METALUX ® DESCRIPTION GC8 is a premium grade specification lensed troffer series. This innovative, high quality luminaire is dedicated to the latest T8 lamp and micro electronic ballast technology for optimal performance and energy efficiency. The GC8 is compatible with all of today’s popular ceiling systems and is available with a number of options and accessories for application versatility. Catalog # The GC8 series features efficiency, quality and performance. The series is an excellent choice for commercial office spaces, schools, hospitals or retail merchandising areas. Prepared by Type Project Date Comments SPECIFICATION FEATURES Construction Electrical Frame/Shielding Rigid housing is die formed of code gauge prime cold rolled steel and features full length dieformed stiffeners for added strength. Side flanges are hemmed. Innovative design provides superior lens brightness uniformity and visual comfort. Micro ballast cover*** reduces ballst shadow for superior lens brightness uniformity and is easily removed without tools. Die formed captive lampholder brackets fully enclose lampholder wiring permitting easy lampholder replacement. Heavy endplates are securely attached with interlocking tabs and screws. Four auxiliary fixture end suspension points provided. KOs for continuous row wiring. Endplates have integral Grid-lock feature for safety and convenience. Ballasts are CBM/ETL Class “P” and are positively secured by mounting bolts. Pressure lock lampholders. Biaxial models use 2G11 base lampholders with double-edge wiping action pressure-lock contacts and horizontally oriented lamp support clips.UL/CUL listed. Suitable for damp locations.** Die formed, heavy gauge, flat steel door with reinforced mitered corners and baked white enamel finish. Flat and regressed aluminum doors also available. Positive light seals. Light stabilized 100% virgin acrylic prismatic lens. Standard #12 pattern. Numerous additional shielding options available. Finish Multistage, iron phosphate pretreatment ensures maximum bonding and rust inhibition. Housing and ballast cover finished with new 90% reflective matte white enamel for superior performance. “PAF” Painted After Fabrication option also available. Hinging/Latching Positive Cam latch with baked white enamel finish. Safety-lock T-hinges allow hinging and latching either side. 2GC8 317 3U1-5/8 Controls Fifth Light ballast options are offered for both 0-10V continuous dimming and DALI applications. Combine with energy-saving products like occupancy sensors, daylighting controls, and lighting relay panels from Cooper Controls (www.coopercontrol.com) to maximize energy savings. 2' X 2' TROFFER 3 LAMPS Specification T8 Troffer New York City Rated 3-3/4" [95mm] ENERGY DATA Input Watts: EB Ballast & STD Lamps 317 (56), 3U1-5/8 (88) 23-3/4" [603mm] maximum overall nominal depth † ES Ballast & STD Lamps 317 (68), 3U1-5/8 (105) LAMP CONFIGURATIONS MOUNTING DATA 3-3/4" [95mm] 3-3/4" [95mm] X=5-3/8" [137mm] 23-3/4" [603mm] Luminaire Efficacy Rating LER = FL-47 Catalog Number: 2GC8-317 3U1-5/8 317 1-1/2" [38mm] X X=1-5/8" [41mm] X 23-3/4" [603mm] X X X 5-3/8" 5-3/8" [137mm] [137mm] 23-3/4" [603mm] Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $5.08 DOOR FRAMES GC8 F lat, White Steel 2-3/4" [70mm] 5-3/4" [146mm] GC8FA F lat, E xtruded White Alum inum GC8RA D eep, R egressed, E xtruded Natural Alum inum *Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements. 