SERIES 75 INSTALLATION MANUAL
Figure 1
STEP 1.
Mount wall angle as shown in Figure 1.
Angles must be mounted level and true for fixtures to mount correctly
WALL ANGLE PROVIDED
IN 8” SECTIONS
CUT LAST SECTION TO
FIT AVAILABLE SPACE
FINISHED CEILING
8'(TYPICAL)
1/4"
Figure 2
· NOTE “A”
Use tie-wire (by others) to secure and level
fixture housings to structure.
Based on field dimension pre-cut 4 ft
aluminum housing to fit, using hand-saw.
STEP 1.
Attach housing to
wall angle. Support
housing to structure
with tie-wire.
90° OUTSIDE
CORNER
· NOTE “B”
Last housing of run is
aluminum, to be field cut by
installing contractor.
· For packing purposes,
JOINING PLATE
aligning clips and spacer
blades are mounted at end
of housing as shown in
detail “A”.
STEP 2.
Install fixture from
left to right,
beginning with
larger housing to
smaller. Aluminum
housing should be
installed on right
end of the run.
STEP 3.
Join fixture using
joining plates.
STEP 4.
Align fixture using
aligning clips.
Re-positioning clevis
brackets may be required
after cutting aluminum
housings
· When installing housings,
spacer blades will maintain
a proper opening.
ALUMINUM
HOUSING
· Prior to housing installation,
reposition spacer blades
and aligning clips shown in
detail “B”.
STEEL
HOUSING
CLEVIS BRACKET
ALIGNER CLIPS
(SEE DETAIL “B”)
· Prior to installing shielding
element, remove and
discard spacer blades for all
shielding elements except
S72 bold baffle.
SPACER BLADE
Series 75R Installation Manual, Page 1 of 2
100 Andrews Rd., Hicksville, NY 11801 • Phone: 516-470-1000 • Fax: 516-470-1077 • http://www.neoray-lighting.com
A
B
SERIES 75 INSTALLATION MANUAL
Figure 3
LIGHTING STRIPS INSTALLATION (SEE DETAILS A & B)
STEP 1. Remove lighting strips covers
DETAIL A
CHASE NIPPLE
STEP 2. Install lighting strips into fixtures (attach to clevis bracket)
TOP VIEW
STEP 3. Attach first strip to outside power feed
STEP 4. Through wire all strips
STEP 5. Attach lighting strip covers to lighting strips
STEP 6. Install shielding
STEP 7. Install End Closure/End Plate
DETAIL B
CLEVIS BRACKET
FLEXIBLE CONDUIT
(NOT BY NEO-RAY)
ADJUSTABLE STRIP
LIGHT STRIP
STAGGERED STRIP
a) 3" STAGGER FOR T8 LAMP
b) 6" STAGGER FOR T5 OR T5HO LAMP
END CLOSURE (FLAT)
LIGHT STRIP COVER
END PLATE (FLANGED)
Typical Plan View
(Schematic)
TIE-WIRE
NOT BY NEO-RAY
WORK FROM LEFT TO
RIGHT WHEN FACING WALL.
END CLOSURE
STEEL HOUSING
LAST HOUSING OF RUN IS FABRICATED OF ALUMINUM
TO BE FIELD CUT BY INSTALLING CONTRACTOR.
ALUMINUM HOUSING
3 15/16"
90° INSIDE CORNER
ADJUSTABLE
LIGHT STRIP
(I.C.)
90° OUTSIDE CORNER
(O.C.)
6"
WALL RAIL
FINISH: BLACK
CEILING TILE
BY OTHERS
3/8"
1/4"
3 3/16"
135° INSIDE CORNER
(I.C.)
135° OUTSIDE CORNER
(O.C.)
5/8"±1/8"
4 7/8"±1/8"
END PLATE
Series 75R Installation Manual, Page 2 of 2