COOPER LIGHTING - METALUX ® DESCRIPTION The GR8 is a T8-dedicated lensed troffer designed to offer premium performance in a low profile housing. T8 dedication and optimized lamp to lens spacing provides the best in energy efficiency and optical control. The GR8’s shallow, low profile housing is compatible with even highly restrictive plenums. Luminaires are compatible with today’s popular ceiling systems. The GR8 offers great performance and great quality. The series is an excellent choice for commercial offices, schools, hospitals, retail merchandising and many other applications. Type Catalog # Project Date Comments Prepared by SPECIFICATION FEATURES Construction Electrical** Frame/Shielding Unitized low profile recessed housing is die formed of code gauge prime cold rolled steel with full length stiffeners and unibody endplate for added strength. Ballast cover is easily removed without tools. Die formed captive lampholder bracket fully encloses lampholder wiring for easy lampholder replacement. Ample KOs are provided for continuous row wiring. Built-in grid-lock feature for safety and convenience. Ballasts are CBM/ETL Class “P” and are positively secured by mounting bolts. Rotor-lock lampholders. UL/CUL listed. Suitable for damp locations. Heavy gauge flat steel door is die formed with reinforced mitered corners. Housing and door frame assemblies incorporate full width mechanical light traps. Light stabilized, acrylic prismatic lens. Finish Multistage, iron phosphate pretreatment ensures maximum bonding and rust inhibition. Lighting grade baked white enamel finish with premium reflectance for high efficiency. Hinging/Latching Positive spring loaded steel latches and safety lock T-hinges provide secure, high quality door fit and allow hinging and latching from either side. Controls Fifth Light ballast options are offered for both 0-10V continuous dimming and DALI applications. Combine with energy-saving products like occupancy sensors, daylighting controls, and lighting relay panels from Cooper Controls (www.coopercontrol.com) to maximize energy savings. 2GR8 228T8, 232 428T8, 432 2' X 4' TROFFER 2 OR 4 LAMP General Purpose T8 Commercial Troffer 3-1/4" [83mm] ENERGY DATA Input Watts: EB Ballast & STD Lamps 228T8 (49), 232 (61) 428T8 (98), 432 (122) 23-3/4" [603mm] Luminaire Efficacy Rating LER = FL-82 Catalog Number: 2GR8-232A LAMP CONFIGURATIONS MOUNTING DATA 2 LAMP Location of Standard Access Opening 3-1/4" [83mm] 1-1/2" [38mm] 1-1/2" [38mm] Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $2.93 10-3/4" [274mm] 23-3/4" [603mm] 23-3/4" [603mm] Catalog Number: 2GR8-432A LER = FL-76 4 LAMP 1" [26mm] 3-1/2" [89mm] 3-1/4" [83mm] 3-1/8" [80mm] 47-15/16" [1218mm] X=4-3/16" [107mm] Y=4-3/4" [121mm] X Y Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.16 X 23-3/4" [603mm] *Standard G (Grid) Type Fixtures can be field converted by adding trim kits. See Compatibility Section or Consult Factory. DOOR FRAMES 2GR8 F lat, White Steel ( White L atches) **Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements. ***When ordering Flange Kit for installation in drywall ceilings, see options and accessories compatibility section and ordering logic. CEILING COMPATIBILITY G Grid/Lay-in Standard G Concealed T COOPER LIGHTING G Slot Grid F Flange Trim With Supporting Swing Gates Ceiling Type Trim Type Exposed Grid Concealed T Slot Grid Flange G G G G*** LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS Safe and convenient means of disconnecting power. ADF012707 2GR8 PHOTOMETRICS 2GR8-232A Electronic Ballast (2) F32T8 lamps 3100 lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.4 x mounting height Efficiency 79.4% Test Report: 2GR8-232A.IES LER = FL-82 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $2.93 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 1851 1855 1830 1790 1731 1653 1554 1434 1297 1127 922 731 570 430 316 224 162 87 0 Across ⊥ 1851 1851 1845 1834 1813 1776 1720 1650 1551 1400 1182 924 675 476 343 262 198 114 0 45° 1851 1846 1830 1806 1768 1714 1643 1551 1424 1251 1060 851 619 413 261 179 142 89 0 Coefficients of Utilization rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 95 83 73 65 58 52 47 43 39 36 33 95 80 68 59 51 45 40 36 32 29 27 95 77 64 54 46 40 35 31 28 25 23 92 85 77 71 65 60 56 52 48 45 42 92 82 72 64 57 51 46 42 38 35 33 92 79 67 58 51 45 40 36 32 29 27 92 76 63 53 46 40 35 31 28 25 23 20% 50% 50 30 10 30% 50 30 10 10% 50 30 10 0% 0 88 78 69 61 55 49 45 41 37 34 32 84 75 66 59 53 48 43 40 36 33 31 81 72 64 57 51 46 42 39 35 33 30 79 68 57 49 42 37 32 29 26 23 21 88 76 65 56 49 44 39 35 32 29 26 88 74 62 52 45 39 35 31 28 25 23 84 73 63 55 48 43 38 34 31 28 26 Zonal Lumen Summary Luminance Data Zone 0-30 0-40 0-60 0-90 0-180 Angle in Deg 45 55 65 75 85 Lumens 1476 2440 4149 4924 4924 %Lamp 23.8 39.4 66.9 79.4 79.4 Candela Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 3662 3664 3613 3531 3413 3260 3067 2829 2538 2188 1816 1457 1138 859 626 447 314 172 14 Across ⊥ 3662 3657 3640 3610 3555 3461 3327 3155 2918 2591 2176 1729 1304 950 687 517 380 214 47 45° 3662 3647 3614 3560 3480 3365 3206 2998 2723 2383 2023 1630 1212 827 530 359 272 167 33 Coefficients of Utilization Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 95 87 80 73 67 62 57 53 49 46 43 2GR8-432A Electronic Ballast (4) F32T8 lamps 3100 lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.3 x mounting height Efficiency 77.1% Test Report: 2GR8-432A.IES LER = FL-76 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.16 Candela %Fixture 30.0 49.6 84.3 100.0 100.0 Average 0-Deg cd/sm 2556 2044 1632 1388 1601 84 71 60 52 45 39 34 31 27 25 22 Average 45-Deg cd/sm 2838 2380 1567 1109 1638 81 71 61 54 47 42 38 34 31 28 26 81 69 59 51 44 38 34 30 27 25 22 Average 90-Deg cd/sm 3176 2594 1807 1624 2098 rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 92 84 77 71 65 60 56 52 48 45 42 92 81 71 63 56 50 46 41 38 35 32 92 78 66 57 50 44 39 35 31 29 26 92 75 62 52 45 39 34 30 27 24 22 90 82 75 69 63 58 54 50 47 44 41 90 90 79 76 70 65 62 56 55 49 50 43 45 39 41 35 37 31 34 28 32 26 90 74 61 52 44 39 34 30 27 24 22 20% 50% 50 30 10 30% 50 30 10 50 86 76 67 60 53 48 43 40 36 33 31 82 73 65 57 52 46 42 39 35 33 30 79 70 62 56 50 45 41 37 34 32 30 86 74 63 55 48 42 38 34 31 28 26 86 71 60 51 44 38 34 30 27 24 22 82 71 61 53 47 42 37 33 30 28 25 Zonal Lumen Summary Luminance Data Zone 0-30 0-40 0-60 0-90 0-180 Angle in Deg 45 55 65 75 85 Lumens 2902 4769 8035 9566 9566 %Lamp 23.4 38.5 64.8 77.1 77.1 %Fixture 30.3 49.9 84.0 100.0 100.0 82 69 59 50 43 38 33 30 27 24 22 Average 0-Deg cd/sm 4963 4074 3260 2770 3165 Average 45-Deg cd/sm 5406 4558 3139 2225 3073 10% 30 10 79 69 60 52 46 41 37 33 30 27 25 79 67 57 49 43 37 33 30 27 24 22 0% 0 77 66 56 48 41 36 32 28 25 23 21 Average 90-Deg cd/sm 5877 4835 3606 3204 3938 Visit our web site at www.cooperlighting.com Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 4/13 ADF012707 2GR8 ORDERING INFORMATION SAMPLE NUMBER: 2GR8-232A-UNV-EB81-U Rating (4) Blank= Standard ATW-SW4= Chicago Rated Width 2=2' Width Trim Type G=Grid/Lay-in (Standard) Series R8=General Purpose T8 Commercial Troffer (1) Number