23-15/16" [610mm] **Consult Pre Sales Technical Support. ***Full sized ballast cover for biaxial lamps and emergency option. CEILING COMPATIBILITY G Grid/Lay-in Standard G Concealed T G Slot Grid F Flange Trim With Supporting Swing Gates Ceiling Type Trim Type Exposed Grid Concealed T Slot Grid Flange G G G F LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS Safe and convenient means of disconnecting power. (Verify compatibility/ consult factory.) COOPER LIGHTING ADF111080 NY2GC8 PHOTOMETRICS 2GC8-317A Electronic Ballast (3) F17T8/TL841/6 lamps 1300 lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.4 x mounting height Efficiency 77.1% Test Report: 2GC8317A.IES LER = FL-47 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $5.08 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 1143 1141 1127 1102 1067 1020 959 882 788 675 550 430 330 251 187 135 100 59 0 Across ⊥ 1143 1144 1142 1137 1125 1100 1061 1012 949 856 725 562 405 285 207 164 129 79 0 45° 1143 1140 1133 1119 1096 1063 1014 949 867 761 638 502 365 244 156 109 90 58 0 Coefficients of Utilization rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 92 81 71 63 56 51 46 41 38 35 32 92 78 66 57 50 44 39 35 32 29 26 92 75 62 52 45 39 34 30 27 24 22 90 82 75 69 63 58 54 50 47 44 41 90 79 70 62 55 50 45 41 37 34 32 90 76 65 56 49 43 39 35 31 28 26 90 74 61 52 45 39 34 30 27 24 22 Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 0-180 Lumens 914 1506 2536 3007 3007 %Lamp 23.4 38.6 65.0 77.1 77.1 Candela Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 1965 1956 1922 1866 1794 1703 1580 1431 1256 1050 827 654 506 386 279 212 155 83 0 Across ⊥ 1965 1968 1970 1970 1961 1923 1855 1754 1590 1356 1075 784 553 398 314 263 200 104 0 45° 1965 1962 1945 1916 1878 1815 1726 1606 1446 1228 1008 754 485 308 196 170 153 85 0 Coefficients of Utilization Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 92 84 77 71 65 60 56 52 48 45 42 2GC8-2BX40A Electronic Ballast F40BX/SPX35/IS lamps 3150 lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.4 x mounting height Efficiency 77.9% Test Report #ITL50232 LER = FL-65 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.70 Candela %Fixture 30.4 50.1 84.3 100.0 100.0 20% 50% 50 30 10 30% 50 30 10 50 86 76 67 60 53 48 44 40 36 34 31 82 73 65 58 52 47 42 39 35 33 30 79 70 62 56 50 45 41 38 35 32 30 86 73 63 55 48 43 38 34 31 28 26 86 71 60 51 44 38 34 30 27 24 22 82 71 61 53 47 42 37 34 30 28 25 82 69 59 50 43 38 33 30 27 24 22 10% 30 10 79 69 60 52 46 41 37 33 30 27 25 79 67 57 49 43 38 33 30 27 24 22 0% 0 77 66 56 48 41 36 32 28 25 23 21 Typical VCP Percentages Room Size (Ft.) 20 x 20 30 x 30 30 x 60 60 x 30 60 x 60 Height Along 8.5’ 10.0’ 67 71 61 64 51 55 62 66 52 55 Height Across 8.5’ 10.0’ 63 67 57 61 44 49 60 64 47 50 rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 93 85 78 72 66 61 57 53 49 46 43 93 82 72 64 58 52 47 43 39 36 33 93 79 68 59 51 45 40 36 33 30 27 93 76 63 54 46 40 36 32 28 26 23 91 83 76 70 65 60 55 51 48 45 42 91 80 71 63 57 51 46 42 39 36 33 91 77 67 58 51 45 40 36 33 30 27 91 75 63 53 46 40 35 32 28 26 23 20% 50% 50 30 10 30% 50 30 10 50 87 77 68 61 55 49 45 41 38 35 32 83 74 66 59 53 48 44 40 37 34 31 79 71 63 57 51 46 42 39 36 33 31 87 75 65 56 50 44 39 35 32 29 27 87 73 61 52 45 40 35 31 28 25 23 83 72 63 55 48 43 39 35 32 29 27 83 70 60 52 45 39 35 31 28 25 23 Zonal Lumen Summary Typical VCP Percentages Zone 0-30 0-40 0-60 0-90 0-180 Room Size (Ft.) 20 x 20 30 x 30 30 x 60 60 x 30 60 x 60 Lumens 1574 2582 4204 4906 4906 %Lamp 25.0 41.0 66.7 77.9 77.9 %Fixture 32.1 52.6 85.7 100.0 100.0 10% 30 10 79 70 61 54 47 42 38 34 