NEO-RAY DESCRIPTION VERSYS with it's unique free floating lensed micro-louver breaks new ground in recessed ambient T5 fluorescent fixture design. This fixture combines innovation, aesthetics, performance and utility. VERSYS Continuous is a flexible modular system which can incorporate optional recessed downlights, daylight and motion sensors, sprinklers and return air via the utility modules which occur between the fluorescent lighting elements. Type Catalog # Project Date Comments Prepared by SPECIFICATION FEATURES Construction Aluminum extruded housing and formed steel reflector Shielding Composite floating louver consists of a semi-specular aluminum louver with .5" high cross blades on 1" centers, frosted acrylic side rails and injection molded end caps Electrical 120, 277, 347 or Universal Voltage electronic ballast. Fixtures and electrical components certified to UL and CUL standards Housing Lengths 30" nominal 36" nominal 48" nominal 60" nominal 96" nominal Finish Durable, 92% refelective, low gloss, white, powder coated finish Mounting Fully recessed in acoustic tile or sheetrock ceilings VERSYS CONTINUOUS 6 15⁄16" 1 T5HO Recessed Light Distribution: Direct = 100% 4 7⁄16" 4" 3⁄16" 9⁄16" 5 3⁄8" 6" ORDERING INFORMATION SAMPLE NUMBER: 1BR/1T5HO/4/UEB-STG-EM-GLR-BC-S42 1B Series 1B R 1 Mounting R=Recessed T5HO Lamp Type T5HO = T5HO Number of Lamps 1 = 1 Lamp Run Length BC Voltage Ballast 1 = 120V EB = Electronic ballast 2 = 277V DB = Dimming ballast1 3 = 347V U = Universal S42 Ceiling Type2 Fusing GLR = Fast blow fuse ETG = 15/16”W x 1½”H T-Grid GMF = Slow blow fuse STG = 9/16" W x 1¾”H Slot T-Grid Emergency SR = Sheetrock (Flanged) EM = BC = Blank Cover Plate3 FSR = Sheetrock (Flangeless) Emergency 1 Battery Pack Shielding S42 = Floating composite louver 1 - Specify manufacturer, catalog number 2 - Consult factory for other ceiling types 3 - All other utility module options quoted and ordered separately based upon plans and specifications Specifications and Dimensions subject to change without notice. Consult your representative for additional options and finishes. ADN090430 02/18/2010 11:17:44 AM THREE FIXTURE TYPES USED FOR CONTINUOUS RUN Intermediate (INT) Beginning of Run (BOR) Finished end with end plate and 2 ¾” snap-in cover End of Run (EOR) Open end, to be joined to next fixture Both ends open, to be joined to fixtures at both ends Finished end with end plate and 2 ¾” snap-in cover Open end, to be joined to next fixture CONTINUOUS JOINER DETAILS JOINERS UTILITY COMPARTMENT WIREWAY COVERS SNAP IN COVER SLIDING ALIGNER CONTINUOUS RUN DETAILS Typical Run using 5’ and 2½’ (30”) fixture modules 17’ 6’’ 5’ 5’ 5’ 2½’ (30”) BOR INT INT EOR Typical End Filler Typical End Filler Utility Modules. Nominally 6” x 6” CEILING MOUNTING DETAILS ROD Ø1/4" NOT BY NEO-RAY ETG 15/16” EXPOSED T- GRID STG 9/16” SLOT T-GRID SR SHEETROCK ROD Ø1/4" NOT BY NEO-RAY FSR FLANGELESS SHEETROCK Specifications and Dimensions subject to change without notice. Neo-Ray • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801 ADN090430 02/18/2010 11:17:44 AM PHOTOMETRICS 180° 0° 45° 90° 135° Coefficients of Utilization Candela Effective floor cavity reflectance rc 90° 0° 45° 1BR-1T5HO-4-UEB-S42 (1) FP39T5HO / 835 3500 Lumens Efficiency 70.4% Test Report #14685.0 80% 70 50 20% 50% 30 10 50 30 30% 10 50 30 10 Angle 0 5 Along II 1135 1157 45° 1135 1160 Across⊥ 1135 1163 rw RCR 0 .84 .84 .84 .84 .78 .78 .78 .75 .75 .75 10 15 1131 1117 1140 1131 1150 1148 1 2 .78 .76 .73 .71 .73 .68 .64 .61 .71. 