COOPER LIGHTING - METALUX

advertisement
COOPER LIGHTING - METALUX
®
DESCRIPTION
The GR8IC is a T8-dedicated lensed troffer designed to offer premium
performance in a low profile housing. T8 dedication and optimized
lamp to lens spacing provides the best in energy efficiency and optical
control. The GR8IC is designed for installations when the housing
will be in direct contact with installation.
Type
Catalog #
Project
Date
Comments
The GR8IC offers great performance and great quality. The series is
an excellent choice for commercial offices, schools, hospitals, retail
merchandising and many other applications.
Prepared by
SPECIFICATION FEATURES
Construction
Electrical**
Frame/Shielding
Unitized low profile recessed
housing is die formed of
code gauge prime cold
rolled steel with full length
stiffeners and unibody
endplate for added strength.
Ballast cover is easily
removed without tools. Die
formed captive lampholder
bracket fully encloses
lampholder wiring for easy
lampholder replacement.
Ample KOs are provided for
continuous row wiring. Builtin grid-lock feature for safety
and convenience.
Ballasts are CBM/ETL Class “P” and are
positively secured by mounting bolts.
Rotor-lock lampholders. UL/cUL Listed
Type IC Recessed Luminaire for direct
contact with insulation. Suitable for
damp locations.
Heavy gauge flat steel door is die
formed with reinforced mitered
corners. Housing and door frame
assemblies incorporate full width
mechanical light traps. Light
stabilized, acrylic prismatic lens.
Finish
Controls
Multistage, iron phosphate
pretreatment ensures maximum
bonding and rust inhibition. Lighting
grade baked white enamel finish with
premium reflectance for high efficiency.
Fifth Light ballast options are
offered for both 0-10V
continuous dimming and DALI
applications. Combine with
energy-saving products like
occupancy sensors, daylighting
controls, and lighting relay
panels from Cooper Controls
(www.coopercontrol.com) to
maximize energy savings.
Hinging/Latching
Positive spring loaded steel latches and
safety lock T-hinges provide secure,
high quality door fit and allow hinging
and latching from either side.
2GR8IC
2U6T8
2U1-5/8
217, 317, 417
2' X 2' TROFFER
2, 3 OR 4 LAMPS
General Purpose
T8 Commercial Troffer
3-1/4"
[83mm]
FOR USE IN INSULATED
CEILINGS
23-3/4" [603mm]
MOUNTING DATA
X=5-3/16"
[132mm]
6"
6"
X
[152mm]
[152mm]
23-3/4" [603mm]
2U1-5/8
2-7/8" [74mm]
23-15/16" [610mm]
X=4-3/16"
[107mm]
Y=4-3/4"
[121mm]
X
Y
X
23-3/4" [603mm]
Luminaire Efficacy Rating
LER = FL-73
Catalog Number: 2GR8IC-2U6T8A
217
3-1/4" [83mm]
X=1-5/8"
[41mm]
EB Ballast & STD Lamps
217 (36) , 2U1-5/8 (61), 2U6T8 (61)
317 (52), 417 (63)
3-1/4" [83mm]
3-1/4" [83mm]
23-3/4"
[603mm]
Input Watts:
417
2U6T8
1-1/2"
[38mm]
ENERGY DATA
LAMP CONFIGURATIONS
3-1/4" [83mm]
10-3/8"
X
[264mm]
23-3/4" [603mm]
X
10-3/4"
[274mm]
23-3/4" [603mm]
Yearly Cost of 1000 lumens, 3000
hrs at .08 KWH = $3.29
317
3-1/4" [83mm]
DOOR FRAMES
X=5-3/8"
[137mm]
2GR8
F lat, White
Steel ( White
L atches)
X
*Standard G (Grid) Type Fixtures can be
field converted by adding trim kits. See
Compatibility Section or Consult Factory.
X
23-3/4" [603mm]
**Reference the lamp/ballast data in the
Technical Section for specific lamp/ballast
requirements.
***Order FCS-22W-U Flange Kit for
installation in drywall ceiling. See options
and accessories compatibility section.
CEILING COMPATIBILITY
G
Grid/Lay-in
Standard
G
Concealed T
COOPER LIGHTING
G
Slot Grid
F
Flange Trim
With Supporting
Swing Gates
Ceiling
Type
Trim
Type
Exposed Grid
Concealed T
Slot Grid
Flange
G
G
G
G***
LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL,
STATE OR FEDERAL LAWS
Safe and convenient means of
disconnecting power.
