COOPER LIGHTING - METALUX ® DESCRIPTION The GCAML Series features a deep para-contoured fixture housing, high reflectivity and optimum lamp to lens spacing. The series produces total uniformity of light in the luminous area and is compatible with all of today’s popular ceiling systems and is available with a number of options and accessories for application versatility. Type Catalog # Project Date Comments The specification luminaire is designed to offer maximum efficiency and performance for today’s unique interior specifications. The GCAML Series is an excellent choice for commercial office spaces, schools, hospitals or retail merchandising areas. Prepared by SPECIFICATION FEATURES A…Construction B…Electrical* D…Hinging/Latching Deep para-contoured housing, die formed code gauge, prime cold rolled steel. Die embossed housing has full length die formed stiffeners for added strength. Deep “V” ballast/wireway cover, easily removed without tools. Die formed captive lampholder bracket fully encloses lampholder wiring permitting easy lampholder replacement. Heavy gauge endplates are securely attached with interlocking tabs and screws assure accurate row length without build-up. Ample KOs for continuous row wiring. Endplates have integral Grid-Lock feature for safety and convenience. Ballasts are CBM/ETL Class “P” and are positively secured by mounting bolts. Pressure lock lampholders. UL/CUL listed. Suitable for damp locations.** Positive cam action spring loaded, self locking, black steel latches. Safety-lock T-hinges allow hinging and latching either side. C…Finish E…Frame/Shielding Multistage, iron phosphate pretreatment ensures maximum bonding and rust inhibitor. Lighting grade, baked white enamel finish. Low brightness, 1-1/2" deep semi-specular/haze parabolic aluminum louver. Finish is anodic oxide coating. Accurate parabolic cells are held in place with inter-locking feature. Frameless, full floating effect louver assembly. Black reveal around entire perimeter of louver. (See Ordering Information). A B C 2GCAML 228T8 232 328T8 332 428T8 432 D E 4-5/8" [117mm] 2' X 4' TROFFER 2, 3 OR 4 T8 LAMPS S p e c i f i c a t i o n D e e p Tr o ff e r 23-3/4" [603mm] MOUNTING DATA 7/8" [22mm] K.O. (2) Access Plate 7/8" [23mm] K.O. (2) 7/8" [22mm] K.O. (4) Access Plate 7/8" [22mm] K.O. (2) 1-1/2" [38mm] 1-1/2" [39mm] 5-1/4" [134mm] 3-3/4" [95mm] 7-23/32" [197mm] 48" [1220mm] Luminaire Efficacy Rating LER = FP-57 Catalog Number: 2GCAML-332 5-1/4" [135mm] 3-3/4" [95mm] 7-23/32" [196mm] 48" [1219mm] Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.21 LAMP CONFIGURATIONS 4-5/8" [117mm] 4-5/8" [117mm] 1-1/2" [38mm] 10-3/4" [273mm] 23-3/4" [603mm] Input Watts: EB Ballast & STD Lamps 228T8 (48), 232 (55), 328T8 (67) 332 (81), 428T8 (93), 432 (113) 23-3/4" [603mm] 23-3/4" [604mm] ENERGY DATA 1-1/2" [38mm] X=4-3/4" [121mm] 4-5/8" [117mm] X X 5-3/4" [146mm] 1-1/2" [38mm] 23-3/4" [603mm] *Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements. 7" 7" [178mm] [178mm] 23-3/4" [603mm] **Consult Pre Sales Technical Support. CEILING COMPATIBILITY G Grid/Lay-in Standard G Concealed T COOPER LIGHTING G Slot Grid F Aluminum Flange Trim With Supporting Swing Gates MZ Modular Trim With Supporting Swing Gates Ceiling Type** Trim Type Exposed Grid Concealed T Slot Grid Flange Concealed “T” or ”Z“ Metal Pan G G G F MZ MZ LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS Safe and convenient means of disconnecting power. ADF020646 2GCAML PHOTOMETRICS Coeff icients of Utilization 2GCAML-332S613I Electronic Ballast FO32T8/35K Lamps 2800 Lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.7 x mounting height Efficiency 66.4% Test Report: 2GCAML332S613I.IES rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 79 74 68 63 58 53 48 45 79 71 64 57 51 45 40 36 79 69 60 52 46 39 35 30 79 67 57 49 42 35 30 26 41 32 26 23 37 28 23 19 35 26 20 17 77 72 67 61 56 51 47 43 Candela 20% 50% 50 30 10 30% 50 30 10 10% 50 30 10 0% 0 71 64 58 52 47 42 37 33 77 70 62 56 50 44 40 35 77 68 59 52 45 39 34 30 77 66 56 48 41 35 30 26 74 67 60 54 48 43 38 34 74 65 57 50 44 38 34 30 74 64 55 47 41 35 30 26 40 32 36 28 34 25 26 23 20 22 19 17 31 27 25 26 22 22 19 20 17 71 63 56 49 43 38 33 29 71 62 54 47 40 34 30 26 68 62 56 51 45 40 36 33 68 61 54 48 42 