COOPER LIGHTING - METALUX ® DESCRIPTION The 2HP2-IC is an energy saving solution for a multitude of applications. It uses a high performance T8 system that can save up to 40% of energy costs when compared to standard 3-lamp, 18-cell parabolics. The 2HP2-IC incorporates a 2" precision formed louver into a deep pre-painted housing. This combination creates a soft, even distribution while delivering a highly efficient T8 luminaire. The luminaire is compatible with all of today’s popular ceiling systems and is Type IC rated for installations when the housing will be in direct contact with insulation. The 2HP2-IC series is an excellent choice for commercial office spaces, schools, hospitals or retail merchandising areas. Type Catalog # Project Date Comments Prepared by SPECIFICATION FEATURES Construction Die formed nominal 4-3/4" deep para-contoured housing made from code gauge, cold rolled steel. Housing features die formed stiffeners for added rigidity along with end plates that securely attach to housing via interlocking tabs. Other housing features include a Grid to T-option (or vice versa) that allows you to do a conversion in the field. End plates also have an integral GridLock feature for safety and convenience. A contoured ballast/ wireway cover rests in the center of the housing and can be easily removed without tools, while die formed captive lamp holders encloses lampholder wiring for easy lampholder replacement. E l e c t r i c a l ** Ballasts are CBM/ETL Class “P” are positively secured by mounting bolts. Pressure lock lampholders. UL/CUL listed for Type IC Recessed Luminaire (Rated for direct contact with insulation). Suitable for damp locations. Finish High reflectance white pre- painted (standard). Multistage, iron phosphate pretreatment ensures maximum bonding and rust inhibition. H i n g i n g / L a t ch i n g Positive cam action spring loaded, self locking, black steel latches with safety lock T-hinges allow hinging and latching from either side. Louver Die formed high reflectance white aluminum (standard). Silver with semi-specular finish (optional). Accurate precision parabolic cells are held in place by interlocking feature. True-cut mitered corners. Black reveal with mechanical light seal around entire perimeter of louver. Louver protected by polyethylene cover. 2HP2-IC 217 317 2U1-5/8 3U1-5/8 Controls Fifth Light ballast options are offered for both 0-10V continuous dimming and DALI applications. Combine with energy-saving products like occupancy sensors, daylighting controls, and lighting relay panels from Cooper Controls (www.coopercontrol.com) to maximize energy savings. 6, 9 Cell 2' X 2' PARABOLIC 2 OR 3 LAMP HIGH PERFORMANCE T8 4-3/4" [121mm] FOR USE IN INSULATED CEILINGS 23-3/4" [603mm] MOUNTING DATA 2 LAMP 7/8" [22mm] K.O. (2) LAMP CONFIGURATIONS Access Plate 7/8" [22mm] K.O. (2) 3 LAMP 7/8" [22mm] K.O. (4) Access Plate 7/8" [22mm] (2) 2 LAMP – 6 CELL 4-3/4" [121mm] 2" [51mm] 23-3/4" [603mm] 23-3/4" [603mm] 10-3/16" [259mm] 23-3/4" [603mm] 3 LAMP – 9 CELL Input Watts: 4-3/4" [121mm] 3-5/8" [93mm] 3-5/8" [93mm] 1-3/4" [45mm] 6-7/8" [176mm] 1-3/4" [45mm] 2" [51mm] 6-7/8" [176mm] 7" 7" [178mm] [178mm] 23-3/4" [603mm] 24" [608mm] 24" [608mm] G Concealed T G Slot Grid F Aluminum Flange Trim With Supporting Swing Gates MZ Modular Trim With Supporting Swing Gates Ceiling Type Trim Type Exposed Grid Concealed T Slot Grid Flange Concealed “T” or ”Z“ Metal Pan G G G F MZ MZ (Verify compatibility/ consult factory.) COOPER LIGHTING HB Ballast & STD Lamps 217 (31), 317 (45), 2U1-5/8 (54), 3U1-5/8 (81) **Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements. CEILING COMPATIBILITY G Grid/Lay-in Standard ENERGY DATA LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS Safe and convenient means of disconnecting power. ADF110358 2HP2-IC 2x2 ORDERING INFORMATION Sample Number: 2HP2GX-IC-217W23P-UNV-HB81H-U Rating Blank=Standard NY=New York City Rated ATW-SW4=Chicago Rated