ADF100878
2GR8IC
PHOTOMETRICS
2GR8IC-2U6T8A
Electronic Ballast
(2) 31W U6T8 lamps
2850 lumens
Spacing criterion:
(II) 1.2 x mounting
height, (⊥) 1.3 x
mounting height
Efficiency 77.1%
Test Report:
2GR8IC-2U6T8A.IES
LER = FL-73
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $3.29
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Along II
1775
1771
1742
1696
1629
1547
1443
1317
1171
996
805
638
491
361
271
210
153
82
0
Across ⊥
1775
1773
1768
1749
1719
1670
1591
1486
1363
1195
993
780
574
406
307
245
179
90
0
45°
1775
1769
1749
1717
1672
1607
1522
1406
1264
1075
877
688
495
330
224
175
146
86
0
Coefficients of Utilization
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
92
81
72
63
57
51
46
42
38
35
33
92
78
67
58
50
44
40
36
32
29
27
92
75
63
53
45
40
35
31
28
25
23
90
82
75
69
64
59
55
51
47
44
42
90
79
70
62
56
50
45
41
38
35
32
90
77
66
57
50
44
39
35
32
29
27
90
74
62
52
45
39
35
31
28
25
23
20%
50%
50 30 10
30%
50 30 10
10%
50 30 10
0%
0
86
76
67
60
54
49
44
40
37
34
32
82
73
65
58
52
47
43
39
36
33
31
79
70
63
56
50
46
42
38
35
32
30
77
66
56
48
42
37
32
29
26
23
21
86
74
64
55
49
43
39
35
31
29
26
86
72
60
51
45
39
34
31
28
25
23
82
71
62
54
48
42
38
34
31
28
26
Zonal Lumen Summary
Luminance Data
Zone
0-30
0-40
0-60
0-90
0-180
Angle
in Deg
45
55
65
75
85
Lumens
1394
2269
3729
4398
4398
%Lamp
24.5
39.8
65.4
77.1
77.1
Candela
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Along II
795
794
782
763
734
699
652
597
528
449
363
287
220
165
123
96
70
38
0
Across ⊥
795
796
794
790
781
765
734
695
646
574
478
371
273
189
143
112
82
40
0
45°
795
792
785
774
756
731
697
648
586
503
413
325
235
155
104
81
68
39
0
Coefficients of Utilization
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
92
84
77
71
65
60
56
52
49
45
43
2GR8IC-217A
Electronic Ballast
(2) F32T8 lamps
1350 lumens
Spacing criterion:
(II) 1.2 x mounting
height, (⊥) 1.4 x
mounting height
Efficiency 75.1%
Test Report:
2GR8IC-217A.IES
LER = FL-60
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $4.00
Candela
%Fixture
31.7
51.6
84.8
100.0
100.0
Average
0-Deg
cd/sm
3789
2992
2298
2183
2531
82
69
59
51
44
39
34
30
27
25
23
Average
45-Deg
cd/sm
4090
3227
2100
1819
2654
79
69
60
53
47
41
37
34
31
28
26
79
67
58
50
43
38
34
30
27
25
22
Average
90-Deg
cd/sm
4546
3658
2584
2546
2778
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
89
82
75
69
64
59
54
50
47
44
41
89
79
70
62
55
49
45
41
37
34
32
89
76
65
56
49
43
38
34
31
28
26
89
73
61
51
44
38
34
30
27
24
22
87
80
73
67
62
57
53
49
46
43
40
87
77
68
61
54
49
44
40
37
34
31
87
74
64
55
48
43
38
34
31
28
26
87
72
60
51
44
38
34
30
27
24
22
20%
50%
50 30 10
30%
50 30 10
50
83
74
66
58
52
47
43
39
36
33
30
80
71
63
56
51
46
41
38
35
32
30
77
68
61
54
49
44
40
37
34
31
29
83
72
62
54
47
42
37
34
30
28
25
83
70
59
50
43
38
33
30
27
24
22
80
69
60
52
46
41
37
33
30
27
25
Zonal Lumen Summary
Luminance Data
Zone
0-30
0-40
0-60
0-90
0-180
Angle
in Deg
45
55
65
75
85
Lumens
631
1035
1718
2027
2027
%Lamp
23.4
38.3
63.6
75.1
75.1
%Fixture
31.1
51.0
84.7
100.0
100.0
80
68
57
49
43
37
33
29
26
24
22
Average
0-Deg
cd/sm
2231
1758
1372
1303
1532
Average
45-Deg
cd/sm
2499
1991
1289
1100
1572
10%
30 10
77
67
58
51
45
40
36
33
30
27
25
77
66
56
48
42
37
33
29
26
24
22
0%
0
75
64
54
47
40
35
31
28
25
22
20
Average
90-Deg
cd/sm
2852
2273
1571
1520
1613
Visit our web site at www.cooperlighting.com
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801
4/13
ADF100878
2GR8IC
ORDERING INFORMATION
SAMPLE NUMBER: 2GR8IC-2U6T8A-UNV-EB81-U
Rating
Blank=
Standard
ATW-SW4=
Chicago
Rated
Width
2=2' Width
Trim Type
G=Grid/Lay-in
(Standard)
Series
R8=General
Purpose T8
