VERSYS INDIVIDUAL - ETG-STG Installation Manual STEP 1 - CEILING PREPARATION

advertisement
VERSYS INDIVIDUAL - ETG-STG Installation Manual
STEP 1 - CEILING PREPARATION
Figure 1
FIXTURE SLOT/OPENING
IN GRID CEILING SYSTEM
30
", 3
6
", 4
8
"O
R6
0"
CEILING TILES
6"
REMOVED CEILING TILES
A) GRID CENTERS TO BE 6"
(AS SHOWN IN FIGURE 2 AND FIGURE 3).
LENGTH OF GRID OPENING HAS TO BE ACCORDING
TO THE ORDERED FIXTURE OR FIXTURES RUNS.
B) BEFORE INSTALLING FIXTURES IN GRID CEILING
PLEASE REMOVE CEILING TILES NEXT TO FIXTURE
SLOT AS SHOWN IN FIGURE 1
Figure 2
Figure 3
6" OC
9/16” SLOT TEE GRID CEILING SYSTEM (STG)
VERSYS INDIVIDUAL ETG-STG Installation Manual, Page 1
6" OC
15/16” EXPOSED TEE GRID CEILING SYSTEM (ETG)
VERSYS INDIVIDUAL - ETG-STG Installation Manual
STEP 2 - FIXTURE PREPARATION
Figure 1
INSTALL "IND"* MARKED FIXTURE IN SLOT/OPENING PREPARED CEILING GRID
AND SECURE FOR PLENUM ACCORDING TO NEC, UL AND CITY CODES
BY TIE WIRES AS SHOWN IN FIGURE 3.
CEILING
TILE
"IND" FIXTURE
TIRE WIRE
(BY OTHERS)
DETAIL "A"
DETAIL "A"
Figure 2
Figure 3
IF USING "ETG"*
GRID CEILING SYSTEM
THIS TAB IS AS SHOWN
IN FIGURE 2.
IF USING FIXTURE
IN "STG"** GRID
CEILING SYSTEM
THIS TAB MUST BE
FOLDED OUT AS SHOWN
IN FIGURE 3.
* - "ETG" - 15/16" X 1 1/2" HIGH FLAT "T" GRID CEILING.
** - "STG" - 9/16" BOLT "T" X 1 11/16" HIGH SCREW SLOT GRID CEILING.
VERSYS INDIVIDUAL ETG-STG Installation Manual, Page 2
VERSYS INDIVIDUAL - ETG-STG Installation Manual
STEP 3 - POWERING INSTALLED FIXTURES
REMOVE ACCESS PLATE, ATTACH FEED WHIP
TO ACCESS PLATE AND CONNECT FIXTURE FEED
WIRES TO WHIP.
PUT BACK ACCESS PLATE ONTO FIXTURE.
FEED WHIP
(BY OTHERS)
ACCESS
PLATE
FEED WIRES
NOTE:
FOR DIMMING BALLAST ONLY
CUSTOMER HAS TO HAS KEEP LAMPS "ON" MINIMUM 100 HOURS
FOR PROPER FULL RANGE DIMMING AND LAMP STABILITY
VERSYS INDIVIDUAL ETG-STG Installation Manual, Page 3