of Lamps 2=2 Lamps 4=4 Lamps Voltage (2) 347V=347 Volt UNV=Universal Voltage 120-277 (3) (Not included) Wattage 28T8=28W T8 (48") 32=32W T8 (48") (5) Shielding A=#12 Acrylic Pattern A125=#12 Pattern Acrylic (.125" Thick) A19/156=#19 Pattern Acrylic (.156" Thick) PB1S=Silver Parabolic Louver (1/2" x 1/2" x 1/2") Options GL=Single Element Fuse GM=Double Element Fuse Flex=Flex Installed (Reference Flex ordering information) EL=Emergency Installed Lamps Installed Blank=No Lamps Installed L8835=T8 Lamp, 28W and 32W, 3500K L8841=T8 Lamp, 28W and 32W, 4100K L8835HL=T8 Lamp, 32W, 3500K, 3100 Lumens L8841HL=T8 Lamp, 32W, 4100K, 3100 Lumens (1) NOTES: An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per (2) fixture. Products also available in non-US voltages and frequencies for international markets. (3) (4) Not available when specifying emergencies, voltage must be specific. For NYC rated product, (5) (6) see separate specification sheets. Ballast Factor is 0.88 for 4 lamp 32W T8 fixtures. For a complete listing of Fifthlight Technology products and other solutions from Cooper Controls, visit (7) www.coopercontrol.com. 0-10V ballast do not include DALI feature. Please select DALI ballast for use (8) with Fifth Light system. Specification grade 0-10V dimming ballast are NEMA premium and CEE (9) listed. They are compatible with low mercury and energy saving lamps. Specification Grade 0-10V (10) ballast not offered in 3 or 4-lamp versions. Standard 0-10V ballast not available for 28W T8 lamps. (11) Voltage must be specified for Standard 0-10V 32W 3 and 4-lamp ballast. 4-lamp ballast versions must be 277V. For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. Ballast Type EB8 =T8 Electronic Start. Total Harmonic Distortion < 10% EB8 /PLUS= T8 Electronic Start. Total Harmonic Distortion < 10%. High Ballast Factor > 1.15. ER8 = T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10% High Performance T8 Ballasts HB8 =T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Standard Ballast Factor .86 – .88 HB8 L=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Low Ballast Factor .77 – .82 HB8 N=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Normal Ballast Factor 1.0 HB8 H=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. High Ballast Factor 1.15 – 1.20 HR8 T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Standard Ballast Factor .86 – .88 HR8 DIM=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Step Dimming. Ballast Factor .88 HR8 L=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Low Ballast Factor .71 – .79 HR8 H=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. High Ballast Factor 1.15 – 1.20 Options FR=Fire Label Packaging U=Unit Pack ACCESSORIES EQ-CLIP-U=T-BAR Safety Earthquake Clips (1) FCTKA-24W-U=Field Installed Flange Kit FCTK A – 24 R W – U Trim Kit Field Convertible 22=2' x 2' 24=2' x 4' N=Natural W=White Blank=Single R=In Row E=End Row U=Unit Pack Aluminum 0-10V Dimming Ballasts (7) 5LTV8 =T8 0-10V Program Rapid Start. Total Harmonic Distortion < 10%. Ballast Factor 0.87 (10), (11) 5LTVS8 =T8 0-10V Spec Grade Program Rapid Start. Total Harmonic Distortion < 10%. Ballast Factor 0.87 (8), (9) Fifth Light DALI Ballasts (6) 5LT8 =T8 DALI Program Rapid Start. Total Harmonic Distortion < 10%. Ballast Factor 1.0 Number of Ballasts 1=1 Ballast 2=2 Ballasts 3=3 Ballasts SHIPPING INFORMATION Catalog No. Wt. 2GR8-228T8A 2GR8-232A 2GR8-428T8A 2GR8-432A 20 lbs. 20 lbs. 20 lbs. 20 lbs. Visit our web site at www.cooperlighting.com Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 4/13 ADF012707