COOPER LIGHTING - METALUX

advertisement
COOPER LIGHTING - METALUX
D ES C R IPTION
The ArcLine 1' x 4' Series features a deep para-contoured fixture housing,
high reflectivity and optimum lamp to lens spacing. The series produces
total uniformity of light in the luminous area and is compatible with all of
today’s popular ceiling systems and is available with a number of options
and accessories for application versatility.
®
Type
Catalog #
Project
Date
Comments
The specification luminaire is designed to offer maximum efficiency and
performance for today’s unique interior specifications. The ArcLine Series
is an excellent choice for commercial office spaces, schools, hospitals or
retail merchandising areas.
Prepared by
SPE C IFIC A TION FEA T U R E S
C on s t r u c t i o n
E le ctrica l*
Frame/Shielding
5-5/8" deep, para-contoured
housing, die formed code gauge,
prime cold rolled steel. Die
embossed housing has full length
die formed stiffeners for added
strength. Ballast/ wireway cover
easily removed without tools.
Die formed captive lampholder
bracket fully encloses lamp-holder
wiring permitting easy lampholder
replacement. Heavy endplates are
securely attached with interlocking
tabs and screws. Four auxiliary
fixture end suspension points
provided. KOs for continuous row
wiring. Endplates have integral
Grid-Lock feature for safety and
convenience.
Ballasts are CBM/ETL Class “P” and
are positively secured by mounting
bolts. Pressure lock lampholders.
UL/CUL listed. Suitable for damp
locations.**
Die formed heavy gauge, flat,
steel door with reinforced mitered
corners and paint after fabrication,
baked matte white enamel finish.
Quadrasealed to prevent light
spillage. Frosted acrylic profile
lenses provide a soft but effective
distribution of light.
F in ish
Multistage, iron phosphate
pretreatment ensures maximum
bonding and rust inhibitor. Lighting
grade, baked white enamel finish.
Hin g in g /L a tch ing
Positive cam action steel latches
with baked white enamel finish.
Safety-lock T-hinges allow hinging
and latching either side. Door
assembly hinges down for easy
access from below without tools.
Controls
Fifth Light ballast options are
offered for both 0-10V continuous
dimming and DALI applications.
Combine with energysaving
products like occupancy sensors,
daylighting controls, and lighting
relay panels from Cooper Controls
(www.coopercontrol.com) to
maximize energy savings.
ALN
128T5
228T5
154T5
254T5
1' X 4' TROFFER
1 OR 2 T5 LAMPS
Specification Architectural
Troffer
5-5/8"
[143mm]
11-9/16" [294mm]
MO UNTING D A TA
D OOR F RA ME S
Access Plate
7/8" [22mm] K.O. (2)
1-1/2"
[38mm]
7/8" [22mm] K.O. (2)
AL N
F lat, White
Steel
11-3/4"
[298mm]
ENERGY DATA
5-1/4" [133mm]
3-1/2" [89mm]
Input Watts:
EB Ballast & STD Lamps
128T5 (31), 228T5 (62),
154T5 (62), 254T5 (117)
6-1/4" [159mm]
48" [1219mm]
L A M P C ONFIGUR A TI O N S
1 LAMP
2 LAMP
5-5/8"
[143mm]
5-5/8"
[143mm]
11-9/16"
[294mm]
X=3-1/4"
[83mm]
*Reference the lamp/ballast data in the
Technical Section for specific lamp/ballast
requirements.
**Consult Pre Sales Technical Support.
X
11-9/16"
[294mm]
CEI LING C OM PA TIB I L I T Y
G
Grid/Lay-in
Standard
G
Concealed T
G
Slot Grid
F
Aluminum Flange Trim
With Supporting
Swing Gates
Ceiling
Type
Trim
Type
Exposed Grid
Concealed T
Slot Grid
Flange
G
G
G
F
LAMPS CONTAIN MERCURY. DISPOSE ACCORDING
TO LOCAL, STATE OR FEDERAL LAWS
(Verify compatibility/ consult
Pre Sales Technical Support.)
Safe and convenient means of
disconnecting power.
