Catalog # Type

advertisement
PORTFOLIO
DESCRIPTION
A very low brightness 6" diameter downlight for use with PAR30 short neck
lamps (75W max). The precisely formed non-imaging reflector ensures 45°
cutoff to lamp and lamp image. The modular housing system supports
various downlight, wallwash, and lens reflectors.
Type
Catalog #
Project
Date
Comments
Prepared by
SPECIFICATION FEATURES
A ... Reflector/Baffle
Positive reflector mounting pulls
trim tight to ceiling. 0.050" spun
aluminum reflector. Available in a
variety of Alzak® finishes. Painted
white finish as well as white or
black baffles.
B ... Trim Ring
Self flanged or molded white trim
ring. Metal trim ring and rimless
trim ring accessories available (see
Options and Accessories).
C ... Socket Cap
One piece heat dissipating die-cast
aluminum.
D ... Housing
Precision die-cast aluminum
1-1/2" (38mm) deep collar.
Optical assembly adjusts within
the housing to accommodate
ceilings up to 4 1/4" (108mm) thick.
H ... Socket
Medium base porcelain socket with
nickel plated screw shell.
E ... Universal Mounting
Bracket
Accepts 1/2" EMT, C Channel, T bar
fasteners and hanger bars.
Provides 5" total adjustment.
Insulation Detector
Self-resetting insulation detector
opens circuit if insulation is
improperly installed.
F ... Conduit Fittings
Die-cast screw tight connectors.
G ... Junction Box
U.L. listed for four in, four out #12
at 90°C pull through branch wiring.
Pry-outs for four 1/2" and two 3/4"
conduits. Access to junction box by
removing reflector.
Labels
cULus listed, C.S.A. certified, damp
location.
Options & Accessories
TRM=Metal Trim Rings to replace
molded trim ring.
TRR=Rimless Trim Rings for
minimal flange appearance in
plaster ceilings.
HD6
6301/6300
75W MAX
PAR30
6" DOWNLIGHT
F
C
H
D
9 13/16"
[249mm]
E
G
Optional Step Down
Transformer
Top View
A
13 5/8"
[346mm]
11 1/8"
[282mm]
5 11/16"
[144mm]
6 3/8"
[162mm]
7 1/4"
[184mm]
NOTES:
B
Accessories should be ordered
separately. For additional options,
please consult your Cooper Lighting
Representative. Alzak is a registered
trademark of Aluminum Company
of America.
ORDERING INFORMATION
Sample Number: Complete unit consists of housing, ballast and trim.
Housing
HD6=6''
Incandescent
Options
CP=Chicago
Plenum
Trims
6301=Self Flanged
Reflector
6300=Molded Trim Ring
Finish
B=Specular Black
G=Specular Gold
GP=Graphite
Option
WF=White Painted
Flanged (Self
Flanged only)
Derated
Wattage Label
DR*=DeRated,
Specify
Wattage
GPH=Graphite Haze
H=Semi-Specular Clear
LI=Specular Clear
W=Gloss White
WH=Wheat
WHH=Wheat Haze
Accessories
H277=Step Down Transformer, 300VA Max
HB26=C Channel Bar Hangers, 26" Long, Pair
HB50=C Channel Bar Hangers, 50" Long, Pair
TRM6=Metal Trim Ring, Specify Finish
TRR6=Rimless Trim Ring, White
FK5=5 Amp Field Installable Fuse Kit 300V Max
RMB-22=Wood Joist Bar Hanger, 22" Long, Pair
HSA6=Slope Adapter for 6" Aperture Housings, Specify
Slope
WMH=Warm Haze
BB=Black Baffle (6300 only)
WB=White Baffle (6300 only)
Specifications and Dimensions subject to change without notice.
Consult your representative for additional options and finishes.
ADV985074
09/27/2013 5:36:32 PM
HD6 6301/6300
PHOTOMETRICS
Test No. H22245
HD6-6300C
Lamp=75W
PAR30
Halogen
Flood
Lumens=1100
Spacing Criteria=0.6
Efficiency=89.2%
550
1100
1650
Average Luminance
Candlepower
Candlepower Distribution
2200
Deg.
0
5
15
25
CD
2732
2454
2035
341
35
45
55
65
75
85
90
43
10
0
0
0
0
0
Deg.
