Fail-Safe D ES C R IPTION This architectural, recessed patient room light offers both exam and ambient lighting in one streamlined fixture. The MAE features innovative optical technology which provides powerful, focused illumination for examinations. Its unique design directs the light onto the bed and provides glare-free illumination for both the healthcare professional and patient. An architecturally styled design helps bring a relaxed, comfortable feel to any patient room environment. Type Catalog # Project Date Comments Prepared by SPE C IFIC A TION FEA T U R E S Application L e ns Fin ish The MAE is designed for use in healthcare facilities, specifically for use in patient rooms, exam rooms, and recovery areas to facilitate examinations and general tasks required by both patient and medical professional. Exam: Linear, ribbed acrylic side lenses. 0.100" thick on ends; prisms are located on the inside for easy cleaning. Ambient: Linear ribbed, 0.100" thick. Optional clear acrylic with performated inlay. Matte white, electrostatically applied, white powder coat finish, average minimum reflectance 92%. Optional anti-microbial matte white finish. H ou s i n g L a mps Electronic Class P, CBM/ETL ballast. 20 gauge steel. T8, T5 and T5HO linear fluorescent and long twin-tube lamps. Labels B allast UL/cUL listed for damp locations. MAE 2x2 2x4 MAE – T5 Ambient Exam Reading Wipe Down Door Vandal Resistant Door 5" [127mm] EXAM AMBIENT EXAM 24" [601mm] MAE – T8 5" [127mm] AMBIENT EXAM EXAM 24" [601mm] EXAM: 2 or 4 total T5, T5HO, T8. 2 total long twin-tube (BX) AMBIENT: 1, 2 or 3 lamps total; T5, T5HO, or T8 1 or 2 lamps total; long twin-tube (BX) ADF091704 2016-02-09 10:12:51 M AE ORDER IN G INFOR M A TION S A M P L E N U M B E R : M A E - G - 2 3 2 / 4 3 2 - U N V - E B 8 2 - SRL1L (Fixture) Product Family MAE =Medical Ambient Exam Light 5, 10 Mounting G=9/16", 1" or 1-1/2" T-bar grid For Flange (sheet-rock, hard-lid ceilings, specify the following, shipped separately: 2' x 2': DFCL2424W-U 4 2' x 4': DFCL2448W-U 4 SMR16LED53/7/30/9/36 (Lamp) Ambient Lamp Type (Center Lens) 2' x 2' 6, 8 214T5=(2) 14W T5 Lamps 314T5=(3) 14W T5 Lamps 224T5=(2) 24W T5 Lamps 324T5=(3) 24W T5 Lamps 217=(2) 17W T8 Lamps 317=(3) 17W T8 Lamps 240BX=(2) 40W Biax Lamps ExamLamp Type (Total # of Lamps) (Side Lenses) 2' x 2' 6, 8 214T5=(2) 14W T5 Lamps 414T5=(4) 14W T5 Lamps 224T5=(2) 24W T5 Lamps 424T5=(4) 24W T5 Lamps 217=(2) 17W T8 Lamps 417=(4) 17W T8 Lamps 240BX=(2) 40W Biax Lamps 2' x 4' 228T5=(2) 28W T5 Lamps 328T5=(3) 28W T5 Lamps 254T5=(2) 54W T5 Lamps 354T5=(3) 54W T5 Lamps 232=(2) 32W T8 Lamps 332=(3) 32W T8 Lamps 2' x 4' 228T5=(2) 28W T5 Lamps 428T5=(4) 28W T5 Lamps 254T5=(2) 54W T5 Lamps 454T5=(4) 54W T5 Lamps 232=(2) 32W T8 Lamps 432=(4) 32W T8 Lamps Notes: 1 Please specify dimming ballast catalog number. 2 When choosing emergency battery pack, dedicated voltage must be specified. Ambient lamp only. Not available in all configurations. Please consult factory. Voltage 120=120V 277=277V 347=347V UNV=120V-277V Lamp Shield - Ambient Linear Ribbed Frosted Acrylic (Leave Blank) Ballast (Ambient/Exam) EB51=(1) T5 ballast EB52=(2) T5 ballasts EB53=(3) T5 ballasts 8 EB81=(1) T8 ballast EB82=(2) T8 ballasts EB83=(3) T8 ballasts EBX1=(1) Biaxial ballast EBX2=(2) Biaxial ballasts Dimming 1 3 The switching device is to be normally-open, momentary contact switch. Activation of the contact provides the following illumination scenarios: Ambient only - on, Exam only - on, Ambient and Exam - on, Ambient and Exam - off. Other switching options available; contact factory. 