIDE CONCEALED HEAVY-DUTY BLOCKING/ANCHORING IN WALL) F FIRE ALARM SYSTEM STROBE-ONLY UNIT (PROVIDE CANDELA RATING FOR STROBE AS INDICATED ON DRAWINGS) F FIRE ALARM SYSTEM SPEAKER/STROBE UNIT (PROVIDE CANDELA RATING FOR STROBE AS INDICATED ON DRAWINGS) THERMOSTAT T INDICATES CONNECTION TO EQUIPMENT RECESSED OR SURFACE MOUNTED PANELBOARD AS INDICATED ON PLANS TRANSFORMER T ENCLOSED CIRCUIT BREAKER IN NEMA 1 ENCLOSURE UNLESS OTHERWISE NOTED (LEFT) CIRCUIT BREAKER (CENTER) - FUSED SWITCH IN SWITCHGEAR OR DISTRIBUTION BOARD (RIGHT) XAVIER UNIVERSITY 3800 VICTORY PKWY CINCINNATI, OH 45207 INDICATES GROUNDING ELECTRODE PER NFPA 70 ARTICLE 250 MINIMUM CUSTOMER ELECTRIC METER AND ASSOCIATED CURRENT TRANSFORMER(S) AND WIRING M RECESSED OR SURFACE MOUNTED PANELBOARD AS INDICATED ON PLANS TRIANGLE SYMBOL (RIGHT) WITHIN PANELBOARD = PROVIDE WITH FEED-THROUGH OR SUB-FEED LUGS L1AA 200A MCB No. Description Date 1 ISSUED FOR BID / PERMIT 03/21/2016 SWITCHBOARD / DISTRIBUTION PANEL 200%N FLUSH IG NEMA 3R 400 PROVIDE ISOLATED GROUND BAR (LEFT) - PROVIDE 200% SIZED NEUTRAL (RIGHT) PROVIDE NEMA 3R OR OTHER INDICATED ENCLOSURE (LEFT) - PROVIDE FLUSH ENCLOSURE (RIGHT) NON-FUSED HEAVY DUTY DISCONNECT SWITCH (LEFT) AND FUSED HEAVY DUTY DISCONNECT SWITCH (RIGHT) 300 1,3 HOME RUN WITH CIRCUIT NUMBER(S) CABLING/RACEWAY, CEILING OR WALL. SEE SPECS. FOR APPLICABLE CONDUIT/RACEWAY REQ'TS. (FULLY CONCEALED IN FINISHED AREAS, CONCEALED TO OVERHEAD STRUCTURE IN UNFIN. AREAS) CONDUIT UP OR DOWN E.C. H.C. P.C. S.C. TAAC GND GFI / GFCI WP W/P WORK UNDER DIVISION 26 WORK UNDER DIVISION 23 WORK UNDER DIVISION 22 WORK UNDER DIVISION 21 TO ABOVE ACCESSIBLE CEILING GROUND GROUND FAULT CIRCUIT INTERRUPTER DEVICE (UNLESS SPECIFICALLY NOTED OTHERWISE ON DRAWINGS, DO NOT FEED DOWNSTREAM OUTLETS FROM LOAD SIDE TERMINALS OF GFI RECEPTS.) PROVIDE WEATHERPROOF EQUIPMENT/FIXTURE/DEVICE Drawn By VM FP VENDING MACHINE - PROVIDE GFCI BREAKER AK RECEPTACLE TO BE USED FOR A FLAT PANEL DISPLAY. VERIFY EXACT LOCATION AND HEIGHT OF RECEPTACLE WITH C.T.C. PRIOR TO ROUGH-IN. COMMUNICATION/INFORMATION TECHNOLOGY COORDINATE WITH SYSTEM INSTALLERS PRIOR TO INSTALLATION FOR LOCATIONS, HEIGHTS, CONDUIT TERMINATIONS, ETC. ELECTRICAL DESIGN CRITERIA 2009 OHIO BUILDING CODE 2010 INTERNATIONAL FIRE CODE 2014 NFPA 70 - NATIONAL ELECTRICAL CODE 2010 NFPA 72 - NATIONAL FIRE ALARM AND SIGNALING CODE 2009 INTERNATIONAL ENERGY CONSERVATION CODE COMMUNICATIONS OUTLET - VOICE/DATA/MISC. (PROVIDE 4"X4" OUTLET BOX WITH 1-GANG RING) PROVIDE (1) 1" CONDUIT TO ABOVE ACCESSIBLE CEILING CAVITY UNLESS NOTED OTHERWISE PR PROXIMITY READER/AUTHENTICATION DEVICE PROVIDE (1) 1" CONDUIT TO ABOVE ACCESSIBLE CEILING CAVITY UNLESS NOTED OTHERWISE PLAN-VIEW LINE TYPES WORK SHOWN BOLD-CONTINUOUS INDICATES NEW WORK (UNLESS INDICATED OTHERWISE) Checked By DTJ Client Number 81 Project Number 17917 ELECTRIC - LEGEND WORK SHOWN FADED INDICATES EXISTING WORK TO REMAIN OR NEW WORK BY OTHERS AS APPLICABLE (UNLESS INDICATED OTHERWISE) WORK SHOWN BOLD-DASHED INDICATES SELECTIVE DEMOLITION WORK (UNLESS INDICATED OTHERWISE) E-001 720 E Pete Rose Way #140 Cincinnati, OH 45202 T 513.241.4474 F 513.241.0081 MECHANICAL/ELECTRICAL ENGINEERS WWW.KLHENGRS.COM 1538 ALEXANDRIA PIKE, SUITE 11 FT. THOMAS, KENTUCKY 41075 800-354-9783 859-442-8050 859-442-8058 FAX LEXINGTON, KENTUCKY COLUMBUS, OHIO NEW YORK, NEW YORK GENERAL ADDITIONAL CONTROL: OCC.SENSOR MANUAL CONTROL STATION LAYOUT GENERAL CUSTOM 1 A/V 1 CUSTOM 2 A/V 2 CUSTOM 3 A/V 3 CUSTOM 4 ALL ON CUSTOM 5 ALL OFF DMX INPUT CUSTOM 1 ADDITIONAL CONTROL: OCC.SENSOR ZONE CONTROL TYPE LEVEL a,b,c,d,e,f,g,h,i ZONED 0-10V DIMMING 40 FC VS LUMINAIRES DMX OFF ZONE CUSTOM 2 ADDITIONAL CONTROL: OCC.SENSOR ZONE CONTROL TYPE LEVEL a,b,c ZONED 0-10V DIMMING OFF d,e,f,g,h,i ZONED 0-10V DIMMING 30 FC VS LUMINAIRES DMX OFF ZONE SYMBOL ON DRAWINGS CONTROL TYPE LEVEL c ZONED 0-10V DIMMING OFF a,b,d,e,f,g,h,i ZONED 