SERIES 75 INSTALLATION MANUAL Figure 1 STEP 1. Mount wall angle as shown in Figure 1. Angles must be mounted level and true for fixtures to mount correctly WALL ANGLE PROVIDED IN 8” SECTIONS CUT LAST SECTION TO FIT AVAILABLE SPACE FINISHED CEILING 8'(TYPICAL) 1/4" Figure 2 · NOTE “A” Use tie-wire (by others) to secure and level fixture housings to structure. Based on field dimension pre-cut 4 ft aluminum housing to fit, using hand-saw. STEP 1. Attach housing to wall angle. Support housing to structure with tie-wire. 90° OUTSIDE CORNER · NOTE “B” Last housing of run is aluminum, to be field cut by installing contractor. · For packing purposes, JOINING PLATE aligning clips and spacer blades are mounted at end of housing as shown in detail “A”. STEP 2. Install fixture from left to right, beginning with larger housing to smaller. Aluminum housing should be installed on right end of the run. STEP 3. Join fixture using joining plates. STEP 4. Align fixture using aligning clips. Re-positioning clevis brackets may be required after cutting aluminum housings · When installing housings, spacer blades will maintain a proper opening. ALUMINUM HOUSING · Prior to housing installation, reposition spacer blades and aligning clips shown in detail “B”. STEEL HOUSING CLEVIS BRACKET ALIGNER CLIPS (SEE DETAIL “B”) · Prior to installing shielding element, remove and discard spacer blades for all shielding elements except S72 bold baffle. SPACER BLADE Series 75R Installation Manual, Page 1 of 2 100 Andrews Rd., Hicksville, NY 11801 • Phone: 516-470-1000 • Fax: 516-470-1077 • http://www.neoray-lighting.com A B SERIES 75 INSTALLATION MANUAL Figure 3 LIGHTING STRIPS INSTALLATION (SEE DETAILS A & B) STEP 1. Remove lighting strips covers DETAIL A CHASE NIPPLE STEP 2. Install lighting strips into fixtures (attach to clevis bracket) TOP VIEW STEP 3. Attach first strip to outside power feed STEP 4. Through wire all strips STEP 5. Attach lighting strip covers to lighting strips STEP 6. Install shielding STEP 7. Install End Closure/End Plate DETAIL B CLEVIS BRACKET FLEXIBLE CONDUIT (NOT BY NEO-RAY) ADJUSTABLE STRIP LIGHT STRIP STAGGERED STRIP a) 3" STAGGER FOR T8 LAMP b) 6" STAGGER FOR T5 OR T5HO LAMP END CLOSURE (FLAT) LIGHT STRIP COVER END PLATE (FLANGED) Typical Plan View (Schematic) TIE-WIRE NOT BY NEO-RAY WORK FROM LEFT TO RIGHT WHEN FACING WALL. END CLOSURE STEEL HOUSING LAST HOUSING OF RUN IS FABRICATED OF ALUMINUM TO BE FIELD CUT BY INSTALLING CONTRACTOR. ALUMINUM HOUSING 3 15/16" 90° INSIDE CORNER ADJUSTABLE LIGHT STRIP (I.C.) 90° OUTSIDE CORNER (O.C.) 6" WALL RAIL FINISH: BLACK CEILING TILE BY OTHERS 3/8" 1/4" 3 3/16" 135° INSIDE CORNER (I.C.) 135° OUTSIDE CORNER (O.C.) 5/8"±1/8" 4 7/8"±1/8" END PLATE Series 75R Installation Manual, Page 2 of 2 100 Andrews Rd., Hicksville, NY 11801 • Phone: 516-470-1000 • Fax: 516-470-1077 • http://www.neoray-lighting.com