37 33 29 68 60 52 46 40 34 30 26 66 59 51 44 38 33 28 24 30 25 27 22 24 20 22 19 17 29 25 22 26 22 19 23 19 17 21 18 15 Zonal Lumen Summary Ty p i c a l V C P P e r c e n t a g e s Zone 0-30 0-40 0-60 0-90 0-180 Room Size (Ft.) 20 x 20 30 x 30 30 x 60 60 x 30 60 x 60 Lumens %Lamp 1572 2681 4912 5575 5575 18.7 31.9 58.5 66.4 66.4 %Fixture 28.2 48.1 88.1 100.0 100.0 Height Along Height Across 8.5’ 10.0’ 8.5’ 10.0’ 71 69 66 63 78 73 75 69 82 78 79 74 82 79 78 76 85 82 82 79 Angle Along II Across⊥ 1877 0 1868 5 1834 10 1786 15 1722 20 1643 25 1552 30 1447 35 1327 40 1190 45 1040 50 874 55 683 60 447 65 146 70 45 75 20 80 6 85 0 90 45° 1877 1870 1837 1848 1877 1889 1885 1811 1705 1608 1515 1268 856 540 261 59 24 7 0 1877 1877 1893 1992 2077 2114 2063 2032 2108 2040 1537 1024 969 843 245 65 25 6 0 LER = FP-57 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.21 ORDERING INFORMATION SAMPLE NUMBER: 2GCAML-232S613I-UNV-EB81-U Rating Blank= Standard NY=New York City Rated ATW-SW4= Chicago Rated Width 2=2' Width Trim Type G=Grid/Lay-in (Standard) (1) G=Concealed T G=Slot Grid F=Aluminum Flange Trim (5) MZ=Modular Trim EMZ=Modular Trim (Extended Swing Arm Series C=Specification Deep Troffer Air Supply A=Air Handling Floating Door, Black Reveal AV=Air Handling w/Directional Vanes B=Non-Air Handling Floating Door, Black Reveal Blank=No Vane Number of Lamps (2) 2, 3 or 4 lamps Wattage 28T8=28W T8 (48") (6) 32=32W T8 (48") Louver S=Silver W=White Cell Configuration 613=6 Rows of 13, 78 Cell 1329=13 Rows of 29, 377 Cell Louver Finish I=Semi-Specular/Haze MI=Specular/Mirrored (Low Iridescent) P=White Finish Voltage (3) 120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-277 (4) Options Options GL=Single Element Fuse Packaging GM=Double Element Fuse U=Unit Pack EL4=Emergency Lighting Self Contained PAL=Job Pack, PAF=Painted After Fabrication out of carton RIF1=Radio Interference Suppressor PALC=Job Pack, 20GA/REP=20 Gauge Riveted Endplates. in carton For use in New York City. RLS=Rotor-Lock Socket (T8 Lamps Only) Flex=Flex Installed (Reference Flex ordering information) EL=Emergency Installed Ballast Type (3) EB8 =T8 Electronic Instant Start. Total Harmonic Distortion < 10% No. of Ballast 1 or 2 EB8 /PLUS= T8 Electronic Instant Start. High Ballast Factor >1.13. No. of Total Harmonic Ballast Distortion < 10% 1 or 2 ER8 =T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10% No. of Ballast 1 or 2 Lamps Installed Blank=No Lamps Installed L8835=T8 Lamp, 28W and 32W, 3500K (6) L8841=T8 Lamp, 28W and 32W, 4100K (6) L8835HL=T8 Lamp, 32W, 3500K, 3100 Lumens L8841HL=T8 Lamp, 32W, 4100K, 3100 Lumens LCWE=Cool White Energy Saving Lamps L8730=F32T8 3000K L8735=F32T8 3500K L8741=F32T8 4100K (Additional options available. See Accessory Section) Option – Aluminum Flange Trim (5) Blank=SW (Single White) Type Color ‘S’ Single ‘N’ Natural ‘R’ In Row ‘W’ White ‘E’ End of Row HPT8 Ballast HB8 L=T8 Electronic Instant Start. Low Ballast Factor .77 HB8 =T8 Electronic Instant Start. Ballast Factor .88 HB8 N=T8 Electronic Instant Start. Normal Ballast Factor 1.0 HB8 H=T8 Electronic Instant Start. High Ballast Factor 1.15-1.2 HR8 DIM=T8 Electronic Program Start Step Dimming. Ballast Factor .88 HR8 L=T8 Electronic Program Start. Low Ballast Factor .77 HR8 =T8 Electronic Program Start. Ballast Factor .88 HR8 H=T8 Electronic Program Start. High Ballast Factor 1.15-1.2 Door Frame ML=Frameless Metal Parabolic ACCESSORIES EQ-CLIP-U=T-BAR Safety Earthquake Clips(1) SHIPPING INFORMATION Catalog No. (1) (2) (3) NOTES: An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per fixture. Standard off-center ballast on 3-lamp fixtures. Products also (4) (5) available in non-US voltages and frequencies for international markets. Not available when specifying emergencies, voltage must be specific. Specify row configu(6) ration, type in catalog number when ordering complete fixture. When utilizing 28W T8 lamps, HPT8 Ballast must be speficied. For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. Wt. 2GCAML-232S613I 2GCAML-232S715I 2GCAML-332S613I 2GCAML-332S715I 2GCAML-432S613I 2GCAML-432S715I 48 lbs. 48 lbs. 48 lbs. 48 lbs. 48 lbs. 48 lbs. Visit our web site at www.cooperlighting.com Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 1/11 ADF020646