NEO-RAY DESCRIPTION VERSYS with it's unique free floating lensed micro-louver breaks new ground in recessed ambient T5 fluorescent fixture design. This fixture combines innovation, aesthetics, performance and utility. VERSYS Continuous is a flexible modular system which can incorporate optional recessed downlights, daylight and motion sensors, sprinklers return air via the utility modules which occur between the fluorescent lighting elements. Type Catalog # Project Date Comments Prepared by SPECIFICATION FEATURES Construction Aluminum extruded housing and formed steel reflector Shielding Composite floating louver consists of a semi-specular aluminum louver with .5" high cross blades on 1" centers with high transmission overlay, frosted acrylic side rails and injection molded end caps Electrical 120, 277, 347 or Universal Voltage electronic ballast. Fixtures and electrical components certified to UL and CUL standards Housing Lengths 30" nominal 36" nominal 48" nominal 60" nominal 96" nominal Finish Durable, 92% refelective, low gloss, white, powder coated finish Mounting Fully recessed in acoustic tile or sheetrock ceilings VERSYS CONTINUOUS 6 15⁄16" 1 T5 Recessed Light Distribution: Direct = 100% 4 7⁄16" 4" 3⁄16" 9⁄16" 5 3⁄8" 6" ORDERING INFORMATION SAMPLE NUMBER: 1BR/1T5/4/UEB-STG-EM-GLR-BC-S41 1B Series 1B R 1 Mounting R=Recessed T5 Lamp Type T5 = T5 Number of Lamps 1 = 1 Lamp Run Length S41 BC Voltage Ballast 1 = 120V EB = Electronic ballast 2 = 277V DB = Dimming ballast1 3 = 347V U = Universal Fusing Ceiling Type2 GLR = Fast blow fuse ETG = 15/16”W x 1½”H T-Grid GMF = Slow blow fuse STG = 9/16" W x 1¾”H Slot T-Grid Emergency SR = Sheetrock (Flanged) EM = BC = Blank Cover Plate3 FSR = Sheetrock (Flangeless) Emergency Battery Pack1 Shielding S41 = Floating louver with high transmission overlay 1 - Specify manufacturer, catalog number 2 - Consult factory for other ceiling types 3 - All other utility module options quoted and ordered separately based upon plans and specifications Specifications and Dimensions subject to change without notice. Consult your representative for additional options and finishes. ADN081971 02/18/2010 11:16:02 AM THREE FIXTURE TYPES USED FOR CONTINUOUS RUN Intermediate (INT) Beginning of Run (BOR) Finished end with end plate and 2 ¾” snap-in cover End of Run (EOR) Open end, to be joined to next fixture Both ends open, to be joined to fixtures at both ends Finished end with end plate and 2 ¾” snap-in cover Open end, to be joined to next fixture CONTINUOUS JOINER DETAILS JOINERS UTILITY COMPARTMENT WIREWAY COVERS SNAP IN COVER SLIDING ALIGNER CONTINUOUS RUN DETAILS Typical Run using 5’ and 2½’ (30”) fixture modules 17’ 6’’ 5’ 5’ 5’ 2½’ (30”) BOR INT INT EOR Typical End Filler Typical End Filler Utility Modules. Nominally 6” x 6” CEILING MOUNTING DETAILS ROD Ø1/4" NOT BY NEO-RAY ETG 15/16” EXPOSED T- GRID STG 9/16” SLOT T-GRID SR SHEETROCK ROD Ø1/4" NOT BY NEO-RAY FSR FLANGELESS SHEETROCK Specifications and Dimensions subject to change without notice. Neo-Ray • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801 ADN081971 02/18/2010 11:16:02 AM PHOTOMETRICS 180° 0° 45° 90° 135° Coefficients of Utilization Candela Effective floor cavity reflectance rc 90° 0° 45° 1BR-1T5-4-UEB-STG-S41 (1) FP21T5 / 835 2125 Lumens Efficiency 79.8% 70 50 20% 50% 30 10 50 30 30% 10 50 30 10 Angle 0 5 Along II 816 816 45° 816 821 Across⊥ 816 824 rw RCR 0 .95 .95 .95 .95 .89 .89 .89 .85 .85 .81 10 15 816 787 823 790 832 805 1 2 .89 .86 .83 .80 .82 .77 .73 .69 .81. 