COOPER LIGHTING - METALUX ® DESCRIPTION The GR5 is a T5-dedicated lensed troffer designed to offer premium performance in a low profile housing. The GR5’s shallow, low profile housing is compatible with even highly restrictive plenums. Luminaires are compatible with today’s popular ceiling systems. Catalog # The GR5 offers great performance and great quality. The series is an excellent choice for commercial offices, schools, hospitals, retail merchandising and many other applications. Comments Type Project Date Prepared by SPECIFICATION FEATURES Construction Electrical** Frame/Shielding Unitized low profile recessed housing is die formed of code gauge prime cold rolled steel with full length stiffeners and mechanical endplate attachment for added strength. Off center, ballast cover is easily removed without tools. Die formed captive lampholder bracket fully encloses lampholder wiring for easy lampholder replacement. Ample KOs are provided for continuous row wiring. Built-in grid-lock feature for safety and convenience. Ballasts are CBM/ETL Class “P” and are positively secured by mounting bolts. Rotor-lock T5 lampholders. UL/CUL listed. Suitable for damp locations. Heavy gauge flat steel door is die formed with reinforced mitered corners. Housing and door frame assemblies incorporate full length and width mechanical light traps. Light stabilized, acrylic prismatic lens. Finish Multistage, iron phosphate pretreatment ensures maximum bonding and rust inhibition. Lighting grade baked white enamel finish with premium reflectance for high efficiency. Hinging/Latching Positive spring loaded steel latches and safety lock T-hinges provide secure, high quality door fit and allow hinging and latching from either side. Controls Fifth Light ballast options are offered for both 0-10V continuous dimming and DALI applications. Combine with energy-saving products like occupancy sensors, daylighting controls, and lighting relay panels from Cooper Controls (www.coopercontrol.com) to maximize energy savings. 2GR5 328T5 354T5 2' X 4' TROFFER 3 LAMP T5 General Purpose T5 Commercial Troffer 3-1/4" [83mm] 23-3/4" [603mm] ENERGY DATA MOUNTING DATA LAMP CONFIGURATIONS Input Watts: EB Ballast & STD Lamps 328T5 (99) 354T5 (182) 3-1/4" [83mm] Location of Standard Access Opening X=5-3/8" [137mm] 1-1/2" [38mm] 23-3/4" [603mm] X X 23-3/4" [603mm] Luminaire Efficacy Rating LER = FL-73 Catalog Number: 2GR5-328T5A 2-11/16" [69mm] 1" [26mm] 1-1/2" [38mm] 3-1/2" [89mm] Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.29 3-1/8" [80mm] 47-15/16" [1218mm] *Standard G (Grid) Type Fixtures can be field converted by adding trim kits. See Compatibility Section or Consult Factory. DOOR FRAMES 2GR5 F lat, White Steel ( White L atches) **Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements. ***When ordering Flange Kit for installation in drywall ceilings, see options and accessories compatibility section and ordering logic. CEILING COMPATIBILITY G Grid/Lay-in Standard G Concealed T COOPER LIGHTING G Slot Grid F Flange Trim With Supporting Swing Gates Ceiling Type Trim Type Exposed Grid Concealed T Slot Grid Flange G G G G*** LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS Safe and convenient means of disconnecting power. ADF110893 2GR5 PHOTOMETRICS 2GR5-328T5A Electronic Ballast (3) F28W/T5/835 lamps 2900 lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.3 x mounting height Efficiency 78.7% Test Report: 2GR5-328T5A.IES LER = FL-73 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.29 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 2561 2566 2533 2480 2402 2297 2164 1996 1798 1549 1289 1028 807 612 451 322 230 128 0 Across ⊥ 2561 2561 2550 2527 2486 2421 2329 2211 2067 1872 1606 1319 998 731 521 389 285 167 0 45° 2561 2552 2532 2498 2440 2362 2251 2111 1926 1699 1446 1190 908 621 400 263 200 126 0 Coefficients of Utilization rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 94 82 72 64 57 51 46 42 38 35 32 94 79 67 58 50 44 39 35 32 29 26 94 76 63 53 45 39 34 30 27 25 22 91 84 77 70 64 59 55 51 47 44 42 91 81 71 63 56 50 45 41 38 35 32 91 78 66 57 50 44 39 35 31 29 26 91 75 62 52 45 39 34 30 27 24 22 20% 50% 50 30 10 30% 50 30 10 10% 50 30 10 0% 0 87 77 68 60 54 49 44 40 37 34 31 84 74 66 58 52 47 43 39 36 33 31 80 71 63 56 51 46 41 38 35 32 30 79 67 56 48 41 36 32 28 25 23 21 87 75 64 56 49 43 38 34 31 28 26 87 73 61 52 44 39 34 30 27 24 22 84 72 62 54 48 42 38 34 31 28 26 Zonal Lumen Summary Luminance Data Zone 0-30 0-40 0-60 0-90 0-180 Angle in Deg 45 55 65 75 85 Lumens 2036 3351 5708 6843 6843 %Lamp 23.4 38.5 65.6 78.7 78.7 Candela Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 3940 3949 3902 3820 