D esc r ip tion
Fail-Safe's HDF high pressure hose down luminaire's sealed tubular
design withstands water penetration, even when subjected to a 1200 PSI
high pressure hose down test. Stainless steel hardware provides a watertight seal by compressing a high impact resistant tube between two fully
gasketed end plates. Water-tight connectors ensure the integrity of the
seal at the point of power supply. The ballast channel is constructed of
non-corrosive aluminum. An emergency battery pack is available as an
option. UL/cUL listed for wet locations, and manufactured in accordance
with NSF standards.
®
Type
Catalog #
Project
Date
Comments
Prepared by
S pec if ic a tion Fea t u r e s
Mounting
Re fl e c tor
Fin ish
Stainless steel sash chain and
S-hooks available. Heavy duty
stainless steel surface/wall
mounting bracket optional.
Heavy gauge aluminum reflector
finished with high reflectance white
powder coat paint.
High gloss, electrostatically
applied, white powder coat finish,
average minimum reflectance 92%.
L e ns
B allast
High impact resistant, DR blended
(50%) acrylic tube.
Electronic Class P, CBM/ETL
ballast.
L a mps
Labels
(By Others)
UL/cUL listed for wet locations.
End-Cap
1/2" thick opaque PVC endcaps are
fully sealed with closed cell silicone
gasketing.
Connector
Five-foot, three-wire cord and
water-tight connector is standard.
Other cord lengths are available.
Ba l l a s t Cha nnel
HDF
Heavy gauge aluminum ballast
channel and stainless steel ballast
channel end plate.
Cleanroom / Food Processing
1200 PSI Hosedown
6 3/4" dia.
[171 mm]
97 1/4" Overall
[2470 mm]
Mounting Access o r i e s
Energy Data
Stainless Steel Sash Chain
S-hook and Bracket
Surface Mount
(breakout height = 5 1/2")
Chain Mounting Bracket
Specifications and dimensions subject to change without notice.
Consult your representative for additional options and finishes.
For Energy Management related
technical data to support the
performance of this fixture series,
refer to Ordering Information section
for input wattages
ADC041006
2012-12-07 14:25:27
H DF
Or der ing I nf or m a tion
SAMPLE NUMBER: HDF-214-120-EB51-EBP-SMB
Series
Lamp Type
Voltage 1
Ballast
Accessories
(Order separately)
Options
HDF
HDF=Hose Down
Fluorescent
2' Nom. Length
T5 Lamp
214= (2) 14W T5 Lamps
117= (1) 17W T8 Lamp
217= (2) 17W T8 Lamps
224= (2) 24W T8 Lamps
120= 120V
277= 277V
347= 347V
UNV= 120-277V
4' Nom. Length
128= (1) 28W T5 Lamp
154= (1) 54W T5 Lamp
228= (2) 28W T5 Lamps
254= (2) 54W T5 Lamps
132= (1) 32W T8 Lamp
232= (2) 32W T8 Lamps
140= (1) 40W T12Lamp
148T8HO= (1) 44W T8HO Lamp
248T8HO= (2) 44W T8HO Lamps
Electronic Ballast 2
EB81= (1) Ballast for use
with T8 Lamp
EB82= (2) Ballasts for use
with T8 Lamp
EB51= (1) Ballast for use
with T5 Lamp
EB52= (2) Ballasts for use
with T5 Lamp
EB21= (1) Ballast for use
with T12 Lamp
EB22= (2) Ballasts for use
with T12 Lamp
8' Nom. Length (Total No. of Lamps)
428= (4) 28W T5 Lamps
432= (4) 32W T8 Lamps
454= (4) 54W T5 Lamps
159= (1) 59W T8 Lamp
259= (2) 59W T8 Lamps
186= (1) 86W T8HO Lamp
286= (2) 86W T8HO Lamps
EBP=Emergency Battery Pack
GLR=Fuse and Holder
Z=Low Temperature Starting Ballast
LL=Lamps Included
DWC-X =Quick Disconnect
Power Cord
(X=Cord Length) 3
SMB=Surface Mounting Bracket Kit
CMB=Chain Mounting Bracket Kit
SCHN1=(2) pieces of Sash Chain
(12" Length), (2) “S” Hooks,
(2) Stainless Steel Brackets.
For chain length, specify SCHN2
NOTES:
1 Products also available in non-US voltages and 50Hz for international
markets. Consult factory for availability and ordering.
2 For specific electronic ballasts, specify brand name and catalog number.
3 Consult factory for cord length options and availability.
Photom etr ics
Candlepower Distribution
1200
600
400
200
Test No.9078.0
HDF-2110
Lamp=(2) 110WT12
Lumens=9200
Spacing Criteria
=1.4 =1.3
Efficiency=70.9%
Zonal Lumen Summary
Av e r a g e
Luminance
Deg.
45
55
65
75
85
7611
7546
7246
6523
6178
Zone
0-30
0-40
0-60
0-90
90-180
0-180
7949
7398
6180
3900
1348
Lumens
2610
4355
8160
8526
0
13045
%Lamp
14.2
23.7
44.3
67.7
0.0
70.9
%Luminaire
20.0
33.4
62.6
100.0
0.0
100.0
50
25
C o e f fi c i e n t o f U t i l i z a t i o n
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
70
50
80%
30
10
50
30
70%
10
50
10
50%
50
83
83
83
83
80
80
80
75
75
71
67
64
68
65
62
64
67
61
56
52
59
54
50
55
61
54
48
43
52
46
42
49
56
47
41
36
46
40
35
43
51
41
35
30
40
34
29
38
47
37
30
26
36
30
25
34
43
33
27
22
32
26
22
30
39
30
23
19
29
23
19
27
36
26
20
16
26
20
16
24
34
24
18
14
23
18
14
22
rc=Ceiling reflectance, rw=Wall reflectance, RCR=Room cavity ratio
CU Data Based on 20% Effective Floor Cavity Reflectance.
75
59
48
40
34
28
24
21
18
16
14
30%
50
10
70
60
52
46
40
36
32
29
26
23
21
10%
10
70
56
46
39
33
27
24
20
18
15
13
Specifications and dimensions subject to change without notice.
Fail-Safe • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
0%
0
65
56
49
43
38
34
30
27
24
22
20
65
53
44
37
31
26
23
20
17
15
13
63
51
42
35
30
25
21
18
16
13
12
ADC041006
2012-12-07 14:25:27
Download