PORTFOLIO TM D ES C R IPTION Low brightness 7-3/8-inch aperture reflector for use with a 42W Triple Twin Tube 4-pin lamp. The precisely formed non-imaging reflector ensures 45° cutoff to lamp and lamp image and the one piece design eliminates light leaks at the ceiling. Standard features include low iridescent finish on all reflector colors to eliminate "rainbowing" and one electronic ballast. Venting ensures maximum lamp life and lumen output. Optics offer unparalleled performance in glare free lighting with a smooth beam devoid of hot spots. Medium beam, wide beam, lensed reflectors and open wall wash trims are interchangeable within the same housing. Type Catalog # Project Date Comments Prepared by SPE C IFIC A TION FEA T U R E S Re f l e c t o r U ni v e rs a l Moun ting B racket Electron ic B allast .050" thick aluminum, in a one piece spun macrofocal parabolic contour. Available in a variety of Alzak® finishes. Positive reflector mounting pulls trim tight to ceiling. Accepts 1/2" EMT, C Channel, T bar fasteners, and bar hangers. Adjusts 5" vertically from above or below ceiling. Electronic ballast provides full light output and rated lamp life. Provides flicker free and noise free operation and starting. End of lamp life protection is standard. Condui t F i tti ngs Trim Ring Options Die cast screw tight connectors. Self flanged or molded white trim ring. Rimless or metal trim ring accessories available. J unc ti on Box So c k e t C a p One piece vented and finned die cast aluminum cap for maximum thermal performance. Labels cULus listed, standard damp label. Listed for eight #12AWG (four in, four out) 90°C conductors feed through branch wiring. 1/2" and two 3/4" pry outs. Positioned to allow straight conduit runs. Access to junction box by removing reflector. Op tion s & Accessories TRM=Metal Trim Rings to replace molded trim ring. TRR=Rimless Trim Rings for minimal flange appearance in plaster ceilings. H ou s i n g M o u n t i n g F ra me One piece precision die cast aluminum 1-1/2" deep collar accommodates varying dimensions of ceiling materials. C7042 C7401/7400 Soc ke t 42W TTT or PLT 4-pin GX24q4 base with fatigue free stainless steel lamp spring ensures positive lamp retention. Compact Fluorescent STEPREPEAT> 7-Inch Medium Beam Open Downlight Top View ENERGY DATA 42W TTT 4-pin Ballast: Electronic 13-5/16" [338mm] 11-5/8" CP 12-1/8" 120V Input Watts: 48 Line Amps: 0.32 277V Input Watts: 48 Line Amps: 0.18 Power Factor: >0.99 THD: <10% Min. Starting Temperature: -10°F (0°C) Sound Rating: Class A Standards NOTES: Accessories should be ordered separately. For additional options, please consult your Cooper Lighting Representative. Alzak is a registered trademark of Aluminum Company of America. 13-3/4" [349mm] 12-7/8" [327mm] 16-1/8" [409mm] (w i t h I E M O p t i on) 7-3/8" [187mm] 8-1/8" [206mm] 8-3/4" [222mm] Specifications and dimensions subject to change without notice. Consult your representative for additional options and finishes. ADP040653 2013-09-26 16:12:33 C7042 C7401/7400 OR D ER ING INFOR M A TION EXAMPLE: C7042E 7401WMH Housing Wa tt a g e Ballast E=120/277V 50/60 Hz Electronic 3E=347V 50/60 Hz Electronic D5LT42=42W 120-277V Fifth Light (DALI Dimming) 3D5LT42=42W 347V Fifth Light (DALI Dimming) D42=42W 120-277V Lutron Ecosystem Dimming C70=7" CF Vertical 42=(1) 42W TTT or PLT Lamp Tri m s Options CP=Chicago Plenum EM=Emergency Module with RemoteTest Switch IEM=Emergency Module with integral test switch 7401=Self Flanged 7400=Molded Trim Ring, White 7401E=Self Flanged, use with IEM 7400E=Molded Trim Ring, White, use with IEM Finish Options LI=Low Iridescent Clear H=Haze WMH= Warm Haze G=Gold WH=Wheat W=Gloss White GP=Graphite GPH=Graphite Haze WF=White Painted Flanged (Self Flanged only) A c c e s s o ri e s HB26=C Channel Bar Hangers, 26" Long, Pair HB50=C Channel Bar Hangers, 50" Long, Pair TRM7=Metal