0-10V DIMMING 20 FC VS LUMINAIRES DMX OFF LEVEL a ZONED 0-10V DIMMING OFF b,c,d,e,f,g,h,i ZONED 0-10V DIMMING 20 FC DMX OFF VS LUMINAIRES LEVEL a,b,c,d,e,f,g,h,i ZONED 0-10V DIMMING 50 FC DMX OFF VS LUMINAIRES GENERAL NOTES: CONTROL TYPE LEVEL CUSTOM PROGRAMMED SCENE AS SPECIFIED BY OWNER. COORDINATE A MEETING WITH THE OWNER TO DETERMINE FINAL PROGRAMMING REQUIREMENTS. DMX INPUT ADDITIONAL CONTROL: DMX ZONE CONTROL TYPE LEVEL SWITCHES TO CONTROL VIA THE DMX INPUT (PORTABLE CONTROLLER). SEE NOTES BELLOW. A. PROVIDE INDIVIDUAL ROOM LIGHTING CONTROLLER EQUAL TO STRAND, ALTMAN, ACUITY BRANDS NLIGHT, COOPER FIFTH LIGHT, OR LUTRON ECOSYSTEM WITH DMX AND 0-10V CONTROL CAPABILITY. A.1. LIGHTING CONTROLLER SHALL BE EASILY PROGRAMMABLE BY OWNER AFTER INSTALLATION. PROVIDE PROGRAMMABLE CONTROL STATION(S) IN LOCATION(S) SHOWN AND AS SPECIFIED ABOVE . CONTROL STATIONS SHALL BE PROVIDED WITH FIELD MODIFIABLE LABELS. COORDINATE FINAL PRESETS WITH OWNER / ENGINEER PRIOR TO INSTALLATION. A.2. PROVIDE MODULES TO CONTROL EACH ZONE (AS INDICATED ON DRAWINGS) SEPARATELY. COORDINATE DIMMING / CONTROL REQUIREMENTS WITH LUMINAIRE SCHED. A.3. PROVIDE OCCUPANCY 100% DUAL TECHNOLOGY OCCUPANCY SENSOR COVERAGE. A.4. A NETWORKED / ADDRESSABLE SYSTEM IS ACCEPTABLE IF NECESSARY FOR EASE OF COMMISSIONING. A.5. PROVIDE SUBMITTALS THAT INCLUDE DETAILED ZONE LAYOUTS, CONTROL DIAGRAMS, AND OCCUPANCY SENSOR PLACEMENT AND COVERAGES. A.6. PROVIDE (1) DMX INPUT (LOCATED IN FIELD BY OWNER) FOR PORTABLE DMX CONTROLLER OVERRIDE (CONTROLLER BY OTHERS). PROVIDE LIST / MAP OF FINAL DMX CHANNELS TO THE OWNER FOR FUTURE PROGRAMMING. 265113.00-10 Normal Panel A. Normal Lighting B. LINE VOLTAGE Utility Normal Neutral D. EXIT Emergency Lighting "Switching" Line "Sensing" Line Emergency Power Out Normal Switched Sense Normal Neutral Emergency Neutral Normal Power Sense Emergency Power In E. F CIRCUIT BREAKER AT SOURCE PANELBOARD Date ISSUED FOR BID / PERMIT 03/21/2016 FIRE 3-WAY 4-WAY 3-WAY F. ALIGN ALL DEVICES SHOWN ON PLANS AT SAME DIMENSION FROM DOOR FRAME OR WALL. CONDUIT/CABLES SHALL BE ROUTED WHEREVER NECESSARY TO KEEP DEVICES ALIGNED. ALL DEVICES MOUNTED AT SAME HEIGHT TO BE ALIGNED HORIZONTALLY. ENSURE ALL DEVICES ARE LEVEL AND PLUMB AFTER INSTALLATION. FOR MULTI-GANG DEVICES, ALIGN DEVICES AT CENTER OF GROUP. PROVIDE SINGLE FACEPLATE FOR GROUPS OF DEVICES WHERE APPLICABLE. COORDINATE WITH ALL TRADES CASE-BY-CASE. LIGHTING LOAD OR RELAY/CONTACTOR COIL AS APPLICABLE LOCAL WALL SWITCH(ES) SS LOAD CONTACT(S) OF OCCUPANCY SENSOR(S) OR RELAY PACK(S) ELCU Generator Description 1 SCALE: NONE C. Emergency Panel No. STUDENT CENTER CONTROLLER DETAILS Normal Line Automatic Transfer Switch XAVIER UNIVERSITY 3800 VICTORY PKWY CINCINNATI, OH 45207 GENERAL NOTES: On/Off Control Device (Wall Switch, Power Pack or Relay) Normal Panel GALLAGHER CENTER STUDENT CENTER RENOVATION LEVEL CUSTOM 5 ADDITIONAL CONTROL: OCC.SENSOR ALL ON ADDITIONAL CONTROL: OCC.SENSOR CONTROL TYPE CONTROL TYPE CUSTOM PROGRAMMED SCENE AS SPECIFIED BY OWNER. COORDINATE A MEETING WITH THE OWNER TO DETERMINE FINAL PROGRAMMING REQUIREMENTS. ZONE ZONE LEVEL CUSTOM 4 ADDITIONAL CONTROL: OCC.SENSOR A/V 3 ADDITIONAL CONTROL: OCC.SENSOR CONTROL TYPE CONTROL TYPE CUSTOM PROGRAMMED SCENE AS SPECIFIED BY OWNER. COORDINATE A MEETING WITH THE OWNER TO DETERMINE FINAL PROGRAMMING REQUIREMENTS. ZONE ZONE LEVEL CUSTOM 3 ADDITIONAL CONTROL: OCC.SENSOR ZONE ZONE CONTROL TYPE CUSTOM PROGRAMMED SCENE AS SPECIFIED BY OWNER. COORDINATE A MEETING WITH THE OWNER TO DETERMINE FINAL PROGRAMMING REQUIREMENTS. A/V 2 ADDITIONAL CONTROL: OCC.SENSOR CS LEVEL CUSTOM PROGRAMMED SCENE AS SPECIFIED BY OWNER. COORDINATE A MEETING WITH THE OWNER TO DETERMINE FINAL PROGRAMMING REQUIREMENTS. A/V 1 ADDITIONAL CONTROL: OCC.SENSOR PROVIDE MANUAL DIMMING CONTROLS PROVIDE SIMPLE AND LOCKABLE GRAPHICAL INTERFACE CONTROL TYPE Emergency Line Drawn By G AK Emergency