Metalux D ES C R IPTION The Paralux IV Hard Metric Series is designed for hard metric (600mm x 1200mm) ceiling grids only. May not be used with 2' x 4' grids. Lamp is longer than ceiling grid and overhangs at one end. Row mounting more than two fixture per row cannot be done. The luminaire incorporates a 102mm precision cell louver into a nominal 168mm deep para-contoured fixture housing creating a high comfort parabolic optical assembly for optimum performance. The high comfort luminaire is designed to provide a superior visual environment plus the higher shielding louver angle offers excellent cut-off. Excellent choice for commercial office spaces, schools, hospitals or retail merchandising areas. Type Catalog # Project Date Comments Prepared by SPE C IFIC A TION FEA T U R E S C on s t r u c t i o n Nominal 168mm deep, paracontoured housing, die formed code gauge, prime cold rolled steel. Die embossed housing has full length die formed stiffeners for added strength. Contoured ballast/ wireway cover, easily removed without tools. Die formed captive lampholder bracket fully encloses lampholder wiring permitting easy lampholder replacement. Heavy end plates, securely attached with interlocking tabs and screws. Four auxiliary fixture end suspension points provided. KOs for continuous row wiring. Housing features enable fixture to be converted from Grid to T-option or vice versa in the field.* E le ctrica l* * Ballast are CBM/ETL Class “P” and are positively secured by mounting bolts. Pressure lock lampholders. UL/CUL listed. Suitable for damp locations. F in ish Lighting grade, baked white enamel finish. Multistage, iron phosphate pretreatment ensures maximum bonding and rust inhibition. Positive cam action spring loaded, self locking, black steel latches. Safety lock T-hinges allow hinging and latching either side. Louver Die formed of semi-specular, vertical grain, aluminum. Finish is anodic oxide coating. Accurate precision parabolic cells are held in place with interlocking feature. True-cut mitered corners. Black reveal with integral mechanical light seal around entire perimeter of louver. Louver protected from construction contaminants by polyethylene cover. H M -2 P GAX 328T8 332 Hin g in g /L a tch ing 18 Cell [168mm] 600MM X 1200MM PARABOLIC 3 T8 LAMPS SEMI-SPECULAR LOUVER Paralux IV Recessed Air Supply Troffer 594mm MOUNTING D A TA SID E V IE W Access Plate 22mm K.O. (2) 22mm K.O. (4) ENERGY DATA 1219mm Input Watts: EB Ballast & STD Lamps 328T8 (67), 332 (81) 168mm 38mm Luminaire Efficacy Rating LER = FP-57 Catalog Number: 2PGAX-332 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.19 603mm 1194mm L A MP CONF IGURA T IONS 133mm 95mm 196mm 1219mm *Convertibility applies to housing only. Appropriate shielding media assemblies must be utilized. 168mm 102mm X X X=178mm **Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements. 594mm C EILING C OM PA TA BI L I T Y G Grid/Lay-in Standard T Concealed T T Slot Grid F Aluminum Flange Trim With Supporting Swing Gates MZ Modular Trim With Supporting Swing Gates Ceiling Type Trim Type Exposed Grid Concealed T Slot Grid Flange Concealed “T” or ”Z“ Metal Pan G G or T G or T F MZ MZ (Verify compatibility/ consult Pre Sales Technical Support.) LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS Safe and convenient means of disconnecting power. ADF020538 2015-10-22 11:11:15 PH OTOM ETR IC S 2PGAX-332S36I Energy Saving Ballast F32T8/35K lamps 2900 lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.5 x mounting height Efficiency 66.4% Test Report: 2PGX332S36I.IES LER = FP-57 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.19 Luminance Data Average 0-Deg cd/sm 3247 2670 852 203 75 Angle in Deg 45 55 65 75 85 Average 45-Deg cd/sm 4075 2719 786 178 38 Average 90-Deg cd/sm 3966 2813 833 210 38 Catalog