Installation Instructions EcoMeter Operation • ForusewithRR7/9typerelays • DonotrunanyGreengateLowVoltagewiringinthe sameconduitaspowerconductors Load 1 EcoMeter LED OFF ON ON OFF Specifications Technology:PassiveInfrared(PIR) Electrical Ratings: Input: • 24VAC±10%Maximumcurrentneededis25mA persensor. • 1VAmaxforeachsensor • 7VAmaxforeachGERR7/9relay • 8.5VAmaxforeachSierra1070-Brelay Output: • Half-waverectified24VACfor300mspulsefor drivingupto4GERR7/9typerelaysorupto2 Sierra1070-Btyperelays. • IsolatedFormCRelay • IsolatedFormCRelayRatings:1A30VDC/VAC. Time Delays:Self-Adjusting,15seconds/test(10min Auto),Selectable5,15,30minutes Coverage:Majormotion–1000sq.ft. Minormotion–300sq.ft. Light Level Sensing:0to200foot-candles Operating Environment: • Temperature:32°F–104°F(0°C–40°C) • RelativeHumidity:20%to90%Non-condensing Housing:Durable,injectionmoldedhousing. PolycarbonateresincomplieswithUL94VO. Size: • MountingPlate/StrapDimensions: 4.195"Hx1.732"W(106.553mmx44mm) • ProductHousingDimensions:2.618"Hx1.752" Wx1.9"D(66.5mmx44.5mmx48.26mm) LED Indicators:RedLEDindicatesPIRdetection;Green LEDactsasEcoMeterornightlightlocator. Description TheONW-P-1001-RR7OccupancySensingWallSwitchisaPassiveInfrared(PIR)motionsensinglightingcontrol andconventionalWallSwitchall-in-one,usedforenergysavingsandconvenience. Action EcoMeter Apersonentersthespaceand theloadisactivated Benefit OFF Theareaisvacatedandthe lightsturnOFFautomatically ON Increasedawarenessofenergysavings; Actsasanightlightlocator ApersonturnsthelightsOFF manuallyuponexitinganarea ON Increasedawarenessofenergysavingsand remindsindividualstotakecontroloftheir lightingforadditionalsavings;Actsasanight lightlocator Thedaylightfeatureprevents thelightsfromautomatically turningONwhenaperson entersanarea ON Increasedawarenessofenergysavingsand letsindividualknowthatthedaylighting featureisworking ONW-P-1001-RR7-W ONW-P-1001-RR7-V ONW-P-1001-RR7-LA ONW-P-1001-RR7-G ONW-P-1001-RR7-B Installation TheONW-P-1001-RR7canbeinstalledinanystandardsinglegang box.ItmaybeinstalledinthesamemannerasanordinaryWallSwitch. • WiretheONW-P-1001-RR7asdescribedinthewiringsection. • MounttheONW-P-1001-RR7inthejunctionbox. Wiring CAUTION: Before installing or performing any service on a Greengate system, the power MUST be turned OFF at the branch circuit breaker. According to NEC 240-83(d), if the branch circuit breaker is used as the main switch for a fluorescent lighting circuit, the circuit breaker should be marked “SWD.” All installations should be in compliance with the National Electric Code and all state and local codes. NOTE REGARDING COMPACT FLUORESCENT LAMPS: The life of some compact fluorescent lamps (CFLs) is shortened by frequent automatic or manual switching. Check with CFL and ballast manufacturer to determine the effects of cycling. Coverage 1.MakesurepoweristurnedOFFatthebranchcircuitbreaker. 2.Wireunitsasshowninwiringdiagramsperapplicablevoltagerequirements. 3.MountunittoWallBox. 4.TurnpowerbackONatthebranchcircuitbreakerandwait2minutesfortheunittostabilize. 5.Makenecessaryadjustments.(SeeCheckoutandAdjustmentssection) 6.InstallWallSwitchplate. TheONW-P-1001-RR7isdesignedforofficesupto300squarefeet. 