Catalog # Type

advertisement
CORELITE
DESCRIPTION
Corelite's Traverse Wall Mount is an asymmetric semi-indirect fluorescent
luminaire that features a rugged aluminum construction and sleek modern
styling. The concave perf aluminum insert creates a subtle sparkle while
offering the awareness of the light source. The Traverse Wall may be
mounted over standard 2"x4" J-Boxes for individual or continuous
configuration using 4' and 8' modular sections. The Traverse Wall is suited
for open office perimeters, private offices, conference rooms, corridors and
public spaces.
Type
Catalog #
Project
Date
Comments
Prepared by
SPECIFICATION FEATURES
A ... Construction
Housing is 6063 T5 aluminum
extrusion forming a 2-7/8"
rectangular profile. Standard 4'-0"
and 8'-0" fixture lengths combine
for continuous runs.
D ... Reflectors
Reflector pan is painted with a
highly reflectance white powder
coat finish. Optional die-formed
side reflector is a highly specular
anodized aluminum.
B ... End Caps
Standard end caps are precision
die-cast aluminum, mechanically
attached without exposed
fasteners.
E ... Electrical
Fixtures are prewired with quick
wire connectors and use UL listed
Class P, 265ma T8 instant start
universal voltage electronic
ballasts. Power factor of 95% with
less than 10% THD. Fixtures and
electrical components certified to
UL and CUL standards.
C ... Louver
Semi-specular material, perforated
section is 15% open with 0.062"
diameter holes and opal diffuser.
A
C
F ... Finish
Fixture housings are standard
white using electrostatically
applied polyester powder coat
paint.
Mounting
Fixture mounts directly to existing
structure over a 2" x 4" standard
electrical box mounted horizontally
into the wall. Refer to installation
section for details.
C o n c a v e Me ta llic P e r f
Traverse Wall
2T8
E
D
Wall Mount
B
F
Semi-Indirect
Light Distribution
Indirect - 94.5%
Direct - 5.5%
2-7/8"
[73mm]
6-7/8" [174mm]
1-1/4" [31mm]
End Cap Side View
MODULES AND DIMENSIONS*
48" [1219mm]
96" [2438mm]
*Dimensions do not include end caps.
ORDERING INFORMATION
Sample Number: TW-WC-2T8-1C-UNV-SU-WA-8
Series
TW=Traverse
Wall
Optics Up
S=Specular
W=White
Optics Down
C=Concave Metallic Perf
Number of
Lamps
2=2 Lamps
Lamp Type
T8=T8 Normal Output
Number of Circuits
1=1 Circuit
1
2=2 Circuits
Wiring 1
B=Battery Pack
Voltage 1
120=120V
Suspension
SU-WA=Surface/Wall Mount
C=Standard Circuit
D=Dimming
277=277V
347=347V
Run Length
E=Emergency
T=Nightlight
UNV=Universal
(120V277V)
Continuously Mounted
Y=Daylight
Notes: 1
Individually Mounted
Luminaires may be 4' or 8' in length
Standard row configurations over 8'
consist of 4' and 8' sections
Not all options available. Please consult your Cooper Lighting Representative for
availability.
Specifications and Dimensions subject to change without notice.
Consult your representative for additional options and finishes.
ADE071102
01/20/2009 1:11:03 PM
PHOTOMETRICS
Corelite
Candela
Coefficients of Utilization
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
TW-WC-2T8
(2) F32T8/TL841
3000 Lumens
20%
10
50%
50 30 10
30%
50 30 10
10%
50 30 10
70
70
70
70
60
60
60
60
43
43
43
26
26
26
11
11
11
64
58
53
48
61
53
47
41
58
49
42
36
56
45
38
32
55
50
45
41
53
46
40
36
50
42
36
31
48
39
33
28
37
32
29
25
36
30
26
22
35
28
24
20
23
20
18
16
22
19
16
14
22
18
15
13
10
09
08
07
09
08
07
06
09
08
07
06
44
40
37
34
36
32
29
26
31
27
24
21
27
23
20
17
38
35
32
29
31
28
25
23
27
23
21
18
24
20
17
15
22
20
18
16
19
17
15
13
17
15
13
11
14
12
11
10
12
11
09
08
11
09
08
07
06
05
05
04
05
05
04
04
05
04
04
03
32
29
23
21
18
16
15
13
27
25
20
18
16
14
13
12
15
13
12
10
10
08
09
08
07
07
06
05
04
04
03
03
03
02
0%
0
Angle
0
Along II
82
45o
82
Across I
82
5
82
82
81
15
25
79
74
77
71
78
72
35
45
55
65
52
42
61
53
42
66
58
46
02
02
02
01
65
75
85
90
28
13
3
0
32
20
5
0
35
23
8
0
01
01
01
95
105
115
42
234
454
91
386
716
97
397
727
125
135
145
155
165
175
666
860
1027
1157
1247
1293
952
1091
1206
1271
1311
1315
1042
1231
1307
1349
1346
1324
180
1300
1300
1300
04
03
03
02
Efficiency 72.6%
Test Report
#LSI17913
Zo nal Lumen Summar y
Luminance Data
Zone
0-30
0-40
Lumens
63
104
%Lamp
1.06
1.74
%Fixture
1.47
2.40
Angle
in Deg
45
0-Deg
cd/sm
1013
45-Deg
cd/sm
1038
90-Deg
cd/sm
1125
0-60
0-90
40-90
184
238
134
3.08
3.97
2.23
4.24
5.48
3.08
55
65
75
999
905
715
999
1037
1068
1111
1157
1210
60-90
90-180
0-180
53
4115
4353
.90
68.59
72.56
1.23
94.52
100.00
85
562
922
1359
COMMON CIRCUIT CONFIGURATIONS
1C=Single circuit luminaire
1E=Single circuit luminaire with emergency circuit (generator)
1C
1B=Single circuit luminaire with battery pack
48"(1219mm)
=Circuit 1
=Emergency Circuit
1E
=Battery Circuit
96"(2438mm)
=Power Mount
1B
=Non-Power Mount
96"(2438mm)
48"(1219mm)
STANDARD ROW CONFIGURATIONS
FIXTURE
LENGTH
4'
4'
1
8'
8'
12'
16'
1
1
1
20'
24'
1
2
2
28'
32'
1
3
3
36'
40'
1
4
4
44'
48'
1
5
5
52'
56'
1
6
6
60'
64'
1
7
7
68'
72'
1
8
8
76'
80'
1
9
9
84'
88'
1
10
10
Specifications and Dimensions subject to change without notice.
Corelite • 18001 E. Colfax Ave. • Aurora, CO 80011 • 303.393.1522 • FAX 303.393.1477
92'
96' 100' 104' 108'
1
11
11
1
12
12
1
13
13
ADE071102
01/20/2009 1:11:03 PM
Download