Trim Ring, Specify Finish1 TRR7= Rimless Trim Ring, White1 FK5=5 Amp Field Installable Fuse Kit 300V Max DT7=Deco Trims1 RMB-22=Wood Joist Bar Hanger, 22" Long, Pair HSA7=Slope Adapter for 7" Aperture Housings, Specify Slope Notes: 1 Order trim with polymer trim ring (Consult specification sheet for ordering information and options). PHOTOM ETR IC S C7042 7401/7400 Test No. H23274 C7042 7000LI Medium Beam Reflector Lamp=42W TTT Lumens=3200 Spacing Criterion=0.8 Efficiency=48.9% 310 620 930 1240 Average Luminance Candlepower Candlepower Distribution 1550 Deg. 0 5 15 25 35 45 55 65 CD 1876 1902 1418 975 630 130 7 0 75 85 90 0 0 0 Deg. 45 55 65 75 85 Cone of Light CD/SQ M 6668 443 86 0 0 Distance to Illuminated Plane Initial Nadir Footcandles 5'6" 6'6" 8'0" 10'0" 12'0" 14'0" Beam Diameter 4'0" 5'0" 6'0" 7'6" 9'0" 10'6" 62 44 29 19 13 10 Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot. Footcandle values are initial, apply appropriate light loss factors where necessary. EM Multiplier (in emergency mode) 1860 EM=.24 Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 90-180 0-180 Lumens 1023 1421 1562 1565 0 1565 %Lamp 32.0 44.4 48.8 48.9 0.0 48.9 C o e f fi c i e n t o f U t i l i z a t i o n %Luminaire 65.4 90.8 99.8 100.0 0.0 100.0 rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 80% 70 50 30 10 50 70% 30 50% 10 50 58 58 58 58 57 57 57 54 56 55 54 53 54 53 52 52 54 51 50 48 51 49 48 49 51 49 46 45 48 46 44 47 49 46 44 42 45 43 42 44 47 43 41 39 43 41 39 42 45 41 38 37 41 38 37 40 43 39 36 34 38 36 34 38 41 36 34 32 36 34 32 36 39 34 32 30 34 32 30 34 37 32 30 28 32 30 28 32 rc=Ceiling reflectance, rw=Wall reflectance, RCR=Room cavity ratio CU Data Based on 20% Effective Floor Cavity Reflectance. 10 50 30% 10 50 10 0% 0 54 50 47 44 41 38 36 34 32 30 28 52 50 48 46 43 41 39 37 35 33 31 52 49 46 43 41 38 36 34 32 30 28 50 48 46 44 43 41 39 37 35 33 31 50 47 45 42 40 38 36 34 32 29 28 49 46 44 42 39 37 35 33 31 29 27 Specifications and dimensions subject to change without notice. Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 468.4801 10% ADP040653 2013-09-26 16:12:33 C7042 C7401/7400 C7042 7401/7400 Test No. H23275 C7042 7000LI Medium Beam Reflector Lamp=42W PLT Lumens=3200 Spacing Criterion=1.0 Efficiency=41.8% 240 480 720 960 Average Luminance Candlepower Candlepower Distribution 1200 Deg. 0 5 15 25 35 45 55 CD 1296 1443 1283 917 574 40 6 65 75 85 90 1 0 0 0 Deg. 45 55 65 75 85 Cone of Light CD/SQ M 2052 379 89 0 0 Distance to Illuminated Plane Initial Nadir Footcandles 5'6" 6'6" 8'0" 10'0" 12'0" 14'0" Beam Diameter 5'6" 6'6" 8'0" 9'6" 11'6" 13'6" 43 31 20 13 9 7 Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot. Footcandle values are initial, apply appropriate light loss factors where necessary. EM Multiplier (in emergency mode) 1440 EM=.24 Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 90-180 0-180 Lumens 920 1270 1336 1339 0 1339 %Lamp 28.7 39.7 41.7 41.8 0.0 41.8 C o e f fi c i e n t o f U t i l i z a t i o n %Luminaire 68.7 94.8 99.7 100.0 0.0 100.0 rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 70 50 80% 30 10 50 70% 30 10 50 50% 10 50 10 50 10 0% 0 50 50 50 50 49 49 49 46 46 45 45 43 43 42 43 40 38 36 33 32 30 28 26 25 43 41 39 38 36 34 32 31 29 28 42 39 37 35 33 31 30 28 26 25 41 40 38 37 35 34 32 30 29 27 41 39 37 35 33 31 29 28 26 25 40 38 36 34 32 31 29 27 26 24 48 47 46 45 46 45 44 44 46 44 43 42 44 42 41 42 44 42 40 39 41 40 38 40 42 40 38 36 39 37 36 38 40 37 35 34 37 35 34 36 39 36 34 32 35 33 32 35 37 34 31 30 33 31 30 33 35 32 30 28 32 30 28 31 34 30 28 26 30 28 26 29 32 28 26 25 28 26 25 28 rc=Ceiling reflectance, rw=Wall reflectance, RCR=Room cavity ratio CU Data Based on 20% Effective Floor Cavity Reflectance. 30% Specifications and dimensions subject to change without notice. Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 468.4801 10% ADP040653 2013-09-26 16:12:33