ADF111821
2014-06-02 14:51:16
ALN T 5
PH OTOM ETR IC S
ALN-154T5-UNVEBT1-U
Electronic Ballast
(1) F54W-T5-835 Lamp
4800 Lumens
Spacing criterion:
(II) 1.2 x mounting
height, (⊥) 1.3 x
mounting height
Efficiency 64.4%
Test Report: ALN154T5-UNV-EBT1-U.IES
LER = FL105
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $2.29
Along II
1182
1178
1160
1126
1079
1019
953
875
785
694
603
512
419
332
250
173
106
47
0
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
45°
1182
1173
1157
1128
1089
1038
978
906
821
730
630
536
440
348
263
189
115
48
0
Across ⊥
1182
1178
1164
1140
1105
1061
999
924
832
734
631
530
428
340
256
176
103
44
0
C o e f fi c i e n t s o f U t i l i z a t i o n
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
77
67
59
52
46
41
37
34
31
28
26
77
65
55
47
41
36
32
28
26
23
21
77
62
51
43
36
31
28
24
22
20
18
75
68
62
57
52
48
45
41
39
36
34
75
66
58
51
45
41
37
33
31
28
26
75
63
54
46
40
35
31
28
25
23
21
75
61
50
42
36
31
27
24
22
20
18
50%
50 30 10
30%
50 30 10
10%
50 30 10
0%
0
72
63
55
49
44
39
36
32
30
27
25
68
61
53
47
42
38
34
31
29
27
25
66
58
51
46
41
37
33
31
28
26
24
64
54
46
39
33
29
25
23
20
18
16
72
61
52
45
39
35
31
28
25
23
21
72
59
49
42
36
31
27
24
22
20
18
68
59
50
44
38
34
30
27
25
22
21
Luminance Data
Zone
0-30
0-40
0-60
0-90
0-180
Angle
in Deg
45
55
65
75
85
%Lamp
19.0
30.7
52.1
64.4
64.4
(2) F54W-T5-835-ECO
Lamps, 4800 Lumens
Spacing criterion:
(II) 1.2 x mounting
height, (⊥) 1.2 x
mounting height
Efficiency 60.6%
Test Report: ALN254T5-UNV-EBT1-U.IES
LER = FL56
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $4.29
20%
Zonal Lumen Summary
Lumens
910
1473
2502
3089
3089
Candlepower
Along II
2290
2280
2242
2175
2078
1976
1827
1680
1507
1325
1151
974
805
634
482
337
203
94
0
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
45°
2290
2272
2232
2168
2073
1959
1826
1674
1507
1342
1169
994
820
655
493
351
213
92
0
Across ⊥
2290
2279
2240
2171
2077
1956
1826
1676
1523
1351
1176
1001
824
659
491
349
210
84
0
C o e f fi c i e n t s o f U t i l i z a t i o n
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
77
70
64
59
54
49
46
42
40
37
35
ALN-254T5-UNVEBT1-U
Electronic Ballast
Candlepower
%Fixture
29.5
47.7
81.0
100.0
-100.0
Average
0-Deg
cd/sm
3633
3304
2908
2474
1996
68
57
48
41
35
31
27
24
21
19
18
Average
45-Deg
cd/sm
3822
3459
3048
2703
2039
Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com
66
57
49
43
37
33
30
27
24
22
0
66
56
47
40
35
30
27
24
21
19
18
Average
90-Deg
cd/sm
3843
3421
2978
2517
1869
Eaton’s Cooper Lighting Business
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.cooperlighting.com
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
72
66
60
55
51
47
43
40
37
35
33
72
63
55
49
43
39
35
32
29
27
25
72
61
51
44
38
34
30
27
24
22
20
72
58
48
40
34
30
26
23
21
19
17
70
64
59
54
49
45
42
39
36
34
32
70
62
54
48
43
38
35
31
29
26
24
70 70
60 57
51 47
43 40
38 34
33 29
30 26
26 23
24 21
22 19
20 17
20%
50%
50 30 10
30%
50 30 10
50
67
59
52
46
41
37
33
31
28
26
24
64
57
50
44
40
36
32
30
27
25
23
62
55
48
43
38
35
32
29
27
25
23
67
57
49
42
37
33
29
26
24
21
20
67
56
46
39
34
29
26
23
20
18
17
64
55
47
41
36
32
28
26
23
21
19
Zonal Lumen Summary
Luminance Data
Zone
0-30
0-40
0-60
0-90
0-180
Angle
in Deg
45
55
65
75
85
Lumens
1732
2780
4699
5813
5813
%Lamp
18.0
29.0
49.0
60.6
60.6
Specifications and
dimensions subject to
change without notice.