Neutral Checked By GENERAL NOTES: GENERAL NOTES: A. 265100.00-04 EMERGENCY LIGHTING CONTROL UNIT SCALE: NONE B. PROVIDE EMERGENCY LIGHTING CONTROL UNIT THAT IS UL OR ETL LISTED TO UL STANDARD 924. PROVIDE CONTACTS RATED AT LEAST 20 AMPERES UP TO AT LEAST 277 VOLTS. BASIS OF DESIGN FOR THIS DETAIL IS WATTSTOPPER ELCU-200. MODIFY IF REQUIRED FOR OTHER MANUFACTURERS. BASIS OF DESIGN FOR THIS DETAIL IS WATTSTOPPER ELCU-200 SERIES. LC&D, DOUGLAS LIGHTING AND LVS CONTROLS ARE CONSIDERED EQUIVALENT. A. THIS DETAIL IS SCHEMATIC IN NATURE INTENDED TO INDICATE HOW LOCAL SWITCHING SHALL INTERACT WITH RELATED OCCUPANCY SENSORS. THERE MAY ALSO BE OTHER LIGHTING CONTROL ELEMENTS AS SHOWN ON PLAN OR IN DETAILS THAT APPLY TO A PARTICULAR AREA. DTJ Client Number 81 265100.00-13 SCHEMATIC LOCAL OVERRIDE-OFF SWITCH SCALE: NONE 260502.00-01 DEVICE ALIGNMENT DETAIL SCALE: NONE Project Number 17917 ELECTRIC - DETAILS E-501 KEYED NOTES E10 DEMOLISH DOOR EMERGENCY EXIT ALARM. 720 E Pete Rose Way #140 Cincinnati, OH 45202 T 513.241.4474 F 513.241.0081 thinkchamplin.com MECHANICAL/ELECTRICAL ENGINEERS WWW.KLHENGRS.COM 1538 ALEXANDRIA PIKE, SUITE 11 FT. THOMAS, KENTUCKY 41075 800-354-9783 859-442-8050 859-442-8058 FAX LEXINGTON, KENTUCKY COLUMBUS, OHIO NEW YORK, NEW YORK A T T 4 SR-2 SL-2 TS B EM E E10 GALLAGHER CENTER STUDENT CENTER RENOVATION TV XAVIER UNIVERSITY 3800 VICTORY PKWY CINCINNATI, OH 45207 T C T ISSUANCES No. Description Date 1 ISSUED FOR BID / PERMIT 03/21/2016 D 1 2 3 5 6 7 Drawn By AK Checked By DTJ Client Number 81 Project Number 1 ED101 ED DEMOLITION - FIRST FLOOR 1/8" = 1'-0" ELECTRIC DEMOLITION - FIRST FLOOR ED101 3/18/2016 3:13:25 PM 17917 GENERAL NOTES A. ALL EGRESS LIGHTING AND EXIT SIGNS SHALL BE WIRED AHEAD OF SWITCHING. KEYED NOTES E02 f PS5 E03 E05 PS3 i E06 E09 2 ELECTRIC LIGHTING - SECTION 1/4" = 1'-0" EL101 PROVIDE KEYED SWITCH FOR AUTHORIZED PERSONNEL TO TURN OFF "EL" EGRESS LIGHTING IN THIS ROOM. PROVIDE UL924 LISTED EMERGENCY LIGHTING CONTROL UNIT FOR SWITCH BYPASS WHEN POWER IS LOST TO FORCE EGRESS LIGHTING TO 100% ON. SEE ELCU DETAIL. PROVIDE PROGRAMMABLE CONTROL STATION FOR CONTROL OF NORMAL LIGHTING IN THIS ROOM. SEE DETAIL. MOUNT TYPE PS3 LUMINAIRES ABOVE WOOD CLOUD AS SHOWN TO ILLUMINATE CEILING AROUND CLOUD. SEE ARCHITECTURAL DRAWINGS FOR LUMINAIRE LOCAITON AND MOUNTING. TYPICAL. MOUNT TYPE PS3 LUMINAIRES TO SIDE OF WALL FURRING TO ILLUMINATE SIDE WALLS. COORDINATE EXACT MOUNTING LOCATION IN FIELD WITH ARCHITECT PRIOR TO ROUGH IN. PROVIDE NEW CORRIDOR LUMINAIRE TO MATCH EXISTING LUMINAIRES. CONNECT TO EXISTING CORRIDOR CIRCUIT AND CONTROLS. EXISTING CORRIDOR CIRCUIT IS SL2-3. 720 E Pete Rose Way #140 Cincinnati, OH 45202 T 513.241.4474 F 513.241.0081 thinkchamplin.com MECHANICAL/ELECTRICAL ENGINEERS WWW.KLHENGRS.COM 1538 ALEXANDRIA PIKE, SUITE 11 FT. THOMAS, KENTUCKY 41075 800-354-9783 859-442-8050 859-442-8058 FAX LEXINGTON, KENTUCKY COLUMBUS, OHIO NEW YORK, NEW YORK A STUDENT LOUNGE Z1 Z1 110 d d Z1 PS24 a PS24 a PS24 a Z1 d Z1 d Z1 d Z1 B Z1 Z1 d PS24 d CS DT PS24 c E-7 E - 7 EL SR5-A A3Z IR c PS24 b b PS24 PS4 E-7 EL E09 PS5 E05 f h PS3 Z1 E - 7 EL Z1 SR-2 IR A3Z SL-2 - 6 STOR 111 PS24 SL-2 SR5-A - 15 PS24 c PS24 c PS24 E02 K EM CS PS24 c PS5 f E05 SL-2 - 7 STOR 110A PS3 i E06 PS3 i E06 E VE IR A3Z c SR5-A - 16 Z1 d E-7 EX Z1 E03 STOR 110B VE b PS24 d c Z1 STAIR C 1-C d VS Z1 DT VS PS24 c d Z1 E03 SR5-A - 14 PS24 b b PS24 d Z1 d E - 7 EL PS5 f E05 E - 7 EL Z1 d DT Z1 E - 7 EL Z1 Z1 d SR5-A - 13 g b PS24 E - 7 EL Z1 g d d Z1 VS g Z1 d Z1 a PS24 g Z1 d Z1 d PS1 DT Z1 E - 7 EL a PS24 PS1 Z1 d PS24 a a PS24 PS1 DT Z1 DT d PS1 E-7 DT GALLAGHER CENTER STUDENT CENTER RENOVATION E-7 CE 2 VE SR5-A - 17 EL101 VE DT CE CE CE DT CE CE VE C E-7 E-7 DT CE XAVIER UNIVERSITY 3800 VICTORY PKWY CINCINNATI, OH 45207 CE DT CE CE CE EX DT E-7 ISSUANCES VE No. Description Date 1 ISSUED FOR BID / PERMIT 03/21/2016 D 1 2 3 5 6 7 Drawn By AK