36 , , 20 Minor Motion, IR PIR Technology Major Motion, IR Thesensor’ssegmentedlensdividesthefieldofviewintosensorzones,anddetectsthechangesintemperature thatarecreatedwhenaperson,orpartofapersonassmallasahand,passesintooroutofasensorzone. , TheONW-P-1001-RR7allowsthecontroloffourGERR7/9relaysortwoSierra1070-Brelays. 8 Thesensormaybeinterfacedtoanenergymanagementsystemthatacceptseitheranormallyopenornormally closeddrycontactviathesensor’sFormCrelay. ThesensorcanbeconfiguredtoenhanceenergysavingsbysettingtheunitformanualONoperation. InAutomaticONMode,thelightsturnONautomaticallywhenapersonenterstheroom.InManualONMode,the lightsareturnedONbypressingtheuniversallyrecognizedlighticonPushbutton.Ineithermode,thelightsstayON aslongasthesensordetectsmotionintheroom.Whentheroomisvacated,thelightsturnOFFautomaticallyafter apresetTimeDelayinterval. Thesensorincludesself-adaptivetechnologythatcontinuallyadjuststoconditionsbyadjustingsensitivityand Maximum coverage area may TimeDelayinReal-time.ByadjustingsensitivityandTimeDelayautomatically,thesensorismaximizingthepotential vary somewhat according to room energysavingsthatareavailableintheparticularapplication. shape and the presence of obstacles. TheEcoMeterprovidesavisualindicatorofenergyusage,increasingenduserawarenessandreminding individualstotakecontroloftheirlightingtomaximizeenergysavings. TheDaylightingfeaturepreventslightsfromturningON,whentheroomisadequatelyilluminatedbynaturallight. Walk-ThroughfeaturemaximizesenergysavingsbynotleavingthelightsONafteramomentaryoccupancy.The sensorwillswitchthelightsONwhenitdetectsapersonenteringthearea.Ifthesensordoesnotcontinuetodetect Location motion20secondsfollowingtheinitialactivation,itwillautomaticallygotoashorter2minuteTimeDelay. WheninstallingtheONW-P-1001-RR7inanewjunctionbox,choosetheswitchlocationcarefullytoprovideoptimum TrackingModeallowstheloadconnectedtotheFormCrelaytofollowthestateofthesensor’sbluelead. coverageoftheoccupiedarea.WhenreplacinganexistingWallSwitch,bearinmindthattheremustbeaclearLineHVACModeallowstheloadconnectedtotheFormCrelaytoremainONwhenthelightsareturnedOFFmanually. of-sightbetweenthesensorandtheareatobecovered.AvoidpointingtheONW-P-1001-RR7directlyintothehallway ApplicationsmayincludekeepingtheroomatadesiredtemperaturewhilegivingapresentationandthelightsareOFF. whereitmaydetectpassers-by. Wiring Diagram 1 NEUTRAL LOAD HOT RELAY 24 VAC BLACK • Readallinstructionsonbothsidesofthissheetfirst • InstallinaccordancewithALLlocalcodes • Forindooruseonly # # # # # RED General Information Model Model Model Model Model BLUE P/N 9850-000347-01 NeoSwitch Passive Infrared (PIR) Technology RR7 Compatible Occupancy Sensing Wall Switch TO ADDITIONAL RELAYS NOTE- USE ONLY APPROVED RELAYS: GE RR7 TYPE MAXIMUM OF FOUR OR SIERRA 1070-B TYPE MAXIMUM OF TWO. ORANGE (N.O.) WHITE GRAY (COMMON) RED PURPLE (N.C.) BLACK CAUTION: If a room is wired for two circuits using two separate hot leads, it is very important to connect only one circuit per relay. Both circuits must be fed from the same phase. Eaton’s Cooper Controls Business 203 Cooper Circle Peachtree City, Georgia 30269 www.coopercontrol.com DIP Switch Settings DIP Switch Legend Time Delay DIP Switch Activation Isolated Relay PIR Sensitivity Walk-Through Mode Override EcoMeter Relay 1 1 2 Auto* 5 Minutes Auto Tracking Full Disable Enable Disable Manual HVAC 50% Enable