PORTFOLIO TM D ES C R IPTION Recessed lens downlight with 6 inch aperture for horizontal ED17 medium base metal halide lamp. Universal input electronic ballast features end of life shutdown. Fixture is suitable for commercial construction and shallow plenum. Insulation must be kept 3” from top and sides of housing. Two stage reflector system produces wide beam distribution with excellent light control and low aperture brightness. Type Catalog # Project Date Comments Prepared by SPE C IFIC A TION FEA T U R E S H ou s i n g L owe r Shi e l di n g R eflecto r In su latio n Detecto r Steel housing encloses optical system protecting reflectors from damage. Access door allows splice inspection and ballast service through aperture. Spun 0.050” thick aluminum parabolic contour provides 65° lens and lens image cutoff. Self flanged standard with optional white painted flange. Also available with polymer trim ring. Trim ring may be interchanged with metal trim ring available in various finishes or removed for rimless installation, see accessories. Available in all Portfolio Alzak® finishes. Self resetting detector opens circuit if insulation is improperly installed. Pla s t e r F r a m e / Col l a r Die cast aluminum collar accommodates ceiling materials up to 1-1/2” thick. U n i v e r s a l M o u n t ing Bra c ke t Accepts ½” EMT, C channel and bar hangers and adjusts 5” vertically from above the ceiling. Shi e l di ng Ju n c t i o n B o x Tri m Re te nti on (6) ½” and (2) ¾” trade size pry outs positioned to allow straight conduit runs. Listed for (8) #12 AWG (four in, four out) 90°C conductors and feed thru branch wiring. Lower reflector is retained with two torsion springs holding the flange tightly to the finished ceiling surface. 0.125” thick diffuse glass lens is captive during lamp replacement. B allast Universal input 120/277V electronic ballast provides noise free operation, improved efficiency and increased lamp life as compared with magnetic ballast. Regulated output power over a wide range of ANSI lamp voltages results in excellent color stability over time. End of lamp life shutdown – reset power to restore output. MD6S50 MD6S70 Co d e Co mplian ce Upper Reflector Soc ke t Thermally protected and cULus listed for protected wet locations. Optional City of Chicago environmental air (CCEA) marking for plenum applications. EMI/RFI emissions per FCC 47CFR Part 18 non consumer limits. 6140/6141 Metal Halide ED17 STEPREPEAT> Pulse rated E26 medium base socket accepts unprotected lamps. Clear anodized spun 0.050” thick aluminum produces wide distribution. 6-Inch Shallow Wide Beam Lens Downlight 9 7/8" [239 mm] ENERGY DATA 50W 5 5/8" [143 mm] 6 3/8" [162 mm] 7 1/4" [184 mm] 120V Input Power: 60W 277V Input Power: 60W 120V Input Current: 0.51A 277V Input Current: 0.22A Minimum Starting Temp: -15°C, +5°F THD: <20% T OP V IE W Power Factor: >0.90 Sound Rating: A 70W 18" [459mm] 120V Input Power: 86W 277V Input Power: 84W 120V Input Current: 0.72A 277V Input Current: 0.81A Minimum Starting Temp: -20°C, -5°F THD: <20% Power Factor: >0.90 Sound Rating: A 18 5/8" [472 mm] Specifications and dimensions subject to change without notice. Consult your representative for additional options and finishes. ADP090825 2013-09-27 08:02:18 MD6S50 MD6S70 6140/6141 ORDER IN G INFOR M A TION S A M P L E N U M B E R : M D 6 S 7 0 = 6” shallow housing with UNV 120/277V electronic ballast for a 70W ED17 MH lamp 6 1 4 1 L I = 6” wide beam reflector, self flanged, specular clear, low iridescent (Order universal housing and trim separately) Housing Wattage MD6S=6” shallow MH housing MD6SCP=6” shallow MH housing, CCEA listed for City of Chicago requirements Ballast E=Electronic, UNV 120/277V 50/60Hz Trim Finish 6140=6” wide beam reflector, white polymer trim ring 6141=6” wide beam reflector, self-flanged 50=50W MH lamp 70=70W MH lamp Alzak ® Finishes LI=Specular clear, low iridescent H=Semi specular clear WMH=Warm haze G=Gold WH=Wheat GP=Graphite GPH=Graphite haze B=Black Options Accessories WF=White painted flange (self flanged only) HB26=Bar hanger, 26” long, pair HB50=Bar hanger, 50” long, pair RMB22=Bar hanger for wooden joists, 22” long, pair HSA6*=Slope adapter for 6” aperture, specify slope TRM6*=Metal trim ring, specify finish TRR6=Rimless trim ring H347=347V stepdown transformer, 75VA H347200=347V stepdown transformer, 200VA PH OTOM ETR IC S Candlepower Distribution Curve Cone of Light Spacing Criteria = 0.7 Efficiency = 53.0% Downlight 80° 300 70° 60° 600 50° Test No. H28068 MD6S 6141LI Lamp = MP50/CU/U/MED 900 Distance Fixture to Lighted Plane 4'0" 6'0" 8'0" 10'0" 12'0" 14'0" Initial Footcandles at Nadir Beam Diameter 93 41 23 15 10 8 2'6" 4'0" 5'0" 6'6" 8'0" 9'0" 50W ED17 40° 1200 1500 10° 20° 30° Coefficients of Utilization Ceiling 80% 70% 50% 50 30 10 50 10 Wall % 70 50 30 10 RCR Zonal cavity method -- floor reflectance = 20% 0 63 63 63 63 62 62 62 59 59 1 60 58 56 55 57 55 54 55 52 2 56 53 50 48 52 49 47 50 46 3 52 48 45 42 47 44 42 46 41 4 49 44 40 38 43 40 37 42 37 5 46 40 37 34 40 36 34 39 33 6 43 37 33 30 37 33 30 36 30 7 40 34 30 28 34 30 28 33 27 8 38 32 28 25 31 28 25 31 25 9 35 29 26 23 29 26 23 29 23 10 34 27 24 21 27 24 21 27 21 PH OTOM ETR IC S Candlepower Distribution Curve Spacing Criteria = 0.6 Efficiency = 48.8% Downlight 80° 500 70° 60° 1000 50° 1500 40° 2000 2500 Cone of Light 10° 20° 30° Distance Fixture to Lighted Plane 4'0" 6'0" 8'0" 10'0" 12'0" 14'0" Test No. H28075 MD6S 6141LI Lamp = M70/C/U 70W ED17 Initial Footcandles at Nadir 139 62 35 22 15 11 Beam Diameter 3'6" 5'0" 6'6" 8'6" 10'0" 11'6" Coefficients of Utilization Ceiling 80% 70% 50% 50 30 10 50 10 Wall % 70 50 30 10 RCR Zonal cavity method -- floor reflectance = 20% 0 58 58 58 58 57 57 57 54 54 1 55 53 52 50 52 51 49 50 48 2 51 48 46 44 47 45 43 46 42 3 48 44 41 39 43 40 38 42 38 4 45 40 37 34 40 36 34 38 34 5 42 37 33 31 36 33 31 35 30 6 39 34 30 28 33 30 28 33 27 7 37 31 28 25 31 28 25 30 25 8 34 29 25 23 29 25 23 28 23 9 32 27 24 21 27 23 21 26 21 10 31 25 22 20 25 22 20 24 20 Specifications and dimensions subject to change without notice. Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 468.4801 ADP090825 2013-09-27 08:02:18