Catalog # Type

advertisement
PORTFOLIO
DESCRIPTION
A low brightness non-ferrous 6" diameter downlight for use with A21 lamps
(200W max, frosted lamps recommended). The precisely formed
non-imaging reflector ensures 55° cutoff to lamp and lamp image. The
modular housing system supports various downlight and wallwash
reflectors.
Type
Catalog #
Project
Date
Comments
Prepared by
SPECIFICATION FEATURES
A ... Reflector
Positive reflector mounting pulls
trim tight to ceiling. 0.050" spun
aluminum reflector. Available in a
variety of Alzak® finishes.
B ... Trim Ring
Self flanged or molded white trim
ring. Rimless trim ring accessory
available (see Accessories).
C ... Socket Cap
One piece heat dissipating die-cast
aluminum with non-ferrous
reflector attachment.
D ... Housing
Precision die-cast aluminum
1-1/2" (38mm) deep collar.
Optical assembly adjusts within
the housing to accommodate
ceilings up to 4 1/4" (108mm) thick.
Knockouts for three 1/2" and two
3/4" conduits. Access to junction
box by removing reflector.
E ... Universal Mounting
Bracket
Accepts various Non-Ferrous
hanger bars by others. Provides 5"
total adjustment.
H ... Socket
Medium base porcelain socket with
nickel plated screw shell and non
ferrous fasteners.
F ... Conduit Fittings
Die-cast screw tight connectors
with aluminum lock nut and
stainless steel screw.
G ... Junction Box
Made entirely of non-ferrous
material. U.L. listed for four in,
four out #12 at 90°C pull through
branch wiring.
I ... Socket Cap Support
Non-ferrous brackets with stainless
steel hardware to allow socket cap
adjustment.
Insulation Detector
Self-resetting insulation detector
opens circuit if insulation is
improperly installed.
Labels
cULus Listed, damp location.
Options & Accessories
TRR=Rimless Trim Rings for
minimal flange appearance in
plaster ceilings.
HD6MRI
6751/6750
200W MAX
A21
6" WIDE BEAM
DOWNLIGHT
T o p V i ew
9 9/16”
[243mm]
12 15/16”
[328.80mm]
5 11/16”
[144.47mm]
6 3/8”
[161.48mm]
7 1/4”
[184.15mm]
11 1/4”
[286.26mm]
ORDERING INFORMATION
Sample Number: Complete unit consists of housing, ballast and trim.
Housing
HD6MRI=6"
Non-Ferrous
Incandescent
Options
CP=Chicago
Plenum
Trims
6751=Self Flanged
Finish
B=Specular Black
6750=Molded Trim Ring
G=Specular Gold
GP=Graphite
Option
WF=White Painted
Flanged (Self
Flanged only)
Derated Wattage
Label
DR*=DeRated, Specify
Wattage
Accessories
TRR6=Rimless Trim Ring, White
GPH=Graphite Haze
H=Semi-Specular Clear
LI=Specular Clear
W=Gloss White
WH=Wheat
WHH=Wheat Haze
WMH=Warm Haze
Specifications and Dimensions subject to change without notice.
Consult your representative for additional options and finishes.
ADP050103
09/27/2013 5:20:53 PM
HD6MRI 6751/6750
PHOTOMETRICS
Test No. H22240
HD6-6750C
Lamp=150W A21
Inside
Frosted
Lumens=2850
Spacing Criteria=1.4
Efficiency=71.0%
220
440
660
Average
Luminance
Candlepower
Candlepower Distribution
880
Cone of Light
Deg.
CD
Deg.
CD/SQ M
0
5
15
25
841
847
957
1089
45
55
65
75
48015
7490
0
0
35
1038
85
0
45
55
569
72
65
0
75
85
90
0
0
0
Distance to
Illuminated Plane
Initial Nadir
Footcandles
5'6"
6'6"
Beam
Diameter
9'0"
10'6"
28
20
13
8'0"
10'0"
12'0"
14'0"
13'0"
16'0"
19'0"
22'6"
8
6
4
Beam diameter is to 50% of maximum footcandles, rounded
to the nearest half-foot.
Footcandle values are initial, apply appropriate light loss
factors where necessary.
1100
Reflector Multiplier
Low Iridescent = 0.95
Haze = 0.90
Zonal Lumen Summary
Zone
0-30
Lumens
858
0-40
0-60
0-90
90-180
0-180
1495
2024
2024
0
2024
%Lamp
30.1
52.5
71.0
71.0
0.0
71.0
Straw = 0.85
Wheat = 0.85
Coefficient of Utilization
%Luminaire
42.4
73.9
100.0
100.0
0.0
100.0
rc
rw
RCR
80%
70%
50%
30%
10%
0%
70
50
30
10
50
30
10
50
10
50
10
50
10
0
0
1
2
3
4
85
80
85
78
85
76
85
75
83
77
83
75
83
73
79
74
79
71
76
71
76
69
72
69
72
67
71
66
76
72
68
72
67
62
69
63
58
67
60
54
71
66
61
68
62
57
66
60
54
69
64
59
65
59
53
67
62
58
63
58
53
65
61
57
62
57
52
61
56
51
5
6
63
59
55
51
57
52
48
44
52
48
43
39
49
44
39
35
56
52
47
43
52
47
43
38
49
44
39
35
55
51
46
42
48
44
39
35
54
50
45
41
48
43
39
35
52
49
44
41
47
43
39
35
46
42
38
34
48
40
35
31
39
34
31
38
31
44
36
31
28
36
31
28
35
28
rc=Ceiling reflectance, rw=Wall reflectance, RCR=Room cavity ratio
CU Data Based on 20% Effective Floor Cavity Reflectance.
38
34
31
27
37
34
31
27
30
26
7
8
9
10
Specifications and Dimensions subject to change without notice.
Portfolio • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
ADP050103
09/27/2013 5:20:53 PM
Download