Runway and Taxiway Inset Lights IRGL-LED, L852G Inset Runway Guard Light-LED Compliances: FAA AC 150/5345-46: 852G FAA Engineering Brief 67 12˝ Fixture Shown Applications Ordering Information Inset Runway Guard Lights are a series of alternate-flashing yellow, unidirectional inset lighting fixtures (L-852G) equally spaced along a runway holding position marking that are only visible to aircraft approaching the hold position from the taxiway side of the fixture. These unidirectional lights are designed for use in all weather conditions in autonomous mode. Features ETL Certified Low energy consumption Luxeon LEDs Long life LED technology, rated at 50,000h L70, reduces maintenance costs. Low profile, <.5˝ (13 mm) – FAA Style 2 Operates on either 3 or 5 step ferroresonant CCRs Easy to maintain – no sealant required for prism or feed-through assembly replacement Pressure test plug for seal integrity verification Can be retrofitted on existing installations where Logitrac® Control Devices are available. Requires the addition of a second L-823 plug. The autonomous version features an internal circuitry that eliminates the need for synchronizing Local Control Devices. Fixture connects directly into isolation transformer. A simple, separate Remote Programming Tool is used to set the fixture to Initial ON or Initial OFF. The Remote Programming Tool, provided as accessory, can also be used to program different parameters. 8 5 2 G – 7 – – – 1 2 B – P 1 – Fixture Type: 852G = Inset Guard Light Technology: 7 = Pro III LED Series Operation Mode: YO = Autonomous, Initial Flash ON YF = Autonomous, Initial Flash OFF Frequency: F1 = 60Hz Power Source F2 = 50Hz Power Source* Fixture Diameter: 12B = 12˝ Optical assembly type L868 size B L-823 Plug Connections: P1 = One Plug Options: 0 = No Options 1 = Arctic Kit * Meets FAA requirement, not ETL certified Outline Drawings 4.745 (120.52) 1.425 (36.19) Ø11.250 (285.75) Dimensions: inches (mm) Instruction Manual: 1065 Shipping Weight: 18 lbs. 8.2 kg Shipping Volume: 0.7 cu. ft. 0.02 m3 1.250 (31.75) 0.75 (19.05) 11.940 (303.28) 9.940 (252.48) 8.417 (213.79) 5.06 (128.52) www.chalp.com Technical Data L852G LED Load and Transformer Requirement Primary Isolation Transformer Option Secondary Isolation Transformer VA (@ 6.6A) Watts (@ 6.6A) Power Factor VA (@ 6.6A) Watts (@ 6.6A) Power Factor Isolation Transformer Type CCR Type 76 86 0.88 70 64 0.91 65W Ferro 112 69 0.62 65 54 0.84 100W Series 125 118 0.95 110 106 0.96 100W Ferro 189 116 0.614 106 99 0.93 200W Series No Options Arctic Kit Accessories Item Description Catalog Number Item Description Catalog Number Base: L-868B, Class I, 24˝ Deep* Connector Kit – L-823, 8 AWG, 0.32˝ to 0.43˝ O.D Heat Shrink Kit – 1 Piece Heat Shrink Kit – Two Pieces Isolation Transformer – 65 W, 6.6/6.6 A AC24242H200303 823KP-D4-D4 10047-2154 10047-1425 33003 Isolation Transformer – 100 W, 6.6/6.6 A Isolation Transformer – 200 W, 6.6/6.6 A Lifting Tool Remote Programming Tool 33004 33006 19999 10047-3066 *Two-piece can may be required depending upon the paving technique. Thin profile bottom cover ensures easy fit in shallow bases. Renewal Parts Description Part Number Description Cover, Bottom Assembly Housing, Optical Assembly L-823 Lead Assembly LED Cartridge, Yellow, 852G 21517 21275-11 21122 21529 Lens Replacement Kit 21480-C O-Ring21385 Power Supply Transformer Internal 50554 Power Supply Circuit Card 21534 Home Office: United States – +1 860-683-4300 International Offices: Canada • China • Dubai • Mexico • Brazil Revised - 6/12 Part Number Visit www.chalp.com for the complete current list of renewal parts and product manuals.