INSTALLATION INSTRUCTIONS
V90040 REV G
Avoid Fire or Electric Shock
QUIET CEILING SQUARE TRIM
QCT901, QCM510 BASED SERIES
Page 1 of 3
*Installation Instructions for qualified electricians only.
*Install per National Electrical Code and local regulations.
*Read Installation Instructions completely before installation.
*Failure to follow Installation Instructions may void warranties.
THIS PRODUCT MUST BE INSTALLED IN
ACCORDANCE WITH THE APPLICABLE
INSTALLATION CODE BY A PERSON
FAMILIAR WITH THE CONSTRUCTION AND
OPERATION OF THE PRODUCT AND THE
HAZARDS INVOLVED.
8.
Fixture Mounting:
Butterfly Mounting (Commerical):
1.
Fixture comes equipped with Universal Mounting brackets and
can take common 1 inch or 1-1/2 inch Black Iron or Galvanized
Mounting Channels (Supplied By Others).See Fig.1.
2.
Position Fixture so the Mounting Channels lie on top of ceiling
runners.
3.
Fasten Mounting Channels securely to ceiling runners.
4.
Secure Mounting channels to Universal Butterfly Mounting
Brackets with wire tire downs.
5.
Adjust elevation of Fixture so Mudding Ring Edge will be flush
with surface of finished Ceiling by loosening two (2) 1/4 inch
Hex Screws on both Universal Mounting Brackets. See Fig. 1.
6.
Tighten two (2) 1/4 inch Hex Screws on both Universal
Butterfly Mounting Brackets to secure Fixture. See Fig. 1.
Hanger Bar Mounting (Residential):
7.
Adjustable hanger bars are preassembled with mounting
bracket and provided with fixture.The preassembled hanger
bars must attached to the fixture prior to installation.Aligh with
two screws on end of fixture and tighten .Hanger bars are
installed in Fig.1.
Fixture Cover Housing
Bracket
Mounting Channel
(Supply by Others)
Hanger bars can be used with grid ceilings having T
bars and joist installations of wood.Adjustable hanger
bars are for use in installations with spacing from 10" to 24",
while maintaining minimum 1/2" spacing around fixture
For 10" Spacing,the hanger bar can be shorten by breaking
them at score line as shown in Fig.2.
Grid Ceiling Installation (Figure 3):
Step 1 Extend bar hangers between the T bars and slide the slots
in the mounting tabs over the T-bars.
Step 2 Adjust housing platform position by sliding back and
forth on bar hangers to desired position. Housing may be locked
in the position by tightening bar hanger locking screws on
housing platform.See Detail 3A.
Joist Installation (Figure 4):
Step 1 Extend bar hangers to fit between joist and position
mounting tab locater lip tight to bottom of joist or framing
member. Bar hangers should be level with bottom of joist
or framing member.
Step 2 Attach bar hangers to joist or framing member using
appropriate hardware for material.
Step 3 Adjust housing platform position by sliding back and
forth on bar hangers to desired position. Housing may be locked
into position See Detail 3A.Nail Supplied in hanger bars will be
suitable.
Score Lines
10"
Universal Butterfly
Mounting Bracket
1/4" Hex Screw
Hanger Bars
Safety Cable
Mudding Ring
Trim Mechanism
Figure 1
Figure 2
INSTALLATION INSTRUCTIONS
V90040 REV G
Avoid Fire or Electric Shock
QUIET CEILING SQUARE TRIM
QCT901, QCM510 BASED SERIES
Page 2 of 3
*Installation Instructions for qualified electricians only.
*Install per National Electrical Code and local regulations.
*Read Installation Instructions completely before installation.
*Failure to follow Installation Instructions may void warranties.
THIS PRODUCT MUST BE INSTALLED IN
ACCORDANCE WITH THE APPLICABLE
INSTALLATION CODE BY A PERSON
FAMILIAR WITH THE CONSTRUCTION AND
OPERATION OF THE PRODUCT AND THE
HAZARDS INVOLVED.
Rotational Adjustment Ring
Lock Knob
Mudding Ring
Optional
Fixture
Mudding Frame
Bracket
Flathead Screw
"T"
Ceiling
Screw
Figure 3
Drywall Tape
Fixture Gap
Mudding Compound
Ball Detent Catch
Trim Mechanism
Figure 5
9.
Mudding Ring is sent unmounted from factory.
Adjust Mudding Ring to applicable Ceiling thickness by
aligning and securing to Fixture using applicable Mounting
Hole Pattern as indicated by Ceiling Thickness Indicator Mark
imprinted on Mudding Ring. See Fig.6.
10.
Secure Mudding Ring using four (4) #8-32 x 1/2 inch Flat
head Screws (for 1/2 inch, 5/8 inch and 3/4 inch Ceiling thickness)
or four (4) #8-32 x 3/4 inch Flat head Screws (for 1 inch Ceiling
thickness).
11.
Install Ceiling drywall up to Mudding Ring on Fixture so that the two
(2) Mudding Frame Brackets contact inside of Ceiling. See Fig. 5.
12.
Retain Fixture to Ceiling with one (1) Flathead Screw
through each of two (2) Mudding Frame Brackets.See Fig. 5
13.
Apply Drywall Tape and Mudding Compound to Mudding
frame overlapping Mudding frame, Flathead Screws, Fixture
Gap and surrounding area. Feather out Mudding Compound
from Mudding Ring opening to surrounding ceiling area to
produce a smooth, flat finish. See Fig. 5.
DETAIL 3A
DETAIL 4A
Figure 4
INSTALLATION INSTRUCTIONS
V90040 REV G
QUIET CEILING SQUARE TRIM
QCT901, QCM510 BASED SERIES
Avoid Fire or Electric Shock
Page 3 of 3
THIS PRODUCT MUST BE INSTALLED IN
ACCORDANCE WITH THE APPLICABLE
INSTALLATION CODE BY A PERSON
FAMILIAR WITH THE CONSTRUCTION AND
OPERATION OF THE PRODUCT AND THE
HAZARDS INVOLVED.
*Installation Instructions for qualified electricians only.
*Install per National Electrical Code and local regulations.
*Read Installation Instructions completely before installation.
*Failure to follow Installation Instructions may void warranties.
Mudding Frame
Window/Ceiling
Thickness Mark
5/8"
#8-32 Flat Head
Screw
Figure 6
Trim Installation:
17.
Connect Safety Cable attached to Trim to Fixture by inserting Safety
Cable through opening in Fixture and inserting Snap Hook
(See Fig. 1) on end of Safety Cable into hole in Bracket attached to
inside of fixture.
18.
Install Trim Mechanism into fixrue by pressing firmly to seat ball
detent catches. See Fig.5.