METALUX ® DESCRIPTION GC8 is a premium grade specification lensed troffer series. This innovative, high quality luminaire is dedicated to the latest T8 lamp and micro electronic ballast technology for optimal performance and energy efficiency. The GC8 is compatible with all of today’s popular ceiling systems and is available with a number of options and accessories for application versatility. Catalog # The GC8 series features efficiency, quality and performance. The series is an excellent choice for commercial office spaces, schools, hospitals or retail merchandising areas. Prepared by Type Project Date Comments SPECIFICATION FEATURES Construction Electrical Frame/Shielding Rigid housing is die formed of code gauge prime cold rolled steel and features full length die-formed stiffeners and unibody endplate for added strength. Side flanges are hemmed. Innovative design provides superior lens brightness uniformity and visual comfort. Micro ballast cover*** reduces ballast shadow for superior lens brightness uniformity and is easily removed without tools. Die formed captive lampholder brackets fully enclose lampholder wiring permitting easy lampholder replacement. Unibody endplates are securely attached with interlocking tabs and screws. Four auxiliary fixture end suspension points provided. KOs for continuous row wiring. Endplates have integral Grid-lock feature for safety and convenience. Ballasts are CBM/ETL Class “P” and are positively secured by mounting bolts. Rotor lock lampholders. UL/CUL listed. Suitable for damp locations.** Die formed, heavy gauge, flat steel door with reinforced mitered corners and baked white enamel finish. Flat and regressed aluminum doors also available. Positive light seals. Light stabilized, acrylic prismatic lens. Standard #12 pattern. Numerous additional shielding options available. Finish Multistage, iron phosphate pretreatment ensures maximum bonding and rust inhibition. Housing and ballast cover finished with new 90% reflective white enamel for superior performance. “PAF” Painted After Fabrication option also available. Hinging/Latching Positive Cam latch with baked white enamel finish. Safety-lock Thinges allow hinging and latching either side. 2GC8 228T8 232 428T8 432 Controls Fifth Light ballast options are offered for both 0-10V continuous dimming and DALI applications. Combine with energy-saving products like occupancy sensors, daylighting controls, and lighting relay panels from Cooper Controls (www.coopercontrol.com) to maximize energy savings. 2' X 4' TROFFER 2 OR 4 LAMP Specification T8 Troffer 3-1/4" [83mm] ENERGY DATA 23-3/4" [603mm] Input Watts: HB Ballast & STD Lamps 228T8 (48), 232 (53) 428T8 (96), 432 (107) DOOR FRAMES MOUNTING DATA GC8 Flat, White Steel Location of Standard Access Opening 1-1/2" [38mm] GC8FA Flat, Extruded White Aluminum GC8RA Deep, Regressed, Extruded Natural Aluminum 1-1/2" [38mm] 23-3/4" [603mm] Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.00 1" [26mm] 3-1/2" [89mm] LAMP CONFIGURATIONS 3-1/8" [79mm] 47-15/16" [1218mm] *Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements. 3-1/4" [83mm] 10-3/4" [274mm] 23-3/4" [603mm] **Consult Pre Sales Technical Support. ***Full sized ballast cover for biaxial lamps and emergency option may apply. 