An adjustable Multi-lamp Recessed fixture for trimless installation suitable
for downlighting and accent applications. Utilizes 12V MR16 lamps.
Catalog #
For new construction applications. Insulation must be kept 3” from all
sides and at least 1” above the housing.
Comments
Type
Project
Date
Prepared by
SPECIFICATION FEATURES
Housing
All steel construction. Housing includes
perforated mesh bottom surface for trimless
installation in drywall/plaster ceilings by
allowing the ceiling’s mudding compound
to be applied right up to the edge of the
fixture opening. Includes beveled “knifeedge” lip to ensure a clean edge. Housings
can accommodate 0.50” or 0.625” ceiling
thickness.
Electrical
Integral electronic or magnetic low
voltage transformers. 11.5V. Dimmable*.
Transformers and electrical are accessible
through removable doors on the housing
sidewall.
Labels
cULus listed for non-type IC
applications, suitable for use in damp
locations.
COMBOLIGHT®
LV SERIES
Recessed Multi-Lamp
Fixture
Ceiling Cut-Outs
CV1 = 7.00” x 7.00”
Lamps
CV2 = 7.00” x 11.00”
One, two, three, four, five, or six 12V MR16
CV3 = 7.00” x 15.00”
lamps mounted in adjustable bezels.
Each lamp can accept up to two optical
CV4 = 7.00” x 19.00”
accessories. Special LV style lampholder
CV5 = 7.00” x 23.00”
with 380º x 45º locking lamp adjustment.
Locking horizontal positional adjustment can CV6 = 7.00” x 27.00”
be achieved for added versatility and aiming. CVX = 11.00” x 11.00”
Bi-pin sockets pre-wired in housing. Snoots
and spill shields included.
System Protection:
Thermal protection provided to guard
against overheating and misuse of
insulation over and around fixture. Vent
holes in housing provide cooler operation.
Junction Box
Junction box is UL listed for through branch
wiring, (access above ceiling not required)
for 8 #12, 90°C supply conductors. J-Box
integrated with housing and is accessible
through the ceiling opening.
1, 2, 3, 4, 5, or 6 Light
12V MR16
New Construction
Trimless Housing
* Use only dimmers specifically designed for use with
magnetic or electronic transformers. Low voltage
Mounting
Butterfly Brackets accept 1/2” EMT, C
fixtures using magnetic transformers may produce
Channel, Tbar fasteners, and bar hangers. audible sound when used with dimmers, which may
Four tabs on housing for securing to
be objectionable in acoustically critical areas.
structure.
E
A
7.18”
182mm
Dimensions in inches / mm
Config.
A
B
C
D
F
E
CV1
13.00” 10.00” 4.00” 4.00” 11.75” 10.00”
330
254
102
102
298
254
CV2
17.00” 14.00” 8.00” 4.00” 11.75” 10.00”
432
355
204
102
298
254
CV3
21.00” 18.00” 12.00” 4.00” 11.75” 10.00”
533
457
305
102
298
254
CV4
25.00” 22.00” 16.00” 4.00” 11.75” 10.00”
635
559
406
102
298
254
CV5
29.00” 26.00” 20.00” 4.00” 11.75” 10.00”
737
660
508
102
298
254
CV6
33.00” 30.00” 24.00” 4.00” 11.75” 10.00”
838
762
610
102
298
254
CVX
17.00” 14.00” 8.00” 8.00” 17.28” 14.00”
432
355
204
204
438
355
F
B
C
4.00”
102mm
Trimless Installation
D
380º x 45º Adjust +
Horizontal Travel
Thermal
Protector
Integral Low Voltage Transformers
ORDERING INFORMATION
N
Configuration
CV1 = One (1) Light
CV2 = Two (2) Light
CV3 = Three (3) Light
CV4 = Four (4) Light
CV5 = Five (5) Light
CV6 = Six (6) Light
CVX = Four (4) Light Sq.
www.cooperlighting.com
Housing
N = New Construction
Lamp Type / Wattage Label
037M16 = 37 Watt max. MR16 12V
042M16 = 42 Watt max. MR16 12V
050M16 = 50 Watt max. MR16 12V
071M16 = 71 Watt max. MR16 12V
Power Supply
E = Electronic Low Voltage
Transformer
M = Magnetic Low Voltage
Transformer (50w max.)
Power Supply Voltage
1 = 120V
2 = 277V
4 = 240V
Housing Interior Finish
W = White
B = Black
S = Industrial Silver
Specifications and Dimensions subject to change without notice.
RSA Lighting • 7945 Orion Ave. • Van Nuys, CA 91406 • 818-742-3838 • FAX 818-742-3801