Description Candela Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 2259 2240 2189 2123 2040 1943 1831 1705 1561 1396 1194 931 566 219 70 32 15 4 0 Across ⊥ 2259 2260 2295 2355 2406 2435 2539 2460 2069 1705 1307 981 642 214 77 33 13 2 0 45° 2259 2247 2234 2224 2213 2190 2146 2097 2039 1752 1314 948 574 202 64 28 11 2 0 Coefficients of Utilization rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 79 74 68 63 58 54 50 46 43 40 38 79 71 64 57 51 46 42 38 35 32 29 79 69 60 53 46 41 36 33 30 27 24 79 67 57 49 42 37 33 29 26 23 21 77 72 67 62 57 53 49 45 42 39 37 77 70 63 56 50 46 41 38 34 32 29 77 68 59 52 46 41 36 32 29 27 24 77 66 56 49 42 37 32 29 26 23 21 20% 50% 50 30 10 30% 50 30 10 10% 50 30 10 0% 0 74 67 60 54 49 44 40 37 33 31 28 71 65 58 53 47 43 39 36 33 30 28 68 62 56 51 46 42 38 35 32 29 27 66 59 52 45 39 34 30 27 24 22 20 74 66 58 51 45 40 36 32 29 26 24 74 64 55 48 42 36 32 29 26 23 21 71 63 56 50 44 39 35 32 29 26 24 71 62 54 47 41 36 32 28 26 23 21 Zonal Lumen Summary Ty p i c a l VC P Pe r c e n t a g e s Zone 0-30 0-40 0-60 0-90 0-180 Room Size (Ft.) 20 x 20 30 x 30 30 x 60 60 x 30 60 x 60 Lumens 1857 3163 5293 5576 5576 H M -2 P GAX A D D IT IONA L H A RD ME T RIC SIZ E CONF IGURA T IONS %Lamp 22.1 37.7 63.0 66.4 66.4 %Fixture 33.3 56.7 94.9 100.0 100.0 Height Along 8.5’ 10.0’ 85 79 89 85 91 87 89 87 91 89 68 61 55 48 43 38 34 31 28 26 24 68 60 53 46 40 36 32 28 25 23 21 Height Across 8.5’ 10.0’ 84 79 89 85 91 86 89 86 90 87 Cells (Config.) Nominal Size Nominal Dimensional (mm) Size (mm) L W H HM-PGAX-132, 232 6, (1 row x 6 cells) 1x4 300x1200 1194 294 194 HM-PGAX-132, 232 8, (1 row x 8 cells) 1x4 300x1200 1194 294 194 HM-PGAX-132, 232 9, (1row x 9 cells) 1x4 300x1200 1194 294 194 HM-PGAX-232 12, (2 rows x 6 cells) 1x4 300x1200 1194 294 194 HM-PGAX-232 16, (2 rows x 8 cells) 1x4 300x1200 1194 294 194 HM-PGAX-232 18, (2 rows x 9 cells) 1x4 300x1200 1194 294 194 HM-2PGAX-2U6T8 6, (2 rows x 3 cells) 2x2 600x600 594 594 168 HM-2PGAX-2U6T8 9, (3 rows x 3 cells) 2x2 600x600 594 594 168 HM-2PGAX-2U1-5/8 9, (3 rows x 3 cells) 2x2 600x600 594 594 168 HM-2PGAX-3U1-5/8 9, (3 rows x 3 cells) 2x2 600x600 594 594 168 HM-2PGAX-2BX40 9, (3 rows x 3 cells) 2x2 600x600 594 594 168 HM-2PGAX-3BX40 9, (3 rows x 3 cells) 2x2 600x600 594 594 168 HM-2PGAX-2U6T8 12, (3 rows x 4 cells) 2x2 600x600 594 594 168 HM-2PGAX-2U6T8 16, (4 rows x 4 cells) 2x2 600x600 594 594 168 HM-2PGAX-232 12, (2 rows x 6 cells) 2x4 600x1200 1194 594 168 HM-2PGAX-232 16, (2 rows x 8 cells) 2x4 600x1200 1194 594 168 HM-2PGAX-232 18, (2 rows x 9 cells) 2x4 600x1200 1194 594 168 HM-2PGAX-332 18, (3 rows x 6 cells) 2x4 600x1200 1194 594 168 HM-2PGAX-332 24, (3 rows x 8 cells) 2x4 600x1200 1194 594 168 HM-2PGAX-332 27, (3 rows x 9 cells) 2x4 600x1200 1194 594 168 HM-2PGAX-432 24, (4 rows x 6 cells) 2x4 600x1200 1194 594 168 HM-2PGAX-432 32, (4 rows x 8 cells) 2x4 600x1200 1194 594 168 HM-2PGAX-432 36, (4 rows x 9 cells) 2x4 600x1200 1194 594 168 HM-PGAX2024-2U3 6, (2 rows x 3 cells) 20x24 500x600 594 494 168 HM-PGAX2024-2U3 9, (3 rows x 3 cells) 20x24 500x600 594 494 168 HM-PGAX2024-2U3 12, (3 rows x 4 cells) 20x24 500x600 594 494 168 HM-PGAX2048-232 12, (2 rows x 6 cells) 20x48 500x1200 1194 494 168 HM-PGAX2048-232 16, (2 rows x 6 cells) 20x48 500x1200 1194 494 168 HM-PGAX2048-232 18, (2 rows x 9 cells) 20x48 500x1200 1194 494 168 HM-PGAX2048-332 18, (2 rows x 9 cells) 20x48 500x1200 1194 494 168 HM-PGAX2048-332 24, (3 rows x 8 cells) 20x48 500x1200 1194 494 168 HM-PGAX2048-332 27, (3 rows x 9 cells) 20x48 500x1200 1194 494 168 HM-PGAX2048-432 24, (4 rows x 6 cells 20x48 500x1200 1194 494 168 HM-PGAX2048-432 32, (4 rows x 8 cells) 20x48 500x1200 1194 494 168 HM-PGAX2048-432 36, (4 rows x 9 cells) 20x48 500x1200 1194 494 168 HM-2PGAX-232 (2+2) 6, (2 rows x 3 cells) 2x4 600x1200 1194 594 168 168 HM-2PGAX-332 (2+2) 9, (3x3 cells) 2x4 600x1200 1194 594 HM-2PGAX-332 (2+2) 12, (3x4 cells) 2x4 600x1200 1194 594 168 HM-2PGAX-432 (2+2) 16, (4 rows x 4 cells) 2x4 600x1200 1194 594 168 1 For complete individual product information refer to appropriate specification data sheet. Nominal size for reference only. Hard Metric and standard size fixtures are not interchangeable. Additional configurations may be available. Consult Pre Sales Technical Support for specific requirements. 