Checked By DTJ Client Number 81 Project Number 17917 1 EL101 ELECTRIC LIGHTING - NEW - FIRST FLOOR 1/8" = 1'-0" EL101 3/18/2016 3:13:28 PM ELECTRIC LIGHTING NEW - FIRST FLOOR GENERAL NOTES B. C. D. E. F. G. H. I. J. K. L. M. N. O. P. DETAILS IN COMMENTS SECTION OF LUMINAIRE SCHEDULE SHALL APPLY IN ADDITION TO CATALOG SERIES. LAMP, BALLAST AND TRANSFORMER INFORMATION IN SPECIFICATION SHALL APPLY IN ADDITION TO INFORMATION IN LUMINAIRE SCHEDULE. REFER TO DRAWINGS FOR MOUNTING TYPE, NUMBER OF FACES AND ARROWS OF EXIT SIGNS. ALL COMPACT FLUORESCENT LUMINAIRES WITH T-5 LAMPS AND SMALLER TO HAVE END-OF-LIFE CIRCUIT CUTOUT FEATURE EQUAL TO OSRAM-SYLVANIA "QUICK-SENSE". ALL 3 AND 4 LAMP PARABOLIC FLUORESCENT TROFFERS SHALL HAVE 2 BALLAST COMPARTMENTS. ALL RECESSED TROFFER HOUSINGS CONSTRUCTED WITHOUT ROLLED EDGES SHALL BE POST PAINTED. ALL RECESSED TROFFER DOOR FRAMES SHALL BE SECURED WITH SPRING LATCHES. VERIFY LUMINAIRE, LAMP AND VOLTAGE COMPATIBILITY. LAMP QUANTITY REFERS TO NUMBER OF LAMPS IN CROSS SECTION, UNLESS OTHERWISE NOTED. LENS DIMENSION REFERS TO OVERALL THICKNESS, MAXIMUM PENETRATION OF PRISM TO BE .080". THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING EACH LUMINAIRE LOCATION WITH THE ARCHITECTURAL REFLECTED CEILING PLANS AND FOR VERIFYING AND PROVIDING THE MOUNTING SYSTEM REQUIRED FOR EACH LUMINAIRE. THE CONTRACTOR ALSO PROVIDE PLASTER FRAMES, WALL BRACKETS, SUPPORTS, OR OTHER APPURTENANCES AS REQUIRED FOR PROPER INSTALLATION. CLEAN WHITE COTTON GLOVES SHALL BE WORN WHEN HANDLING THE LUMINAIRES' EXPOSED REFLECTIVE SURFACES. THE CONTRACTOR SHALL CLEAN ALL SURFACES, INCLUDING DUST, FINGERPRINTS, PAINT, ETC. WITH A CLEAN DRY CHEESECLOTH AFTER ALL INTERIOR WORK HAS BEEN COMPLETED. PLASTIC SHIPPING BAGS SHALL REMAIN ON THE LUMINAIRES UNTIL WORK IS COMPLETED. ALL LUMINAIRES HAVE A STATIC AIR FUNCTION, UNLESS OTHERWISE NOTED. ALL LUMINAIRES ARE NON-IC, UNLESS OTHERWISE NOTED. ALL LUMINAIRES ARE U.L. DAMP LISTED, UNLESS OTHERWISE NOTED. MOUNTING HEIGHTS INDICATED ARE TO THE BOTTOM OF THE LUMINAIRE, UNLESS OTHERWISE NOTED. Type Description A3Z LED PRISMATIC CE EXISTING PRISMATIC TROFFER EXIT SIGN - AC ONLY THERMOPLASTIC EX Manufacturer / Series Size Housing / Mounting LITHONIA 2TL4 4'x2'x3-3/4" DAYBRITE SPS COLUMBIA LLT24 WILLIAMS 50G METALUX 24GR EXISTING - RELOCATED FROM DEMOLITION RECESSED CHLORIDE CXL LITHONIA LQM DUAL-LITE LX SURELITES LPX WILLIAMS EXIT UNIVERSAL, REFER TO PLAN 12"x8"x2" Material STEEL THERMOPLASTIC STENCIL FACE DECORATIVE PENDANT TBD BY ARCHITECT PS3 LOW PROFILE WALL WASH OPTOLUM FINELINE LP LITHONIA LED LINEAR WAC LIGHTING OR EQUAL CSL LIGHTING MR16 (PER EXISTING DRAWINGS) OR EQUAL 1"x1/2" CONTINUOUS LENGTH ECOSENSE L35 GE AMETRIX OR EQUAL 1.5"x1.5" CONTINUOUS LENGTH SURFACE STEEL AXIS LIGHTING BEAM 4 A-LIGHT PRUDENTIAL MARK ARCHITECTURAL LIGHTING FOCAL POINT FINELITE 4'x4"x4-7/8" RECESSED FLUSH STEEL PS4 PS5 CORRIDOR LIGHT (TO MATCH EXISTING) ADJUSTABLE COVE LIGHT PS24 LINEAR FLUSH VE EXISTING - TRACK EXISTING - RELOCATED FROM DEMOLITION VS THEATRICAL TRACK LIGHTING Z1 LED DOWNLIGHT SURFACE STEEL OPAL ALUMINUM ALTMAN SMART TRACK TIMES SQUARE LIGHTING OR EQUAL PATHWAY 6VLFLX PORTFOLIO LD610 JUNO IC922LEDG3 LITEFRAME LF6LED5 0.125" MINIMUM PATTERN 12 PRISMATIC ACRYLIC LENS RECESSED PS1 RECESSED ALUMINUM Lamp Type Ballast / Driver Qty Lamp Base 1 Ballast / Driver 1 65W LED, 6400 NOMINAL 3500K, 80 CRI LUMENS 3 T8 32W 1 0W LED, WITH SIGN 0 NO BALLAST 1 LED 1 1 3.8W /FT LED, 330 LUMENS / FT 1 3500K, 80+CRI ELECTRONIC, INTEGRAL DRIVER, 0-10V DIMMABLE INTEGRAL ELECTRONIC, MVOLT, 0-10V DIMMING Finish ELECTRONIC INTEGRAL DRIVER, MVOLT WHITE ELECTRONIC TRANSFORMER Voltage FLAT STEEL DOOR FRAME, FIELD REPLACABLE LED MODULE AND DRIVER 65 VA 277 V RELOCATE FROM DEMOLITION - SEE DEMOLITION SHEET 96 VA 277 V RED LETTERS, AC ONLY 1 VA 277 V 50 VA 277 V 8 VA 277 V PROVIDE CONTINUOUS LENGTHS AS SHOWN ON DRAWINGS (2' LENGTHS HAVE BEEN DRAWN FOR SCHEMATIC PURPOSES ONLY). PROVIDE ALL NECESSARY POWER SUPPLIES AND ACCESSORIES FOR A FULLY OPERABLE SYSTEM. LUMINAIRE SHALL MATCH THE EXISTING LUMINAIRES IN SIMILAR LOCATIONS FROSTED 1 4W /FT LED, 330 LUMENS / FT 1 3500K, 80+CRI INTEGRAL ELECTRONIC, MVOLT, 0-10V DIMMING WHITE AIM IN FIELD WITH ARCHITECT, PROVIDE CONTINUOUS 8 VA LENGTHS AS SHOWN ON DRAWINGS (2' LENGTHS HAVE BEEN DRAWN FOR SCHEMATIC PURPOSES ONLY). PROVIDE ALL NECESSARY POWER SUPPLIES AND ACCESSORIES FOR A FULLY OPERABLE SYSTEM. 