PORTFOLIO DESCRIPTION A very low brightness 6" diameter downlight for use with PAR30 short neck lamps (75W max). The precisely formed non-imaging reflector ensures 45° cutoff to lamp and lamp image. The modular housing system supports various downlight, wallwash, and lens reflectors. Type Catalog # Project Date Comments Prepared by SPECIFICATION FEATURES A ... Reflector/Baffle Positive reflector mounting pulls trim tight to ceiling. 0.050" spun aluminum reflector. Available in a variety of Alzak® finishes. Painted white finish as well as white or black baffles. B ... Trim Ring Self flanged or molded white trim ring. Metal trim ring and rimless trim ring accessories available (see Options and Accessories). C ... Socket Cap One piece heat dissipating die-cast aluminum. D ... Housing Precision die-cast aluminum 1-1/2" (38mm) deep collar. Optical assembly adjusts within the housing to accommodate ceilings up to 4 1/4" (108mm) thick. H ... Socket Medium base porcelain socket with nickel plated screw shell. E ... Universal Mounting Bracket Accepts 1/2" EMT, C Channel, T bar fasteners and hanger bars. Provides 5" total adjustment. Insulation Detector Self-resetting insulation detector opens circuit if insulation is improperly installed. F ... Conduit Fittings Die-cast screw tight connectors. G ... Junction Box U.L. listed for four in, four out #12 at 90°C pull through branch wiring. Pry-outs for four 1/2" and two 3/4" conduits. Access to junction box by removing reflector. Labels cULus listed, C.S.A. certified, damp location. Options & Accessories TRM=Metal Trim Rings to replace molded trim ring. TRR=Rimless Trim Rings for minimal flange appearance in plaster ceilings. HD6 6301/6300 75W MAX PAR30 6" DOWNLIGHT F C H D 9 13/16" [249mm] E G Optional Step Down Transformer Top View A 13 5/8" [346mm] 11 1/8" [282mm] 5 11/16" [144mm] 6 3/8" [162mm] 7 1/4" [184mm] NOTES: B Accessories should be ordered separately. For additional options, please consult your Cooper Lighting Representative. Alzak is a registered trademark of Aluminum Company of America. ORDERING INFORMATION Sample Number: Complete unit consists of housing, ballast and trim. Housing HD6=6'' Incandescent Options CP=Chicago Plenum Trims 6301=Self Flanged Reflector 6300=Molded Trim Ring Finish B=Specular Black G=Specular Gold GP=Graphite Option WF=White Painted Flanged (Self Flanged only) Derated Wattage Label DR*=DeRated, Specify Wattage GPH=Graphite Haze H=Semi-Specular Clear LI=Specular Clear W=Gloss White WH=Wheat WHH=Wheat Haze Accessories H277=Step Down Transformer, 300VA Max HB26=C Channel Bar Hangers, 26" Long, Pair HB50=C Channel Bar Hangers, 50" Long, Pair TRM6=Metal Trim Ring, Specify Finish TRR6=Rimless Trim Ring, White FK5=5 Amp Field Installable Fuse Kit 300V Max RMB-22=Wood Joist Bar Hanger, 22" Long, Pair HSA6=Slope Adapter for 6" Aperture Housings, Specify Slope WMH=Warm Haze BB=Black Baffle (6300 only) WB=White Baffle (6300 only) Specifications and Dimensions subject to change without notice. Consult your representative for additional options and finishes. ADV985074 09/27/2013 5:36:32 PM HD6 6301/6300 PHOTOMETRICS Test No. H22245 HD6-6300C Lamp=75W PAR30 