3-1/4" [83mm] X=4-3/16" [107mm] Y=5-3/8" [137mm] CEILING COMPATIBILITY G Grid/Lay-in Standard G Concealed T G Slot Grid Luminaire Efficacy Rating LER = FL-80 Catalog Number: 2GC8-232A F Flange Trim With Supporting Swing Gates X Y ****When ordering Flange Kit for installation in drywall ceilings, see options and accessories compatibility section and ordering logic. X 23-3/4" [603mm] Ceiling Type Trim Type Exposed Grid Concealed T Slot Grid Flange G G G F LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS Safe and convenient means of disconnecting power. (Verify compatibility/ consult factory.) COOPER LIGHTING ADF091407 2GC8 T8 PHOTOMETRICS 2GC8-232A Electronic Ballast (2) F032/35K T8 lamps 3100 lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.4 x mounting height Efficiency 84.7% Test Report: 2GC8-232A.IES LER = FL-80 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.00 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 1963 1966 1940 1895 1834 1753 1646 1525 1373 1186 986 795 623 471 347 247 175 93 7 Across ⊥ 1963 1962 1956 1944 1924 1883 1822 1745 1635 1463 1235 974 734 528 383 288 212 118 23 45° 1963 1957 1941 1914 1876 1820 1741 1640 1502 1323 1131 917 677 460 295 198 151 92 16 Coefficients of Utilization rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 101 89 78 69 62 55 50 45 41 38 35 101 101 85 82 73 68 63 57 54 49 48 42 42 37 38 33 34 29 31 27 28 24 99 90 83 76 69 64 59 55 51 48 45 99 87 77 68 60 54 49 45 41 37 35 99 84 71 62 54 47 42 38 34 31 28 99 81 67 57 49 42 37 33 29 26 24 20% 50% 50 30 10 30% 50 30 10 50 94 83 74 65 58 52 48 43 40 37 34 90 80 71 63 56 51 46 42 39 36 33 86 77 68 61 55 49 45 41 38 35 32 94 81 69 60 53 46 41 37 34 31 28 94 78 66 56 48 42 37 33 29 26 24 90 78 67 59 51 45 41 37 33 30 28 Zonal Lumen Summary Luminance Data Zone 0-30 0-40 0-60 0-90 0-180 Angle in Deg 45 55 65 75 85 Lumens 1565 2585 4403 5254 5254 %Lamp 25.2 41.7 71.0 84.7 84.7 Candela Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 3892 3891 3838 3750 3626 3460 3256 3001 2700 2329 1924 1543 1203 907 669 472 335 182 15 Across ⊥ 3892 3885 3865 3826 3758 3654 3510 3321 3071 2728 2295 1825 1386 1004 729 547 405 228 48 45° 3892 3875 3839 3777 3687 3561 3388 3164 2878 2520 2136 1724 1288 877 563 378 287 175 32 Coefficients of Utilization Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 101 93 85 78 71 66 61 56 53 49 46 2GC8-432A Electronic Ballast (4) F032/35K T8 lamps 3100 lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.3 x mounting height Efficiency 81.6% Test Report: 2GC8-432A.IES LER = FL-85 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $2.82 Candela %Fixture 29.8 49.2 83.8 100.0 100.0 Average 0-Deg cd/sm 2690 2223 1788 1531 1712 90 76 64 55 47 41 36 32 29 26 24 10% 30 10 Average 45-Deg cd/sm 3001 2564 1746 1227 1693 86 75 65 57 50 45 40 36 33 30 27 86 74 63 54 47 41 36 32 29 26 24 0% 0 85 72 61 52 45 39 34 30 27 25 22 Average 90-Deg cd/sm 3319 2724 2004 1785 2172 rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 97 89 82 75 69 64 59 55 51 48 45 97 86 75 67 59 53 48 44 40 37 34 97 82 70 60 53 46 41 37 33 30 28 97 79 66 55 47 41 36 32 29 26 23 95 87 80 73 67 62 57 53 50 46 44 95 84 74 65 58 53 47 43 40 36 34 95 81 69 60 52 46 41 37 33 30 28 20% 95 78 65 55 47 41 36 32 29 26 23 50% 50 30 10 30% 50 30 10 50 91 80 71 63 56 51 46 42 38 35 33 87 77 68 61 55 49 45 41 37 35 32 83 74 66 59 53 48 43 40 36 34 31 91 78 67 58 51 45 40 36 33 30 27 91 76 63 54 46 40 36 32 28 26 23 87 75 65 57 50 44 39 35 32 29 27 Zonal Lumen Summary Luminance Data Zone 0-30 0-40 0-60 0-90 0-180 Angle in Deg 45 55 65 75 85 Lumens 3075 5048 8502 10124 10124 %Lamp 24.8 40.7 68.6 81.6 81.6 %Fixture 30.4 49.9 84.0 100.0 100.0 Average 0-Deg cd/sm 5283 4315 3442 2925 3349 87 73 62 53 46 40 35 31 28 26 23 10% 30 10 Average 45-Deg cd/sm 5716 4821 3329 2343 3221 83 73 63 55 49 43 39 35 32 29 27 83 71 61 52 45 40 35 31 28 25 23 0% 0 82 69 59 50 43 38 33 30 27 24 22 Average 90-Deg cd/sm 6188 5104 3811 3390 4196 Visit our web site at www.cooperlighting.com Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 2/24/16 ADF091407 2GC8 T8 ORDERING INFORMATION SAMPLE NUMBER: 2GC8-232A-UNV-HB81-U Rating (5) Blank= Standard ATW-SW4= Chicago Rated Width 2=2' Width Trim Type G=Grid/Lay-in (Standard) (1) G=Concealed T G=Slot Grid F=Flange Trim Series C8=Specification T8 Troffer Door Frame Standard=Flat White