4 For flange (hard lid, sheetrock) application, specify the Drywall Framing Kit (DF-22-W-U or DF-24-W-U). Order the appropriate Germ Guard Door with grid MAE fixture. Ceiling cutout dimensions: 2' x 2'=24-3/8" x 24-3/8"; 2' x 4'= 24-3/8" x 48-3/8". 5 Fixture not suited for continuous row applications. Fixture length exceeds 24" (2' x 2') and 48" (2' x 4'). 6 For MAE 2' x 2', up to 3 ballasts can be specified. 2' x 2' fixture with multiple ballasts and a combination of EM, RIF, EM, RIF, LVCP, LED Reading Lights - will require back-box to mount electrical. 2" additional height. Please consult Technical Support prior to ordering. 7 The switching device is to be a normally open, momentary contact switch. Activation of the contact provides on/off switching operation. 8 2' x 2' fixture with (5) T5 or T5HO lamps requires 3 ballasts which requires back-box and additional fixture height of 2". 9 For (3) ballasts, LVCP connection must be defined. Please contact Fail-Safe Technical Support for ordering information. 10 Hard metric sizes available. Consult factory for ordering information. 11 Must specify voltage. 12 Other LVCP configurations include: Low volate controller controlling reading lamps and ambient -LVCP/IB/LRL2 Low voltage controller controlling LRL1L (one-circuit) and LRL1R (second circuit) -LVCP/LRL1L/LRL1R 13 SRL is socket (GU5.3), hardware, and transformer for LED lamp. Order lamp on separate line item. SRL LED Lamps Wattage Color Temp CRI SMR16LED53 7=7.5W 9=90 10=10° 25=25° 36=36° 27=2700K 30=3000K LVCP=Low Voltage Controller 3, 9, 11, 12 Load 1 = Inboard (ambient) Load 2 = Outboard (exam) LVCP/IB=Low Voltage Controller, Inboard (ambient) control only. Outboard (exam) seperate circuit 7, 11, 12 LVCP/OB=Low Voltage Controller, Outboard (exam) control only. Inboard (ambient) seperate circuit 7, 11, 12 EL4=EM Pack, T8, BX 2 EL5=EM Pack, T5, T5HO 2 GLR=Fuse Holder RIF=Radio Interference Filter AM=Antimicrobial Finish (all painted parts) SRL1L=Socket, hardware and transformer for one MR16 LED lamp, 7.5W max. Separate circuit default, lamps ordered on separate line item. Left hand orientation 13 SRL1R=Socket, hardware and transformer for one MR16 LED lamp, 7.5W max. Separate circuit default, lamps ordered on separate line item. Right hand orientation 13 SRL2/1C=Sockets, hardware and transformer for two MR16 LED lamps, 7.5W max. Separate circuit, independent of the linear LED modules. Lamps ordered on separate line item 13 SRL2/2C=Sockets, hardware and transformers (2) for two MR16 LED lamps, 7.5W max. Separate two circuits, independent of the linear LED modules. Lamps ordered on separate line item 13 WDDCPH=Wipe-Down Door, Clear Acrylic 0.125” Thick, Continuous Piano Hinge, Matte White Anti-microbial Paint VRDCPH=High Abuse Door, Inset, 0.187” Thick, Clear Polycarbonate, Stainless Steel Continuous Piano Hinge, (6) Tamper Resistant Screws Accessories (order separately) MSC4-PK=Mounting Security Clips. Use secure fixture to grid or to attach tie-wires' DFCL-2448W-U*=2' x 4' gasketed drywall framing kit. Ships with gasket to be applied in field. Cut out dimension 24.25” x 48.25” DFCL-2424W-U*=2' x 4' gasketed drywall framing kit. Ships with gasket to be applied in field. Cut out dimension 24.25” x 24.25” * Change W to AMW for antimicrobial matte white finish SRL LED Lamps (order separately) Example: SMR16LED53/7/27/9/36 or SMR16LED53/7/30/9/25 Number/ Orientation Options Beam Angle SRL1L SRL1R SRL2 (Two Reading Lights) LED Lamps ordered on seperate line item Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting Specifications and dimensions subject to change without notice. ADF091704 2016-02-09 10:12:51