%Fixture
29.8
47.8
80.8
100.0
100.0
Average
0-Deg
cd/sm
6937
6286
5553
4820
3993
64
54
45
38
33
29
25
23
20
18
17
10%
30 10
Average
45-Deg
cd/sm
7026
6415
5737
5020
3908
62
54
46
40
35
31
28
25
23
21
19
0%
0
62
52
44
38
33
29
25
22
20
18
17
61
51
43
36
31
27
24
21
19
17
16
Average
90-Deg
cd/sm
7073
6460
5772
4992
3568
ADF111821
2014-06-02 14:51:16
ALN T 5
OR D ER ING INFOR M A TION
SAMPLE NUMBER: ALNG-228T5-UNV-EBT1-U
Rating
Blank=
Standard
ATW-SW4=
Chicago
Rated
Width
Blank=1' Width
Series
ALN=ArcLine Series
Trim Type
G=Grid/Lay-in –
Standard (1)
G=Concealed T
G=Slot Grid
F=Aluminum Flange Trim (4)
Number of
Lamps
1 or 2 lamps
Wattage (Length)
28T5=28W T5 (48")
54T5=54W T5HO (48")
Shielding
Blank=Smooth Frosted
Acrylic (Standard)
Option – Aluminum
Flange Trim (4)
Blank=SW (Single White)
Type
Color
‘S’ Single
‘N’ Natural
‘R’ In Row
‘W’ White
‘E’ End of Row
(1)
Voltage (2)
120V=120 Volt
277V=277 Volt
347V=347 Volt
UNV=Universal
Voltage 120-277 (3)
Options
GL=Single Element Fuse
GM=Double Element Fuse
Lamps=Lamps Installed
(see options and accessories)
Flex=Flex Installed
(Reference Flex ordering
information)
EL=Emergency Installed (6)
(2)
NOTES: An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per fixture. Products
(3)
also available in non-US voltages and frequencies for international markets. Not available when specifying
(4)
emergencies, voltage must be specific. Specify row configuration, type in catalog number when ordering
(5)
(6)
complete fixture. When utilizing 28W T8 lamps, HPT8 Ballast must be speficied. Must specify voltage (120(7)
(8)
277V) when selecting EL option. .90 and 1.15 ballast factor available for 2 28W T5 lamps only. Step Dimming
(9)
ballast available for 2 28W T5 lamps only. 1-Lamp step dimming ballast in a Normal Ballast factor not available.
(10)
(11)
1-Lamp ballast in a High Ballast factor not available.
For a complete
2-Lamp ballast will not operate 1-Lamp.
listing of Fifthlight Technology products and other solutions from Cooper Controls, visit www.coopercontrol.com.
(12)
(13)
0-10V ballast do not include DALI feature. Please select DALI ballast for use with Fifth Light system.
Specification
grade 0-10V dimming ballast are NEMA premium and CEE listed. They are compatible with low mercury and energy
saving lamps.
For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to
change without notice. Consult your Cooper Lighting Representative for availability and ordering information.
Ballast Type (2)
EBT =T5/T5HO Electronic Program Rapid Start.
Total Harmonic Distortion < 10%.
Standard Ballast Factor=1.0
Ballast/FactorType
EBT N=T5 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%.
Normal Ballast Factor=.90 (7)
EBT H=T5 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%.
High Ballast Factor=1.15 (7), (10)
EBT NDIM=T5 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%.
Step Dimming, Normal Ballast
Factor=.95-1.0 (8), (9)
EBT HDIM=T5 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%.
Step Dimming, High Ballast
Factor=1.15 (8)
Packaging
U=Unit Pack
PALC=Job Pack, in
carton
ACCESSORIES
EQ-CLIP-U=T-BAR Safety
Earthquake Clips(1)
F2M-14S-W-U=Field
Installed Flange Kit
0-10V Dimming Ballasts (12)
5LTV5 =T5 0-10V Program Rapid Start.
Total Harmonic Distortion < 10%.
Ballast Factor 1.0
5LTVS5 =T5 0-10V Spec Grade Program Rapid
Start. Total Harmonic Distortion < 10%.
Ballast Factor 1.0 (13)
5LTV5H =T5HO 0-10V Program Rapid Start.
Total Harmonic Distortion < 10%.
Ballast Factor 1.0
5LTVS5H =T5HO 0-10V Spec Grade Program
Rapid Start. Total Harmonic Distortion <
10%. Ballast Factor 1.0 (13)
Fifth Light DALI Ballasts (11)
5LT5 =T5 DALI Program Rapid Start.
Total Harmonic Distortion < 10%.
Ballast Factor 1.0
5LT5H =T5HO DALI Program Rapid Start.
Total Harmonic Distortion < 10%.
Ballast Factor 1.0
Number of Ballasts
1=1 Ballast
2=2 Ballasts
SH IP P ING D ATA
Catalog No.
ALNG-128T5
ALNG-228T5
ALNG-154T5
ALNG-254T5
Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com
Eaton’s Cooper Lighting Business
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.cooperlighting.com
Specifications and
dimensions subject to
change without notice.
Wt.
19 lbs.
19 lbs.
19 lbs.
19 lbs.
ADF111821
2014-06-02 14:51:16
Download