277 V SPOTLESS LENS 1 45W LED, 4000 LUMEN 3500K, 80+CRI INTEGRAL ELECTRONIC, MVOLT, 0-10V DIMMING WHITE VERIFY WIDTH WITH ARCHITECTURAL CEILING SLOTS 45 VA 277 V 1 PAR 30 INC 120 V 1 50W LED RGBA IQ38 RELOCATE FROM DEMOLITION - SEE DEMOLITION 75 VA SHEET PROVIDE BLACK DMX ENABLED TRACK, MOUNT TRACK 50 VA TO HIGH CEILING BETWEEN CLOUDS TO CONCEAL, PROVIDE ALL NECESSARY COMPONENTS FOR A FULLY OPERABLE SYSTEM REMOTE PHOSPHOR LENS, FIELD REPLACABLE LED MODULE AND DRIVER 277 V 1 1 WHITE Fixture Load 35W MR16 SEMI-SPECULAR REFLECTOR, MEDIUM DOWNLIGHT OPTIC GU10 WHITE Comments 1 SURFACE 6" DIAx15"x7-1/2" Lamp Qty Lens Description 1 NA 1 25W LED, 2000 LUMEN 3500K, 80 CRI 1 INTEGRAL ELECTRONIC, DMX CONTROLLED PROVIDE CUSTOM COLOR TO MATCH CEILING COORDINATE WITH ARCHITECTURAL DRAWINGS AND GET OWNER APPROVAL ELECTRONIC, INTEGRAL DRIVER, 0-10V DIMMABLE SELF TRIM 35 VA 720 E Pete Rose Way #140 Cincinnati, OH 45202 T 513.241.4474 F 513.241.0081 277 V thinkchamplin.com MECHANICAL/ELECTRICAL ENGINEERS 120 V 25 VA WWW.KLHENGRS.COM 1538 ALEXANDRIA PIKE, SUITE 11 FT. THOMAS, KENTUCKY 41075 800-354-9783 859-442-8050 859-442-8058 FAX LEXINGTON, KENTUCKY COLUMBUS, OHIO NEW YORK, NEW YORK GALLAGHER CENTER STUDENT CENTER RENOVATION Interior Lighting Compliance Certificate XAVIER UNIVERSITY 3800 VICTORY PKWY CINCINNATI, OH 45207 2009 IECC Section 1: Project Information Project Type: Alterations ISSUANCES Section 2: Interior Lighting and Power Calculation Floor Area (sq. ft.) 6,386 Watts per sq. ft. 1.2 Allowed Watts 7,663 Proposed Watts See Below Complies Yes No. Description Date 1 ISSUED FOR BID / PERMIT 03/21/2016 Section 3: Interior Lighting Fixture Schedule Type A3Z CE EXISTING 2X4 PS1 PS3 PS4 PS5 PS24 Z1 Lamp Type 65W LED, 3500K, 80 CRI T8 32W T8 32W LED 3.8W /FT LED, 3500K, 80+CRI 35W MR16 4W /FT LED, 3500K, 80+CRI 45W LED, 3500K, 80+CRI 25W LED, 3500K, 80 CRI Ballast / Driver ELECTRONIC INTEGRAL DRIVER, MVOLT ELECTRONIC ELECTRONIC ELECTRONIC, INTEGRAL DRIVER, 0-10V DIMMABLE INTEGRAL ELECTRONIC, MVOLT, 0-10V DIMMING TRANSFORMER INTEGRAL ELECTRONIC, MVOLT, 0-10V DIMMING INTEGRAL ELECTRONIC, MVOLT, 0-10V DIMMING ELECTRONIC, INTEGRAL DRIVER, 0-10V DIMMABLE Lamp Qty 1 3 3 1 1 1 1 1 1 Count 3 11 19 4 20 1 79 21 52 Load 65 VA 96 VA 96 VA 50 VA 8 VA 35 VA 8 VA 45 VA 25 VA Total Load 195 VA 1056 VA 1824 VA 200 VA 152 VA 35 VA 632 VA 945 VA 1300 VA 6339 VA Drawn By AK Checked By DTJ Client Number 81 Project Number 17917 ELECTRIC LUMINAIRE SCHEDULE EL601 3/18/2016 3:13:31 PM A. Electric Luminaire Schedule KEYED NOTES E01 E04 E07 E08 COORDINATE EXACT TECHNOLOGY POWER AND PATHWAY LOCATIONS AND REQUIREMENTS WITH OWNER / TECHNOLOGY CONTRACTOR PRIOR TO ROUGH IN. PROVIDE DARK BROWN (TO MATCH BASEBOARD) USB RECEPTACLES INSTALLED HORIZONTALLY IN THE BASEBOARD. COORDINATE EXACT LOCATION IN FIELD WITH ARCHITECT PRIOR TO ROUGH IN. PROVIDE POWER AND CONTROL FOR SHADES. COORDINATE EXACT REQUIREMENTS WITH SHADE MANUFACTURER PRIOR TO ROUGH IN. COORDINATE CONTROL SWITCH WALLS IN FIELD WITH OWNER PRIOR TO ROUGH IN. LAYOUT ALL CONTROLS IN A NEAT CLEAN LAYOUT. 