Heat Removal HR =Heat Removal Cell Configuration 23 =2 Rows of 3, 6 Cell (2'x4') 33 =3 Rows of 3, 9 Cell (2'x4') Louver Finish I = Semi-Specular/ Haze(Low Iridescent) (Silver Only) P = Painted White (Standard) 1 Width 2 =2' Width Series HP2=High Performance 2” Paralux Louver 4 Option Aluminum Flange Trim Blank=SW (Single White) SN=Single, Natural Finish RN=In Row, Natural Finish RW=In Row, White Finish EN=End of Row, Natural Finish EW=End of Row, White Finish Trim Type G =Grid/Lay-in Standard G=Concealed T / Slot Grid 2 F =Aluminum 4 Flange Trim MZ =Modular Trim Voltage 5 120V = 120 Volt 277V = 277 Volt 347V = 347 Volt UNV = Universal Voltage 120-277 Air Supply AX=Air Supply Floating Louver X=Blank Side/Floating Louver - Non Air Supply AVX=Air Supply Floating Louver w/Directional Air Vane 6 Option GL = Single Element Fuse GM = Double Element Fuse WTR= White Reveal Lamps = Lamps Installed (refer to lamp ordering) Flex = Flex Installed (Reference Flex ordering information) EL = Emergency Installed 7 Type IC=IC Rated Number of Lamps 2=2 Lamps 3=3 Lamps 8 Wattage U1-5/8=31W T5 (24") 10 17=17W T8 (24") 9 11 0-10V Dimming Ballasts 5LTV8 =T8 0-10V Program Rapid Start. Total Harmonic Distortion < 10%. Ballast Factor 0.87 14 5LTVS8 =T8 0-10V Spec Grade Program Rapid Start. Total Harmonic Distortion < 10%. Ballast Factor 0.87 12, 13 Fifth Light DALI Ballasts 9 5LT8 = T8 DALI Program Rapid Start. Total Harmonic Distortion < 10%. Ballast Factor 1.0 Number of Ballasts 1=1 Ballast 2=2 Ballast Louver Color S=Silver W=White Notes: 1 2 3 4 5 6 7 8 Ballast Type High Performance T8 Ballasts HB8 =T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Standard Ballast Factor .86 – .88 HB8 L=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Low Ballast Factor .77 – .82 HB8 N=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Normal Ballast Factor 1.0 HB8 H=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. High Ballast Factor 1.15 – 1.20 HR8 T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Standard Ballast Factor .86 – .88 HR8 DIM=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Step Dimming. Ballast Factor .88 HR8 L=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Low Ballast Factor .71 – .79 HR8 H=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. High Ballast Factor 1.15 – 1.20 Integral End Plate Grid Lock feature not available in Heat Removal Louver is recessed by 5/16" in Concealed T or Slot Grid T. An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per fixture. Specify row configuration, type in catalog number when ordering complete fixtures. Products also available in non-US voltage and frequencies for international markets Not available when specifying emergencies, voltage must be specific Fixtures equipped with "EL" option may require a 5-1/2" housing depth. If installing in field, must use low profile battery pack. Standard off-center ballast on 3-lamp fixtures. For a complete listing of Fifthlight Technology products and other solutions from Cooper Controls, visit www.coopercontrol.com 10 Fifthlight ballast option not available. 11 0-10V ballast do not include DALI feature. Please select DALI ballast for use with Fifth Light system. 12 Specification grade 0-10V dimming ballast are NEMA premium and CEE listed. They are compatible with low mercury and energy saving lamps. 13 Specification Grade 0-10V ballast not offered in 3 or 4-lamp versions. 14 Standard 0-10V ballast not offered in 3 or 4-lamp versions Options RIF1 = Radio Interference Suppressor REP = Riveted End Plates Packaging U=Unit Pack PAL=Job Pack, out of carton PALC=Job Pack, in carton AC C E S S O R I E S EQ-CLIP-U=T-BAR Safety Earthquake Clips 3 Note: An EQ Grid Clip is recommended for all 9/16” ceiling systems. Four required per fixture. SHIPPING DATA Catalog No. 2HP2-IC-217W23P Wt. 28 lbs. Visit our web site at www.cooperlighting.com 4/13 ADF110358 Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801