3696 3540 3331 3092 2769 2399 1983 1600 1240 944 705 503 360 202 0 Across ⊥ 3940 3937 3922 3888 3820 3718 3576 3393 3181 2873 2471 2027 1544 1117 806 599 443 254 0 45° 3940 3929 3898 3839 3749 3628 3459 3245 2960 2616 2227 1835 1413 961 624 411 309 194 0 Coefficients of Utilization Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 94 86 79 72 66 61 56 52 49 46 43 2GR5-354T5A Electronic Ballast (3) F54W/T5/835 lamps 4400 lumens Spacing criterion: (II) 1.3 x mounting height, (⊥) 1.3 x mounting height Efficiency 79.8% Test Report: 2GR5-354T5A.IES LER = FL-64 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.75 Candela %Fixture 29.7 49.0 83.4 100.0 100.0 Average 0-Deg cd/sm 3514 2875 2323 1996 2356 84 70 59 51 44 38 34 30 27 24 22 Average 45-Deg cd/sm 3854 3328 2357 1630 2319 80 70 61 53 46 41 37 33 30 28 25 80 68 58 50 43 38 33 30 27 24 22 Average 90-Deg cd/sm 4246 3689 2774 2411 3073 rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 95 87 80 73 67 62 57 53 49 46 43 95 84 73 65 58 52 47 43 39 36 33 95 80 68 59 51 45 40 36 32 29 27 95 77 64 54 46 40 35 31 28 25 23 93 85 78 71 65 60 56 52 48 45 42 93 82 72 64 57 51 46 42 38 35 33 93 79 67 58 50 44 39 35 32 29 27 93 76 63 53 46 40 35 31 28 25 23 20% 50% 50 30 10 30% 50 30 10 50 89 78 69 61 55 49 45 41 37 34 32 85 75 67 59 53 48 43 40 36 33 31 81 72 64 57 51 46 42 38 35 33 30 89 76 65 56 49 44 39 35 31 29 26 89 74 62 52 45 39 34 31 27 25 22 85 73 63 55 48 43 38 34 31 28 26 Zonal Lumen Summary Luminance Data Zone 0-30 0-40 0-60 0-90 0-180 Angle in Deg 45 55 65 75 85 Lumens 3130 5152 8785 10540 10540 %Lamp 23.7 39.0 66.6 79.8 79.8 %Fixture 29.7 48.9 83.4 100.0 100.0 Average 0-Deg cd/sm 5442 4474 3583 3117 3718 85 71 60 51 44 39 34 30 27 25 22 Average 45-Deg cd/sm 5934 5131 3647 2547 3570 10% 30 10 81 71 61 54 47 42 37 34 31 28 26 0% 0 81 69 59 51 44 38 34 30 27 24 22 80 68 57 49 42 37 32 29 26 23 21 Average 90-Deg cd/sm 6517 5668 4239 3712 4675 Visit our web site at www.cooperlighting.com Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 4/13 ADF110893 2GR5 ORDERING INFORMATION SAMPLE NUMBER: 2GR5-328T5A-UNV-EBT1-U Rating (4) Blank= Standard ATW-SW4= Chicago Rated Width 2=2' Width Trim Type G=Grid/Lay-in (Standard) Series R5=General Purpose T5 Commercial Troffer (1) (1) Number of Lamps 3=3 Lamps (Not included) Wattage 28T5=28W T5 (48") 54T5=54W T5HO (48") Shielding A=#12 Acrylic Pattern A125=#12 Pattern Acrylic (.125" Thick) A19/156=#19 Pattern Acrylic (.156" Thick) PB1S=Silver Parabolic Louver (1/2" x 1/2" x 1/2") Options FR=Fire Label Voltage (2) 347V=347 Volt UNV=Universal Voltage 120-277 (3) Ballast Type EBT =T5 or T5HO Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Standard Ballast Factor=1.0 Options GL=Single Element Fuse GM=Double Element Fuse Lamps=Lamps Installed Flex=Flex Installed EL=Emergency Installed EBT N=T5 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Normal Ballast Factor=.90 (5) EBT H=T5 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. High Ballast Factor=1.15 (7) EBT NDIM=T5 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Step Dimming, Normal Ballast Factor=.95-1.0 (6) EBT HDIM=T5 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Step Dimming, High Ballast Factor=1.15 Packaging U=Unit Pack Ballast/FactorType (2) NOTES: An EQ Grid Clip is recommended for all 9/16" ceiling systems. Products also available in (3) non-US voltages and frequencies for international markets. Not available when specifying (4) emergencies, voltage must be specific. For NYC rated product, see separate specification sheets. (5) (6) .90 ballast factor available for 2 or 3 14W T5 or 28W T5 lamps only. 1-Lamp step dimming ballast (7) in a Normal Ballast factor not available. 2-Lamp ballast will not operate 1-Lamp. 1-Lamp ballast in (8) a High Ballast factor not available. For a complete listing of Fifthlight Technology products and other solutions from Cooper Controls, visit www.coopercontrol.com Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. Fifth Light DALI Ballasts (8) 5LT5 =T5 DALI Program Rapid Start. Total Harmonic Distortion < 10%. Ballast Factor 1.0 5LT5H =T5HO DALI Program Rapid Start. Total Harmonic Distortion < 10%. Ballast Factor 1.0 Number of Ballasts 1=1 Ballast 2=2 Ballasts 3=3 Ballasts ACCESSORIES EQ-CLIP-U=T-BAR Safety Earthquake Clips (1) FCTKA-24W-U=Field Installed Flange Kit FCTK A – 24 R W – U Trim Kit Field Convertible 22=2' x 2' 24=2' x 4' N=Natural W=White Blank=Single R=In Row E=End Row U=Unit Pack Aluminum SHIPPING INFORMATION Catalog No. Wt. 2GR5-328T5A 2GR5-354T5A 22 lbs. 25 lbs. Visit our web site at www.cooperlighting.com Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 4/13 ADF110893