720 E Pete Rose Way #140 Cincinnati, OH 45202 T 513.241.4474 F 513.241.0081 thinkchamplin.com MECHANICAL/ELECTRICAL ENGINEERS WWW.KLHENGRS.COM 1538 ALEXANDRIA PIKE, SUITE 11 FT. THOMAS, KENTUCKY 41075 800-354-9783 859-442-8050 859-442-8058 FAX LEXINGTON, KENTUCKY COLUMBUS, OHIO NEW YORK, NEW YORK A E07 T E07 J J SHADE USB SHADE USB E04 USB USB E04 E04 SR5-A - 22 FP-102 FP-101 4 STUDENT LOUNGE 110 E01 J PROJ. SR5-A - 11 PROJ SCREEN CM 75 cd SHADE J TYP OF (8) ON COLUMN USB E04 SR-2 STOR 111 T TYP OF (8) ON COLUMN USB J E07 T J E07 SHADE E04 TSR-2 15 cd E04 SL-2 LI SR5-A - 2 STAIR C 1-C SR5-A - 18 E01 110B SR5-A - 4 SR5-A - 5 SR5-A - 6 E08 DATA RACK EM VM LI VM TEM E01 75 cd PROJ. E08 SR5-A - 1 SR5-A - 24 75 cd SR5-A - 25 SR5-A - 10 SR5-A STOR VM E01 VM B E SR5-A - 7 SR5-A - 23 SR5-A - 12 PR E01 SR5-A 24 SR5-A - 19 SR5-A - 8 STOR 110A FRZ. J DOOR GALLAGHER CENTER STUDENT CENTER RENOVATION J FRZ. PROJ SCREEN SR5-A - 9 SR5-A - 28 FP SR5-A - 20 T 110 cd XAVIER UNIVERSITY 3800 VICTORY PKWY CINCINNATI, OH 45207 T C WP/GFCI T 75 cd SR5-A - 26 FP-104 B UP TO SR5-A ISSUANCES FP-103 SR5-A - 21 D No. Description Date 1 ISSUED FOR BID / PERMIT 03/21/2016 SR5-A - 27 TSR5 WP / GFCI WP / GFCI C 1 2 3 5 6 7 Drawn By AK D Checked By DTJ Client Number 81 Project Number 17917 1 EP101 ELECTRIC POWER - NEW - FIRST FLOOR 1/8" = 1'-0" 2 EP101 ELECTRIC POWER - NEW - BASEMENT 1/8" = 1'-0" 2 EP101 3/18/2016 3:13:34 PM 1 ELECTRIC POWER NEW - FIRST FLOOR 720 E Pete Rose Way #140 Cincinnati, OH 45202 T 513.241.4474 F 513.241.0081 MECHANICAL/ELECTRICAL ENGINEERS WWW.KLHENGRS.COM 1538 ALEXANDRIA PIKE, SUITE 11 FT. THOMAS, KENTUCKY 41075 800-354-9783 859-442-8050 859-442-8058 FAX LEXINGTON, KENTUCKY COLUMBUS, OHIO NEW YORK, NEW YORK GALLAGHER CENTER STUDENT CENTER RENOVATION XAVIER UNIVERSITY 3800 VICTORY PKWY CINCINNATI, OH 45207 No. Description Date 1 ISSUED FOR BID / PERMIT 03/21/2016 Drawn By AK Checked By DTJ Client Number 81 Project Number 17917 ELECTRIC SINGLE LINE DIAGRAM EP601 Panel Name: SL-2 Panel Name: E Supply From: Notes: Existing Square D CKT 1 Voltage: 480V 3PH Circuit Description Trip Poles A 1 3.1 kVA 2.6 kVA (EX) BOOKSTORE LIGHTING 20 A 3 (EX) ATRIUM LIGHTING 20 A 1 5 (EX) OFFICE LIGHTING 20 A 1 7 (#) BOOKSTORE LIGHTING 20 A 1 Phase: 3 Wire: 4 B C 2.5 kVA 2.7 kVA 1.3 kVA 2.6 kVA Supply From: Notes: Existing Square D Location: Poles 1 20 A Trip (EX) ATRIUM COVE Circuit Description CKT 2 CKT 1 1 20 A (EX) ATRIUM COVE 4 1 20 A STUDENT LOUNGE 110 LIGHTING 2.5 kVA Voltage: 480V 3PH Circuit Description Trip Poles A 1 0.4 kVA 4.9 kVA (EX) EXIT LIGHTS 20 A 3 (EX) THEATRE EM LIGHTING 20 A 1 6 5 (EX) EM LIGHTING LOWER LEVEL 20 A 1 Phase: 3 Wire: 4 B C 2.2 kVA 5.9 kVA Location: Poles Trip 3 60 A Circuit Description (EX) TEM 4 3.3 kVA 6.0 kVA 6 8 7 (#) EMERGENCY LIGHTING 20 A 1 9 10 9 (EX) EM LIGHTING LEVEL TWO 20 A 1 11 12 11 (EX) EM LIGHTING LEVEL THREE 20 A 1 13 14 13 15 16 15 17 18 17 19 20 19 20 21 22 21 22 24 23 24 26 25 26 28 27 28 30 29 30 23 25 5.0 kVA 27 2.5 kVA 3 29 60 A (EX) TSR-2 2.1 kVA Load Classification Lighting Receptacle Misc Motor Kitchen Equipment Water Heater Connected Load 4938 VA 0 VA 0 VA 0 VA 0 VA 0 VA Total Connected Load: 13.2 kVA Demand Factor 125.00% 0.00% 0.00% 0.00% 0.00% 0.00% 6.0 kVA Estimated Demand 6173 VA 0 VA 0 VA 0 VA 0 VA 0 VA 2.2 kVA 1.5 kVA 1 20 A (EX) 8 1 20 A (EX) 10 2.6 kVA 12 2.0 kVA (EX) B LEVEL/ XMFR AISLE LTG. 20 A 1 14 2.0 kVA 2.0 kVA 3 20 A (EX) SMOKE EXHAUST 2.0 kVA 7.7 kVA Existing Loads Existing Connected Load 21745 VA Existing Load Demand Factor 100.00% Existing Load Demand 21745 VA 0.5 kVA 1.5 kVA CKT 2 Load Classification Lighting Receptacle Misc Motor Kitchen Equipment Water Heater Connected Load 492 VA 0 VA 0 VA 0 VA 0 VA 0 VA Total Connected Load: 9.3 kVA Demand Factor 125.00% 0.00% 0.00% 0.00% 0.00% 0.00% 16 18 14.0 kVA Estimated Demand 615 VA 0 VA 0 VA 0 VA 0 VA 0 VA 720 E Pete Rose Way #140 Cincinnati, OH 45202 T 513.241.4474 F 513.241.0081 thinkchamplin.com 15.8 kVA Existing Loads Existing Connected Load 38542 VA Existing Load Demand Factor 100.00% Existing Load Demand 38542 VA MECHANICAL/ELECTRICAL ENGINEERS WWW.KLHENGRS.COM Panel Totals Total Connected Load: 26.9 kVA Panel Totals Total Connected