79 .77 .73 .70 .67 .78 .76 .74 .70 .68 .65 20 25 737 705 750 712 764 715 3 4 .76 .70 .64 .60 .71 .63 .57 .52 .66 .62 .58 .60 .55 .51 .64 .60 .57 .58 .54 .51 30 35 640 592 635 565 613 524 5 6 7 8 9 .65 .61 .56 .52 .48 .54 .49 .45 .41 .37 .53 .48 .44 .40 .36 40 45 50 55 520 456 396 330 463 386 306 229 405 309 214 149 10 .45 .35 .29 .25. 60 65 70 75 270 217 171 126 161 106 70 47 106 73 47 30 80 85 90 75 26 0 26 12 0 20 12 0 .57 .51 .47 .42 .38 .50 .45 .40 .36 .32 .46 .40 .36 .32 .28 .49 .44 .39 .35 .31 .45 .40 .36 .31 .28 .34 .28 .25 Zonal Lumen Summary Zone Lumens 0-30 0-40 632. 985. 29.8 46.4 37.3 58.1 1495. 1496. 0 1696. 70.3 79.8 0 79.8 100.0 0 100.0 0-60 0-90 90-180 0-180 Test Report #14493.0 80% %Lam %Fixture .48 .43 .39 .35 .31 .45 .40 .35 .31 .27 .33 .28 .25 88.1 Total Luminaire Efficiency = 79.8% STANDARD UTILITY MODULE Blank Blank cover plate is standard offering OPTIONS FOR UTILITY MODULE Downlight MR 16 20W = (1) 20W MR16 fixed downlights Daylight Sensor Motion Sensor FIre Sprinkler Air Return NOTE: Daylight sensors, motion sensors, and sprinklers not by Neo-Ray. Utility covers to accomodate the aforementioned equipment are available at additional cost. Specifications and Dimensions subject to change without notice. Neo-Ray • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801 ADN081971 02/18/2010 11:16:02 AM CONTINUOUS RUNS USING 4’ FIXTURE MODULES WITH 3’ BEGINNING AND/OR END OR RUN FIXTURE MODULES 8’ FIXTURE MODULE MATRIX WITH 3’ AND 4’ BEGINNING AND/OR END OR RUN FIXTURE MODULES Nominal Actual No. of 8’ No. of 3’ No. of 2’ Run Length Fixture Fixture Lamps Length Modules Modules 8’ 1 12’ 1 14’ 1 16’ 2 19’ 2 20’ 2 22’ 2 24’ 3 27’ 3 28’ 3 30’ 3 32’ 4 35’ 4 36’ 4 38’ 4 40’ 5 43’ 5 44’ 5 46’ 5 48’ 6 51’ 6 52’ 6 54’ 6 56’ 7 59’ 7 60’ 7 No. of 4’ Fixture Modules 1 2 2 1 1 1 2 2 1 1 1 2 2 1 1 1 2 2 1 1 2 1 1 1 2 2 1 1 1 Nominal Actual No. of 4’ No. of 3’ No. of 3’ No. of 2’ No. of Utility Run Length Fixture Lamps Fixture Lamps Compartments Modules Modules Length 7’ 1 1 1 1 1 2 1 3 2 8’ 2 2 0 0 1 2 3 10’ 1 1 2 2 2 4 3 11’ 2 2 1 1 2 4 4 12’ 3 3 0 0 2 5 4 14’ 2 2 2 2 3 4 5 15’ 3 3 1 1 3 6 5 16’ 4 4 0 0 3 6 6 18’ 3 3 2 2 4 7 6 19’ 4 4 1 1 4 6 7 20’ 5 5 0 0 4 8 7 22’ 4 4 2 2 5 8 8 23’ 5 5 1 1 5 9 8 24’ 6 6 0 0 5 9 26’ 5 5 2 2 6 10 9 27’ 6 6 1 1 6 10 10 28’ 7 7 0 0 6 11 10 30’ 6 6 2 2 7 10 11 31’ 7 7 1 1 7 12 11 32’ 8 8 0 0 7 12 12 34’ 7 7 2 2 8 13 12 35’ 8 8 1 1 8 12 13 36’ 9 9 0 0 8 14 13 38’ 8 8 2 2 9 14 14 39’ 9 9 1 1 9 13 14 40’ 10 10 0 0 9 8 1 2 No. of 3’ No. of Utility Lamps Compartments CONTINUOUS RUNS USING 5’ FIXTURE MODULES WITH 30” BEGINNING AND/OR END OR RUN FIXTURE MODULES CONTINUOUS RUNS USING 3’ FIXTURE MODULES Nominal Actual Run Length Length No. of Utility Compartments Nominal Actual No. of 5’ No. of 4’ No. of 30” Run Length Fixture Lamps Fixture Length Modules Modules No. of 3’ Fixture Modules No. of 2’ Lamps 6’ 2 2 1 9’ 3 3 2 12’ 4 4 3 15’ 5 5 4 18’ 6 6 5 21’ 7 7 6 24’ 8 8 7 27’ 9 9 8 30’ 10 10 9 33’ 11 11 10 36’ 12 12 11 39’ 13 13 12 42’ 14 14 13 45’ 15 15 14 48’ 16 16 15 51’ 17 17 16 54’ 18 18 17 57’ 19 19 18 55’ 11 11 57.5’ 11 11 60’ 20 20 19 60’ 12 12 0 No. of 2’ No. of Utility Lamps Compartments 7.5’ 1 1 1 1 10’ 2 2 0 0 1 1 12.5’ 2 2 1 1 2 15’ 3 3 0 0 2 17.5’ 3 3 1 1 3 20’ 4 4 0 0 3 22.5’ 4 4 1 1 4 25’ 5 5 0 0 4 27.5’ 5 5 1 1 5 30’ 6 6 0 0 5 32.5’ 6 6 1 1 6 35’ 7 7 0 0 6 37.5’ 7 7 1 1 7 40’ 8 8 0 0 7 42.5’ 8 8 1 1 8 45’ 9 9 0 0 8 47.5’ 9 9 1 1 9 50’ 10 10 0 0 9 52.5’ 10 10 1 1 10 0 0 10 1 1 11 0 11 Specifications and Dimensions subject to change without notice. Neo-Ray • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801 ADN081971 02/18/2010 11:16:02 AM