2 3 ORDER ING INFOR M A TION SAMPLE NUMBER: HM-2PGAX-332S36I-120V-EB81-U Voltage (5) 120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-277 (6) Number of Lamps 3= 3 Lamps (4) Rating Blank= Standard ATW-SW4= Chicago Rated Wattage 28T8=28W T8 (48") 32=32W T8 (48") Hard Metric HM=Hard Metric (1) Heat Removal HR=Heat Removal HRDO=Heat Removal Damper Open HRDC=Heat Removal Damper Closed Width 2=2' Width P=Paralux IV Trim Type (2) G=Grid/Lay-in – Standard T=Concealed T /Slot (3) F=Aluminum Flange Trim (7) MZ=Modular Trim Air Supply AX=Air Supply Floating Louver X=Blank Side/Floating Louver Non-Air Supply AVX=Air Supply Floating Louver with Directional Air Vane Louver Color S=Silver W=White Cell Configuration 36=3 Rows of 6, 18 Cell (2'x4') Louver Finish I=Semi-Specular/Haze (Low Iridescent) Standard MI=Specular/Mirrored (Low Iridescent) P=Painted Option – Aluminum Flange Trim (7) Blank=SW (Single White) Type Color ‘S’ Single ‘N’ Natural ‘R’ In Row ‘W’ White ‘E’ End of Row Options GL=Single Element Fuse GM=Double Element Fuse WTR=White Reveal Flex=Flex Installed (Reference Flex ordering information) EL=Emergency Installed Lamps Installed Blank=No Lamps Installed L8835=T8 Lamp, 28W and 32W, 3500K L8841=T8 Lamp, 28W and 32W, 4100K L8835HL=T8 Lamp, 32W, 3500K, 3100 Lumens L8841HL=T8 Lamp, 32W, 4100K, 3100 Lumens (1) NOTES: Integral End Plate Grid Lock feature not available in Heat Removal. (2) Convertibility applies to housing only, appropriate shielding media assemblies (3) must be utilized. Fixture also adaptable with flanged or modular trims. An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per fixture. (4) (5) Standard off-center ballast on 3-lamp fixtures. Products also available in non-US (6) voltages and frequencies for international markets. Not available when specifying (7) emergencies, voltage must be specific. Specify row configuration, type in catalog number when ordering complete fixture. Ballast Type EB8 =T8 Electronic Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 EB8 /PLUS= T8 Electronic Start. Total Harmonic Distortion < 10% No. of High Ballast Factor >1.15 Ballast 1, 2 or 3 Options PAF=Painted After Fabrication REP=Riveted Endplates Packaging U=Unit Pack PAL=Job Pack, out of carton PALC=Job Pack, in carton ER8 =T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 High Performance T8 Ballasts HB8 =T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Standard Ballast Factor .86 – .88 HB8 L=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Low Ballast Factor .77 – .82 HB8 N=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Normal Ballast Factor 1.0 HB8 H=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. High Ballast Factor 1.15 – 1.20 HR8 T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Standard Ballast Factor .86 – .88 HR8 DIM=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Step Dimming. Ballast Factor .88 HR8 L=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Low Ballast Factor .71 – .79 HR8 H=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. High Ballast Factor 1.15 – 1.20 ACCESSORIES SH IP P ING D A T A EQ-CLIP-U=T-BAR Safety Earthquake Clips (3) Catalog No. HM-2PGAX-332S36I Wt. 42 lbs. For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting Specifications and dimensions subject to change without notice. ADF020538 2015-10-22 11:11:15