Load: 39.0 kVA Total Estimated Demand: 28118 VA Total Estimated Demand Amps: 1538 ALEXANDRIA PIKE, SUITE 11 FT. THOMAS, KENTUCKY 41075 800-354-9783 859-442-8050 859-442-8058 FAX Total Estimated Demand: 39157 VA 34 A Total Estimated Demand Amps: 47 A LEXINGTON, KENTUCKY COLUMBUS, OHIO NEW YORK, NEW YORK Panel Name: SR-2 Panel Name: EM Supply From: TSR-2 Notes: Existing Square D CKT 1 Voltage: 208V 3PH Circuit Description Trip Poles A 1 1.1 kVA 0.9 kVA (EX) BOOKSTORE RECEPTACLES 20 A 3 (#) Spare 20 A 5 (#) Spare 20 A 1 7 (EX) OFFICE RECEPTACLES 20 A 1 9 (EX) OFFICE RECEPTACLES 20 A 1 11 (EX) OFFICE - WELCOME DESK... 20 A 1 13 (EX) DETAIL 114 LIGHTING 20 A 1 15 (EX) ATRIUM WALL SCONCES 20 A 1 17 (EX) INFO COUNTER LIGHTING 20 A 1 19 (EX) SIGNAL PROCESSOR 20 A 1 21 (EX) BIG FRIDGE (COFFEE SHOP) 20 A 1 23 (EX) COFFEE MACHINE 20 A 1 25 (EX) COFFEE MACHINE 20 A 1 27 (EX) MARQUIS SIGN 20 A 1 29 (EX) VENDING RECEPTACLES 20 A 1 31 (EX) GAS VALVE FIREPLACE 20 A 1 33 (EX) CAP. MACHINE 30 A 1 35 (EX) CAP. MACHINE 20 A 1 37 (EX) CONTROL KEEPER / LIGHT SYSTEM 20 A 1 39 (EX) PHONE BOARD 20 A 1 41 (EX) ENERGY MGMT. / HVAC SYSTEM 20 A 1 Load Classification Lighting Receptacle Misc Motor Kitchen Equipment Water Heater Connected Load 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 1 Phase: 3 Wire: 4 B C 0.0 kVA 0.5 kVA 0.0 kVA 0.0 kVA 1.1 kVA 0.5 kVA 1.1 kVA 0.0 kVA 1.1 kVA 0.5 kVA 0.7 kVA 0.7 kVA 0.6 kVA 0.4 kVA 0.5 kVA 0.0 kVA 0.0 kVA 0.0 kVA 0.0 kVA 0.0 kVA 0.0 kVA 0.0 kVA 0.0 kVA 0.0 kVA 0.0 kVA 0.0 kVA 0.0 kVA 0.0 kVA 0.0 kVA 0.0 kVA 0.0 kVA 0.0 kVA 0.0 kVA 0.0 kVA 0.0 kVA 0.0 kVA 0.0 kVA 0.0 kVA 0.0 kVA 0.0 kVA Total Connected Load: 5.0 kVA Demand Factor 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% Supply From: TEM Notes: Existing Square D Location: Poles 1 20 A Trip (EX) ATRIUM RECEPTACLES Circuit Description CKT 2 CKT 1 1 20 A (EX) ATRIUM RECEPTACLES 4 1 20 A (#) Spare 1 20 A (EX) COFFEE/ COOLERS 1 20 A (EX) VENDING RECEPTACLES 1 20 A (EX)RECEPTACLES Circuit Description Trip Poles A 1 0.5 kVA 2.9 kVA (EX) ELEVATOR SUMP 20 A 3 (EX) AHU-1 SUMP 20 A 1 6 5 (EX) ORCHESTRA PIT SUMP / WHEELCHAIR... 20 A 1 8 7 (EX) THEATRE EGRESS 20 A 1 10 9 (EX) FACP 20 A 1 12 11 (EX) FACP 20 A 1 1 20 A (EX) RECEPTACLES 14 13 (EX) ELEVATOR CAB LIGHTING 20 A 1 1 20 A (EX) CYBERCAFE 16 15 (EX) ACCESS CONTROL - 1ST 20 A 1 2 20 A (EX) VICTORY PERK 18 17 20 19 (EX) GENERATOR BATTERY CHARGER 20 A 1 Phase: 3 Wire: 4 B C 1.1 kVA 2.9 kVA Location: Poles Trip Circuit Description 3 30 A (EX) EMERGENCY DIMMERS 4 1 20 A (EX) RECEPTACLES 8 1.1 kVA 2.9 kVA 0.3 kVA 0.0 kVA CKT 2 6 0.5 kVA 10 0.5 kVA 0.5 kVA 0.5 kVA 0.5 kVA 0.5 kVA 0.5 kVA 0.5 kVA 1 20 A (EX) ACCESS CONTROL 12 1 20 A (EX) PUB 14 1 20 A (EX) PUB 16 1 20 A (EX) CLOCK TOWER PANEL 18 0.2 kVA 20 1 20 A (EX) UNDERCOUNTER RECEPTACLES 22 21 (EX) GENERATOR HEAT STRIP 20 A 1 1 20 A (EX) UNDERCOUNTER RECEPTACLES 24 23 (EX) SPARE TOWARDS GENERATOR 20 A 1 1 20 A (EX) 26 25 26 2 20 A (EX) CYBERCAFE 28 27 28 30 29 30 1 20 A (EX) 32 31 32 1 20 A (EX) SECURITY SYSTEM 34 33 34 1 20 A (EX) SOUND SYSTEM 36 35 36 0.4 kVA 22 0.5 kVA 24 1 20 A (EX) CONTROL BOOTH / TRACK LIGHTING 38 37 38 1 20 A (EX) CONTROL BOOTH / VICTOR PERK 40 39 40 1 20 A (EX) ICE CREAM MACHINE 42 41 42 2.5 kVA 2.1 kVA Estimated Demand 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA Existing Loads Existing Connected Load 9555 VA Existing Load Demand Factor 100.00% Existing Load Demand 9555 VA Load Classification Lighting Receptacle Misc Motor Kitchen Equipment Water Heater Panel Totals Total Connected Load: 9.6 kVA Connected Load 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA Total Connected Load: 4.9 kVA Demand Factor 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 6.0 kVA Estimated Demand 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA Existing Loads Existing Connected Load 16810 VA Existing Load Demand Factor 100.00% Existing