Steel Door (Leave Blank) FA=Flush White Extruded Aluminum c/w Spring Latch RA=Regressed White Extruded Aluminum FAN=Flush Natural Anodized Extruded Aluminum RAN=Regressed Natural Anodized Extruded Aluminum FAB=Flush Black Extruded Aluminum RAB=Regressed Black Extruded Aluminum (1) Number of Lamps (2) 2 or 4 Lamps (Not included) Wattage (Length) 28T8=28W T8 (48") 32=32W T8 (48")(8) Shielding A=#12 Acrylic Pattern A125=#12 Acrylic Pattern (.125" Thickness) A19/156=#19 Acrylic Pattern (.156" Thickness) PB1S=1/2" x 1/2" x 1/2" Silver Parabolic Louver (Styrene) Option – Aluminum Flange Trim (6) Blank=SW (Single White) Type Color ‘S’ Single ‘N’ Natural ‘R’ In Row ‘W’ White ‘E’ End of Row Voltage (3) 347V=347 Volt UNV=Universal Voltage 120-277 (4) Options GL=Single Element Fuse GM=Double Element Fuse Lamps=Lamps Installed Flex=Flex Installed EL=Emergency Installed (2) NOTES: An EQ Grid Clip is recommended for all 9/16" ceiling systems. Standard off-center ballast on 3-lamp (3) (4) fixtures. Products also available in non-US voltages and frequencies for international markets. Not available (5) when specifying emergencies, voltage must be specific. For NYC rated product, see separate specification (6) (7) sheets. Specify row configuration, type in catalog number when ordering complete fixture. For a complete listing of Fifthlight Technology products and other solutions from Cooper Controls, visit www.coopercontrol.com. (8) (9) Ballast Factor is 0.88 for 4 lamp 32W T8 fixtures. 0-10V ballast do not include DALI feature. Please select DALI ballast (10) for use with Fifth Light system. Specification grade 0-10V dimming ballast are NEMA premium and CEE listed. They (11) are compatible with low mercury and energy saving lamps. Specification Grade 0-10V ballast not offered in 3 or 4(12) (13) lamp versions. Standard 0-10V ballast not available for 28W T8 lamps. Voltage must be specified for Standard 010V 32W 3 and 4-lamp ballast. 4-lamp ballast versions must be 277V. Ballast Type EB8 =T8 Electronic Start. Total Harmonic Distortion < 10% EB8 /PLUS= T8 Electronic Start. Total Harmonic Distortion < 10%. High Ballast Factor > 1.15. ER8 = T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10% High Performance T8 Ballasts HB8 =T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Standard Ballast Factor .86 – .88 HB8 L=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Low Ballast Factor .77 – .82 HB8 N=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Normal Ballast Factor 1.0 HB8 H=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. High Ballast Factor 1.15 – 1.20 HR8 T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Standard Ballast Factor .86 – .88 HR8 DIM=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Step Dimming. Ballast Factor .88 HR8 L=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Low Ballast Factor .71 – .79 HR8 H=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. High Ballast Factor 1.15 – 1.20 Options FR=Fire Rated Label REP=Riveted End Plates PAF=Painted After Fabrication Packaging U=Unit Pack PAL=Job Pack, out of carton PALC=Job Pack, in carton 0-10V Dimming Ballasts (9) 5LTV8 =T8 0-10V Program Rapid Start. Total Harmonic Distortion < 10%. Ballast Factor 0.87 (12), (13) 5LTVS8 =T8 0-10V Spec Grade Program Rapid Start. Total Harmonic Distortion < 10%. Ballast Factor 0.87 (10), (11) Fifth Light DALI Ballasts (7) 5LT8 =T8 DALI Program Rapid Start. Total Harmonic Distortion < 10%. Ballast Factor 1.0 Number of Ballasts 1=1 Ballast 2=2 Ballasts 3=3 Ballasts Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. SHIPPING INFORMATION Catalog No. Wt. 2GC8-228T8A 2GC8-232A 2GC8-428T8A 2GC8-432A 20 lbs. 20 lbs. 20 lbs. 20 lbs. Visit our web site at www.cooperlighting.com Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 2/24/16 ADF091407