31 29 26 Height Along 8.5’ 10.0’ 57 61 49 54 40 44 51 55 41 44 79 68 59 51 44 39 35 31 28 25 23 0% 0 78 67 57 49 43 37 33 29 26 24 22 Height Across 8.5’ 10.0’ 54 59 46 51 36 39 49 54 37 40 Visit our web site at www.cooperlighting.com Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 2/24/16 ADF111080 NY2GC8 ORDERING INFORMATION SAMPLE NUMBER: 2GC8-317A-120V-EB81-U Rating NY=New York City Rated (20 Gauge Riveted End Plates) Width 2=2' Width Trim Type G=Grid/Lay-in (1) (Standard) G=Concealed T G=Slot Grid F=Flange Trim Series C8=Specification T8 Troffer Standard=Flat White Steel Door (Leave Blank) FA=Flush White Extruded Aluminum c/w Spring Latch RA=Regressed White Extruded Aluminum FAN=Flush Natural Anodized Extruded Aluminum RAN=Regressed Natural Anodized Extruded Aluminum FAB=Flush Black Extruded Aluminum RAB=Regressed Black Extruded Aluminum (1) Number of Lamps (2) 3 Lamps (Not included) Wattage 17=17W T8 (24") U1-5/8=31W T8 (24") (6) Shielding A=#12 Acrylic Pattern A125=#12 Pattern Acrylic (.125" Thickness) A19/156=#19 Pattern Acrylic (.156" Thickness) DA=Dropped Dish Matte White Acrylic IMA48=Injection Molded Acrylic (.150" Thickness) PB1S=1/2" x 1/2" x 1/2" Silver Parabolic Louver (Styrene) Voltage (2) 120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-277 (3 Options GL=Single Element Fuse GM=Double Element Fuse Lamps=Lamps Installed Flex=Flex Installed EL=Emergency Installed (2) NOTES: An EQ Grid Clip is recommended for all 9/16" ceiling systems. Standard off-center ballast (3) compartment on 3-lamp fixtures. Not available when specifying emergencies, voltage must be specific. (4) (5) Consult Pre Sales Technical Support. For a complete listing of Fifthlight Technology products and other solutions (6) from Cooper Controls, visit www.coopercontrol.com. Fifthlight ballast option not available. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. Ballast Type EB8 =T8 Electronic Start. Total Harmonic Distortion < 10% EB8 /PLUS= T8 Electronic Start. Total Harmonic Distortion < 10%. High Ballast Factor > 1.15. ER8 = T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10% High Performance T8 Ballasts HB8 =T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Standard Ballast Factor .86 – .88 HB8 L=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Low Ballast Factor .77 – .82 HB8 N=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Normal Ballast Factor 1.0 HB8 H=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. High Ballast Factor 1.15 – 1.20 HR8 T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Standard Ballast Factor .86 – .88 HR8 DIM=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Step Dimming. Ballast Factor .88 HR8 L=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Low Ballast Factor .71 – .79 HR8 H=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. High Ballast Factor 1.15 – 1.20 Options PAF=Painted After Fabrication FR=Fire Rated Label MEP=Modified End Plate REP=Riveted End Plates LAO=Less Access Opening (4) RLS=Rotor-Lock Socket (T8 Lamps Only) Packaging U=Unit Pack PAL=Job Pack, out of carton PALC=Job Pack, in carton ACCESSORIES EQ-CLIP-U=T-BAR Safety Earthquake Clips (1) Fifth Light DALI Ballasts (5) 5LT8 =T8 DALI Program Rapid Start. Total Harmonic Distortion < 0%. Ballast Factor 1.0 Number of Ballasts 1=1 Ballast 2=2 Ballasts 3=3 Ballasts SHIPPING INFORMATION Catalog No. Wt. NY2GC8-3U1-5/8A NY2GC8-317A 19 lbs. 19 lbs. Visit our web site at www.cooperlighting.com Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 2/24/16 ADF111080