Catalog # Type

advertisement
CORELITE
DESCRIPTION
Corelite's Class A Indirect Wall Mount is an indirect fluorescent luminaire
with an engineered optical system, which provides an asymmetric forward
throw distribution. The Class A Indirect Wall may be mounted over standard
2"x4" J-Boxes for individual or continuous configurations using 4', 8' and 12'
modular sections. The Class A Indirect Wall is suited for open office
perimeters, private offices, conference rooms, corridors and public spaces.
Type
Catalog #
Project
Date
Comments
Prepared by
SPECIFICATION FEATURES
A ... Construction
Housing is one piece die-formed
cold rolled steel, forming a 6" x 2
7/8" architectural profile. Standard
4'-0", 8'-0" and 12'-0" fixture
lengths combine for continuous
runs.
B ... End Plates
Standard laser cut 14-gauge cold
rolled steel, mechanically attached
with no exposed fasteners.
Optional die-cast aluminum end
caps also available.
F
A
D
C ... Reflectors
Die-formed reflectors are highly
specular anodized aluminum.
D ... Electrical
Fixtures are prewired with quick
wire connectors and use UL listed
Class P, 265ma T8 instant start
universal voltage electronic
ballasts. Power factor of 95% with
less than 10% THD. Fixtures and
electrical components certified to
UL and CUL standards.
C
E ... Finish
Fixture housings are standard
white using electrostatically
applied polyester powder coat
paint.
F ... Mounting
Fixture mounts directly to existing
structure over a 2" x 4" standard
electrical box mounted horizontally
into the wall. Refer to installation
section for details.
E
B
2-7/8"
[73mm]
F LAT E ND P LAT E (S tandard)
1/8"
[3mm]
6" [152mm]
Class A
Indirect Wall
6.5" [165mm]
E T =T AP E R E D E ND C AP
MO DUL E S
AND
DIME NS IO NS *
2T8
5"
[127mm]
48" [1219mm]
96" [2438mm]
Wall Mount
Full Indirect
E R =R OUNDE D E ND C AP
Light Distribution
144" [3658mm]
Indirect - 100.0%
Direct - 0.0%
2-1/4"
[57mm]
*Dimens ions do not include end plates .
ORDERING INFORMATION
Sample Number: AW-SN-2T8-1C-277-SU-WA-32-ET
Series
AW=Class A
Indirect Wall
Mount
Optics Up
S=Specular
Optics Down
N=None
Number of
Lamps
2=2 Lamps
Lamp Type
T8=T8 Normal Output
Number of Circuits
1=1 Circuit
2=2 Circuits
1
Wiring 1
B=Battery Pack
Voltage 1
120=120V
C=Standard Circuit
D=Dimming
277=277V
347=347V
E=Emergency
T=Nightlight
UNV=Universal
(120V277V)
Y=Daylight
Suspension
SU-WA=Surface/Wall
Mount
Options
ER=Rounded End
Cap
ET=Tapered End Cap
Run Length
Individually Mounted
Luminaires may be 4', 8',
or 12' in length
Continuously Mounted
Standard row
configurations over 12'
consist of 8' and 12'
sections
Notes: 1
Not all options available. Please consult your Cooper Lighting Representative for availability.
Specifications and Dimensions subject to change without notice.
Consult your representative for additional options and finishes.
ADE032235
01/20/2009 1:01:01 PM
PHOTOMETRICS
Corelite
C o e f f i c i e n ts
C andela
E ffec tive floor c avity reflec tanc e
80%
70%
rc
rw
RCR
A W-S N-2T 8
(2) F 32T 8/T L841
3000 Lumens
o f U ti l i z a ti o n
50%
30%
10%
A long II
45
180
882
882
A c ros s I
882
70
50
30
10
70
50
30
10
50
30
10
50
30
10
50
30
10
0
175
170
863
854
931
967
952
1014
0
1
50
46
50
43
50
42
50
40
43
39
43
37
43
36
43
34
29
25
29
25
29
24
17
15
17
14
17
14
05
05
05
05
05
04
00
00
165
160
840
817
1004
1032
1072
1126
2
3
4
5
41
38
34
31
38
33
29
25
35
30
25
22
32
27
23
19
35
32
29
27
32
28
25
22
30
26
22
19
28
23
20
17
22
20
17
15
21
18
15
13
19
16
14
12
13
11
10
09
12
11
09
08
11
10
08
07
04
04
03
03
04
03
03
03
04
03
03
02
00
00
00
00
155
150
145
140
790
757
719
674
1057
1071
1081
1078
1178
1220
1239
1245
6
7
8
9
29
27
24
23
23
21
19
17
19
17
15
13
16
14
12
11
25
23
21
19
20
18
16
14
17
15
13
11
14
12
11
09
14
12
11
10
12
10
09
08
10
09
08
07
08
07
07
06
07
06
05
05
06
05
04
04
03
02
02
02
02
02
02
02
02
02
01
01
00
00
00
00
135
130
125
120
623
568
508
442
1055
1018
957
841
1231
1143
1013
859
10
21
15
12
09
18
13
10
08
09
07
06
05
04
03
02
01
01
00
115
371
695
646
110
105
293
205
509
316
472
319
100
95
90
114
38
0
170
34
0
176
9
0
E fficiency 52.7%
T es t R eport
#LS I14065
o
A ngle
0%
20%
Zonal L umen S ummary
180-150
180-140
180-120
Zone
L umens
720
1221
2347
%L amp
12.00
20.36
39.12
%F ixture
22.79
38.66
74.30
180-90
140-90
120-90
3159
1937
811
52.66
32.30
13.53
100.00
61.34
25.70
0-90
0-180
0
3159
0.00
52.66
0.00
100.00
COMMON CIRCUIT CONFIGURATIONS FOR TWO LAMP SUSPENDED FIXTURE
2C =T wo circuit luminaire
2E =T wo circuit luminaire with emergency circuit
2C
1B =S ingle circuit luminaire with battery pack
48"(1219mm)
=C ircuit 1
=C ircuit 2
2E
=E mergency C ircuit
=B attery C ircuit
96"(2438mm)
=P ower Mount
1B
=Non-P ower Mount
96"(2438mm)
48"(1219mm)
STANDARD ROW CONFIGURATIONS
F IXT UR E
L E NG T H
4'
4'
1
8'
12'
8'
12' 16' 20' 24' 28' 32' 36' 40' 44' 48'
1
2
1
1
1
2
2
1
1
2
3
2
1
2
3
4
52' 56' 60' 64' 68'
2
1
3
4
5
2
1
4
5
72' 76' 80' 84' 88' 92' 96' 100' 104' 108'
6
2
1
5
6
7
Specifications and Dimensions subject to change without notice.
Corelite • 18001 E. Colfax Ave. • Aurora, CO 80011 • 303.393.1522 • FAX 303.393.1477
2
1
6
7
8
2
1
7
8
9
ADE032235
01/20/2009 1:01:01 PM
Download