Load Demand 16810 VA XAVIER UNIVERSITY 3800 VICTORY PKWY CINCINNATI, OH 45207 Total Estimated Demand: 16810 VA 27 A GALLAGHER CENTER STUDENT CENTER RENOVATION 5.9 kVA Panel Totals Total Connected Load: 16.8 kVA Total Estimated Demand: 9555 VA Total Estimated Demand Amps: Voltage: 208V 3PH Total Estimated Demand Amps: 47 A ISSUANCES Panel Name: SR5-A CKT 1 Voltage: 208V 3PH Circuit Description Trip USB RECEPTACLES - STUDENT LOUNGE 110 20 A 3 Misc - Projectors - STUDENT LOUNGE 110 20 A 1 5 (G)VM 20 A 1 7 (G)VM 20 A 1 9 (G) FREEZER 20 A 1 11 RECEPTACLE - ROOM 110A, 110, 111 20 A 1 13 THEATRE LIGHTING - STUDENT LOUNGE 110 20 A 1 15 THEATRE LIGHTING - STUDENT LOUNGE 110 20 A 1 17 TRACK LIGHTING - TECHNOLOGY CENTER 20 A 1 19 Receptacle STUDENT LOUNGE 110 20 A 1 21 Receptacle Outside 20 A 1 23 Receptacle STOR 110A - RACK 20 A 1 25 Misc STUDENT LOUNGE 110 - SHADES 20 A 1 27 Receptacle Outside 20 A 1 29 Spare 20 A 1 31 Spare 20 A 1 33 Spare 20 A 1 35 Spare 20 A 1 37 Spare 20 A 1 39 Spare 20 A 1 41 Spare 20 A 1 Load Classification Receptacle Motor Lighting Misc Poles A 1 1.4 kVA 1.4 kVA Phase: 3 Wire: 4 B C 0.8 kVA 0.8 kVA 0.8 kVA 0.8 kVA 0.8 kVA 0.8 kVA 0.8 kVA 0.7 kVA 0.7 kVA 0.7 kVA 0.8 kVA 0.8 kVA 0.8 kVA 1.9 kVA 1.5 kVA 1.2 kVA 0.4 kVA 0.4 kVA 0.4 kVA 0.2 kVA 0.4 kVA 0.3 kVA 0.5 kVA 0.7 kVA 0.4 kVA 0.3 kVA 0.0 kVA 0.0 kVA 0.0 kVA 0.0 kVA 0.0 kVA 0.0 kVA 0.0 kVA 0.0 kVA 0.0 kVA 0.0 kVA 0.0 kVA 0.0 kVA 0.0 kVA 0.0 kVA Total Connected Load: 7.9 kVA Connected Load Demand Factor 7020 VA 100.00% 1600 VA 112.50% 5688 VA 125.00% 7020 VA 100.00% 7.0 kVA Total Estimated Demand: 22.9 kVA Total Estimated Demand Amps: 63.7 A Poles 1 Trip Circuit Description 20 A USB RECEPTACLES - STUDENT LOUNGE 110 1 20 A (G)VM 4 1 20 A (G)VM 6 No. Description Date 1 ISSUED FOR BID / PERMIT 03/21/2016 CKT 2 1 20 A (G)FREEZER 8 1 20 A RECEPTACLES - STUDENT LOUNGE 110 10 1 20 A RECEPTACLES - STUDENT LOUNGE 110 12 1 20 A THEATRE LIGHTING - STUDENT LOUNGE 110 14 1 20 A TRACK LIGHTING - TECHNOLOGY CENTER 16 1 20 A Misc STOR 110A - RACK 18 1 20 A Receptacle Outside 20 1 20 A RECEPTACLES - STUDENT LOUNGE 110 22 1 20 A Misc STUDENT LOUNGE 110 - SCREEN 24 1 20 A Misc - Data Rack 26 1 20 A Misc FP 28 1 20 A Spare 30 1 20 A Spare 32 1 20 A Spare 34 1 20 A Spare 36 1 20 A Spare 38 1 20 A Spare 40 1 20 A Spare 42 6.4 kVA Estimated Demand 7020 VA 1800 VA 7109 VA 7020 VA Panel Totals Total Connected Load: 21.3 kVA Location: STUDENT LOUNGE 110 Additional Notes: Drawn By AK Checked By PANEL SCHEDULE LEGEND (EX) (#) (G) (GE) (ST) (A) (L) (LT) (->) = = = = = = = = = EXISTING CIRCUIT TO REMAIN NEW CIRCUIT TO EXISTING CIRCUIT BREAKER PROVIDE GROUND-FAULT CIRCUIT INTERRUPTER (GFCI) CIRCUIT BREAKER PROVIDE GROUND-FAULT EQUIPMENT PROTECTION (GFEP) CIRCUIT BREAKER PROVIDE SHUNT TRIP CIRCUIT BREAKER PROVIDE ARC FAULT CIRCUIT INTERRUPTER (AFCI) CIRCUIT BREAKER PROVIDE LOCK-ON DEVICE PROVIDE LOCK-OUT/TAG-OUT DEVICE CONNECT BRANCH CIRCUIT, WHICH WAS DISCONNECTED FROM ANOTHER SOURCE AS PART OF SELECTIVE DEMOLITION, TO POLE SPACE(S) AND BREAKER INDICATED, DETERMINE EXACT POLE ASSIGNMENT(S) BASED ON EXISTING COLOR-CODING OF THE BRANCH CIRCUIT CONDUCTOR INSULATION PANEL SCHEDULE GENERAL NOTES A. B. C. PROVIDE HACR RATED BREAKERS ON ALL MOTOR LOADS. PROVIDE LOCKING TYPE BREAKER FOR ALL LIFE SAFETY AND NIGHT LIGHTING BRANCH CIRCUITS. UNLESS INDICATED OTHERWISE ON PLANS OR SCHEDULES, PROVIDE NEW BRANCH OVERCURRENT PROTECTIVE DEVICE (OPD) BREAKER OR FUSED SWITCH, WITH FUSE, AS APPLICABLE) IN CASES WHERE NEW CIRCUITS OR FEEDERS ARE SHOWN CONNECTED TO EXISTING POWER DISTRIBUTION EQUIPMENT. PROVIDE OPD MANUFACTURED BY THE SAME MANUFACTURER AS THE EXISTING EQUIPMENT IN WHICH IT WILL BE INSTALLED. PROVIDE A.I.C. RATINGS THAT MEET OR EXCEED THE RATINGS OF THE EXISTING EQUIPMENT AND OPD's. DTJ Client Number 81 Project Number 17917 ELECTRIC PANEL SCHEDULES EP602 3/18/2016 3:13:36 PM Supply From: TSR5 Notes: New