fAIL-sAFE D esc r ip tion Fail-Safe's HDF high pressure hose down luminaire's sealed tubular design withstands water penetration, even when subjected to a 1200 PSI high pressure hose down test. Stainless steel hardware provides a watertight seal by compressing a high impact resistant tube between two fully gasketed end plates. Water-tight connectors ensure the integrity of the seal at the point of power supply. The ballast channel is constructed of non-corrosive aluminum. An emergency battery pack is available as an option. UL/cUL listed for wet locations, and manufactured in accordance with NSF standards. ® Type Catalog # Project Date Comments Prepared by S pec if ic a tion Fea t u r e s Mounting Re fl e c tor Fin ish Stainless steel sash chain and S-hooks available. Heavy duty stainless steel surface/wall mounting bracket optional. Heavy gauge aluminum reflector finished with high reflectance white powder coat paint. High gloss, electrostatically applied, white powder coat finish, average minimum reflectance 92%. L e ns B allast High impact resistant, DR blended (50%) acrylic tube. Electronic Class P, CBM/ETL ballast. L a mps Labels (By Others) UL/cUL listed for wet locations. End-Cap 1/2" thick opaque PVC endcaps are fully sealed with closed cell silicone gasketing. Connector Five-foot, three-wire cord and water-tight connector is standard. Other cord lengths are available. Ba l l a s t Cha nnel HDF Heavy gauge aluminum ballast channel and stainless steel ballast channel end plate. Cleanroom / Food Processing 1200 PSI Hosedown 6 3/4" dia. [171 mm] 97 1/4" Overall [2470 mm] Mounting Access o r i e s Energy Data Stainless Steel Sash Chain S-hook and Bracket Surface Mount (breakout height = 5 1/2") Chain Mounting Bracket Specifications and dimensions subject to change without notice. Consult your representative for additional options and finishes. For Energy Management related technical data to support the performance of this fixture series, refer to Ordering Information section for input wattages ADC041006 2012-12-07 14:25:27 H DF Or der ing I nf or m a tion SAMPLE NUMBER: HDF-214-120-EB51-EBP-SMB Series Lamp Type Voltage 1 Ballast Accessories (Order separately) Options HDF HDF=Hose Down Fluorescent 2' Nom. Length T5 Lamp 214= (2) 14W T5 Lamps 117= (1) 17W T8 Lamp 217= (2) 17W T8 Lamps 224= (2) 24W T8 Lamps 120= 120V 277= 277V 347= 347V UNV= 120-277V 4' Nom. Length 128= (1) 28W T5 Lamp 154= (1) 54W T5 Lamp 228= (2) 28W T5 Lamps 254= (2) 54W T5 Lamps 132= (1) 32W T8 Lamp 232= (2) 32W T8 Lamps 140= (1) 40W T12Lamp 148T8HO= (1) 44W T8HO Lamp 248T8HO= (2) 44W T8HO Lamps Electronic Ballast 2 EB81= (1) Ballast for use with T8 Lamp EB82= (2) Ballasts for use with T8 Lamp EB51= (1) Ballast for use with T5 Lamp EB52= (2) Ballasts for use with T5 Lamp EB21= (1) Ballast for use with T12 Lamp EB22= (2) Ballasts for use with T12 Lamp 8' Nom. Length (Total No. of Lamps) 428= (4) 28W T5 Lamps 432= (4) 32W T8 Lamps 454= (4) 54W T5 Lamps 159= (1) 59W T8 Lamp 259= (2) 59W T8 Lamps 186= (1) 86W T8HO Lamp 286= (2) 86W T8HO Lamps EBP=Emergency Battery Pack GLR=Fuse and Holder Z=Low Temperature Starting Ballast LL=Lamps Included DWC-X =Quick Disconnect Power Cord (X=Cord Length) 3 SMB=Surface Mounting Bracket Kit CMB=Chain Mounting Bracket Kit SCHN1=(2) pieces of Sash Chain (12" Length), (2) “S” Hooks, (2) Stainless Steel Brackets. For chain length, specify SCHN2 NOTES: 1 Products also available in non-US voltages and 50Hz for international markets. Consult factory for availability and ordering. 2 For specific electronic ballasts, specify brand name and catalog number. 3 Consult factory for cord length options and availability. Photom etr ics Candlepower Distribution 1200 600 400 200 Test No.9078.0 HDF-2110 Lamp=(2) 110WT12 Lumens=9200 Spacing Criteria =1.4 =1.3 Efficiency=70.9% Zonal Lumen Summary Av e r a g e Luminance Deg. 45 55 65 75 85 7611 7546 7246 6523 6178 Zone 0-30 0-40 0-60 0-90 90-180 0-180 7949 7398 6180 3900 1348 Lumens 2610 4355 8160 8526 0 13045 %Lamp 14.2 23.7 44.3 67.7 0.0 70.9 %Luminaire 20.0 33.4 62.6 100.0 0.0 100.0 50 25 C o e f fi c i e n t o f U t i l i z a t i o n rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 70 50 80% 30 10 50 30 70% 10 50 10 50% 50 83 83 83 83 80 80 80 75 75 71 67 64 68 65 62 64 67 61 56 52 59 54 50 55 61 54 48 43 52 46 42 49 56 47 41 36 46 40 35 43 51 41 35 30 40 34 29 38 47 37 30 26 36 30 25 34 43 33 27 22 32 26 22 30 39 30 23 19 29 23 19 27 36 26 20 16 26 20 16 24 34 24 18 14 23 18 14 22 rc=Ceiling reflectance, rw=Wall reflectance, RCR=Room cavity ratio CU Data Based on 20% Effective Floor Cavity Reflectance. 75 59 48 40 34 28 24 21 18 16 14 30% 50 10 70 60 52 46 40 36 32 29 26 23 21 10% 10 70 56 46 39 33 27 24 20 18 15 13 Specifications and dimensions subject to change without notice. Fail-Safe • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801 0% 0 65 56 49 43 38 34 30 27 24 22 20 65 53 44 37 31 26 23 20 17 15 13 63 51 42 35 30 25 21 18 16 13 12 ADC041006 2012-12-07 14:25:27