Commercial
Troffer (1)
Number of
Lamps (4), (5)
2=2 Lamps
3=3 Lamps
4=4 Lamps
(Not included)
Wattage
17=17W T8 (24")
U6T8=32W (24") (5), (6)
U1-5/8=31W T8 (24") (5), (7)
Shielding
A=#12 Acrylic Pattern
A125=#12 Pattern Acrylic
(.125" Thick)
A19/156=#19 Pattern
Acrylic (.156" Thick)
PB1S=Silver Parabolic
Louver (1/2" x 1/2" x 1/2")
Voltage (2)
120V=120 Volt
277V=277 Volt
347V=347 Volt
UNV=Universal Voltage
120-277 (3)
Options
GL=Single Element Fuse
GM=Double Element Fuse
Lamps=Lamps Installed
Flex=Flex Installed
EL=Emergency Installed
Type
IC=IC Rated
(1)
(2)
NOTES: An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per fixture. Products
(3)
also available in non-US voltages and frequencies for international markets. Not available when specifying
(4)
(5)
emergencies, voltage must be specific. Standard off center ballast on 3 lamp fixtures. 2 lamps maximum
(6)
(7)
for U6T8 and U1-5/8. Ballast Factor is 0.88 for 4 lamp 32W T8 fixtures. Fifthlight ballast option not available.
(8)
For a complete listing of Fifthlight Technology products and other solutions from Cooper Controls, visit
(9)
www.coopercontrol.com. 0-10V ballast do not include DALI feature. Please select DALI ballast for use with Fifth
(10)
Light system.
Specification grade 0-10V dimming ballast are NEMA premium and CEE listed. They are compatible
(11)
with low mercury and energy saving lamps.
Specification Grade 0-10V ballast not offered in 3 or 4-lamp versions.
(12)
Standard 0-10V ballast not offered in 3 or 4-lamp versions
For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject
to change without notice. Consult your Cooper Lighting Representative for availability and ordering information.
Packaging
U=Unit Pack
Ballast Type
EB8 =T8 Electronic Start.
Total Harmonic Distortion < 10%
EB8 /PLUS= T8 Electronic Start.
Total Harmonic Distortion < 10%.
High Ballast Factor > 1.15.
ER8 = T8 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%
High Performance T8 Ballasts
HB8 =T8 Electronic Instant Start.
Total Harmonic Distortion < 10%.
Standard Ballast Factor .86 – .88
HB8 L=T8 Electronic Instant Start.
Total Harmonic Distortion < 10%.
Low Ballast Factor .77 – .82
HB8 N=T8 Electronic Instant Start.
Total Harmonic Distortion < 10%.
Normal Ballast Factor 1.0
HB8 H=T8 Electronic Instant Start.
Total Harmonic Distortion < 10%.
High Ballast Factor 1.15 – 1.20
HR8 T8 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%.
Standard Ballast Factor .86 – .88
HR8 DIM=T8 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%.
Step Dimming. Ballast Factor .88
HR8 L=T8 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%.
Low Ballast Factor .71 – .79
HR8 H=T8 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%.
High Ballast Factor 1.15 – 1.20
0-10V Dimming Ballasts (9)
5LTV8 =T8 0-10V Program Rapid Start.
Total Harmonic Distortion < 10%.
Ballast Factor 0.87 (12)
5LTVS8 =T8 0-10V Spec Grade Program
Rapid Start. Total Harmonic
Distortion < 10%. Ballast Factor 0.87 (10), (11)
Fifth Light DALI Ballasts (8)
5LT8 =T8 DALI Program Rapid Start.
Total Harmonic Distortion < 10%.
Ballast Factor 1.0
Number of Ballasts
1=1 Ballast
2=2 Ballasts
3=3 Ballasts
ACCESSORIES
EQ-CLIP-U=T-BAR Safety Earthquake Clips (1)
FCTKA-22W-U=Field Installed Flange Kit
FCTK
A – 24
R W – U
Trim Kit
Field
Convertible
22=2' x 2'
24=2' x 4'
N=Natural
W=White
Blank=Single
R=In Row
E=End Row
U=Unit Pack
Aluminum
SHIPPING INFORMATION
Catalog No.
Wt.
2GR8IC-217A
2GR8IC-417A
2GR8IC-2U6T8A
2GR8IC-2U1-5/8A
12 lbs.
12 lbs.
12 lbs.
12 lbs.
Visit our web site at www.cooperlighting.com
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801
4/13
ADF100878