Disable Enable 15 Minutes 30 Minutes *Self-Adjusts to 10 min. user mode 3 4 6 5 7 8 Default = 1 2 3 4 5 6 7 8 Checkout and Adjustment AdjustmentsshouldbemadewiththeHVACsystemonsothattheinstallerwillbeabletodetecttheeffectof airflowontheoperationoftheONW-P-1001-RR7.Useonlyinsulatedtoolstomakeadjustments. Immediatelyafterapplyingpowertothelightingcircuit,waitapproximatelytwominutesfortheswitchtopowerup andstabilize. Self-Adjust Sensorisshippedinself-adjustmode.This appliestoTimeDelayandPIRsensitivity.In Red (PIR) preparationfortheInstallerTest,theTime Detection LEDs PIR Lens Delayissetto15seconds,afterthesensoris installed,poweredONandhasstabilized,the Daylight unitwillTime-out15secondsafterthelast Sensor Level motiondetected.Coverageandsensitivity Adjustment canbeconfirmedbywatchingtheRed(PIR) indicatorLEDonthefrontofthesensor,while DIP Switches movingaroundtheroom. 1.WalkaroundtheroomandmonitorLEDs. 2.Standindifferentpartsoftheroomand waveyourhands.LEDshouldonlyturn ONforonesecondwitheachmotion. ON/OFF Button (IfLEDdoesnotturnON,gotoInstaller Adjustments–SensitivityAdjustment Section) 3.Standstillthreetofourfeetawayfromsensorforfiveseconds.LEDshouldnotturnON.(IfLEDturnsON,goto InstallerAdjustments–SensitivityAdjustmentssection) 4.Walkoutsidetheroomandwait15secondsforthelightstoturnOFF.(IflightsdonotturnOFFgotoInstaller AdjustmentsSection) 5.Re-entertheroomtoactivatesensor.(IflightsdonotturnONgotoTroubleshootingSection) 6.AtthispointyoucanexittheroomandletthesensorTime-out.Whenthesensortimes-outandisOFFforfive minutes,theunitwillgotoa10minuteTimeDelayusermodesetting. Note:ToplaceintoTestMode,toggleDIPSwitch8outofitscurrentposition,wait3seconds,andthenbackintoitsoriginalposition. Daylight Adjustments ThedaylightingfeaturepreventsthelightsfromturningONwhenthe roomisadequatelyilluminatedbynaturallight.Ifthereisenoughlightinthe roomregardlessofoccupancy,thesensorwillholdthelightsOFF.Ifthere isnotenoughlightintheroom,thesensorwillallowthelightstoturnON whenoccupied.Thesensorwillnotallowthedaylightingfeaturetoturnthe loadOFFuntilthespaceisvacantorthelightlevelrisesabovethesetpoint andtheTimeDelayexpires.WhileinManualActivationMode,ifsomeone attemptstoturntheloadONandthereissufficientdaylightavailablethe DaylightingfeaturewillholdthelightsOFF. 1.Setthelightlevelwhentheambientlightisatthelevelwhereno artificiallightisneeded.Ifthisfeatureisnotneeded,leavethelight levelatmaximum(fullyCW). 2.Withtheload(s)ON,putthesensorintoTestMode.Toplaceintotest mode,toggleDIPSwitch8outofitscurrentposition,wait3seconds andthenbackintoitsoriginalposition. 3.SettheLightleveltominimum(fullyCCW). 4.LetthesensorTime-outsolightsareOFF.EnterthespaceandlightsshouldremainOFF. 5.MakesurenottoblockthesensorfromthedaylightsourceandadjustthelightlevelpotentiometerCWinsmall increments.(Pause5secondsbetweeneachadjustment) 6. LightswillnotturnONuponoccupancyactivation,whentheambientlightlevelexceedsthedaylightthresholdsetting. Time Delay Adjustments Peoplewhoremainverystillforlongperiodsoftimemay needalongerTimeDelaythanthedefaultsettingof10minutes. Aslongastheself-adjustingfeatureisenabled,theswitch willrespondtoeachpairofFalse-offswithnonormalOFFin between,byalternatelymakingslightadjustmentstoeitherTime Delay(by2minuteincrements)orsensitivity,sothereshouldbe noneedformanualadjustment.Ifmanualadjustmentisdesired, refertoTimeDelaysettingsinDIPSwitchlegend. ResetsensorTimeDelaytofactorysettingsbymovingDIP Switches1and2down.