HALO Commercial d esc r iption Catalog # Recessed 8 inch aperture open wall wash for one horizontal 26W double twin tube or 26/32/42W triple twin tube compact fluorescent lamp. Fixture is suitable for commercial construction. Insulation must be kept 3" from top and sides of housing. Universal input electronic ballast with dimming and emergency options. Type Project Comments Date Prepared by S P E C I F I C A T I O N feat u r es M ec h anica l Frame Boat shaped galvanized steel frame with 1/2" plaster lip accommodates ceilings up to 2" thick. May be used for new construction or remodeling installations. Provided with (2) remodel clips to secure frame when installed from below the ceiling. Trim Retention Reflector assembly is retained with two torsion springs and held tightly to the finished ceiling surface. Orientation markings on housing and trim facilitate proper alignment. E l ect r ica l Junction Box (6) 1/2" and (2) 3/4" trade size pry outs positioned to allow straight conduit runs. Listed for (12) #12 AWG (six in, six out) 90°C conductors and feed thru branch wiring. Mounting Brackets Bar hanger receivers adjusts 2" vertically from above the ceiling or thru the aperture. Use with No Fuss™ bar hangers or with Lamp Socket 1/2" EMT. Removable to facilitate 4-pin G24q base accepts (1) 26W installation from below the ceiling. DTT or 26/32/42W TTT lamp. No Fuss™ Bar Hangers Socket Housing Pre-installed and centered bar Galvanized steel socket housing hanger locks to tee grid with a attached securely to reflector screwdriver or pliers. Centering with captive thumbscrew. Vents marks on the bar hanger provide effective lamp thermal mechanism allows consistent management. positioning of fixtures. Control Gear O ptica l Universal 120V - 277V UNV or Reflector 347V input electronic ballast for Highly efficient one piece 26/32/42W compact fluorescent aluminum reflector combined with lamp. spun aluminum gradient kicker Emergency Battery Pack reflector provides for vertical REM – Remote emergency illumination with a downlight component. Equal cutoff on room test switch. Housing includes 120V/277V, 60Hz dual-tap battery side and uniform illumination pack provides 90 minutes of of the wall plane for a visually emergency illumination. Long life comfortable optic. Self flanged maintenance free sealed nickel standard. cadmium batteries recharge fully -Specular Reflectors - Polished in 24 hours. REM configuration flange standard with white includes prewired and attached painted flange option. remote test switch plate and -Baffles and White Reflector - indicator light. REM option White painted flange is the standard emergency standard. configuration, and is compatible with all standard reflector options, ordered separately. Emergency Battery Pack - Average Lamp Lumen Ratings REM option: 26W 425lm, 32W 600lm, 42W 750lm (Note: average lamp lumens are based upon REM manufacturer ratings. Delivered lumens depend upon trim; refer to trim photometry to factor delivered lumens). Code Compliance - Thermally protected and cULus listed for damp locations. -IP20 rated for open trims - NFPA Life Safety (Emergency Battery Pack). - EMI/RFI per FCC Title 47 CFR, Part 18, non consumer limits. -Peel down wattage label from 42W to 32W and 26W. Allows de-rating to set max. relamp wattage per project specifications (multi-wattage housings only). -DR - De-rated label housings are wattage specific for 26/32W or 26W. PD8H142 82HWW (1) 26W DTT 26/32/42W TTT Compact Fluorescent 8-Inch Aperture Open Wall Wash New Construction or Remodel Non-IC - High efficacy luminaire may be used to meet IECC, ASHRAE, and Title 24 commercial standards. ADV111712 January 10, 2013 9:15 AM HALO Commercial PD8H142 82HWW E N E R G Y D ATA PD8H142E, PD8CPH142E PD8H1423E Min. Starting Temp -5°F / -20°C Sound Rating Class A EMI/RFI Emissions FCC 47CFR Part 18 Non-Consumer Limits Input Frequency 50/60 Hz Power Factor > 0.98 THD < 10% Input Voltage 120V - 277V ±10% Crest factor < 1.7 UL Listed Class P, Type 1 Outdoor, CSA or C/UL Certified Operating Frequency > 40kHz Input Power 28W CFQ26W/G24Q Input Current 0.50A @ 120V Crest factor < 1.6 Input Power 31W CFTR26W/GX24Q Input Current 0.50A @ 120V Ballast factor 1.02 Crest factor < 1.6 Ballast factor 1.00 Input Power 36W CFTR32W/GX24Q Input Current 0.50A @ 120V Input Current 0.11A @ 347V Ballast factor 0.98 Input Current 0.22A @ 277V Crest factor < 1.5 Ballast factor .98 Input Power 50W CFTR42W/GX24Q Input Current 0.50A @ 120V Input Current 0.22A @ 277V Input Current 0.15A @ 347V Ballast factor 1.00 Crest factor < 1.5 Ballast factor .96 DIMENSIONS 5.850" [148.59 mm] 8.375" I.D. [212.73mm] 9.250" [234.95mm] 9.750" O.D [247.65mm] 26.400" [670.56mm] 9.472" [240.59mm] 16.181" [410.99mm] www.cooperlighting.com Input Current 0.09A @ 347V Input Current 0.22A @ 277V Input Power 45W CFTR42W/GX24Q Ballast factor 1.02 Ballast factor 1.00 Input Power 35W CFTR32W/GX24Q Input Current 0.09A @ 347V CFQ26W/G24Q Input Current 0.22A @ 277V Input Power 28W CFTR26W/GX24Q Min. Starting Temp 0°F / -18°C Sound Rating Class A EMI/RFI Emissions FCC 47CFR Part 18 Non-Consumer Limits Input Frequency 60 Hz Power Factor > 0.98 THD < 10% Input Voltage 347VAC ±10% cULus Listed Class P, Type 1 Outdoor, Type CC Operating Frequency 50-60 kHz Input Power 31W HALO Commercial PD8H142 82HWW O r d e r ing info r mation SAMPLE NUMBER: : PD8H142E 82HWWC O r d e r h o u s i n g , r e fl e c t o r a n d l a m p s e p a r a t e l y f o r a c o m p l e t e l u m i n a i r e . Finish Option C=Specular Clear G=Specular Gold H=Semi Specular Clear W=White (White Flange) Reflector 82HWW = 8” horizontal open wall wash Housing Multi-Wattage PD8H142 = 8 Inch horizontal (1) 26/32/42W DTT/TTT CFL PD8CPH142 = 8 Inch horizontal (1) 26/32/42W DTT/TTT CFL, CCEA listed (Chicago Plenum) Flange Option Blank=Polished Flange (C, G, H) Blank=White flange (W) WF=White Flange (C, G, H Reflectors) De-Rated Label PD8H132 = 8 Inch horizontal (1) 26/32W DTT/TTT CFL PD8CPH132 = 8 Inch horizontal (1) 26/32W DTT/TTT CFL, CCEA listed (Chicago Plenum) PD8H126 = 8 Inch horizontal (1) 26W DTT/TTT CFL PD8CPH126 = 8 Inch horizontal (1) 26W DTT/TTT CFL, CCEA listed (Chicago Plenum) Accessories HB128APK = L channel hanger bar, 26”, ‘No-Fuss’, pair (replacement) RMB22 = 22” long wood joist mounting bars Ballast Option E = 120V – 277V 50/60Hz UNV REM = 120V/277V 60Hz dual-tap emergency battery ballast with remote test switch plate 3E = 347V, 50/60Hz 1DMARKX = 5% two-wire (26/32/42W) dimming, 120V 2DMARKX = 5% two-wire (26/32/42W) dimming, 277V EDMARK7 = 5% 0-10V discrete two-wire (26/32/42W) dimming, 120-277V 1DMARKXREM = 5% two-wire (26/32/42W) dimming, 120V; with REM emergency option 2DMARKXREM = 5% two-wire (26/32/42W) dimming, 277V; with REM emergency option EDMARK7REM = 5% 0-10V discrete two-wire (26/32/42W) dimming, 120-277V; with REM emergency option P H OTO M E T RY PD8H142E-82HWWC_32TTT Candela Distribution Spacing Criteria = 1.50 Lumens per Watt = 51 LpW Test No. P31434 Test Model: PD8H142E-82HWWC_32TTT Candlepower Distribution Curve 90° 80° 70° 60° 50° 40° 10° Zone Degree Candela 0* 548 5 532 45 13903 15 550 55 10676 25 559 65 5872 35 558 75 2903 45 425 85 308 55 282 65 126 75 46 85 3 90 0 Avg. 0° Luminance Lumens % Lamp % Fixture 0-30 640.02 26.70 38.00 0-40 1067.21 44.50 63.40 0-60 1598.97 66.60 95.00 0-90 1682.45 70.10 100.00 *CBCP 30° 0° Zonal Lumen Summary Luminance (Average Candela/M2) Degrees Vertical 20° Single Unit Footcandles Multiple Unit Footcandles 2.5' from wall Multiple Unit Footcandles 2.5' from wall (distance from fixture along wall) 2.5' from wall (spacing between fixtures) (spacing between fixtures) 3 4 1 4.3 3.5 1.4 0.5 1 12.3 10.7 12.3 1 14.5 16.2 14.5 2 21.7 15.9 6.7 2.0 2 30.0 31.0 30.0 2 36.6 40.8 36.6 3 24.0 19.7 12.3 5.7 3 27.5 30.2 27.5 3 33.0 35.3 33.0 4 17.3 15.0 11.5 6.6 4 20.4 23.0 20.4 4 23.9 24.9 23.9 5 10.7 10.2 8.8 6.3 5 13.9 16.2 13.9 5 15.7 16.5 15.7 10.1 6 6.2 6.6 6.4 5.1 6 9.3 10.8 9.3 6 10.1 10.4 7 3.8 4.1 4.4 4.0 7 6.5 7.1 6.5 7 6.7 6.8 6.7 8 2.6 2.9 3.0 3.0 8 4.8 5.0 4.8 8 4.7 4.9 4.7 9 1.9 2.1 2.2 2.2 9 3.5 3.7 3.5 9 3.5 3.6 3.5 10 1.5 1.6 1.6 1.6 10 2.7 2.8 2.7 10 2.7 2.0 2.7 Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot. Footcandle values are initial, apply appropriate light loss factors where necessary. Note: Specifications and Dimensions subject to change without notice. Visit our web site at www.cooperlighting.com Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 486.4801 www.cooperlighting.com Cooper Lighting 5925 McLaughlin Rd. Mississauga, Ontario, Canada L5R 1B8 905.507.4000 FAX 905.568.7049