69 .68 .64 .61 .59 .68 .67 .66 .62 .60 .57 20 25 1058 976 1074 990 1094 1023 3 4 .67 .61 .57 .53 .62 .55 .50 .46 .58 .54 .51 .53 .48 .45 .56 .53 .51 .58 .54 .51 30 35 883 824 899 837 926 827 5 6 7 8 9 .58 .53 .49 .46 .42 .48 .43 .39 .36 .32 .46 .42 .38 .35 .31 40 45 50 55 729 627 553 470 723 582 472 346 673 505 369 249 10 .39 .30 .25 .22. 60 65 70 75 376 299 229 165 232 159 105 69 178 121 62 42 80 85 90 92 28 0 38 17 0 29 15 0 .55 .45 .41 .37 .33 .44 .39 .35 .31 .28 .40 .35 .31 .28 .24 .43 .39 .34 .31 .27 .39 .35 .31 .27 .24 .29 .25 .21 Zonal Lumen Summary Zone Lumens %Lam %Fixture 0-30 0-40 892. 1413. 25.5 46.4 36.2 58.1 0-60 0-90 90-180 0-180 2176. 2464. 0 2464. 70.3 79.8 0 70.4 100.0 0 100.0 .42 .38 .34 .30 .27 .39 .35 .31 .27 .24 .29 .24 .21 88.1 Total Luminaire Efficiency = 70.4% STANDARD UTILITY MODULE Blank Blank cover plate is standard offering OPTIONS FOR UTILITY MODULE Downlight MR 16 20W = (1) 20W MR16 fixed downlights Daylight Sensor Motion Sensor FIre Sprinkler Air Return NOTE: Daylight sensors, motion sensors, and sprinklers not by Neo-Ray. Utility covers to accomodate the aforementioned equipment are available at additional cost. Specifications and Dimensions subject to change without notice. Neo-Ray • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801 ADN090430 02/18/2010 11:17:44 AM CONTINUOUS RUNS USING 4’ FIXTURE MODULES WITH 3’ BEGINNING AND/OR END OR RUN FIXTURE MODULES 8’ FIXTURE MODULE MATRIX WITH 3’ AND 4’ BEGINNING AND/OR END OR RUN FIXTURE MODULES Nominal Actual No. of 8’ No. of 3’ No. of 2’ Run Length Fixture Fixture Lamps Length Modules Modules 8’ 1 12’ 1 14’ 1 16’ 2 19’ 2 20’ 2 22’ 2 24’ 3 27’ 3 28’ 3 30’ 3 32’ 4 35’ 4 36’ 4 38’ 4 40’ 5 43’ 5 44’ 5 46’ 5 48’ 6 51’ 6 52’ 6 54’ 6 56’ 7 59’ 7 60’ 7 No. of 4’ Fixture Modules 1 2 2 1 1 1 2 2 1 1 1 2 2 1 1 1 2 2 1 1 2 1 1 1 2 2 1 1 1 Nominal Actual No. of 4’ No. of 3’ No. of 3’ No. of 2’ No. of Utility Run Length Fixture Lamps Fixture Lamps Compartments Modules Modules Length 7’ 1 1 1 1 1 2 1 3 2 8’ 2 2 0 0 1 2 3 10’ 1 1 2 2 2 4 3 11’ 2 2 1 1 2 4 4 12’ 3 3 0 0 2 5 4 14’ 2 2 2 2 3 4 5 15’ 3 3 1 1 3 6 5 16’ 4 4 0 0 3 6 6 18’ 3 3 2 2 4 7 6 19’ 4 4 1 1 4 6 7 20’ 5 5 0 0 4 8 7 22’ 4 4 2 2 5 8 8 23’ 5 5 1 1 5 9 8 24’ 6 6 0 0 5 9 26’ 5 5 2 2 6 10 9 27’ 6 6 1 1 6 10 10 28’ 7 7 0 0 6 11 10 30’ 6 6 2 2 7 10 11 31’ 7 7 1 1 7 12 11 32’ 8 8 0 0 7 12 12 34’ 7 7 2 2 8 13 12 35’ 8 8 1 1 8 12 13 36’ 9 9 0 0 8 14 13 38’ 8 8 2 2 9 14 14 39’ 9 9 1 1 9 13 14 40’ 10 10 0 0 9 8 1 2 No. of 3’ No. of Utility Lamps Compartments CONTINUOUS RUNS USING 5’ FIXTURE MODULES WITH 30” BEGINNING AND/OR END OR RUN FIXTURE MODULES CONTINUOUS RUNS USING 3’ FIXTURE MODULES Nominal Actual Run Length Length No. of Utility Compartments Nominal Actual No. of 5’ No. of 4’ No. of 30” Run Length Fixture Lamps Fixture Length Modules Modules No. of 3’ Fixture Modules No. of 2’ Lamps 6’ 2 2 1 9’ 3 3 2 12’ 4 4 3 15’ 5 5 4 18’ 6 6 5 21’ 7 7 6 24’ 8 8 7 27’ 9 9 8 30’ 10 10 9 33’ 11 11 10 36’ 12 12 11 39’ 13 13 12 42’ 14 14 13 45’ 15 15 14 48’ 16 16 15 51’ 17 17 16 54’ 18 18 17 57’ 19 19 18 55’ 11 11 57.5’ 11 11 60’ 20 20 19 60’ 12 12 0 No. of 2’ No. of Utility Lamps Compartments 7.5’ 1 1 1 1 10’ 2 2 0 0 1 1 12.5’ 2 2 1 1 2 15’ 3 3 0 0 2 17.5’ 3 3 1 1 3 20’ 4 4 0 0 3 22.5’ 4 4 1 1 4 25’ 5 5 0 0 4 27.5’ 5 5 1 1 5 30’ 6 6 0 0 5 32.5’ 6 6 1 1 6 35’ 7 7 0 0 6 37.5’ 7 7 1 1 7 40’ 8 8 0 0 7 42.5’ 8 8 1 1 8 45’ 9 9 0 0 8 47.5’ 9 9 1 1 9 50’ 10 10 0 0 9 52.5’ 10 10 1 1 10 0 0 10 1 1 11 0 11 Specifications and Dimensions subject to change without notice. Neo-Ray • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801 ADN090430 02/18/2010 11:17:44 AM