CD/SQ M
45
55
65
75
85
862
0
0
0
0
Initial Nadir
Footcandles
5'6"
6'6"
8'0"
Beam
Diameter
3'6"
4'0"
5'0"
90
65
43
27
19
14
6'6"
8'0"
9'0"
Beam diameter is to 50% of maximum footcandles, rounded
to the nearest half-foot.
Footcandle values are initial, apply appropriate light loss factors where necessary.
Zonal Lumen Summary
0-60
0-90
90-180
0-180
Distance to
Illuminated Plane
10'0"
12'0"
14'0"
2750
Zone
0-30
0-40
Cone of Light
Lumens
948
976
982
982
0
982
%Lamp
86.2
88.8
Coefficient of Utilization
%Luminaire
96.6
99.5
89.2
89.2
0.0
89.2
100.0
100.0
0.0
100.0
Test No. H22246
HD6-6300C
Lamp=75W
PAR30
Halogen
Narrow
Spot
Lumens=1100
Spacing Criteria=0.2
Efficiency=96.5%
8100
10800
50%
30%
10%
0%
30
10
50
30
10
50
10
50
10
50
10
0
106
103
106
102
106
100
106
99
104
100
104
98
104
97
99
96
99
94
95
93
95
91
91
90
91
89
89
87
2
3
4
5
101
98
96
94
98
95
92
89
95
92
89
86
93
90
87
84
96
94
91
88
94
91
88
86
92
89
86
84
94
92
89
87
91
88
85
83
91
90
88
86
89
87
84
82
89
88
86
85
87
85
84
82
86
84
83
81
6
7
8
9
92
90
88
86
87
85
83
81
84
82
80
78
82
80
78
76
87
84
82
80
84
81
79
78
82
79
77
76
85
83
82
80
81
79
77
75
84
83
81
79
81
79
77
75
83
82
80
79
80
78
77
75
79
78
76
74
84
79
76
74
79
76
74
78
74
rc=Ceiling reflectance, rw=Wall reflectance, RCR=Room cavity ratio
CU Data Based on 20% Effective Floor Cavity Reflectance.
78
74
77
73
73
Average Luminance
Candlepower
Candlepower Distribution
5400
70
70%
50
10
2700
80%
rc
rw
RCR
0
1
Deg.
0
5
15
CD
13561
6260
1534
25
35
45
128
13
4
55
65
75
85
90
0
0
0
0
0
Deg.
CD/SQ M
45
55
65
75
604
0
0
0
85
0
Cone of Light
Distance to
Illuminated Plane
Initial Nadir
Footcandles
Beam
Diameter
5'6"
448
1'0"
6'6"
8'0"
10'0"
12'0"
14'0"
321
212
136
1'6"
1'6"
2'0"
2'6"
3'0"
94
69
Beam diameter is to 50% of maximum footcandles, rounded
to the nearest half-foot.
13500
Footcandle values are initial, apply appropriate light loss factors where necessary.
Zonal Lumen Summary
Zone
0-30
Lumens
1051
0-40
0-60
0-90
90-180
0-180
1058
1062
1062
0
1062
%Lamp
95.5
96.2
96.5
96.5
0.0
96.5
Coefficient of Utilization
%Luminaire
99.0
99.7
100.0
100.0
0.0
100.0
80%
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
70
70%
50%
30%
10%
0%
50
30
10
50
30
10
50
10
50
10
50
10
0
115
112
110
108
115
110
107
104
115
109
105
102
115
108
103
100
112
108
105
103
112
107
103
101
112
106
102
99
107
105
102
101
107
103
100
97
103
101
100
99
103
100
98
96
99
98
97
97
99
97
96
95
97
95
94
94
106
104
102
101
99
98
96
102
100
96
96
95
93
92
99
97
94
94
92
91
90
97
95
92
92
90
89
88
101
99
97
96
94
93
92
98
96
95
93
92
91
89
96
94
93
91
90
89
88
99
97
96
95
94
92
91
95
94
92
91
90
89
88
97
96
95
94
93
92
91
94
93
92
91
89
88
87
96
95
94
93
92
91
90
93
92
91
90
89
88
87
92
91
91
89
88
88
87
rc=Ceiling reflectance, rw=Wall reflectance, RCR=Room cavity ratio
CU Data Based on 20% Effective Floor Cavity Reflectance.
Specifications and Dimensions subject to change without notice.
Portfolio • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
ADV985074
09/27/2013 5:36:32 PM
Download