Halogen Flood Lumens=1100 Spacing Criteria=0.6 Efficiency=89.2% 550 1100 1650 Average Luminance Candlepower Candlepower Distribution 2200 Deg. 0 5 15 25 CD 2732 2454 2035 341 35 45 55 65 75 85 90 43 10 0 0 0 0 0 Deg. CD/SQ M 45 55 65 75 85 862 0 0 0 0 Initial Nadir Footcandles 5'6" 6'6" 8'0" Beam Diameter 3'6" 4'0" 5'0" 90 65 43 27 19 14 6'6" 8'0" 9'0" Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot. Footcandle values are initial, apply appropriate light loss factors where necessary. Zonal Lumen Summary 0-60 0-90 90-180 0-180 Distance to Illuminated Plane 10'0" 12'0" 14'0" 2750 Zone 0-30 0-40 Cone of Light Lumens 948 976 982 982 0 982 %Lamp 86.2 88.8 Coefficient of Utilization %Luminaire 96.6 99.5 89.2 89.2 0.0 89.2 100.0 100.0 0.0 100.0 Test No. H22246 HD6-6300C Lamp=75W PAR30 Halogen Narrow Spot Lumens=1100 Spacing Criteria=0.2 Efficiency=96.5% 8100 10800 50% 30% 10% 0% 30 10 50 30 10 50 10 50 10 50 10 0 106 103 106 102 106 100 106 99 104 100 104 98 104 97 99 96 99 94 95 93 95 91 91 90 91 89 89 87 2 3 4 5 101 98 96 94 98 95 92 89 95 92 89 86 93 90 87 84 96 94 91 88 94 91 88 86 92 89 86 84 94 92 89 87 91 88 85 83 91 90 88 86 89 87 84 82 89 88 86 85 87 85 84 82 86 84 83 81 6 7 8 9 92 90 88 86 87 85 83 81 84 82 80 78 82 80 78 76 87 84 82 80 84 81 79 78 82 79 77 76 85 83 82 80 81 79 77 75 84 83 81 79 81 79 77 75 83 82 80 79 80 78 77 75 79 78 76 74 84 79 76 74 79 76 74 78 74 rc=Ceiling reflectance, rw=Wall reflectance, RCR=Room cavity ratio CU Data Based on 20% Effective Floor Cavity Reflectance. 78 74 77 73 73 Average Luminance Candlepower Candlepower Distribution 5400 70 70% 50 10 2700 80% rc rw RCR 0 1 Deg. 0 5 15 CD 13561 6260 1534 25 35 45 128 13 4 55 65 75 85 90 0 0 0 0 0 Deg. CD/SQ M 45 55 65 75 604 0 0 0 85 0 Cone of Light Distance to Illuminated Plane Initial Nadir Footcandles Beam Diameter 5'6" 448 1'0" 6'6" 8'0" 10'0" 12'0" 14'0" 321 212 136 1'6" 1'6" 2'0" 2'6" 3'0" 94 69 Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot. 13500 Footcandle values are initial, apply appropriate light loss factors where necessary. Zonal Lumen Summary Zone 0-30 Lumens 1051 0-40 0-60 0-90 90-180 0-180 1058 1062 1062 0 1062 %Lamp 95.5 96.2 96.5 96.5 0.0 96.5 Coefficient of Utilization %Luminaire 99.0 99.7 100.0 100.0 0.0 100.0 80% rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 70 70% 50% 30% 10% 0% 50 30 10 50 30 10 50 10 50 10 50 10 0 115 112 110 108 115 110 107 104 115 109 105 102 115 108 103 100 112 108 105 103 112 107 103 101 112 106 102 99 107 105 102 101 107 103 100 97 103 101 100 99 103 100 98 96 99 98 97 97 99 97 96 95 97 95 94 94 106 104 102 101 99 98 96 102 100 96 96 95 93 92 99 97 94 94 92 91 90 97 95 92 92 90 89 88 101 99 97 96 94 93 92 98 96 95 93 92 91 89 96 94 93 91 90 89 88 99 97 96 95 94 92 91 95 94 92 91 90 89 88 97 96 95 94 93 92 91 94 93 92 91 89 88 87 96 95 94 93 92 91 90 93 92 91 90 89 88 87 92 91 91 89 88 88 87 rc=Ceiling reflectance, rw=Wall reflectance, RCR=Room cavity ratio CU Data Based on 20% Effective Floor Cavity Reflectance. Specifications and Dimensions subject to change without notice. Portfolio • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801 ADV985074 09/27/2013 5:36:32 PM