(IfDIPSwitches1and2arealready down,toggleDIPSwitch1outofitscurrentposition,wait3 seconds,andthenbacktoitsoriginalposition). Troubleshooting Issue Possible Causes Suggestions SensorisinManualONmode PressPushbutton.IfAutoMode isdesiredchangeActivationModetoAuto. SensorwasturnedOFFmanually.IftheSensor Lights wasturnedOFFmanuallybeforetheTimeDelay Will Not expired,lightswillremainOFFfortheremainder Turn ON oftheTimeDelay. automatically Lights Will Not Turn ON manually CheckEcoMeterLED.IfLEDisONthisis anindicationthatthelightswereturnedOFFmanually. PressthePushbuttontoturnthelightsbackON. DaylightFeatureEnabled IfalllightsarerequiredtoturnON adjustdaylightpotentiometer. Powerinterruption Checkincomingvoltageand/orwiring. DaylightFeatureEnabled IfalllightsarerequiredtoturnON adjustdaylightpotentiometer. Powerinterruption Checkincomingvoltageand/orwiring. If lights will still not turn ON, set sensor to override mode and call Technical Services at 1-800-553-3879 DIP Switches 1&2 1 2 3 4 5 6 7 8 Tracking/HVAC WhentheoccupancysensorturnsthelightsONorOFFeitherbydetectionoramanualpress,thelightscanbeturned OFFmanuallybypressingthePushbutton.ThelightswillremainOFFaslongasthereismotionintheroom,oncethe occupancysensornolongerdetectsmotionandtheTimeDelayexpires,thesensorwillrevertbacktoits normaloperation. TrackingMode–Isolatedrelaywillfollowoperationofsensorinallmodes.Relaystatewillchangewhenoccupancy sensorisactivatedand/orturnedONorOFFmanually. HVACMode–IsolatedrelaywillonlychangestateinAuto/ManualONandAutoOFFmodes.Thestatewillnot change,iftheoccupancysensoristurnedOFFmanually.TherelaywillchangestateoncetheTimeDelayexpires. Override Theoverridesettingallowsthesensortooperateasaserviceswitchintheunlikelyeventoffailure. 1.MoveDIPSwitch8up. 2.ThePushbuttoncanbeusedtomanuallyturnlightsONorOFF. Override MakesuresensorisnotinOverrideMode(DIPSwitch8up). Self-Adjust IfsensorisinSelf-AdjustMode,itmaybepossibleforthe unittohaveincreasedtheTimeDelaytoa30minutedelay. IfthelightsdonotturnOFFafter30minutesfollownextstep. 30MinuteDelay MaximumTimeDelayis30Minutes.CheckDIPSwitches toverifyDIPSwitchsettings.IflightsdonotturnOFFatthe setTimeDelay,checknextstep. PIRactivatedbyheatsourceotherthanoccupant MoveDIPSwitch5up. Lights Will Not Turn OFF automatically Lights Will Not Turn OFF manually CallTechnicalServices If lights will still not turn OFF, call Technical Services at 1-800-553-3879 Warranties and Limitation of Liability Pleaserefertowww.coopercontrol.comundertheLegalsectionforourtermsandconditions. Installer Adjustments PIR Sensitivity 1.Standindifferentareasoftheroomandwaveyourhands. 2.IftheRedLEDdoesnotturnON,checkforanyobstructions. 3.Standstillthreetofourfeetawayfromsensorforfiveseconds.LEDshouldnotturnON. 4.IfRedLEDturnsONwithoutmotionorisconstantlyONadjustPIRsensitivityto50%bymovingDIPSwitch5up. Field-of-view outside the space 1.AdjustPIRsensitivityto50%bymovingDIPSwitch5up. 2.Usenon-reflectivetapestripstocovertheportionsofthesensorlensthatviewoutsidethespace. Printed in Malaysia Eaton’s Cooper Controls Business 203 Cooper Circle Peachtree City, Georgia 30269 www.coopercontrol.com